Nothing Special   »   [go: up one dir, main page]

Amberjet 1200 Na L

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Lenntech

info@lenntech.com
www.lenntech.com
AMBERJET™ 1200 Na Industrial Grade Strong Acid Cation Exchanger Tel. +31-15-261.09.00
Fax. +31-15-261.62.89
Description

AMBERJET 1200 Na resin is a uniform particle size, high quality, strong acid cation exchanger designed for use in
all water treatment applications: softening as well as demineralisation. The uniformity and mean particle size of
AMBERJET 1200 Na resin have been optimised for use in industrial equipment. In H+ cycle, it can be used in mixed
bed applications paired with AMBERJET 4200 Cl resin. AMBERJET 1200 Na resin can be directly substituted for
conventional gel cation exchange resin in new equipment and in rebeds of existing installations.

Typical Properties
These properties are typical but do not constitute specifications.

Physical form Amber spherical beads


Matrix Styrene divinylbenzene copolymer
Functional group Sulfonate
Ionic form as shipped Na+
Total exchange capacity [1] ≥ 2.00 eq/L (Na+ form)
Moisture holding capacity [1] 43 to 47% (Na+ form)
Shipping weight 850 g/L
Specific gravity 1.26 to 1.30 (Na+ form)
Particle size
Uniformity coefficient [1] ≤ 1.2
Harmonic mean size 620 ± 50 µm
[1]
Fines content < 0.300 mm : 0.1% max
Maximum reversible swelling Na+ H+ : 10%
[1]
Contractual value
Test methods are available on request

Suggested Operating Conditions


Maximum operating temperature 135°C
Minimum bed depth 800 mm
Service flow rate 5 to 50 BV*/h
Maximum service velocity 60 m/h
Regeneration
Regenerant NaCl HCl H2SO4

Level (g/L) 50 to 240 40 to 150 40 to 200


Concentration (%) 10 4 to 10 1 to 8
Minimum contact time 20 minutes
Slow rinse 2 BV at regeneration flow rate
Fast rinse 1 to 3 BV at service flow rate
* 1 BV (Bed Volume) = 1 m3 solution per m3 resin

Performance

Operating capacity and ionic leakage depend on several factors such as water analysis, temperature and
regenerant level. The engineering data sheets EDS 0355 A, 0356 A, 0359 A, 0360 A, 0366 A and 0367 A provide
information to calculate them.
Limits of Use

AMBERJET 1200 Na resin is suitable for industrial uses. For all other specific applications such as pharmaceutical,
food processing or potable water applications, it is recommended that all potential users seek advice from Rohm
and Haas in order to determine the best resin choice and optimum operating conditions.

Hydraulic Characteristics

Figure 1 shows the bed expansion of AMBERJET 1200 Na resin as a function of backwash flow rate and water
temperature. Figure 2 shows the pressure drop data for AMBERJET 1200 Na resin as a function of service flow rate
and water temperature. Pressure drop data are valid at the start of the service run with a clear water and a
correctly classified bed.

/HQQWHFKEY
5RWWHUGDPVHZHJP
++'HOIW
info@lenntech.com
www.lenntech.com
Tel. +31-15-261.09.00
Fax. +31-15-261.62.89

All our products are produced in ISO 9001 certified manufacturing facilities.

AMBERJET is a trademark of Rohm and Haas Company and its affiliates, Philadelphia, U.S.A.
Ion exchange resins and polymeric adsorbents, as produced, contain by-products resulting from the manufacturing process. The user must determine the extent to which
organic by-products must be removed for any particular use and establish techniques to assure that the appropriate level of purity is achieved for that use. The user must
ensure compliance with all prudent safety standards and regulatory requirements governing the application. Except where specifically otherwise stated, Rohm and Haas
Company does not recommend its ion exchange resins or polymeric adsorbents, as supplied, as being suitable or appropriately pure for any particular use. Consult your Rohm
and Haas technical representative for further information. Acidic and basic regenerant solutions are corrosive and should be handled in a manner that will prevent eye and skin
contact. Nitric acid and other strong oxidising agents can cause explosive type reactions when mixed with Ion Exchange resins. Proper design of process equipment to prevent
rapid buildup of pressure is necessary if use of an oxidising agent such as nitric acid is contemplated. Before using strong oxidising agents in contact with Ion Exchange Resins,
consult sources knowledgeable in the handling of these materials.

Rohm and Haas Company makes no warranties either expressed or implied as to the accuracy or appropriateness of these data and expressly excludes any liability upon Rohm and
Haas arising out of its use. We recommend that the prospective users determine for themselves the suitability of Rohm and Haas materials and suggestions for any use prior to their
adoption. Suggestions for uses of our products of the inclusion of descriptive material from patents and the citation of specific patents in this publication should not be understood as
recommending the use of our products in violation of any patent or as permission or license to use any patents of the Rohm and Haas Company and its affiliates. Material Safety Data
Sheets outlining the hazards and handling methods for our products are available on request.