PASSENGER ELEVATORS
General and MRL(Machine-Room-Less) Type
PASSENGER ELEVATORS - We reserve the right to change designs and specifications for the product development without prior notice. Printed in Korea
CATALOG CODE : C-VPE-E1208 / 2007. 03 / Revision 12
PASSENGER ELEVATORS 05 2
Passenger Elevators
Hyundai Elevator is very close to the lives of people throughout every moment.
Innovative energy-savings & reduced electric power More flexible architectural design
Control Control
VVVF(Inverter)Microprocessor Control requirements VVVF(Inverter)Microprocessor Control Benefit in north side slanting line limitation and
System System
Speed 30~120m/min Extremely smooth riding comfort & accurate landing Speed 45~105m/min sunshine right regulation
Capacity 6~24 persons/450~1600kg Minimized motor size & minimized noise/vibration Capacity 8~17 persons/550~1150kg Minimized power equipment and power consumption
1Car : Selective Collective (1C 2BC) Enhanced system reliability 1Car : Selective Collective (1C 2BC) Reduction of building costs
Operation Operation
2~4Cars : Group Operation Minimum space requirements 2~4Cars : Group Operation Smoother and superior riding comfort
Environment-friendly products
Applicable up to 32 floors (96m)
PASSENGER ELEVATORS 05 4
Car Design
SE34 SE36
Ceiling Ceiling
CD516B (Indirect lighting)/ CD451B/ Acryl / Acryl Lens /
Convective Air Sterilization System Painted Steel (P022)
Wall Wall
Hairline Etched Stainless Steel (SE739), Hairline Etched Stainless Steel (SE1169)
Galaxy Art (AF-G-246)
Car Doors
Car Doors Hairline Etched Stainless Steel (SE1169)
Galaxy Art(AF-G-246)
Operating Panel
Operating Panel OPP-N240B
OPP-N240B,
OPP-N240W (For the disabled) Indicator
Deluxe Type (PI-D600)
Indicator
Deluxe Type (PI-D600) Handrail
Stainless Steel 1Pipe (1A)
Handrail
Stainless Steel 1Pipe (1A) Entrance Column
Hairline-Finished Stainless Steel
Entrance Column
Hairline-Finished Stainless Steel Flooring
Polyvinyl Tile
Flooring (TN2401C, TN2406C)
Polyvinyl Tile
(TN2211C, TN2401C, TN2412C)
SE35 SE37
Ceiling Ceiling
CD249C/ Acryl / Painted Steel (P021) CD291C/ Acryl / Painted Steel (P021)
Wall Wall
Hairline Etched Stainless Steel (SE1168) Hairline Etched Stainless Steel (SE1177)
Car Doors Car Doors
Hairline Etched Stainless Steel (SE1168) Hairline Etched Stainless Steel (SE1177)
Operating Panel Operating Panel
OPP-N240B, OPP-N241B,
OPP-N240W (For the disabled) OPP-N241W (For the disabled)
Indicator Indicator
Deluxe Type(PI-D600) Deluxe Type(PI-D110)
Handrail Handrail
Stainless Steel 1Pipe (1A) Stainless Steel 1Pipe (1R)
Entrance Column Entrance Column
Hairline-Finished Stainless Steel Hairline-Finished Stainless Steel
Flooring Flooring
Polyvinyl Tile (DTF5311, DTF5906) Polyvinyl Tile ( TN2411C, TN2412C)
Note : Finished product may vary slightly from these prints. Note : Finished product may vary slightly from these prints.
