Nothing Special   »   [go: up one dir, main page]

Intelligent Healthcare

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

Intelligent Healthcare

Communication Systems
w w w . z k r . c o m . t r
Intelligent Healthcare
Communication
Systems

Kıraç Group has been succeeding in the manufacturing sector since 1982. In 2005 Kıraç
Group stepped into low-voltage systems and information technology by establishing
Kıraç Bilgi İletişim Incorporation and responding to market demand, started producing
Intelligent Healthcare Communication Systems under the trademark ZKR in 2010.
With the aim of bringing the wider world of institutional electronics and software into
modernity at reasonable prices, we branched out into information management and
energy monitoring as well. We believe that the quicker the worlds’ institutions can adopt
the latest advances in technology, the better and more equal human quality of life can
be across the globe.

Today, we are the leader of the local market with more than 750 systems installed
worldwide and over 38 million patients served.
“Our systems adapt to
changing ward
environments.
We evolve with you.”

OUR VISION
Our aim is to move our leadership to the
world market and improve our technology
with flexibility and innovation, and exceed
the expectations of digital hospital
management system standards.

OUR MISSION
ZKR Intelligent Healthcare Communication
technology is among the best in the world.
It features many options such as voice over
IP communication (VoIP), data logging
with Mifare Cards, monitoring data f rom
HIS (Hospital Information System) and
integrating HIS with our MCW mobile
application. We focus on the software
integrations that give the most streamlined
solutions for hospitals and patients. Our
success is based on thinking about your
future needs.
Is your Healthcare ?
Communication System
Intelligent ?
Does your system allow you to...
• Know when your patients need help?
• Track which nurses respond to patient calls?
• Track how long it takes nurses to respond to a patient call?
• Track how long nurses spend in patient rooms?
• Use multiple call types and escalations so the critical cases always take
priority?
• Talk to your patients directly so you are informed of the details of the
incident immediately?
• Notify your technical staff of any faults and malfunctions in the system
4 automatically?
• Only notify selected teams for selected types of calls, reducing alarm
fatigue?
• Continue service and full functionality through local backup systems even
when server connection fails?
• Automatically forward calls from one Nurse Station to another for Night
Mode?
• Reconfigure which rooms are connected to which nurse stations without
touching a single cable?
• Prevent unauthorized people from initiating false alarms for important call
types such as Code Blue (Cardiac Arrest)?
• Update your system software remotely?
• Integrate with other hospital systems allowing a unified source of
information?
• Allow your patients full control of their environment such as lighting,
curtains, air conditioning, music, TV?

does.
Pure IP

ZKR Comfort and Versatile series are pure IP


systems with fully structured cabling, allowing
for detailed and easy device fault monitoring
with different notif ications for different types of
failures, such as power loss, disconnection, major Pure
malfunction, etc. The system can also update the IP
software of all of its component units through the
network automatically.

Middleware Integration

Integration Software is the process of combining


data f rom many different sources, typically for
analysis, business intelligence, reporting, or
loading into an application. Our systems take one
step further and work as Middleware – as a bridge
between different software.

• Patient Monitoring Integration

• HIS (Hospital Information System)

• Fire Alarm Integration


5
• PBX Integration

• Building Management System

• Infant Tracking

• Public Voice Address Integration

Web-Based Server Interface

We offer fully backed up server options with hot


swap capabilities based on hospital demand to
ensure continued service.

Our systems work f rom a single server with a user-


f riendly web-based Application and Reporting
Interface allowing you to monitor what types
of calls were made when and which personnel
responded to them, as well as the use of the MCW
One mobile application, detailing when personnel
received and read messages and calls, and when
they declined calls, etc.
Flexible Software -
Workflows and Eff iciency

Our systems are tailored to your requirements.


Our flexible software allows us to accommodate
user-designed workflows through intelligent call
routing. Calls and alarms need only go to the
relevant assigned staff, reducing general alarm
fatigue and promoting a healing environment—
helping you supply eff icient quality patient-care
and manage your most valuable resource: time.

