User Manual 3050510
User Manual 3050510
User Manual 3050510
User Manual
Preface
Thank you for purchasing our products. Please read through this manual before using this
product so as to operate the product properly.
The GSM alarm system adopts the newest GSM network and Digital Signal Processing
Technology, and it is widely used in security field. With SMS data transmission and voice
platform of GSM network.
Perfect structure, convenient installation, easy operation with wireless control keyboard
are designed for the idea of people-oriented, which will make you feel easy and
comfortable while use this system. You only need to install the different sensors on the
door or window,and preset necessary data on the panel. When any sensor is activated
under arm status, the system will call and send SMS to owner’s telephone number
immediately. What you need is to insert a local SIM Card which supports Call ID function
and 2G network
Note: More and more people are using 3G/4G sim card, please consult with your local
SIM carrier whether it can be compatible to previous 2G network. If yes, this kind of 3G/4G
SIM card can be used in our system.
1
Contents
I.Brief function....................................................................................................................3
2.About the main panel……......……….........……..............................…...............…..........4
3.Front function instruction……….....................….....….....................................................4
4.Back function instruction ………......………...................……............................…...........4
5.Wire terminal diagram………......………...................…….........................….......…........5
6.External siren volume adjustment………...................…….......................…........…........5
7.Tone of arm and disarm setting………......……….................................…............…........5
8.Telephone alarm numbers setting………......………............................…............….........6
9.GSM network signal inquiry…...................……............................…................................7
10.Zone type setting...………...................……........................…......…..............................7
11.Delay alarm time setting…......………...................……............................…......….........8
12.Delay arm time setting…......………...................……...............................…......….........8
13.Password protection enabled.……......………...................……................….....….........8
14.Operation Password…......………...................……..................................….....….........8
15.Coding /deleting remote control .………...................……......................….....…..........9
16.Coding /deleting wireless sensor ............……..............................…................…..........9
17.Call in ring times setting……......………................……..........................….....…...........9
18.New password setting......………....................……..........................…........................10
19.System reset……......………...................……............................…..............................10
20.Record setting……......………...................……..........................…...................….......10
21.System time setting………......………....................……..........................…....…..........10
22.Timely disarm setting.………......……................……............................….....…...........11
23.Zone name edited by SMS………......….............……..........................….........…........11
24.Zone name designation……......………...................……........................….......….......11
25.Power failure/recovery SMS alert…......………...................……..................................12
26.Disarm/Arm by SMS…......………...................……......................................................12
27.System status Query by SMS…......………...................……........................................12
28.12V voltage output start/stop by SMS…......………...................……...........................12
29.Handling the call alarm…......………...................……..................................................12
30.Remotely control by call…......………...................……................................................13
31.Understanding for CID protocol network …......………...................……......................13
32.Understanding for wire sensor connection…......………...................……....................14
33.Understanding for mark on LCD …......………...................……...................................15
34.Understanding for basic wireless accessories …......………...................……..............17
35.Maintenance…......………...................……..................................................................19
2
Brief Function
1.Built-in Newest GSM MODULE from famous supplier SIMCOM with
850/900/1800/1900MHZ frequency
2.Large LCD English blue back-light display, voice prompt, ease of use
3.With 99 wireless zones+4 wired zone totally
3. Preset max 6 group of alarm numbers, and program them freely to alarm with call only,
or SMS only, or call+SMS
4.User can set zone type itself to 24hours alarm zone, burglarproof zone, delay alarm