SB20 SB23
Ceiling Ceiling
CD451B / Acryl / Acryl Lens / CD513E(Indirect lighting)/
Painted Steel (P021) Painted Steel / Down Light
Wall Wall
Polyvinyl Sheet (ME03 / ME5011) / Hairline Etched Stainless Steel
Aluminium Di-Casting Trim (SE739/SE798/SE799)
Car Doors Car Doors
Polyvinyl Sheet (ME03) Hairline Etched Stainless Steel (SE739)
Operating Panel Operating Panel
OPP-D240B, OPP-N240,
OPP-N240W (For the disabled) OPP-N240W (For the disabled)
Handrail Indicator
Stainless Steel 1Pipe (1A) Deluxe Type(PI-D600)
Entrance Column Handrail
Hairline-Finished Stainless Steel Stainless Steel 1Pipe (1R)
Flooring Entrance Column
Polyvinyl Tile (86516) Hairline-Finished Stainless Steel
Flooring
Polyvinyl Tile (RN33019)
SB21 SD33
Ceiling Ceiling
CD469B / Acryl / Painted Steel (P017) CD516C (Indirect lighting)/
Convective Air Sterilization System
Wall
Hairline Etched Stainless Steel (SE439) Wall
Dull-Finished Stainless Steel,
Car Doors Galaxy Art (AF-G-247)
Hairline Etched Stainless Steel (SE439)
Car Doors
Operating Panel Galaxy Art (AF-G-247)
OPP-N240,
OPP-N240W (For the disabled) Operating Panel
OPP-D240B,
Indicator OPP-N640 (For the disabled)
Deluxe Type(PI-D600)
Handrail
Handrail Stainless Steel 1Pipe (1A)
Stainless Steel 1Pipe (1R)
Flooring
Entrance Column Polyvinyl Tile ( DTF5311, DTF5907)
Hairline-Finished Stainless Steel
Flooring
Polyvinyl Tile
(TN2202C, TN2203C, TN2211C)
Note : Finished product may vary slightly from these prints. Note : Finished product may vary slightly from these prints.
PI-S100 (LED Segment Type) PI-D600 (Dot Matrix Type) PI-D200 (Dot Matrix Type)
(LED Segment Type : PI-S200)
Hall Buttons
Type of Buttons
1A (Aluminium Bracket /1 Pipe Stainless Polished) 1C (1 Pipe Stainless Hairline, Chrome Bracket)
P011 (4.1R 4.3/12.8) P012 (2.3PB 4.5/9.6) P016 (9.9YR 5.0/3.1) P017 (6.7Y 8.7/2.0)
P019 (5.1Y 7.6/1.1) P020 (Metallic Gold) P021 (Metallic Silver) P022 (Black) 1R (1 Pipe Stainless Polished) *2R (2 Pipe Stainless Polished)
Note : Finished product may vary slightly from these prints. Note : *: optional
Entrance(Etching) Ceiling
CD249C CD251A
(P019) (P022/ Acryl/ Convective Air Sterilization System)
CD469B CD516B
(P019) (Indirect Lighting/ Convective Air Sterilization System)
Note : : Emboss : Intaglio Note : Finished product may vary slightly from these prints.
Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & Reactions (Unit : mm)
Height(MH)
M/C Room
(By others)
A Cinder
Concrete Min.150
R1 Persons kg OP CA CB A B X1 X2 X3 Y MX1 MX2 MX3 MY R1 R2
(By others)
6 450 800 1400 850 1460 1005 1800 3700 5600 1480 2000 4000 6000 3200 3600 2000
window
window
window
window
R2 R1
Gallerywindow
others)
others)
others)
others)
(Byothers)
8 550 800 1400 1030 1460 1185 1800 3700 5600 1660 2000 4000 6000 3400 4050 2250
(By others)
Gallery
Vent Fan
Gallery
Gallery
Gallery
(By
(By
(By
(By
Overhead (OH)
Y
CB
1400 1100 1460 1255 1800 3700 5600 1730 2000 4000 6000 3500
B
OP 45 10 700 800 1400 1250 1460 1405 1800 3700 5600 1880 2000 4000 6000 3600 4200 2700
R2
Control 11 750 800 1400 1350 1460 1505 1800 3700 5600 2000 2000 4000 6000 3700 4550 2800
Panel
1600 1350 1660 1505 2050 4200 6350 2000 2300 4400 6800 3750
13 900 900
Travel (TR)
Access Door(By others)
Min. 900(W) 2000(H) 1600 1500 1660 1655 2050 4200 6350 2150 2300 4400 6800 3850
15 1000 900 5450 4300
1600 1550 1660 1705 2050 4200 6350 2200 2300 4400 6800 3900
90 1000 1800 1500 1900 1670 2350 4800 7250 2280 2600 4900 7500 3900
17 1150 6600 5100
2100
40 with ventilating fan and /or air conditioner(if necessary)
and humidity below 90%. 1800 1700 1900 1870 2350 4800 7250 2480 2600 4900 7500 4200
1000
105 1800 1730 1900 1900 2350 4800 7250 2510 2600 4900 7500 4300
Pit Depth (PP)
MX2 2000 1800 2100 1970 2550 5200 7850 2580 2900 5400 8300 4400
X2 MX3 24 1600 1100 8500 6800
X3 2150 1600 2250 1770 2700 5500 8300 2380 3000 5650 8700 4200
X1
X2
A 2150 1670 2250 1840 2700 5500 8300 2450 3000 5650 8700 4300
X1
R1 R1
Min. 100
A
R1 R1 R1 Notes : 1. colored dimensions shall be applied for Malaysia & Singapore market.
others)
others)
others)
others)
Fan(Byothers)
Gallery window(By others)
Gallery window(By others)
Beam (By others) 2. Above hoistway dimensions are based on 15-storied buildings. For application to over 16-storied buildings,
Vent Fan(By others)
the hoistway dimensions shall be at least 5% larger considering the sloping of the hoistways.
