1-24-150 / Exp lo s io n/flame p ro o f s ignals

GNExCP7-BG Break Glass Manual


Call Point
The GNExCP7-BG break glass Ex d explosion proof manual call points feature
a robust GRP enclosure with a 316 stainless steel mechanism and IP66/67
rating – manufactured for the harshest of hazardous environments.
Glo bally appro ved to IECEx, ATEX, UL and cUL standard fo r all Z o ne 1, 2, 21 & 22 and Class I/II
Div 2 installatio ns. Can also be specified fo r applicatio ns requiring co mpliance to the UL38
standard fo r Manual Signaling Bo xes fo r Fire Alarm Systems o r ULC-S528 Manual Statio ns Fo r Fire
Alarm Systems. Available with DIN rail terminals o r the inno vative E2S terminatio n bo ard with
dedicated co nnectio ns fo r field installed EOL and/o r series devices. SIL 2 co mpliant to IEC 61508
(2010).

Features
Corrosion proof GRP enclosure, anti-static & UV stable
Ingress protection IP66/67, 4/4X/3R/13
Single or double switch (SPCO/DPCO)
316 (A4) stainless steel mechanism
Optional stainless steel lift flap
3 x cable entries, 2 x stopping plugs included
Captive stainless steel fasteners

Ap p ro vals
UL/cUL certificate: 20190604-E482536, 20200224-E513632
IECEx certificate: IECEx ULD 19.0007X
ATEX certificate: DEMKO 19 ATEX 2101X
UKCA certificate: UL21UKEX2134X
SIL 2 compliant to IEC 61508 (2010)