Fully VoIP Structure

Voice calls can be made in the Versatile Plus and


Comfort systems, f rom room to room, nurse station
to room, nurse station to nurse station, patient
handset to nurse station, and f rom the MCW One
6 mobile application to any of the units connected to
the system.

At the institution’s request all voice calls made


on the system can be stored on the central ZKR
application server, and listened to at any time.

Modern Room Control

Our Room Control Units are touchscreen, with easy


to navigate menus and clear indicators regarding
the connection status and active call statuses.
These menus are conf igurable to the needs of
the hospital. Highly conf igurable room control
units allow new custom types of emergency calls,
consultation calls to any hospital branch specif ied
by you, different quantities of connected pull-cord
or wall button type call points, etc.
Scalable

The system is scalable and modular, and


unlimited in scope. Our Intelligent Healthcare
Communication Systems easily grow with your
hospital and respond to your needs without
needing to completely reinstall already installed
portions of the system.

Easy Maintenance

ZKR system comprises of easy maintenance


modules. Our systems can scale f rom 10 beds to
10,000 beds with no problems and expand with
your institution in the future.

All equipment within the system detect any


failures automatically within 30 seconds and
generate Failure Notif ications to the assigned
technical teams of the institution. In this way
accurate address error information is sent to the
right people quickly and reliably
7

Stability and Backup

The ZKR system architecture was designed to be


99.95% operational.

Thanks to fully structured cabling, one


malfunctioning unit or cable does not affect other
units.

In case of a Nurse Panel malfunction, calls will


automatically be forwarded to another Nurse Panel
def ined within the system, and the system will
continue normal functionality through the other
Nurse Panel uninterrupted.

All system logs are kept centrally in the local ZKR


application server, and automatically backed
up. These logs can be monitored through a web
based interface by any authorized personnel f rom
any computer on the network. The logs can be
exported to a spreadsheet or printed.
Product Family

ZKR Product Family


IP SYSTEMS

WIRELESS SYSTEMS

UNIVERSAL

PATIENT DEVICES ROOM DEVICES

The patient handset allows the patient’s


Room Control Units Call Unit Devices
condition to be reported quickly to the
hospital staff in an emergency situation.
These products vary according to the Comfort Bedside Call Unit
model of solution. With different handset Room Control Unit 10“ ZKRUNCIPWL10100
models, patients can make internal and ZKRUNCIPCNFRMC002 ZKRUNCWRWL10100
external phone calls, call for their needs,
and control the TV and lights.

Comfort VoIP Handset


ZKRUNCIPCNFHND001
Pull-cord Call Unit
ZKRUNCIPWC10100
ZKRUNCWRWC10100

Versatile Plus
Room Control Unit 5“
ZKRUNCIPRMCN130
ZKRUNCIPRMCN140

VoIP Pull-cord Call Unit


ZKRUNCIPCNFWCS001
Pro Handset
ZKRUNCIPHS10200 Versatile
Room Control Unit 4.3“
ZKRUNCIPRMCN100

Code Blue Unit


ZKRUNCIPCDBL101

Air Plus
Basic Handset
ZKRUNCIPHS10100 Room Control Unit
ZKRUNCWRHS10100 ZKRUNCWRRMCN100

Custodial Cell Call Unit


ZKRUNCIPWL10200
Product Family

GROWING DEMANDS OF MODERN HOSPITALS

The ZKR product family includes a wide range of products that have easy integration with
each other. Inter-compatible products enable us to offer more flexible solutions to meet our
customers’ requirements.

STAFF DEVICES CORRIDOR DEVICES CONTROL DEVICES

Staff devices are used to receive all Corridor devices are used to help Control devices control the operation
call types. All logs can be reported the operation of other devices, and of all systems and provides logs to
on staff devices in detail. they are easy to use. hospital.

