DTMA-1800-UMTS-12-AISG: Fullband Double Dual Duplex Tower Mounted Amplifi Er (Masthead Amplifi Er)
DTMA-1800-UMTS-12-AISG: Fullband Double Dual Duplex Tower Mounted Amplifi Er (Masthead Amplifi Er)
DTMA-1800-UMTS-12-AISG: Fullband Double Dual Duplex Tower Mounted Amplifi Er (Masthead Amplifi Er)
• Compact line
• Double units for easy use with XXPol antennas
• Supports AISG 1.1 and 2.0 (default)
• Suitable for antenna RET control according to AISG/3GPP standard Ant1
• Bypass mode to ensure cell operation in case of DC power down Ant2
734365 45 - 125 mm
Connectors RF 7-16 female (long neck), 8-pin female, IEC 60130-9, (Pin 3:
AISG RS485B, pin 5: RS485A, pin 6: 10 - 30 V DC, pin 7: DC return,
other pins: Not connected)
Mounting Wall mounting: With 4 screws (max. 8 mm diameter) /
Mast mounting: With additional clamp set
Weight 8.0 kg
Dimensions (w x h x d) 168 x 274 x 120 mm (without connectors, without
mounting brackets)
* see note on page 4
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
DTMA-1800-UMTS-12-AISG
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
Subject to alteration.
936.4514c
Dimensions
Subject to alteration.
936.4514c
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
DTMA-1800-UMTS-12-AISG
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
Mounting Instructions
Subject to alteration.
The coupling torque at 7-16 connectors is 25 - 30 Nm! The tightning torque for fixing the Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress
AISG connector must be 0.5 - 1.0 Nm (‘hand-tightened’). (e.g. strain caused by oscillating support structures), may result in the breakage of a mast
mounted device or even cause it to fall to the ground.
It is recommended to install the DTMA’s with the antenna connectors pointing upwards and
the BTS connectors pointing downwards. KATHREIN tower mounted amplifiers are designed to operate under the environmental
conditions as described in ETS 300 019-1-4 class 4.1E and have passed environmental
In case of DTMA’s with RET-connectors (Remote Electrical Tilt-connectors according to tests as specified in ETS 300 019-2-4. The homogenous design of KATHREIN‘s tower
AISG Standard) it is recommended to mount the DTMA’s in such a way that the RET- mounted amplifiers use identical modules and materials. Extensive
connector always points downwards! A downward slanted mounting position between the tests have been performed on typical samples and models.
vertical and horizontal plane is also allowed.
The installation team must be properly qualified and also be
AISG Setting familiar with the relevant national safety regulations.
The protocol of the software interface can be switched between AISG 2.0 / 3GPP and The details given on our data sheets have to be followed carefully
AISG 1.1 and vice versa with a vendor specific command (depending on default setting). when installing the antennas, filters, combiners, amplifiers and
If the primary station does not support the default setting, it has to be switched over before
936.4514c
accessories.
system start-up. Please contact Kathrein for further information.
The limits for the coupling torque of RF connectors,
Please note recommended by the connector manufacturers must be obeyed.
The DTMA is not designed for permanent operation under water. Test conditions for the Any previous datasheet issues have now become invalid.
IP67 rating: Submerge depth 1 m, submerge time 1 hour.
As a result of more stringent legal regulations and judgements regarding product liability,
we are obliged to point out certain risks that may arise when products are used under
extraordinary operating conditions.