Nothing Special   »   [go: up one dir, main page]

Kompass - Aircrete Building Materials EN Print

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Loads

Permissible loads 1) in kN for a single anchor


Anchor type Anchorage depth Aircrete blocks Non-cracked aircrete panels Cracked aircrete panels (wall,
hef [mm] (wall, ceiling and roof panels) ceiling and roof panels)
Minimum compressive strength
2 4 3.3 4.4 3.3 4.4
fb [N/mm2]

Injection system FIS V


FIS V in conical drill hole (ETA-10/0383), with cone drill PBB, valid for temperature range -40 °C to +80 °C and dry masonry (d/d)
M8, M10 and M12 75 0.71, (0.89)2) 1.07, (1.61)2) – –
For anchorage in non-cracked
M8, M10 and M12 95 0.89, (0.89)2) 1.25, (1.61)2) aircrete panels, the values from –
the aircrete blocks column can be
FIS E 11x85 M6,
85 0.71, (0.89)2) 1.07, (1.61)2) used as "recommended loads". – –
FIS E 11x85 M8

Injection system FIS V


FIS V in cylindrical drill hole (ETA-10/0383), , valid for temperature range -40 °C to +80 °C and dry masonry (d/d)
M6 100 0.54, (0.43)2) 0.54, (0.71)2) – –
M8 100 0.54, (0.43)2) 0.71, (0.71)2) – –
M10 100 0.54, (0.43)2) 1.07, (0.71)2) For anchorage in non-cracked – –
aircrete panels, the values from
M12 100 0.71, (0.54)2) 0.89, (0.89)2) – –
the aircrete blocks column can be
M16 100 0.71, (0.43)2) 0.71, (0.71)2) used as "recommended loads". – –
FIS E 11x85 85 0.54, (0.43)2) 0.71, (0.71)2) – –
FIS E 15x85 85 0.54, (0.43)2) 0.54, (0.71)2) – –

When dimensioning, observe the approval certificate ETA-10/0383 in its entirety. Permissible edge distances and spacing and the minimum member thickness hmin should be taken from the approval.
Aircrete anchor FPX-I (ETA-12/0456)
M6–M12 70 0.40 0.89 0.80 1.20 0.60 0.80
When dimensioning, observe the approval certificate ETA-12/0456 in its entirety. Permissible edge distances and spacing and the minimum member thickness hmin should be taken from the approval.

Frame fixing SXRL 10 (ETA-07/0121), SXRL 14 (ETA-14/0297)


SXRL 10 70 0.27 0.71 – –
For anchorage in non-cracked
SXRL 10 90 0.32 0.89 aircrete panels, the values from – –
SXRL 14 70 0.32 0.89 the aircrete blocks column can be – –
used as "recommended loads".
SXRL 14 90 0.43 1.07 – –
When dimensioning, observe the approval certificates ETA-07/0121 and ETA-14/0297 in their entirety. Permissible edge distances and spacing and the minimum member thickness hmin should be taken from the approval.

Aircrete anchor GB with fischer safety screw (Z-21.2-123)


GB 8 50 0.20 0.40 – –
For anchorage in non-cracked
GB 10 55 0.25 0.60 aircrete panels, the values from – –
the aircrete blocks column can be
GB 14 75 0.40 0.90 used as "recommended loads". 0.30 0.30

When dimensioning, observe the approval certificate Z.21.2-123 in its entirety. Permissible edge distances and spacing and the minimum member thickness hmin should be taken from the approval.

Recommended loads3), 4), 5) for a single anchor


universal anchor UX (without approval)
UX 6x50 50 0.06 0.20 0.08 0.20 – –
UX 8x50 50 0.11 0.30 0.15 0.30 – –
UX 10x60 60 0.16 0.40 0.22 0.40 – –

1)
The partial safety factors of the resistances and a partial safety factor of the effect of F = 1.4, which are regulated in the approval, are considered.
2)
Values in brackets apply for the approved shear load, see ETA-10/0383
3)
Applies to tension load, shear load and diagonal pull under each angle
4)
Contains safety factor 7
5)
Load values apply when using with wood screws:
UX 6 with screw diameter 5 mm
UX 8 with screw diameter 6 mm
UX 10 with screw diameter 8 mm

XXXXXX-(1)-brochure_aircrete-building-materials-EN.indd 1 15.09.2015 10:53:14


What is aircrete?