VoIP Nurse Control Panel 10ʺ Air Basic Dot Matrix Panel Senset 3 Input Module
ZKRUNCIPNCNP10V ZKRUNCWRNCSPC10 ZKRUNCIPIZLMOD1

Over Door Light


VoIP Nurse Control Panel 7ʺ ZKRUNCORTKLMP10 Function Control Module
ZKRUNCIPNCNP7 ZKRUNCORTKLMP20 ZKRUNCIPRMLK100
ZKRUNCORWRLMP10

Text Panel ZKR Application Servers


ZKRUNCIPTXTPNL18

Central Monitoring Software Application Server M1000


ZKRUNCIPCNTMNT18 ZKRUNCIPSR10200

Application Server M500


ZKRUNCIPSRM0500
Pager
ZKRUNCIPPOSPG10 Application Server M150
ZKRUNCIPSRM0150

Application Server M50


ZKRUNCIPSR10400

Application Server M30


ZKRUNCIPSR10300

MCW One Versatile Application Server


ZKRUNMCWTER1100 ZKRUNCIPSR10100
Signal Repeater
ZKRUNCWRSITKR10 Air Application Server
ZKRUNCIPSR10102
Room Devices

Room Devices
Comfort Room Control Unit 10”

The Comfort Room Control Unit ensures communication between the Nurse Control Panel and
the call buttons in patient rooms. This unit is suitable for both flush and shallow montage.

This unit has a 10‘’ Touchscreen and a built-in Mifare card reader. It supports up to 8 call units
(bedside call units + pull-cord call units) by standard. On the Comfort VoIP Room Control Unit,
you can make voice calls and contact the hospital staff. Code Blue and other custom emergency
codes can be initiated through an onscreen menu. Consultation calls can be made to any branch
specif ied by the institution.

Patient information f rom HIS (Hospital Information System) can be monitored through server
based integration by touching the corresponding bed icons on screen. Information about the
patient can also be edited through the touchscreen if desired.

• PoE (Power Over Ethernet)


• Full Duplex
• SIP Protocol
• Conference Call
• Internal and External Call
(with tracking system for billing)
• Built-in RFID card Reader
• Timer/Stopwatch
• Menu option for personalized task lists based
10 on personnel ID cards
• Can display hospital advertisements or other
videos
• Can display training videos for specif ic
healthcare procedures

Versatile Plus
Room Control Unit 5”

This unit ensures communication between the


Nurse Control Panel and the call buttons in
patient rooms. The Room Control Unit is suitable
for both flush and shallow montage. It features a
5’’ touchscreen and a built-in Mifare card reader.
Optionally a basic task list can be accessible f rom
the onscreen menu.

This unit can def ine up to 8 call units. Its durable


structure and modern software ensure the best
operating time and performance.
Room Devices

Versatile Room Control Unit 4.3”

This unit ensures communication between


the Nurse Control Panel and the call buttons
in patient rooms. The Room Control Unit is
suitable for both flush and shallow montage.
It has a 4.3’’ touchscreen and supports up to
8 call units.

Air Plus Room Control Unit

You can have detailed information and log


reports on each interaction made with the
built-in Mifare Card Reader on the Room Control
Unit.

6 buttons are located on the control unit and are


programmed by default to serve the functions of an assist
button, code blue button, room clean button, etc. There
are also 2 special function keys that can be adjusted and
programmed according to the needs of the institution.

• 433 MHz Encrypted Communication Protocol


• Standard 110-240 Volt
• Built-in Mifare Card Reader
• Ambiance LEDs 11
• 2 Programmable function buttons

ID
p l i f i e d with RF
im
p r o c e s s e s a re s t cards to
verify
C a re m a r
use MIFA
R E s ho wish
ms onnel w
l pers
Our syste f hospita allows
rm is s io n s o
o u s c alls. This
the p e ate v a ri t types
it ia te o r termin e s e t fo r differen
to in b m,
p e rm issions to r, C o d e Blue Tea
custo m oc to s e r ve r
u s e rs ; nurse, d a ll o w s our call
of ca rd . It also
staff, etc spond to
cleaning u rs es that re es
data of th
e n hich nurs
to log ID o r ts d e tailing w y w e re in
ra p h ic al rep o w lo n g the
calls. G , h er-
ich calls n the us
ed to wh nitored o
respond an b e m o
m, etc . c rface.
each roo a s e d s er ver inte
web -b
f riendly
Room Devices

Bedside Call Unit

The Bedside Call Unit is used patient rooms. There are backlit call
and cancel buttons on the unit. In an emergency, a patient uses the
call button to make an emergency call which appears as an alert
on the Nurse Control Panel. Typical locations for this unit are on the
walls of patient rooms and living areas as needed.

