ZXA10 C300M (V3.1) SHDSL Service Commissioning Configuration Guide
ZXA10 C300M (V3.1) SHDSL Service Commissioning Configuration Guide
ZXA10 C300M (V3.1) SHDSL Service Commissioning Configuration Guide
1)SHDSL
Service Commissioning
Configuration Guide
ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲
LEGAL INFORMATION
By accepting this certain document of ZTE CORPORATION you agree to the following terms. If you do
not agree to the following terms, please notice that you are not allowed to use this document.
Copyright © 2014 ZTE CORPORATION. Any rights not expressly granted herein are reserved. This
document contains proprietary information of ZTE CORPORATION. Any reproduction, transfer,
distribution, use or disclosure of this document or any portion of this document, in any form by any
means, without the prior written consent of ZTE CORPORATION is prohibited.
and are registered trademarks of ZTE CORPORATION. ZTE’s company name, logo
and product names referenced herein are either trademarks or registered trademarks of ZTE
CORPORATION. Other product and company names mentioned herein may be trademarks or trade
names of their respective owners. Without the prior written consent of ZTE CORPORATION or the
third party owner thereof, anyone’s access to this document should not be construed as granting, by
implication, estopped or otherwise, any license or right to use any marks appearing in the document.
The design of this product complies with requirements of environmental protection and personal
security. This product shall be stored, used or discarded in accordance with product manual, relevant
contract or laws and regulations in relevant country (countries).
This document is provided “as is” and “as available”. Information contained in this document is subject
to continuous update without further notice due to improvement and update of ZTE CORPORATION’s
products and technologies.
ZTE CORPORATION
Address: NO. 55
Hi-tech Road South
ShenZhen
P.R.China
518057
Website: http://dms.zte.com.cn(TSM-Technical Support)
Email: TSM.Aftersales@zte.com.cn
Revision History
Author
Prepared
Date Document Version Reviewed by Approved by
by
2013-06 R1.0 Yan Xiaohui Wang Jun
Proposal: Before reading this document, you had better have the following knowledge and skills.
SEQ Knowledge and skills Reference material
ZXA10 C300M(V3.1) Multi-Service Access
1 Equipment commissioning
Equipment Configuration Manual
Follow-up document: After reading this document, you may need the following information
SEQ Reference material Information
ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. III
ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲
Summary
Chapter Description
1 Overview
2 Overall Description of Procedure
3 Description of Each Step
TABLE OF CONTENTS
1 Overview ......................................................................................................... 1
1.1 Usage Scale ..................................................................................................... 1
1.2 Objective .......................................................................................................... 1
1.3 Usage Method .................................................................................................. 1
FIGURES
TABLES
1 Overview
1.2 Objective
This SOP is applicable to the debugging personnel engaged in fixed network ZXA10
C300M products.
1. SOP explains what needs to be done in which sequence in order to achieve a goal.
2. Operation guide explains how to perform the operation procedure, that is, how to do
in detail.
Creating VLAN
Error
Checking configuration
Correct
Saving configuration
Ending configuration
2. Port configuration planning: port information of relevant rate and the VLAN where
the port is on should be opened.
3. Port PVC planning: plan the PVC data interconnecting with MODEM.
Network Diagram
SHDSL service access network diagram is shown in Error! Reference source not
found..
INTERNET
BRAS
Ethernet Switch
1/21/1
C300M
1/6/1 1/6/32
MODEM MODEM
PC PC
Data Specification
Personnel
Procedure
In config mode, use the command vlan x to create VLAN of SHDSL service.
ZXAN(config)#vlan 200
ZXAN(config-vlan)#exit
ZXAN(config)#vlan database
ZXAN(vlan)#vlan 200-231
ZXAN(vlan)#
Personnel
Procedure
Enter uplink interface mode and add it to the SHDSL service VLAN.
ZXAN(config)#interface gei_1/21/1
ZXAN(config-if)#switchport mode hybrid
ZXAN(config-if)#switchport vlan 200 tag
ZXAN(config-if)#exit
ZXAN(config)#
Configure VLAN in batch:
ZXAN(config)#interface gei_1/21/1
ZXAN(config-if)#switchport mode hybrid
ZXAN(config-if)#switchport vlan 200-231 tag
ZXAN(config-if)#exit
The uplink port mode should be consistent with the upper equipment port, if the upper
equipment port is tag mode, the uplink mode should be tag; if the upper equipment port is
untag mode, the uplink port mode should be untag.
Personnel
Procedure
Personnel
Procedure
Personnel
Procedure
[5]-gsfourWireBitInterleave
[6]-fourWireByteInterleaveEnhanced
[7]-fourWireBitInterleaveEnhanced
SpanConfWireInterface:[1]
SpanConfMinLineRate(192..30000kbps):[200]1000 //minimum line transmission rate
SpanConfMaxLineRate(200..30000kbps):[1552]3000 // maximum line transmission rate
SpanConfPSD(1-symmetric,2-asymmetric):[1]
SpanConfTransmissionMode(0-default,1-custom):[0]
SpanConfRemoteEnabled(1-enable,2-disable)):[1]
SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]
SpanConfCurrCondTargetMarginDown(0..10dB):[5]
SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]
SpanConfCurrCondTargetMarginUp(0..10dB):[5]
SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]
SpanConfUsedTargetMargins(0-default,1-custom):[0]
SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]
ZXAN(config)#
ZXAN(config)#
Personnel
Procedure
Personnel
Procedure
Personnel
Procedure
ZXAN(config)#interface shdsl_1/6/1
ZXAN(cfg-if-shdsl-1/1)# shutdown
ZXAN(cfg-if-shdsl-1/1)# no shutdown
Enabling subscriber port in batch.
ZXAN(config)# interface range shdsl_1/6/1-32
ZXAN(cfg-if-range-shdsl)# shutdown
ZXAN(cfg-if-range-shdsl)# no shutdown
Personnel
Procedure
Personnel
Procedure
Save the current working data to the configuration file of enabling data by the command
write.
ZXAN(config)#ex
ZXAN#write
Building configuration...
....[OK]
ZXAN#