The building material "aircrete" is commonly known as


aerated concrete. Aircrete is a solid building material with
porous microstructures; the building material has a lot of
pores (air pockets) and a low compressive strength.
Aircrete has the disadvantage that it takes on moisture
a lot quicker than it releases it; as such, external walls
made from aircrete must always be covered with a layer
of plaster or a different "skin".
As a result of the low compressive strength and the po-
rous microstructures, special care should be taken when
drilling holes and cleaning drill holes.
Special anchors should be used for the best anchorage
in aircrete, e.g. anchors with a long expansion part (SXRL
10 or 14) or anchors with interlocking or adhesive bonds
(FPX-I or FIS V injection systems).

Our all-round service for you.


We are a reliable partner, one that will stand by your side and
address your individual requirements with advice and action:
 Our products range from chemical systems and
steel anchors to plastic anchors.
 Competence and innovation through own research

536022 · 09/2015 · V-DM · Printed in Germany · Right to make technical changes reserved
and development.
 Global presence and active sales service in more
than 100 countries.
 Qualified application-specific advice
for economic installation solutions that are compliant
with directives. If need be we are there for you – even
at the construction site.
 Training measures (some with certification) at your
premises or at the fischer ACADEMY.
 Construction and design software for challenging fixings.

fischer Deutschland Vertriebs GmbH


Klaus-Fischer-Straße 1 · 72178 Waldachtal
Germany
Tel. +49 7443 12-6000 · Fax +49 7443 12-8297
www.fischer.de · info@fischer.de

XXXXXX-(1)-brochure_aircrete-building-materials-EN.indd 2 15.09.2015 10:53:21


536022 · 09/2015 · V-DM · Printed in Germany · Right to make technical changes reserved

fischer fixing compass


Aircrete.

XXXXXX-(1)-brochure_aircrete-building-materials-EN.indd 3 15.09.2015 10:53:24


Our aircrete professionals safely
ensure the very best hold.

Injection system FIS V Maximum load-bearing capacity


Conical drill hole: 1.25 kN (125 kg)
Our strongest solution for aircrete.
Cylindrical drill hole: 1.07 kN (107 kg) ETA-10/0383
ETAG 029
Masonry
Use categories b, c or d
and d/d or w/w

fischer high-performance mortar FIS V – bonds the anchor part to a


conical or cylindrical drill hole in the aircrete and allows for heavy loads
■ Highest loads in conical undercut drill holes – use fischer cone drill bit
■ Reduced load-bearing capacity in cylindrical drill holes – use standard
drill bit – push-through installation possible Conical drill hole
■ Non-bearing plaster layers can be easily bridged
■ Approved for aircrete masonry
■ Full load-bearing capacitiy after mortar curing time – HIGH SPEED mortar
after just 30 minutes

Cylindrical drill hole

Designs Type of installation


System can be used with:
ned inst ough insta ff install
itio hr d-o a

lla
s

all

n
Push-

tio
Pre-po

Sta
ation

tion

n
Cone Metric anchor rod FIS A Metric internal thread anchor FIS E
for internal and for internal use with
drill PBB to external use metric screws and anchor rods
create an
undercut

Aircrete anchor FPX-I


The instantly and high load-bearing internal Maximum load-bearing capacity: 1.20 kN (120 kg)
thread professional for aircrete.

fischer aircrete anchor FPX-I with internal thread – ensures a strong


hold thanks to the self-undercutting technology
■ High loads thanks to the self-undercutting technology – the drill hole is
created with a standard drill bit
■ Simple and innovative screw installation with automatic setting control
■ Approved for aircrete masonry and aicrete ceiling panels
■ Can be loaded immediately after installation

Type Type of installation

ned inst ff install


itio d-o a
s

all

tio
Pre-po

Sta
ation

Aircrete anchor FPX-I with metric internal thread for indoor applications with metric screws
and anchor rods

XXXXXX-(1)-brochure_aircrete-building-materials-EN.indd 4 15.09.2015 10:53:48


Aircrete anchor GB Maximum load-bearing capacity: 0.90 kN (90 kg)
The special anchor for aircrete with simple hammerset installation.

fischer aircrete GB – the special anchor geometry allows for a form


locking and ideal pressure distribution.
■ Medium loads through optimum pressure distribution in aircrete
■ Simple hammerset installation with a hammer
■ Spiral-shaped outer ribs, cut deeply into the aircrete
■ Ideal for non-plastered surfaces
■ Approval with the fischer safety screw for aircrete masonry and aircrete
ceiling panels (only GB 14)
■ Can be loaded immediately after installation

Designs Type of installation


ned inst
itio

all
Pre-po

ation
Aircrete anchor GB for use with fischer screws or conventional wood screws

Frame fixing SXRL Maximum load-bearing capacity: 1.07 kN (107 kg)


ETA-14/0297
ETAG 020 a, b, c, d
ETA-07/0121
ETAG 020 Part 2, 3, 4, 5

The simple solution for push-through installation in aircrete.


