Primary Loads
Primary Loads
Primary Loads
I N P U T R E C O R D STRUCTURE CALCULATION
================================
PIPELINE NAMES
--------------
Line Node1 Node2 Pipeline
L i n e 1
L i n e 2
L i n e 3
L i n e 4
168.3 4.50 150 1.0 7850 130 2700 1000 18.2 23.5 19.9 61.6
Line 1
869 ~014 168.3 4.5 0.6 0.0 61.6 110.0 7.3 P235GH UL
~014 872 168.3 4.5 0.0 0.0 61.6 110.0 7.3 P250GH UL
873 ~015 168.3 4.5 0.0 0.0 61.6 110.0 7.3 P250GH UL
~015 $000 168.3 4.5 0.6 0.0 61.6 110.0 7.3 P235GH UL
$000 867 168.3 4.5 0.6 0.0 0.0 110.0 7.3 P235GH UL
Line 2
600 896 168.3 4.5 0.6 0.0 61.6 110.0 7.3 P235GH UL
Line 3
895 642 168.3 4.5 0.6 0.0 61.6 110.0 7.3 P235GH UL
Line 4
866 $001 168.3 4.5 0.6 0.0 0.0 110.0 7.3 P235GH UL
$001 ~013 168.3 4.5 0.6 0.0 61.6 110.0 7.3 P235GH UL
~013 871 168.3 4.5 0.0 0.0 61.6 110.0 7.3 P250GH UL
870 ~012 168.3 4.5 0.0 0.0 61.6 110.0 7.3 P250GH UL
~012 868 168.3 4.5 0.6 0.0 61.6 110.0 7.3 P235GH UL
Bertha-von-Suttner-Allee 19, D 59423 Unna Rohrstatikberechnungen
Telefon: +49 (0)2303 332 33-0 mit dem Programm
Fax: +49 (0)2303 332 33-50
Software & Engineering Email info@rohr2.de - Internet www.rohr2.de ROHR2
I N P U T S -- Program ROHR2 /33.1 -- Page 7
Commiss. Messe München GmbH Date 30.08.22 20:50:12
022008 Notfallheizung Variante 1.3 - Ost
Line 1
872 873 R186.3X13.5 Zp in +Za 1 0.0 198.83 P235GH UL
Line 4
871 870 R186.3X13.5 Zp in +Za 1 0.0 198.83 P235GH UL
L O A D C A S E Primary loads
---------------------------------
Line 1
869 ~014 P235GH 110.0 20.0 205.3 0.00 7.30 .300
~014 872 P250GH 110.0 20.0 205.3 0.00 7.30 .300
872 873 P235GH 110.0 20.0 205.3 0.00 7.30 .300
873 ~015 P250GH 110.0 20.0 205.3 0.00 7.30 .300
~015 $000 P235GH 110.0 20.0 205.3 0.00 7.30 .300
$000 867 P235GH 110.0 20.0 stiff 0.00 7.30 .300
Line 2
600 896 P235GH 110.0 20.0 205.3 0.00 7.30 .300
Line 3
895 642 P235GH 110.0 20.0 205.3 0.00 7.30 .300
Line 4
866 $001 P235GH 110.0 20.0 stiff 0.00 7.30 .300
$001 ~013 P235GH 110.0 20.0 205.3 0.00 7.30 .300
~013 871 P250GH 110.0 20.0 205.3 0.00 7.30 .300
871 870 P235GH 110.0 20.0 205.3 0.00 7.30 .300
870 ~012 P250GH 110.0 20.0 205.3 0.00 7.30 .300
~012 868 P235GH 110.0 20.0 205.3 0.00 7.30 .300
Bertha-von-Suttner-Allee 19, D 59423 Unna Rohrstatikberechnungen
Telefon: +49 (0)2303 332 33-0 mit dem Programm
Fax: +49 (0)2303 332 33-50
Software & Engineering Email info@rohr2.de - Internet www.rohr2.de ROHR2
I N P U T S -- Program ROHR2 /33.1 -- Page 9
Commiss. Messe München GmbH Date 30.08.22 20:50:12
022008 Notfallheizung Variante 1.3 - Ost
Acceleration loads
------------------
The system mass data and the following accelerations are used
to calculate static loads, which are applied on the system:
======================================================================
S U M M E D V A L U E S for checkup