Pull-cord Call Unit

The Pull-cord Call Unit is used in patient bathrooms or similar areas.


There is a backlit cancel button and an emergency call pull-cord
on the unit. In an emergency, a patient pulls the cord making an
emergency call. This appears as a WC Emergency Call on the Nurse
Control Panel. The system gives priority to WC Emergency calls and
they appear before other calls.

VoIP Pull-cord Call Unit

The VoIP Pull-cord Call Unit is used in patient bathrooms or similar


areas. There is an emergency call button and an emergency call
cord on the unit. In an emergency, the patient pulls the cord to
immediately start an emergency voice call with the assigned Nurse
Control Panel. When the emergency call button is pressed, a regular
priority WC Emergency Call is made.
12

Code Blue Unit

The Code Blue Unit is mounted on the wall as needed in the


hospital. There are backlit call and code blue buttons on the unit.
The call button may be pressed to initiate a nurse call which
appears as an alert on the Nurse Control Panel. The code blue
button may be pressed to start a Code Blue call. The same button
can be conf igured as an assist call button.

Custodial Cell Call Unit

The Custodial Cell Call Unit is flush mounted on the walls of prisoner
cells, psychiatric units or similar areas. There are nurse call and call
termination buttons on it. It has an aesthetic and durable structure.

• Suitable for flush montage to prevent disassembly


• RJ45 socket allows easy installation
• Stainless steel raw material
• Vandal-proof, IK-10 certif ied in structure for use in psychiatric
clinics and prisons
Patient Devices

Patient Devices
VoIP Comfort Handset

With voice communication, patients can speak directly to the


nurses assigned to them. This system allows hospital staff
to save time on service, prioritize critical cases, and comfort
patients through voice communication. Thanks to the ZKR
Comfort System, all conversations between hospital personnel
and patients can be recorded, giving opportunities for quality
control. Evaluation of nurse performance can be displayed as a
graph on the server interface.

The Comfort VoIP Handset is easy to use. Patients can press


the button labelled “Nurse Call” when they wish to send a
regular nurse call signal, or they can press the large call button
when they want to speak with the nurse assigned to them. The
product has a user-f riendly, ergonomic, and hygienic structure.
Using intelligent controls, patients can make internal and
external phone calls with automatic billing. ZKR Comfort Nurse
Call Systems can integrate as PBX analog, digital, and VoIP
with any SIP-based brands.

• PoE (Power Over Ethernet)


• PBX
• Full duplex
• SIP protocol
• Conference call
• Function control within the room through Building Manage- 13
ment System integration (such as lighting or window blinds)
• TV channel and volume control
• Internal and external call (with tracking system for billing)

Pro Handset

The Pro Handset is designed to inform the staff of the


patient’s condition immediately.
• Easy to use
• Works though connection to Bedside Call Unit
• TV channel and volume control
• EL lights allow visibility in the dark
• Function buttons help to control room lighting, reading
lamp, window blinds, etc.

Basic Handset

The Basic Handset allows the patient’s condition to be reported


quickly to the hospital staff in an emergency situation. The device
works through connection to the Bedside Call Unit. Easy-to-
understand images indicate the functions of the buttons.

Thanks to LEDs on the unit, the product is easily noticeable in the


dark. These LEDs vary according to the last call made.
Staff Devices

Staff Devices
VoIP Nurse Control Panels
Nurse Control Panel 10ʺ

The statuses of all working Room Control Units


connected to the panel can be monitored actively.
All errors and notif ications shall be displayed on the
information panel. Emergency codes, WC calls, and
normal calls may be monitored.

