Nothing Special   »   [go: up one dir, main page]

ZXA10 C300M (V3.1) SHDSL Service Commissioning Configuration Guide

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

ZXA10 C300M(V3.

1)SHDSL
Service Commissioning
Configuration Guide
ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

LEGAL INFORMATION

By accepting this certain document of ZTE CORPORATION you agree to the following terms. If you do
not agree to the following terms, please notice that you are not allowed to use this document.

Copyright © 2014 ZTE CORPORATION. Any rights not expressly granted herein are reserved. This
document contains proprietary information of ZTE CORPORATION. Any reproduction, transfer,
distribution, use or disclosure of this document or any portion of this document, in any form by any
means, without the prior written consent of ZTE CORPORATION is prohibited.

and are registered trademarks of ZTE CORPORATION. ZTE’s company name, logo
and product names referenced herein are either trademarks or registered trademarks of ZTE
CORPORATION. Other product and company names mentioned herein may be trademarks or trade
names of their respective owners. Without the prior written consent of ZTE CORPORATION or the
third party owner thereof, anyone’s access to this document should not be construed as granting, by
implication, estopped or otherwise, any license or right to use any marks appearing in the document.

The design of this product complies with requirements of environmental protection and personal
security. This product shall be stored, used or discarded in accordance with product manual, relevant
contract or laws and regulations in relevant country (countries).

This document is provided “as is” and “as available”. Information contained in this document is subject
to continuous update without further notice due to improvement and update of ZTE CORPORATION’s
products and technologies.

ZTE CORPORATION

Address: NO. 55
Hi-tech Road South
ShenZhen
P.R.China
518057
Website: http://dms.zte.com.cn(TSM-Technical Support)
Email: TSM.Aftersales@zte.com.cn

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. I


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

Revision History

Product Version Document Version Serial Number Reason for Revision


V3.1 R1.0 First issuing of SOP

Author

Prepared
Date Document Version Reviewed by Approved by
by
2013-06 R1.0 Yan Xiaohui Wang Jun

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. II


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

Applicable to: Partner/ZTE After-sales Engineers

Proposal: Before reading this document, you had better have the following knowledge and skills.
SEQ Knowledge and skills Reference material
ZXA10 C300M(V3.1) Multi-Service Access
1 Equipment commissioning
Equipment Configuration Manual

Follow-up document: After reading this document, you may need the following information
SEQ Reference material Information

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. III
ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

About This Document

Summary
Chapter Description
1 Overview
2 Overall Description of Procedure
3 Description of Each Step

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. IV


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

TABLE OF CONTENTS

1 Overview ......................................................................................................... 1
1.1 Usage Scale ..................................................................................................... 1
1.2 Objective .......................................................................................................... 1
1.3 Usage Method .................................................................................................. 1

2 Overall Description of Procedure .................................................................. 2


2.1 Flow Chart of SHDSL Service Commissioning.................................................. 2

3 Description of Each Step ............................................................................... 3


3.1 Preparing for SHDSL Service Commissioning .................................................. 3
3.2 Creating VLAN.................................................................................................. 4
3.3 Adding the Uplink Port to Service VLAN ........................................................... 5
3.4 Adding the User port to Service VLAN .............................................................. 5
3.5 Setting the PVID and PVC of User port............................................................. 6
3.6 Setting SHDSL Line Profile ............................................................................... 6
3.7 Setting SHDSL Alarm Profile ............................................................................ 7
3.8 Applying SHDSL Line and Alarm Profile ........................................................... 8
3.9 Enabling Subscriber Port .................................................................................. 8
3.10 Checking Data Configuration ............................................................................ 8
3.11 Saving Configuration ...................................................................................... 10

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. V


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

FIGURES

Figure 2-1 Flow Chart of SHDSL Service Commissioning .................................................... 2


Figure 3-1 SHDSL Access Service Network Diagram .......................................................... 3

TABLES

Table 3-1 SHDSL Access Service Data Specification .......................................................... 4

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. VI


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

1 Overview

1.1 Usage Scale


This document defines the standard operation procedure (SOP) of ZXA10 C300M
SHDSL service commissioning configuration.

1.2 Objective
This SOP is applicable to the debugging personnel engaged in fixed network ZXA10
C300M products.

1.3 Usage Method


SOP documents of fixed network products adopt the “SOP + operation guide + reference”
architecture.

1. SOP explains what needs to be done in which sequence in order to achieve a goal.

2. Operation guide explains how to perform the operation procedure, that is, how to do
in detail.

3. References are a supplement to SOP and operation guide.

Senior engineers can accomplish corresponding operations by referring to SOP


documents only; junior engineers need to refer to the operation guide and references.
The operation guide and references are defined in the input files of corresponding SOP
activities.

