Nothing Special   »   [go: up one dir, main page]

Fupact: Catalog 2020

Download as pdf or txt
Download as pdf or txt
You are on page 1of 170

FuPact

Catalog 2020
Fusegear range from 32 to 1250 A

schneider-electric.com
se.com
Green Premium
TM

An industry leading portfolio of offers delivering sustainable value

The Green Premium program stands for our commitment to deliver


customer valued sustainable performance. It has been upgraded
with recognized environmental claims and extended to cover all
offers including Products, Services and Solutions.
CO2 and P&L impact through… Resource Performance
Green Premium brings improved resource efficiency throughout an asset’s
More than 75% of our product lifecycle. This includes efficient use of energy and natural resources, along
sales offer superior transparency with the minimization of CO2 emissions.
on the material content, regulatory
information and environmental Cost of ownership optimization through… Circular Performance
impact of our products: We’re helping our customers optimize the total cost of ownership of their
assets. To do this, we provide IoT-enabled solutions, as well as upgrade,
• RoHS compliance repair, retrofit, and remanufacture services.
• REACh substance information
• Industry leading # of PEP’s* Peace of mind through… Well-being Performance
• Circularity instructions Green Premium products are RoHS and REACh compliant. We’re going
beyond regulatory compliance with step-by-step substitution of certain
materials and substances from our products.

Improved sales through… Differentiation


Green Premium delivers strong value propositions through third-party
labels and services. By collaborating with third-party organizations we can
support our customers in meeting their sustainability goals such as green
building certifications.

Discover what we
mean by green
Check your products!
*PEP: Product Environmental Profile (i.e. Environmental Product Declaration)
www.se.com FuPacT | 1

An alternative approach
to electrical
protection
2 | FuPacT www.se.com

The essentials of electrical protection


Schneider Electric is committed to bringing you one of the most flexible and comprehensive
fuse device offer on the market. We bring you essential functions combined with advanced
features such as measurement and turnable hooks to deliver a “best in class” solution that
provides electrical protection for your industrial applications with single and double breaking
switch fuses.

Fuse devices are designed to perform three functions for electrical protection:
• Switch function for circuit on-load control
• Fuse function against short-circuits and overloads
• Isolation from the power circuit.

A complete solution Simple and flexible Fully compatible Fully certified


Schneider Electric • Easy to install and Fusegear solutions Fuse offer complies
offers complete flexible in terms have been designed with international
electrical protection of footprint, cable to be used with standards,
for distribution connections, and all fuse-links and certifications
systems including product position. complying with and markings:
fuse devices that Includes mounting standard: • IEC 60947-1 and -3
fully integrate in plates or can be • IEC 60269-1 and -2 • CCC certificates
Schneider’s functional mounted directly onto • EAC certificates
enclosures (Prisma) busbars or DIN rail.
and busbar trunking • Easy to operate and
systems (Canalis) simple to maintain

Single breaking offer:


Fuse switch disconnectors
Functions:
• Short-circuit and overload protection
• Isolation
• On-load switching of circuits

• High level of reliability against short-circuits


FuPacT ISFT
• High flexibility on busbar systems thanks to its turnable hooks
100 to 630 A
FuPacT ISFL • Opening and closing operations are dependent on the operator’s
160 to 1250 A action
www.se.com FuPacT | 3

Components that work great together by design


All Schneider Electric components, from electrical devices and busbars, to splitter blocks
and switchboards, work together for optimal performance. Their electrical and mechanical
functions and communications features integrate seamlessly.

Our range of fuse devices provides:


• Protection for people and property
• Energy quality and availability
• Performance and high uptime
• Easy operation, thanks to standard operating process and simple maintenance.

Combine efficiency and intelligent control thanks to the fuse monitor


Available for the ISFL and ISFT FuPacT ranges, the fuse monitor is more than just an accessory.
Its protection and monitoring functions makes it indispensable:
• A monitor solution for the range
• Automatic reset of the fuse monitor once blown fuse is replaced
• Auxiliary contacts for different functions: alarm, tripping of a remote device
• No need of striker fuses, leading to a significant cost reduction

Double breaking offer:


Switch disconnector fuses
Functions:
• Short-circuit and overload protection
• Isolation
• On-load switching of circuits

• High level of protection thanks to upstream and downstream


double breaking
FuPacT GS • Fast opening and closing
32 to 1250 A • Opening and closing operations occur independently of the
operator’s action
4 | FuPacT www.se.com

SINGLE BREAKING FUSE SOLUTIONS


Single Breaking
FuPacT ISFT - FUSE SWITCH DISCONNECTORS

FuPacT ISFT devices


FuPacT ISFT helps you remain competitive in today’s market. Its features offer
more flexibility in terms of mounting and cabling.
FuPacT ISFT is also the smallest product of the market at just 53 mm width for
The smallest
NH 000 fuse-links (100 A).
product on
the market
Fuse switch disconnectors can be mounted and fixed effortlessly!
ISFT 100N (100 A)
•L ess stock: FuPacT ISFT range includes turnable hooks to enable downstream or upstream
distribution with the same product.
• Save time: less assembling steps. The product can be fixed very quickly for a faster mounting.
• Enhanced safety: the product offers optimized user protection against arc flash.

Snap-on busbar cover


• Avoid any risk of coming into contact
with busbars

Turnable hooks Less space needed


• Allows top or bottom cable outlet (53 mm width instead of
• Faster and flexible mounting on the busbar standardized 106 mm)
• Adapted to 60 mm busbar systems

FuPacT ISFT and


ISFL combine
efficiency and
intelligent control
Designed for secondary switchboards and reduce costs:

The fuse monitor


provides:
•P
 recise location
and fast correction
of short-circuit and
overload faults
•N
 o need of striker-
type fuses
•A
 uxiliary contacts for
different functions:
alarm, tripping of a
Integrated and extended hand protection remote device, etc.
• Prevents fuse-link contact •A
 utomatic reset of
• Protection against electric arcs the fuse monitor
after blown fuse is
Device locking replaced
• Devices can be sealed and locked

Slidable windows
• Enabling independent testing of individual fuse-links
www.se.com FuPacT | 5

SINGLE BREAKING FUSE SOLUTIONS


Single Breaking
FuPacT ISFL - FUSE SWITCH DISCONNECTORS

More flexibility with FuPacT ISFL


FuPacT ISFL is one of the most efficient vertical fuse switch disconnectors ever designed with
a compact form and a modular system.
Thanks to its size, FuPacT ISFL doesn't require extra space for current transformer installation.
Its interface is standardized for all types of measurement devices.

Measuring device
• Energy consumption control is feasible by
the easy installation of a measuring device

Easy to hook
• Turnable contact hooks available for FuPacT ISFL
160 A 3-pole (60 mm busbars)
• Fast mounting with reduced manual operations
• Adapted to all busbar systems: 60/100/185 mm,
present in main switchboards

Designed for main switchboards

Fuse monitor
• Precise location and fast correction of
short-circuit and overload faults

• Fast connection with variable box terminals

FuPacT ISFL is available in two different versions


• 1-pole switchable dedicated to 185 mm busbars
• 3-pole switchable available for 60/100/185 mm busbars

Same lenght and depth


for size 00 (160 A)
to size 3 (630 A)
6 | FuPacT www.se.com

DOUBLE BREAKING FUSE SOLUTIONS


Double Breaking
FuPacT GS - SWITCH DISCONNECTOR FUSES

High performance thanks to 


FuPacT GS
FuPacT GS offer provides protection for personnel thanks to its double isolation, upstream and
downstream when the switch is open.
It also provides high system availability in buildings, infrastructure and even in industrial plants.
It is compatible with fuse-links BS, NFC and NH.

3 ways to command FuPacT GS:


front and lateral extended handle for all ratings
and direct handle from 32 to 400 A
Commun auxiliary contacts
from 32 to 1250 A
and auxiliary contacts
with pre-cut function

Transparent fuse covers


for an easy reading of the fuse type • Front extended handle

• Direct extended handle

Handle with 3 positions


ON, OFF, TEST

External neutral module


for direct neutral, not switch,
in the same form factor as poles • Lateral handle

Improve your power distribution with Power and control your industrial
FuPacT GS motors with FuPacT GS
• Distribution switchboards. • Motor starters: DOL, Star-Delta, softstarters.
• Disconnection, isolation, locking and primary control • Variable speed starters with frequency converters.
of incoming circuits. • Machine types: HVAC units, industrial cranes, hoists.
• Categories AC21/AC22 for electrical distribution, • Industries: paper, steel, ports, automotive, power, mining,
AC23 for motor feeders. rail, oil & gas.
www.se.com FuPacT | 7

Fuse-link offer

Schneider Electric provides a fuse-link offer with NH fuses to a complete solution for our
customers.

We offer fuse-links with different curves, available without strikers:

• Fuse-links type aM
Protection of equipment with current peaks like motor
applications.

• Fuse-links type gG
Protection of circuits without significant electrical
distribution current peaks.
8 | FuPacT www.se.com

Functional installation
in Prisma product range

Easy implementation
FuPacT fusegear can be installed on mounting plates or mounted directly on
the busbar from 60 to 185 mm.
Easy installation with special components for each type of mounting and clear
instructions in accordance with standard working practices.

Multiple combinaisons in switchboard


FuPacT ISFL devices can be installed in the same rows with all the different
ratings.
Same accessories are existing to have the same lenght and new products
have been developped to have same lengh and deph.
Depending on the rating, 6 to 9 devices can be installed per row.

Simplified distribution in switchboard


FuPacT ISFT100 and 160 can be supplied via feeding busbars
connected to the main busbars.
All FuPacT ISFT range (except 630 A rating) can be supplied
directly by busbars with connection by hook-on.

Full functional-unit performance


Prisma offers a complete set of mounting plates, front plates and
prefabricated connection accessories for FuPacT that helps ensure
performance and ease of installation.
FuPacT

General contents Presentation


2

FuPacT ISFT
A

FuPacT ISFL
B

FuPacT GS
C

Catalog numbers
D

> Complementary
technical information > Prisma P > Prisma G

LVPED318033EN DESW016EN DESW015EN

1
Presentation www.se.com

General description of FuPacT fusegear

FuPacT ISFp (ISFT and ISFL)


2 ISFT horizontal fuse-switch disconnectors and ISFL vertical fuse-switch
disconnectors have the following functions:
bb on-load switching of circuits. The speed and force of the operation of this type of
PB115835.eps

fusegear are dependent on the action of the operator


PB107274_15.eps

bb the fuse-link blades form the moving contacts of the switch


bb the fuse-links are mounted in a fuse-carrier assembly
bb via the handle, the fuse-carriers operate the main moving contacts
bb isolation when the fuse-carrier assembly is in the open position (OFF)
bb protection against short-circuits and overloads on distribution circuits.
This function is provided by DIN blade-type industrial fuse-links (NH).
bb possibility for ISFL vertical fuse-switch disconnectors to have a 1-pole or 3-pole
variant.
bb Turnable contact hooks which is advantage in terms of installation. Possibility to
have an upstream or downstream distribution with the same product.
DB120077.eps

ISFp fuse-switch disconnectors


ISFp fuse-switch disconnectors

FuPacT GS (GSC, GSD and GSB)


FuPacT GS switch-disconnector fuses provide the following functions:
bb on-load switching of circuits. The speed and force of the operation of this type of
fusegear are independent of the action of the operator (fast opening and closing).
PB115836.eps

bb isolation with positive contact indication when the switch is in the open position
(OFF). The fuse-link is completely isolated from the power circuit (double breaking
technology).
bb protection against short-circuits and overloads on distribution circuits.
This function is provided by industrial fuse-links (NFC, DIN, BS) used in
conjunction with the switch-disconnector fuse device.
bb safety or emergency stop (red/yellow rotary handle option).
ISFT with turnable hooks

FuPacT operating modes


The FuPacT range integrates control, isolation and fuse-carrier functions in a single
device. These functions can also be implemented by combining separate
components.
PB121476.eps

DB120076.eps

FuPacT GS switch-disconnector fuses


GSp switch-disconnector fuses

Solutions combining separate components


It is also possible to protect distribution circuits and/or motors by combining
switch-disconnectors with fuse-links mounted on separate fuse-carriers.
The functions provided by each component are:
bb on-load switching of circuits (opening and closing) and isolation
PB111442_52.eps

(switch-disconnector).
bb protection against overloads and short-circuits (fuse).
bb the combination can implement Compact INS or INV switch-disconnectors
from 40 to 2500 A.
DB120078.eps

INS switch-disconnectors

Control
DB120079.eps
PB117726_L9.eps

Protection

Fuse-link

2
www.se.com
Presentation
General description of FuPacT fusegear

Compliance with standards Fupact ISFT160 Ith 160A 40°C

FuPacT fusegear complies with international standards and recommendations:


Ui 1000V
IEC 60947-3
Uimp 8kV
50/60 Hz 2
bb IEC 60947-1: general rules Ue (V) / le (A)AC21B AC22B AC23B

DB424788.ai
380/415V 160 160 -
bb IEC 60947-3: switches, disconnectors 500V 160 160 -
690V 160 - -
bb IEC 60947-5.1 and following: control-circuit devices and switching elements; DC21B DC22B
220V / nb pole 160/3 160/3
automatic control components. 440V / nb pole 125/3 -
-
-
These standards and recommendations are applied in most countries. Max(A) 160 Max(W) 12
FuPacT fusegear and auxiliaries comply with International standards (IEC 60947-1 HD 60269-2 DIN 43620-1
and IEC 60947-3). ISFT label
FuPacT GS and FuPacT ISFp are designed for use with industrial fuse-links
complying with the following standards:
bb IEC 60269
bb BS 88 (only for FuPacT GS)
bb DIN 43620 / VDE 0636.
FuPacT GS switch-disconnector fuses are suitable for the control of
machine-tools:

PB115835.eps
bb they comply with the requirements of the new machine directive IEC 60204
(EN 60204)
bb they comply with French standard NF C 79-130 and the recommendations issued
by the CNOMO organisation.
Climatic environment
FuPacT fusegear meets climatic requirements as defined in the following standards:
bb IEC 60068-2-30: damp-heat tests under off-load conditions, 95 % relative humidity
at 55 °C (hot and humid climate conditions) Fusegear with
bb IEC 60068-2-52: salt-mist tests, KB severity 2 tests terminal shields
bb IEC 60068-2-56: damp-heat tests under on-load conditions for 48 hours, IP20 and IK07
environment category C2 following Schneider quality specifications.
The fusegear can therefore be used in all climates.
Degree of pollution
FuPacT fusegear is certified for operation in pollution-degree 3 environments as
defined by IEC 60947 standard applying to industrial environments.
Ambient temperature
The FuPacT range can be used between -20 °C and +70 °C. Above 40 °C, you will
have to take account of the derating indicated in the documentation.
The devices must be commissioned at the ambient temperature indicated above.
The FuPacT range must be stored in its original packaging at a temperature between
-50 °C and +85 °C.
PB120396.eps

Degree of protection
For FuPacT fusegear with terminal shield, the degree of protection against direct
contact complies with standard IEC 60529 (IP index of protection) and IEC 62262:
bb with direct rotary handle: IP20/IK07
bb with extended rotary handle (FuPacT GS): IP65/IK10 Fusegear in an enclosure or cabinet (extended
bb with extended rotary handle and padlocks: IP65/IK08. handle);
GSp only.
Positive contact indication
IP65 and IK10.
IEC 60947-3 standard defines isolation with positive contact indication as follows:
bb the isolation position corresponds to the O (OFF) position
bb the operating handle cannot indicate the OFF position unless the main contacts
are not totally opened
bb locking in the OFF position is not possible unless the main contacts are actually
open.
PB120397.eps

GSp switch-disconnector fuses are suitable for isolation with positive contact
indication.
Installation of an extended handle on GSp fusegear does not alter the suitability for
isolation.

The isolation with positive contact indication function is certified by testing:


bb the mechanical reliability of the position-indication system
bb the absence of leakage currents
bb overvoltage withstand capacity between upstream and downstream connections.

