Nothing Special   »   [go: up one dir, main page]

GNT 190

Download as pdf
Download as pdf
You are on page 1of 4
SERIES INTER Diesel Generator wa 50 H2 wa 60 Hz GENPOWER GENERATOR Output Ratings 3 Phases, GF 0.8 Voltage, Frequency Prime Standby GNT 190-400 Volt, SOHz 173 KVA/138KW 190 KVA/ 152 KW QNT 220-480 Vol, 60 Hz 200 RVA/ 160 KN 220 KVA/ 176 KW ‘Standard Reference Conditions: Note: Standard reference conditions 25°C Ai Inlet Temp, 100 m, 60% relative humidity Genpower Generator Set Standards TSISO 8528, 0 8528, BSSO00, ISO 3086, IEC 60034, NEMA MG-1.22, Note: The alternator output voltage matching the desired type of connection with the terminals using the following voltages can be 50 Has 200/115V - 20/1 10V - 220/127V - 230/115V - 380/220V - 400/230V 415/240v 60 Hz 208/120V - 220/127V - 240/139V - 380/220V - 440/258V - 480/277V Prime Rating: Where there is no mains power, a form of continuous operation under variable load generator. The average oad is variable prime power 80% of should not. 10% overload available for 1 hour in 12-hour period is allowed. ‘Standby Power: Mains power, backup power supply, the device is a form of working under load. Maximum overload of powers nat allowed, Annual operating time is limited to a maximum of 500 hours. Canopy «Easy iting and moving * Metal parts are coated with electrostatic polyester coated, powder painted + 25-30 dbA series, Heat-insulated exhaust system * Acoustic insulation with rot* proof, moisture-repellent and non-flammable material (per DIN 4102 A2) += Double swinging doors for ease of service Ratings & Performance Data GNT190 — GNT 220 Engine Make & Model: INTER / 1DE6150TG ‘Ntermator Make & Mode Stamford /UCI274F Genpower / GNP 270M2 W12/4 Control Panel Make & Model ComAp / AMF25 Base Frame Heawy Duty Fabricated Steel Engine Speed pm 1500 1800 Frequency He 50 60 Fuel Tank Capacity lt 256 %50 22,0 8 FuelConsumption %75 lth 290 356 %100 40,0 46,2 General Features * Tropical type radiator, fan, belt and enclosures, * Vibration dampers. ‘Open type gensets industrial type exhaust silencer ‘AMF contol panel + Buil-in type fuel tank chassis. ‘* Mechanical fuel level indicator + Battery pack and cable set. «The original engine ll, fuel, dry type air iter. Options * Contact your supplier for non-standard requests + The generator output breaker (MCB) + Eternal type transfer switch (ATS) + Dual operating systems + Low water level switch + Fuel tank heating and insulation systems * Single-and double-ale trailer + Synchronous systems «Private quiet cabins (cabins SSC) ‘Private hospital type and juicy exhaust systems ‘Mobile vehicle applications ‘ Atep or PMG alternator application No. of Cylinders 6 ‘Mignment Inbine Cycle 4 Stoke Induction Turbocharged MC Bore / Stroke mm 112/135 Compression Ratio nat Displacement lt 100 Cooling Method Water Governing Type Electronic Governing Class 1s0 8528-62 Moment of Inertia kgm (bite) 3,093.3) Electrical System Voltage/Ground 24 V/ Negative Charger Amps Amps. 55 Engine Speed rpm 1500 1800 Gross Engine Power KW (Hp) Prime 177 (241) 212 (288) Standby 195 (265) 233 (317) BMEP KPA (Psi) Prime 18 17 Standby 20 19 Ai Filter Type Replaceable Element Combustion AirFlow m/min (fm) Prime 110 140 Standby 120 150 Yana Hava Gig Basin Paine) 5 i Filter Type Spin-On, Full Flow Total OilCapacity Lt 150 il Pan lt 135 Oil Type APLCHA 15-40 il Cooler / Oil Cooling Method Ok/ Water Make and Mode! Stamford / UCIZ74F1 Cont. Power 400V-160KVA 480-206 kVA Efficiency % 923 92,7 AVR Model AS. 440 No. of Bearings Single Bearing Insulation Class, H Winding Pitch Code 28 Wires 2 Ingress Protection Rating [P23 Excitation System Self - Excited Voltage regulation 2%) Standards: 35 EN 60034, 885000, VE 0580, NEMA MGL-32,EC36, CSA 0222-100, AS1258 Fuel Filter Type Replaceable Element Recommended Fuel Class A2 Diesel Fuel Consumption Luh Prime «(110%~—100%_~—= 75% 50% GNT190 50Hz = 440-400 29.0220 GNI 220 60Hz 508 46.2 35648 Standby 100% 75% 50% GNT 190. 