S100Pro GSM Alarm Manual V1.0
S100Pro GSM Alarm Manual V1.0
S100Pro GSM Alarm Manual V1.0
Advanced
Programmable
Multifunctional
GSM AutoDialer
GSM Alarm Panel
In The Worldwide!
GSM Alarm
User Manual
S100Pro
Ver 1.0
Table of Contents
1. Brief introduction ---------------------------------------------------------------------------------------------------3
2. Safety Directions --------------------------------------------------------------------------------------------------3
3. Standard Packing list ----------------------------------------------------------------------------------------------4
4. Mainly Features----------------------------------------------------------------------------------------------------4
5. Installation and Connection Diagram ---------------------------------------------------------------------------------5
6. Function Programming------------------------------------------------------------------------------------------------7
7. Operating Instructions -----------------------------------------------------------------------------------------------17
8. Wireless Detectors activated method -------------------------------------------------------------------------------21
9. Technical specifications --------------------------------------------------------------------------------------------22
10. Maintenance----------------------------------------------------------------------------------------------------------23
11. Quality Warranty ---------------------------------------------------------------------------------------------------23
12. Affix Table------------------------------------------------------------------------------------------------------------23
Table 1. S100Pro Installation Schedule
Table 2. S100Pro Program and Operation Code List
This handbook has been designed as a guide to the installation and operation of GSM Alarm System S100Pro
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the
instructions contained with other products.
We recommend that the advice of a registered electrician be sought before any Installation work commences.
The manufacturer, its employees and distributors, accept no liability for any loss or damage including consequential
damage due to reliance on any material contained in this handbook.
The manufacturer, its employees and distributors, accept no liability for GSM Network upgrading or SIMCard
upgrading due to the technology specifications contained in this handbook.
*The commands should plus Password, the format is Password+SMS Command. i.e.: if the password is 1234, then
you can send 1234AA to arm, 1234BB to disarm, the AA~EE must be Caps Lock.
1. Brief introduction
The GSM Alarm System S100PRO is a cost effective, reliability, multi-functions, metallic pigment luxury
appearance, and user friendly Home Security Alarm System. It integrated quad-band GSM module inside,
voice broadcast for settings and operations, two way voice communication, AC power and backup battery
status monitoring, LCD display, 8 wired zones and 96 wireless zones for different detection requirements,
multi-modes for Stay, Away, SOS and 24 hours, timer to armed or disarmed, supports auto-dial 6 numbers
and send SMS Alarm alert to 4 mobile numbers once alarm occurrence.
In one word, the GSM Alarm System S100Pro includes almost all useful functions and features of the
alarm systems in the worldwide markets. Also it with innovative and experienced functions and features to
meet the required and potential demands. Like smart phone apps iOS ikeypad, Android Apps ikeypad and
so on.
2.Safety Directions
Safe Startup
Do not use S100Pro when using GSM equipment is prohibited or might bring disturbance or
danger.
Interference
All wireless equipment might interfere network signals of S100Pro and influence its
performance.
Reasonable Use
Please install the product at suitable places as described in the product documentation.
Avoid signal shielded by covering the mainframe.
4. Mainly Features
¾ GSM Frequency: Quad-Band (850/900/1800/1900Mhz) ;
¾ Supports Away, Stay or disarmed, SOS by remote control or keyboard;
¾ Supports Away, disarmed,switch on or off Siren by SMS Commands or smart apps;
¾ Supports Away,Disarmed, switch on or off siren, listen onsite by call in;
¾ Automatically send SMS Alert to 4 mobile phone numbers and dial to 6 telephone number once alarm
occurrence;
¾ Supports 96 Wireless Zones and 8 wired zones for different detection requirements;
¾ Voice broadcast for programming and operations;
¾ 10 seconds recordable voice can be played once call out caused by alarm occurrence;
¾ 40 Alarm Records for user review;
¾ Learning code for programming wireless detectors;
¾ Supports Timer for automatically arm or disarm the system;
¾ Supports armed delay to give enough time to you go out the home, the delay time is editable by user;
¾ The Keypad can use as a dialer, the functions like the telephone;
¾ Standby internal rechargeable battery which can last 12 hours;
¾ AC Power and backup battery status monitoring and alert by SMS;
LCD display:
6. Function Programming
Tips:
The Administrator password is for setting the parameters, the User password is for operating the units
after setup. Can not setup the administrator password the same as the user password.