Positive contact indication

3
www.se.com

A
D
ISFT100N ISFT100

ISFT160 ISFT250
ISFT400
ISFT630
www.se.com

FuPacT ISFT

Functions and characteristics


Fuse switch-disconnector selection
FuPacT ISFT100N to ISFT630.......................................................... A-4

Accessories and auxiliaries


FuPacT ISFT100N............................................................................ A-8 A
FuPacT ISFT160............................................................................. A-10
FuPacT ISFT250 to ISFT630.......................................................... A-11

General characteristics: ISFT


FuPacT ISFT100N to ISFT630........................................................ A-12

ISFT installation
FuPacT ISFT100N to ISFT630 ....................................................... A-14

Connection and accessories


FuPacT ISFT100N to ISFT630 - Connection.................................. A-16
FuPacT ISFT160 to ISFT630 - Reverse distribution....................... A-18
FuPacT ISFT100 and ISFT160 - Connection, coupling................. A-19
FuPacT ISFT100N, ISFT160 to ISFT400 -
Different installation systems.......................................................... A-20

Fuse monitor
FuPacT ISFT160 to ISFT630.......................................................... A-22

Insulation
FuPacT ISFT100N to ISFT630........................................................ A-24

Fuse-link monitoring and testing


FuPacT ISFT160 to ISFT630.......................................................... A-25

Control, locking and operation


FuPacT ISFT100N to ISFT630........................................................ A-26

Auxiliary contacts and indications


FuPacT ISFT100N to ISFT630........................................................ A-28

Other chapters
Presentation....................................................................................................2
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1

A-1
www.se.com

FuPacT ISFT

Installation recommendations
Possible installation positions and mounting
FuPacT ISFT100N to ISFT630........................................................ A-30

Implementation and power dissipation


A FuPacT ISFT................................................................................... A-31

Other chapters
Presentation....................................................................................................2
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1
www.se.com

FuPacT ISFT

Dimensions and connection


FuPacT ISFT100N ................................................................ A-33
Dimensions and mounting.............................................................. A-33
Front panel cut-outs - Connection and accessories...................... A-34

FuPacT ISFT100 A
Dimensions..................................................................................... A-35
Mounting and front panel cut-outs................................................. A-36
Connection and accessories.......................................................... A-37

FuPacT ISFT160
Dimensions..................................................................................... A-39
Mounting and front panel cut-outs................................................. A-40
Connection and accessories.......................................................... A-41

FuPacT ISFT250 to 630


Dimensions and mounting.............................................................. A-43
Mounting and front panel cut-outs................................................. A-44
Connection and accessories.......................................................... A-45

Wiring diagrams
FuPacT ISFT........................................................................... A-47

Other chapters
Presentation....................................................................................................2
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1

A-3
Functions and characteristics www.se.com

Fuse switch-disconnector selection


FuPacT ISFT100N to ISFT630

Fuse switch-disconnectors
Number of poles / type of fuse-link IEC 60269-2-1 Section 1
Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3
PB115837.eps

Conventional thermal current (A) In free air Ith at 40 °C


Maximum fuse power dissipation (W)
In enclosure Ithe at 40 °C
Maximum fuse power dissipation (W)

A
Rated insulation voltage (V) Ui AC 50/60 Hz / DC
Rated impulse withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
DC
Rated operational voltage AC20 and DC20 (V) Ue
Rated operational current (A) Ie AC 50/60 Hz
220/240 V
ISFT100N 380/415 V
440/480 V [1]
500 V
660/690 V
DC/poles in series
220 V /no. of poles
PB115838.eps

440 V /no. of poles


Rated duties Uninterrupted duty
Rated short-circuit breaking capacity (kA rms)/Rated Icn/Icm/In 415 V
short-circuit making capacity (kA peak)/Fuse-link In (A) [2] 500 V
690 V
Endurance (category B) (CO cycles) Mechanical
Electrical AC AC22B 415 V
ISFT100
AC23B 415 V
AC22B 500V
AC21B 500V
AC22B 690V
AC21B 690 V
Suitability for isolation
Positive contact indication
PB115839.eps

Pollution degree
Control
Direct front rotary handle (operator-dependent opening and closing)
Locking Padlocks
Lead seal
Indication auxiliaries
Auxiliary contacts
ISFT160
Fuse monitor
Installation and connection accessories
Possible mounting positions Horizontal
Vertical
PB115835.eps

Bare cable connectors


Other connectors For bare Cu/Al cables
For flexible bars
Distribution connectors
Lugs for copper cables
Incoming connector for feeding busbars
Terminal shields
Dimensions and weight
Overall dimensions H x W x D (mm) 3P
Approximate weight without fuse-links (kg) 3P
[1] Suitable for 480 V NEMA.
[2] Fuse-switch disconnectors with fuse-links.
[3] AC23B 160A
[4] AC23B 250 A.
ISFT250-400-630 [5] AC23B 400 A.
[6] AC23B 630 A.

A-4
www.se.com
Functions and characteristics
Fuse switch-disconnector selection
FuPacT ISFT100N to ISFT630

ISFT100N ISFT100 ISFT160 ISFT250 ISFT400 ISFT630


3P/DIN (NH) 3P/DIN (NH) 3P/DIN (NH) 3P/DIN (NH) 3P/DIN (NH) 3P/DIN (NH)

100 100 160 250 400 630


9 9 12 23 34 48
100 100 160 250 400 630
9 9 12 23 34 48

A
1000 690 1000 1000 1000 1000
6 6 8 8 8 8
690 690 690 690 690 690
440 440 440 440 440 440
800 800 800 800 800 800
AC21B AC22B AC21B AC22B AC21B AC22B AC21B AC22B AC21B AC22B AC21B AC22B
100 100 100 100 160 160 [3] 250 250 [4] 400 400 [5] 630 630 [6]
100 100 100 100 160 160 [3] 250 250 [4] 400 400 [5] 630 630 [6]
100 100 100 - 160 160 250 250 400 400 630 630
100 100 100 - 160 160 250 250 400 400 630 630
100 - 100 - 160 - 250 250 400 400 630 630
DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B
100/3 100/3 100/3 - 160/3 160/3 250/3 250/3 400/3 400/3 630/3 630/3
100/3 100/3 100/3 - 125/3 - 250/3 - 400/3 - 630/3 -

80/5.1kA peak/100 A 80/ 3 kA /100 A 80/ 5 kA peak /160 A 80/ 15 kA peak /250 A 80/ 22.1 kA peak /400A 80/ 25.2 kA peak /630 A
80/5.1kA peak/100 A 50/ 3 kA /100 A 80/ 5 kA peak /160 A 80/ 15 kA peak /250 A 80/ 22.1 kA peak /400A 80/ 25.2 kA peak /630 A
80/5.1kA peak/100 A 50/ 3 kA / 100 A 80/ 5 kA peak /160 A 80/ 15 kA peak /250 A 50/ 22.1 kA peak /400A 80/ 25.2 kA peak /630 A
2000 2000 1600 1600 1000 1000
300 300 200 200 200 200
300 - 200 200 200 200
300 - 200 200 200 200
- 300 - - - -
- - - 200 200 -
300 300 200 200 200 200

3 3 3 3 3 3

- - - - - -

- -

- - -
- -
- -
- - - -
- -
- - - -
-

216 x 53 x 80 141 x 89 x 71 206 x 106 x 80 306 x 184 x 110 306 x 210 x 130 306 x 250 x 130
0.54 0.46 0.60 2.00 2.00 3.50

A-5
Functions and characteristics www.se.com

Fuse switch-disconnector selection


FuPacT ISFT100N to ISFT630

Fuse switch-disconnectors
Type of fuse-link
DIN/NH000
PB115837.eps

DIN/NH00
DIN/NH1
DIN/NH2
DIN/NH3
A Installation and connection
Symmetrical rail
Direct connection on backplate
Hook-on connection to 60 mm busbars
Tightening torque (Nm)
ISFT100N Temperature derating (with gG fuse-link) [1] [2]
“Vertical mounting” Ith (A) 40 °C
fuse-links in vertical position 45 °C
50 °C
55 °C
60 °C
65 °C
PB115838.eps

70 °C
“Horizontal mounting” Ith (A) 40 °C
fuse-links in horizontal position 45 °C
50 °C
55 °C
60 °C
ISFT100 65 °C
70 °C
Degree of protection (from the IP3X
front face and inclosed position)
Mechanical shock IK07
[1] Derating data is based on:
PB115839.eps

- the maximum rating for fuse-links intended for the device,


- maximum power dissipation.
[2] For installation on a ceiling, derate an additional 10 %.

ISFT160
PB115835.eps

ISFT630

A-6
www.se.com
Functions and characteristics
Fuse switch-disconnector selection
FuPacT ISFT100N to ISFT630

ISFT100N ISFT100 ISFT160 ISFT250 ISFT400 ISFT630


- - - -
- - - - -
- - - - -
- - - - -
- - - - -

- - -
A
- -
see page B-4

100 100 160 250 400 630


95 95 152 238 380 599
90 90 144 225 360 567
85 85 136 213 340 536
80 80 128 200 320 504
75 75 120 188 300 473
70 70 112 175 280 441
100 100 160 250 400 630
95 95 152 238 380 599
90 90 144 225 360 567
85 85 136 213 340 536
80 80 128 200 320 504
75 75 120 188 300 473
70 70 112 175 280 441

A-7
Functions and characteristics www.se.com

Accessories and auxiliaries


FuPacT ISFT100N

FuPacT ISFT100N
DB430652.ai

A B C

A DIN rail fixing kit C Laterally attachable support profile


B Terminal cover D NO + NC auxiliary changeover contacts

A-8
www.se.com
Functions and characteristics
Accessories and auxiliaries
FuPacT ISFT100

A B C
DB430653.ai

F E D

A NO + NC auxiliary changeover contacts C Feeding busbars to supply : E Accessory for mounting on DIN rail
b 2 devices
B Incoming connector for feeding busbars F Escutcheons for:
b 3 devices
b 4 devices b 1 device
D Distribution connector b 2 devices

A-9
Functions and characteristics www.se.com

Accessories and auxiliaries


FuPacT ISFT160

A B C D
DB430654.ai

G F E

A NO + NC auxiliary changeover contacts E Connectors for :


b bare cable
B Incoming connector for feeding busbars
b distribution
C Feeding busbars to supply : b flexible bar
b 2 devices F Fuse monitor
b 3 devices
b 4 devices G Laterally attachable support profile
D Long terminal shield

A-10
www.se.com
Functions and characteristics
Accessories and auxiliaries
FuPacT ISFT250 to ISFT630

A B C
DB430655.ai

F E D

A NO + NC auxiliary changeover contacts D Connectors for bare cable


B Long terminal shield E Lug for copper cable
C Laterally attachable support profile F Fuse monitor

A-11
Functions and characteristics www.se.com

General characteristics: ISFT


FuPacT ISFT100N to ISFT630

FuPacT ISFT offers innovative solutions


PB115835.eps

The FuPacT ISFT is a modern approach to power distribution with modular


switchgear that is simple to install and reliable.
On the FuPacT ISFT the entire covers can easily be removed while the switching
cover remains closed, thus eliminating the need for elaborate trim frames and
extensions.
Integrated hand protection and a sliding viewing window enable voltage tests to be
A conducted on contact blades or strap handles. FuPacT ISFT offers two types of
cable connection: cable lug or clamp connector for copper or aluminum conductors.
All FuPacT ISFT can be sealed and fitted with a locking mechanism. FuPacT ISFT
also provides a patented system of turnable hooks for converting the outgoing
arrangement from top to bottom and vice versa. The fuse-switch-disconnectors can
be attached, positioned and tightened effortlessly.

Smallest 100 A solution on market: ISFT100N


FuPacT ISFT offers two sizes for 100 A rating.
bb Basic (without connection on busbar system), with a width of 106 mm.
bb Narrow, which is the smallest 100 A solution on the market (connection on busbar
system possible), with a width of 53 mm.
Objectives of this product is to reduced installation space and to propose two 100 A
(106 mm width) replace one 160 A product (106 mm width also).
PB115837.eps

FuPacT ISFT for mounting on base plates


The disconnectors for mounting on base plates, sizes 000, 00, 1, 2 and 3, come with
a number of predrilled fastening holes that allow these models to be used on base
plates or on profiles. With the appropriate accessories, the sizes 000 and 00 can be
mounted on DIN rail.

Accessories
Support Profile Laterally attachable
This accessory allows to enlarge the cut-out tolerances of the cover plates while also
supporting these plates.
bb Latchable bracket on the side.
bb Allows greater cutting tolerances.

Switching cover position indicator:


PB117723_L54.eps

bb 1 close contact and 1 open contact.

Intelligent measurement
Electronic Fuse-Monitoring - Everything under control
Thanks to the electronic Fuse Monitor, technician could receive an information to
localize a short circuit or overload. Maintenance will be more reactive to change fuse
which is broken.

FuPacT ISFT range from size 00 to 3 has an electronic fuse monitor


The electronic fuse monitor is directly attached to the switching cover.
This installation depth is 28 mm.
A light-emitting diode starts blinking red the moment the fuses fail. A test button and a
4-pole connector for remote indication are attached to the housing.

Note: for more technical informations, see page A-22.


PB115845.eps

A-12
www.se.com
Functions and characteristics
General characteristics: ISFT
FuPacT ISFT100N to ISFT630

Safety

PB115840.eps
FuPact ISFT provides:
bb Protection against accidental contact in the standard model:
vv terminal housing closed
vv simple break-out for all versions
vv terminal shield needed for specific application (> 500 V)
vv IP3X
vv life part are covered.
bb Switching with integrated and extended hand protection feature:
A
vv prevents fuse-unit contact
vv protection against electric arc.
bb Voltage test thanks to independent slidable windows
bb Snap-on busbar cover to protect against direct contact.
bb Locking cover with sealing facility:
vv locking mechanism for switching cover for non-instructed individuals
vv switching cover is sealable.

Fast connection thanks to box terminals

PB115841.eps
For FuPacT 160 A size 00
bb Advantageous box terminals:
vv Cu conductor from 2,5 to 95 mm2
vv no cable lug needed.
bb Or universal screw terminal for M8 cable lug.

Options
bb Prism clamp 6…70 mm2. Cu/Al.
bb Terminal 3 x 16 mm2.

For FuPacT 250 to 630 A sizes 1–3


bb The standard version:
vv size 1 and 2 for M10 cable lug

PB115842.eps
vv size 3 for M12 cable lug.
bb Easy to change the various types of connection.

Options
bb Prism clamp for Cu.
bb Prism clamp for Cu/Al (1x cable).
bb Prism clamp for Cu/Al (2x cables).

Turnable contact hooks


FuPacT ISFT is the first horizontal fuse switch-disconnector to propose turnable
contacts hooks. This makes it easier to mount FuPacT ISFT on the busbar in
addition to being more flexible. Due to its symmetry, FuPacT ISFT can be turned
around at any time. Terminal top or bottom can be choosen freely. Thus, only one
version needs to be stored.
PB115843.eps

bb One universal solution for top or bottom cable outlet.


bb Reduced stock.
bb Universal to busbar thickness.
bb More installation flexibility.

A-13
Functions and characteristics www.se.com

ISFT installation
FuPacT ISFT100N to ISFT630

ISFT fusegear is installed on a mounting plate, DIN rail or on busbars, depending on the power rating.
Connections are made via cables or directly to the busbars via hook-on.

ISFT100N fusegear
Installation on a mounting plate, on busbars 60 mm or DIN rail on busbars with:
A bb cables or flexible bars
bb hook-on connection to 60 mm busbars.
Upstream or downstream connection of distribution circuits requires cables or
flexible bars.
PB117721_L32.eps

ISFT100N (hook-on connection)

DB423159.eps

DB423160.eps
DB423158.eps
DB120097.eps

Hook-on connection to busbars:


the device tightly hooks on to the busbars
via three hooks that allows for both
electrical connection and performant
mechanical mounting. The connection ISFT100 fusegear
systems can also be reversed to supply Installation on a mounting plate or symmetrical DIN rail.
distribution circuits via the upstream Power and distribution circuit connections require cables and built-in connectors.
terminals.
This system allows direct contact of the
power circuit to the busbars (no cables,
no bars, no drilling, etc.) and usual
DB423161.eps

DB423162.eps

connections for downstream distribution


(bare cable connectors, lugs, bars,
distribution connectors, etc.).

A-14
www.se.com
Functions and characteristics
ISFT installation
FuPacT ISFT100N to ISFT630

ISFT160 fusegear
Installation on a mounting plate or on busbars with:
bb cables or flexible bars
bb hook-on connection to 60 mm busbars
A
Downstream connection of distribution circuits requires cables or flexible bars.

PB115844.eps
Hook-on connection (ISFT250 and 2 x ISFT160)
DB423163.eps

DB423164.eps

ISFT250 to ISFT630 fusegear


Installation on a mounting plate or on busbars with:
bb cables or flexible bars
bb hook-on connection to 60 mm busbars (except ISFT630)
Downstream connection of distribution circuits requires cables or flexible bars.
DB423166.eps

DB423167.eps

A-15
Functions and characteristics www.se.com

Connection and accessories


FuPacT ISFT100N to ISFT630 - Connection

FuPacT fuse-switch disconnectors can supply distribution circuits via either the upstream or downstream terminals.
Devices intended for connection to busbars are configured as standard for distribution via the downstream terminals.

ISFT fusegear is equipped with connectors or terminals for front connection of:
bb bare cables for ISFT100N to ISFT160 devices
bb cables with lugs for ISFT160 to 630 devices

A bb flexible bars for ISFT160 to 630 devices.

