Fupact: Catalog 2020
Fupact: Catalog 2020
Fupact: Catalog 2020
Catalog 2020
Fusegear range from 32 to 1250 A
schneider-electric.com
se.com
Green Premium
TM
Discover what we
mean by green
Check your products!
*PEP: Product Environmental Profile (i.e. Environmental Product Declaration)
www.se.com FuPacT | 1
An alternative approach
to electrical
protection
2 | FuPacT www.se.com
Fuse devices are designed to perform three functions for electrical protection:
• Switch function for circuit on-load control
• Fuse function against short-circuits and overloads
• Isolation from the power circuit.
Slidable windows
• Enabling independent testing of individual fuse-links
www.se.com FuPacT | 5
Measuring device
• Energy consumption control is feasible by
the easy installation of a measuring device
Easy to hook
• Turnable contact hooks available for FuPacT ISFL
160 A 3-pole (60 mm busbars)
• Fast mounting with reduced manual operations
• Adapted to all busbar systems: 60/100/185 mm,
present in main switchboards
Fuse monitor
• Precise location and fast correction of
short-circuit and overload faults
Improve your power distribution with Power and control your industrial
FuPacT GS motors with FuPacT GS
• Distribution switchboards. • Motor starters: DOL, Star-Delta, softstarters.
• Disconnection, isolation, locking and primary control • Variable speed starters with frequency converters.
of incoming circuits. • Machine types: HVAC units, industrial cranes, hoists.
• Categories AC21/AC22 for electrical distribution, • Industries: paper, steel, ports, automotive, power, mining,
AC23 for motor feeders. rail, oil & gas.
www.se.com FuPacT | 7
Fuse-link offer
Schneider Electric provides a fuse-link offer with NH fuses to a complete solution for our
customers.
• Fuse-links type aM
Protection of equipment with current peaks like motor
applications.
• Fuse-links type gG
Protection of circuits without significant electrical
distribution current peaks.
8 | FuPacT www.se.com
Functional installation
in Prisma product range
Easy implementation
FuPacT fusegear can be installed on mounting plates or mounted directly on
the busbar from 60 to 185 mm.
Easy installation with special components for each type of mounting and clear
instructions in accordance with standard working practices.
FuPacT ISFT
A
FuPacT ISFL
B
FuPacT GS
C
Catalog numbers
D
> Complementary
technical information > Prisma P > Prisma G
1
Presentation www.se.com
bb isolation with positive contact indication when the switch is in the open position
(OFF). The fuse-link is completely isolated from the power circuit (double breaking
technology).
bb protection against short-circuits and overloads on distribution circuits.
This function is provided by industrial fuse-links (NFC, DIN, BS) used in
conjunction with the switch-disconnector fuse device.
bb safety or emergency stop (red/yellow rotary handle option).
ISFT with turnable hooks
DB120076.eps
(switch-disconnector).
bb protection against overloads and short-circuits (fuse).
bb the combination can implement Compact INS or INV switch-disconnectors
from 40 to 2500 A.
DB120078.eps
INS switch-disconnectors
Control
DB120079.eps
PB117726_L9.eps
Protection
Fuse-link
2
www.se.com
Presentation
General description of FuPacT fusegear
DB424788.ai
380/415V 160 160 -
bb IEC 60947-3: switches, disconnectors 500V 160 160 -
690V 160 - -
bb IEC 60947-5.1 and following: control-circuit devices and switching elements; DC21B DC22B
220V / nb pole 160/3 160/3
automatic control components. 440V / nb pole 125/3 -
-
-
These standards and recommendations are applied in most countries. Max(A) 160 Max(W) 12
FuPacT fusegear and auxiliaries comply with International standards (IEC 60947-1 HD 60269-2 DIN 43620-1
and IEC 60947-3). ISFT label
FuPacT GS and FuPacT ISFp are designed for use with industrial fuse-links
complying with the following standards:
bb IEC 60269
bb BS 88 (only for FuPacT GS)
bb DIN 43620 / VDE 0636.
FuPacT GS switch-disconnector fuses are suitable for the control of
machine-tools:
PB115835.eps
bb they comply with the requirements of the new machine directive IEC 60204
(EN 60204)
bb they comply with French standard NF C 79-130 and the recommendations issued
by the CNOMO organisation.
Climatic environment
FuPacT fusegear meets climatic requirements as defined in the following standards:
bb IEC 60068-2-30: damp-heat tests under off-load conditions, 95 % relative humidity
at 55 °C (hot and humid climate conditions) Fusegear with
bb IEC 60068-2-52: salt-mist tests, KB severity 2 tests terminal shields
bb IEC 60068-2-56: damp-heat tests under on-load conditions for 48 hours, IP20 and IK07
environment category C2 following Schneider quality specifications.
The fusegear can therefore be used in all climates.
Degree of pollution
FuPacT fusegear is certified for operation in pollution-degree 3 environments as
defined by IEC 60947 standard applying to industrial environments.
Ambient temperature
The FuPacT range can be used between -20 °C and +70 °C. Above 40 °C, you will
have to take account of the derating indicated in the documentation.
The devices must be commissioned at the ambient temperature indicated above.
The FuPacT range must be stored in its original packaging at a temperature between
-50 °C and +85 °C.
PB120396.eps
Degree of protection
For FuPacT fusegear with terminal shield, the degree of protection against direct
contact complies with standard IEC 60529 (IP index of protection) and IEC 62262:
bb with direct rotary handle: IP20/IK07
bb with extended rotary handle (FuPacT GS): IP65/IK10 Fusegear in an enclosure or cabinet (extended
bb with extended rotary handle and padlocks: IP65/IK08. handle);
GSp only.
Positive contact indication
IP65 and IK10.
IEC 60947-3 standard defines isolation with positive contact indication as follows:
bb the isolation position corresponds to the O (OFF) position
bb the operating handle cannot indicate the OFF position unless the main contacts
are not totally opened
bb locking in the OFF position is not possible unless the main contacts are actually
open.
PB120397.eps
GSp switch-disconnector fuses are suitable for isolation with positive contact
indication.
Installation of an extended handle on GSp fusegear does not alter the suitability for
isolation.
3
www.se.com
A
D
ISFT100N ISFT100
ISFT160 ISFT250
ISFT400
ISFT630
www.se.com
FuPacT ISFT
ISFT installation
FuPacT ISFT100N to ISFT630 ....................................................... A-14
Fuse monitor
FuPacT ISFT160 to ISFT630.......................................................... A-22
Insulation
FuPacT ISFT100N to ISFT630........................................................ A-24
Other chapters
Presentation....................................................................................................2
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
A-1
www.se.com
FuPacT ISFT
Installation recommendations
Possible installation positions and mounting
FuPacT ISFT100N to ISFT630........................................................ A-30
Other chapters
Presentation....................................................................................................2
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
www.se.com
FuPacT ISFT
FuPacT ISFT100 A
Dimensions..................................................................................... A-35
Mounting and front panel cut-outs................................................. A-36
Connection and accessories.......................................................... A-37
FuPacT ISFT160
Dimensions..................................................................................... A-39
Mounting and front panel cut-outs................................................. A-40
Connection and accessories.......................................................... A-41
Wiring diagrams
FuPacT ISFT........................................................................... A-47
Other chapters
Presentation....................................................................................................2
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
A-3
Functions and characteristics www.se.com
Fuse switch-disconnectors
Number of poles / type of fuse-link IEC 60269-2-1 Section 1
Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3
PB115837.eps
A
Rated insulation voltage (V) Ui AC 50/60 Hz / DC
Rated impulse withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
DC
Rated operational voltage AC20 and DC20 (V) Ue
Rated operational current (A) Ie AC 50/60 Hz
220/240 V
ISFT100N 380/415 V
440/480 V [1]
500 V
660/690 V
DC/poles in series
220 V /no. of poles
PB115838.eps
Pollution degree
Control
Direct front rotary handle (operator-dependent opening and closing)
Locking Padlocks
Lead seal
Indication auxiliaries
Auxiliary contacts
ISFT160
Fuse monitor
Installation and connection accessories
Possible mounting positions Horizontal
Vertical
PB115835.eps
A-4
www.se.com
Functions and characteristics
Fuse switch-disconnector selection
FuPacT ISFT100N to ISFT630
A
1000 690 1000 1000 1000 1000
6 6 8 8 8 8
690 690 690 690 690 690
440 440 440 440 440 440
800 800 800 800 800 800
AC21B AC22B AC21B AC22B AC21B AC22B AC21B AC22B AC21B AC22B AC21B AC22B
100 100 100 100 160 160 [3] 250 250 [4] 400 400 [5] 630 630 [6]
100 100 100 100 160 160 [3] 250 250 [4] 400 400 [5] 630 630 [6]
100 100 100 - 160 160 250 250 400 400 630 630
100 100 100 - 160 160 250 250 400 400 630 630
100 - 100 - 160 - 250 250 400 400 630 630
DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B
100/3 100/3 100/3 - 160/3 160/3 250/3 250/3 400/3 400/3 630/3 630/3
100/3 100/3 100/3 - 125/3 - 250/3 - 400/3 - 630/3 -
80/5.1kA peak/100 A 80/ 3 kA /100 A 80/ 5 kA peak /160 A 80/ 15 kA peak /250 A 80/ 22.1 kA peak /400A 80/ 25.2 kA peak /630 A
80/5.1kA peak/100 A 50/ 3 kA /100 A 80/ 5 kA peak /160 A 80/ 15 kA peak /250 A 80/ 22.1 kA peak /400A 80/ 25.2 kA peak /630 A
80/5.1kA peak/100 A 50/ 3 kA / 100 A 80/ 5 kA peak /160 A 80/ 15 kA peak /250 A 50/ 22.1 kA peak /400A 80/ 25.2 kA peak /630 A
2000 2000 1600 1600 1000 1000
300 300 200 200 200 200
300 - 200 200 200 200
300 - 200 200 200 200
- 300 - - - -
- - - 200 200 -
300 300 200 200 200 200
3 3 3 3 3 3
- - - - - -
- -
- - -
- -
- -
- - - -
- -
- - - -
-
216 x 53 x 80 141 x 89 x 71 206 x 106 x 80 306 x 184 x 110 306 x 210 x 130 306 x 250 x 130
0.54 0.46 0.60 2.00 2.00 3.50
A-5
Functions and characteristics www.se.com
Fuse switch-disconnectors
Type of fuse-link
DIN/NH000
PB115837.eps
DIN/NH00
DIN/NH1
DIN/NH2
DIN/NH3
A Installation and connection
Symmetrical rail
Direct connection on backplate
Hook-on connection to 60 mm busbars
Tightening torque (Nm)
ISFT100N Temperature derating (with gG fuse-link) [1] [2]
“Vertical mounting” Ith (A) 40 °C
fuse-links in vertical position 45 °C
50 °C
55 °C
60 °C
65 °C
PB115838.eps
70 °C
“Horizontal mounting” Ith (A) 40 °C
fuse-links in horizontal position 45 °C
50 °C
55 °C
60 °C
ISFT100 65 °C
70 °C
Degree of protection (from the IP3X
front face and inclosed position)
Mechanical shock IK07
[1] Derating data is based on:
PB115839.eps
ISFT160
PB115835.eps
ISFT630
A-6
www.se.com
Functions and characteristics
Fuse switch-disconnector selection
FuPacT ISFT100N to ISFT630
- - -
A
- -
see page B-4
A-7
Functions and characteristics www.se.com
FuPacT ISFT100N
DB430652.ai
A B C
A-8
www.se.com
Functions and characteristics
Accessories and auxiliaries
FuPacT ISFT100
A B C
DB430653.ai
F E D
A NO + NC auxiliary changeover contacts C Feeding busbars to supply : E Accessory for mounting on DIN rail
b 2 devices
B Incoming connector for feeding busbars F Escutcheons for:
b 3 devices
b 4 devices b 1 device
D Distribution connector b 2 devices
A-9
Functions and characteristics www.se.com
A B C D
DB430654.ai
G F E
A-10
www.se.com
Functions and characteristics
Accessories and auxiliaries
FuPacT ISFT250 to ISFT630
A B C
DB430655.ai
F E D
A-11
Functions and characteristics www.se.com
Accessories
Support Profile Laterally attachable
This accessory allows to enlarge the cut-out tolerances of the cover plates while also
supporting these plates.
bb Latchable bracket on the side.
bb Allows greater cutting tolerances.
Intelligent measurement
Electronic Fuse-Monitoring - Everything under control
Thanks to the electronic Fuse Monitor, technician could receive an information to
localize a short circuit or overload. Maintenance will be more reactive to change fuse
which is broken.
A-12
www.se.com
Functions and characteristics
General characteristics: ISFT
FuPacT ISFT100N to ISFT630
Safety
PB115840.eps
FuPact ISFT provides:
bb Protection against accidental contact in the standard model:
vv terminal housing closed
vv simple break-out for all versions
vv terminal shield needed for specific application (> 500 V)
vv IP3X
vv life part are covered.
bb Switching with integrated and extended hand protection feature:
A
vv prevents fuse-unit contact
vv protection against electric arc.
bb Voltage test thanks to independent slidable windows
bb Snap-on busbar cover to protect against direct contact.
bb Locking cover with sealing facility:
vv locking mechanism for switching cover for non-instructed individuals
vv switching cover is sealable.
PB115841.eps
For FuPacT 160 A size 00
bb Advantageous box terminals:
vv Cu conductor from 2,5 to 95 mm2
vv no cable lug needed.
bb Or universal screw terminal for M8 cable lug.