6.1 Initialization
Please insert SIM card and insert the adapter output terminal into the power hole of the host, and then
power on the system. It will show the GSM alarm system is good when built-in buzzer rings again per
second with the signal light flashing again per second, and about 15 seconds a long ring with the signal “five
lattice” on the screen. The signal lights flash every one seconds if the alarm system is good.
Last, please turn on the backup battery switch.
6.2 System setting
In the state of disarm, input 4- digit administrator password by the keypad on the host and press [#] button
to confirm. You will hear a voice prompt: please enter instruction. At the same time,[set] indicator is on
without flashing and [- - - -]displays on the screen, indicating the system enters setting status. You can
perform different settings repeatedly as long as the system keeps in setting status. The system will exit
setting mode and return to disarm status. The system will exit setting mode and return to disarm status if
you don't press any keypad button for 40 seconds.
Note: The default administrator password is [6666].
Operating method: [XXXX] Ö[#]
X indicates: 4-digits administrator password.
LCD display:
Note: when you need to change the content of recording, just store your new one.
6.19 Modify Passwords
***Change User Password
User password is the key to enter the host operating system when start Disarm or Remote Control.
In setup state, use keypad to input [38], then input the 4- digit new password, finally press [#] to confirm. The
main unit will make a long beep and you will hear a voice prompt “ setting completed”.
Operating :[38]Ö[XXXX]Ö[#]
XXXX indicates:the new 4-digit password
Example: change the system password to 1012;
Operating: [38]Ö[1012]Ö[#]
LCD display:
Note: The user password and the Administrator password cannot be the same.
6.20 Keypad lock setting
In setup state, press [40], then input [0~1], finally press [#] to confirmed. The host makes a long beep. A
“setting completed” voice prompt appears.
Operating: [40]Ö[X]Ö[#]
X=“0” indicates: Keypad unlock .while Arm/Disarm/Stay by the keypad will not require enter
password.
X=“1” indicates: Keypad lock. While Arm/Disarm/Stay by the keypad, will require enter
password.
Example: Open the keypad lock function.
Operating: [40]Ö[1]Ö[#]
LCD display:
6.28 The 1st and 2nd SMS Alert Phone Number Setting
In setup state, enter [49~50], then input phone number, finally press [#] to confirm. The host makes a long
beep, the [signal] flashes at the same time. You will hear a voice prompt: setting completed.
Delete Phone the 3rd SMS Alert Phone number: [57]Ö [#]
6.31 Defense Zone Alarm Type Setting
In setup state, first press the host keypad to input address code [60] , choose the corresponding defense zone code [02]
~ [97] , and then input [1 ~ 8] defense zone alarm type, finally add [#] key to confirm. Voice prompt: setting completed .
Operating: 【60】Ö【XX】Ö【 A 】Ö【 # 】
XX indicates defense zone code: [02] ~ [97] , matching 02 to 97 defense zones correspondingly.
A stands for Alarm Type: [1] SOS Alarm, [2] fire alarm, [3] gas leak alarm,[4] door lock alarm, [5] hall alarm, [6] window
7.Operation Instructions
Tips!
1. The user can arm/disarm/Stay (Partial armed) by Remote Control, Dial in, and, SMS, Another, the user can switch
on or off the Siren by SMS Commands.
2. Mode explanation
Armed: Away, In this mode, any detector triggered will cause alarm. It be used for away the home and need to
protect all of the home or office or store,etc.
Stay: Partial armed, at home, in this mode, only the outer zones and emergency zones triggered will cause alarm,
the inner zone triggered will not cause alarm. It be used for partial armed, e.g.: some people at home, and need to
monitoring the outer security.
Disarmed: Except the 24 Hours emergency zones triggered will cause alarm, all of the other zones triggered will
not cause alarm. Usually for maintain or other special requirements.