Fan(By
Fan(By
Fan(By
VentFan(By
Beam
(By others) 3. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
Vent
Vent
Vent
4. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
B Vent
CB
Y
B
CA CA
OP OP OP
MY
Gallery window(By others)
Gallery window(By others)
OP OP R2 R2 R2
MY
(Unit : mm)
Vent Fan(By others)
R2 R2
Speed Overhead Pit M/C Room Height
Control Control Control Control Control
Panel Panel Panel Panel Panel (m/min) (OH) (PP) (MH)
Distribution Board Distribution Board 45 4400 1200 2200
(By others) (By others)
60 4600 1500 2200
90 4800 1800 2400
Machine Room
Machine Room Access Door(By others) 105 5000 2100 2400
Access Door(By others) Min. 900(W) 2000(H)
Min. 900(W) 2000(H)
120 5000 2100 2600
SPACE SAVER(Permanent Magnet Synchronous Motor) Only for Floor with Control Panel of the Machine-Room-Less Elevators
Plan of Hoistway Section of Hoistway
X Lighting(By others) Lighting(By others)
Hook(By others)
A
Overhead (OH)
30
CB
Y
B
700
Steel Bar for 150
Fixing Jambs
9 6EA (By others)
OP
Hall Button
Jamb Height(JH)
500
Indicator
700
Control Panel Control
Control
Control
Control
Control
Control
Control
Panel
Panel
Panel
Panel
Panel
Panel
530 OP
Travel (TR)
1000
Power Distribution CP Clear Opening (OP) 30 Concrete Opening
Board(By others)
530
700
Clear Opening Clear Opening
Receptacle Finished +CP+100 +100
Floor Level 2 2
(Unit : mm) (By others) (By others)
Notes : 1. Above dimensions are applied in Ladder
Speed Overhead Pit case car height is 2500mm. (By others)
(m/min) (OH) (PP) (Car internal height is 2300mm.)
8~15Persons : 1500 2. The dimensions in ( ) are applied in case car
3800 Lighting(By others)
cL OF CAR
Standard Dimensions (Unit : mm)
Transom Panel
700
90 8 550 800 1300 1100 1360 1255 2050 1700 5.1 Steel Bar for
105 5.9 Fixing Jambs
Jamb Height(JH)
300
60 4.3
700
90 10 700 800 1300 1300 1360 1455 2050 1800 6.5
105 7.5
60 4.6
90 11 750 800 1300 1400 1360 1555 2050 1850 6.9
105 8.1 CP Clear Opening (OP) 30
1000
60 5.6 530 Concrete Opening
700
1600 1300 1660 1455 2300 1800 Finished Clear Opening Clear Opening
90 13 900 900 8.3 Floor Level +CP+100 +100
1500 1400 1560 1555 2200 1850 2 2
105 9.7 (By others)
60 6.2
1900
90 15 1000 900 1600 1400 1660 1555 2300 9.2
(2100)
105 10.8
60 7.1
CP210 Type (Optional) CP210 Type (Optional)
90 17 1150 1000 1800 1400 1900 1570 2600 2100 10.6
105 12.4
Notes : 1. The dimensions in ( ) are applied in case stone-finished flooring.