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 1


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

2 Overall Description of Procedure

2.1 Flow Chart of SHDSL Service Commissioning

Figure 2-1 Flow Chart of SHDSL Service Commissioning

Preparing for SHDSL Commissioning

Creating VLAN

Adding the uplink port to service VLAN with tag

Adding the user port to service VLAN

Setting SHDSL line and alarm template

Setting PVID and PVC of subscriber port

Applying SHDSL line and alram template to


subscriber port

(Optional) Enabling subscriber port

Error
Checking configuration

Correct

Saving configuration

Ending configuration

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 2


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

3 Description of Each Step

3.1 Preparing for SHDSL Service Commissioning


As to hardware preparations, please refer to system debugging SOP. This step requires
the preparation of each data for SHDSL service commissioning. The required data are as
follows.

1. VLAN planning: Plan the VLAN data for SHDSL service.

2. Port configuration planning: port information of relevant rate and the VLAN where
the port is on should be opened.

3. Port PVC planning: plan the PVC data interconnecting with MODEM.

Network Diagram

SHDSL service access network diagram is shown in Error! Reference source not
found..

Figure 3-1 SHDSL Access Service Network Diagram

INTERNET

BRAS

Ethernet Switch

1/21/1

C300M

1/6/1 1/6/32

MODEM MODEM

PC PC

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 3


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

Data Specification

SHDSL access service data specification is shown in Table 3-1.

Table 3-1 SHDSL Access Service Data Specification


Item Data
SHDSL service VLAN 200-231
The uplink port 1/21/1
Service port 1/6/1-32
Upstream: 1Mbps
Line rate profile
Downstream: 3Mbps
MODEM PVC 8/81
Ethernet Switch:
Ethernet Switch transparently transports the ZXA10
C300M service packet in layer–2 MAC frame.
Requirements on Configure ZXA10 C300M equipment access VLAN with
upstream equipment VLAN ID to be consistent with the ZXA10 C300M uplink
VLAN.
BRAS: Complete corresponding configuration according to
the requirements on dialing user authentication and billing.

3.2 Creating VLAN


Purpose

To create service VLAN

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

In config mode, use the command vlan x to create VLAN of SHDSL service.
ZXAN(config)#vlan 200
ZXAN(config-vlan)#exit
ZXAN(config)#vlan database
ZXAN(vlan)#vlan 200-231
ZXAN(vlan)#

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 4


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

3.3 Adding the Uplink Port to Service VLAN


Purpose

To add the uplink port to service VLAN with tag

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

Enter uplink interface mode and add it to the SHDSL service VLAN.
ZXAN(config)#interface gei_1/21/1
ZXAN(config-if)#switchport mode hybrid
ZXAN(config-if)#switchport vlan 200 tag
ZXAN(config-if)#exit
ZXAN(config)#
Configure VLAN in batch:
ZXAN(config)#interface gei_1/21/1
ZXAN(config-if)#switchport mode hybrid
ZXAN(config-if)#switchport vlan 200-231 tag
ZXAN(config-if)#exit

The uplink port mode should be consistent with the upper equipment port, if the upper
equipment port is tag mode, the uplink mode should be tag; if the upper equipment port is
untag mode, the uplink port mode should be untag.

3.4 Adding the User port to Service VLAN


Purpose

To set subscriber port mode

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

ZXAN(config-if)#switchport mode access


ZXAN(config-if)#switchport default vlan 200 pvc 1
ZXAN(config-if)#
Configure VLAN in batch:
ZXAN(config-if-range)#switchport mode access

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 5


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

ZXAN(config-if-range)#switchport default vlan 200-231 one-to-one pvc 1


ZXAN(config-if-range)#

3.5 Setting the PVID and PVC of User port


Purpose

To set the PVID and PVC of user port

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

1. Enter a single user port mode


ZXAN(config)#interface shdsl_1/6/1
ZXAN(cfg-if)#atm pvc 1 vpi 8 vci 81

2. Enter multiple user ports mode


ZXAN(config)# interface range shdsl 1/1-32
ZXAN(cfg-if-range)# atm pvc 1 vpi 8 vci 81

3.6 Setting SHDSL Line Profile


Purpose

To set SHDSL line Profile

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

Create SHDSL line configuration file, then set parameters.


ZXAN(config)#shdsl profile test //create SHDSL line configuration file, name is test
This profile does not exist. Would you like to create? [y/n][y]
ZXAN(config)#shdsl profile test //set parameters
SpanConfWireInterface:
[1]-twoWire
[2]-fourWire
[3]-sixWire
[4]-eightWire

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 6


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

[5]-gsfourWireBitInterleave
[6]-fourWireByteInterleaveEnhanced
[7]-fourWireBitInterleaveEnhanced
SpanConfWireInterface:[1]
SpanConfMinLineRate(192..30000kbps):[200]1000 //minimum line transmission rate
SpanConfMaxLineRate(200..30000kbps):[1552]3000 // maximum line transmission rate
SpanConfPSD(1-symmetric,2-asymmetric):[1]
SpanConfTransmissionMode(0-default,1-custom):[0]
SpanConfRemoteEnabled(1-enable,2-disable)):[1]
SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]
SpanConfCurrCondTargetMarginDown(0..10dB):[5]
SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]
SpanConfCurrCondTargetMarginUp(0..10dB):[5]
SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]
SpanConfUsedTargetMargins(0-default,1-custom):[0]
SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]
ZXAN(config)#
ZXAN(config)#

