New OSRAM SubstiTUBE Advanced EM T8 WV (Preliminary)
New OSRAM SubstiTUBE Advanced EM T8 WV (Preliminary)
New OSRAM SubstiTUBE Advanced EM T8 WV (Preliminary)
Advancing Light
LEDVANCE is one of the World‘s leaders in general lighting for lighting
professionals as well as end users, offering
LEDVANCE is licensee of product trademark
OSRAM for lamps products in general lighting .
• Weight: <500g
Use Benefits
innovative LED-lamp, easy and safe to use with CCG retrofit and AC direct input
Quick, simple and safe replacement. Correct operation temperature --20°C … +45°C
Application Areas:
• Train Station
• Office, School
• Underground subway
• Supermarket, retail store
• Parking lot
• Warehouse
Photo Caption 2
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
PRODUCT INFORMATION
Electrical and photometric data (rated value)
Voltage Frequenc Power Lumen CCT DF CRI
[V] y (100%) Flux(100%) [lm] [K] (Ra)
[Hz] [W]
Common Characteristics
Lifetime @L70B50 (hrs) 2 Color Rendering Index SDCM Beam Angle Operating Temp.(ºC)
(50% light intensity)
50,000 ≥ 80 ≤6 >160° -20 ~ +45
1Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical
values given above for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of
an individual product; individual product may vary from the typical values. For parameter of Lumen and Watt, production control tolerance with ±10% in
delivery.
2L70B50 is the average operating life of the LED Lamp during which the luminous flux is greater than or equal to 70% of the initial luminous flux, for 50%
of the population. The lifetime is estimated at room temperature (25deg C), free air burning, base up position.
3 TheTc is defined as the highest permissible temperature which may occur on the outer surface of the LED lamp (in the indicated position) under normal
operating conditions and at the rated voltage/current/power or the maximum of the rated voltage/current/power range (DIN EN 62031: 2009-01)
Subject to change without notice. Always make sure to use the most recent release
3
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
TECHNICAL INFORMATION
Minimum / Ambient temperature Ta Maximum temperature Tc Storage temperature Ts
[C°]
Maximum
ratings
ST8A-0.6M 7.5W -20~45°C <75 °C -20°… 80°C
100mm
Subject to change without notice. Always make sure to use the most recent release
4
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
▪ The SubstiTUBE® Advanced EM T8 Tube must be handled with care. Do not operate product in a
damaged condition.
▪ When operating with double side input wiring, SubstiTUBE® Starter has to be inserted to replace
the conventional fluorescent lamp starter. If the conventional starter is not replaced, the
SubstiTUBE® Advanced EM T8 Tube will start blinking and be damaged!
▪ Do not use SubstiTUBE® Advanced EM T8 Tube in luminaires which do not have any
conventional starter or whereby the conventional starter cannot be replaced. Otherwise,
rewiring is needed.
▪ Not suitable for luminaires with serial lamp connection i.e. more than one tube at one magnetic
ballast.
▪ The SubstiTUBE® Advanced EM T8 Tube emits light at a limited angle, unlike
conventional fluorescent tubes in 360° omni-direction.
▪ Due to the light distribution characteristic of the SubstiTUBE® Advanced EM T8 Tube the resulting
luminaires light characteristic is likely to change. It is not guaranteed that e.g. standards for lighting
at working places will be complied with after replacement. A photometric check of the installation is
highly recommended.
▪ The effective energy savings depend on the efficiency of the luminaire setup to be replaced and
should be considered individually in each case. Particularly magnetic ballast losses are reduced
to ohmic losses and are normally only about 1W.
▪ The SubstiTUBE® Advanced EM T8 Tube is protected according to IP20. Applications with
external risk of moisture and dust can be served with an adequately protected luminaire.
▪ SubstiTUBE® Advanced EM T8 Tube products differ in their diameters and geometries from
fluorescent lamps. Their use in open batten luminaires with gaskets is possible if no excessive
force is expended during the fixing. Obtaining the necessary IP protection in open batten
luminaires with gaskets cannot be ensured.
▪ SubstiTUBE® Advanced EM T8 Tube can be driven directly on line voltage. In order to grant a
safe operation mode please refer to the installation instructions for further information.
▪ Photobiological Safety of lamps and lamp systems according to IEC 62778. Risk Group: Exempt
5
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
Installation Guide
6
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
Installation Guide
SubstiTUBE® Advanced EM T8 Tube may also be driven directly on line voltage. Please check the
L/N markings on the LED tube. In order to grant a safe operation mode please refer to the
installation instructions for further information. Installation must be done by licensed electricians.
or
or
WARNING: SubstiTUBE® Advanced EM T8 Tube is not compatible for use with electronic control
gear (ECG). If there is an existing ECG, bypass the ballast and re-wire* according to “2) Installation
directly on line voltage” and diagrams above.
*WARNING: Modifications to the wiring of an existing luminaire must be carried out by qualified
personnel only. Any modifications made to the original luminaire will alter the safety aspects of
the original luminaire; hence compliance certification of the original luminaire will no longer be
applicable to the modified luminaire.
7
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
Installation Guide
Tube side with the marking “AC input” around the cap should be facing the lampholder with mains connection
otherwise the lamps will not be functionally ON, and AC line in might short circuit.
8
OSRAM SubstiTUBE® Advanced EM T8 WV (KSA) | Technical Information Preliminary version
Ordering Guide
WWW.ledvance.com
WWW.osram-lamps.com/substitube
LEDVANCE GmbH