Options
bb Prism clamp 6…70 mm2. Cu/Al.
bb Terminal 3 x 16 mm2.
PB115842.eps
vv size 3 for M12 cable lug.
bb Easy to change the various types of connection.
Options
bb Prism clamp for Cu.
bb Prism clamp for Cu/Al (1x cable).
bb Prism clamp for Cu/Al (2x cables).
A-13
Functions and characteristics www.se.com
ISFT installation
FuPacT ISFT100N to ISFT630
ISFT fusegear is installed on a mounting plate, DIN rail or on busbars, depending on the power rating.
Connections are made via cables or directly to the busbars via hook-on.
ISFT100N fusegear
Installation on a mounting plate, on busbars 60 mm or DIN rail on busbars with:
A bb cables or flexible bars
bb hook-on connection to 60 mm busbars.
Upstream or downstream connection of distribution circuits requires cables or
flexible bars.
PB117721_L32.eps
DB423159.eps
DB423160.eps
DB423158.eps
DB120097.eps
DB423162.eps
A-14
www.se.com
Functions and characteristics
ISFT installation
FuPacT ISFT100N to ISFT630
ISFT160 fusegear
Installation on a mounting plate or on busbars with:
bb cables or flexible bars
bb hook-on connection to 60 mm busbars
A
Downstream connection of distribution circuits requires cables or flexible bars.
PB115844.eps
Hook-on connection (ISFT250 and 2 x ISFT160)
DB423163.eps
DB423164.eps
DB423167.eps
A-15
Functions and characteristics www.se.com
FuPacT fuse-switch disconnectors can supply distribution circuits via either the upstream or downstream terminals.
Devices intended for connection to busbars are configured as standard for distribution via the downstream terminals.
ISFT fusegear is equipped with connectors or terminals for front connection of:
bb bare cables for ISFT100N to ISFT160 devices
bb cables with lugs for ISFT160 to 630 devices
ISFT100N fusegear
DB423169.eps
DB120179.eps
ISFT100 fusegear
62315a_2.eps
DB423171.eps
DB423170.eps
Distribution connector
62316a_2.eps
DB424792.eps
Feeding busbar
A-16
www.se.com
Functions and characteristics
Connection and accessories
FuPacT ISFT100N to ISFT630 - Connection
ISFT160 fusegear
DB120162.eps
A
DB423173.eps
DB423174.eps
62330a_1-2_r.eps
Lug for copper cables
LV480814_L17R.eps
Distribution connector
DB423175.eps
DB424797.eps
LV480816_L15.eps
DB423178.eps
62330a_1-2_r.eps
DB424798.eps
LV480829_L22.eps
A-17
Functions and characteristics www.se.com
FuPacT fuse-switch disconnectors designed for connection to busbars supply distribution circuits via the
downstream terminals as standard. In the case of ISFT160 to ISFT630 devices, simple installation operations allow
power to be supplied to the distribution circuits from upstream. In the case of ISFT100N devices, the method of
distribution cannot be reversed simply by changing the direction of the mounting. There are separate references for
each particular case.
DB425101.eps
DB401353.eps
DB401355.eps
DB120103.eps
A-18
www.se.com
Functions and characteristics
Connection and accessories
FuPacT ISFT100 and ISFT160 - Connection, coupling
It is possible to supply several ISFT100 and ISFT160 fusegears by using feeding busbars via a single incomer.
max. max.
100 A 125 A
DB423186.eps
DB425093.eps
3 devices
max. max.
160 A 160 A
DB423187.eps
DB425094.eps
4 devices
DB423188.eps
DB425095.eps
max. max.
160 A 160 A
[1] For combinations of more than 2 ISFT100 devices, it is recommended to connect incoming
power to the second device to reduce temperature rise.
A-19
Functions and characteristics www.se.com
ISFT250
A
DB4430686.eps
ISFT400
[1]
ISFT100N
ISFT160
DB4430687.eps
[1]
[1] Linergy BZ busbar system: for more technical informations, see page D-6.
A-20
www.se.com
Functions and characteristics
Connection and accessories
FuPacT ISFT100N, ISFT160 to ISFT400 -
Different installation systems
ISFT250
A
DB4430688.eps
ISFT250
NSX400/630
L3
L2
L1
L1
12 Nm
L2
12 Nm
L3
12 Nm
L3
L2
L1
ISFT160
DB430665.eps
ISFT160
ISFT400
A-21
Functions and characteristics www.se.com
Fuse monitor
FuPacT ISFT160 to ISFT630
Functions
PB115845.eps
This device provides remote indication of the status of standard fuses (without
strikers). It serves to:
bb it signals a blown fuse
bb it helps prevent the risks of abnormal voltages on the neutral.
Standards
A bb Compliance with international standard IEC 60947-5-1.
bb Compliance with:
vv EN 50204
vv EN 61000 for electromagnetic compatibility (EMC).
Description
bb Characteristics:
ISFT160 fuse monitor vv operation with DIN fuses.
vv degree of protection: IP20.
bb May be used on capacitor bank circuits.
bb Simplified power supply:
vv does not require a specific power supply
vv operates with unbalanced phases
vv supplied via connection to the fuse terminals on the fusegear devices
vv operational voltage: 400…690 V AC, ±10 %, 50/60 Hz.
bb Tested for electromagnetic compatibility (EMC).
bb Mounting:
vv connected to the fuse-carrier assembly forming the cover.
bb The package consists of:
vv a fuse-carrier/handle and fuse monitor sub-assembly supplied as a kit
composed of:
- fuse monitor equipped with one NO contact and one NC contact
- fuse-carrier with the handle
vv the customer must remove his fuse-carrier/handle assembly from his product
and replace it with this kit.
bb Characteristics:
vv IP20 degree of protection
vv product with fuse monitor must be integrated inside switchboards and not in
front face in case of customers wants to have a complete class II insulation.
Class II insulation with switchboard in front face is effective only when FuPacT
ISFT is in closed position and with a door or a protection behind the fuse
monitor.
Operation
Reset
The device is automatically reset when the fuse-links are replaced.
Indications
bb Normal operation:
vv the green LED is ON when voltage is present at the fuse terminals
vv the contacts are in the rest position.
bb Operation when a fuse blows:
vv the green LED goes off and the red LED goes on
vv the contacts are actuated:
- the NO contact is for remote fault indication
- the NC contact may be used, for example, to control an undervoltage device
in order to shut down equipment that may be sensitive to single-phasing.
NVE88766
A-22
www.se.com
Functions and characteristics
Fuse monitor
FuPacT ISFT160 to ISFT630
Electrical characteristics
Power circuit
Rated operational voltage 400 to 690 V AC 50/60 Hz ±10 %
Consumption < 3 VA
Rated frequency 50/60 Hz
Measurement impedance > 1000 W/V
Rated impulse withstand voltage (1.2 / 50 ms) 8 kV
Auxiliary contact output terminals
Terminal indications NO 13 - 14 A
NC 21 - 22
Cable capacity Flexible y 1.5 mm2 Cu
Rigid y 2.5 mm2 Cu
Output contact characteristics (1NO + 1NC)
Conventional thermal current Ith (A) 5
Rated insulation voltage (V) 250
Minimum load 10 mA at 24 V
Characteristics AC DC
Utilisation category (IEC 60947-5-1) AC12 AC15 DC12 DC13
Operational current (A) 24 V - 3 - 2
48 V - 3 - -
110 V - 3 - -
220/240 V - 3 - -
250 V - 3 - -
380/415 V - - - -
440 V - - - -
660/690 V - - - -
Rated operational voltage / max. breaking voltage (V AC) 250/440
Breaking capacity (VA) 2000
General characteristics
Operating temperature range (°C) -25…+55 (y 500 V) -25…+45 (> 500 V)
Storage and transport temperature range (°C) -40…+70
Fuse blowing detection time (s) <2
Overvoltage category / degree of pollution IEC 60947-1 3
Dielectric test voltage (between power circuit and output terminals) 5 kV rms / 1 min 50 Hz
Electromagnetic compatibility - emission
Conducted EN 55022 Class B
Radiated EN 55022 Class B
Harmonic currents EN 61000-3-2 Class A
Electromagnetic compatibility - immunity
Electrostatic discharge (ESD) EN 61000-4-2 category B level 2/3
Radiated field susceptibility (RF) EN 61000-4-3 category A level 3
Surge immunity test EN 61000-4-5 level 4
Conducted low energy susceptibility (EFT) EN 61000-4-4 category B level 3
Conducted high energy susceptibility (RF) EN 61000-4-6 category A level 3
Radio-frequency interference (GSM) ENV 50204 category A
Magnetic field immunity
Continuous EN 61000-4-8 level 5
Mechanical characteristics
Degree of protection IP20
Weight (fuse monitor alone) (kg) 0.2
Dimensions
33
DB424799.eps
83
45
A-23
Functions and characteristics www.se.com
Insulation
FuPacT ISFT100N to ISFT630
Some accessories for insulation are used to prevent direct contact with the main circuits.
For ISFT100, we have single and double escutcheon (with 1 free slot). These escutcheons, which could be used in
combination, allow one type of cut-out on the front panel of switchboard. But in case of feeding busbars, The use of
escutcheon is not compliant with feeding busbars.
For ISFT100N and ISFT160 to 630 , side profiles (or laterally attachable) provide vertical IP level across the door.
The switchboard manufacturer must provide the horizontal IP.
For those products, it’s mandatory to use terminal shield when voltage is upper or equal to 500 V.
A
Insulation of live parts
Escutcheon
Clipped on the device, escutcheons provide IP20 and IK07 degrees of protection.
Type Escutcheon type Terminal shield
ISFT100N - -
ISFT100 - -
ISFT160
ISFT250
ISFT400
ISFT630
62306a_4.eps
ISFT100N fusegear - Terminal shield and escutcheon
Escutcheon
DB423192.eps
DB423193.eps
62307a_1-88.eps
Terminal shields
Escutcheon
DB425097.eps
Laterally attachable
support profile
A-24
www.se.com
Functions and characteristics
Fuse-link monitoring and testing
FuPacT ISFT160 to ISFT630
Monitoring
ISFT 160 to 630 fuse-switch disconnectors are equipped with independant large
windows so that the fuse-link technical characteristics are clearly visible.
PB115839.eps
A
DB423199.eps
ISFT160
Testing
PB115846.eps
DB423200.eps
Independant sliding covers on the front panel provide access to the fuse-link status
test points while maintaining the IP20 protection index.
A-25
Functions and characteristics www.se.com
The main moving contacts are controlled by the pivoting fuse-carrier assembly forming the cover for the ISFT devices
In open position, the fuse-switch disconnector fuse-carrier assembly provides isolation with visible break.
Control
A
DB423201.eps
PB115847.eps
ISFT100N.
Locking
DB120139.eps
ON
PB119107.eps
DB423202.eps
ISFT400
Lead-seal locking
for the ISFT100 to ISFT630
devices
Locking in open (OFF) position isolation as defined by IEC 60947-3.
A-26
www.se.com
Functions and characteristics
Control, locking and operation
FuPacT ISFT100N to ISFT630
For ISFT fusegear devices, the fuse-carrier cover is used both to control the device and to protect the fuse-link.
b ISFT100N: the pivoting fuse-carrier assembly accepts two fuse-links side by side and a third situated under the first
two fuse-links.
b ISFT100 to ISFT630: the pivoting fuse-carrier assembly accepts the three fuse-links side by side.
Fuse-carriers
Compatibility between ISFT fuse-switch disconnectors
A
and fuse-links (NH)
DB423204.eps
A-27
Functions and characteristics www.se.com
ISFT100N 1
ISFT100 2
ISFT160 2
ISFT250 2
ISFT400 2
ISFT630 2
A-28
www.se.com
Functions and characteristics
Auxiliary contacts and indications
FuPacT ISFT100N to ISFT630
A
DB423207.eps
DB423227.eps
PB119122.eps
ISFT160
PB104316-20.eps
A-29
Installation recommendations www.se.com
A
DB423438.eps
DB423439.eps
DB423440.eps
DB423441.eps
Possible mounting
ISFT100N and ISFT100 ISFT100N to ISFT630
DB423444.eps
DB423445.eps
DB423447.eps
A-30
www.se.com
Installation recommendations
Implementation and power dissipation
FuPacT ISFT
Reverse supply
FuPacT fusegear may be supplied equally well via the upstream or downstream
terminals, without any reduction in performance.
A-31
Installation recommendations www.se.com
A-32
www.se.com
Dimensions and connection
FuPacT ISFT100N
Dimensions and mounting
Dimensions
Device to be installed on a backplate or DIN rail
Fuse-carrier closed Front Fuse-carrier open
65
A
DB425174.eps
DB425175.eps
DB425176.eps
X X X
216
174
82 26.5
53
52
Z Y
220
Z
Device to be installed on a busbar
Fuse-carrier closed Front Fuse-carrier open
[a] 31
DB425177.eps
DB425178.eps
DB425179.eps
60
23 X
X X
206
174
31
26.5 76
20 106 53 244
Z
Z Y
[a] Terminal shields.
Mounting
On backplate On DIN rail
16.5 16.5
(b)
3 Ø7
35
DB425180.eps
DB425181.eps
DB425182.eps
X X X 20
X
32.5
X
Y Y
A-33
Dimensions and connection www.se.com
FuPacT ISFT100N
Front panel cut-outs - Connection and accessories
Mounting (cont.)