zone, home arm zone, Multi checked zone, Delay alarm zone, Bypass zone, Repeat
triggered zone
5.Record a 10 second voice with alarm information in the host, played after user answer
the alarm call
6.It can be compatible to CID protocol
7.Auto switch to built-in back up battery for external AC power failure
8.5 group of timely arm/disarm
9. SMS alert when AC power lost or recovered
10. Customized zone name freely by user via SMS
Specification
Rated Voltage: 9~12VDC 1A
Standby current: 30-40mA
Siren Output Voltage: 12VDC
Working temperature: -10℃~+55℃
Humidity: ≤ 95% (no condensation)
Stand-by power consumption: ≤0.6W
Alarm response time:less than 8s
The volume of siren :more than 115db
3
About the main panel
The main panel should be installed in the center of prevent place which could receive the
signal very well from all wireless sensors. Please attention to keep the main panel away
from metallic objects, steel-reinforced concrete, fireproof door, home appliance or any
electricity device with high frequency interference
1.Front instruction
2.Back instruction
4
3. Wire terminal diagram
Initialization
Please insert the prepaid SIM card carefully at the back of main panel,and then plug in AC
power.( If you want to recharge the back up battery, you need to switch on firstly and then
plug in AC power)
The LCD display will show [F5]→[F6]→[Signal strength ] one by one after you power on
the system. It means the system is connected to GSM network. And the GSM LED
indicator will flash slowly 1 time every 3 seconds
System setting
All the settings can be carried out under the disarmed status with a long ‘DI’
for all the proper operations. while two short sounds for wrong settings
5
4.Telephone alarm numbers setting
User can preset max 6 groups of telephone alarm number,which the
system will auto dial or send SMS to after alarm happened
Command on the main panel: [#]→[X]→[telephone number]→[#]
X=1: The 1st telephone alarm number
X=2: The 2nd telephone alarm number
X=3: The 3rd telephone alarm number
X=4: The 4th telephone alarm number
X=5: The 5th telephone alarm number
X=6: The 6th telephone alarm number
Example: #118200986586# to set 18200986586 as the 1st telephone alarm number
6
It means that the latest log is emergency alarm
You will see the strength number on the LCD. If the number is less than 10, it means
signal is bad. If the number is more than 30, it means no GSM signal. Bigger number
means stronger signal for the numbers between 10 and 30
Wireless/wire zones wireless zone 1-wireless zone 98 useless useless 4 wire zone
7
Example: If you want to zone 15 to be home alarm type: [#]→[8]→[15]→[2]→[#]
14.Operation Password
The panel will require user to input password before any operation if user
enable the password protection
Command:[*]→[A]→[*]
A=password, 4 digits. The defaulted password is 0000
8
15.Coding /deleting remote control
Coding: User can press the command on the main panel, and trigger the signal out within
10 seconds by press any button on the remote control. You will hear a
long DI sound to show coding successfully and LCD display showing 01.
If you want to code second remote control, you can operate with the
same way, and LCD display will show 02 accordingly
Command: [*]→[0]→[*]
Deleting: User can press the command on the main panel, You will hear a long DI sound
to show ALL remote control will be deleted successfully
Command: [*]→[0]→[2]→[*]
Deleting: User can press the following command on the main panel, You will hear a long
‘DI’ sound to show deleting successfully
Command: [#]→[8]→[A]→[6]→[#]
A= zone number with 2 digits: 01,02,03,.....10......98.
Example: we need to delete the wireless door sensor at zone 05. We can do like this:
Press command [#]→[8]→[05]→[6]→[#] on the main panel. You will hear a long DI sound
to show deleting successfully
Note: If we want to delete all wireless sensors for all zones, we can press command
[#]→[8]→[99]→[6]→[#]
9
19.New password setting
User can modify the system with new password in the case of forgetting the
previous password
Command:[*]→[7]→[A]→[A]→[*]
A= new password with 4 digits .The defaulted password is 0000
Example: We need to modify the new password to 8585, we can press command
[*]→[7]→[8585]→[8585]→[*] on the main panel
20.System reset
All data will be cleared, except for coded sensors
Command:[*]→[8]→[A]→[*]
A= password, default password: 0000
Example: Press command [*]→[8]→[0000]→[*], the system will be reset
21.Record setting
User can record 10 seconds voice to show alarm information including
address, telephone number etc, which will be played on the alarm call
Command:[*]→[0]→[A]→[*]
A= system password
Example:Press command [*]→[0]→[0000]→[*] on the main panel firstly, and say
something within 10 seconds near to panel about 20cm. It will quit automatically when
time’s out
10
Example: Require 2 groups of timely arm at 08:30, 20:30 everyday, user can press the
command [#]→[0]→[7]→[08]→[30]→[1]→[#], and [#]→[0]→[7]→[20]→[30]→[2]→[#]
Note: if user want to cancel all timely arm, press command
[#]→[0]→[7]→[00]→[00]→[0]→[#]
11
27.Power failure/recovery SMS alert
Power failure: the system will send SMS “External power supply is disconnected, running
on battery” and show L5 on the panel.