All processes passing through the system are logged. All


logs can be reported in detail. There are a conf igurable
number of room monitoring icons on the interface. Call
statuses are tracked in real time via these icons.

Nurse Control Panel 7ʺ


MCW One

Research shows that healthcare professionals spend


nearly 35% of their time trying to reach information.
The MCW One Handset ensures you get the right
information at the right time.

This mobile device allows you to receive all or f iltered


calls f rom the Nurse Call System, accept or decline
the calls or forward them to other team members,
14 talk directly to patients on their Comfort system VoIP
handsets, talk through Room Control Units, assign tasks
for team members and monitor the completion of these
tasks, receive integrated hospital device alarms, check
Laboratory results f rom Hospital Information System,
and remember prof iles for different staff members
through NFC card authorization.

The application can be licensed for use on Android


based smartphones, but some of the features such as
card reading might not be possible depending on the
smartphone’s features.

Central Monitoring Software

The ZKR Central Monitoring Software is a web-based


monitor that observes all activities such as nurse calls,
code blue (and any custom emergency codes), assist
calls, and nurse presences throughout the hospital. It
can show picture IDs of personnel that are present in
patient rooms.

Different parameters (call type, department, and floor


info) can be f iltered based on needs. In this way, the
focus of health personnel can be directed and reaction
and intervention times can be minimized.
Corridor Devices

Corridor Devices
Air Basic Dot Matrix Panel

• Displays 4 calls in order of priority (others wait in queue)


• Adjustable 5 digits can show floor, room, bed number, etc.
• Color LEDs indicate call type
• Supports up to 64 beds
• Audible alerts according to call type

Over Door Light

The Over Door Light is located above the patient room


door in the corridor. Its half-sphere shape makes it easily
noticeable f rom any angle of view. If there is an emergency
in the room, it can be seen clearly f rom the corridor. It can
warn with three main colors, red, green, and blue, and
combinations of these (cyan, yellow, magenta, and white),
depending on the call status of the room.

It has very low energy consumption and uses environment-


f riendly LEDs. It is flush mounted above patient doors by
standard, but a surface montage box can be provided if
necessary.

Text Panel 15

The Text Panel is a scrolling 15-character dot matrix screen.


It works as TCP-IP on the network, displays the calls as text,
and gives audio alerts. Based on preference it can be set to
display only specif ic types of calls or all calls. It works with
220V.

ZKR Pager

• 8-line LCD screen


• Message handling in POCSAG standards
• Uses a rechargeable battery
• 99 message memory
(oldest record overwritten when full)
• Passive Tag allows the pager to be used instead of a Mifare
personnel card within the system

Signal Repeater

The Signal Repeater may be used in wireless systems to


expand the coverage area if the distance between the call
units and the Dot Matrix Nurse Panel is excessive. There is
no limitation on the number of Signal Repeaters that can be
used in the environment. Uses 5V.
Control Devices

Control Devices
Function Control Module

Provides control of On/Off for two different functions


within the room (such as reading lamp or window
blinds) f rom the patient handset. One Function
Control Module must be installed per one Patient
Handset, connected between the Room Control Unit
and the Bedside Call Unit via its two RJ45 ports (in/
out).

• Two dry-contact relay ports


Senset 3 Input Module

Provides interface with various external equipment


such as ECG Patient Monitors, or Saline Solution bags
to track the quantity of remaining Saline Solution.
This module allows the Nurse Call System to generate
notif ications and alarms automatically through data
received f rom the existing medical equipment and
devices. This way healthcare personnel are notif ied
immediately even when the patient is unable to make
a call manually.

16

ZKR Application Server

The server controls the operation of the Comfort, Versatile Plus, Versatile, and Air Plus (optional)
systems used in hospitals. The server provides log reporting through a web interface and enables
integration with other systems used throughout the building. Our servers have a Linux-based
robust and reliable inf rastructure.

