RUVIS Systems: Krimesite™ Imager
RUVIS Systems: Krimesite™ Imager
RUVIS Systems: Krimesite™ Imager
Imaging System
KRIMESITE™ IMAGER Customers that are utilizing
The KRIMESITE Imager is a no-touch technology utilizing Reflected Ultraviolet KRIMESITE™ technology:
Imaging (RUVIS) to detect latent fingerprints without the use of powders or Alabama Bureau of Investigations
Arkansas State Police
chemicals. SIRCHIE ® provides various options to allow the user to search, Atlantic City Police Department, NJ
view, and capture latent prints and other evidence not visible to the unaided Baltimore City Police Department, MD
eye. With the use of shortwave UV (254nm UVC), the KRIMESITE is extremely Beverly Hills Police Department, CA
Birmingham Police Department, AL
versatile, allowing usage in various lighting conditions, and is ideal when Charlotte Police Department, NC
trying to identify the most evidence with the best available technology. Chicago Police Department, IL
Cincinnati Police Department, OH
Cook County Sheriff’s Police, IL
Denver Police Department, CO
Des Moines Police Department, IA
Detroit Police Department, MI
Federal Bureau of Investigation
Harrisburg Police Department, PA
Henry C. Lee Institute of Forensic Science, CT
Idaho State Police
Internal Revenue Service Forensic Lab, MD
Iowa Department of Public Safety
Jefferson Parish Sheriff’s Office, LA
Kansas Bureau of Investigations
Kentucky State Police
Massachusetts State Police
Miami Police Department, FL
Michigan State Police
Nashville-Metro Police Department, TN
New Jersey State Police
New Mexico State Police
New York Police Department Crime Lab, NY
North Dakota B.C.I.
Oklahoma State Bureau of Investigation
Palm Beach Police Department, FL
Philadelphia Police Department, PA
Phoenix Police Department, AZ
Pittsburgh Police Department, PA
Richmond Police Department, VA
Sacramento County Sheriff’s Department, CA
San Jose Police Department, CA
Sandia National Labs, CA
South Carolina Law Enforcement Division
St. Petersburg Police Department, FL
Suffolk County Sheriff’s Department, NY
Tennessee Bureau of Investigation
U.S. Air Force O.S.I. Headquarters
U.S. Army Crime Lab
U.S. Customs and Border Patrol Lab, CA
Virginia State Police
Washington D.C. Metro Police
Wyoming State Police Crime Lab
EDUCATION OPPORTUNITY!
We offer a RUVIS certification
course conducted at your facility
in the utilization of our RUVIS
technology and related products.
Cyanoacrylate-fumed
fingerprint on the
same soft drink can
be photographed
with a digital camera
Photograph of multicolored connected to the
Untreated metal filing cabinet soda can in natural light— KRIMESITE™ IMAGER.
photographed with a digital camera no visible fingerprint. No background colors!
connected to the KRIMESITE™ IMAGER.