ISFT100N ISFT100 ISFT160 ISFT250 ISFT400 ISFT630


Cables
Connector 2.5 to 50 mm2 1.5 to 50 mm2 -
Lug to terminal - - 120 to 185 mm2 120 to 300 mm2
Connector to terminal - - 2.5 to 95 mm2 6 to 150 mm2 6 to 240 mm2
box clamp re/se 6 to 50 mm2 35 to 150 mm2 95 to 300 mm2
rm/sm 6 to 25 mm2 50 to 150 mm2 120 to 300 mm2
Presure Plate
Connector - - 6 to 70 mm2 70 to 150 mm2 120 to 240 mm2 150 to 300 mm2

ISFT100N fusegear
DB423169.eps
DB120179.eps

ISFT100 fusegear
62315a_2.eps

DB423171.eps
DB423170.eps

Distribution connector
62316a_2.eps

Incoming connector for


feeding busbar
LV480811_L30.eps

DB424792.eps

Feeding busbar

A-16
www.se.com
Functions and characteristics
Connection and accessories
FuPacT ISFT100N to ISFT630 - Connection

ISFT160 fusegear

DB120162.eps
A
DB423173.eps

DB423174.eps

62330a_1-2_r.eps
Lug for copper cables

LV480814_L17R.eps
Distribution connector
DB423175.eps

DB424797.eps

LV480816_L15.eps

Connector for bare Cu/Al cables


LV480815_L19.eps

Connector for flexible bars


ISFT250/400/630 fusegear
DB120162.eps
DB423177.eps

DB423178.eps

62330a_1-2_r.eps

Lug for copper cables


LV480823_L19.eps

Connector for bare Cu/Al cables


DB423179.eps

DB424798.eps

LV480829_L22.eps

Connector for flexible bars

A-17
Functions and characteristics www.se.com

Connection and accessories


FuPacT ISFT160 to ISFT630 - Reverse distribution

FuPacT fuse-switch disconnectors designed for connection to busbars supply distribution circuits via the
downstream terminals as standard. In the case of ISFT160 to ISFT630 devices, simple installation operations allow
power to be supplied to the distribution circuits from upstream. In the case of ISFT100N devices, the method of
distribution cannot be reversed simply by changing the direction of the mounting. There are separate references for
each particular case.

A To reverse supply, depending on the model, simply turn 180°:


bb either the base with its connection kit
bb or the connection kit alone.
For fusegear with a fuse monitor, the fuse monitor cover must be changed given that
different versions are used depending on whether supply is via the upstream or
downstream terminals.
Operation to reverse supply (upstream/downstream terminals)
180° rotation Change
Base Turnable hooks Fuse monitor
cover

DB425101.eps
DB401353.eps

DB401355.eps
DB120103.eps

ISFT160 to 400 yes yes yes


Hook-on connection: the orientation of the hooks on
ISFT630 yes no yes
the busbars is always the same, whether the
distribution circuits are connected to the upstream or ISFT160 yes - yes
downstream terminals. The fuse-switch disconnectors
ISFT250 yes - yes
must physically hang on the busbars.

Fusegear with hook-on connection


ISFT160/400
DB423180.eps
DB120104.eps

Symmetrical slots on the side of the base make it


possible to raise and lower the cover that forms the
fuse-carrier.
Turnable hooks
DB425096.eps

A-18
www.se.com
Functions and characteristics
Connection and accessories
FuPacT ISFT100 and ISFT160 - Connection, coupling

It is possible to supply several ISFT100 and ISFT160 fusegears by using feeding busbars via a single incomer.

Supplying a several of devices via feeding busbars


Incoming connectors are used for the upstream power cables.
Power is distributed to the other devices via feeding busbars or a combination of feeding busbars.
Downstream connection of distribution circuits is done via cables.
ISFT100 ISFT160
A
2 devices

max. max.
100 A 125 A
DB423186.eps

DB425093.eps

3 devices

max. max.
160 A 160 A
DB423187.eps

DB425094.eps

4 devices
DB423188.eps

DB425095.eps

max. max.
160 A 160 A

Combinations: Feeding busbars


bb 2 devices: Maximum operating voltage 690 VAC
vv 1 incomer for 2 outgoers
Insulation coordination overvoltage category III /
bb 3 devices [1]: pollution degree 2
vv 1 incomer for 3 outgoers Busbar cross-section 35 mm2
bb 4 devices [1]:
vv 1 incomer for 4 outgoers. The maximum current per phase when the feed is
connected to a busbar extremity is 125 A.
If the feed is connected at the center of the busbar, the total outgoing current of each The maximum current per phase when the feed is
connected at any busbar position is 160 A.
busbar branch must not exceed the maximum busbar current per phase.

[1] For combinations of more than 2 ISFT100 devices, it is recommended to connect incoming
power to the second device to reduce temperature rise.

A-19
Functions and characteristics www.se.com

Connection and accessories


FuPacT ISFT100N, ISFT160 to ISFT400 -
Different installation systems

Many connection and supply possibilities


Supplying a set of busbars from an incoming device
ISFT250

ISFT250

A
DB4430686.eps
ISFT400

[1]

ISFT100N

ISFT160
DB4430687.eps

[1]

[1] Linergy BZ busbar system: for more technical informations, see page D-6.

A-20
www.se.com
Functions and characteristics
Connection and accessories
FuPacT ISFT100N, ISFT160 to ISFT400 -
Different installation systems

Supplying a set of busbars from an incoming device


ISFT250

ISFT250

A
DB4430688.eps

ISFT250

NSX400/630

L3
L2
L1

L1

12 Nm

L2

12 Nm

L3

12 Nm

L3
L2
L1

ISFT160
DB430665.eps

ISFT160

ISFT400

A-21
Functions and characteristics www.se.com

Fuse monitor
FuPacT ISFT160 to ISFT630

Functions
PB115845.eps

This device provides remote indication of the status of standard fuses (without
strikers). It serves to:
bb it signals a blown fuse
bb it helps prevent the risks of abnormal voltages on the neutral.

Standards
A bb Compliance with international standard IEC 60947-5-1.
bb Compliance with:
vv EN 50204
vv EN 61000 for electromagnetic compatibility (EMC).

Description
bb Characteristics:
ISFT160 fuse monitor vv operation with DIN fuses.
vv degree of protection: IP20.
bb May be used on capacitor bank circuits.
bb Simplified power supply:
vv does not require a specific power supply
vv operates with unbalanced phases
vv supplied via connection to the fuse terminals on the fusegear devices
vv operational voltage: 400…690 V AC, ±10 %, 50/60 Hz.
bb Tested for electromagnetic compatibility (EMC).
bb Mounting:
vv connected to the fuse-carrier assembly forming the cover.
bb The package consists of:
vv a fuse-carrier/handle and fuse monitor sub-assembly supplied as a kit
composed of:
- fuse monitor equipped with one NO contact and one NC contact
- fuse-carrier with the handle
vv the customer must remove his fuse-carrier/handle assembly from his product
and replace it with this kit.
bb Characteristics:
vv IP20 degree of protection
vv product with fuse monitor must be integrated inside switchboards and not in
front face in case of customers wants to have a complete class II insulation.
Class II insulation with switchboard in front face is effective only when FuPacT
ISFT is in closed position and with a door or a protection behind the fuse
monitor.

Operation
Reset
The device is automatically reset when the fuse-links are replaced.
Indications
bb Normal operation:
vv the green LED is ON when voltage is present at the fuse terminals
vv the contacts are in the rest position.
bb Operation when a fuse blows:
vv the green LED goes off and the red LED goes on
vv the contacts are actuated:
- the NO contact is for remote fault indication
- the NC contact may be used, for example, to control an undervoltage device
in order to shut down equipment that may be sensitive to single-phasing.

> FuPacT ISFT160 to 630 fuse monitor


Instruction sheet

NVE88766

A-22
www.se.com
Functions and characteristics
Fuse monitor
FuPacT ISFT160 to ISFT630

Electrical characteristics
Power circuit
Rated operational voltage 400 to 690 V AC 50/60 Hz ±10 %
Consumption < 3 VA
Rated frequency 50/60 Hz
Measurement impedance > 1000 W/V
Rated impulse withstand voltage (1.2 / 50 ms) 8 kV
Auxiliary contact output terminals
Terminal indications NO 13 - 14 A
NC 21 - 22
Cable capacity Flexible y 1.5 mm2 Cu
Rigid y 2.5 mm2 Cu
Output contact characteristics (1NO + 1NC)
Conventional thermal current Ith (A) 5
Rated insulation voltage (V) 250
Minimum load 10 mA at 24 V
Characteristics AC DC
Utilisation category (IEC 60947-5-1) AC12 AC15 DC12 DC13
Operational current (A) 24 V - 3 - 2
48 V - 3 - -
110 V - 3 - -
220/240 V - 3 - -
250 V - 3 - -
380/415 V - - - -
440 V - - - -
660/690 V - - - -
Rated operational voltage / max. breaking voltage (V AC) 250/440
Breaking capacity (VA) 2000

General characteristics
Operating temperature range (°C) -25…+55 (y 500 V) -25…+45 (> 500 V)
Storage and transport temperature range (°C) -40…+70
Fuse blowing detection time (s) <2
Overvoltage category / degree of pollution IEC 60947-1 3
Dielectric test voltage (between power circuit and output terminals) 5 kV rms / 1 min 50 Hz
Electromagnetic compatibility - emission
Conducted EN 55022 Class B
Radiated EN 55022 Class B
Harmonic currents EN 61000-3-2 Class A
Electromagnetic compatibility - immunity
Electrostatic discharge (ESD) EN 61000-4-2 category B level 2/3
Radiated field susceptibility (RF) EN 61000-4-3 category A level 3
Surge immunity test EN 61000-4-5 level 4
Conducted low energy susceptibility (EFT) EN 61000-4-4 category B level 3
Conducted high energy susceptibility (RF) EN 61000-4-6 category A level 3
Radio-frequency interference (GSM) ENV 50204 category A
Magnetic field immunity
Continuous EN 61000-4-8 level 5

Mechanical characteristics
Degree of protection IP20
Weight (fuse monitor alone) (kg) 0.2
Dimensions

33
DB424799.eps

83

45

A-23
Functions and characteristics www.se.com

Insulation
FuPacT ISFT100N to ISFT630

Some accessories for insulation are used to prevent direct contact with the main circuits.
For ISFT100, we have single and double escutcheon (with 1 free slot). These escutcheons, which could be used in
combination, allow one type of cut-out on the front panel of switchboard. But in case of feeding busbars, The use of
escutcheon is not compliant with feeding busbars.
For ISFT100N and ISFT160 to 630 , side profiles (or laterally attachable) provide vertical IP level across the door.
The switchboard manufacturer must provide the horizontal IP.
For those products, it’s mandatory to use terminal shield when voltage is upper or equal to 500 V.
A
Insulation of live parts
Escutcheon
Clipped on the device, escutcheons provide IP20 and IK07 degrees of protection.
Type Escutcheon type Terminal shield

ISFT100N - -
ISFT100 - -
ISFT160
ISFT250
ISFT400
ISFT630

62306a_4.eps
ISFT100N fusegear - Terminal shield and escutcheon

Escutcheon
DB423192.eps

DB423193.eps

62307a_1-88.eps

Terminal shields

ISFT100 fusegear - Escutcheon


62310a_4.eps
DB423195.eps

Escutcheon

ISFT160 to ISFT630 fusegear - Terminal shields and escutcheon


PB104315-23.eps
DB423196.eps

DB425097.eps

Laterally attachable
support profile

A-24
www.se.com
Functions and characteristics
Fuse-link monitoring and testing
FuPacT ISFT160 to ISFT630

Monitoring
ISFT 160 to 630 fuse-switch disconnectors are equipped with independant large
windows so that the fuse-link technical characteristics are clearly visible.

PB115839.eps
A
DB423199.eps

ISFT160

Testing
PB115846.eps
DB423200.eps

Independant sliding covers on the front panel provide access to the fuse-link status
test points while maintaining the IP20 protection index.

A-25
Functions and characteristics www.se.com

Control, locking and operation


FuPacT ISFT100N to ISFT630

The main moving contacts are controlled by the pivoting fuse-carrier assembly forming the cover for the ISFT devices
In open position, the fuse-switch disconnector fuse-carrier assembly provides isolation with visible break.

Control
A
DB423201.eps
PB115847.eps

ISFT100N.

Locking
DB120139.eps

ON
PB119107.eps

DB423202.eps

ISFT400

Access to the fuse-links:


b may be provides by lead seals on the ISFT
devices

Lead-seal locking for the


ISFT100N

To lock the fuse-switch disconnector in closed


(ON) position, the fuse-carrier is equipped as
standard with a locking part.
DB423203.eps
PB115842.eps

Lead-seal locking
for the ISFT100 to ISFT630
devices
Locking in open (OFF) position isolation as defined by IEC 60947-3.

Type Function Means Accessory


ISFT100N Device locking in closed Lead seal Built-in
ISFT100 (ON) position
ISFT160
ISFT250 to ISFT630

A-26
www.se.com
Functions and characteristics
Control, locking and operation
FuPacT ISFT100N to ISFT630

For ISFT fusegear devices, the fuse-carrier cover is used both to control the device and to protect the fuse-link.
b ISFT100N: the pivoting fuse-carrier assembly accepts two fuse-links side by side and a third situated under the first
two fuse-links.
b ISFT100 to ISFT630: the pivoting fuse-carrier assembly accepts the three fuse-links side by side.

Fuse-carriers
Compatibility between ISFT fuse-switch disconnectors
A
and fuse-links (NH)
DB423204.eps

Pivoting fuse-carrier assembly for the ISFT100N


DB423205.eps

Pivoting fuse-carrier assembly for the ISFT100 to ISFT630 devices

Type of DIN NH000 NH00 NH1 NH2 NH3


fuse-link
ISFT100N - - - -
ISFT100 - - - -
ISFT160 - - - -
ISFT250 - - - -
ISFT400 - - - -
ISFT630 - - - -

Insertion and removal of fuse-links


Fuse-links are held in place by clips behind the front panel of the fuse-carriers, thus
making removal possible without touching the fuse-links.

A-27
Functions and characteristics www.se.com

Auxiliary contacts and indications


FuPacT ISFT100N to ISFT630

The optional auxiliary contacts carry out indication functions.


They provide remote indication of the fuse-switch disconnector status. They may
also be used to indicate and carry out automatic functions such as electrical
interlocking.

Standards: compliance with international recommendation IEC60947-5-1.


Description: NC/NO changeover contact.

A Functional table of contact status


Auxiliary changeover contact
Maximum number

ISFT100N 1
ISFT100 2
ISFT160 2
ISFT250 2
ISFT400 2
ISFT630 2

Auxiliary changeover contact for ISFT100N and ISFT160


Conventional thermal current Ith (A) 2
Rated insulation voltage (V) 250
Minimum load 100 mA at 24 V
AC DC
Load AC12 AC15 DC12 DC13
Rated operational current (A) 24 V 6 - 3 -
48 V 6 - 1 -
110 V 6 - 0.5 -
220/240 V 6 - 0.25 -

Auxiliary changeover contact for ISFT100 and ISFT250 to 630


Conventional thermal current Ith (A) 2
Rated insulation voltage (V) 250
Minimum load 100 mA at 24 V
AC DC
Load AC12 AC15 DC12 DC13
Rated operational current (A) 24 V 2 - 0.2 -
48 V 2 - 0.2 -
110 V 2 - 0.2 -
220/240 V 2 - 0.2 -

A-28
www.se.com
Functions and characteristics
Auxiliary contacts and indications
FuPacT ISFT100N to ISFT630

Position of auxiliary contacts for ISFT devices


ISFT100N ISFT100

A
DB423207.eps

DB423227.eps

PB119122.eps
ISFT160

Auxiliary contact for ISFT100


DB425098.eps

PB104316-20.eps

Auxiliary contact for ISFT100N/160


ISFT250/400/630
LV480833_L16.eps
DB423230.eps

Auxiliary contact for ISFT250/400/630

A-29
Installation recommendations www.se.com

Possible installation positions and mounting


FuPacT ISFT100N to ISFT630

Possible installation positions


ISFT100N to ISFT630

A
DB423438.eps

DB423439.eps
DB423440.eps

DB423441.eps
Possible mounting
ISFT100N and ISFT100 ISFT100N to ISFT630
DB423444.eps

DB423445.eps

DIN rail Plain mounting plate

ISFT100N ISFT100N to ISFT630


ISFp160 to ISFp630
ISFL1250
DB423446.eps

DB423447.eps

Secured to busbars Slotted mounting plate

A-30
www.se.com
Installation recommendations
Implementation and power dissipation
FuPacT ISFT

Reverse supply
FuPacT fusegear may be supplied equally well via the upstream or downstream
terminals, without any reduction in performance.

