PD 1096 PD 1185 PD 957 BP 220 BP 220 BPP 344 Uniform Building Graphic

SUBJECT
Building Code Fire Code Condominium Law Economic Housing Socialized Housing Accessibility Law Code Standards

Minimum Requirement for


Residential Dwellings:

Dwelling Location and


Lot Occupancy

Corner Lot shall occupy ≤ 90% N/A N/A N/A N/A N/A N/A N/A
of the lot
Inside Lot shall ocuupy ≤ 80% N/A N/A N/A N/A N/A N/A N/A
of the lot
Foundation at least .25m thick and N/A N/A N/A N/A N/A N/A refer to building code
.6m below the surface of
the ground
Occupant Load 18.5 sq. m./ person N/A 18.5 sq. m./ person no. of units multiply by 6 no. of units multiply by 6 N/A N/A N/A
Live Load at the 1st Floor at least 200 kg. per sq. m. N/A N/A N/A N/A N/A N/A N/A
Live Load at the 2nd Floor at least 150 kg. per sq. m. N/A N/A N/A N/A N/A N/A N/A
Stair Width at least .75m N/A 1.10m .6m .6m N/A .914m 1.118m
Stair Riser ≤ .2m N/A .2m .2m .2m N/A .178m .102m
Stair Tread at least .2m N/A .25m .25m .25m N/A .279m .279m
Entrance and Exit at least 1 entrance N/A at least 1 entrance at least 1 entrance at least 1 entrance N/A at least 1 entrance N/A
and 1 exit and 1 exit and 1 exit and 1 exit and 1 exit
Light And Ventilation
Minimum Dimension of 2.00m N/A 1.50m 2.00m 2.00m N/A 3.048m N/A
Court
Passageway from atleast 1.20m N/A at least 1.20m at least 1.20m at least 1.20m N/A at least .914m N/A
Inner Court
Minimum Height Clearance 1.00 above the roof N/A 1.00m above the roof 1.00m above the roof 1.00m above the roof N/A N/A N/A
of Firewall
Headroom Clearance 2.00m 2.00m 2.00m 2.00m 2.00m N/A 2.032m 2.00m
Minimum Ceiling Height for 2.40m for artificial vent. & 2.30m 2.40m for artificial vent. 2.40m 2.40m N/A 2.438m refer to building code
Habitable Rooms 2.70m for natural vent. 2.70m for natural vent.
Minimum Ceiling Height for 2.70m for the 1st storey 2.30m 2.00m 2.00m 2.00m N/A 2.438m refer to building code
Buildings 2.40m for the 2nd storey 2.13m 1.80m for mezzanine 1.80m for mezzanine 1.80m for mezzanine 2.134m for mezzanine
2.10m headroom floors floors floors floors
clearance for the
succeeding storey
1.80m for mezzanine floors
Sum of the Areas of such < 50% of the total area of N/A <50% of the total area of <25% of the total area of <25% of the total area of N/A < 50 % of the total area of N/A
Opening in any Storey the wall in the storey the wall in that storey the wall in that storey the wall in that storey the wall in that storey
Window Openings at least 10% of the floor N/A at least 10% of the floor at least 10% of the floor at least 10% of the floor N/A at least 20% of the N/A
area area area area perimeter wall area
Eaves Over Required ≥ .750m N/A N/A N/A N/A N/A ≥ .762m N/A
Windows
Size and Dimension
of Rooms
Rooms for human habitation 6.00sqm with a least N/A 18.00sqm for a studio N/A N/A N/A not less than 11.20sqm refer to building code
dimension of 2.00 unit
Kitchens 3.00 sqm with a least N/A N/A N/A N/A N/A not less than 6.50sqm with refer to building code
dimension of 1.50m a least dimension of 2.134m
Toilet and bath 1.20 sqm with a least N/A N/A N/A N/A 2.25sqm with a N/A refer to building code
dimension of 0.90m minimum dimension
Building Projections Over
Public Streets
Clearance between the
street and/or sidewalk and ≥ 3.00m N/A N/A N/A N/A N/A N/A N/A
the lowest undersurface of
the balcony
Canopy horizontal clearance ≥ .300m between the
outermost edge and the
curb line
Canopy vertical distance ≥ 3.00m between the N/A N/A N/A N/A N/A N/A N/A
pavement and the lowest
undersurface of the
canopy
Enclosure of Vertical
Openings
Draft curtain at least .300m from the .510m N/A N/A N/A N/A N/A N/A
ceiling downward
Provision of automatic .006 m around the N/A N/A N/A N/A N/A 1.829m center to center N/A
sprinklers perimeter of the opening
and within the draft
curtain 1.80m center to
center
Exits
Building with an occupant at least 1 exit not less than 2 at least 1 exit at least 1 exit at least one exit N/A N/A N/A
load <10 exits
Building with an occupant at least 2 exits N/A at least 2 exits N/A N/A N/A N/A N/A
load ≥ 10 to 499
Building with an occupant at least 3 exits N/A at least 3 exits N/A N/A N/A N/A
load ≥ 500 to 999 N/A
Building with an occupant at least 4 exits N/A at least 4 exits N/A N/A N/A N/A
load 100 or more
Distance to exits without ≤ 45. from exit door ≤ 46m from exit ≤ 45m from exit door ≤ 45m from exit door ≤ 45m from exit door N/A ≤ 45.720 from exit door N/A
sprinklers system door
Distance to exits with ≤ 60m from exit door ≤ 61m from exit ≤ 60m from exit door ≤ 60m from exit door ≤ 60m from exit door N/A ≤ 60.960 from exit door N/A
sprinklers system door
Minimum exit door width/ .700m .70m .700m .800m .800m N/A N/A N/A
access