KSS7997 SPECIFICATIONS:
Objective Lens:
• PSS100b 25mm quartz objective lens (wide- THREE CONFIGURATIONS OF THE CYCLOPS IMAGER
angle) w/integral 254nm filter
• Aperture: f/2.8 fixed
• Focus Range: ~14” to infinity within the
254nm wavelength band
Eyepiece (2x):
• Diopter Adjustment Range: +2 to –6
• Eye Relief: –15mm
• Interpupillary Adjustment: 55mm-70mm
Image Intensifier Tube: Head Mount Pistol Grip Hand-Held
• 18mm micro channel wafer w/min. useful
photocathode of 18mm dia., >/= 40 Lp/mm
typical, with built-in over-
brightness protection circuitry
Pistol Grip (soft foam, detachable)
Batteries: 2 AA Alkaline Batteries (included)
Head Mount Assembly (Adjustable)
Laser Pointer, Class IIIa w/batteries
Dimensions (with pistol grip): 6.25”W x 8”H x
6.125”D (15.9cm x 20.3cm x 15.5cm)
Weight: 1 lb. 5 oz. (595.34g) w/batteries
KSS7900 CONTENTS:
1- KSS7997 CYCLOPS w/PSS100b 25mm
Quartz Objective Lens w/integral 254nm filter
1- Pistol Grip, detachable
1- Head Mount Assembly w/carrying pouch
10- AA Alkaline Batteries
1- KSS9696 Class IIIa Laser Pointer w/batteries
1- CUV100TS UV Mini Light Source (4-watt
254nm shortwave, battery operated)
1- UVP600ST UV Panther AC/DC Shortwave
Light, 254nm
2- 797GV UV Protective Spectacles
1- Operator’s Manual
1- Pelican® 1550 Carrying Case, Custom-fitted,
moisture resistant; Dimensions: 21”W x CATALOG NO. DESCRIPTION PRICE
9”H x 16.5”D (53.3cm x 22.9cm x 41.9cm);
Weight: 14.55 lbs. (6.6kg) KSS7900 CYCLOPS Imaging System w/25mm UV Lens
SHOP
Obtain the greatest efficiency at crime scene processing using the KRIMESITE™ and Cyclops
Imagers. (Both are contained in the Master RUVIS Kit.) ONLINE
www.sirchie.com
CATALOG NO. DESCRIPTION PRICE
KSS60MRK KRIMESITE™ IMAGER Master RUVIS Kit
DESKTOP COMPUTER
SPECIFICATIONS:
• Windows 7 32-bit, or Windows 7 64-bit
• Intel Core i3 3.3 Ghz processor
• 4 gigabyte (GB) of system memory
• 500 GB SATA Hard Drive
Minutely adjust focus and set f-stop for precise Precisely increase or decrease the lens-to-subject
• DVD/CD-ROM drive exposure with Labkam’s high quality optics. distance using the column height adjustment wheel.
• 23” monitor with 1920 x 1080 resolution
• Dedicated GigaNET Base T Network CATALOG NO. DESCRIPTION PRICE
Interface Card
LABKAM Laboratory Video-Based RUVIS Capture System (1000 PPI)
Cyanoacrylate-Fumed Prints:
Larger objects of interest can be scanned for
prints by both raising the RUVIS imager and
extending it’s distance from the Labkam’s copy
stand column.
RUVIS COMPANION
SKSUV13 SPECIFICATIONS: LABORATORY
• Construction: Rugged ABS plastic
• UV Lamp: 13-watt, 254nm, germicidal
ILLUMINATOR
• Swinging Lamp Head: 180 degrees
Portability and utility are the
* Internal ON/OFF Switch: lamp illuminates most outstanding features of
when head is raised the Companion Laboratory
• Power: 110V AC Illuminator. This 110V AC UV
• Dimensions: illuminator uses a 13-watt
10.5”H x 3.25”D x 3.4”W (27.67cm x 254nm germicidal lamp. The
8.25cm x 8.63cm)
illuminator automatically
• Weight: 2.3 lbs. (1.04kg)
turns on by lifting the head. It
is capable of swinging 180°,
easily accommodating a
variety of usage situations. The lamp head lifts away from the
housing allowing for up to a 180° swing
UV PROTECTIVE SPECTACLES
Top and side shield design provides full
protection from harmful shortwave UV
radiation emitted from UV and mercury
lamps, and eliminates “blue haze” from
longwave UV. Polycarbonate construction
and impact-resistant.
UV PROTECTIVE GOGGLES
Constructed of specially formulated plastic
which blocks UV transmission over all UV
wavelengths and provides optimum contrast
in viewing and lessened eye fatigue. A CAUTION:
lightweight design with flexible rubber trim The light sources used with RUVIS
technology emit shortwave (UV)
fits comfortably on the face—even over radiation. Use of these devices
prescription glasses. requires proper eye and skin protection
as afforded by the UV Protection
CATALOG NO. DESCRIPTION PRICE Products shown on this page.
ARROW DESIGNATORS
Use arrow designators in conjunction with the KRIMESITE™ IMAGER
mounted laser pointer for temporarily indicating latent fingerprint locations
or selected target areas.
CATALOG NO. DESCRIPTION PRICE
KSS684 Arrow Designators, 100 each