Conductor materials and electrodynamic forces


FuPacT fusegear may be connected using either bare copper, tinned copper or
tinned aluminium conductors (flexible or rigid bars, cables).
In the event of a short-circuit, thermal and electrodynamic forces are exerted on the
conductors. The conductors must therefore be adequately sized and suitably
A
supported.
Note that the terminals of electrical devices (switch-disconnectors, contactors, circuit
breakers, etc.) should not be considered to contribute to the support of the
conductors.

Cable ties and flexible bars


The table below indicates the maximum distances between cable ties depending on
the prospective short-circuit current.
Care must be taken not to exceed a distance of 400 mm between ties mechanically
fixed to the switchboard frame.

Type of tie “Panduit” type “Sarel” type


Width: 4.5 mm Width: 9 mm
Max. load: 22 kg Max. load: 90 kg
Color: white Color: black
Max. distance 200 100 50 350 200 100 70 50 (double
between ties (mm) ties)
Short-circuit current 10 15 20 20 27 35 45 100
(kA rms)
Note: for cables u 50 mm2, 9 mm wide ties must be used.

Tightening torque for ISFT with screw connection


Type Torque
(Nm)
ISFT ISFT100N mounted on backplate with connection terminals 4.5
ISFT100N with hook-on connection to 60 mm busbars 4.5
ISFT100 mounted on backplate with connection terminals 3
ISFT160 mounted on backplate with connection terminals 12
ISFT160 with hook-on connection to 60 mm busbars 12
ISFT250 mounted on backplate with connection terminals 20
ISFT250 with hook-on connection to 60 mm busbars 20
ISFT400 mounted on backplate with connection terminals 20
ISFT400 with hook-on connection to 60 mm busbars 20
ISFT630 mounted on backplate with connection terminals 20

A-31
Installation recommendations www.se.com

Implementation and power dissipation


FuPacT ISFT

Power dissipated by ISFT fuse-switch disconnectors


Power dissipated per pole
Switchgear Fuse-link Total
Rating Model Resistance Power Max. power Total power
per pole dissipated dissipated dissipated per
per pole pole
(A) (mW) (W) Rat. (A) P (W) (W)

A Fixed front-connected device (without conversion kit) 100


100
ISFT100N
ISFT100
0.33
0.150
3.3
3.6
100
100
7.5
7.5
11
11
160 ISFT100 0.151 3.8 160 8.2 12
160 ISFT160 0.117 3.0 160 12 15
250 ISFT 250 0.056 6 250 23 29
400 ISFT400 0.046 10 400 34 44
630 ISFT630 0.045 19 630 48 67
With 60 mm hook-on connection 100 ISFT100N 0.37 3.7 100 7.5 11
conversion 60 mm hook-on connection 160 ISFT160 0.220 5.6 160 12 17
kit
60 mm hook-on connection 250 ISFT250 0.086 6.7 250 23 30
60 mm hook-on connection 400 ISFT400 0.075 5.3 400 34 46

A-32
www.se.com
Dimensions and connection
FuPacT ISFT100N
Dimensions and mounting

Dimensions
Device to be installed on a backplate or DIN rail
Fuse-carrier closed Front Fuse-carrier open

65

A
DB425174.eps

DB425175.eps

DB425176.eps
X X X

216

174

82 26.5
53
52
Z Y
220
Z
Device to be installed on a busbar
Fuse-carrier closed Front Fuse-carrier open

[a] 31
DB425177.eps

DB425178.eps

DB425179.eps

60
23 X
X X

206

174

31

26.5 76
20 106 53 244
Z
Z Y
[a] Terminal shields.

Mounting
On backplate On DIN rail
16.5 16.5
(b)
3 Ø7

35
DB425180.eps

DB425181.eps

DB425182.eps

X X X 20
X

83 125 min. (b)


150 max. (c)
(c)

32.5
X

Y Y

A-33
Dimensions and connection www.se.com

FuPacT ISFT100N
Front panel cut-outs - Connection and accessories

Mounting (cont.)
On 60 mm busbars

23
DB425183.eps

DB425184.eps
X X

A 60

150

60

30

5...10
Z Y

Front panel cut-outs


Device to be installed on a Cut-out for 1 device [1] Cut-out for 2 devices [2]
backplate or DIN rail
[b] [b]
DB425890.eps

DB425186.eps

DB425187.eps
48 48
DB425185.eps

X X X X

185 185

27 27
63 54 113
46
Y Y
Z Y
[1] With or without side profile, see page A-24. - [2] With side profile, see page A-24. -
Device to be installed on a busbar Cut-out (c) for 1 device Cut-out (d) for 1 device
[b] [b] [b] (c)
DB425891.eps

DB425189.eps

DB425190.eps
DB425188.eps

48 55
X X X X X
DB425892.eps

185 196

27
32 27
63 54 63
70 54
Y
Z Y Y Y
Front connection of cables
FuPacT ISFT100N devices are equipped as standard Standard device
with connectors for bare copper cables from 2.5 to FuPacT connectors L (mm) 18
50 mm2 for mounting on backplates.
DB401307.eps

S (mm2) 2.5 to 50 rigid


Cu/Al 2.5 to 35 flexible
Torque (Nm) 3
[b] Laterally attachable support profile.

A-34
www.se.com
Dimensions and connection
FuPacT ISFT100
Dimensions

Dimensions
Device to be installed on a backplate or DIN rail
Fuse-carrier closed Front Fuse-carrier open

71 87
44

A
DB425127.eps

DB425128.eps

DB425765.eps
130 134
113 X X X

52.5 49
64.5
90

46 44.5
Z 46
89
176
Y Z

Feeding busbar for 2 ISFT100 Feeding busbar for 3 ISFT100 devices


devices

180 270

44.5 44.5
DB425134.eps

DB425135.eps

63.5 63.5

171.5 171.5
X X

64.5 64.5

Y Y

Feeding busbar for 4 ISFT100 devices

360

44.5
DB425136.eps

63.5

171.5
X

64.5

A-35
Dimensions and connection www.se.com

FuPacT ISFT100
Mounting and front panel cut-outs

Mounting
On backplate On a symmetrical DIN rail
50

25 Ø5
DB425191.eps

DB425137.eps

DB425138.eps
A
X X X
35

Y Z
Y

Front panel cut-outs


Cut-out for 1 device Cut-out for 2 devices

189
100

50 50
DB425139.eps

DB425192.eps

DB425193.eps

X 162 X X

77.5

Y
Y
46
Z

110
199
55
55
DB425194.eps

DB425195.eps

DB425196.eps

X 115 X 115 X
180 166

48 48
78.5
85.5

2 46
43
132
86
Y
Y

A-36
www.se.com
Dimensions and connection
FuPacT ISFT100
Connection and accessories

Front connection via bare cable connectors


FuPacT ISFT100 devices are equipped as standard with connectors for bare copper
or aluminium cables from 1.5 to 50 mm2 for mounting on backplates.
DB424800.eps

Standard device
FuPacT connectors L (mm) 18
S (mm2) 1.5 to 50 rigid
Cu/Al 1.5 to 35 flexible [1]

DB401307.eps
Torque (Nm) 3
A
Connection via bare cable connectors
3 x 10 mm² distribution connector
DB424801.eps

FuPacT connectors L (mm) 18


S (mm2) 1.5 to 10 rigid
DB401307.eps

Cu/Al 1.5 to 6 flexible [1]


Torque (Nm) 2 (cables)
3 (connectors)

[1] Connection of 2.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.

Front connection via feeding busbars


This accessory simplifies connection of cables and can be used to supply two to four
FuPacT ISFT100 devices.
bb Tightening torque 3 Nm.

Connection via feeding busbars

Incoming connector for feeding busbars


FuPacT connectors L (mm) 18
S (mm2) 25 to 95 rigid
Cu/Al 25 to 70 flexible
DB401307.eps

Torque (Nm) 10 (cables)


3 (connectors)
DB120516.eps

DB424946.eps

Distribution connector
DB425099.eps

Feeding busbars Figure 1 Figure 2


DB124587.eps

Incoming connector for feeding busbars

A-37
Dimensions and connection www.se.com

FuPacT ISFT100
Connection and accessories

Basic device with distribution connector option


14
25.5 25.5
DB425141.eps

DB425142.eps 88

A
X X
98
45

Z Y

Feeding busbars for two or three ISFT100 devices (with 25 to 95 mm² incoming connector)
90
DB425143.eps

DB425144.eps

DB425145.eps
44 25.5 25.5 180
14 25.5 25.5 90

110 107

X X X

Z Y
Y

Feeding busbars for four ISFT100 devices (with 25 to 95 mm² incoming connector)
DB425146.eps

90

180

270
Y

A-38
www.se.com
Dimensions and connection
FuPacT ISFT160
Dimensions

Dimensions
Fuse-carrier closed Front Fuse-carrier open
80 106
DB425132.eps

DB425766.eps
DB425133.eps
49 53
200
6 49
A

184
194 X 194 X X

267
97 92 97 105
133

[a]
6 50
Z

46
Z Y
[a] Terminal shields.

With hook-on With fuse monitor


114.5
DB425197.eps

DB425820.eps

49
24

60
6
214 X X

60

30 128

5... 10 Z
50

200
Z

A-39
Dimensions and connection www.se.com

FuPacT ISFT160
Mounting and front panel cut-outs

Mounting
On backplate

69 69 Ø 6.5
DB425767.eps

DB425768.eps

DB425199.eps
34.5 Ø7

A X
Ø7
X X
25

13 13 40
49 66 34.5

Y Y Y

On 60 mm busbars
With hook-on
DB430667.eps

6
X

Front panel cut-outs


DB425887.eps

DB425888.eps

DB425889.eps

X X 186 X

93

54
49 116
108
Z Y
Y

A-40
www.se.com
Dimensions and connection
FuPacT ISFT160
Connection and accessories

Front connection to standard M8 terminals


DB424803.eps

DB424804.eps
FuPacT ISFT160 devices are also equipped with 12 mm wide terminals with holes
for M8 screws for the connection methods presented below.
3 x 16 mm² distribution connector
L (mm) 25
S (mm2) 1.5 to 16 rigid

DB401307.eps
Cu/Al 1.5 to 10 flexible [1]
Torque (Nm) 2 (cables)
4 (connectors)
A
DB424806.eps

Used with long terminal shields


DB424805.eps

V-type connector for bare Cu/Al cables


L (mm) 25
S (mm2) 1.5 to 95 rigid
DB401307.eps

Cu/Al 1.5 to 70 flexible [1]


Torque (Nm) 4

Used with short terminal shields

Connector for flexible bars


DB424807.eps

DB425208.eps

L (mm) 20
l (mm) 12
DB401311.eps

e (Nm) 6
Torque (mm) 4

Used with short terminal shields

Lug for 95 to 185 mm² copper cables


L (mm) < 12
Ø (mm) 8.2
DB401312.eps

Torque (Nm) 14
DB425209.eps

DB120528.eps

L
Used with long terminal shields
Distribution connector V-type connector for bare [1] Connection of 2.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.
Cu/Al cables

Direct front connection to connectors


DB120456.eps

FuPacT ISFT160 devices are equipped as standard with connectors for bare copper
DB120529.eps

or aluminium cables from 1.5 to 50 mm2 for mounting on backplates.


Connector for flexible Lug for copper cables
bars Standard device
FuPacT connectors L (mm) 25
S (mm2) 1.5 to 95 rigid
DB120531.eps
DB425210.eps

DB401307.eps

Cu/Al 1.5 to 70 flexible


Torque (Nm) 4

Short terminal shield


Used with short terminal shields
Long terminal shields
DB124587.eps

Incoming connector for


feeding busbars

A-41
Dimensions and connection www.se.com

FuPacT ISFT160
Connection and accessories

Connections for mounting on a backplate


8 M5 33 33 M8

DB425212.eps
DB425211.eps

96
63

A 194
X
126
X

17 17

17
Z Y

Connections for mounting on 60 mm busbars


Hook-on connection

22
DB425823.eps

DB430668.eps

60 14 14
X X

60

37

50 Y
Z

A-42
www.se.com
Dimensions and connection
FuPacT ISFT250 to 630
Dimensions and mounting

Dimensions
Fuse-carrier closed Front Fuse-carrier open

P4 P5
DB425233.eps

DB425234.eps

DB425825.eps
P1

242 299 383

299 X X X

92
134
134 176 148

[a]
P3
Z

P2 L1
Z
L2
[a] Terminal shields.
Y

With hook-on for ISFT250/400/630 With fuse monitor for ISFT250/400/630


P7
DB425235.eps

DB425826.eps

P4 P1

242

299 9
X X

H1 92

121

28 P1 P3

Z
P6
Z
Type L1 L2 P1 P2 P3 P4 P5 P6 P7
ISFT250 92 184 70 70 74 112 293 316 142
ISFT400 105 210 90 90 94 131 331 319 162
ISFT630 125 250 90 90 94 131 332 319 162

A-43
Dimensions and connection www.se.com

FuPacT ISFT250 to 630


Mounting and front panel cut-outs

Mounting
On a backplate for ISFT250 On a backplate for ISFT400 On a backplate for ISFT630

150 166 195

DB425832.eps
DB425236.eps

DB425237.eps
75 Ø 11 83 Ø 11 97.5 Ø 11

A 25
50
X 25
50
X 25
50
X

Y Y Y

On busbars
With hook-on for ISFT250 With hook-on for ISFT400/630
DB425238.eps

DB425239.eps

14 60 100
X 14
X

60
100

Y Y

Front panel cut-outs


DB425881.eps

DB425882.eps

DB425883.eps

X X 301 X

135

L3 L3
P8
Y
Z L4

Y
Type L4 L5 P8
ISFT250 93 186 70
ISFT400 106 212 90
ISFT630 126 252 90

A-44
www.se.com
Dimensions and connection
FuPacT ISFT250 to 630
Connection and accessories

Front connection to standard M10 terminals


FuPacT ISFT250 to 630 devices are equipped as standard with terminals comprising
DB425240.eps

holes for M10 screws for the connection methods presented below.

V-type connector for bare Cu/Al cables


ISFT250 ISFT400/630
L (mm) 20 25

DB401307.eps
S (mm2) 6 to 150 6 to 240
Cu/Al
Torque (Nm) 14 14
A
Connector for flexible bars
ISFT250 ISFT400/630
L (mm) 20 30
DB401311.eps

I (mm2) 16 21
e (mm) 15 15
Torque (Nm) 14 14
DB425241.eps

Lug for 100 to 185 mm² copper cables


ISFT250 to 630
Terminal shields L (mm) y 16
DB401312.eps

Ø (mm) 10.2
Torque (Nm) 32
DB124900.eps

V-type connector Lug for 240 to 300 mm² copper cables


ISFT400/630
L (mm) y 21
DB401312.eps

Ø (mm) 10.2
Torque (Nm) 32

L
DB124901.eps

Connector for flexible bars


DB120456.eps

Lug for copper cables

A-45
Dimensions and connection www.se.com

FuPacT ISFT250 to 630


Connection and accessories

Connections for mounting on a backplate


A A B
DB425242.eps

DB425243.eps
C
A
X X
D

Y Z

Type A B C D
ISFT250 57 33 93 186
ISFT400 65 36.5 104.5 209
ISFT630 80 36.5 104.5 209

Connections for mounting on 60 mm busbars


Hook-on connection for ISFT250/400
28
DB425244.eps

DB425245.eps

60 9
X X
D
60

5... 10 B A A

Z Y

A-46
www.se.com
Wiring diagrams
FuPacT ISFT

Power

DB423470.eps
FU01 FU02 FU03

A
Auxiliary contacts
ISFT100N ISFT100 to 630

DB423472.eps
DB423471.eps

Blown fuse
ISFT160 to 630 Electronic fuse
Monitor
DB423479.eps

22
21
14
13

A-47
www.se.com

D
B

ISFL160 ISFL250/400/630/1250

2
www.se.com

FuPacT ISFL

Functions and characteristics


Fuse switch-disconnector selection..................................B-4
FuPacT ISFL160 to ISFL1250.......................................................... B-4

Accessories and auxiliaries..................................................B-8


FuPacT ISFL160 - 3P....................................................................... B-8
FuPacT ISFL250 to ISFL630.......................................................... B-10
FuPacT ISFL1250........................................................................... B-11

General characteristics: ISFL............................................ B-12


FuPacT ISFL160 to ISFL1250........................................................ B-12 B
ISFL installation...................................................................... B-14
FuPacT ISFL160............................................................................. B-14
FuPacT ISFL250 to ISFL1250........................................................ B-15

Connection and accessories ........................................... B-16


FuPacT ISFL160 to ISFL1250 - Connection................................... B-16
FuPacT ISFL160 to ISFL630 - Connection, coupling ................... B-18
FuPacT ISFL160 to ISFL630 - Reverse distribution....................... B-20
FuPacT ISFL1250 - Reverse distribution....................................... B-21

