Skill Lab Specifications
Skill Lab Specifications
Skill Lab Specifications
Technical Specification
2. Should have manual mechanical birthing system to enable the user to control the
rotation and speed of fetus delivery etc.
3. The abdominal palpation mannequin should have an articulating full-term fetus with
palpable fontanelles, spine, shoulders, elbows, and knees with adaptors to fit with
manual birthing system.
4. Should be versatile to change the position of the fetus during the process of birth
including descend, flexion, extension, internal and external rotation, restitution.
5. The abdominal palpation mannequin should have upper and lower inflatable
cushions with independent inflating devices in the abdominal part of the mannequin •
Lower cushion when inflated should raise the fetus to desired position • Upper cushion
when inflated should create a firm abdomen as in the ninth month of pregnancy
6. Shall have adaptive birth canal to demonstrate dystocia and deal with its relief
9. Should have cervical dilatation attachment for closed os, 4cm, 6cm, 8cm and fully
dilated cervix
10. Should have features simulating/represent conditions of the cervix and vagina prior
to labor, during labor and at birth in a primgravida woman
11. The abdominal mannequin should be able accommodate the fetus in vertex, breech,
or transverse positions.
12. The abdominal mannequin should have the facility to accommodate the fetus of
different gestationalage, demonstrate vertex / Breech / transverse position delivery, and
attach the perineum to demonstrate the episiotomy repair.
13. List of training scenarios which should be there: • Normal delivery • Abnormal
labour and other complicated deliveries • IUCD Insertion • Bleeding • Urine bladder
catheterization • Uterine massage • Uterine compression • PPH and communication
training
17. Perineum and labia should be soft for realistic anatomical examination
18. List of accessories which should be there: • Detachable Manual mechanical birthing
system with mounting flange • One fully articulating fetal baby with adaptors to fit with
manual birthing system • Elevating cushion for Leopold manoeuvres • 6 detachable
dilating cervices • 6 detachable Vulva • 9 vulvar inserts • 6 placentas • 9 umbilical cords
• One 48hour postpartum uterine activity assembly • One postpartum perineal insert •
Reusable episiotomy repair module (set of 5 including median tears, mediolateral tears
and standard • mediolateral episiotomy) • 10 – 12 Weeks Pregnant • 14 – 16 Weeks
Pregnant • 2 sets cervical dilatation attachment for closed os, 4cm, 6cm, 8cm and fully
dilated cervix • Manikin should come with carry bag
Technical Specification
Manikin should be used for accurate anatomical and tactile representation of the female
pelvis for diagnosis of pathologies and abnormalities. Different pelvic modules should
be changeable during the training
5.. Perineum and labia should be soft for realistic anatomical examination
Technical Specification
1. Should have hemi pelvis of adult female with anatomical landmarks like pelvic
cavity, spine etc. should have manual mechanical birthing system to enable the
user to control the rotation and speed of fetus delivery etc
2. Should have articulating fetal baby with adaptors to fit with manual birthing
system
3. Should be versatile to change the position of the fetus during the process of
birth including descend, flexion, extension, internal and external rotation,
restitution.
4. Should have features for training normal and breech deliveries
5. Should have inflatable cushions to life fetus for Leopold maneuver during
pregnancy
6. Shall have adaptive birth canal to demonstrate dystocia and deal with its relief
7. Should have features to demonstrate cord prolapsed
8. Shall allow demonstration and practice of placenta previa
9. Should have cervical dilatation attachment for closed Os, 4cm, 6cm, 8cm and
fully dilated cervix
10. Should have features simulating /represent conditions of the cervix and
vagina prior to labor, during labor and at birth in a prim gravid woman
Additional accessories:
1. One detachable padded stomach cover
2. Detachable manual mechanical birthing system with mounting flange
3. One fully articulating fetal baby with adaptors to fit with manual birthing system
4. One elevating cushion for Leopold maneuvers
5. 6 detachable dilating cervices
6. 6 detachable vulva
7. 9 vulvar inserts
8. 6 placements 9.
9 umbilical cords
10. One 48 hour postpartum uterine activity assembly
11. One postpartum perineal insert
12. Reusable episiotomy repair module (set of 3including medial tears,
mediolateraltears and standard mediolateral episiotomy
13. 2 sets cervical dilation attachment for closed Os, 4cm, 6cm, 8cm and fully
dilated cervix
Technical Specification
The manikin should be realistic in appearance with half body child torso.
The manikin should have a soft nose which can be occluded using the nose
pinch technique.
The manikin should be able to facilitate a head tilt/chin lift technique to open the
airway and have an articulating jaw to facilitate a modified jaw thrust manoeuvre.
The manikin should have visible chest raise and wireless feedback during
ventilation.
The manikin should have a disposable lower airway with an integral one-way
valve.
The manikin should have a compression clicker which provides audible
feedback.
Feedback The pediatrics BLS Torso should be able to connect with wireless
tablets, smart phones and/or LCD wired feedback providing both student and
instructor feedback.