On 60 mm busbars
23
DB425183.eps
DB425184.eps
X X
A 60
150
60
30
5...10
Z Y
DB425186.eps
DB425187.eps
48 48
DB425185.eps
X X X X
185 185
27 27
63 54 113
46
Y Y
Z Y
[1] With or without side profile, see page A-24. - [2] With side profile, see page A-24. -
Device to be installed on a busbar Cut-out (c) for 1 device Cut-out (d) for 1 device
[b] [b] [b] (c)
DB425891.eps
DB425189.eps
DB425190.eps
DB425188.eps
48 55
X X X X X
DB425892.eps
185 196
27
32 27
63 54 63
70 54
Y
Z Y Y Y
Front connection of cables
FuPacT ISFT100N devices are equipped as standard Standard device
with connectors for bare copper cables from 2.5 to FuPacT connectors L (mm) 18
50 mm2 for mounting on backplates.
DB401307.eps
A-34
www.se.com
Dimensions and connection
FuPacT ISFT100
Dimensions
Dimensions
Device to be installed on a backplate or DIN rail
Fuse-carrier closed Front Fuse-carrier open
71 87
44
A
DB425127.eps
DB425128.eps
DB425765.eps
130 134
113 X X X
52.5 49
64.5
90
46 44.5
Z 46
89
176
Y Z
180 270
44.5 44.5
DB425134.eps
DB425135.eps
63.5 63.5
171.5 171.5
X X
64.5 64.5
Y Y
360
44.5
DB425136.eps
63.5
171.5
X
64.5
A-35
Dimensions and connection www.se.com
FuPacT ISFT100
Mounting and front panel cut-outs
Mounting
On backplate On a symmetrical DIN rail
50
25 Ø5
DB425191.eps
DB425137.eps
DB425138.eps
A
X X X
35
Y Z
Y
189
100
50 50
DB425139.eps
DB425192.eps
DB425193.eps
X 162 X X
77.5
Y
Y
46
Z
110
199
55
55
DB425194.eps
DB425195.eps
DB425196.eps
X 115 X 115 X
180 166
48 48
78.5
85.5
2 46
43
132
86
Y
Y
A-36
www.se.com
Dimensions and connection
FuPacT ISFT100
Connection and accessories
Standard device
FuPacT connectors L (mm) 18
S (mm2) 1.5 to 50 rigid
Cu/Al 1.5 to 35 flexible [1]
DB401307.eps
Torque (Nm) 3
A
Connection via bare cable connectors
3 x 10 mm² distribution connector
DB424801.eps
[1] Connection of 2.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.
DB424946.eps
Distribution connector
DB425099.eps
A-37
Dimensions and connection www.se.com
FuPacT ISFT100
Connection and accessories
DB425142.eps 88
A
X X
98
45
Z Y
Feeding busbars for two or three ISFT100 devices (with 25 to 95 mm² incoming connector)
90
DB425143.eps
DB425144.eps
DB425145.eps
44 25.5 25.5 180
14 25.5 25.5 90
110 107
X X X
Z Y
Y
Feeding busbars for four ISFT100 devices (with 25 to 95 mm² incoming connector)
DB425146.eps
90
180
270
Y
A-38
www.se.com
Dimensions and connection
FuPacT ISFT160
Dimensions
Dimensions
Fuse-carrier closed Front Fuse-carrier open
80 106
DB425132.eps
DB425766.eps
DB425133.eps
49 53
200
6 49
A
184
194 X 194 X X
267
97 92 97 105
133
[a]
6 50
Z
46
Z Y
[a] Terminal shields.
DB425820.eps
49
24
60
6
214 X X
60
30 128
5... 10 Z
50
200
Z
A-39
Dimensions and connection www.se.com
FuPacT ISFT160
Mounting and front panel cut-outs
Mounting
On backplate
69 69 Ø 6.5
DB425767.eps
DB425768.eps
DB425199.eps
34.5 Ø7
A X
Ø7
X X
25
13 13 40
49 66 34.5
Y Y Y
On 60 mm busbars
With hook-on
DB430667.eps
6
X
DB425888.eps
DB425889.eps
X X 186 X
93
54
49 116
108
Z Y
Y
A-40
www.se.com
Dimensions and connection
FuPacT ISFT160
Connection and accessories
DB424804.eps
FuPacT ISFT160 devices are also equipped with 12 mm wide terminals with holes
for M8 screws for the connection methods presented below.
3 x 16 mm² distribution connector
L (mm) 25
S (mm2) 1.5 to 16 rigid
DB401307.eps
Cu/Al 1.5 to 10 flexible [1]
Torque (Nm) 2 (cables)
4 (connectors)
A
DB424806.eps
DB425208.eps
L (mm) 20
l (mm) 12
DB401311.eps
e (Nm) 6
Torque (mm) 4
Torque (Nm) 14
DB425209.eps
DB120528.eps
L
Used with long terminal shields
Distribution connector V-type connector for bare [1] Connection of 2.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.
Cu/Al cables
FuPacT ISFT160 devices are equipped as standard with connectors for bare copper
DB120529.eps
DB401307.eps
A-41
Dimensions and connection www.se.com
FuPacT ISFT160
Connection and accessories
DB425212.eps
DB425211.eps
96
63
A 194
X
126
X
17 17
17
Z Y
22
DB425823.eps
DB430668.eps
60 14 14
X X
60
37
50 Y
Z
A-42
www.se.com
Dimensions and connection
FuPacT ISFT250 to 630
Dimensions and mounting
Dimensions
Fuse-carrier closed Front Fuse-carrier open
P4 P5
DB425233.eps
DB425234.eps
DB425825.eps
P1
299 X X X
92
134
134 176 148
[a]
P3
Z
P2 L1
Z
L2
[a] Terminal shields.
Y
DB425826.eps
P4 P1
242
299 9
X X
H1 92
121
28 P1 P3
Z
P6
Z
Type L1 L2 P1 P2 P3 P4 P5 P6 P7
ISFT250 92 184 70 70 74 112 293 316 142
ISFT400 105 210 90 90 94 131 331 319 162
ISFT630 125 250 90 90 94 131 332 319 162
A-43
Dimensions and connection www.se.com
Mounting
On a backplate for ISFT250 On a backplate for ISFT400 On a backplate for ISFT630
DB425832.eps
DB425236.eps
DB425237.eps
75 Ø 11 83 Ø 11 97.5 Ø 11
A 25
50
X 25
50
X 25
50
X
Y Y Y
On busbars
With hook-on for ISFT250 With hook-on for ISFT400/630
DB425238.eps
DB425239.eps
14 60 100
X 14
X
60
100
Y Y
DB425882.eps
DB425883.eps
X X 301 X
135
L3 L3
P8
Y
Z L4
Y
Type L4 L5 P8
ISFT250 93 186 70
ISFT400 106 212 90
ISFT630 126 252 90
A-44
www.se.com
Dimensions and connection
FuPacT ISFT250 to 630
Connection and accessories
holes for M10 screws for the connection methods presented below.
DB401307.eps
S (mm2) 6 to 150 6 to 240
Cu/Al
Torque (Nm) 14 14
A
Connector for flexible bars
ISFT250 ISFT400/630
L (mm) 20 30
DB401311.eps
I (mm2) 16 21
e (mm) 15 15
Torque (Nm) 14 14
DB425241.eps
Ø (mm) 10.2
Torque (Nm) 32
DB124900.eps
Ø (mm) 10.2
Torque (Nm) 32
L
DB124901.eps
A-45
Dimensions and connection www.se.com
DB425243.eps
C
A
X X
D
Y Z
Type A B C D
ISFT250 57 33 93 186
ISFT400 65 36.5 104.5 209
ISFT630 80 36.5 104.5 209
DB425245.eps
60 9
X X
D
60
5... 10 B A A
Z Y
A-46
www.se.com
Wiring diagrams
FuPacT ISFT
Power
DB423470.eps
FU01 FU02 FU03
A
Auxiliary contacts
ISFT100N ISFT100 to 630
DB423472.eps
DB423471.eps
Blown fuse
ISFT160 to 630 Electronic fuse
Monitor
DB423479.eps
22
21
14
13
A-47
www.se.com
D
B
ISFL160 ISFL250/400/630/1250
2
www.se.com
FuPacT ISFL
Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
B-1
www.se.com
FuPacT ISFL
Installation recommendations
Possible installation positions and mounting ............. B-36
FuPacT ISFL160 to ISFL1250........................................................ B-36
Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
B-2
www.se.com
FuPacT ISFL
Wiring diagrams
FuPacT ISFL........................................................................... B-49
Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
B-3
Functions and characteristics www.se.com
Fuse switch-disconnectors
Number of poles / type of fuse-link IEC60 269-2-1 Section 1
Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3 and
PB113883-R8.eps
EN 60947-1 / EN 60947-3
Conventional thermal current (A) In free air Ith at 40 °C
Maximum fuse power dissipation (W)
In enclosure Ithe at 40 °C
Maximum fuse power dissipation (W)
Rated insulation voltage (V) Ui AC 50/60 Hz / DC
Rated impulse withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
Rated operational voltage AC20 and DC20 (V) Ue
Rated operational current (A) Ie AC 50/60 Hz
220/240 V
B 380/415 V
PB107274_11.eps
440/480 V [1]
500 V
660/690 V
DC/poles in series
125 V /nbr of poles
220 V /nbr of poles
440 V /nbr of poles
Rated duties Uninterrupted duty
ISFL160 - 3P ISFL160 - 3 x 1P Rated short-circuit breaking capacity (kA rms)/ Icn/Icm/In 415 V
Rated short-circuit making capacity (kA peak)/ 500 V
Fuse-link In (A) [2]
690 V
Endurance (category B) (CO cycles) Mechanical
Electrical AC AC23B 415 V
PB113884-R10.eps
PB107275_20.eps
AC22B 500 V
AC21B 690 V
Suitability for isolation
Positive contact indication
Pollution degree
Control
Direct handle (operator-dependent opening and closing)
Locking Padlocks
Lead seal
Indication auxiliaries
Auxiliary contacts
Current transformer
Installation and connection accessories
Possible mounting position Horizontal
Vertical
Connector For bare Cu/Al cables
For flexible bars
Lugs for Cu/Al cables
Terminal shields
Dimensions and weight
Overall dimensions H x W x D (mm) 3P
Approximate weight without fuse-links (kg) 3P
[1] Suitable for 480 V NEMA.
ISFL250 - 3P ISFL250 - 3 x 1P [2] Fuse-switch disconnectors with fuse-links.
[3] Only for ISF160 with direct connection to the busbars.
[4] AC22B 690 V.
B-4
www.se.com Functions and characteristics
100 / 210 / 160 120 / 250 / 250 120 / 250 / 400 120 / 250 / 630 120 / 250 / 630
100 / 210 / 160 120 / 250 / 250 120 / 250 / 400 120 / 250 / 630 120 / 250 / 630
100 / 210 / 160 100 / 210 / 200 100 / 210 / 315 100 / 210 / 500 100 / 210 / 500
1400 1400 800 800 800
200 200 200 200 200
200 [4] 200 200 200 200
200 200 200 200 200
3 3 3 3 3
- - - - -
[3]
- - - -
- - - -
- - - -
included included included included included
405 x 50 x 123 741 x 100 x 190 741 x 100 x 190 741 x 100 x 190 834 x 200 x 190
1.30 4.70 5.00 5.60 15.20
B-5
Functions and characteristics www.se.com
Fuse switch-disconnectors
PB113883-R8.eps
Type of fuse-link
DIN NH000
DIN NH00
DIN NH1
DIN NH2
DIN NH3
Installation and connection
ISFL160 for 60 mm busbar hook-on contact mounting with multiple use terminal (screw M8)
ISFL160 for 60 mm busbar hook-on contact mounting with box terminal 95 mm2
ISFL160 for 100 mm busbar hook-on contact mounting with multiple use terminal (screw M8)
PB107274_11.eps
ISFL160 for 100 mm busbar hook-on contact mounting with box terminal 95 mm2
B Conversion kit for 185 mm busbar direct contact mounting (for 1 or 2 x ISFL160)
ISFL160 for 185 mm busbar 1-pole switchable direct mounting
ISFL160 for 185 mm busbar 1-pole switchable hook-on mounting
Terminal tightening torque (Nm)
Temperature derating (with gG fuse-link) [1]
“Vertical mounting” Ith (A) 40 °C
fuse-links in vertical position 45 °C
50 °C
ISFL160 - 3P ISFL160 - 3 x 1P 55 °C
60 °C
65 °C
70 °C
“Horizontal mounting” Ith (A) 40 °C
fuse-links in horizontal position 45 °C
50 °C
55 °C
PB113884-R10.eps
60 °C
PB107275_20.eps
65 °C
70 °C
[1] Derating data is based on:
- the maximum rating for fuse-links intended for the device
- maximum power dissipation.
ISFL250 - 3P ISFL250 - 3 x 1P
B-6
www.se.com Functions and characteristics
- - - -
- - - -
- - - -
- - - -
- - - -
B
see page B-4
B-7
Functions and characteristics www.se.com
A B C D
DB430689.eps
I E
H G F
A B C D
DB430657.eps
F E
A B
B J
x3
H G F E
A NO + NC auxiliary changeover contacts E Screws with plastic support H Lug for copper cable
B Empty plastic box F Connector for Cu/Al bare I Current transformer
cables 2 x 50 to 185 mm2
C Blank panel cover for free slot J Hooks
G Connector for Cu/Al bare
D Side cover for front panel cut-out
cables 1 x 35 to 300 mm2
B-10
www.se.com Functions and characteristics
A
DB430691.eps
G B
E D C
B-11
Functions and characteristics www.se.com
With FuPacT ISFL, you have one of the most efficient vertical NH fuse switch-
disconnectors ever designed with compact dimensions, a modular system and an
elegant design. Your benefit are as follows:
Future proof
The trend is moving from simple power distribution stations to more intelligent power
distribution stations. FuPacT ISFL is made for the future: with interfaces for
measurement and control equipment which can be integrated in a space-saving
manner.