Insulation ................................................................................. B-22


FuPacT ISFL160 to ISFL630.......................................................... B-22
FuPacT ISFL250 to ISFL1250........................................................ B-23

Fuse monitor........................................................................... B-24


FuPacT ISFL160 to ISFL1250........................................................ B-24

Measurement accessory.................................................... B-26


FuPacT ISFL160 to ISFL1250........................................................ B-26

Fuse-link monitoring and testing..................................... B-28


FuPacT ISFL160 to ISFL1250........................................................ B-28

Control, locking and operation......................................... B-29


FuPacT ISFL160 to ISFL1250........................................................ B-29

Auxiliary contacts and indications.................................. B-31


FuPacT ISFL160 to ISFL1250........................................................ B-31
FuPacT ISFL160 to ISFL630.......................................................... B-32
FuPacT ISFL1250........................................................................... B-33

Intelligent measurement..................................................... B-34


FuPacT ISFL160 to ISFL630.......................................................... B-34

Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1

B-1
www.se.com

FuPacT ISFL

Installation recommendations
Possible installation positions and mounting ............. B-36
FuPacT ISFL160 to ISFL1250........................................................ B-36

Implementation and power dissipation......................... B-37


FuPacT ISFL................................................................................... B-37

Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1

B-2
www.se.com

FuPacT ISFL

Dimensions and connection


FuPacT ISFL160 3 x 1P....................................................... B-39
Dimensions and mounting.............................................................. B-39

FuPacT ISFL160 1 x 3P....................................................... B-41


Dimensions and mounting.............................................................. B-41
Connection and accessories.......................................................... B-43

FuPacT ISFL250 to 630 1 x 3P ........................................ B-44


Dimensions and mounting.............................................................. B-44

FuPacT ISFL250 to 630 ..................................................... B-45 B


Dimensions and mounting.............................................................. B-45

FuPacT ISFL1250 ................................................................ B-46


Dimensions and mounting.............................................................. B-46
Connection and accessories.......................................................... B-48

Wiring diagrams
FuPacT ISFL........................................................................... B-49

Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT GS.................................................................................................C-1
Catalog numbers........................................................................................D-1

B-3
Functions and characteristics www.se.com

Fuse switch-disconnector selection


FuPacT ISFL160 to ISFL1250

Fuse switch-disconnectors
Number of poles / type of fuse-link IEC60 269-2-1 Section 1
Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3 and
PB113883-R8.eps

EN 60947-1 / EN 60947-3
Conventional thermal current (A) In free air Ith at 40 °C
Maximum fuse power dissipation (W)
In enclosure Ithe at 40 °C
Maximum fuse power dissipation (W)
Rated insulation voltage (V) Ui AC 50/60 Hz / DC
Rated impulse withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
Rated operational voltage AC20 and DC20 (V) Ue
Rated operational current (A) Ie AC 50/60 Hz
220/240 V

B 380/415 V
PB107274_11.eps

440/480 V [1]
500 V
660/690 V
DC/poles in series
125 V /nbr of poles
220 V /nbr of poles
440 V /nbr of poles
Rated duties Uninterrupted duty
ISFL160 - 3P ISFL160 - 3 x 1P Rated short-circuit breaking capacity (kA rms)/ Icn/Icm/In 415 V
Rated short-circuit making capacity (kA peak)/ 500 V
Fuse-link In (A) [2]
690 V
Endurance (category B) (CO cycles) Mechanical
Electrical AC AC23B 415 V
PB113884-R10.eps
PB107275_20.eps

AC22B 500 V
AC21B 690 V
Suitability for isolation
Positive contact indication
Pollution degree
Control
Direct handle (operator-dependent opening and closing)
Locking Padlocks
Lead seal
Indication auxiliaries
Auxiliary contacts
Current transformer
Installation and connection accessories
Possible mounting position Horizontal
Vertical
Connector For bare Cu/Al cables
For flexible bars
Lugs for Cu/Al cables
Terminal shields
Dimensions and weight
Overall dimensions H x W x D (mm) 3P
Approximate weight without fuse-links (kg) 3P
[1] Suitable for 480 V NEMA.
ISFL250 - 3P ISFL250 - 3 x 1P [2] Fuse-switch disconnectors with fuse-links.
[3] Only for ISF160 with direct connection to the busbars.
[4] AC22B 690 V.

B-4
www.se.com Functions and characteristics

Fuse switch-disconnector selection


FuPacT ISFL160 to ISFL1250

ISFL160 ISFL250 ISFL400 ISFL630 ISFL1250


3 x 1P or 3P/DIN (NH) 3 x 1P or 3P/DIN (NH) 3 x 1P or 3P/DIN (NH) 3 x 1P or 3P/DIN (NH) 3P/DIN (NH)

160 250 400 630 1250


12 23 34 48 2 x 48
160 250 400 630 1250
12 23 34 48 2 x 48
1000 1000 1000 1000 1000
8 8 8 8 8
690 690 690 690 690
800 800 800 800 800
AC22B AC23B AC21B AC22B AC23B AC21B AC22B AC23B AC21B AC22B AC23B AC21B AC22B
160 160 250 250 250 400 400 400 630 630 630 1250 1250
160
160
160
-
250
250
250
250
250
-
400
400
400
400
400
-
630
630
630
630
630
-
1250
1250
1250
1250
B
160 - 250 250 - 400 400 - 630 630 - 1250 1250
100 - 250 - - 400 - - 630 - - 1250 -
DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B DC21B DC22B
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -

100 / 210 / 160 120 / 250 / 250 120 / 250 / 400 120 / 250 / 630 120 / 250 / 630
100 / 210 / 160 120 / 250 / 250 120 / 250 / 400 120 / 250 / 630 120 / 250 / 630
100 / 210 / 160 100 / 210 / 200 100 / 210 / 315 100 / 210 / 500 100 / 210 / 500
1400 1400 800 800 800
200 200 200 200 200
200 [4] 200 200 200 200
200 200 200 200 200

3 3 3 3 3

- - - - -

[3]

- - - -

- - - -
- - - -
included included included included included

405 x 50 x 123 741 x 100 x 190 741 x 100 x 190 741 x 100 x 190 834 x 200 x 190
1.30 4.70 5.00 5.60 15.20

B-5
Functions and characteristics www.se.com

Fuse switch-disconnector selection


FuPacT ISFL160 to ISFL1250

Fuse switch-disconnectors
PB113883-R8.eps
Type of fuse-link
DIN NH000
DIN NH00
DIN NH1
DIN NH2
DIN NH3
Installation and connection
ISFL160 for 60 mm busbar hook-on contact mounting with multiple use terminal (screw M8)
ISFL160 for 60 mm busbar hook-on contact mounting with box terminal 95 mm2
ISFL160 for 100 mm busbar hook-on contact mounting with multiple use terminal (screw M8)
PB107274_11.eps

ISFL160 for 100 mm busbar hook-on contact mounting with box terminal 95 mm2

B Conversion kit for 185 mm busbar direct contact mounting (for 1 or 2 x ISFL160)
ISFL160 for 185 mm busbar 1-pole switchable direct mounting
ISFL160 for 185 mm busbar 1-pole switchable hook-on mounting
Terminal tightening torque (Nm)
Temperature derating (with gG fuse-link) [1]
“Vertical mounting” Ith (A) 40 °C
fuse-links in vertical position 45 °C
50 °C
ISFL160 - 3P ISFL160 - 3 x 1P 55 °C
60 °C
65 °C
70 °C
“Horizontal mounting” Ith (A) 40 °C
fuse-links in horizontal position 45 °C
50 °C
55 °C
PB113884-R10.eps

60 °C
PB107275_20.eps

65 °C
70 °C
[1] Derating data is based on:
- the maximum rating for fuse-links intended for the device
- maximum power dissipation.

ISFL250 - 3P ISFL250 - 3 x 1P

B-6
www.se.com Functions and characteristics

Fuse switch-disconnector selection


FuPacT ISFL160 to ISFL1250

ISFL160 ISFL250 ISFL400 ISFL630 ISFL1250


- - - -
- - - -
- - - -
- - - -
- - -

- - - -
- - - -
- - - -
- - - -
- - - -
B
see page B-4

160 250 400 630 1250


150 240 380 600 1200
145 225 360 570 1130
135 215 340 535 1070
130 200 320 500 1000
120 190 300 475 940
110 175 280 440 880
160 - - - -
150 - - - -
145 - - - -
135 - - - -
130 - - - -
120 - - - -
110 - - - -

B-7
Functions and characteristics www.se.com

Accessories and auxiliaries


FuPacT ISFL160 - 3P

A B C D
DB430689.eps

I E

H G F

A NO + NC auxiliary changeover contacts E Connectors for : H Fuse monitor


b bare cable
B Lenght adapter I Current transformer
b flexible bars
C Side cover for front panel cut-out F Lenght adapter J Conversion kit for direct connection to
185 mm busbars
D Blank panel cover for free slot G Lug for copper cable
B-8
www.se.com Functions and characteristics

Accessories and auxiliaries


FuPacT ISFL160 - 3 x 1P

A B C D
DB430657.eps

F E

A Current transformer E Connectors for :


b bare cable
B NO + NC auxiliary changeover contacts
b flexible bars
C Side cover for front panel cut-out F Lug for copper cable
D Blank panel cover for free slot G Hooks
B-9
Functions and characteristics www.se.com

Accessories and auxiliaries


FuPacT ISFL250 to ISFL630
DB430690.eps

A B

B J

x3

H G F E

A NO + NC auxiliary changeover contacts E Screws with plastic support H Lug for copper cable
B Empty plastic box F Connector for Cu/Al bare I Current transformer
cables 2 x 50 to 185 mm2
C Blank panel cover for free slot J Hooks
G Connector for Cu/Al bare
D Side cover for front panel cut-out
cables 1 x 35 to 300 mm2
B-10
www.se.com Functions and characteristics

Accessories and auxiliaries


FuPacT ISFL1250

A
DB430691.eps

G B

E D C

A NO + NC auxiliary changeover contacts E Lug for copper cable


B Blank panel cover for free slot F Current transformer
C Side cover for front panel cut-out G Hooks
D Connector 4 x 240 mm 2

B-11
Functions and characteristics www.se.com

General characteristics: ISFL


FuPacT ISFL160 to ISFL1250

With FuPacT ISFL, you have one of the most efficient vertical NH fuse switch-
disconnectors ever designed with compact dimensions, a modular system and an
elegant design. Your benefit are as follows:

Future proof
The trend is moving from simple power distribution stations to more intelligent power
distribution stations. FuPacT ISFL is made for the future: with interfaces for
measurement and control equipment which can be integrated in a space-saving
manner.
PB107611_60mm.eps

B Reduced heat development


Safeguarding high currents requires one thing above all: keeping a cool head.
This is where FuPacT ISFL leads the pack. They feature one of the lowest heat
development values of all products available on the market. This pays off for your
entire facility: reduced energy loss, improved operating safety and durability.

ISFL turnable hooks


Faster mounting
All installation and connecting components of the FuPacT ISFL were optimized and
the number of assembling steps was reduced.
This puts your switch “on the track” even more quickly.

Safety in mind
The switch gears are very user friendly and provide optimal user protection due to
parallel switching. Two disconnected positions per phase produce two smaller
electrical arcs. This causes only half the arc voltage.

Turnable contact hooks


FuPacT ISFL fuse-switches, vertical design, 00/60 are the first of its kind to feature
turnable contact hooks. This makes it much easier to mount the NH Fuse-Switch on
the busbar in addition to being much more flexible. Due to its symmetry, the NH
Fuse-Switch can be turned around at any time. Terminal top or bottom can be
chosen freely. Thus, only one version needs to be placed on stock.

Fast connection – with variable box terminals


High currents require large cable cross-sections. At the same time, modern
switchboard cabinets are becoming more and more compact.
They accommodate three cables of up to 95 mm² in the smallest possible. No one
else can do that with a FuPacT ISFL 160 A. This is possible only due to the stepped
and slightly offset arrangement of the box terminals. Captive screws enable a quick
and reliable securing of the cable.

Optimized back-up with space-saving current-


transformer installation
Do you wish to measure currents in addition to safeguarding them? We have
redefined space for you. Our new current transformers can be installed
behind the FuPacT ISFL, vertical design, without an alteration of installation depth.
After removing the break-out-pieces form the socket, the current transformers is
simply plugged on – ready for use. With or without a current transformer,
the FuPacT ISFL always has the same installation depth, so no adaptors are
required.

B-12
www.se.com Functions and characteristics

General characteristics: ISFL


FuPacT ISFL160 to ISFL1250

The elegant solution


To obtain the same installation depth with surrounding devices, the FuPacT ISFL
vertical design, size 00/185 does not only come with conventional adapters but also
features raised busbar connections. This makes it easy to mount the fuse-switch
adjacent to devices of size 1 to 3. Simply hook the elevated feeding bracket onto the
pre-mounted bolts or attach it with the contact hooks.
There is no need for drilling. This allows the same installation depth for all sizes,
giving the front face a clear uniform look.

No trouble with large cross-sections

PB115409_L31.eps
Standard universal terminals allow the direct connection of cable lugs as well as
cables with cross-sections up to 300 mm2. Easy-to-install terminal hardware gives
B
you great flexibility. No other small-sized FuPacT ISFL can do that.

Appealing at first sight


Rotating nameplates turn your installation possibilities into a real eye-catcher. No
matter if the terminal is located on top or at the bottom, technical data and installation
labels of all FuPacT ISFL are always correctly aligned.

Turn-off-position – up to three padlocks


Even fuse-protection-devices need to be protected: from electricity-theft,
manipulation and unauthorized use. This is why every 3-pole FuPacT ISFL, vertical
design, may be locked with up to three locks. This is possible in both, the closed and FuPacT ISFL160 - 3 x 1P
the secure padlock position.

Intelligent measurement
The future belongs to more intelligent switchboards. FuPacT ISFL is well prepared
for the future: it offer standardized interface for measurement devices.
Contemporary power management
FuPacT ISFL measuring devices offers a large selection of measuring and
monitoring options: from basic current measurements and power metering,
harmonic wave analysis to remote management and alarm relays, and many more.
All electrical parameters are visualized on an LCD and can be centralized. EM
measuring devices are normally installed separately in the switchboard. FuPacT
ISFL offer an integrated solution which can simply be plugged on.
Electronic Fuse-Monitoring - Everything under control
You know what happens and where it happens almost instantly to a notification,
technician receives the information required to precisely locate and quickly correct
short-circuits and overloads. Your technician will be faster to analyze and change
fuse which is broken.
PB107276.eps

FuPacT ISFL630 with fuse monitor

B-13
Functions and characteristics www.se.com

ISFL installation
FuPacT ISFL160

FuPacT ISFL fusegear is installed vertically and connected directly to the busbars.
The connection is bolted or could be made by the hook-on connection.

ISFL160 fusegear
Connection to busbars.
The power circuit is connected:
bb directly to the 100 mm busbars for 3-pole version or to the 185 mm busbars for
1-pole version
bb using a hook-on connection to 60 mm busbars (3-pole version)
bb via a conversion kit for connection to 185 mm busbars (3-pole version)
bb via a conversion kit for two devices and for connection to 185 mm busbars.
PB115408_L32.eps

Downstream connection of distribution circuits requires cables (3-pole version).

B
DB423382.eps

DB423383.eps

Direct connection to the busbars


(ISFL160 and ISFL400)
DB423385.eps
DB423384.eps

B-14
www.se.com Functions and characteristics

ISFL installation
FuPacT ISFL250 to ISFL1250

ISFL250/400/630 fusegear
Connection to busbars.
The power circuit is connected:

DB423386.eps
bb directly to the 185 mm busbars for 1-pole and 3-pole version
bb using a hook-on connection to 185 busbars

Direct connection to the busbars:


the device is bolted to the busbars with
one connection point per phase that allows
for both electrical connection and robust
B
DB423388.eps

DB423389.eps

mechanical mounting.

DB423387.eps
Hook-on connection to busbars:
the device tightly hooks on to the
busbars via three hooks that allows for
both electrical connection and robust
mechanical mounting.

These two systems allow for or enable


direct contact of the power circuit to
the busbars and usual connections for
downstream distribution (bare cable
connectors, lugs, bars, distribution
connectors, etc.).

ISFL1250 fusegear The two connection systems can also be


Connection to busbars. reversed to supply distribution circuits via
The power circuit is connected: the upstream terminals.
bb directly to the 185 mm busbars for 3-pole version
bb using a hook-on connection to 185 mm busbars
DB423390.eps

DB423391.eps

B-15
Functions and characteristics www.se.com

Connection and accessories


FuPacT ISFL160 to ISFL1250 - Connection

FuPacT ISFL fuse-switch disconnectors can supply distribution circuits via either the upstream or downstream
terminals.
Devices intended for connection to busbars are configured as standard for distribution via the downstream terminals.