• Linux Operating System


• Fully redundant structure
• Troubleshooting and error
notif ication of all modules connected
to the system
• Voice Record Module (for Comfort
and Versatile Plus systems)
• Integration with WiFi mobile phones
• Integration with DECT telephones
• Integration with pagers
• Integration with PBX and ability to start emergency codes
(such as 1111, 2222, 3333)
• IP, PRI, BRI, Analog Connection
• Integration with Fire Alarm Systems (Modbus, Bacnet, Special TCP connection types)
• Integration with CCTV Systems (Serial Port, Special TCP connection types)
• Integration with RFID Systems (Web service, Special TCP connection types)
• Integration with Hospital Information System
• Integration with Lighting Automation
Logs and Reporting

Logs and Reporting


Our web-based server interface allows your hospital
to access the server settings and event logs f rom
anywhere on the hospital network. Simply open a web-
browser on any computer on the same network as the
server, and type in the server’s IP address. After logging
in, technical personnel can def ine rooms and teams on
the server without interrupting the functionality of the
nurse call system.

Here hospital administrators can also view f ilterable


call logs, with all relevant data, including call type,
timestamps, and elapsed time for both nurse response
and nurse presence. Thanks to our RFID card-based
system, administrators can see which nurses respond
to the most calls, and how they are spending their time.
All of this data can be viewed as easy-to-read graphical
reports, so that the hospital can use real data to decide
how better to manage their resources.

If the system ever needs an update in software, or a change in conf iguration with help f rom
headquarters, we can connect to a hospital technician through the internet and access the
server directly to provide the hospital with support. There is no travel time or travel expenses, we
are by your side, wherever you need us.

17

Number of Calls per Call Type MCW Usage Logs

Statistics of Answered Calls Call Event Logs


Integration Software

Integration Software
We are very flexible with software integration with different systems used throughout the
hospital. The following are some examples of integrations we support, but anything
is possible—we work together with you to f ind the best solutions to improve the quality of service
and save time and future costs for the hospital.

Middleware Functionality
The ZKR system can function as middleware for multiple different systems
and allow all integrated systems to intercommunicate to achieve their full
potential in functionality. All integrated systems can be monitored f rom a
single operation center screen.

Patient Monitoring Integration

Integration with patient Monitoring Devices such as Saline Solution


Controller, allowing nurses to be automatically notif ied when the saline
solution is running low or Pressure Pads which allow conf igurable
automatic alarms to be sent to nurses when a patient leaves his bed, or
when he has fallen out of bed. It can also trigger automatic emergency calls
when medical devices such as ECG/EKG monitors give alarm.
Supported protocols : TCP/IP (Server, Client), IP HL7, Rest Web Services

18 Nurse Station

Central
Monitoring
Unit
MCW Alert

WiFi Network

Switch MCW

ZKR WiFi Coverage


Application MCW
Backbone Server
Switch

MCW

ECG / EKG
Integration Software

Hospital Information System

Integration with the Hospital Information System allows the demographic


data, lab results, and EMG unit alarms relevant to call initiating patients to be
displayed on the Room Control Unit screens, Nurse Control Panels, or even
MCW One enabled smartphones.

This integration also allows nurses to view information such as allergy notes
about the patient simply by pressing his bed icon on the Room Control Unit.
Interactive hospital meal menus f rom HIS can be placed in the Room Control
Units allowing the patient or their attendant/companion to easily order
meals for the patient directly f rom the Room Control Unit touchscreen.
Supported protocols : IP HL7, Rest Web Services

Nurse Station

Central
Monitoring
Unit
19

Switch WiFi Network


MCW

ZKR
HIS Client
Application
Backbone
Server
Switch

HIS Client

HIS Server

Switch HIS Client


Integration Software

Fire Alarm Integration

Integration with Fire Detection Systems allows the system to show the origin
of the alarms on the nurse control panels of relevant zones and send this
information to the communication devices (MCW One enabled smart phones,
pagers, DECT phones, and WiFi phones) of the personnel that need to know.
The system can also automatically trigger conference calls for Fire Safety
teams on MCW One allowing clear communication for faster safer response
plans.
Supported protocols : Rest Web Services, Modbus IP

!
!
MCW

Nurse Station

Central
!
MCW MCW
Monitoring
Unit

Automatic
Conference
Call
20 Switch WiFi Network
MCW

ZKR
Application
Backbone Server
Switch
Detectors Detectors

Manual Manual
Fire Alarm Fire Alarm
Fire Trigger Trigger
Alarm
System
FIRE!