PB107611_60mm.eps
Safety in mind
The switch gears are very user friendly and provide optimal user protection due to
parallel switching. Two disconnected positions per phase produce two smaller
electrical arcs. This causes only half the arc voltage.
B-12
www.se.com Functions and characteristics
PB115409_L31.eps
Standard universal terminals allow the direct connection of cable lugs as well as
cables with cross-sections up to 300 mm2. Easy-to-install terminal hardware gives
B
you great flexibility. No other small-sized FuPacT ISFL can do that.
Intelligent measurement
The future belongs to more intelligent switchboards. FuPacT ISFL is well prepared
for the future: it offer standardized interface for measurement devices.
Contemporary power management
FuPacT ISFL measuring devices offers a large selection of measuring and
monitoring options: from basic current measurements and power metering,
harmonic wave analysis to remote management and alarm relays, and many more.
All electrical parameters are visualized on an LCD and can be centralized. EM
measuring devices are normally installed separately in the switchboard. FuPacT
ISFL offer an integrated solution which can simply be plugged on.
Electronic Fuse-Monitoring - Everything under control
You know what happens and where it happens almost instantly to a notification,
technician receives the information required to precisely locate and quickly correct
short-circuits and overloads. Your technician will be faster to analyze and change
fuse which is broken.
PB107276.eps
B-13
Functions and characteristics www.se.com
ISFL installation
FuPacT ISFL160
FuPacT ISFL fusegear is installed vertically and connected directly to the busbars.
The connection is bolted or could be made by the hook-on connection.
ISFL160 fusegear
Connection to busbars.
The power circuit is connected:
bb directly to the 100 mm busbars for 3-pole version or to the 185 mm busbars for
1-pole version
bb using a hook-on connection to 60 mm busbars (3-pole version)
bb via a conversion kit for connection to 185 mm busbars (3-pole version)
bb via a conversion kit for two devices and for connection to 185 mm busbars.
PB115408_L32.eps
B
DB423382.eps
DB423383.eps
B-14
www.se.com Functions and characteristics
ISFL installation
FuPacT ISFL250 to ISFL1250
ISFL250/400/630 fusegear
Connection to busbars.
The power circuit is connected:
DB423386.eps
bb directly to the 185 mm busbars for 1-pole and 3-pole version
bb using a hook-on connection to 185 busbars
DB423389.eps
mechanical mounting.
DB423387.eps
Hook-on connection to busbars:
the device tightly hooks on to the
busbars via three hooks that allows for
both electrical connection and robust
mechanical mounting.
DB423391.eps
B-15
Functions and characteristics www.se.com
FuPacT ISFL fuse-switch disconnectors can supply distribution circuits via either the upstream or downstream
terminals.
Devices intended for connection to busbars are configured as standard for distribution via the downstream terminals.
ISFL fusegear is equipped with connectors or terminals for front connection of:
bb cables with lugs for the ISFL160 and ISFL1250 devices
bb flexible bars for the ISFL160 devices
bb bare cables for ISFL160 to 630 devices.
Connector 12 x 6 mm - - - -
DB423397.eps
62330a_1-2_15.eps
[1] Connections and accessories are identical for ISFL single phase.
B-16
www.se.com Functions and characteristics
62330a_1-2_15.eps
DB423398.eps
DB423399.eps
DB423400.eps
DB402725.eps
Connector for Cu/Al bare cable 1 x 35 to 300 mm²
PB101086-22.eps
or
ISFL1250 fusegear
DB423401.eps
DB423402.eps
[1] Connections and accessories are identical for ISFL single phase.
B-17
Functions and characteristics www.se.com
Two conversion kits are available for ISFL160 3-pole switchable to adapt the 100 mm standard fixing centres to
185 mm fixing centres.
B
DB423404.eps
DB423405.eps
185
185
185
185
185
185
ISFL160 1P
PB107282_10.eps
PB107283_19.eps
B-18
www.se.com Functions and characteristics
DB423407.eps
DB423406.eps
QGH568500
B-19
Functions and characteristics www.se.com
two versions:
bb connection using M8 screws
bb connection using a 95 mm2 terminal.
For each of these versions, the distribution reversal mode is achieved by rotating the
hooks located at the rear, which gives the possibility of upstream distribution.
The fuse-carrier assembly does not change position.
All the various connection modes could be reversed also.
B
DB423408.eps
[1] For ISFL 1-pole switchable: identical reversed distribution could be done.
B-20
www.se.com Functions and characteristics
B-21
Functions and characteristics www.se.com
Insulation
FuPacT ISFL160 to ISFL630
ISFL160 fusegear
PB107288_24.eps
DB423411.eps
DB423412.eps
Length adapter
B
PB107286_10.eps
PB107287_18.eps
B-22
www.se.com Functions and characteristics
Insulation
FuPacT ISFL250 to ISFL1250
DB423416.eps
PB107289_6.eps
PB107295_9.eps
B
Blank panel cover
ISFL1250 fusegear
DB423418.eps
DB423417.eps
B-23
Functions and characteristics www.se.com
Fuse monitor
FuPacT ISFL160 to ISFL1250
PB107278_11.eps
Functions
The device provides remote indication of the standard fuse status (without strikers).
It is used to:
bb signal a blown fuse
bb protect motors from overloads caused by single-phase operation.
Standards
bb Compliance with international standard IEC 60947-5-1.
bb Compliance with:
vv EN 50204
vv EN 61000 for electromagnetic compatibility (EMC).
Description
B bb Fuse monitor function only for 3P.
bb Operation with DIN fuses.
bb May be used on capacitor bank circuits.
bb Simplified power supply:
vv does not require a specific power supply
PB107276_20.eps
Operation
Reset
The device is automatically reset when the fuse-links are replaced.
Indications
bb Normal operation:
vv the green LED is ON when voltage is present at the fuse terminals
vv the contacts are in the rest position
PB119108.eps
B-24
www.se.com Functions and characteristics
Fuse monitor
FuPacT ISFL160 to ISFL1250
Electrical characteristics
Power circuit
Rated operational voltage (Ue) 400 to 690 V AC 50/60 Hz ±10 %
Consumption < 3 VA
Rated frequency 50/60 Hz
Measurement impedance > 1000 W/V
Rated impulse withstand voltage (1.2 / 50 ms) (Uimp) 8 kV
Auxiliary contact output terminals
Terminal indications NO 13 - 14
NC 21 - 22
Cable capacity Flexible y 1.5 mm2 Cu
Rigid y 2.5 mm2 Cu
Output contact characteristics (1NO + 1NC)
Conventional thermal current Ith (A)
Rated insulation voltage (V)
5
250 B
Minimum load 10 mA at 24 V
Characteristics AC DC
Utilisation category (IEC 60947-5-1) AC12 AC15 DC12 DC13
Operational current (A) 24 V - 3 - 2
48 V - 3 - -
110 V - 3 - -
220/240 V - 3 - -
250 V - 3 - -
380/415 V - - - -
440 V - - - -
660/690 V - - - -
Rated operational voltage / max. breaking voltage (V AC) 250/440
Breaking capacity (VA) 2000
General characteristics
Operating temperature range (°C) -25…+55 (y 500 V) -25…+45 (> 500 V)
Storage and transport temperature range (°C) -40…+70
Fuse blowing detection time (s) <2
Overvoltage category / degree of pollution IEC 60947-1 3
Dielectric test voltage (between power circuit and output terminals) 5 kV rms / 1 min 50 Hz
Electromagnetic compatibility - emission
Conducted EN 55022 Class B
Radiated EN 55022 Class B
Harmonic currents EN 61000-3-2 Class A
Electromagnetic compatibility - immunity
Electrostatic discharge (ESD) EN 61000-4-2 category B level 2/3
Radiated field susceptibility (RF) EN 61000-4-3 category A level 3
Surge immunity test EN 61000-4-5 level 4
Conducted low energy susceptibility (EFT) EN 61000-4-4 category B level 3
Conducted high energy susceptibility (RF) EN 61000-4-6 category A level 3
Radio-frequency interference (GSM) ENV 50204 category A
Magnetic field immunity
Continuous EN 61000-4-8 level 5
Mechanical characteristics
Degree of protection IP20
Weight (fuse monitor alone) (kg) 0.2
Dimensions
33
DB425712.eps
83
45
B-25
Functions and characteristics www.se.com
Measurement accessory
FuPacT ISFL160 to ISFL1250
The current transformers (CTs) produce a current (1 - 5 A) on the secondary winding that is proportional to the
current measured on the primary winding.
They can therefore be used in conjunction with measurement devices (ammeters, energy meters), load-shedding
devices, control relays, etc.
Selection table
PB107279_15.eps
ISFL160
class 1
1-pole version
Ip/5 Ip/1 Power (VA)
150/5 - 5
ISFL160 accuracy class 1 ISFL250 to 1250 class 1
3-pole version 1 and 3-pole version
Ip/5 Ip/1 Power (VA) Ip/5 Power (VA)
1 1
150/5 - 1.5 150/5 2.5
PB113887-R5.eps
250/5 5
150/1 2.5 400/5 5
600/5 5
Curent transformer
for ISFL160
(1-pole version) Environment
bb Compliance with standards: IEC 60044-1, NFC 42502, VDE 0414, BS 7626 and
IEC 60038-1.
bb Degree of protection: IP20.
bb Operating temperature range: -25 °C to +70 °C, relative humidity 95 %.
PB107281_18.eps
Technical characteristics
Single block current Current transformer for CT electrical characteristics:
transformer for ISFL160 ISFL250/400/630/1250 bb maximum operational voltage: 800 V
(1 or 3 CTs) bb secondary current: 5 A and 1 A
bb frequency: 50 to 60 Hz
bb continuous overload current: 1.2 In
bb safety factor: Fs y 5.
Transformation ratio:
bb Ip/5 A.
Select the ratio just above the measured current (In).
Example: In = 550 A V select a ratio of 600/5.
CT accuracy class:
bb the accuracy class depends on the transformer rating and the consumption of the
measurement system. Consumption must take into account the devices and cables
bb for a given accuracy class, measurement system consumption must not exceed
the transformer rating.
Reminder:
Transformer secondary must be short-circuited before any work.
B-26
www.se.com Functions and characteristics
Measurement accessory
FuPacT ISFL160 to ISFL1250
CT accuracy class
Measurement system
PB107336_13.eps
PB107335_13.eps
Schneider Electric device Consumption in VA
72 x 72 mm ammeter 1.1
Analogue ammeter 1.1
Digital IM ammeter 0.5
Digital ammeter 0.3
PM/CM Power Meter
PM9
0.15
0.55
B
Primary copper cross-section Rating in VA per meter of double wire
in mm² at 20 °C
1 1
1.5 0.685
2.5 0.41
4 0.254
6 0.169
10 0.0975
ISFL160 (with CT)
For each ten-degree increase in temperature, the power drawn by the cables
increases by 4 %.
CT accuracy class
The accuracy class of the CT is determined:
PB112100-B_26.eps
B-27
Functions and characteristics www.se.com
Monitoring
ISFL fuse-switch disconnectors are equipped with large windows so that the
fuse-link technical characteristics are clearly visible.
DB423419.eps
B
PB107611_30.eps
ISFL160
Testing
DB423420.eps
Sliding covers on the front panel provide access to the fuse-link status test points
while maintaining the IP20 protection index.
Note: monitoring and testing functions are the same for ISFL 1 pole switchable.
B-28
www.se.com Functions and characteristics
The main moving contacts are controlled by the drawout fuse-carrier assembly for the ISFL devices.
In open position, the fuse-switch disconnector fuse-carrier assembly provides isolation with visible break.
PB107611_30_r.eps
DB423421.eps
DB423422.eps
ISFL160
DB120140.eps
DB423424.eps
B-29
Functions and characteristics www.se.com
For FuPacT ISFL fusegear devices, the fuse-carrier assembly is used both to control the device and to mechanically
protect the fuse-link.
Fuse-carriers [1]
Compatibility between ISFL fuse-switch disconnectors
and fuse-links (NH)
PB107611_30.eps
DB423425.eps
ISFL160
Type of DIN NH000 NH00 NH1 NH2 NH3
fuse-link
ISFL160 - - -
ISFL250 - - - -
ISFL400 - - - -
ISFL630 - - - -
ISFL1250 - - - -
[1] Control, locking and operation are the same for ISFL 1-pole switchable.
B-30
www.se.com Functions and characteristics
62325a_1-29.eps
interlocking.
ISFL160 2
PB107277_25_r.eps
ISFL250 4
ISFL400 4
ISFL630 4
ISFL1250 8
B-31
Functions and characteristics www.se.com
DB423427.eps
DB423428.eps
B
ISFL250/400/630/1250
B-32
www.se.com Functions and characteristics
PB107277_25_r.eps
DB423429.eps
ISFL250/400/630/1250
B
B-33
Functions and characteristics www.se.com
Intelligent measurement
FuPacT ISFL160 to ISFL630
The future belongs to more intelligent switchboards. The new ISFL generation,
vertical design, are well prepared for the future: they offer standardized interfaces for
all types of measurement devices.
