Nothing Special   »   [go: up one dir, main page]

Abacus Challenger 2 Al5800

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

FLOODLIGHTING

CHALLENGER 2 AL5800
®

Benefits
• The Challenger 2 offers an
asymmetric reflector ideally suited
to lighting medium and larger stadia
from the side, typically from the roof
• The floodlight bears the quality
hallmarks of the Challenger
floodlight range

Technical Features
• Body of high pressure die cast
aluminium, finished in light grey
(RAL7035), polyester powder coating
• Reflector system of high purity,
polished and anodised aluminium. •E
 lectrical connection box •D
 ual provision on the side of the
Incorporating an internal baffle to (IP66) housing ignitor, located floodlight body to attach the gun
improve efficiency and reduce glare on side of stirrup, fitted with sight aiming device to allow accurate
2 x GORE™ membrane breathers beam alignment (AL5931)
• Toughened front glass, secured by
cast aluminium front frame •D
 esigned to accept double ended, •E
 asy access for re-lamping via
long arc 2kW or 1kW metal opening of the rear cover.
• Galvanised steel stirrup,
halide lamps Positive closure via large
with additional elevation
stainless steel catch
locking screws

Colorline Stadium, Norway

76 www.abacuslighting.com
Technical Specifications

FLOODLIGHTING
Beam Type Lamp: Manufacturer Product Lamp Lamp: Abacus Lampholder
Code Manufacturer Product Code Type

AL5801 Narrow 2kW: HQI-TS 2000W/N/L Osram LPW2000M/LA K12s-7


AL5802 Medium 2kW: HQI-TS 2000W/N/L Osram LPW2000M/LA K12s-7
AL5803 Wide 2kW: HQI-TS 2000W/N/L Osram LPW2000M/LA K12s-7
AL5804 Narrow 2kW: MHN-LA2KW/842 & Philips LPP2000MHN-TD (842) & XWH-UNP
956 LPP2000/D (956)
AL5805 Medium 2kW: MHN-LA2KW/842 & Philips LPP2000MHN-TD (842) & XWH-UNP
956 LPP2000/D (956)
AL5806 Wide 2kW: MHN-LA2KW/842 & Philips LPP2000MHN-TD (842) & XWH-UNP
956 LPP2000/D (956)
AL5807 Narrow 1kW: MHN-LA1KW/842 & Philips LPP1000MHN-TD (842) & XWH-UNP
956 LPP1000MHD-TD (956)
AL5808 Medium 1kW: MHN-LA1KW/842 & Philips LPP1000MHN-TD (842) & XWH-UNP
956 LPP1000MHD-TD (956)
AL5809 Wide 1kW: MHN-LA1KW/842 & Philips LPP1000MHN-TD (842) & XWH-UNP
956 LPP1000MHD-TD (956)
AL5810 Narrow 2kW: MH-TS2000W/L/K12/4K Venture LPV2000M/LA K12s-7
AL5811 Medium 2kW: MH-TS2000W/L/K12/4K Venture LPV2000M/LA K12s-7
AL5812 Wide 2kW: MH-TS2000W/L/K12/4K Venture LPV2000M/LA K12s-7
AL5813 Narrow 2kW: MH-TS2000W/XL/K12/745 Venture LPV2000MH-TS-XL K12s-7
AL5814 Medium 2kW: MH-TS2000W/XL/K12/745 Venture LPV2000MH-TS-XL K12s-7
AL5815 Wide 2kW: MH-TS2000W/XL/K12/745 Venture LPV2000MH-TS-XL K12s-7

Lamp references

HQI-TS MHN-LA
MH-TS

Lamp Manufacturer Lamp Colour RA: Lamp Lumen Lamp Supply Total
& Lamp Ref. Wattage Temp Output: Current: Voltage: Circuit
(Initial Im) Power:
Venture
MH-TS2000W/L/K12/4K 2kW 4500K 65 240,000 I.lm 10.3A 380/400/415V 2150W
MH-TS2000W/XL/k12/745 2kW 4500K 65 240,000 I.lm 10.3A 380/400/415V 2150W
Philips
MHN-LA2KW400V/842 2kW 4200K 80 220,000 I.lm 9.6A 380/400/415V 2105W
MHN-LA2K400V/956 2kW 5600K 90 190,000 I.lm 10.3A 380/400/415V 2113W
MHN-LA1KW230V/842 1kW 4200K 80 100,000 I.lm 9.3A 230/240V 1040W
Osram
HQI-TS2000WNL 2kW 4400K 65 230,000 I.lm 10.7A 380/400/415V 2180W
HQI-TS2000WDL 2kW 5400K 85 20,5000 I.lm 10.3A 380/400/415V 2180W
Technical information may alter dependent on control gear used

Professional lighting systems to suit any project. Call 01623 518 333 77
Dimensions Maintenance
Dimensions in mm

484

36
1

484
541

370 352
360 70
622

Mounting: Weight: 15Kg. Front wind area: 0.196m2 70º Easy Maintenance:
Stirrup mounted using M20 fixing max setting Access to the lamp by means
Stirrup adjustment +/- 140º of opening the rear door

Accessories

Single blade louvre – AL5922 Aiming tool kit – AL5931


This accessory for the Challenger 2 & 3 minimises Set of equipment and instructions to enable the
upward light while maintaining good vertical lighting Challenger 2 & 3 to be aimed with pinpoint accuracy
levels on the playing field to a specific point on the design area. Allows the highest
level of control over the aiming and commissioning part
of a floodlighting project

Key features

1. 0
-90º -70º -50º 30º -10º 10º 30º 50º 70º 90º 2. 0
-90º -70º -50º 30º -10º 10º 30º 50º 70º 90º 3. 0
-90º -70º -50º 30º -10º 10º 30º 50º 70º 90º
2000 1400 900

1800 800
1200
1600
700
1400 1000
600
1200
800 500
cd/klm
cd/klm

1000
600 400
800
300
600 400
200
400
200
200 100

0 0 0

AL5804 AL5805 AL5806


2kW MHN-LA2KW 2kW MHN-LA2KW 2kW MHN-LA2KW
Narrow beam Medium beam Wide beam

78 www.abacuslighting.com