2.When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
3.The capacity in persons is calculated at 68kg/person. (EN81 75kg/person)
Entrance Structural Opening of Entrance In case of Boxless Type Plan of Entrance Section Entrance
Buttons and Fire man’s witch
30
90
Wiring Inlet : 50
Jamb Width
50
(By others)
Thickness
150
700
Wall
100
700
Wall Finish
Entrance Height (EH) : 2100
Steel
Steel Bar
Bar for
for
Thickness
Steel
SteelBar
Steel Barfor
Bar for
for 30 30
HB With HPI Concrete Opening : 2200 Fixing
Fixing
Fixing
FixingJamb
Fixing Jamb
Jamb
Jamb
Jamb
99 6
6 EA
EA
EA
(By
(By
EA
9999 6666 (By others)
others)
(Byothers)
others)
500
EA
EA
EAEA
EA
EA
EA
(By
(By others)
others) (150)
700
70 Clear Opening (OP) 70 HB With HPI
700
1700
Steel
SteelBar
Steel
Steel
Steel Bar
Bar
Bar for
Barfor
for
for
for 80
1050
Clear
Clear
1000
Concrete (By
(By others)
others)
30 Opening
Opening
Opening
Opening
Opening (OP)
(OP)
Opening(OP)
(OP)
(OP)
(OP)
700
Opening
700
Jamb Width
OP+140
Finished Floor Level
(By others)
90
Concrete Opening Finished Floor Level
JP050 Type (Basic) (By others)
Jamb Width
Thickness
Wall
Wall Finish
Thickness
50
200
500
30 (180)
Indicator
30
Emergency Call
Switch 150 90
700
applied) Fixing
Fixing
Fixing
FixingJamb
Fixing
Fixing Jamb
Jamb
Jamb
Jamb
Jamb
Jamb Height (JH)
99999 66666EAEAEA(By
(By others)
EA
EA
EA
EA
EA EA
EA (Byothers)
(By
(By others)
others)
others) Building Structure
HB (By other Contractors)
700
300
JP050 Type
1650
Clear
Clear
Clear
Clear
Clear
1000
30 Opening
Opening
Opening
Opening (OP)
Opening(OP)
(OP)
(OP)
(OP) Concrete
700
Opening
OP+300
50
50
Finished Floor Level
(By others)
50
Ceiling Line
Upper
JP100 Type (Optional)
100
frame
10 10
Finished Ceiling Level
50
30
(By others)
700
floor is applied)
Entrance Height (EH) : 2100
floor is applied)
Entrance Height (EH) : 2100
50
50
300
HB HB
50
700
1650
90 90
Clear
Clear Clear
Clear 90
1000
Clear
Clear
Clear Clear
Clear
Clear Concrete
30 Opening
Opening
Opening
Opening (OP)
Opening(OP)
(OP)
(OP)
(OP) 30 Opening
Opening
Opening (OP)
Opening(OP)
Opening (OP)
(OP)
(OP) Opening
700
OP+300
2) Duplex selective When a fire breaks out, all cars activated by the switch or fire detector are immediately
2 units of elevator provide the effective service for the common hall calls 15) Fire emergency service
collective called to a specified rescue floor for the passenger s safety.
Evaluates the number of people on the car and compares that value to the number of the
When a car is 80% loaded, it will automatically bypass all hall calls as the bypass load
3) Automatic bypass car calls registered. If the number of car calls exceeds the number of people in the car by
weighing device is activated. 16) Anti-nuisance
the load sensor, the car call exceeding the number of passengers will be cancelled after
service nearest all only.
4) Chime bell It provides an audible indication in the car that an elevator is about to arrive.
A voice synthesizer with microprocessor makes announcements to inform passengers of
17) Voice synthesizer
various conditions, including landing floor and operation direction, etc.
Digital(Segment) type
5) Signal fixtures Dot matrix type(moving direction)
Hall lantern
18) Emergency power During normal power failure, elevator service continues with building s
operation emergency power source.
Contact with a passenger or inanimate object causes the doors to stop and
6) Single-side safety
reopen automatically.
edge of door The elevator doesn t start if the door is completely not closed. When the fireman s switch located at the main floor lobby and operating panel on the car
19) Fireman s emergency
is activated during a fire or other emergency, a designated car can be called back to a
service specified floor for fire fighting service.
7) Ventilation fan Car ventilation is smooth with ventilation fan built-in the ceiling.
The following works are not included in the elevator contract, and shall be done by other contractors VVVF 50 / 60Hz, 380V
in accordance with the Hyundai Elevator’s drawings and the applicable codes and regulations.