Schneider Electric is offering a complete and large offer of metering devices:
Powerlogic range.
PB104891_r.eps
The Power Meter serie offers many high-performance capabilities needed to meter
and monitor an electrical installation in a compact unit.
B All models include an easy-to-read display that presents measurements for all three
phases and neutral at the same time, total harmonic distortion (THD) metering, and
alarming.
Some models offer an incremental choice of custom logging and power quality
analysis capabilities.
Expand any model with field-installable option modules that offer a choice of
DB404267.eps
additional digital inputs and outputs, analog inputs and outputs, and ethernet port.
B-34
www.se.com
Installation recommendations
Possible installation positions and mounting
FuPacT ISFL160 to ISFL1250
DB423443.eps
Possible mounting B
ISFT100N
ISFp160 to ISFp630
ISFL1250
DB423446.eps
Securely tightened
B-35
Installation recommendations www.se.com
Reverse supply
FuPacT fusegear may be supplied equally well via the upstream or downstream
terminals, without any reduction in performance.
B-36
www.se.com
Installation recommendations
Implementation and power dissipation
FuPacT ISFL
1250
3-pole
ISFL1250 3-pole 0.093 37 630 48 85
B
With conversion kit 160 ISFL160 0.230 5.9 160 12 18
B-37
Dimensions and connection www.se.com
FuPacT ISFL160 3 x 1P
Dimensions and mounting
Dimensions
Fuse-carrier closed Front Open and locked
200
123 172
97 150
DB423314.eps
DB423315.eps
DB423316.eps
100
285
B
X X
672 X
745
380
50
Z Y
Z
Mounting
For 185 mm busbars
DB423317.eps
185
185
3 Ø8.5
B-38
www.se.com
Dimensions and connection
FuPacT ISFL160 3 x 1P
Dimensions and mounting
[a]
[a]
DB430662.eps
DB423319.eps
DB423320.eps
173
285
X 185
92.5
642
X X
B
745
173
[b]
[b]
90 74
Y
123
Y
Z
B-39
Dimensions and connection www.se.com
FuPacT ISFL160 1 x 3P
Dimensions and mounting
Dimensions
Fuse-carrier closed Front Open and locked
223
60 mm 100 mm 179
DB423324.eps
123 158
22 70 102
DB423322.eps
DB423321.eps
DB423323.eps
X X X X
360
405
B 216
150
251
26
102 50
Z Z Y Z
With 185 mm connection kit With 185 mm connection kit for 2 ISFL devices
34 102
DB423325.eps
DB423326.eps
212
X X
464.5
44 50
100
Z Y
Mounting
With connection kit for 185 mm
For 60 mm busbars For 100 mm busbars busbars
DB423329.eps
DB423328.eps
DB423327.eps
185
9 x 15 100
7 60
X X X X
60
Ø9
100
185
9 x 15 3 Ø8.5
3 Ø12.5
Y Y Y Y
B-40
www.se.com
Dimensions and connection
FuPacT ISFL160 1 x 3P
Dimensions and mounting
DB423331.eps
[a] [a]
DB423332.eps
DB423330.eps
150 160
X X X
205
361
425
[b]
B
[b]
L 18 25
123 71.5
Z Y Y
[a] Side cover for front panel cut-out.
[b] Terminal shields.
DB423335.eps
DB423333.eps
X X X
671
Y Y
95 50 50
B-41
Dimensions and connection www.se.com
FuPacT ISFL160 1 x 3P
Connection and accessories
Connection
Connection via lugs/flexible bars Connection via connectors
X X X X
DB423336.eps
DB423337.eps
DB423338.eps
DB423339.eps
175 175
L3
30 30
L2
2 M5
30 30
L1 8
B
3 10 24 7 7
21 20 1 M8 48
45 10
20 Z Y
Z Y Y
X X
175
DB423341.eps
DB423340.eps
L3
30
L2
30 2 M5
L1
8
3 1 M8
21 10
45 20
10 Y
Z 20
Current transformer
Direct connection to 100 mm busbars
50 123
20 25
DB423342.eps
53
97
328.5
100
X X X
100
Z Y Z
B-42
www.se.com
Dimensions and connection
FuPacT ISFL250 to 630 1 x 3P
Dimensions and mounting
Dimensions
Fuse-carrier closed Front Open and locked
364
256
DB423345.eps
190 196.5
150 150
DB423343.eps
DB423344.eps
286
B
X X X
741
278
455 456
135 100
Z Y Z
Mounting
For 185 mm busbars
DB423346.eps
185
Ø14.5
185
B-43
Dimensions and connection www.se.com
[a]
DB423348.eps
[a]
DB423347.eps
DB423349.eps
303
435
X X X
B 850
250 645
211.5
[b]
[b]
150 18 50
123 [a] S
ide cover for front
190 panel cut-out.
[b] Terminal shields.
Z Y Y
DB423351.eps
DB423352.eps
X X X
795
Z Y Y
B-44
www.se.com
Dimensions and connection
FuPacT ISFL1250
Dimensions and mounting
Dimensions
Fuse-carrier closed Front Open and locked
190 364
150 256
DB423353.eps
DB423354.eps
DB423355.eps
196.5
150
286
X
B
X
278
834
549
549
135 200
161.6
Y Z
Z
Mounting
For 185 mm busbars
DB423356.eps
185
Ø14.5
185
B-45
Dimensions and connection www.se.com
FuPacT ISFL1250
Dimensions and mounting
DB423358.eps
[a] (a)
DB423357.eps
DB423359.eps
303
435
X X X
B 850
250 645
211.5
[b] (b)
223
Y
18 100
150 Y
190 [a] S
ide cover for front
panel cut-out.
Z [b] Terminal shields.
B-46
www.se.com
Dimensions and connection
FuPacT ISFL1250
Connection and accessories
Connection
Connection via lugs/flexible bars Connection via connectors
X X X X
DB423360.eps
DB423361.eps
DB423362.eps
DB423363.eps
290 290
340 340
B
17 24 64.7 24
20
44.2 48 118.7 48
74
98.2
Z Y Z Y
Current transformer
DB423365.eps
DB423364.eps
X X
63
20 60
30
Y
Z
B-47
Wiring diagrams www.se.com
FuPacT ISFL
Power
DB423475.eps
FU01 FU02 FU03
Auxiliary contacts
B ISFL160 ISFL250 to 630
DB423476.eps
DB423477.eps
ISFL1250
DB423478.eps
Blown fuse
ISFL160 to 1250 fuse monitor
DB423479.eps
22
21
14
13
B-48
www.schneider-electric.com
FuPacT GS
Presentation
Offer panorama.........................................................................C-2
FuPacT GS 32 A............................................................................... C-2
FuPacT GS 50/63 A.......................................................................... C-3
FuPacT GS 100-160 A..................................................................... C-4
FuPacT GS 200/400 A..................................................................... C-5
FuPacT GS 630/800 A..................................................................... C-6
FuPacT GS 1250 A........................................................................... C-7
Characteristics
IEC switch-disconnector-fuses
for use with NFC or DIN fuses.............................................C-8
IEC switch-disconnector-fuses
for use with BS fuses........................................................... C-12
Detailled presentation
C
Presentation of the FuPacT GS range.......................... C-16
FuPacT GSB and GSC 32............................................................. C-16
FuPacT GSC 50, GSB and GSD 63.............................................. C-18
FuPacT GSB 100, GSC and GSD 125, GSB and GSD 160......... C-20
FuPacT GSB 200, GSB and GSD 250, GSB and GSD 400.......... C-22
FuPacT GSB and GSD 630, GSB and GSD 800.......................... C-24
FuPacT GSB and GSD 1250......................................................... C-26
FuPacT GSB and GSD 1250......................................................... C-27
Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT ISFL............................................................................................... B-1
Catalog numbers........................................................................................D-1
C-1
Presentation www.se.com
Offer panorama
FuPacT GS 32 A
DB436384.ai
A1 B
N
O
O
OFF
N
O
O
OFF
N
O
A2
O
OFF
C
ON
G
OFF
I
ON
OFF
F E D ON
I
OFF
ON
OFF
I
ON
OFF
C-2
www.se.com
Presentation
Offer panorama
FuPacT GS 50/63 A
DB436385.ai
A1 B C D
N
O
O
OFF
N
O
O
OFF
E
N
O
A2
C
O
OFF
A3
H ON
I G ON
I
OFF
OFF
I
ON
OFF
C-3
Presentation www.se.com
Offer panorama
FuPacT GS 100-160 A
DB436386.ai
B D E F
N
O
O
OFF
N
O
C
O
OFF
A
N
O
O
OFF
C
I H
I I
ON ON
OFF
OFF
O
O
I
ON
OFF
C-4
www.se.com
Presentation
Offer panorama
FuPacT GS 200/400 A
DB436387.ai
B D E F
N
O
O
OFF
N
O
C
O
OFF
A
N
O
O
OFF
C
I
ON
I H
I
ON
OFF
O
OFF
I
ON
OFF
C-5
Presentation www.se.com
Offer panorama
FuPacT GS 630/800 A
DB436388.ai
B C D
N
O
O
OFF
N
O
O
OFF
A
N
O
O
OFF
C
E
I
ON
OFF
H G F
I
ON
OFF
I
ON
OFF
C-6
www.se.com
Presentation
Offer panorama
FuPacT GS 1250 A
DB436389.ai
B C D
N
O
O
OFF
N
O
O
OFF
A
N
O
O
OFF
E C
O
OFF
ON
H G F
OFF
O
ON
OFF
O
ON
C-7
Characteristics www.se.com
IEC switch-disconnector-fuses
for use with NFC or DIN fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSC32 GSC50 GSD63
Environment
Conforming to standards Switch-disconnector-fuses IEC 60947-3
Fuses IEC60269/NFC63320 & IEC60269/BS88
Product certifications IEC and CCC
Degree of protection On Front panel, with terminal covers IP 20
conforming to IEC 60529
Ambient air temperature Storage °C -50 …+85
around the device Operation °C -20…+70
Flame resistance Body °C 960
conforming to Fuse cover °C – 850
IEC 60695-2-1
Pole characteristics following IEC 60947-1 / IEC 60947-3 et EN 60947-1 / EN 60947-3
Number of poles / Number 3 poles / 3 fuses b b b
of fuses 3 poles / Neutral switched NOT Protected b – –
4 poles / 4 fuses – b b
Type of fuses Fuse size 10x38 14x51 NH 000
C Conventional thermal
current
At ambient temperature (Ith) at 35°C A 32 50 63
Maximum admissible power W 2.9 4.6 6.0
dissipated by the fuse
Maximum power dissipated by a pole W 1.2 4.6 4.4
Derating in the open air or in at 40°C A 30 48 60
cubicle at 50°C A 27 43 54
at 60°C A 24 37 47
at 70°C A 20 31 39
Rated insulation voltage (Ui) 50/60 Hz V 800 800 800
Rated impulse withstand voltage (Uimp) kV 8 8 8
Rated operating voltage - AC (Ue) 50/60 Hz V 690 690 690
Rated operating voltage - AC 20 (Ue) V 800 800 800
Rated operational current Cat. AC-22A/B [1] 220/240 V A 32 50 63
at 50/60 Hz 380/415 V A 32 50 63
660/690 V A 32 50 63
Rated operational current Cat. AC-23A/B [1] 220/240 V A 32 50 63
at 50/60 Hz 380/415 V A 32 50 63
660/690 V A 32 50 63
Rated operational power Cat. AC-23A/B [1] 380/415 V kW 15 25 30
660/690 V kW 25 45 55
Breaking capacity with fuses (Iq) 400 V kA rms – – –
415 V kA rms 100 100 100
500 V kA rms – – –
690 V kA rms 100 100 100
Mechanical durability in cycle 0/C 10000 10000 10000
Durability in cycle 0/F Category Category A
Mechanical in cycle 0/C 8500 8500 8500
Electrical AC22A 415 V 1500 1500 1500
AC22A 690 V 1500 1500 1500
AC23A 415 V 1500 1500 1500
AC23A 690 V 1500 1500 1500
Sectioning ability Yes Yes Yes
Fully apparent cut No No No
Degree of pollution III III III
[1] Category "A": frequent operating cycles, category "B": infrequent operating cycles.