50Hz 440 31,9 24,2 GNI 220 60Hz 508 391272 Ne Boston desea spectro of 85 and conforming te BS285, Class A Cooling System Capacity Lt a Water Pump Type Centrifugal Heat Rejected to Water & Lube Oil kW (BTU/min) Prime 94 (5334) 106 (6000) Standby 103 (5864) 116 (6591) Heat Radiation to Room kW (BTU/min) Prime 24 (1364) 29,5 (1677) Standby 35,5 (2019) 45,5 (2587) RadiatorFan Load KW (Hp) 4,4 (6) 74 (00) Radiator Cooling Airlow m/min, 33 43 External Restriction to Cooling Airflow KPa 125 Nat: Designed to operate in ambient condos upto 50°C Silencer Type Industrial Pressure Drop Across Silencer Sys. 1,8, 25 Silencer Noise Reduction Lvl. db/A 16 u Maximum Allowable Back Pressure 50 70 Exhaust Gas Flow m/min (Cfm) Prime 31,9 (1128) 38,3 (1353) Standby 35,1 (1240) 41,8 (1476) Exhaust Gas Temp. °c Prime 528 495, Standby 542 515 Make and Model Genpower/ GNP 270M2 W124 Cont. Power 400V-173 WA 480V-206 KVA Efficiency % 92.3 927 AVR Model SK 460 Overspeed 2250 Short Circuit 5 Total Harmonic Content No Load <% 1,5 Wave Form NEMA 50% RF Radio Interference Woe 875 Cooling Air m'/se. 0514 0617 Radiant Heat KW (BTU min) 10,1 (574) 11,5 (653) Reaktans Xd 202 216 Xd 017 018 x"d 012 12 Motor Starting Capability KVA* 350 520 Based an 30% wage dpa 0 paver acta. Automatic Type Control Panel, Standard Equipment Manual Type Contral Panel, Standard Equipment * ComAp AMF 25 control panel « Battery charger I2W/5A « Isic tup stirmek igin 9 A Kontaktor * 9A contactor to drive the heater tube © Control relay « system protection insurance * Emergency stop button © 2 pieces suitable forthe power generator contactor (ATS), optional * The load output terminal (canopy types) © Configurable analog inputs * Selectable protections alarm / shutdown * Battery voltage, engine speed (pick-up) measurement * Configurable programmable binary inputs and outputs Warm-up and cooling functions * Generator and Mains control with feedback and return timer * Modem communication support « Sealed toIP65 The control panel via the LCD display the following measures are followed. + Engine Monitoring Oil pressure gauge ~ Cooling water temperature indicator (Temperature gauge) Fuel level indicator (Electronic float if applicable) Battery voltage indicator -11939 engine parameters (EC, electronic motors) * Statsties Working Hours ~ The number-starter ~ Emergency stop number ~Maintenance time ~Event records retention = ComAp AMF 25 control panel * Contral relay « System protection insurance * Emergency stop button * Suitable forthe power generator output breaker (TMS), optional «The load output terminal (canopy types) © Support of engines equipped with ECU (11939 interface) Comprehensive diagnostic messages; SPN/FMI codes; KWP2000 support ‘Automatic or manual start/stop ofthe genset Push buttons for simple control, lamp test Graphic back-lt LCD display 12864 pixels 6 LED indicators Parameters adjustable via keyboard or PC Mains measurements 50/60 Hz, V (3 phase) Generator measurements 50/60 Hz, V, A (3 phase), KW, kA, Kh * 3 phase Generator protections - Over / under voltage ~ Over / under frequency - Current/voltage asymmetry - Overcurrentéverload #3 phase AMF function - Over / under frequency - Over / under voltage - Voltage asymmetry © Alternator monitoring - 3 phase Voltmeter (3 phase + neutral) - 3 Phase ammeter + Frequency - kW meter, KVAr meter ~ kWh and kVAth energy meter © ‘Network monitoring 3 phase Voltmeter (3 phase + neutral) ~ Frequency kW meter kVAr meter A845 mm B: 700 mm C695 mm D: 3800 mm E:1570 mm F:1150 mm G: 2456 mm H: 4450. mm K: 644. mm. L644 mm OpenType Canopy Type Recommended concrete foundation base Width x Length x Height (mm) 1000240032000. 1150x3800x2250 ‘Width x Length: 22003800 mm Dry Weight (ke) 1598 210 Concrete: © Class B, A, 300 doses of concrete Iron: 1 row 08-12 mm thin ribbed mesh, gtd iron. jy '80,9001:2008 ‘OHSAS 18004-2007 Iso 14001:2004, wow.genpower.com.r

You might also like