C.B. Rated Transformer C.B. Rated Transformer
The reference rules shown are from ANSI A17.1 Code. (The followings are based on the general type. Persons Speed Motor Current Capacity
Power Feeder Earth Wire
Persons Speed Motor Current Capacity
Power Feeder Earth Wire
(mm2) (mm2) (mm2) (mm2)
Consult Hyundai for the Machine-Room-Less elevators.) (kg) (m/min) (kW) (A) (KVA) (kg) (m/min) (kW) (A) (KVA)
1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars
60 5.5 (2.8) 20 (10) 30 (20) 4 (3) 7 (5) 4 (4) 6 (4) 6 (6) 10 (6) 60 11 (5.6) 30 (20) 50 (30) 8 (6) 14 (10) 6 (4) 10 (6) 6 (6) 10 (6)
6 90 7.5 (4.1) 20 (20) 30 (40) 6 (4) 10 (8) 4 (4) 6 (10) 6 (6) 10 (6) 13 90 15 (8.3) 40 (30) 60 (50) 12 (9) 21 (16) 10 (6) 16 (16) 6 (6) 10 (10)
Building Work Electrical Work (450) 105 7.5 (4.8) 20 (20) 40 (40) 7 (5) 12 (9) 4 (4) 10 (10) 6 (6) 10 (6)
(900) 105 15 (9.7) 40 (30) 75 (50) 14 (10) 24 (18) 10 (6) 25 (16) 10 (6) 16 (10)
120 11 30 50 8 14 6 16 6 10 120 18.5 (11.1) 50 (30) 100 (60) 15 (12) 28 (21) 16 (6) 25 (16) 10 (6) 16 (10)
Hoistway Hoistway 60 5.5 (3.4) 20 (10) 30 (20) 5 (4) 9 (6) 4 (4) 6 (4) 6 (6) 10 (6) 60 11 (6.2) 30 (20) 50 (40) 9 (6) 15 (12) 6 (4) 16 (10) 6 (6) 10 (10)
8 90 7.5 (5.1) 20 (20) 30 (40) 7 (5) 13 (10) 4 (4) 6 (10) 6 (6) 10 (6) 15 90 15 (9.2) 40 (30) 75 (50) 13 (10) 23 (17) 10 (6) 25 (16) 10 (6) 16 (10)
1. Clear, plumb hoistway with fire resistant hatch walls as required by the gover- 1. Light outlet for each elevator, in center of hoistway (or in machine room)as indi-
(550) 105 11 (5.9) 30 (20) 50 (40) 8 (6) 15 (11) 6 (4) 16 (10) 6 (6) 10 (6) (1000) 105 15 (10.8) 40 (30) 75 (60) 15 (11) 27 (20) 10 (6) 25 (16) 10 (6) 16 (10)
ning code. (Rule 100.1a) cated by Hyundai Elevator Company.
120 11 30 50 9 17 6 16 6 10 120 18.5 (12.3) 50 (40) 100 (75) 17 (13) 31 (23) 16 (10) 25 (25) 10 (10) 16 (16)
2. 75 bevel guards on all projections, recesses or setbacks over 50mm except on 2. Convenience outlet and light fixture in pit with switch located adjacent to the
60 5.5 (3.7) 20 (20) 30 (30) 5 (4) 9(7) 4 (4) 6 (6) 6 (6) 10 (6) 60 11 (7.1) 30 (20) 50 (40) 10 (7) 18 (13) 6 (4) 16 (10) 6 (6) 10 (10)
side used for loading or unloading. (Rule 100.6) access door. (Rule 106.1e)
9 90 11 (5.6) 30 (20) 50 (40) 8 (6) 14 (10) 6 (4) 16 (10) 6 (6) 10 (10) 17 90 15 (10.6) 40 (30) 75 (60) 15 (11) 27 (20) 10 (6) 25 (16) 10 (6) 16 (10)
3. Venting of the hoistway as required by the governing code or authority. 3. Wiring and piping work of emergency bell, interphone, etc. Outside the hoistway
(600) 105 11 (6.5) 30 (20) 50 (40) 9 (7) 16 (12) 6 (4) 16 (10) 6 (6) 10 (10) (1150) 105 18.5 (12.4) 50 (30) 100 (60) 17 (13) 31 (23) 16 (6) 25 (16) 10 (10) 16 (16)
(Rule 100.4) and the machine room.