3.7 Setting SHDSL Alarm Profile


Purpose

To set SHDSL alarm profile

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

ZXAN(config)#shdsl alarm-profile test


This profile do not exist. Would you like to create? [y/n][y]
ZXAN(config)#shdsl alarm-profile test
EndpointThreshLoopAttenuation(-127..128dB):[128]
EndpointThreshSNRMargin(-127..128dB):[0]
EndpointThreshES(0..900s):[900]
EndpointThreshSES(0..900s):[900]
EndpointThreshCRCanomalies(0..100000):[900]
EndpointThreshLOSWS(0..900s):[900]
EndpointThreshUAS(0..900s):[900]
ZXAN(config)#

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 7


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

3.8 Applying SHDSL Line and Alarm Profile


Purpose

To apply SHDSL Line and alarm profile to user port

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

The process is shown as the following.


ZXAN(config)#interface shdsl_1/6/1
ZXAN(cfg-if)#shdsl profile test
Apply line configuration template in batch.
ZXAN(config)# interface range shdsl_1/6/1-32
ZXAN(cfg-if-range)# shdsl profile test

3.9 Enabling Subscriber Port


Purpose

To enable subscriber port

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

ZXAN(config)#interface shdsl_1/6/1
ZXAN(cfg-if-shdsl-1/1)# shutdown
ZXAN(cfg-if-shdsl-1/1)# no shutdown
Enabling subscriber port in batch.
ZXAN(config)# interface range shdsl_1/6/1-32
ZXAN(cfg-if-range-shdsl)# shutdown
ZXAN(cfg-if-range-shdsl)# no shutdown

3.10 Checking Data Configuration


Purpose

To check whether the data configuration is correct

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 8


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

Procedure

1. Checking service VLAN configuration


ZXAN(config)#show vlan summary
All created vlan num: 42
Details are following:
1-3,9-10,100-101,120,200-231,500,1000

2. Checking SHDSL line template

Generally, Base-profile, dpbo-profile, upbo-profile use default configuration, so we


only check service-profile configuration.
ZXAN(config)#show shdsl profile test
SpanConfWireInterface :twoWire
SpanConfMinLineRate :1000
SpanConfMaxLineRate :2000
SpanConfPSD :symmetric
SpanConfTransmissionMode :region 2 Indicates ITU-T G.991.2 A
nnex B.
SpanConfRemoteEnabled :enable
SpanConfPowerFeeding :noPower
SpanConfCurrCondTargetMarginDown :5
SpanConfWorstCaseTargetMarginDown :0
SpanConfCurrCondTargetMarginUp :5
SpanConfWorstCaseTargetMarginUp :0
SpanConfUsedTargetMargins :currCondDown
SpanConfReferenceClock :LocalClk
SpanConfLineProbeEnable :disable
ZXAN(config)#

3. Check line configuration file of subscriber port


ZXAN(config)#show shdsl port-info shdsl_1/6/1-32
Port Link Speed LinkRetrain LineProfile AlarmProfile
ADM/OPR UP/DOWN(kbps) Count
-----------------------------------------------------------------------
-------
6/01 up/down 0 0 test test
6/02 up/down 0 0 test test
6/03 up/down 0 0 test test
6/04 up/down 0 0 test test

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 9


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

6/05 up/down 0 0 test test


6/06 up/down 0 0 test test
6/07 up/down 0 0 test test
6/08 up/down 0 0 test test
6/09 up/down 0 0 test test
6/10 up/down 0 0 test test
6/11 up/down 0 0 test test
6/12 up/down 0 0 test test
6/13 up/down 0 0 test test
6/14 up/down 0 0 test test
6/15 up/down 0 0 test test
6/16 up/down 0 0 test test
6/17 up/down 0 0 test test
6/18 up/down 0 0 test test
6/19 up/down 0 0 test test
6/20 up/down 0 0 test test
6/21 up/down 0 0 test test
6/22 up/down 0 0 test test
6/23 up/down 0 0 test test
6/24 up/down 0 0 test test
6/25 up/down 0 0 test test
6/26 up/down 0 0 test test
6/27 up/down 0 0 test test
6/28 up/down 0 0 test test
6/29 up/down 0 0 test test
6/30 up/down 0 0 test test
6/31 up/down 0 0 test test
6/32 up/down 0 0 test test

3.11 Saving Configuration


Purpose

To save data configuration

Personnel

System debugging engineers that have passed Competence Certification Level-2 of


ZXA10 C300M

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 10


ZXA10 C300M(V3.1)SHDSL Service Commissioning Configuration Guide Internal Use O
nly▲

Procedure

Save the current working data to the configuration file of enabling data by the command
write.
ZXAN(config)#ex
ZXAN#write
Building configuration...
....[OK]
ZXAN#

ZTE Confidential Proprietary © 2014 ZTE CORPORATION. All rights reserved. 11

You might also like