Part Number: 8103

RS-232/422 Low Cap, #24-3pr, FPO, O/A Foil+Braid, PVC Jkt, CM, 100Ω

Product Description
Computer EIA RS-232/422 Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) +
tinned copper braid shield (65% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.

Technical Specifications

Physical Characteristics (Overall)

Conductor

AWG Stranding Material No. of Conductors No. of Pairs

24 7x32 TC - Tinned Copper 6 3

Conductor Count: 6

Conductor Size: 24 AWG

Insulation

Material Material Trade Name Nominal Wall Thickness

FPE - Foamed Polyethylene Datalene® 0.013 in

Color Chart

Number Color

1 White/Blue & Blue/White

2 White/Orange & Orange/White

3 White/Green & Green/White

Outer Shield Material

Type Layer Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D

Tape 1 Aluminum/Polyester Beldfoil® 100 % TC - Tinned Copper 24 7x32 mm

Braid 2 TC - Tinned Copper 65 %

Outer Jacket Material

Material Nominal Diameter Nominal Wall Thickness

PVC - Polyvinyl Chloride 0.283 in 0.035 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR Nominal Outer Shield DCR

24 Ohm/1000ft 3.8 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield

12.5 pF/ft 22 pF/ft

Impedance

Nominal Characteristic Impedance

100 Ohm

High Frequency (Nominal/Typical)


Nom. Insertion Loss

7 dB/100m

Delay

Max. Delay Skew Nominal Velocity of Propagation (VP) [%]

78 ns/100m 78 %

Current

Max. Recommended Current [A]

1.5 Amps per conductor @ 25°C A

Voltage

UL Voltage Rating

30 V RMS (UL AWM Style 2919)

300 V RMS

Temperature Range

UL Temp Rating: 80°C (UL AWM Style 2919)

Operating Temp Range: -30°C To +80°C

Mechanical Characteristics

Bulk Cable Weight: 39 lbs/1000ft

Max Recommended Pulling Tension: 38.5 lbs

Min Bend Radius/Minor Axis: 3 in

Standards

NEC/(UL) Specification: CM

CEC/C(UL) Specification: CM

UL AWM Style: 2919 (30 V 80°C)

CPR Euroclass: Eca

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2003/96/EC (BFR): Yes

EU Directive 2011/65/EU (ROHS II): Yes

EU Directive 2012/19/EU (WEEE): Yes

EU Directive Compliance: EU Directive 2003/11/EC (BFR)

EU CE Mark: Yes

EU RoHS Compliance Date 2004-01-01


(yyyy-mm-dd):

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 UL Loading

UL voltage rating: 30 V RMS (UL AWM Style 2919)

Plenum/Non-Plenum

Plenum (Y/N): No

Plenum Number: 88103

Part Number

Variants

Item # Color Footnote

8103.0030 Chrome

8103.00305 Chrome

8103.01152 Chrome

8103.013048 Chrome

8103 060100 Chrome

8103 0601000 Chrome C


8103 06010000 Chrome C Y

8103 060500 Chrome C

8103 0605000 Chrome C

Footnote: C - CRATE REEL PUT-UP.

Footnote: Y - FINAL PUT-UP LENGTH MAY VAR -10% TO +20% FROM LENGTH SHOWN. MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.

Product Notes

Datalene« insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush
Notes:
resistance and light weight.

© 2019 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.