Multiple use in concrete Multiple use in concrete
and masonry for and masonry for
non-structural applications non-structural applications

fischer frame fixing SXRL – the long expansion part offers an even load
distribution in the aircrete and, therefore, a high load-bearing capacity
■ High loads through long, powerful expansion part
■ Pre-assembled set comprising fixing sleeve and safety screw
■ Quick and easy push-through installation
■ Approved for the anchorage of multiple fixings,
e.g. façade sub-structures
■ Can be loaded immediately after installation

Designs Type of installation


ough insta
hr
t

lla
Push-

tion

Frame fixing SXRL-T Frame fixing SXRL-FUS


for timber constructions for metal constructions

Universal fixing UX Maximum load-bearing capacity: 0.40 kN (40 kg)


The universal solution in aircrete.

fischer universal fixing UX – the universal expansion part ideally adapts to


the building material for lightweight loads
■ Good load-bearing capacity with low anchorage depth thanks to the
universal expansion part
■ Quick and easy installation
■ Can be loaded immediately after installation

Designs Type of installation

itio
ned inst ough insta
hr
s

all

lla
Pre-po

Push-
ation

tion

Universal fixing UX with or without edge for the use of screws, hooks and eyes in gvz. and
A4.

XXXXXX-(1)-brochure_aircrete-building-materials-EN.indd 5 15.09.2015 10:54:01


The right fixing
for every application.

fischer fischer fischer


Designation fischer fischer
aircrete anchor aircrete anchor universal fixing
Injection system FIS V frame fixing SXRL
FPX-I GB UX
in undercut drill in cylindrical drill
14 10
hole hole

Illustration

Possible 1.25 kN (125 kg) 1.07 kN (107 kg) 1.20 kN (120 kg) 1.07 kN (107 kg) 0.89 kN (89 kg) 0.90 kN (90 kg) 0.40 kN (40 kg)
max. load

Approval Single point fixing Single point fixing Single point fixing Multiple fixing Multiple fixing Single point fixing No approval

Functionality Undercut (bonded) Bonded Undercut Expansion Expansion Interlocking Expansion

Application Yes, with GB 14 and fischer


Ceiling with No No Yes No No No
safety screw
approval

Application out- Yes, with anchor rod A4 Yes, with anchor rod A4 No Yes, with screw A4 Yes, with screw A4 Yes, with screw A4 Yes, with screw A4
doors

Pre-positioned Yes Yes Yes No No Yes Yes


installation

Push-through No Yes, with annular gap filling No Yes Yes No Yes


installation

Offset Yes Yes Yes No No No No


installation

Type of connec- External and internal thread External and internal thread internal thread Safety screw Safety screw Safety screw Chipboard screw
tion

Usage length Anchor rod length Anchor rod length Anchor rod length up to 290 mm up to 220 mm up to 100 mm screw length
(conditional)
75 mm and 70 mm and 70 mm and Depends on the Depends on the
Anchorage depth 100 mm 70 mm
95 mm 90 mm 90 mm anchor size anchor size

Please note

Loading capacity Note curing time Note curing time Instantly load-bearing Instantly load-bearing Instantly load-bearing Instantly load-bearing Instantly load-bearing

Sophisticated installation,
Sophisticated installation, Simple installation with Simple and quick Simple and quick Simple Simple and
Installation accessories like cone bolt
accessories required setting control installation. installation. hammerset installation quick installation
required

Installation Yes, if the tiles are drilled


Yes Yes Yes Yes No Yes
through tiles out larger

Surface-flush removal with Surface-flush removal with


Removal Surface-flush removal Surface-flush removal Surface-flush removal Surface-flush removal Surface-flush removal
internal thread anchor internal thread anchor

Application examples
- Canopies - Suspended ceilings - Wood façade sub-structures - Pipe fixings - Lighting, lamps
- Awnings - Pipelines - Aluminium façade sub-structures - Shelf fixings - Small shelves
- Cable trays on the wall on the ceiling - Wall cabinets - Trellis - Towel rails
- Cantilever arms - Hand rails - Fixing of wooden beams - Screen mountings - Mirror cabinets
- Wall cabinets - Suspended ceilings
(GB 14)

XXXXXX-(1)-brochure_aircrete-building-materials-EN.indd 6 15.09.2015 10:54:16