ISFL fusegear is equipped with connectors or terminals for front connection of:
bb cables with lugs for the ISFL160 and ISFL1250 devices
bb flexible bars for the ISFL160 devices
bb bare cables for ISFL160 to 630 devices.

ISFL160 ISFL250 ISFL400 ISFL630 ISFL1250


Cables
Lug 95 mm2 -
- -
Cable connector to terminal 1.5 to 95 mm2 1 x 35 to 300 mm2 -
B Flexible bars
- 2 x 50 to 185 mm2

Connector 12 x 6 mm - - - -

ISFL160 fusegear [1]


DB423396.eps

DB423397.eps
62330a_1-2_15.eps

Lug for copper cables


62323a_3.eps

Connector for bare Cu/Al cables


62324a_3.eps

Connector for flexible bars

[1] Connections and accessories are identical for ISFL single phase.

B-16
www.se.com Functions and characteristics

Connection and accessories


FuPacT ISFL160 to ISFL1250 - Connection

ISFL250/400/630 fusegear [1]

62330a_1-2_15.eps
DB423398.eps

DB423399.eps

DB423400.eps

DB402725.eps
Connector for Cu/Al bare cable 1 x 35 to 300 mm²

PB101086-22.eps

or

Connector for Cu/Al bare cable 2 x 50 to 185 mm²


DB402726.eps

ISFL1250 fusegear
DB423401.eps

DB423402.eps

Connector for cables with lugs


PB115680_68.eps

Connector 4 x 240 mm2

[1] Connections and accessories are identical for ISFL single phase.

B-17
Functions and characteristics www.se.com

Connection and accessories


FuPacT ISFL160 to ISFL630 - Connection, coupling

Two conversion kits are available for ISFL160 3-pole switchable to adapt the 100 mm standard fixing centres to
185 mm fixing centres.

Direct connection to 185 mm Conversion from 100 to 185 mm


busbars The kit connects to the busbars via a hook-on connection.
Conversion kit for 185 mm busbars includes electrical and mechanical connections
to the busbars (set of nuts and bolts).
Electrical and mechanical connection of the device to 100/185 mm conversion kit is
ensured by three screws.
DB423403.eps

B
DB423404.eps

DB423405.eps
185

185
185

185

185
185

ISFL160 1P
PB107282_10.eps

PB107283_19.eps

ISFL160 (185 mm kit)

B-18
www.se.com Functions and characteristics

Connection and accessories


FuPacT ISFL160 to ISFL630 - Connection, coupling

Installation of devices with different ratings on a given set of busbars

DB423407.eps
DB423406.eps

Coupling kit from ISFL250 to ISFL630


DB425713.eps

> Instruction sheet

QGH568500

B-19
Functions and characteristics www.se.com

Connection and accessories


FuPacT ISFL160 to ISFL630 - Reverse distribution

ISFL160 fusegear devices with hook-on connection to 60 mm bars are available in


PB115408_L32.eps

two versions:
bb connection using M8 screws
bb connection using a 95 mm2 terminal.
For each of these versions, the distribution reversal mode is achieved by rotating the
hooks located at the rear, which gives the possibility of upstream distribution.
The fuse-carrier assembly does not change position.
All the various connection modes could be reversed also.

ISFL160 fusegear with turnable hooks [1]

B
DB423408.eps

Direct connection on 185 mm busbar


(ISFL160 with ISFL630)

ISFL250/400/630 fusegear [1]


ISFL160 release tab
b To remove the fuse-carrier assembly from
the base, put the device in open position
and press the release tab down.
DB423409.eps

b To lock the fuse-carrier assembly, replace


it in open (OFF) position on the base and
push the release tab up.

ISFL250/400/630 release tab


b To remove the fuse-carrier assembly from
the base or install it on the base, check that
the device is in open position and press the
release tab down.
b To lock the device in open (OFF) position,
push the release tab up.

[1] For ISFL 1-pole switchable: identical reversed distribution could be done.

B-20
www.se.com Functions and characteristics

Connection and accessories


FuPacT ISFL1250 - Reverse distribution

ISFL1250 fusegear devices can be reversed to allow an upstream distribution.


ISFL1250 fusegear
DB423410.eps

B-21
Functions and characteristics www.se.com

Insulation
FuPacT ISFL160 to ISFL630

ISFL160 fusegear
PB107288_24.eps

DB423411.eps

DB423412.eps
Length adapter

B
PB107286_10.eps

PB107287_18.eps

Sideframe door Sidewise angle bracket


cut out for side frame
DB423414.eps
DB423413.eps

B-22
www.se.com Functions and characteristics

Insulation
FuPacT ISFL250 to ISFL1250

ISFL250/400/630 fusegear [1]


DB423415.eps

DB423416.eps

PB107289_6.eps

PB107295_9.eps
B
Blank panel cover

[1] Accessories are identical for ISFL 1-pole switchable.

ISFL1250 fusegear
DB423418.eps
DB423417.eps

B-23
Functions and characteristics www.se.com

Fuse monitor
FuPacT ISFL160 to ISFL1250
PB107278_11.eps

Functions
The device provides remote indication of the standard fuse status (without strikers).
It is used to:
bb signal a blown fuse
bb protect motors from overloads caused by single-phase operation.

Standards
bb Compliance with international standard IEC 60947-5-1.
bb Compliance with:
vv EN 50204
vv EN 61000 for electromagnetic compatibility (EMC).

Description
B bb Fuse monitor function only for 3P.
bb Operation with DIN fuses.
bb May be used on capacitor bank circuits.
bb Simplified power supply:
vv does not require a specific power supply
PB107276_20.eps

vv operates with unbalanced phases


vv supplied via connection to the fuse terminals on the switch-disconnector fuse
vv operational voltage 400...690 V AC, ±10 %, 50/60 Hz.
bb Tested for electromagnetic compatibility (EMC).
bb ISFL160:
vv it is a fuse-carrier/handle and fuse monitor sub-assembly supplied as a kit
composed of:
- fuse monitor equipped with one NO contact and one NC contact
- fuse-carrier with the handle
bb ISFL250 to 1250:
vv order directly the fuse monitor mounted on the product
bb Characteristics:
vv IP20 degree of protection
vv To have a complete class II insulation, install the product with a fuse monitor
inside a switchboard and not on the front face.
Class II insulation with switchboard on front face is ensured only when FuPacT ISFL
is in closed position.
Note: lugs for connection to the fuse-carrier are not supplied.

Operation
Reset
The device is automatically reset when the fuse-links are replaced.
Indications
bb Normal operation:
vv the green LED is ON when voltage is present at the fuse terminals
vv the contacts are in the rest position
PB119108.eps

bb Operation when a fuse is blowed:


vv the green LED goes off and the red LED goes on
vv the contacts are actuated:
- the NO contact is for remote fault indication
- the NC contact may be used, for example, to control an undervoltage device
in order to shut down equipment that may be sensitive to single-phasing.

B-24
www.se.com Functions and characteristics

Fuse monitor
FuPacT ISFL160 to ISFL1250

Electrical characteristics
Power circuit
Rated operational voltage (Ue) 400 to 690 V AC 50/60 Hz ±10 %
Consumption < 3 VA
Rated frequency 50/60 Hz
Measurement impedance > 1000 W/V
Rated impulse withstand voltage (1.2 / 50 ms) (Uimp) 8 kV
Auxiliary contact output terminals
Terminal indications NO 13 - 14
NC 21 - 22
Cable capacity Flexible y 1.5 mm2 Cu
Rigid y 2.5 mm2 Cu
Output contact characteristics (1NO + 1NC)
Conventional thermal current Ith (A)
Rated insulation voltage (V)
5
250 B
Minimum load 10 mA at 24 V
Characteristics AC DC
Utilisation category (IEC 60947-5-1) AC12 AC15 DC12 DC13
Operational current (A) 24 V - 3 - 2
48 V - 3 - -
110 V - 3 - -
220/240 V - 3 - -
250 V - 3 - -
380/415 V - - - -
440 V - - - -
660/690 V - - - -
Rated operational voltage / max. breaking voltage (V AC) 250/440
Breaking capacity (VA) 2000

General characteristics
Operating temperature range (°C) -25…+55 (y 500 V) -25…+45 (> 500 V)
Storage and transport temperature range (°C) -40…+70
Fuse blowing detection time (s) <2
Overvoltage category / degree of pollution IEC 60947-1 3
Dielectric test voltage (between power circuit and output terminals) 5 kV rms / 1 min 50 Hz
Electromagnetic compatibility - emission
Conducted EN 55022 Class B
Radiated EN 55022 Class B
Harmonic currents EN 61000-3-2 Class A
Electromagnetic compatibility - immunity
Electrostatic discharge (ESD) EN 61000-4-2 category B level 2/3
Radiated field susceptibility (RF) EN 61000-4-3 category A level 3
Surge immunity test EN 61000-4-5 level 4
Conducted low energy susceptibility (EFT) EN 61000-4-4 category B level 3
Conducted high energy susceptibility (RF) EN 61000-4-6 category A level 3
Radio-frequency interference (GSM) ENV 50204 category A
Magnetic field immunity
Continuous EN 61000-4-8 level 5

Mechanical characteristics
Degree of protection IP20
Weight (fuse monitor alone) (kg) 0.2
Dimensions

33
DB425712.eps

83

45

B-25
Functions and characteristics www.se.com

Measurement accessory
FuPacT ISFL160 to ISFL1250

The current transformers (CTs) produce a current (1 - 5 A) on the secondary winding that is proportional to the
current measured on the primary winding.
They can therefore be used in conjunction with measurement devices (ammeters, energy meters), load-shedding
devices, control relays, etc.

Operation and implementation


FuPacT ISFL160 to 1250 fusegear can be equipped with tube-unit current
transformers (CT).
CT modules are available in two versions:
bb 3-pole module with one or three CTs for ISFL160 fusegear (3-pole version),
1 rating 150 A.
bb single-pole module with one CT for ISFL160 (1-pole version) /250/400/630/1250.
bb fusegear, 4 ratings from 150 to 600 A.
B The CT modules are clipped onto the back of the switchgear.
The modules can be connected:
bb via terminal blocks for the 3-pole modules (ISFL160) with output current of 1 A.
bb via cables directly connected with output current of 5 A.
bb via lugs for the single-pole modules (ISFL 160 (1 pole version)/250/400/630/1250).

Selection table
PB107279_15.eps

ISFL160
class 1
1-pole version
Ip/5 Ip/1 Power (VA)
150/5 - 5
ISFL160 accuracy class 1 ISFL250 to 1250 class 1
3-pole version 1 and 3-pole version
Ip/5 Ip/1 Power (VA) Ip/5 Power (VA)
1 1
150/5 - 1.5 150/5 2.5
PB113887-R5.eps

250/5 5
150/1 2.5 400/5 5
600/5 5
Curent transformer
for ISFL160
(1-pole version) Environment
bb Compliance with standards: IEC 60044-1, NFC 42502, VDE 0414, BS 7626 and
IEC 60038-1.
bb Degree of protection: IP20.
bb Operating temperature range: -25 °C to +70 °C, relative humidity 95 %.
PB107281_18.eps

bb Storage temperature range: -40 °C to +80 °C.

Technical characteristics
Single block current Current transformer for CT electrical characteristics:
transformer for ISFL160 ISFL250/400/630/1250 bb maximum operational voltage: 800 V
(1 or 3 CTs) bb secondary current: 5 A and 1 A
bb frequency: 50 to 60 Hz
bb continuous overload current: 1.2 In
bb safety factor: Fs y 5.
Transformation ratio:
bb Ip/5 A.
Select the ratio just above the measured current (In).
Example: In = 550 A V select a ratio of 600/5.
CT accuracy class:
bb the accuracy class depends on the transformer rating and the consumption of the
measurement system. Consumption must take into account the devices and cables
bb for a given accuracy class, measurement system consumption must not exceed
the transformer rating.
Reminder:
Transformer secondary must be short-circuited before any work.

B-26
www.se.com Functions and characteristics

Measurement accessory
FuPacT ISFL160 to ISFL1250

CT accuracy class
Measurement system

PB107336_13.eps

PB107335_13.eps
Schneider Electric device Consumption in VA
72 x 72 mm ammeter 1.1
Analogue ammeter 1.1
Digital IM ammeter 0.5
Digital ammeter 0.3
PM/CM Power Meter
PM9
0.15
0.55
B
Primary copper cross-section Rating in VA per meter of double wire
in mm² at 20 °C
1 1
1.5 0.685
2.5 0.41
4 0.254
6 0.169
10 0.0975
ISFL160 (with CT)
For each ten-degree increase in temperature, the power drawn by the cables
increases by 4 %.

Example of measurement system consumption at 40 °C


4 m of 2.5 mm2 double wire 1.7 VA ISFL250/400/630 (with CT)
PM + 0.15 VA
Total consumption = 1.85 VA

CT accuracy class
The accuracy class of the CT is determined:
PB112100-B_26.eps

bb using the selection table


bb by the fact that consumption must be < the transformer rating:
vv class 1 for a CT with a ratio of 150/5
vv class 0.5 for a CT with a ratio of 200/5.
If measurement accuracy must be within 0.5 %, it is necessary to select a CT
with a transformation ratio of 200/5.

ISFL250 (with CT)

B-27
Functions and characteristics www.se.com

Fuse-link monitoring and testing


FuPacT ISFL160 to ISFL1250

Monitoring
ISFL fuse-switch disconnectors are equipped with large windows so that the
fuse-link technical characteristics are clearly visible.

DB423419.eps

B
PB107611_30.eps

ISFL160

Testing
DB423420.eps

Sliding covers on the front panel provide access to the fuse-link status test points
while maintaining the IP20 protection index.

Note: monitoring and testing functions are the same for ISFL 1 pole switchable.

B-28
www.se.com Functions and characteristics

Control, locking and operation


FuPacT ISFL160 to ISFL1250

The main moving contacts are controlled by the drawout fuse-carrier assembly for the ISFL devices.
In open position, the fuse-switch disconnector fuse-carrier assembly provides isolation with visible break.

Control Removed sub-assembly [1]

PB107611_30_r.eps
DB423421.eps

DB423422.eps

ISFL160

To indicate isolation at a glance during


maintenance operations for example, put
the ISFL fuse switch-disconnector in the
"PARK" position by pressing the lock on the
[1] Except for ISFL1250. front of the product.
In this position, the handle is free and the
Locking ON [2] Locking OFF [2] fuses are physically separated from the
contacts.
DB120140.eps

DB120140.eps

The product can then be padlocked


ON OFF (3 x Ø6 mm padlocks for ISFL160
and Ø8 mm for other ISFL).
Press the lock again to close the product
when the padlocks have been removed.
Another solution is to remove the upper
sub-assembly by pressing the lock in the
DB423423.eps

DB423424.eps

"OUT" position. Then, the sub-assembly


must be reversed and put directly on the
product.

Access to the fuse-links:


b is automatically blocked on the ISFL
devices when the fusegear is closed
b may be restricted using padlocks on the
ISFL devices.

To lock the fuse-switch disconnector in


closed (ON) or open (OFF) position, the
fuse-carrier is equipped with lead-seal or
padlocking accessories (not supplied).
Padlocking for the ISFL160 to ISFL630 devices

[2] Except for ISFL160 - 1P to ISFL630 - 1P.

Locking in open (OFF) position provides isolation as defined by IEC 60947-3.


Type Function Means Accessory
ISFL160 Device locking in closed (ON) Padlocks 3 max Ø6 Built-in
ISFL250 to ISFL1250 or open (OFF) position Padlocks 3 max Ø8

B-29
Functions and characteristics www.se.com

Control, locking and operation


FuPacT ISFL160 to ISFL1250

For FuPacT ISFL fusegear devices, the fuse-carrier assembly is used both to control the device and to mechanically
protect the fuse-link.

Fuse-carriers [1]
Compatibility between ISFL fuse-switch disconnectors
and fuse-links (NH)
PB107611_30.eps

DB423425.eps

Drawout fuse-carrier assembly for the ISFL160 to 1250 devices

ISFL160
Type of DIN NH000 NH00 NH1 NH2 NH3
fuse-link
ISFL160 - - -
ISFL250 - - - -
ISFL400 - - - -
ISFL630 - - - -
ISFL1250 - - - -

Insertion and removal of fuse-links


Fuse-links are held in place by clips behind the front panel of the fuse-carriers, thus
making removal possible without touching the fuse-links.
DB423426.eps

ISFL160 and ISFL250 to ISFL1250

[1] Control, locking and operation are the same for ISFL 1-pole switchable.

B-30
www.se.com Functions and characteristics

Auxiliary contacts and indications


FuPacT ISFL160 to ISFL1250

The optional auxiliary contacts carry out indication functions.