Wireless Instructor Feedback
Software shall be available for free downloads as many times as required
providing real-time wireless feedback on compressions and ventilations It shall
be able to monitor and connect to get the live feedback from more than 5
individual BLS Torso mannequins simultaneously for group training.
It shall help provide improvement tips based on CPR performance
Compression depth, rate release, time and chest compression fraction
Indication of too little, OK or excessive ventilation volumesWireless Student
Feedback
Wireless Student Feedback Software shall also be available for free downloads
as many times as required providing real-time wireless feedback on
compressions and ventilations, students can view and monitor their own
performance for the following points
Compression Depth and Rate
Incomplete Release
Ventilation volume
It also provides with a summative feedback on the:
Overall CPR score
Improvement suggestions
CPR duration
Technical Specification
1. It should be a newborn manikin with anatomical accuracy designed for skills training
in neonatal resuscitation to focus on the critical resuscitation skills required in the first
ten (10) minutes of a newborn’s life,
4. Infant Intubation Head - real––tic life-size intubation trainer with a flexible tongue,
arytenoid cartilage, epiglottis, vallecula, vocal cords, trachea, esophagus, and simulated
lungs
5. Positioning the newborn to simulate opening the airway via head tilt, chin lift or jaw
thrust
9. Suctioning (of the nares, nasopharynx, esophagus and lungs via an ET tube)
12. The following skills can be practiced: Nose and mouth suctioning, Oropharyngeal
and nasopharyngeal airway insertion, Bag-Valve Mask Ventilation, Chest compressions,
Bilateral and unilateral (with mainstem intubation) chest rise and fall with mechanical
ventilation, Pneumothorax – needle thoracentesis left mid-axillary
13. Cardiac Features: Manual chest compression at appropriate depth (1/3 AP) and
force, Umbilical pulse – variable via manual pulse bulb
14. Circulation Features: Umbilical vein / artery access via patent umbilicus, IO access
in left and right lower leg, tibial tuberosity and medial malleolus
16. Practice care, medication administration and removal Stomach reservoir to allow
fluid return
18. It should be supplied with: Newborn Manikin Meconium Module Set, Replaceable
Umbilical Cord (1) and clamp, IV Bag Connector Tube, Pulse Bulb (manual umbilical
pulse), Airway Lubricant, Blood Concentrate, Baby Powder, IO Fill/ Empty Syringe,
Baby Pants, Manual and Carry Case.
5.Mannequins for Urine Catheter insertion
Technical Specification
Manikin simulator must have a life-size adult female pelvis with interchangeable
male genitalia.
Urologic and rectal access gastrointestinal care procedures must be practice-
able on manikin.
Manikin should have realistic articulation which enables proper positioning for
procedures
Male and female genitalia, both must be usable with urinary connectors and
reservoir
Manikin genitalia must be used with anal connectors and colon reservoir
Urologic care procedures such as perineal insertion of vaginal medications and
indwelling catheter insertion, care, irrigation and removal must be practice able
on manikin genitalia when used with urinary connectors and reservoir
Enema administration can be facilitated using fluid for realistic return when
manikin genitalia is used with anal connectors and colon reservoir
Manikin abdominal plate must have single plug valve and interchangeable stoma
site
Simulation of cystostomy tube care and urinary diversion stoma care must be
practiced on manikin.
Reservoir can be pressurized during urinary catheterization procedures
Bilateral thigh, dorsal gluteal, and ventral gluteal IM injection must be practice
able on manikin
It should be ISO certified.
Adult female pelvis with upper thighs Male and female genitalia with six (6) anal
and urinary connectors Carry Case
Technical Specification
4. Should have Transparent structures to allow the trainer to observe and access
traineecompetence
7. Should be Latexfree
8. 2 perioperative openings represented by: Small, shallow fixed cylinder for tying in a
smallopening
9. Large, deep removable cylinder, reversible for angled abdominal and gynecological
depthtying
10. Skills to be gained using this model: One-handed reef knot technique, Instrument
tie, Surgeon’s knot slip knot, tying in a small opening, tying at depth vertically in a large
opening, Tying at depth, at an angle, in a largeopening
Technical Specification
1. The material of mannequin should be of polyvinyl or silicone rubber, free from any
hazardous materials.
2. The texture of the mannequin should be as close to the feel of the baby/adult skin as
relevant.
4.Intramuscular injection training model should have lifelike human torso with
intramuscular injection site in upper outer quadrant of palpable gluteal region on both
side(left and right)
5.Should have intramuscular injection in ventro gluteal site below iliac crest on both
side(left and right)
6.Dimension:60X60X30CM
Technical Specification
5. Arm reproductions must have replaceable skin and multi vein system to ensure
longevity of training arm
9. Palpable veins should have ability to enable site selection and preparation
10. Infusible veins must allow peripheral therapy with IV bolus or push injection method.
Technical Specification
Definition:
1.1 Clinical purpose:It is used to demonstrate nose pinch required for ventilation
techniques. Head tilt/chin lift and jaw thrust allowing students to currently practice all
manoeuvres necessary when resuscitating a real victim.