C o d ing
NEC / CEC:
Class I Div 2 Group ABCD T5 Ta -55°C to +70°C *
Class I Div 2 Group ABCD T6 Ta -55°C to +60°C
Class II Div 2 Group FG T4 Ta -55°C to +60°C #
Class III Div 1 & 2 Ta -55°C to +60°C #
NEC:
Class I Zone 1 AEx db IIC T5 Gb (Ta -55°C to +70°C) *
Class I Zone 1 AEx db IIC T6 Gb (Ta -55°C to +60°C)
Zone 21 AEx tb IIIC T135°C Db (Ta -55°C to +70°C) *
Zone 21 AEx tb IIIC T125°C Db (Ta -55°C to +60°C)
CEC:
Class I Zone 1 Ex db IIC T5 Gb X (Ta -55°C to +70°C) *
Class I Zone 1 Ex db IIC T6 Gb X (Ta -55°C to +60°C)
Zone 21 Ex tb IIIC T135°C Db (Ta -55°C to +70°C)
IECEx & ATEX:
II 2G Ex db IIC T5 Gb Ta. -55 to +70°C
II 2G Ex db IIC T6 Gb Ta. -55 to +65°C
II 2D Ex tb IIIC T90°C Db Ta. -55° to +70°C
*: F version only
#: F version +70°C
See product manual for full product specific coding.
S p ecif icatio n Part C o d es
GNE xCP 7 -BG: Break Glass Manual Call Point P ar t
Ver si on : D esc r i p ti on :
Temp. Range: -55°C to +60°C/+70°C r ef er en c e:
Product type: GNExCP7BG Break Glass Manual Call Point
Ingress protection: IP66/67 to EN/IEC 60529
4/4X/3R/13 to UL50E/NEMA250 Switch type: [s] S SPCO/SPDT
D DPCO/DPDT
Enclosure matl: GRP Glass Reinforced Polyester, anti-static & UV stable
Terminals: [t] D DIN Rail 8 × SAK2.5
Colour: Red P Termination board: 6 × 2.5mm² terminals plus
Other solid and striped colours available 4 × EOL & Series terminals
Lift flap: Optional 316 stainless steel lift flap Lift flap: [l] N No lift flap
Cable entries: 2 x M20x1.5 down facing and 1 x M20x1.5 side L Stainless steel lift flap
Back box can be rotated to provide 2 x top facing and 1 x side Cable entries:[e] A 3 x M20x1.5mm
entries B 2 × 1/2" NPT – adaptors
Cable entries adaptable to 1/2"NPT, 3/4"NPT & M25 C 2 × 3/4" NPT – adaptors
Stopping plugs: 2 x Stopping plugs as standard D 2 x M25x1.5mm – adaptors
Brass, Nickel plated or Stainless Steel E 1 × 1/2" NPT – adaptor
F 1 × 3/4" NPT – adaptor
Terminals: DIN rail 8 × 2.5mm² SAK2.5 or G 1 x M25x1.5mm – adaptor
Termination board featuring 6 × 2.5mm² terminals plus 4 x
dedicated EOL & Series terminals Stopping plug B Brass
material: [m] P Nickel Plated Brass
Earth: External M5 earth connection S Stainless Steel
Relative Humidity: R.H. 95% @ 20°C Duty label / 1 No Duty label, no Equip. tag
MTBF: 479.6 years / 4,201,680 hours - MIL 217 Equipment tag: 2 Duty label Stainless Steel
[d]: 3 Duty label St/St + Equip. tag
Weight: 2.1Kg/4.63Ibs 4 Duty label Metalised Polyester
5 Duty label M. Poly. + Equip. tag
Voltage Range: Max input Current: Limitations for EOL / Series Resistors: 6 Equip. tag only
7 Special label requirement
250Vac Max 3.33A max not permitted
Product version: A UL, cUL, IECEx, ATEX & PESO
48Vdc Max 1.0A max min. 2.2kOhm [v] F UL38 & ULC-S528 Fire
24Vdc Max 3.0A max min. 470 Ohm UL, cUL, ULC, IECEx, ATEX & PESO
H Honeywell TC809B1008 module IECEx, ATEX
EOL and Series Diode Values: Z Ziton A45E-2 module IECEx, ATEX
xxx: Zener Value Max. current supply permitted M Johnson Controls MIM800 Mini module IECEx,
ATEX
3V3 3.3V Diode 230mA
Product option: [o] 1 Standard product
4V7 4.7V Diode 162mA
Enclosure colour: R Red
5V1 5.1V Diode 149mA [x] B Blue
5V6 5.6V Diode 136mA N Green
Y Yellow
6V2 6.2V Diode 122mA V Red/White
6V8 6.8V Diode 112mA S Yellow/Black
K Black
10V 10V Diode 76mA M Magenta
12V 12V Diode 63mA Z Red/Black
Default variable: N Default = N – not currently used
[u]
E.O.L.Module: [e] ExxxR Resistor value in Ohms e.g. E470R = 470 Ohm
optional ED1 Diode IN4007 = ED1
ExxxZ Zener diode e.g. E5V1Z = 5.1V
Series Module: [s] SxxxR Resistor value in Ohms e.g. S1K5R = 1.5K Ohm
optional SD1 Diode IN4007 = SD1
SxxxZ Zener diode e.g. S5V1Z = 5.1V
Note: F version only available with Duty label option 2 or 3.
Mandatory duty label: “FIRE/FEU”
F version only available with Red enclosure
H, Z and M versions are IECEx & ATEX approved only
Spares:
SP70-0001 Spare Break Glass – Box of 50
SP70-0040 Spare GNExCP7-BG Test Key
Accessories:
SP65-0001-A4 Pole Mount Bracket Kit 2" St/St A4 (316)
SP65-0002-A4 Sunshade – St/St A4 (316)
E2 S Warning S ignals s ales @ e2 s .com www.e2 s .com 9 Jun 2022
No liability is accepted for any consequence of the use of this document. The technical specification of this unit is subject to chang e without notice due to our policy of continual product development. All dimensions are approximate. This unit is sold subject to our standard
conditions of sale, a copy of which is available on request.

You might also like