R E S U L T S STRUCTURE CALCULATION
=============================
L O A D C A S E Primary loads
==================================
L i n e 1
L i n e 2
791 -793 -0.1 0.3 0.2 -0.05 1.27 -0.15 1.24 20.1
793 v AR -0.1 0.3 0.0 -0.05 1.27 -0.15 1.24 20.1
793 n AR -0.1 0.3 -0.0 -0.05 2.60 -0.15 1.24 20.6
879 v PT -0.1 0.3 -0.3 -0.05 2.27 -0.15 0.13 14.0
879 n PT -0.1 0.3 -0.3 -0.05 2.27 -0.15 0.13 14.0
867 v PT -0.1 0.2 -0.4 -0.05 2.18 -0.15 0.44 14.8
867 n PT -0.1 0.2 -0.4 -0.05 0.80 0.28 0.44 15.0
880 v PT -0.1 0.2 -0.5 -0.05 0.71 0.28 0.55 15.5
880 -~020 -0.1 0.2 -0.8 -0.05 1.06 0.28 0.97 18.1
889 v Elb -0.1 0.1 0.0 -0.05 1.06 0.28 0.06 14.1
889 m Elb -0.1 0.1 0.2 -0.05 1.16 0.16 0.35 19.0
889 n Elb -0.1 0.1 0.1 -0.03 1.27 -0.21 0.56 15.5
894 v AR -0.0 0.1 0.0 -0.03 1.42 -0.21 0.88 17.3
894 n AR -0.0 0.1 0.0 -0.03 1.36 -0.21 0.88 17.3
891 v Elb -0.0 0.1 -0.8 -0.03 0.82 -0.21 0.11 14.1
891 m Elb -0.0 0.1 -0.9 -0.05 0.71 -0.28 0.06 14.3
891 n Elb -0.0 0.1 -0.9 -0.05 0.60 -0.28 0.07 14.1
896 v ST 0.0 0.0 -0.0 -0.05 1.29 -0.28 1.14 19.5
L i n e 3
L i n e 4
Point Op
WX WY WZ(mm) AQX AQY AQZ(kN)
PX PY PZ(deg) AMX AMY AMZ(kNm)
L i n e 1
869 ST
0.00 0.00 0.00 -0.000 -0.037 0.766
0.00 -0.03 0.00 0.000 0.000 0.000
875 AR
-0.04 -0.00 -0.00 0.000 0.000 -4.053
-0.02 -0.03 0.00 0.000 0.000 0.000
L i n e 2
600 ST
0.00 0.00 0.00 0.046 0.011 -1.405
0.00 0.00 0.00 1.336 0.126 0.116
791 AR
-0.05 0.22 -0.00 0.000 0.000 -2.446
0.01 0.02 -0.00 0.000 0.000 0.000
793 AR
-0.05 0.27 -0.00 0.000 0.000 -3.875
0.04 -0.03 0.00 0.000 0.000 0.000
894 AR
-0.04 0.08 -0.00 0.000 0.000 -2.778
-0.04 0.02 -0.00 0.000 0.000 0.000
Bertha-von-Suttner-Allee 19, D 59423 Unna Rohrstatikberechnungen
Telefon: +49 (0)2303 332 33-0 mit dem Programm
Fax: +49 (0)2303 332 33-50
Software & Engineering Email info@rohr2.de - Internet www.rohr2.de ROHR2
R E S U L T S -- Program ROHR2 /33.1 -- Page 13
Commiss. Messe München GmbH Date 30.08.22 20:50:12
022008 Notfallheizung Variante 1.3 - Ost
Point Op
WX WY WZ(mm) AQX AQY AQZ(kN)
PX PY PZ(deg) AMX AMY AMZ(kNm)
896 ST
0.00 0.00 -0.00 -0.046 0.026 -1.287
-0.00 -0.00 -0.00 -0.281 1.134 0.053
L i n e 3
895 ST
0.00 0.00 0.00 -0.070 0.028 -0.596
0.00 0.00 0.00 0.753 -0.356 0.032
893 AR
-0.03 0.01 -0.00 0.000 0.000 -3.063
0.17 -0.00 -0.01 0.000 0.000 0.000
794 AR
-0.12 0.47 -0.00 0.000 0.000 -3.751
0.09 -0.06 0.00 0.000 0.000 0.000
792 AR
-0.12 0.60 -0.00 0.000 0.000 -3.087
0.06 0.07 0.00 0.000 0.000 0.000
642 ST
0.00 -0.00 -0.00 0.071 0.013 -1.740
0.00 -0.00 -0.00 1.997 0.329 0.230
L i n e 4
874 AR
-0.09 -0.00 -0.00 0.000 0.000 -3.895
-0.02 -0.07 0.00 0.000 0.000 0.000
868 ST
-0.00 -0.00 -0.00 -0.000 -0.041 0.650
0.00 -0.07 0.00 0.000 -0.000 -0.000
Point Op
DWX DWY DWZ(mm) QX QY QZ(kN)
DPX DPY DPZ(deg) MX MY MZ(kNm)
L i n e 1
L i n e 4
SIGMA PKT