C-8
www.se.com
Characteristics
IEC 60947-3
IEC60269/NFC63320 & IEC60269/BS88
IEC and CCC
IP 20
-50 …+85
-20…+70
960
850
b b b b b b b b
– – – – – – – –
b b b b b b b b
22x58 NH 00 NH 00 NH 1 NH 2 NH 3 NH 3 NH 4
C-9
Characteristics www.se.com
IEC switch-disconnector-fuses
for use with NFC or DIN fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSC32 GSC50 GSD63
Control auxiliaries
Directe front rotary handle b b b
Front extended handle b b b
Laterale extend handle b b b
Padlocking b b b
Signaling auxiliaries
Auxiliary contact with pre-cut information b b b
Test position b b b
Installation and connection accessories
Internal neutral link – b b
GS1 AM110 and GS1 AM101 early break and signaling contact characteristics
Conventional thermal current (Ith) for ambient temperature y 40 °C A 10
Rated operational current (Ie) Cat. AC-15 A 120 V: 6 - 240 V: 3 - 400 V: 1.8 - 480 V: 1.5
Cat. DC-13 A 24 V: 2.8 - 48 V: 1.4 - 125 V: 0.55 - 250 V: 0.27 - 400 V: 0.15
C-10
www.se.com
Characteristics
b b b b b b b b
– – – – – b b b
Tinned copper
b b b b b – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b – – –
b b b b b b b b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
C
b b b b b – – –
148 x 162 x 116 148 x 162 x 116 148 x 162 x 116 234 x 195 x 146 252 x 205 x 149 364 x 300 x 250 364 x 300 x 250 442 x 300 x 289
184 x 162 x 116 184 x 162 x 116 184 x 162 x 116 294 x 195 x 146 318 x 205 x 149 458 x 300 x 250 458 x 300 x 250 562 x 300 x 289
1.5 1.5 1.8 3.2 4.8 16.0 17.0 25.0
2.0 2.0 2.3 4.5 6.1 20.0 21.5 30.0
8.7 8.7 9.7 13 17 56 56.7 62
C-11
Characteristics www.se.com
IEC switch-disconnector-fuses
for use with BS fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSB32 GSB63 GSB100
Environment
Conforming to standards Switch-disconnector-fuses IEC 60947-3
Fuses IEC60269/NFC63320 & IEC60269/BS88
Product certifications IEC and CCC
Degree of protection On Front panel, with terminal covers IP 20
conforming to IEC 60529
Ambient air temperature Storage °C -50 …+85
around the device Operation °C -20…+70
Flame resistance Body °C 960
conforming to Fuse cover °C – 850
IEC 60695-2-1
Pole characteristics following IEC 60947-1 / IEC 60947-3 et EN 60947-1 / EN 60947-3
Number of poles / Number 3 poles / 3 fuses b b b
of fuses 3 poles / Neutral switched NOT Protected b – –
4 poles / 4 fuses – b b
Type of fuses Fuse size A1 A2–A3 A4
C Conventional thermal
current
At ambient temperature (Ith) at 35°C A 32 63 100
Maximum admissible power W 2.9 3.8 8.4
dissipated by the fuse
Maximum power dissipated by a pole W 1.2 4.4 3.7
Derating in the open air or in at 40°C A 30 60 95
cubicle at 50°C A 27 54 85
at 60°C A 24 47 74
at 70°C A 20 39 62
Rated insulation voltage (Ui) 50/60 Hz V 800 800 800
Rated impulse withstand voltage (Uimp) kV 8 8 8
Rated operating voltage - AC (Ue) 50/60 Hz V 690 690 690
Rated operating voltage - AC 20 (Ue) V 800 800 800
Rated operational current Cat. AC-22A/B [1] 220/240 V A 32 63 100
at 50/60 Hz 380/415 V A 32 63 100
660/690 V A 32 63 100
Rated operational current Cat. AC-23A/B [1] 220/240 V A 32 63 100
at 50/60 Hz 380/415 V A 32 63 100
660/690 V A 32 63 100
Rated operational power Cat. AC-23A/B [1] 380/415 V kW 15 30 51
660/690 V kW – 55 90
Breaking capacity with fuses (Iq) 400 V kA rms – – –
415 V kA rms 100 100 50
500 V kA rms – – –
690 V kA rms 80 100 50
Mechanical durability in cycle 0/C 10000 10000 10000
Durability in cycle 0/F Category Category A
Mechanical in cycle 0/C 8500 8500 8500
Electrical AC22A 415 V 1500 1500 1500
AC22A 690 V 1500 1500 1500
AC23A 415 V 1500 1500 1500
AC23A 690 V 1500 1500 1500
Sectioning ability Yes Yes Yes
Fully apparent cut No No No
Degree of pollution III III III
[1] Category "A": frequent operating cycles, category "B": infrequent operating cycles.
C-12
www.se.com
Characteristics
IEC 60947-3
IEC60269/NFC63320 & IEC60269/BS88
IEC and CCC
IP 20
-50 …+85
-20…+70
960
850
b b b b b b b
– – – – – – –
b b b b b b b
A4 B1–B2 B1…B3 B1…B4 C2 C3 D1
C-13
Characteristics www.se.com
IEC switch-disconnector-fuses
for use with BS fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSB32 GSB63 GSB100
GS1 AM110 and GS1 AM101 early break and signaling contact characteristics
Conventional thermal current (Ith) for ambient temperature y 40 °C A 10
Rated operational current (Ie) Cat. AC-15 A 120 V: 6 - 240 V: 3 - 400 V: 1.8 - 480 V: 1.5
Cat. DC-13 A 24 V: 2.8 - 48 V: 1.4 - 125 V: 0.55 - 250 V: 0.27 - 400 V: 0.15
C-14
www.se.com
Characteristics
b b b b b b b
– – – – b b b
Tinned copper
b b b b – – –
b b b b b b b
b b b b b b b
b b b b b b b
b b b b b b b
b b b b – – –
– – – – – – –
b
b
b
b
b
b
b
b
b
b
b
b
b
b C
b b b b – – –
190 x 162 x 136 234 x 195 x 146 234 x 195 x 146 252 x 205 x 149 364 x 300 x 250 364 x 300 x 250 442 x 300 x 289
240 x 162 x 136 294 x 195 x 146 294 x 195 x 146 318 x 205 x 149 458 x 300 x 250 458 x 300 x 250 562 x 300 x 289
2.3 3.2 3.2 4.8 16.0 17.0 25.0
2.3 4.5 4.5 6.1 20.0 21.5 30.0
9.7 13 13 17 56 56.7 62
C-15
Detailled presentation www.se.com
Functions
The FuPacT GSB32 and GSC32 switch disconnector fuses are used with fuses that
protect electrical circuits against overloading and short circuits.
DB436418.ai
DB436417.ai
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
C Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
DB436419.ai
DB436420.ai
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
The 4P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse and a neutral connection, cut-off, UNPROTECTED.
3 poles, 3 fuse-links 4 poles, 3 fuse-links
Controlling the devices
bb The devices can be controlled in three ways:
vv By direct control using reference GS1AH103. This control is fitted directly
DB436422.ai
DB436421.ai
to the device.
vv By extended frontal control with a handle installed on the door of the electrical
ON
OFF
cabinet.
vv By extended lateral control with a handle installed on the side of the electrical
cabinet.
Direct handle Extended front handles bb The control rods are available in 3 lengths: 200 , 320 or 400 m.
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered separately
vv For frontal installation, black or yellow/red with or without test position
DB436423.ai
The function whereby the devices can be locked in the OFF position is available on
DB436424.ai
ON
OFF
the direct control handle and the extended control handles.
It allows up to 3 padlocks to be fitted on each handle.
standard version:
DB436427.ai
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
disconnector fuse are the same as those of the standard version.
Extended front handles, Extended lateral handles,
red handle on yellow front red handle on yellow front
C-16
www.se.com Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB and GSC 32
DB436428.ai
Fuse type and installation
bb GSC 32 supports NF 10*38 cylindrical fuses compliant with IEC60269/NFC63320
DB436429.ai
standards.
C
DB425715.eps
bb GSB 32 supports BS A1 fuses compliant with IEC60269/BS88 standards.
Note: The fuses are not supplied with the devices.
bb For GSC 32, the fuses are installed in the cover, opened prior to installation.
NFC fuse BS fuse
bb For GSB 32, the fuses are installed in the device on the mountings provided for
this purpose. Manual tightening is strongly advised in order to comply with the
recommended tightening torques (consult the instruction sheet ).
DB436527.ai
DB436528.ai
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm
DB436430.ai
C-17
Detailled presentation www.se.com
DB436438.ai
DB436437.ai
Functions
The FuPacT GSC50, GSB63 and GSD63 switch disconnector fuses are used with
fuses that protect electrical circuits against overloading and short circuits.
FuPacT GSC 50 FuPacT GSD 63 They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
DB436439.ai
DB436440.ai
C Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
3 poles, 3 fuse-links 4 poles, 4 fuse-links
the fuse.
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral link (see internal neutral links).
DB436441.ai
device. This prevents the opening of the door cabinet if the device is in the ON
DB436447.ai
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
The function whereby the devices can be locked in the OFF position is available on
3 padlocks 3 padlocks the direct control handle and the extended control handles.
on direct handle on extended handle It allows up to 3 padlocks to be fitted on each handle.
It is also possible to padlock the devices directly, either on the control unit using a
single padlock or a multi-padlock lockout accessory or on the lockout tab located on
the lower face of the control unit. This can accommodate up to 3 padlocks.
DB436445.ai
DB436446.ai
bb yellow for the front face of the device or the control plate
DB436448.ai
DB436449.ai
ON
I
The performance characteristics of the FuPacT emergency cut-off switch
disconnector fuse are the same as those of the standard version.
OFF
DB436450.ai
Connecting the devices
The FuPacT GSC 50, GSD 63 and GSB 63 devices are fitted with screw terminals
which can accommodate conductors of:
bb 10 to 25 mm² for the GSC 50
bb 16 to 25 mm² for the GSD 63 and GSB 63.
DB436429.ai
DB436497.ai
bb GSC 50 supports NF 14*51 cylindrical fuses compliant with IEC60269/NFC63320
DB425715.eps
standards
bb GSD 63 supports DIN 000 fuses compliant with IEC60269/NFC63320 standards
bb GSB 63 supports BS A2 and A3 fuses compliant with IEC60269/BS88 standards
Note: The fuses are not supplied with the devices.
NFC fuse BS fuse DIN fuse C
bb For GSC 50 and GSD 63, the fuses are installed by rotating the transparent
protective cover, with the power supply switched off, then inserting the fuses in the
fuse holders.
DB436452.ai
DB436453.ai
bb For GSB 63, the fuses are installed by removing the transparent protective cover,
with the power supply switched off, then installing the fuses on the mounitng
provided for this purpose. Manual tightening is strongly advised in order to comply
with the recommended tightening torques (consult the device manual).
DB436456.ai
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled DIN link
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone
Reference LV481110 is a packet of 10 plastic tappets
C-19
Detailled presentation www.se.com
Functions
DB436458.ai
The FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160 switch disconnector
fuses are used with fuses that protect electrical circuits against overloading and
short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
DB436440.ai
The devices are installed on a plate. The mounting points are incorporated into the
Number of poles
3 poles, 3 fuse-links 4 poles, 4 fuse-links The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
<Sansliend'intersection>
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral links.
cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered
Extended front handles Extended lateral handles separately.
vv In the event of frontal installation, black or yellow/red, with or without test
position.
vv For lateral installation, black or yellow/red, without test position.
DB436462.ai
DB436463.ai
bb The front handles allow the door to be interlocked with the control rod of the
device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
DB436465.ai
It is also possible to padlock the devices directly, either on the control unit using a
single padlock or a multi-padlock lockout accessory or on the lockout tab located on
the lower face of the control unit. This can accommodate up to 3 padlocks.
DB436467.ai
fuse use special colors, as stipulated by the standards and different from those of the
standard version:
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
Extended front handles, Extended lateral handles,
disconnector fuse are the same as those of the standard version.
red handle on yellow front red handle on yellow front
C-20
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB 100, GSC and GSD 125, GSB and GSD 160
DB436468.ai
DB436469.ai
with tin-plated terminal to connect conductors fitted with cable lugs.
Connection accessories can be used to connect directly conductors without cable lugs.
The accessories are fitted to the terminal and accommodate the bare conductors.
bb FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160: GS1AW33 (set of 3)
or GS1AW34 (set of 4).
In order to protect the direct contact connections, terminal covers may be used.
bb For FuPacT GSB 100, GSC and GSD 125: GS1AP33 (set of 3) or GS1AP34
(set of 4).
bb For FuPacT GSD and GSB 160: GS1AP43 (set of 3) or GS1AP44 (set of 4).
DB436429.ai
standards.
DB436497.ai
C
DB425715.eps
bb GSD 125 and GSD 160 support DIN 00 fuses compliant with IEC60269/
NFC63320 standards.
bb GSB 160 support BS A4 fuses compliant with IEC60269/BS88 standards.
Note: The fuses are not supplied with the devices.
NFC fuse BS fuse DIN fuse
bb For all FuPacT GSC and GSD 125, GSD 160, the fuses are installed by rotating
the transparent protective cover, with the power supply switched off, then inserting
the fuses in the fuse holders.
DB436521.ai
DB436522.ai
bb For the FuPacT GSB 100, GSB 160, the fuses are installed by rotating the
transparent protective cover, with the power supply switched off, then installing the
fuses in the housings provided for this purpose. Manual tightening is strongly
advised in order to comply with the recommended tightening torques (consult the
device manual).
Cone guide
DB436456.ai
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.
indicated.
2 auxiliary contacts are fitted directly to the device (see manual) and 2 others can be
stacked on top of the first ones.
The NO or NC auxiliary contacts thus allow the ON, OFF and TEST positions of the
device to be indicated
The TEST position is indicated if a handle WITH TEST position is used
DB436471.ai
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.
C-21
Detailled presentation www.se.com
Functions
DB436472.ai
The FuPacT GSB 200, GSD and GSB 250, GSD and GSB 400 switch disconnector
fuses are used with fuses that protect electrical circuits against overloading and
short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
DB436440.ai
The devices are installed on a plate. The mounting points are incorporated into the
products. There is no need to add accessories to fasten the products to a plate.
C Number of poles
3 poles, 3 fuse-links 4 poles, 4 fuse-links The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
<Sansliend'intersection>
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral links.
cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered
Extended front handles Extended lateral handles separately.
vv In the event of frontal installation, black or yellow/red, with or without test
position.
vv For lateral installation, black or yellow/red, without test position.
