Promotional Profile

For internal use only

SENTRON PAC4200
Illustration Short description

Multi-functional measuring device SENTRON PAC4200


The SENTRON PAC4200 is a digital multi-functional
measuring device for monitoring of electrical systems
and for the accurate measuring and display of all
relevant energy data of the low-voltage energy
distribution.
It delivers all data for an appreciation of net quality.

Slogan
Key electrical values and energy at a glance – reliable
and precise.

Description of application:
SENTRON PAC4200 is a power monitoring device for the collection and display of characteristic
electrical values and energy.
Performance characteristics of the PAC4200 at a glance:
• Measuring of around 200 electrical values, e.g.UL-N / UL-L / I / IN / S / ±P / ±Q / LF / power
factor / f with minimum, maximum and average values
• Meets with all requirements in accordance with IEC61557-12, the new standard for
measuring devices for the measuring and monitoring of operational behavior in power
distribution networks and systems
• Highly accurate measuring results: Class 0.2 for voltage, current, active power and active
energy
• Provision of basic data for assessment of the network quality, e.g. THD-UL-L / THD-UL-N /
THD-I / 3rd – 31st harmonics for voltage and current / distortion current strength Id / phase
angle
• Intuitive user guidance in 9 languages
• Integrated 10/100 MBit/sec Ethernet interface with autonegotiation and auto MDI(X)
• Gateway function for connection of devices with RS485 interface to the Ethernet
• Four individually configurable screen displays (bar chart or digital displays)
• Comprehensive recording functions
• Limit value monitoring with Boolean logic (AND / OR / NAND / NOR / XOR)
• Direct connection without voltage transformer up to 690VL-L (for USA: 600VL-L)
• UL and CSA approval for the USA and Canada (cULus)
• Compliance with the requirements for "type enclosure 5" in accordance with UL50
Specification; therefore suitable for application in power distribution boards designed in
accordance with the UL508 standard
Promotional Profile
For internal use only
Areas of use

Whether in industrial or infrastructure buildings, SENTRON PAC4200 supplies important


information for building services or energy controlling wherever there is a need for energy
distribution. The various communication possibilities offered by the SENTRON PAC 4200 make it
an indispensable source of data for power management systems and for general industrial and
building automation purposes

Branches:
Electrical energy, and in order to that also energy distribution systems, is required in all sectors

Communication

Ethernet on Board; 10 / 100MBit/s with auto-negotiation and auto crossover (Auto-MDI(X))

• Assistance up to 3 Modbus-TCP connections on the integrated Ethernet interface (simultaneous)


• Gateway functionality (Ethernet Modbus-TCP <=> RS485 Modbus-RTU)
• Firmware update via communication interface (Ethernet)
• Expandable with max. 1 communication module
ƒ SENTRON PAC PROFIBUS DP or
ƒ SENTRON PAC RS485 for Modbus-RTU or SEAbus

Order information

product Uc (V) Ie (A) Ue (V) frequenz order no.


(Hz)
MLFB

Power Monitoring 95…240VAC ±10% x/1A o. max.3x 45...65Hz 7KM4212-0BA00-3AA0


Device PAC4200 110…340VDC ±10% x/5A 400/690V

with compression
terminal

Power Monitoring 95…240VAC ±10% x/1A o. max.3x 45...65Hz 7KM4212-0BA00-2AA0


Device PAC4200 110…340VDC ±10% x/5A 400/690V

with ring lug terminals


Promotional Profile
For internal use only

Advantage at a glance
Unique selling points Customer value Proof
High level of accuracy Increased energy The measuring error in energy consumption
for energy; Class 0.2 in transparency in the plant recording and subsequent cost calculation
accordance with thanks to more precise becomes neglible. This means the
IEC61557-12 or 0.2S in assignment of energy PAC4200 meets the accuracy requirements
accordance with consumption to individual necessary for calculating with utility
IEC62053-22 cost centers. company meters.
Integrated Ethernet Improved system High-speed data transfer for improved
interface as standard performance, easy overall performance contributes
interface in each device adaptability to customer substantially to customer satisfaction.
applications, and thus No restrictions to system design.
reduced implementation Simple connection to the higher-level power
costs and increased management software.
customer satisfaction
Gateway function Reduced integration costs Using the integral gateway function, lower-
for devices with simple, level devices equipped with only a serial
serial RS485 interface RS485 interface (Modbus-RTU) can be
integrated into an Ethernet network at no
additional cost.
Load profile memory Increased energy The PAC4200 records power demands with
transparency, reduced associated minimum and maximum values
energy costs, increased for apparant power, active power and
plant efficiency reactive power time-synchronously with
utility company measurement. This means
plant utilization can be calculated precisely
and optimized, reducing energy costs and
increasing the effectiveness of the plant.
Event memory Increases plant availability User-adjustable, requirement-oriented
and facilitates fault analysis recording of more than 4,000 operating
events, operator input events and system
events facilitates troubleshooting in the
event of a fault. In addition, developing
faults can be detected early, allowing
suitable measures to be taken before a
failure occurs.
Integral time-of-day and Simplifies troubleshooting Troubleshooting is significantly simplified by
calendar function and thus saves time and time-related recording of minimum,
costs maximum and average values, as well as
operating events, operator input events and
system events
PAC4200 supplies Enables monitoring of To assess system quality, the PAC4200 also
power quality data as switching and protection calculates the cosPhi, the system harmonics from
the 3rd to the 31st for current and voltage,the
well as sliding window devices, transformers and distortion current strength and neutral conductor
demands for almost all cables, etc., and thus current, in addition to the THD, the unbalance, and
measured values. helps to increase plant the power factor. This data is absolutely neces-
sary in order to recognize and prevent faults in the
availability and safety
plant.

www.siemens.de/lowvoltage
© Siemens AG 2006
Änderung vorbehalten
Promotional Profile
For internal use only

Competitors Strength Weakness


Enlarge consequently the area of Power No continuous Look-and-Feel fort he devices
Monitoring and Control Slim focus on the integration of the devices in
Schneider Trendsetter, is market leader in many industry automation
regions
Family company with strong market Not represented in BR2, some extend in BR3 in
share in BR1 China
No continuous system attachment
Janitza
Slim distribution channel to the industry market
Specialization on the small area of energy
distribution product
Specialized on energy distribution with no MCCB in the portfolio and no solution for
Socomec wide portfolio industry application

Weiterführende Informationen:

Internet: www.siemens.com/powermanagementsystem

catalogue: intranet.siemens.com/lowvoltage/kataloge

technical documentation: www.siemens.com/automation/support

Technical Assistance: Telefon: +49 (911)-895 5900


Fax: +49 (911)-895 5907
Email: technical-assistance@siemens.com

contacts in sale: K-promoter


control cabinet promoter
safety promoter

Training: www.sitrain.com
Author (name, Email): Andrea Loesch, andrea.loesch@siemens.com

Siemens Aktiengesellschaft www.siemens.de/lowvoltage


Industry Sector, Industry Automation © Siemens AG 2006
Low Voltage Änderung vorbehalten
Postfach 48 48, D-90327 Nuremberg

You might also like