PBX Integration

Integration with the hospital telephone switchboard to allow for Internal and
External calls f rom patient handsets with automatic billing, and initiation of
various custom emergency codes f rom any telephone in the hospital (eg. 2222
for code pink: child abduction, etc.)
Supported protocols: SIP, Analog FXS
Integration Software

Building Management System Integration

Integration with Building Management Systems such as lighting automation


allow the Intelligent Healthcare Communication System to automatically turn
on the lights of corridors where a nurse call is triggered, helping nurses reach
where they are needed.

When combined with HIS (Hospital Information System) integration, we can


automatically cut power to empty rooms in the hospital and turn on the power
to these rooms when a patient is booked to them in the HIS, saving power and
money for the hospital.
Supported protocols : Rest Web Services, Modbus IP

Light Controlling

Device Fault Monitoring

Energy Control

21

Infant Tracking Integration

Integration with Infant Tracking Systems allow an alarm to be sent to relevant


nurse control panels and communication devices of relevant personnel when
a baby is taken out of “safe zones”. This can be combined with Access Control
System integration if available to lock down specif ied areas of the hospital
automatically when the infant alarm is triggered.
Supported protocols: Rest Web Services, Modbus IP

Public Voice Address System Integration

Integration with general and emergency voice alarm systems allows you to
make SIP-based announcements to selected zones through VoIP-enabled
Nurse Control Panels. With this integration the hospital doesn’t need separate
expensive microphones for these announcements, because they can be made
through the built-in handset of the Nurse Control Panel.
Supported protocols: SIP
Workflow

MCW One

The patient makes a nurse call f rom his handset, but the nurse
assigned to him is busy. The patient’s call is automatically forwarded
to another nurse who accepts the call on her MCW One handset.
The nurse speaks to the patient, calming and reassuring him as she
goes to his aid.

The patient makes a nurse call f rom a


Pull-cord Call Unit. The nurse receives the
call. After she provides care for the patient,
the nurse shows her card to the Room
Control Unit as she leaves the room.
Mifare Card Pull-cord
Call Unit

22

Comfort
MCW One
VoIP Handset

The patient makes a nurse call f rom his handset.


MCW One The nurse receives the call and realizes she will
need an assisting nurse. She calls for assistance
f rom MCW One. The other nurse comes to
help, and after they provide care for the patient
together they can show a Mifare to the Room
Mifare Card Control Unit as they leave the room.

Room Control
Unit
The patient’s vitals
on the monitor show
a critical situation. Mifare Card
Senset The senset module
picks this up and
Module
immediately triggers
a call to MCW One.
The nurse receives
Pull-cord the call and comes
to the patient’s aid Senset
Call Unit MCW One
immediately. Module
Workflow

The patient makes an external


Workflow
call to his family through his
Comfort VoIP handset.

Room Control Unit

The patient is distressed


and makes a nurse call
f rom his handset. The nurse
arrives to give him care but
his condition worsens. The
nurse makes a Code Blue
Handset call f rom the Room Control
Unit.

Medical
Aid
Handset

The Code Blue Team arrive to


tend to the patient. The Code
Handset Blue call will be cancelled upon
a Code Blue Team member
showing his card to the Room
Control Unit.

Mifare Card
23

Handset

Handset

The patient uses his Comfort handset to talk


to the nurse and make a request for tea.
The nurse uses MCW One to set a task for the
person in charge of handling this request. The
task completion is marked on MCW One.