DB436476.ai
bb The front handles allow the door to be interlocked with the control rod of the
DB436477.ai
device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
3 padlocks 3 padlocks The function whereby the devices can be locked in the OFF position is available on
on direct handle on extended handle the direct control handle and the extended control handles.
It allows up to 3 padlocks to be fitted on each handle.
It is also possible to padlock the devices directly, either on the control unit using a
DB436478.ai
DB436479.ai
DB436481.ai
standard version:
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
disconnector fuse are the same as those of the standard version.
Extended front handles, Extended lateral handles,
red handle on yellow front red handle on yellow front
C-22
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB 200, GSB and GSD 250, GSB and GSD 400
DB436482.ai
DB436483.ai
tin-plated terminal to connect conductors fitted with cable lugs.
Connection accessories can be used to connect directly conductors without cable lugs.
The accessories are fitted to the terminal and accommodate the bare conductors.
bb FuPacT GSB 200: GS1AW43 (set of 3) or GS1AW44 (set of 4).
bb FuPacT GSD and GSB 250: GS1AW43 (set of 3) or GS1AW44 (set of 4).
bb FuPacT GSD and GSB 400: LV481203 (set of 3) or LV481204 (set of 4).
In order to protect the direct contact connections, terminal covers may be used.
For FuPacT GSB 200, GSD and GSB 250, GSD and GSB 400:
bb GS1AP43 (set of 3)
bb GS1AP44 (set of 4)
DB436429.ai
bb GSD 250 supports DIN 1 fuses compliant with IEC60269/NFC63320 standards.
DB436497.ai
C
DB425715.eps
bb GSB 250 supports BS B1, B2 and B3 fuses compliant with IEC60269/BS88
standards.
bb GSD 400 supports DIN 2 fuses compliant with IEC60269/NFC63320 standards.
bb The GSB 400 support BS B1, B2, B3 and B4 fuses compliant with IEC60269/BS88
standards. NFC fuse BS fuse DIN fuse
Note: The fuses are not supplied with the devices.
bb For all FuPacT GSD 250 and GSD 400, the fuses are installed by rotating the
transparent protective cover, with the power supply switched off, then inserting the
DB436523.ai
fuses in the fuse holders.
DB436524.ai
bb For the FuPacT GSB 200, GSB 250 and GSB 400, the fuses are installed by
rotating the transparent protective cover, with the power supply switched off, then
installing the fuses in the housings provided for this purpose. Manual tightening is
strongly advised in order to comply with the recommended tightening torques
(consult the device manual).
They are installed directly on the left-hand side of the product on the 3-pole device.
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.
C-23
Detailled presentation www.se.com
Functions
DB436486.ai
The FuPacT GSD and GSB 630, GSD and GSB 800 switch disconnector fuses are
used with fuses that protect electrical circuits against overloading and short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
DB436419.ai
DB436440.ai
the fuse.
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral bar.
vv By extended lateral control with a handle installed on the side of the electrical
cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
Note: They must be ordered separately.
Extended front handles Extended lateral handles bb Several types of IP65 control handle are available and must be ordered separately
vv For frontal installation, black or yellow/red without test position.
vv For lateral installation, black or yellow/red without test position.
bb The front handles allow the door to be interlocked with the control rod of the
device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
DB436489.ai
The function whereby the devices can be locked in the OFF position is available on
the direct control handle and the extended control handles.
DB436490.ai
DB436492.ai
fuse use special colors, as stipulated by the standards and different from those of the
standard version:
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
Extended front handles, Extended lateral handles, disconnector fuse are the same as those of the standard version.
red handle on yellow front red handle on yellow front
C-24
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB and GSD 630, GSB and GSD 800
DB436493.ai
DB436495.ai
Connecting the devices
The FuPacT GSD and GSB 630, GSD and GSB 800 devices are fitted with tin-plated
terminal to connect directly conductors fitted with cable lugs or bars.
To facilitate rear connections, the connection terminal can be rotated.
In order to protect the direct contact connections, terminal covers may be used.
For FuPacT GSD and GSB 630, GSD and GSB 800:
bb GS2AP73 (set of 3)
bb GS2AP64 (set of 4).
DB436497.ai
DB436496.ai
bb GSB 630 and GSB 800 supports BS C2 and C3 fuses respectively compliant with
IEC60269/BS88 standards.
Note: The fuses are not supplied with the devices.
bb For FuPacT GSD 630 and 800, the fuses are installed by rotating the transparent
protective cover, with the power supply switched off, then inserting the fuses in the
BS fuse DIN fuse
C
fuse holders.
bb For FuPacT GSB 630 and GSB 800, the fuses are installed by rotating the
transparent protective cover, with the power supply switched off, then installing the
DB436525.ai
DB436526.ai
fuses in the housings provided for this purpose. Manual tightening is strongly
advised in order to comply with the recommended tightening torques (consult the
device manual).
DB436502.ai
They are installed directly on the left-hand side of the product on the 3-pole device.
DB436456.ai
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.
FuPacT GSD and GSB 630, GSD and GSB 800 devices can be fitted with 8
auxiliary contacts enabling the mechanical position of the device to be indicated.
DB436430.ai
4 auxiliary contacts are fitted directly to the device (see manual) and 4 others can
be stacked on top of the first ones.
The NO or NC auxiliary contacts thus allow the ON and OFF positions of the
device to be indicated.
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon
as the handle is activated but before the poles are opened.
DB436503.ai
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.
C-25
Detailled presentation www.se.com
Functions
DB436504.ai
The FuPacT GSD and GSB 1250 A switch disconnector fuses are used with fuses
that protect electrical circuits against overloading and short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
DB436440.ai
the fuse. One of the poles may be fitted with a neutral bar.
O
OFF
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered separately
ON
padlocking lug accessible on the front panel of the control unit. This lug can
ON
accommodate up to 3 padlocks.
3 padlocks 3 padlocks directly
Using the devices as emergency switch disconnector fuse
on extended handle on the device
The FuPacT switch disconnectors fuse can be used as emergency cut-off devices.
For this application, they must be easily visible, accessible and identifiable (see
standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
DB436509.ai
DB436510.ai
For the purposes of easy identification, the emergency cut-off switch disconnector
O
OFF
fuse use special colors, as stipulated by the standards and different from those of the
standard version:
ON
bb yellow for the front face of the device or the control plate
bb red for the handle.
Extended front handles, Extended lateral handles, The performance characteristics of the FuPacT emergency cut-off switch
red handle on yellow front red handle on yellow front disconnector fuse are the same as those of the standard version.
C-26
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB and GSD 1250
DB436513.ai
DB436511.ai
Connecting the devices
The FuPacT GSD and GSB 1250 A devices are fitted with tin-plated terminal to
connect directly conductors fitted with cable lugs or bars.
To facilitate rear connections, the connection terminal can be rotated.
In order to protect connections from direct contact, terminal covers may be used.
For FuPacT GSD and GSB 1250 A:
bb GS2AP83 (set of 3)
bb GS2AP84 (set of 4).
DB436514.ai
Note: The fuses are not supplied with the devices.
DB436516.ai
DB436517.ai
bb For FuPacT GSD 1250, the fuses are installed by rotating the transparent
protective cover, with the power supply switched off, then inserting the fuses in the
fuse holders. The fuse holder terminal must be tightened for correct installation of
the fuses
bb For FuPacT GSB 1250, the fuses are installed by rotating the transparent BS fuse DIN fuse
protective cover, with the power supply switched off, then installing the fuses in the
housings provided for this purpose. Manual tightening is strongly advised in order
to comply with the recommended tightening torques (consult the device manual).
DB436518.ai
which is NOT CUT (no mechanism).
They are installed directly on the left-hand side of the product on the 3-pole device.
DB436456.ai
DIN link
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
DB436430.ai
4 auxiliary contacts are fitted directly to the device (see manual) and 4 others can be
stacked on top of the first ones.
The NO or NC auxiliary contacts thus allow the ON and OFF positions of the device
to be indicated
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.
C-27
Dimensions and connection www.se.com
FuPacT GS 32 A
Dimensions
Dimensions
GSC 32 A with direct front handle GSB 32 A with direct front handle
112 96 112
44 15 44 96
DB436135.eps
DB436136.eps
DB436137.eps
19 6.5 5.2 35 19 6.5 5.2 15
14 14 14
45 X X 45 X X X
98 98
90°
65°
GSC 32 A with extended front handle GSB 32 A with extended front handle
45 102 min. [1] 45 102 min. [1] Ø78
C
DB436138.eps
DB436139.eps
65°
DB436140.eps
35 35
X X X
14 49 14 49 14
90°
70
Z Z Y
[1] W
ith 1 or 2 auxiliary contacts GS1 AM1pp: 130 mm.
With 3 or 4 auxiliary contacts GS1 AM1pp: 155 mm.
GSC 32 A with extended lateral handle GSB 32 A with extended lateral handle
96 36 min. 44 96 36 min. 44
Ø78
DB436141.eps
DB436142.eps
DB436143.eps
90°
X X X
52.5 52.5 70 19
Y Y Z
C-28
www.se.com
Dimensions and connection
FuPacT GS 32 A
Mounting and front panel cut-outs
Mounting
On the backplate On DIN rail
37.5
DB436144.eps
DB436145.eps
=
79.5 X 35 X
2 Ø5
Y Y
C
DB436146.eps
40
X
Ø37
4 Ø7
40 X
Ø37
19
Z
Accessories
Auxiliary contacts
[a]
DB436148.eps
49
88.5
112
Z
[c] 1 to 4 auxiliary contacts GS1 AM1pp.
C-29
Dimensions and connection www.se.com
FuPacT GS 50/63 A
Dimensions
Dimensions
Direct front handle
6.5
DB436149.eps
DB436150.eps
DB436151.eps
65°
142
X X X
118
90°
31 B 5.4
(3P)
A C 18 116
204 D (3P)
B
(4P)
D (4P)
Z Y Y
DB436153.eps
65°
X X
59
90°
70
Z Y
[1] FuPacT GS 50 A : 1 auxiliary contact GS1 AM1pp: E + 23.5 mm, 2 auxiliary contacts GS1 AM1pp: E + 47 mm.
DB436155.eps
230 max.
Ø78
90°
X X
70 31
Y Z
Type A B C D E min. F G H I
GSC 50 A 3P 87 31 45 121 100 27 110.5 134 31
4P 87 31 45 148 100 54 110.5 134 -
GSB/GSD 63 A 3P 116.5 36 50 136 139 32 108.5 132 36
4P 116.5 36 50 168 139 64 108.5 132 -
C-30
www.se.com
Dimensions and connection
FuPacT GS 50/63 A
Mounting and front panel cut-outs
Mounting
On the backplate On DIN rail
3 poles 4 poles
F C F C
4 Ø5 4 Ø5
DB436156.eps
DB436157.eps
= =
106 X 106 X 35 X
= =
Y Y Y
C
DB436158.eps
4 Ø7
40 X
Ø37
4 Ø7
40 X
Ø37
31
Z
Accessories
Auxiliary contacts External neutral module
[a]
DB436160.eps
DB436161.eps
X X
59
G I Y
H
Z
[c] 1 to 4 auxiliary contacts GS1 AM1pp.
Type A B C D E min. F G H I
GSC 50 A 3P 87 31 45 121 100 27 110.5 134 31
4P 87 31 45 148 100 54 110.5 134 -
GSB/GSD 63 A 3P 116.5 36 50 136 139 32 108.5 132 36
4P 116.5 36 50 168 139 64 108.5 132 -
C-31
Dimensions and connection www.se.com
FuPacT GS 100/160 A
Dimensions
Dimensions
Direct front handle
K K K
[a] (4P)
DB436162.eps
DB436164.eps
DB436163.eps
4Ø
65°
142
X H B J X X
90°
116
2.5 I C L
(3P)
31 C D E F
C A
(4P)
G (3P)
204 G (4P)
Z Y Y
[a] Terminal cover.
DB436166.eps
65°
X X
N 90°
125
Z Y
Ø78
90°
X X
125 31
Y Z
C-32
www.se.com
Dimensions and connection
FuPacT GS 100/160 A
Mounting and front panel cut-outs
Mounting
On the backplate
3 poles P E 4 poles P E
4Ø 4Ø
DB436169.eps
= =
O X O X
= =
Y Y
4 Ø7
40 X C
Ø37
4 Ø7
40 X
Ø37
31
Z
Accessories
Auxiliary contacts External neutral module
[b]
DB436172.eps
DB436173.eps
X X
108.5 Q Y
132 Z
[b] 1 to 4 auxiliary contacts GS1 AM1pp.
Type E O P Ø Q
GSB 100 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSC 125 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSD 125 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSD 160 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSB 160 A 3P 64 140 50 5 54
4P 64 140 100 5 -
C-33
Dimensions and connection www.se.com
FuPacT GS 200/400 A
Dimensions
Dimensions
Direct front handle
J J J
(4P)
DB436175.eps
DB436176.eps
[a]
DB436174.eps
4 Ø11
65°
142
X X X
F B I
90°
136
C
G H C K
(3P)
31 C 6.4 D 25
(4P)
A E (3P)
208 E (4P)
Z Y Y
[a] Terminal cover.