120 11 30 60 10 19 6 16 6 10 120 22 (14.1) 60 (40) 100 (75) 20 (15) 36 (27) 16 (10) 25 (25) 10 (10) 16 (16)
4. Supports for rail brackets at each floor, roof, and machine room. (Rule 200.9)
Maximum allowable vertical spacing of rail supports, without backing. (Rule 60 7.5 (4.2) 20 (20) 40 (30) 6 (5) 11 (8) 4 (4) 10 (6) 6 (6) 10 (6) 60 15 30 60 12 21 6 16 6 10
200.4 and 301.1) Machine Room 10 90 11 (6.3) 30 (20) 50 (40) 9 (7) 16 (12) 6 (4) 16 (10) 6 (6) 10 (6) 20 90 18.5 50 100 17 31 16 25 10 16
(700) 105 11 (7.3) 30 (20) 60 (40) 11 (8) 19 (14) 6 (4) 16 (10) 6 (6) 10 (6) (1350) 105 22 50 100 20 37 16 25 10 16
Divider beams 100mm between hoistway at each floor and roof, for guide rail 4. Lighting, convenience outlets, ventilation, heating of machine room, and machinery
bracket supports.(Rule 200.4, 200.9 and 301.1) space. (Rule 101.5) 120 15 40 75 12 22 10 25 10 16 120 30 75 125 23 42 16 35 16 25
5. Recesses, supports and patching as required to accommodate hall button 5. Temperature should be maintained below 40 C with ventilating fan and/or air 60 7.5 (4.6) 20 (20) 40 (30) 6 (5) 12 (9) 4 (4) 10 (6) 6 (6) 10 (6) 60 15 40 75 14 25 10 22 10 16
boxes, signal fixtures, etc. conditioner, if necessary, and humidity below 90%. 11 90 11 (6.9) 30 (20) 50 (40) 10 (7) 17 (13) 6 (4) 16 (10) 6 (6) 10 (10) 24 90 22 50 100 21 37 16 25 16 25
6. All barricades either outside elevator hoistways or between elevators inside 6. A fused disconnect switch or circuit breaker for each elevator and light switch (750) 105 11 (8.1) 30 (30) 60 (50) 11 (8) 20 (15) 6 (6) 16 (16) 6 (6) 10 (10) (1600) 105 22 60 125 24 43 16 35 16 25
hoistways as required. located per the governing code and where practicable located adjacent to the 120 15 (9.2) 40 (30) 75 (50) 13 (10) 23 (17) 10 (6) 25 (16) 10 (6) 16 (10) 120 30 75 125 28 50 25 35 16 25
7. Dry pit reinforced to sustain normal vertical forces from rails and buffers. door of the machine room. (Rule 210.5 and 306.7)
(Rule 106.1b and 109) 7. Feeder and branch wiring to the controller, including mainline switch and con-
Consult Hyundai Elevator Company for rail forces and buffer impacts. Where venience outlets. VVVF 50 / 60Hz, 220V
there is space below the pit floor which can be occupied, consult Hyundai 8. Suitable power feeder and branch wiring circuits as required for elevators with
Elevator Company for special requirements. (Rule 300.4) power operated doors, including disconnect switch or circuit breaker. C.B. Rated Transformer Power Earth Starting C.B. Rated Transformer Power Earth Starting
Persons Speed Motor Current Capacity Feeder Wire Power Persons Speed Motor Current Capacity Feeder Wire Power
8. Where access to the pit is by means of the lowest hoistway entrance, vertical (kg) (m/min) (kW) (A) (KVA) (mm ) 2
(mm )
2
(KVA) (kg) (m/min) (kW) (A) (KVA) (mm ) 2
(mm ) 2
(KVA)
iron ladder extending 1060mm minimum above sill of access door. (Rule 106.1d) 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars 1Car 2Cars
9. Entrance walls and finished floor are not to be constructed until after door Emergency Provisions
60 5.5 (2.8) 30 (20) 50 (40) 4.3 (3.3) 8 (6) 3.5 (3.5) 8 (5.5) 3.5 (3.5) 5.5 (5.5) 7.7 (5.9) 13.9 (10.6) 60 11 (6.2) 40 (30) 75 (60) 9.6 (7.2) 17 (13) 8 (5.5) 22 (14) 5.5 (3.5) 8 (8) 17.2 (13) 31 (23.4)
frames and sills are in place. 9. Elevator fireman s and other emergency services wiring and interconnections
6 90 7.5 (4.2) 30 (30) 60 (60) 6.4 (4.9) 12 (9) 5.5 (5.5) 14 (14) 3.5 (3.5) 8 (8) 11.6 (8.8) 20.9 (15.9) 15 90 15 (9.2) 60 (50) 125(100) 14.3 (10.8) 26 (19) 14 (8) 38 (38) 8 (5.5) 22 (14) 25.8 (19.5) 46.4 (35)
Door frames are to be anchored to walls and properly grouted in place to main- to automatic sprinkler systems or heat and smoke sensing devices furnished by
(450) 105 7.5 (4.9) 40 (30) 75 (60) 7.5 (5.7) 14 (10) 5.5 (5.5) 14 (14) 5.5 (3.5) 8 (8) 13.5 (10.3) 24.4 (18.5)
(1000) 105 15 (10.8) 75 (50) 125(100) 16.7 (12.6) 30 (23) 14 (14) 50 (38) 8 (5.5) 22 (14) 30.1 (22.7) 54.2 (40.8)
tain legal fire rating. others and installed to terminal points on the elevator controllers.