They provide remote indication of the fuse-switch disconnector status. They may
also be used to indicate and carry out automatic functions such as electrical

62325a_1-29.eps
interlocking.

Standards: compliance with international recommendation IEC60947-5-1.


Description: NC/NO changeover contact.
Auxiliary contact for ISFL160
Functional table of contact status
Auxiliary changeover contact B
Maximum number

ISFL160 2

PB107277_25_r.eps
ISFL250 4
ISFL400 4
ISFL630 4
ISFL1250 8

Auxiliary changeover contact for ISFL160 to 1250 ISFL250/400/630/1250


Rated thermal current Ith (A) 2
Rated insulation voltage (V) 250
Minimum load 100 mA at 24 V
AC12 DC12
Operational current (A) 24 V 2 0.2
48 V 2 0.2
110 V 2 0.2
220/240 V 2 0.2

B-31
Functions and characteristics www.se.com

Auxiliary contacts and indications


FuPacT ISFL160 to ISFL630

Position of auxiliary contacts for ISFL devices


ISFL160 ISFL250/400/630
62325a_1-29.eps

DB423427.eps

DB423428.eps
B

Auxiliary contact for ISFL160


PB107277_25_r.eps

ISFL250/400/630/1250

B-32
www.se.com Functions and characteristics

Auxiliary contacts and indications


FuPacT ISFL1250

Position of auxiliary contacts for ISFL devices


ISFL1250

PB107277_25_r.eps
DB423429.eps

ISFL250/400/630/1250
B

B-33
Functions and characteristics www.se.com

Intelligent measurement
FuPacT ISFL160 to ISFL630

The future belongs to more intelligent switchboards. The new ISFL generation,
vertical design, are well prepared for the future: they offer standardized interfaces for
all types of measurement devices.
Schneider Electric is offering a complete and large offer of metering devices:
Powerlogic range.
PB104891_r.eps

PowerLogic series meter - Power Meter


PB104892_r.eps

The Power Meter serie offers many high-performance capabilities needed to meter
and monitor an electrical installation in a compact unit.
B All models include an easy-to-read display that presents measurements for all three
phases and neutral at the same time, total harmonic distortion (THD) metering, and
alarming.
Some models offer an incremental choice of custom logging and power quality
analysis capabilities.
Expand any model with field-installable option modules that offer a choice of
DB404267.eps

additional digital inputs and outputs, analog inputs and outputs, and ethernet port.

Flexible measurement options - the amperemeter


Empty plastic box for ISFL160 Additional measurement options are possible using an amperemeter which is
adjusted onto the new amperemeter-bracket. The installation is incredibly simple
and the returns extremely versatile.
DB404268.eps

How to install device


bb For ISFL160, you can use an empty box to include measurement device:
vv plastic box
Empty plastic box for ISFL250/400/630 vv dimension 46 x 46 mm for the cut-out
vv length: the same as the length adaptor to be able to put the ISFL160 beside
ISFL250 to ISFL630
vv fixation by mounting it directly to the top of the product.
bb For ISFL250 to 630, you can use empty boxes to include measurement devices:
vv plastic box
DB404269.eps

vv dimension 72 x 72 mm and 96 x 96 mm for the cut-out


vv fixation by mounting it directly to the top of the product.

ISFL250-630 + Empty box with power meter

B-34
www.se.com
Installation recommendations
Possible installation positions and mounting
FuPacT ISFL160 to ISFL1250

Possible installation positions


ISFL160 to 1250 ISFL160 to 630
DB423442.eps

DB423443.eps

Possible mounting B
ISFT100N
ISFp160 to ISFp630
ISFL1250
DB423446.eps

Securely tightened

B-35
Installation recommendations www.se.com

Implementation and power dissipation


FuPacT ISFL

Reverse supply
FuPacT fusegear may be supplied equally well via the upstream or downstream
terminals, without any reduction in performance.

Conductor materials and electrodynamic forces


FuPacT fusegear may be connected using either bare copper, tinned copper or
tinned aluminium conductors (flexible or rigid bars, cables).
In the event of a short-circuit, thermal and electrodynamic forces are exerted on the
conductors. The conductors must therefore be adequately sized and suitably
supported.
Note that the terminals of electrical devices (switch-disconnectors, contactors, circuit
breakers, etc.) should not be considered to contribute to the support of the
conductors.
B Cable ties and flexible bars
The table below indicates the maximum distances between cable ties depending on
the prospective short-circuit current.
Do not to exceed a distance of 400 mm between ties strongly fixed to the
switchboard frame.
Type of tie “Panduit” type “Sarel” type
Width: 4.5 mm Width: 9 mm
Max. load: 22 kg Max. load: 90 kg
Color: white Color: black
Max. distance 200 100 50 350 200 100 70 50 (double
between ties (mm) ties)
Short-circuit current 10 15 20 20 27 35 45 100
(kA rms)
Note: for cables u 50 mm2, 9 mm wide ties must be used.

Tightening torque for ISFL with screw connection


Type Torque
(Nm)
ISFL ISFL160 1-pole version with direct connection to 185 mm busbars 14
ISFL160 1-pole version with hook-on connection to 185 mm busbars 14
ISFL160 3-pole version with direct connection to 100 mm busbars 14
ISFL160 3-pole version with hook-on connection to 60 mm busbars 6
ISFL160 3-pole version with direct connection to 185 mm busbars with kit 14
ISFL160 3-pole version with connectors for flexible bars 4
ISFL160 3-pole version with conectors for bare Cu/Al cables 4
ISFL 250 1-pole and 3-pole version with direct connection to 185 mm busbars 32
ISFL 400 1-pole and 3-pole version with direct connection to 185 mm busbars 32
ISFL 630 1-pole and 3-pole version with direct connection to 185 mm busbars 32
ISFL 1250 3-pole version with direct connection to 185 mm busbars 32

B-36
www.se.com
Installation recommendations
Implementation and power dissipation
FuPacT ISFL

Power dissipated by ISFL fuse-switch disconnectors


Power dissipated per pole
Switchgear Fuse-link Total
Rating Model Resistance Power Max. power Total power
per pole dissipated dissipated dissipated per
per pole pole
(A) (mW) (W) Rat. (A) P (W) (W)
Device bolted directly to busbars 160 ISFL160 1-pole 0.268 6.7 160 12 19
(without conversion kit) 3-pole
250 ISFL250 1-pole 0.144 9.0 250 32 32
3-pole
400 ISFL400 1-pole 0.117 18.7 400 45 53
3-pole
630 ISFL630 1-pole 0.093 37 630 48 85

1250
3-pole
ISFL1250 3-pole 0.093 37 630 48 85
B
With conversion kit 160 ISFL160 0.230 5.9 160 12 18

B-37
Dimensions and connection www.se.com

FuPacT ISFL160 3 x 1P
Dimensions and mounting

Dimensions
Fuse-carrier closed Front Open and locked

200
123 172
97 150
DB423314.eps

DB423315.eps

DB423316.eps
100

285

B
X X
672 X
745

380

50

Z Y
Z
Mounting
For 185 mm busbars
DB423317.eps

185

185

3 Ø8.5

B-38
www.se.com
Dimensions and connection
FuPacT ISFL160 3 x 1P
Dimensions and mounting

For 1 device with side cover and/or 1 free slot


51

[a]
[a]
DB430662.eps

DB423319.eps

DB423320.eps
173
285

X 185

92.5
642
X X
B
745

173

[b]

[b]

90 74
Y
123
Y
Z

[a] Side cover for front panel cut-out.


[b] Terminal shields.

B-39
Dimensions and connection www.se.com

FuPacT ISFL160 1 x 3P
Dimensions and mounting

Dimensions
Fuse-carrier closed Front Open and locked
223
60 mm 100 mm 179

DB423324.eps
123 158
22 70 102
DB423322.eps
DB423321.eps

DB423323.eps

X X X X
360
405

B 216
150

251

26

102 50
Z Z Y Z

With 185 mm connection kit With 185 mm connection kit for 2 ISFL devices
34 102
DB423325.eps

DB423326.eps

212

X X
464.5

44 50
100

Z Y

Mounting
With connection kit for 185 mm
For 60 mm busbars For 100 mm busbars busbars
DB423329.eps
DB423328.eps
DB423327.eps

185
9 x 15 100
7 60
X X X X
60
Ø9
100

185

9 x 15 3 Ø8.5

3 Ø12.5

Y Y Y Y
B-40
www.se.com
Dimensions and connection
FuPacT ISFL160 1 x 3P
Dimensions and mounting

For 1 device with side cover and/or 1 free slot


50

DB423331.eps
[a] [a]

DB423332.eps
DB423330.eps

150 160

X X X
205
361
425

[b]
B
[b]

L 18 25
123 71.5
Z Y Y
[a] Side cover for front panel cut-out.
[b] Terminal shields.

With length adapter


DB423334.eps

DB423335.eps
DB423333.eps

X X X

671

Y Y

95 50 50

B-41
Dimensions and connection www.se.com

FuPacT ISFL160 1 x 3P
Connection and accessories

Connection
Connection via lugs/flexible bars Connection via connectors
X X X X
DB423336.eps

DB423337.eps

DB423338.eps

DB423339.eps
175 175

L3

30 30
L2
2 M5
30 30
L1 8

B
3 10 24 7 7
21 20 1 M8 48
45 10
20 Z Y
Z Y Y

X X

175
DB423341.eps
DB423340.eps

L3

30
L2
30 2 M5
L1
8

3 1 M8
21 10
45 20
10 Y
Z 20

Current transformer
Direct connection to 100 mm busbars
50 123
20 25
DB423342.eps

53
97

328.5
100

X X X

100

Z Y Z

B-42
www.se.com
Dimensions and connection
FuPacT ISFL250 to 630 1 x 3P
Dimensions and mounting

Dimensions
Fuse-carrier closed Front Open and locked
364
256

DB423345.eps
190 196.5
150 150
DB423343.eps

DB423344.eps

286

B
X X X

741

278

455 456

135 100

Z Y Z

Mounting
For 185 mm busbars
DB423346.eps

185
Ø14.5

185

B-43
Dimensions and connection www.se.com

FuPacT ISFL250 to 630


Dimensions and mounting

Device with side cover


100

[a]

DB423348.eps
[a]
DB423347.eps

DB423349.eps
303

435
X X X
B 850
250 645
211.5

[b]
[b]

150 18 50
123 [a] S
 ide cover for front
190 panel cut-out.
[b] Terminal shields.
Z Y Y

With measurement device


150
135 135
68.5
DB423350.eps

DB423351.eps

DB423352.eps

X X X
795

Z Y Y

B-44
www.se.com
Dimensions and connection
FuPacT ISFL1250
Dimensions and mounting

Dimensions
Fuse-carrier closed Front Open and locked
190 364
150 256
DB423353.eps

DB423354.eps

DB423355.eps
196.5
150

286

X
B
X

278
834

549

549

135 200
161.6
Y Z
Z

Mounting
For 185 mm busbars
DB423356.eps

185
Ø14.5

185

B-45
Dimensions and connection www.se.com

FuPacT ISFL1250
Dimensions and mounting

Device with side cover


200

DB423358.eps
[a] (a)
DB423357.eps

DB423359.eps
303

435
X X X
B 850
250 645
211.5

[b] (b)
223

Y
18 100

150 Y
190 [a] S
 ide cover for front
panel cut-out.
Z [b] Terminal shields.

B-46
www.se.com
Dimensions and connection
FuPacT ISFL1250
Connection and accessories

Connection
Connection via lugs/flexible bars Connection via connectors
X X X X
DB423360.eps

DB423361.eps

DB423362.eps

DB423363.eps
290 290
340 340

B
17 24 64.7 24
20
44.2 48 118.7 48
74
98.2
Z Y Z Y

Current transformer
DB423365.eps
DB423364.eps

X X
63

20 60
30
Y
Z

B-47
Wiring diagrams www.se.com

FuPacT ISFL

Power

DB423475.eps
FU01 FU02 FU03

Auxiliary contacts
B ISFL160 ISFL250 to 630
DB423476.eps

DB423477.eps
ISFL1250
DB423478.eps

Blown fuse
ISFL160 to 1250 fuse monitor
DB423479.eps

22
21
14
13

B-48
www.schneider-electric.com

FuPacT GS

Presentation
Offer panorama.........................................................................C-2
FuPacT GS 32 A............................................................................... C-2
FuPacT GS 50/63 A.......................................................................... C-3
FuPacT GS 100-160 A..................................................................... C-4
FuPacT GS 200/400 A..................................................................... C-5
FuPacT GS 630/800 A..................................................................... C-6
FuPacT GS 1250 A........................................................................... C-7

Characteristics
IEC switch-disconnector-fuses
for use with NFC or DIN fuses.............................................C-8
IEC switch-disconnector-fuses
for use with BS fuses........................................................... C-12
Detailled presentation
C
Presentation of the FuPacT GS range.......................... C-16
FuPacT GSB and GSC 32............................................................. C-16
FuPacT GSC 50, GSB and GSD 63.............................................. C-18
FuPacT GSB 100, GSC and GSD 125, GSB and GSD 160......... C-20
FuPacT GSB 200, GSB and GSD 250, GSB and GSD 400.......... C-22
FuPacT GSB and GSD 630, GSB and GSD 800.......................... C-24
FuPacT GSB and GSD 1250......................................................... C-26
FuPacT GSB and GSD 1250......................................................... C-27

Dimensions and connection


FuPacT GS 32 A.................................................................... C-28
Dimensions..................................................................................... C-28
Mounting and front panel cut-outs................................................. C-29
FuPacT GS 50/63 A.............................................................. C-30
Dimensions..................................................................................... C-30
Mounting and front panel cut-outs................................................. C-31
FuPacT GS 100/160 A......................................................... C-32
Dimensions..................................................................................... C-32
Mounting and front panel cut-outs................................................. C-33
FuPacT GS 200/400 A......................................................... C-34
Dimensions..................................................................................... C-34
Mounting and front panel cut-outs................................................. C-35
FuPacT GS 630/800 A......................................................... C-36
Dimensions..................................................................................... C-36
Mounting and front panel cut-outs................................................. C-37
FuPacT GS 1250 A............................................................... C-38
Dimensions..................................................................................... C-38
Mounting and front panel cut-outs................................................. C-39
FuPacT GS 32 to 1250 A.................................................... C-40
Class II installation.......................................................................... C-40

Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT ISFL............................................................................................... B-1
Catalog numbers........................................................................................D-1

C-1
Presentation www.se.com

Offer panorama
FuPacT GS 32 A
DB436384.ai

A1 B

N
O

O
OFF
N
O

O
OFF
N
O
A2
O
OFF

C
ON

G
OFF

I
ON
OFF

F E D ON
I
OFF

ON

OFF

I
ON
OFF

A Switch disconnector fuse 3P or 4P D Extended front handles


(neutral switched, not protected)
E Shaft
1- GSB 32 A
2- GSC 32 A F Direct handle
B Extended lateral handles G NO or NC auxiliary contacts
C Guide cone

C-2
www.se.com
Presentation
Offer panorama
FuPacT GS 50/63 A
DB436385.ai

A1 B C D

N
O

O
OFF
N
O

O
OFF
E

N
O
A2

C
O
OFF

A3

H ON
I G ON
I
OFF

OFF

I
ON
OFF

A Switch disconnector fuse 3P or 4P C NO or NC auxiliary contacts G Extended front handles


1- GSB 63 A
D Extended lateral handles H Shaft
2- GSC 50 A
3- GSD 63 A E Direct handle
B External neutral module F Guide cone

C-3
Presentation www.se.com

Offer panorama
FuPacT GS 100-160 A
DB436386.ai

B D E F

N
O

O
OFF
N
O
C

O
OFF
A

N
O

O
OFF
C

I H
I I
ON ON
OFF
OFF

O
O

I
ON
OFF

A Switch disconnector fuse 3P or 4P C Bare cable connector G Guide cone


b GSB 100/160 A
D NO or NC auxiliary contacts H Extended front handles
b GSC 125 A
b GSD 125/160 A E Extended lateral handles I Shaft
B Terminal shield F Direct handle J External neutral module

C-4
www.se.com
Presentation
Offer panorama
FuPacT GS 200/400 A
DB436387.ai

B D E F

N
O

O
OFF
N
O
C

O
OFF
A

N
O

O
OFF
C

I
ON

I H
I
ON
OFF

O
OFF

I
ON
OFF

A Switch disconnector fuse 3P or 4P D NO or NC auxiliary contacts H Extended front handles


b GSB 200/250/400 A
E Extended lateral handles I Shaft
b GSD 250/400 A
B Terminal shield F Direct handle J External neutral module