ECG
Monitor

MCW One
Diagrams

Versatile Plus System Block Diagram

to ZKR UTP Cat6H


Application
Server
Nurse Control Panel Handset & Bedside Unit
3x2.5 mm2 NHXMH CABLE
CAT 6-HF CABLE
CAT 6-HF CABLE

Room Control Unit Over Door Light


Floor Network 3x2.5 mm2 NHXMH CABLE
Switch CAT 6-HF CABLE
CAT 6-HF CABLE

UTP Cat6H

Pull-Cord Call Unit

CAT 6-HF CABLE

Function Control Module


220V or
CAT 6-HF CABLE
PoE

Nurse Control Panel

Room 1 (2 Patients)

Patient Handset Patient Handset Pull-Cord Over Door


Bedside Unit Bedside Unit Call Unit Light

24
Versatile Plus
Room Control Unit
UTP Cat6H
Function
Control Module UTP Cat6H
Function
Control Module UTP Cat6H UTP Cat6H

220V or PoE

Room 2 (1 Patient)

Patient Handset Pull-Cord Over Door


Bedside Unit Call Unit Light

Versatile Plus
Room Control Unit

Function UTP Cat6H


Control Module UTP Cat6H
UTP Cat6H

220V or PoE
Diagrams

Comfort System Block Diagram

to ZKR UTP Cat6H


Application
Server Nurse Control Panel
Comfort Handset
3x2.5 mm2 NHXMH CABLE
CAT 6-HF CABLE CAT 6-HF CABLE

Comfort
Over Door Light
Floor Network Room Control Unit
Switch 3x2.5 mm2 NHXMH CABLE CAT 6-HF CABLE
CAT 6-HF CABLE
UTP Cat6H

Pull-Cord Call Unit

CAT 6-HF CABLE

Function Control Module


220V or
CAT 6-HF CABLE
PoE

Nurse Control Panel

Room 1 (2 Patients)
UTP Cat6H PoE
Pull-Cord Over Door
UTP Cat6H PoE Call Unit Light

Function
Comfort Room Control Unit
Control
UTP Cat6H Module

25
Comfort Handsets

UTP Cat6H
220V UTP Cat6H
or PoE

Room 2 (1 Patient)
Pull-Cord Over Door
UTP Cat6H PoE
Call Unit Light

Function
Comfort Room Control Unit Control
UTP Cat6H
Module

Comfort Handset

UTP Cat6H
220V UTP Cat6H
or PoE
Diagrams

Air Plus System Block Diagram

to ZKR UTP Cat6H


Application
Server Nurse Control Panel

3x2.5 mm2 NHXMH CABLE


Handset & Bedside Unit
CAT 6-HF CABLE

Floor Network
UTP Cat6H

Room Control Unit Over Door Light


Switch

ZKR Modem Pull-Cord Call Unit

Modem
220V AC 220V AC

Nurse Control Panel

Room 1 (2 Patients)

Patient Handset Pull-Cord Over Door


Bed Side Units Call Unit Light

26

Air Plus
Room Control Unit
220V AC

220V AC

Room 2 (1 Patient)

Patient Handset Pull-Cord Over Door


Bed Side Unit Call Unit Light

Air Plus
Room Control Unit

220V AC
220V AC
Diagrams

Air Basic System Block Diagram

Air Basic Nurse Panel


(Dot Matrix Panel)

Air Basic Nurse Panel Handset & Bedside Unit

ZKR Signal Repeater Over Door Light

Pull-Cord Call Unit


RS232 Cable

220V AC

RS232 Socket

220V AC

Signal Repeater
(as many as required
Reporter Software to extend coverage)

Room (2 Patients)

Patient Handset Pull-Cord Over Door


Bed Side Units Call Unit Light

220V AC
Over 750 systems installed worldwide.
Over 38 million patient served.

Bilkent Integrated Health Campus


3660 Bed Capacity
Partnership with Siemens - Fully Integrated System

Adana Integrated Health Campus Eskişehir Integrated Health Campus


1550 Bed Capacity 1080 Bed Capacity

CONTACT US

Ümit Mah. Okullar Sk. No:16 info@zkr.com.tr


06810 Çankaya / Ankara - TURKEY export@zkr.com.tr

+90 (312) 446 03 44 +90 (312) 446 03 34

w w w . z k r . c o m . t r

You might also like