120 11 40 75 8.6 15 8 22 5.5 8 15.5 27.9 120 18.5 (12.3) 75 (60) 150(125) 19.1 (14.4) 34 (26) 22 (14) 60 (38) 8 (8) 22 (22) 34.4 (25.9) 61.9 (46.6)
10. Sill supports 64mm minimum floor recesses full hoistway width for entrance 10. When emergency power operation of elevators is required, the electrical con-
60 5.5 (3.4) 30 (20) 50 (40) 5.3 (4) 9 (7) 3.5 (3.5) 14 (5.5) 3.5 (3.5) 5.5 (5.5) 9.5 (7.2) 17.0 (13) 60 11 (7.1) 50 (40) 100 (75) 11.0 (8.3) 20 (15) 8 (5.5) 38 (22) 5.5 (5.5) 14 (8) 19.8 (14.9) 35.6 (26.9)
sills, with grouting after sills are set in place. tractor should coordinate with Hyundai Elevator Company or local distributor
8 90 7.5 (5.1) 40 (30) 75 (60) 7.9 (6) 14 (11) 5.5 (5.5) 22 (14) 5.5 (3.5) 8 (8) 14.2 (10.7) 25.5 (19.3) 17 90 15 (10.6) 75 (50) 125(100) 16.5 (12.4) 30 (22) 14 (14) 50 (38) 8 (5.5) 22 (14) 29.7 (22.4) 53.4 (40.2)
11. For application as indoor observation elevator, a minimum 3.6m high glass for operation requirements.
(550) 105 11 (5.9) 40 (30) 75 (60) 9.2 (7) 17 (13) 8 (5.5) 22 (14) 5.5 (3.5) 8 (8) 16.6 (12.5) 29.8 (22.5) (1150) 105 18.5 (12.4) 75 (60) 150(125) 19.2 (14.5) 35 (26) 22 (14) 60 (38) 8 (8) 22 (22) 34.6 (26.1) 62.3 (46.9)
enclosure above bottom landing is recommended for safety. 11. Elevator fireman s and other emergency service requirements may differ from
each country. Consult Hyundai Elevator Company or local distributor for other 120 11 40 100 10.5 19 8 22 5.5 14 18.9 34.1 120 22 (14.1) 100 (70) 175(150) 22.0 (16.5) 40 (30) 38 (22) 80 (50) 14 (8) 38 (22) 39.6 (29.8) 71.2 (53.6)
For application as outdoor observation elevator, full height glass enclosure is
local requirements. 60 5.5 (3.7) 30 (20) 60 (40) 5.7 (4.4) 10 (8) 3.5 (3.5) 14 (8) 3.5 (3.5) 8 (5.5) 10.3 (7.8) 18.6 (14.1) 60 15 (8.3) 50 (40) 100 (75) 12.9 (9.7) 23 (18) 14 (8) 38 (22) 5.5 (5.5) 14 (8) 23.2 (17.5) 41.8 (31.5)
required.
12. When provisions for earthquake protection are required, consult Hyundai 9 90 11 (5.6) 40 (30) 75 (60) 8.6 (6.5) 15 (12) 8 (5.5) 22 (14) 5.5 (3.5) 8 (8) 15.5 (11.7) 27.9 (21.1) 20 90 18.5 (12.5) 75 (60) 150(125) 19.3 (14.6) 35 (26) 22 (14) 60 (38) 8 (8) 22 (22) 34.8 (26.2) 62.7 (47.2)
Elevator Company for special requirements. (600) 105 11 (6.5) 40 (30) 100 (60) 10.0 (7.6) 18 (14) 8 (5.5) 22 (14) 5.5 (3.5) 14 (8) 18.1 (13.7) 32.5 (24.6) (1350) 105 22 (14.5) 100 (60) 200(125) 22.6 (17) 41 (31) 38 (14) 80 (38) 14 (8) 38 (22) 40.6 (30.6) 73.1 (55)
Machine Room 120 11 50 100 11.5 21 8 38 5.5 14 20.6 37.2 120 30 (16.6) 100 (70) 200(150) 25.8 (19.4) 46 (35) 38 (22) 80 (50) 14 (8) 38 (22) 46.4 (34.9) 83.6 (62.9)
12. Enclosed and protected machine room. (Rule 101.1) 60 7.5 (4.3) 30 (20) 60 (40) 6.7 (5.1) 12 (9) 5.5 (3.5) 14 (8) 3.5 (3.5) 8 (5.5) 12 (9.1) 21.7 (16.4) 60 15 (9.9) 60 (50) 125(100) 15.3 (11.5) 28 (21) 14 (8) 50 (38) 8 (5.5) 22 (14) 27.5 (20.7) 49.5 (37.3)