Power recovery: Send SMS“External power supply recovery” and show L6 on the panel.
Command: [*]→[0]→[5]→[A]→[*]
A=2, enable SMS alert for power failure and recovery
A=0, disable SMS alert for power failure and recovery
12
Press “3” to close siren
Press “4” to away arming
Press “5” to disarming
Press “6” to play records
Press “7” to start12V voltage output
Press “8” to stop 12V voltage output
Press “#” to confirm and hang up automatically
Note: If the user phone is busy or not able to connect, the system will dial next call alarm
number until it is answered.
Note: when you hear ‘DI DI’ sounds when you input the password, it means the
password is wrong. You can try to input another new password. If the wrong times
is more than 3, or no any operation within 20 seconds, the system will hang up
automatically
13
1:Enable,upload alarm information, except for arm/disarm
information
0: Disable
14
most of wire sensor is with NC type
Step 3: Connect one wire of sensor to L4 port for zone 104, and the other wire to GND
port
Press “ ”button on remote controller or “ ” button on panel and the system will be
armed with BI tone and “ARMING” human voice. The system will alarm once any sensor is
triggered under the status of away arm
15
2.Home arm
Press “” button on remote controller or “ ” button on panel, the system will be home
armed with BI tone and and “intelligent defenses” human voice. The system won’t alarm
for trigger at home arm zone under the status of home arm
3.Emergency alarm
Press “ ”button on remote controller 1 time, the system will show 99 flashing on the LCD
display, and also start calling/SMS with silence. But if you press “ ” button again, the
siren will start at once
Press “ ” button on the main panel, the system will start calling/SMS with siren sound
and “emergency alarm” human voice
The system will alarm at once for any trigger at emergency zone no matter what it is
armed or disarmed
4.Disarm
Press “ ” button on remote controller or “ ” button on panel and the system will be
armed with BI BI tones or “DISARM” human voice. The system won’t alarm for any trigger
under the status of disarmed, except for emergency alarm
16
Understanding for basic wireless accessories
1.Wireless remote control
To control the alarm host to arm and disarm
With the emergency key for emergency help
Operating power: 27A 12V alkaline battery
Emitting distance: ≥100m (on the open area)
Battery life: ≤1 year
17
3.Infrared detector installation
Mainly monitor and control indoor space, generally set as home alarm
zone.
When human body enters into detecting area, the sensor will transmit
signals to the alarm host.
Operating power: 9V alkaline battery
Emitting distance: ≥100m (on the open area)
Battery life: ≤1 year for normal frequency
Detecting distance: 110° 10×10m
Installation height :2.2meters
18
How to let siren work with system?
Firstly, plug in or switch on the battery of siren, you will see siren flashing
quickly, which last only 6 seconds
Secondly, Press DISARM button on the system panel to send signal out
within 6 seconds after siren flashing quickly
Thirdly, The siren will flash slowly after accepting the signal, and start
alarming
Finally, user can press DISARM button again to stop siren alarming
Maintenance
Alarm system are in use everyday, but must also conduct regular maintenance periodic
testing. In order to ensure the alarm system works well, the main panel needs to
comprehensive detection every 3 months, detectors tested monthly
Host checking
1.Arm/disarm normally or not
2.Whether it can call or SMS after trigger sensor
3.Whether it can receive the signal from the sensor normally
4. Check regularly whether enough money in the SIM card
Sensor checking
1. Trigger detector by hand, check whether it can be triggered or not
2. Check the batteries every 3 months
Note
Don’t dismantle,repair or renovation products, otherwise any accidents happened
Don’t open the alarm system without permit for warranty items.if there is any questions
about the operation, don’t hesitate to contact your local seller or manufacture by email.
We or our agent will response to you within 24 hours
Thanks for your kind reading, and sincerely you will have a good time with our system
protection
19
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:(1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.