2. TECHNICAL CHARACTERISTICS
1. The material of mannequin should be of polyvinyl or silicone rubber, free from any
hazardous materials.
2. The texture of the mannequin should be as close to the feel of the baby/adult skin as
relevant.
4. It should have features to demonstrate opening of airway, head tilt/chin tilt and jaw
thrust techniques.
7. Adult CPR mannequin should have an indicator which confirms correct chest
compression technique.
2.2 Settings
3. PHYSICAL CHARACTERISTICS
3.3 Configuration
4.4 Protection NA
mannequin wipes.
8.2 Requirements for sign-off Demonstration to the users while delivering the product.
Technical Specification
This manikin should focus on complete BLS training, where students learn quality
CPR with real-time feedback from the manikin, BLS Protocol.
The training system should have facility to get connected to a hand held control
device for real-time CPR performance feedback with ventilation and compression
as per AHA 2015 guidelines.
The training system should allow further AHA and European resuscitation council
guidelines to improve feedback with quality.
Features:
1. The manikin should be a full body adult CPR training manikin with anatomically
correct landmarks and sternal notch allow the students to practice identification of all
anatomical landmarks relevant to adult CPR.
3. The manikin should stimulate natural obstruction of the airway allows students to
learn the important technique of opening the airway according to ILCOR guidelines.
Occluded airway with hyperextension stresses proper head position.
4. Head tilt/chin lift and jaw thrust allows students to correctly practice airway
manoeuvres necessary when resuscitating a real victim.
• Mouth to Mouth
• Mouth to Nose
6. The manikin must show a realistic chest rise during ventilation. The manikin should
have disposable airways and easily removable face skin to avoid cross contamination.
7. The feedback system should be wireless and a graphical user interface. Feedback
should compile following features: ¾ Compression Depth ¾ Compression release
(recoil) ¾ Compression frequency/score. ¾ Ventilation tidal volume/score ¾ Ventilation
frequency/score. ¾ Correct hand placement. ¾ Session time.
8. Adjustable limits/thresholds for compression and ventilation (default set to Guidelines
G2015)
9. Simple to use software for PC that measures the quality of CPR, providing real-time
and summative feedback on compression rate, depth, release, hands-off time and other
critical components of high quality CPR as defined in the American Heart Association
Consensus Statement.
Technical Specification
1.The Manikin should allow for high- quality airway management with supraglottic
airway device.
9. Brachial pulses & Radial Pulses : Pulse strengths dependent on blood pressure,
11. Control physiological responses Scenario event registration & detailed event log.
12. Intutive touchscreen interface to run both preprogrammed andcustom scenarious for
standardized training.
20. Voice lung ( Crackles , Pneumonia, Stridor, Wheeze, Rhonchi) and heart ( aotic
Stenosis, Friction Rub Austin Flint Murmur ,Diastolic, Murmur) sound for basic sound
training
21. Detailed information about chest compression and release compression rate ,
ventilation volume feedback to measure and improve CPR performance.
24. Voice , lung and heart sound for basic sound training
25. Detailed information about chest compression and release, compression rate,
ventilation volume feedback to measure and improve CPR performance
Technical Specification
The First Aid Training Manikin is a lifelike full-body adult manikin designed for
teaching used for teaching CPR and First Aid through the use of realistic
interchangeable wound modules.
Wound Modules
Technical Specification
1. Manikin should be having latex free material and also having soft tissues for real like
look
3. Hard torso should be supplied with manikin as a standard package for bench top use
4. Pathologies should be changeable and should be placed in various predetermined
location points
5. Clavicular & axilla pads should be there for lymph node placement
7. Skills should be gained: - Clinical breast examination techniques (CBE & SBE) -
Professional-to-patient communication - Identification of anatomical landmarks & lymph
nodes (axillary, supra & infraclavicular) - Location & diagnosis of pathologies
12.Trauma mannequin
Technical Specification
The Manikin should be a superior trauma and extrication manikin with three
interchangeable heads: standard and trauma intubation heads and fracture
Head. It should come with a wide range of trauma wound modules to enhance
scenarios.
Features:
Fracture head facilitates facial and cranial trauma assessment including an open
depressed skull fracture, deviated trach, bilateral mandible fractures, and fracture
of the C6 vertebrae.
Standard intubation head should allow airway management by manual
maneuvers and various airway devices.
Trauma intubation head should have an impaled object in the cheek, avulsed
ear, unequal pupils, broken teeth and multiple lacerations.
Interchangeable bullet wound chest module for assessment and care.
Full body manikin can be used for extrication and triage exercises.
Realistic articulation for application of cervical collars, splints and traction, or
application to spine board.
Complete trauma module se to add realism to training scenarios.
Carry case is provided for storage and transportation.
Technical Specification
2. Should have soft and flexible and replaceable face skin and upper body skin