13. Access to the machine room and machinery space as required by the governing 10 90 11 (6.5) 40 (30) 100 (60) 10.0 (7.6) 18 (14) 8 (5.5) 22 (14) 5.5 (3.5) 14 (8) 18.1 (13.7) 32.5 (24.6) 24 90 22 (14.8) 100 (70) 200(125) 22.9 (17.3) 41 (31) 38 (22) 80 (50) 14 (8) 38 (22) 41.3 (31.1) 74.3 (55.9)
code or authority. (Rule 101.3) Heat Emission of Machine Room (700) 105 11 (7.6) 50 (40) 100 (75) 11.7 (8.8) 21 (16) 14 (5.5) 38 (22) 5.5 (5.5) 14 (8) 21.1 (15.9) 37.9 (28.6) (1600) 105 22 (17.2) 100 (80) 200(150) 26.8 (20.1) 48 (36) 38 (22) 100 (60) 14 (14) 38 (22) 48.2 (36.2) 86.7 (65.2)
14. Reinforced concrete machine room floor slab or grating, as specified, which 120 15 60 125 13.4 24 14 38 8 22 24.1 43.3 120 30 (19.7) 125 (80) 225(175) 30.6 (23) 55 (41) 38 (22) 100 (80) 22 (14) 38 (38) 55 (41.4 ) 99.1 (74.5)
must not be placed over the hoistway until elevator machinery is set in position. Q(Kcal/H) = W V F N 60 7.5 (4.6) 30 (30) 60 (50) 7.2 (5.4) 13 (10) 5.5 (3.5) 14 (8) 3.5 (3.5) 8 (5.5) 12.9 (9.8) 23.2 (17.6) Notes : 1. Above power feeder sizes are for the length of electric wire up to 50m from elevator
(Rule 100.3 for Traction Elevator) 11 90 11 (6.9) 50 (40) 100 (75) 10.7 (8.1) 19 (15) 8 (5.5) 38 (14) 5.5 (5.5) 14 (8) 19.3 (14.6) 34.8 (26.3) machine room to transformer.
W: Capacity (kg) N: Number of cars For the length being 50m or more, the following formular should be applied:
15. Hoisting beams, trap doors and other means of access to machine room for (750) 105 11 (8.1) 50 (40) 100 (75) 12.5 (9.5) 23 (17) 14 (8) 38 (22) 5.5 (5.5) 14 (8) 22.6 (17) 40.6 (30.7)
V: Speed (m/min) 2. Above power feeder sizes are for copper wires inside electrometallic tubings.
maintenance and equipment removal purposes. (Rule 101.3d) F: Factor (1/40: VVVF) 120 15 (9.2) 60 (40) 125(100) 14.3 (10.8) 26 (19) 14 (8) 38 (22) 8 (5.5) 22 (14) 25.8 (19.5) 46.4 (35) Power feeder length(m)
Power feeder sizes(mm2) = Size in the above(mm2)
16. Cable guards in the machine room or secondary level. (Rule 104.1) 60 11 (5.6) 40 (30) 75 (50) 8.6 (6.5) 15 (12) 8 (3.5) 22 (14) 5.5 (3.5) 8 (5.5) 15.5 (11.7) 27.9 (21.1) 50
3. For power requirement of 3 cars or more, consult Hyundai.
17. Supports for machine and sheave beams and reactions including wall pockets 13 90 15 (8.3) 50 (40) 100 (75) 12.9 (9.7) 23 (18) 14 (8) 38 (22) 5.5 (5.5) 14 (8) 23.2 (17.5) 41.8 (31.5)
4. Machine room temperature should be maintained below 40 with ventilating fan and
and patching after beams are set in place. (Rule 105.1 to 105.5) (900) 105 15 (9.7) 60 (50) 125(100) 15.0 (11.3) 27 (20) 14 (8) 50 (38) 8 (5.5) 22 (14) 27.1 (20.4) 48.8 (36.8) air conditioner, and humidity below 90%.
120 18.5 (11.1) 75 (50) 150(100) 17.2 (13) 31 (23) 22 (14) 50 (38) 8 (5.5) 22 (14) 31 (23.3) 55.7 (42) 5. Data shown in ( ) is applied to the Machine-Room-Less elevators. (Gearless type)