3. Alarm Occurrence
1) When alarm occurrence, the S100Pro will send out Alarm SMS Content firstly, then automatically dial the
authorized numbers one by one, if picked up the call, the S100Pro will stop to sound and prompt voice menu
for operation, If nobody picked up or rejected, the S100Pro will dial all of the authorized numbers 3 times in
cycle then stop to dial any more. Meanwhile, the S100Pro will enter to previous status.
7.1 Main Host Status
System status: There are 4 status types as follows:
1) Away Arm: Defense zone 02-97 will alarm when detectors are triggered
2) Stay(At Home): The defense zone which is set as [Stay], when detectors are triggered.
3) Disarm: Defense zone 02-97 will not alarm when detector triggered (except 24 hours defense zone).
4) System setup status: In this status, all defense zones will not alarm when detectors are triggered.
Press [ ] button on keypad, system will make a beep per second and totally 100 beeps. The [ ]
The Host Operating: [ ] (keypad lock is closed or [ ] + [user password] + [#] (keypad lock is open)
LCD display:
7.4 Stay
It means, for the safety, while somebody is at home, you need to enable the peripheral: door, window,
balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors,
which may cause improper warning; then, you shall select Stay, let just part of the detectors work and
disable the other parts.
Press the Stay Button on the keypad.
LCD display:
7.5 Disarm
It means to stop the alarm when the host sounds the alarm or makes the alarm system in the state of
non-warning. After disarming, even if you trigger the detector, the host would not sound alarm (excluding
24- hour defense areas).
If keypad lock is closed, press [ ] on keypad directly to disarm. If keypad lock is open, press [ ], and
follow voice prompt enter [user password, finally press [#] to confirm. [Out home] or [Home] signal light is off.
Disarming operation is completed.
Remote Control Operation: Press [ ].
LCD display:
xxxxAA Example
“xxxx” stands for the user 1234AA
password (4 digits).
Return SMS When the Password is 1234
Armed
Disarm
xxxxBB Example
“xxxx” stands for the user 1111BB
password (digits).
Return SMS When the Password is 1111
Disarmed
xxxxCC Example
“xxxx” stands for the user 1111CC
password (4 digits).
Return SMS When the Password is 1111
Siren ON.
xxxxDD Example
“xxxx” stands for the user 1111DD
password (4 digits).
Return SMS When the Password is 1111
Siren OFF.
Inquiry Status
xxxxEE
“xxxx” stands for the user password (4 digits).
Return SMS
Armed or Disarmed
AC Power ON or AC Power off.
Enter phone number, then press [ ], main host makes a long beep, [signal]light starts flashing at the
same time. Call completed, press [ ], hang up, Main host will be in disarming state.
9. Technical specifications
Rated Voltage: 12VDC 2A
Standby current: Less than 50mA
Working Current: Less than 435mA
Working temperature: -10℃~+60℃
Storage temperature: -20℃~+60℃
Relative humidity: 10-90%, No condensation
10. Maintenance
1) In case of failure, please contact the distributor or manufacturer.
2) If the remote control works, but the S100Pro fails to send SMS texts, switch the power of S100Pro off
and switch it on after one minute. Test this system after another minute, or check the settings are
correct and the GSM Signals are strong enough.
3) If the S100Pro can run and sensors work, but cannot send SMS texts, please change SIM Card to
check it.
4) If the problem cannot be solved, please contact the distributor or manufacturer.
11. Warranty
1) This system is warranted to be free of defects in material and workmanship for one year.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the
Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by
purchasers.
S100Pro Installation Schedule
User Defined Value of Zones
Zone No.
Sensor Name Zone Attribute Code Sensor Alarm Type Installation Place
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
S100Pro Authorized Number Schedule
SIMCard Number in the S100Pro: ___________________
Auto Dial Phone Number SMS Alert Phone Number
SN User Name Phone Number SN User Name Phone Number
1 1
2 2
3 3
4 4
5 User Password
6 Administrator Password
Notice: Please mark V if for enable and X for disable.