Minimum door width for .900m .810m .900m .600m .600m .800m 6.10m .600m
habitable rooms
Minimum exit door height 2.00m 2.00m 2.00m 2.00m 2.00m N/A N/A N/A
Minimum width corridor 1.10m .550m 1.10m 1.20m 1.20m 1.20m 1.118m N/A
Maximum slope of exit 1 in 8 N/A 12.1 in 8 1 in 8 1 in 8 N/A N/A N/A
passageway
Dead ends 6.00m in length 6.00m in length 12.00m in length 12.00m in length N/A 6.096m in length N/A N/A
Stairways for Buildings
Minimum stair width for an .750m N/A N/A N/A N/A N/A N/A
occupant load less than 10
Minimum stair width for an .900m N/A .900m .900m N/A .914m N/A
occupant load less than 50
Minimum stair width for an 1.10m N/A 1.19m 1.00m N/A 1.118m N/A
occupant load more than 50
Maximum rise of step .200m .0019m-class A .200m .200m N/A .178m .102m
.200m-class B
Minimum run of step .250m .250m-class A .250m .250m N/A .279m .279m
.230m-class B
Minimum width of stairs 1.10m 1.12m 1.10m .600m N/A .914m 1.118m
Maximum distance between 3.60m vertically 2.75m-class A 3.60m vertically 3.60m vertically N/A 3.658m vertically 3.7326m
landings 3.70m-class B
Minimum dimension of equal to the width of the 3.66m equal to the width of the equal to the width of the N/A 1.118m 1.118m
landings in the direction of stairway stairway stairway
travel
Minimum height of handrails .800m from the nosing of .760m from .800m from the nosing of .800m from the nosing of .700m from the floor .864m from the floor .869m from the floor
the tread the nosing of the tread the tread
the tread
Maximum height of .900m from the nosing of .865m from the .900m from the nosing of 1.20m from the nosing of .900m from the floor .965m from the floor N/A
handrails tread nosing of the the tread the tread
tread
Sidewalks and Arcades
Minimum width of sidewalks 1/6 of the road-right-of- N/A 1.00m for major and 1.00m for major and N/A 1.118m N/A
minor roads .500m for minor roads
way N/A 1.00m for major and 1.00m for major and N/A N/A N/A
Planting strip .800m in width for minor roads .500m for minor roads
sidewalks
2.00m or more in width
Minimum vertical clearance 3.00m N/A 3.00m N/A N/A N/A N/A
of arcades
Maximum vertical clreance 6.00m N/A 6.00m N/A N/A N/A N/A
of arcades
Requirements for arcades shall be cantillevered N/A N/A N/A N/A N/A N/A
from building line over the
the sidewalk, and the
horinzontal clearance
between the curb curb line

and the outer-most face of


any part of the arcade
shall not be less than
.500m
Combined open and arcades shallbe provided with N/A N/A N/A N/A N/A N/A
sidewalk planting strip of not less
than .800m in width as a
separating strip between
the arcaded portion and
open portion of the
sidewalk
Grade of sidewalks as much as possible, be N/A N/A N/A N/A N/A N/A
level uniform grade
throughout the entire
length of the street
Driveways, Entrance and
Exits
Slope of entry ramp on the 1 in 3 to 1 in 4 N/A N/A N/A N/A N/A N/A N/A
driveway connecting to the
roadway surface of the
sidewalk
Maximum slope of ramps 1 in 10 10% 1 in 10 15% 15% 1:12m-the length of 1:12m N/A
the ramp ≥ 6.00m
Gradient of Sidewalks
Whenever the slope of the the sidewalk should be N/A N/A N/A N/A N/A N/A N/A
street is 1 in 10 maintained level for every
20.00m to 40.00m
Sidewalks of different levels shall be joined by means slope may be N/A N/A N/A N/A N/A N/A
of a ramp having any used where
convenient slope not the difference
exceeding 1 in 6 in elevation
is greater than
.5334m
Access Street/Roads
and Alleys
for multiple units on
the same lot
up to 6 units 3.00m wide N/A N/A N/A N/A N/A N/A N/A
7 units up to 15 4.00m wide N/A N/A N/A N/A N/A N/A N/A
16 units up to 25 units 5.00m wide N/A N/A N/A N/A N/A N/A N/A
26 up to 35 units 6.00m wide N/A N/A N/A N/A N/A N/A N/A
more than 35 units 7.50m wide N/A N/A N/A N/A N/A N/A N/A
Roads Right-of-way
Major roads N/A N/A 12.00m ROW 10.00m ROW 10.00m ROW N/A N/A N/A
8.00m carriageway 6.00m carriageway 6.00m carriageway
Minor roads N/A N/A 10.00m ROW 8.00m ROW 8.00m ROW N/A N/A N/A
6.00m carriageway 6.00m carriageway 6.00m carriageway
Motor court (cul-de-sac, Minimum radius is 9.15 6.00m ROW 6.00m ROW 6.00m ROW N/A N/A N/A
branch, loop, "tee") Carriageway is 3.35
Access road is 3.00m
Alley N/A N/A 4.00m ROW 3.00m ROW 3.00m ROW N/A 6.00m ROW N/A
Footpath/pathwalk N/A N/A N/A 3.00m ROW 3.00m ROW N/A N/A N/A
ROW of access to interior lot N/A N/A 3.00m ROW 3.00m ROW 3.00m ROW N/A N/A N/A