DB436178.eps
Ø78
65°
X X
M 90°
125
Z Y
Ø78
DB436179.eps
90°
X
125 31
Type A B C D E F G H I J K L min. M N O P
GSB 200 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 250 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 400 A 3P 149 205 70 91 252 355 3 20 175 66 50 157 102.5 172 66 70
4P 149 205 70 91 318 355 3 20 175 66 50 157 102.5 172 132 -
C-34
www.se.com
Dimensions and connection
FuPacT GS 200/400 A
Mounting and front panel cut-outs
Mounting
On the backplate
3 poles 4 poles
4 Ø6 O D O D
DB436181.eps
4 Ø6
= =
N X N X
= =
Y Y
C
DB436182.eps
DB436183.eps
4 Ø7
4 Ø7
40 X X
40
Ø37
Ø37
31
Z
Accessories
Auxiliary contacts External neutral module
[b]
DB436184.eps
DB436185.eps
X X
108.5 P
132 Z Y
[b] 1 to 8 auxiliary contacts GS1 AM1pp.
1 to 4 auxiliary contacts GS1 AM1pp with direct front handle.
Type A B C D E F G H I J K L min. M N O P
GSB 200 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 250 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 400 A 3P 149 205 70 91 252 355 3 20 175 66 50 157 102.5 172 66 70
4P 149 205 70 91 318 355 3 20 175 66 50 157 102.5 172 132 -
C-35
Dimensions and connection www.se.com
FuPacT GS 630/800 A
Dimensions
Dimensions
GSB 630 A / GSD 630 A / GSB 800 A / GSD 800 A
3 poles 94 94 4 poles 94 94 94
DB436186.eps
DB436188.eps
DB436187.eps
[a]
6 Ø13 8 Ø13
[b]
=
7
300 300
90 471 X X X
260 260
7
=
7 51 35 51 35
59
364 458
C 250
79.5
Z Y Y
[a] Terminal cover.
[b] Rear access connector plates.
Extended front handle
61 265 min.
DB436189.eps
DB436190.eps
Ø78 65°
22
X X
22
90°
150
210
Z Y
Ø78
90°
X X
210 79.5
Y Z
C-36
www.se.com
Dimensions and connection
FuPacT GS 630/800 A
Mounting and front panel cut-outs
Mounting
On the backplate
3 poles 284 34 4 poles 378 34
DB436193.eps
11 9 11 9
= =
X X
250 250
= =
Y Y
C
DB436194.eps
Ø37 4 Ø7
40
22 X
28
4 Ø7
40 X
Ø37
79.5
Accessories
Auxiliary contacts External neutral module
[c]
DB436197.eps
DB436196.eps
X X
150
166.5 106 Y
190 Z
[c] 1 to 8 auxiliary contacts GS1 AM1pp.
C-37
Dimensions and connection www.se.com
FuPacT GS 1250 A
Dimensions
Dimensions
GSB 1250 A / GSD 1250 A
3 poles 4 poles
120 120 120 120 120
DB436198.eps
DB436199.eps
DB436200.eps
[a]
[b]
12 Ø13 16 Ø13
=
7
300
90 471 X X X
260
7
=
7 25 77 25 77
C 59
79.5
40
442
35 40
562
35
289
Z Y Y
[a] Terminal cover.
[b] Rear access connector plates.
Extended front handle
61 304 min.
DB436201.eps
DB436202.eps
Ø78 90°
22
X X
22
150
= =
Z 300
Y
DB436204.eps
Ø78
90°
X X
210 79.5
Y Z
C-38
www.se.com
Dimensions and connection
FuPacT GS 1250 A
Mounting and front panel cut-outs
Mounting
On the backplate
3 poles 362 34 4 poles 482 34
DB436205.eps
11 9 11 9
= =
X X
250 250
= =
Y Y
C
DB436206.eps
4 Ø7
Ø37
40
X
22
28
4 Ø7
40 X
Ø37
79.5
Accessories
Auxiliary contacts External neutral module
[c]
DB436208.eps
DB436209.eps
X X
150
166.5 132 Y
190 Z
[c] 1 to 8 auxiliary contacts GS1 AM1pp.
C-39
Dimensions and connection www.se.com
FuPacT GS 32 to 1250 A
Class II installation
Minimun Air distance to respect between the protective screen and the plastic covers of
fuses in a Class II installation
GS 32 A
Reference L min.
LV481503 35
DB436542.ai
LV481504
LV481603
LV481604
C Reference
LV481513
L min.
40
DB436543.ai
LV481514
LV481403
LV481404
LV481613
LV481614
LV481623 35
LV481624
LV481413
LV481414
L LV481523
LV481524
LV481633
LV481634
LV481423
LV481424
LV481644
LV481653
LV481654
LV481663
LV481664
LV481433
LV481434
LV481443
LV481444
LV481454
LV481463
LV481464
LV481673
LV481674
LV481683
LV481684
LV481693
LV481694
LV481473
LV481474
L
C-40
www.se.com
Catalog numbers
ISFT100N.....................................................................................D-2
Devices and accessories................................................................. D-2
ISFT100........................................................................................D-3
Devices and accessories................................................................. D-3
ISFT160........................................................................................D-4
Devices and accessories................................................................. D-4
ISFT250 to ISFT630.................................................................D-5
Devices and accessories................................................................. D-5
ISFL160........................................................................................D-6
Devices and accessories................................................................. D-6
ISFL250 to ISFL1250...............................................................D-8
Devices and accessories................................................................. D-8
Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
D-1
Catalog numbers
ISFT100N
Devices and accessories
Accessories
DIN rail fixing kit LV480753
DB120643.eps
Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480755
DB120652.eps
D-2
Catalog numbers
ISFT100
Devices and accessories
Accessories
Mounting accessories
Accessory for mounting on a DIN rail 49877
DB401325.eps
Connection accessories
Distribution connector 3 x 16 mm2 Set of 3 49860
D
DB401327.eps
Electrical auxiliaries
Auxiliary changeover contact NO + NC 49885
DB414827.eps
D-3
Catalog numbers
ISFT160
Devices and accessories
Accessories
Mounting accessories
Handle with electronic fuse monitor LV480810
DB425779.eps
D
Terminal shields LV480819
DB425780.eps
Connection accessories
Incoming connector LV480818
DB425785.eps
Pressure plate with contact prism for multiple-use terminal with Cu/Alu conductors LV480816
DB425782.eps
from 6 to 70 mm²
Electrical auxiliaries
Auxiliary changeover contact NO+NC LV480755
DB425100.eps
D-4
Catalog numbers
ISFT250 to ISFT630
Devices and accessories
Accessories
Mounting accessories
Handle with electronic fuse monitor ISFT250 LV480821
DB425786.eps
ISFT400 LV480825
ISFT630 LV480828
Connection accessories
Pressure plate with contact from 70 to 150 mm2 ISFT250 LV480822
DB425788.eps
ISFT400 LV480827
ISFT630 LV480831
Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480833
DB425791.eps
D-5
Catalog numbers
ISFL160
Devices and accessories
Accessories
Sideframe door cut out - 850 mm LV480868
Sidewise angle bracket for side frame (x4) LV480869
DB401238.eps
DB401239.eps
D-6
Catalog numbers
ISFL160
Devices and accessories
Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480873
DB401245.eps
D-7
Catalog numbers
ISFL250 to ISFL1250
Devices and accessories
D ISFL630
ISFL1250
LV480858
LV480875
DB401247.eps
D-8
Catalog numbers
ISFL250 to ISFL1250
Devices and accessories
Accessories
Sideframe door cut out - 850 mm LV480868
Sidewise angle bracket for side frame Set of 4 LV480869
DB401238.eps
DB401239.eps
Db105281.eps
D
DB421666.eps
Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480874
DB401278.eps
D-9
Catalog numbers www.se.com
DB436420.ai
DB436419.ai
GSC32 / NFC LV481503 LV481504
(10 x 38), 32 A
DB436419.ai
DB436440.ai
GSC50 / NFC LV481513 LV481514
(14 x 51), 50 A
GSC125 / NFC LV481523 LV481524
(22 x 58), 125 A
ON
D
OFF
Lateral handle
32 and 50 A 125 A
Lateral Black Handle GS2AH210 GS2AH230
Lateral Red/Yellow Handle GS2AH220 GS2AH240
DB436398.ai
Accessories
Shaft
32 and 50 A 125 A
200 mm shaft GS2AE82 GS2AE22
DB436399.ai
Guide cone
32 to 1250 A
GS2AEH12
DB436400.ai
Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.
D-10
www.se.com
Catalog numbers
GSC32 - GSC50 - GSC125
Accessories
x10
Set of 10 accessories for auxiliary contact LV481110
D
DB436404.ai
Cable connectors
3P (set of 3) 4P (set of 4)
For GSC125 GS1AW33 GS1AW34
DB436405.ai
Terminal shield
3P (set of 3) 4P (set of 4)
For GSC125 GS1AP33 GS1AP34
DB436406.ai
Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.
D-11
Catalog numbers www.se.com
GSD 63 to 1250
Devices
DB436419.ai
DB436440.ai
GSD63/DIN 000 LV481403 LV481404
63 A
GSD125/DIN 00 LV481413 LV481414
125 A
GSD160/DIN 00 LV481423 LV481424
160 A
GSD250/DIN 1 LV481433 LV481434
250 A
GSD400/DIN 2 LV481443 LV481444
400 A
+ test position
Front Red/Yellow Handle GS2AHT520 GS2AHT540 - -
+ test position
Lateral handle
63 A 125 to 400 A 630 to 1250 A
Lateral Black Handle GS2AH210 GS2AH230 GS2AH250
Lateral Red/Yellow Handle GS2AH220 GS2AH240 GS2AH260
DB436413.ai
Accessories
Shaft
63 to 400 A 630 to 1250 A
200 mm shaft GS2AE22 GS2AE52
DB436399.ai
Guide cone
63 to 1250A
GS2AEH12
DB436400.ai
Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.
D-12
www.se.com
Catalog numbers
GSD 63 to 1250
Accessories
x10
Set of 10 accessories for auxiliary contact LV481110
D
DB436404.ai
Cable connectors
3P (set of 3) 4P (set of 4)
DB436405.ai
Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.
D-13
Catalog numbers www.se.com
GSB 32 to 1250
Devices
GSB32 - GSB63 - GSB100 - GSB160 - GSB200 - GSB250 - GSB400 - GSB630 - GSB800 - GSB1250
Basic Device : Front or lateral control
Switch/Type of fuse 3P/3F 4P/3F+N
DB436416.ai
DB436420.ai
DB436419.ai
GSB32 - BS A1 LV481603 LV481604
32A
DB436419.ai
DB436440.ai
GSB63 - BS A2/A3 LV481613 LV481614
63A
GSB100 - BS A4 LV481623 LV481624
100A
GSB160 - BS A4 LV481633 LV481634
160A
GSB200 - BS B1/B2 LV481643 LV481644
200A
GSB250 - BS B1/B2/B3 LV481653 LV481654
250A
GSB400 - BS B1/B2/B3/B4 LV481663 LV481664
400A
+ test position
Front Red/Yellow Handle GS2AHT520 GS2AHT540 - -
+ test position
Lateral handle
63 A 125 to 400 A 630 to 1250 A
Lateral Black Handle GS2AH210 GS2AH230 GS2AH250
DB436413.ai
Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.
D-14
www.se.com
Catalog numbers
GSB 32 to 1250
Accessories
Accessories
Shaft
32 A 63 to 400 A 630 to 1250 A
200 mm shaft GS2AE82 GS2AE22 GS2AE52
DB436399.ai
Guide cone
63 to 1250A
GS2AEH12
DB436400.ai
Accessories - GSB32 - GSB63 - GSB100 - GSB160 - GSB200 - GSB250 - GSB400 - GSB630 - GSB800 - GSB1250
Connection
External neutral module For GSB63 LV481901
For GSB100 LV481902
DB436414.ai
Cable connectors
3P (set of 3) 4P (set of 4)
DB436405.ai
Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.
D-15
Catalog numbers www.se.com
40 10 DF2EA40 0.020
50 10 DF2EA50 0.020
Cylindrical a 690 20 10 DF2FA20 0.045
22 x 58 25 10 DF2FA25 0.045
DF2 EAppp 32 10 DF2FA32 0.045
40 10 DF2FA40 0.045
50 10 DF2FA50 0.045
63 10 DF2FA63 0.045
80 10 DF2FA80 0.045
DB425716.eps
DF2 FApp
DF2 JApppp
D-16
www.se.com
Catalog numbers
FuPacT protection components
Cartridge fuses type gG
For protection of circuits without significant current peaks
Fuse Maximum Rating Set of Fuses without striker
type rated voltage Unit reference Weight
V A kg
DB425714.eps
40 10 DF2EN40 0.020
50 10 DF2EN50 0.020
Cylindrical a 690 20 10 DF2FN20 0.045
22 x 58 25 10 DF2FN25 0.045
DF2 ENpp 32 10 DF2FN32 0.045
40 10 DF2FN40 0.045
50 10 DF2FN50 0.045
63 10 DF2FN63 0.045
80 10 DF2FN80 0.045
DB425716.eps
DF2 FNpp
80 3 DF2GN1081 0.230
100 3 DF2GN1101 0.230
125 3 DF2GN1121 0.230
160 3 DF2GN1161 0.230
a 500 125 3 - -
DF4 GNpppp 160 3 - -
Blade a 690 160 1 DF2HN1161 0.400
NH 1 200 1 DF2HN1201 0.400
a 500 250 3 DF2HN1251 0.400
Blade a 690 250 3 DF2JN1251 0.560
NH 2 315 3 DF2JN1311 0.560
DB425719.eps
DF2 JNpppp
D-17
Catalog numbers www.se.com
D-18
Schneider Electric Industries SAS
10/2020
© 2020 - Schneider Electric. All Rights Reserved.
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Document reference: LVPED216031EN