C Bare cable connector G Guide cone

C-5
Presentation www.se.com

Offer panorama
FuPacT GS 630/800 A
DB436388.ai

B C D

N
O

O
OFF
N
O

O
OFF
A

N
O

O
OFF
C
E

I
ON
OFF

H G F

I
ON
OFF

I
ON
OFF

A Switch disconnector fuse 3P or 4P C NO or NC auxiliary contacts F Extended front handles


b GSB 630/800 A
D Extended lateral handles G Shaft
b GSD 630/800 A
B Terminal shield E Guide cone H External neutral module

C-6
www.se.com
Presentation
Offer panorama
FuPacT GS 1250 A
DB436389.ai

B C D

N
O

O
OFF
N
O

O
OFF
A

N
O

O
OFF
E C

O
OFF
ON

H G F
OFF
O
ON

OFF
O
ON

A Switch disconnector fuse 3P or 4P C NO or NC auxiliary contacts F Extended front handles


b GSB 1250 A
D Extended lateral handles G Shaft
b GSD 1250 A
B Terminal shield E Guide cone H External neutral module

C-7
Characteristics www.se.com

IEC switch-disconnector-fuses
for use with NFC or DIN fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSC32 GSC50 GSD63

Environment
Conforming to standards Switch-disconnector-fuses IEC 60947-3
Fuses IEC60269/NFC63320 & IEC60269/BS88
Product certifications IEC and CCC
Degree of protection On Front panel, with terminal covers IP 20
conforming to IEC 60529
Ambient air temperature Storage °C -50 …+85
around the device Operation °C -20…+70
Flame resistance Body °C 960
conforming to Fuse cover °C – 850
IEC 60695-2-1
Pole characteristics following IEC 60947-1 / IEC 60947-3 et EN 60947-1 / EN 60947-3
Number of poles / Number 3 poles / 3 fuses b b b
of fuses 3 poles / Neutral switched NOT Protected b – –
4 poles / 4 fuses – b b
Type of fuses Fuse size 10x38 14x51 NH 000

C Conventional thermal
current
At ambient temperature (Ith) at 35°C A 32 50 63
Maximum admissible power W 2.9 4.6 6.0
dissipated by the fuse
Maximum power dissipated by a pole W 1.2 4.6 4.4
Derating in the open air or in at 40°C A 30 48 60
cubicle at 50°C A 27 43 54
at 60°C A 24 37 47
at 70°C A 20 31 39
Rated insulation voltage (Ui) 50/60 Hz V 800 800 800
Rated impulse withstand voltage (Uimp) kV 8 8 8
Rated operating voltage - AC (Ue) 50/60 Hz V 690 690 690
Rated operating voltage - AC 20 (Ue) V 800 800 800
Rated operational current Cat. AC-22A/B [1] 220/240 V A 32 50 63
at 50/60 Hz 380/415 V A 32 50 63
660/690 V A 32 50 63
Rated operational current Cat. AC-23A/B [1] 220/240 V A 32 50 63
at 50/60 Hz 380/415 V A 32 50 63
660/690 V A 32 50 63
Rated operational power Cat. AC-23A/B [1] 380/415 V kW 15 25 30
660/690 V kW 25 45 55
Breaking capacity with fuses (Iq) 400 V kA rms – – –
415 V kA rms 100 100 100
500 V kA rms – – –
690 V kA rms 100 100 100
Mechanical durability in cycle 0/C 10000 10000 10000
Durability in cycle 0/F Category Category A
Mechanical in cycle 0/C 8500 8500 8500
Electrical AC22A 415 V 1500 1500 1500
AC22A 690 V 1500 1500 1500
AC23A 415 V 1500 1500 1500
AC23A 690 V 1500 1500 1500
Sectioning ability Yes Yes Yes
Fully apparent cut No No No
Degree of pollution III III III
[1] Category "A": frequent operating cycles, category "B": infrequent operating cycles.

C-8
www.se.com
Characteristics

GSC125 GSD125 GSD160 GSD250 GSD400 GSD630 GSD800 GSD1250

IEC 60947-3
IEC60269/NFC63320 & IEC60269/BS88
IEC and CCC
IP 20

-50 …+85
-20…+70
960
850

b b b b b b b b
– – – – – – – –
b b b b b b b b
22x58 NH 00 NH 00 NH 1 NH 2 NH 3 NH 3 NH 4

125 125 160 250 400 630 800 1250 C


10.4 12.0 12.0 23.0 33.0 60.0 65.0 110.0

8.6 8.6 10.4 19 24.4 61 68 154


119 119 152 238 382 600 762 1195
107 107 136 213 345 537 682 1079
93 93 119 186 305 469 595 955
78 78 100 156 262 393 499 819
800 800 800 800 800 1000 1000 1000
8 8 8 8 8 12 12 12
690 690 690 690 690 690 690 690
800 800 800 800 800 1000 1000 1000
125 125 160 250 400 630 800 1250
125 125 160 250 400 630 800 1250
125 125 160 250 400 630 800 –
125 125 160 250 400 630 800 1250
125 125 160 250 400 630 800 1250
100 125 – 250 315 – – –
70 70 80 132 220 355 450 750
110 110 110 220 295 295 600 900
– – – – – – – –
50 50 50 50 100 100 100 100
– – – – – – – –
100 50 50 – – – – –
10000 10000 10000 10000 8000 5000 5000 5000
Category A Category B
7000 7000 7000 7000 800 800 500 500
1000 1000 1000 1000 200 200 100 100
1000 1000 1000 1000 200 200 100 100
1000 1000 1000 1000 – – – 100
1000 1000 1000 1000 – – – –
Yes Yes Yes Yes Yes Yes Yes Yes
No No No No No No No No
III III III III III III III III

C-9
Characteristics www.se.com

IEC switch-disconnector-fuses
for use with NFC or DIN fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSC32 GSC50 GSD63

Installation and connection


Upstream / Downstream connection b b b
Rear connection – – –
Connexion material and surface treatment White zinc plated steel Tinned copper

Control auxiliaries
Directe front rotary handle b b b
Front extended handle b b b
Laterale extend handle b b b
Padlocking b b b
Signaling auxiliaries
Auxiliary contact with pre-cut information b b b
Test position b b b
Installation and connection accessories
Internal neutral link – b b

C External neutral module


Terminal covers


b

b

Cable connector – – –
Dimensions and weights
Overall dimensions W x H x D 3P mm 96 x 98 x 65 121 x 118 x 87 136 x 162 x 116
4P mm 96 x 98 x 65 148 x 118 x 87 168 x 162 x 116
Approximate weigth without fuses and 3P kg 0.5 0.8 1.0
accessories 4P kg 0.5 1.0 1.3
Operating torque (typical for a 3-pole) Nm 8.7 8.7 8.7

GS1 AM110 and GS1 AM101 early break and signaling contact characteristics
Conventional thermal current (Ith) for ambient temperature y 40 °C A 10

Rated operational current (Ie) Cat. AC-15 A 120 V: 6 - 240 V: 3 - 400 V: 1.8 - 480 V: 1.5

Cat. DC-13 A 24 V: 2.8 - 48 V: 1.4 - 125 V: 0.55 - 250 V: 0.27 - 400 V: 0.15

Durability Number of operating cycles Mechanical: 5000000


Electrical: cat. AC-15: 1000000
Cabling Cable (c.s.a. min/max) mm2 Min: 1 x 0.22 - max: 2 x 2.5

C-10
www.se.com
Characteristics

GSC125 GSD125 GSD160 GSD250 GSD400 GSD630 GSD800 GSD1250

b b b b b b b b
– – – – – b b b
Tinned copper

b b b b b – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b

b b b b b b b b
b b b b b – – –

b b b b b b b b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
C
b b b b b – – –

148 x 162 x 116 148 x 162 x 116 148 x 162 x 116 234 x 195 x 146 252 x 205 x 149 364 x 300 x 250 364 x 300 x 250 442 x 300 x 289
184 x 162 x 116 184 x 162 x 116 184 x 162 x 116 294 x 195 x 146 318 x 205 x 149 458 x 300 x 250 458 x 300 x 250 562 x 300 x 289
1.5 1.5 1.8 3.2 4.8 16.0 17.0 25.0
2.0 2.0 2.3 4.5 6.1 20.0 21.5 30.0
8.7 8.7 9.7 13 17 56 56.7 62

C-11
Characteristics www.se.com

IEC switch-disconnector-fuses
for use with BS fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSB32 GSB63 GSB100

Environment
Conforming to standards Switch-disconnector-fuses IEC 60947-3
Fuses IEC60269/NFC63320 & IEC60269/BS88
Product certifications IEC and CCC
Degree of protection On Front panel, with terminal covers IP 20
conforming to IEC 60529
Ambient air temperature Storage °C -50 …+85
around the device Operation °C -20…+70
Flame resistance Body °C 960
conforming to Fuse cover °C – 850
IEC 60695-2-1
Pole characteristics following IEC 60947-1 / IEC 60947-3 et EN 60947-1 / EN 60947-3
Number of poles / Number 3 poles / 3 fuses b b b
of fuses 3 poles / Neutral switched NOT Protected b – –
4 poles / 4 fuses – b b
Type of fuses Fuse size A1 A2–A3 A4

C Conventional thermal
current
At ambient temperature (Ith) at 35°C A 32 63 100
Maximum admissible power W 2.9 3.8 8.4
dissipated by the fuse
Maximum power dissipated by a pole W 1.2 4.4 3.7
Derating in the open air or in at 40°C A 30 60 95
cubicle at 50°C A 27 54 85
at 60°C A 24 47 74
at 70°C A 20 39 62
Rated insulation voltage (Ui) 50/60 Hz V 800 800 800
Rated impulse withstand voltage (Uimp) kV 8 8 8
Rated operating voltage - AC (Ue) 50/60 Hz V 690 690 690
Rated operating voltage - AC 20 (Ue) V 800 800 800
Rated operational current Cat. AC-22A/B [1] 220/240 V A 32 63 100
at 50/60 Hz 380/415 V A 32 63 100
660/690 V A 32 63 100
Rated operational current Cat. AC-23A/B [1] 220/240 V A 32 63 100
at 50/60 Hz 380/415 V A 32 63 100
660/690 V A 32 63 100
Rated operational power Cat. AC-23A/B [1] 380/415 V kW 15 30 51
660/690 V kW – 55 90
Breaking capacity with fuses (Iq) 400 V kA rms – – –
415 V kA rms 100 100 50
500 V kA rms – – –
690 V kA rms 80 100 50
Mechanical durability in cycle 0/C 10000 10000 10000
Durability in cycle 0/F Category Category A
Mechanical in cycle 0/C 8500 8500 8500
Electrical AC22A 415 V 1500 1500 1500
AC22A 690 V 1500 1500 1500
AC23A 415 V 1500 1500 1500
AC23A 690 V 1500 1500 1500
Sectioning ability Yes Yes Yes
Fully apparent cut No No No
Degree of pollution III III III
[1] Category "A": frequent operating cycles, category "B": infrequent operating cycles.

C-12
www.se.com
Characteristics

GSB160 GSB200 GSB250 GSB400 GSB630 GSB800 GSB1250

IEC 60947-3
IEC60269/NFC63320 & IEC60269/BS88
IEC and CCC
IP 20

-50 …+85
-20…+70
960
850

b b b b b b b
– – – – – – –
b b b b b b b
A4 B1–B2 B1…B3 B1…B4 C2 C3 D1

160 200 250 400 630 800 1250 C


15.3 14.3 19.7 29.6 55 70 100

10.4 8.8 13.8 24.4 61 68 154


152 190 238 382 600 762 1195
136 170 213 345 537 682 1079
119 149 186 305 469 595 955
100 125 156 262 393 499 819
800 800 800 800 1000 1000 1000
8 8 8 8 12 12 12
690 690 690 690 690 690 690
800 800 800 800 1000 1000 1000
160 200 250 400 630 800 1250
160 200 250 400 630 800 1250
160 200 250 400 630 800 1250
160 200 250 400 630 800 1250
160 200 250 400 630 800 1250
– 160 250 315 – – –
80 100 132 220 355 450 750
110 150 220 295 295 400 900
– – – – – – –
50 50 100 50 100 100 100
– – – – – – –
50 – – – 80 80 80
10000 10000 10000 8000 5000 5000 5000
Category A Category B
7000 7000 7000 800 800 500 500
1000 1000 1000 200 200 100 100
1000 1000 1000 200 200 100 100
1000 1000 1000 – – – 100
1000 1000 1000 – – – –
Yes Yes Yes Yes Yes Yes Yes
No No No No No No No
III III III III III III III

C-13
Characteristics www.se.com

IEC switch-disconnector-fuses
for use with BS fuses
From 32 to 1250 A
Switch-disconnector-fuse characteristics
Type GSB32 GSB63 GSB100

Installation and connection


Upstream / Downstream connection b b b
Rear connection – – –
Connexion material and surface treatment White zinc plated Tinned copper
steel
Control auxiliaries
Directe front rotary handle b b b
Front extended handle b b b
Laterale extend handle b b b
Padlocking b b b
Signaling auxiliaries
Auxiliary contact with pre-cut information b b b
Test position b b b
Installation and connection accessories
Internal neutral link – – –

C External neutral module


Terminal covers


b

b
b
Cable connector – – b
Dimensions and weights
Overall dimensions W x H x D 3P mm 96 x 98 x 83 136 x 162 x 116 148 x 162 x 116
4P mm 96 x 98 x 83 168 x 162 x 116 184 x 162 x 116
Approximate weigth without fuses and 3P kg 0.5 1.0 1.5
accessories 4P kg 0.5 1.3 2.0
Operating torque (typical for a 3-pole) Nm 8.7 8.7 9.7

GS1 AM110 and GS1 AM101 early break and signaling contact characteristics
Conventional thermal current (Ith) for ambient temperature y 40 °C A 10

Rated operational current (Ie) Cat. AC-15 A 120 V: 6 - 240 V: 3 - 400 V: 1.8 - 480 V: 1.5

Cat. DC-13 A 24 V: 2.8 - 48 V: 1.4 - 125 V: 0.55 - 250 V: 0.27 - 400 V: 0.15

Durability Number of operating cycles Mechanical: 5000000


Electrical: cat. AC-15: 1000000
Cabling Cable (c.s.a. min/max) mm2 Min: 1 x 0.22 - max: 2 x 2.5

C-14
www.se.com
Characteristics

GSB160 GSB200 GSB250 GSB400 GSB630 GSB800 GSB1250

b b b b b b b
– – – – b b b
Tinned copper

b b b b – – –
b b b b b b b
b b b b b b b
b b b b b b b

b b b b b b b
b b b b – – –

– – – – – – –
b
b
b
b
b
b
b
b
b
b
b
b
b
b C
b b b b – – –

190 x 162 x 136 234 x 195 x 146 234 x 195 x 146 252 x 205 x 149 364 x 300 x 250 364 x 300 x 250 442 x 300 x 289
240 x 162 x 136 294 x 195 x 146 294 x 195 x 146 318 x 205 x 149 458 x 300 x 250 458 x 300 x 250 562 x 300 x 289
2.3 3.2 3.2 4.8 16.0 17.0 25.0
2.3 4.5 4.5 6.1 20.0 21.5 30.0
9.7 13 13 17 56 56.7 62

C-15
Detailled presentation www.se.com

Presentation of the FuPacT GS range


FuPacT GSB and GSC 32

Functions
The FuPacT GSB32 and GSC32 switch disconnector fuses are used with fuses that
protect electrical circuits against overloading and short circuits.
DB436418.ai
DB436417.ai

They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.

Format and installation


The FuPacT GSC32 and GSB32 devices are compact and monobloc (96 mm wide),
FuPacT GSC32 FuPacT GSB32
thereby optimizing the space used.
The dimensions of the 3- and 4-pole devices are identical.
The devices are installed either on a DIN rail or by means of mounting screws on a
plate. The mounting points are incorporated into the products. There is no need to
add accessories to fasten the products to a plate.

C Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
DB436419.ai

DB436420.ai

The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
The 4P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse and a neutral connection, cut-off, UNPROTECTED.
3 poles, 3 fuse-links 4 poles, 3 fuse-links
Controlling the devices
bb The devices can be controlled in three ways:
vv By direct control using reference GS1AH103. This control is fitted directly
DB436422.ai
DB436421.ai

to the device.
vv By extended frontal control with a handle installed on the door of the electrical
ON

OFF

cabinet.
vv By extended lateral control with a handle installed on the side of the electrical
cabinet.
Direct handle Extended front handles bb The control rods are available in 3 lengths: 200 , 320 or 400 m.
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered separately
vv For frontal installation, black or yellow/red with or without test position
DB436423.ai

vv For lateral installation, black or yellow/red without test position


bb The front handles allow the door to be interlocked with the control rod of the
device. This prevents the opening of the door cabinet if the device is in the ON
position.
Extended lateral handles
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
DB436425.ai

The function whereby the devices can be locked in the OFF position is available on
DB436424.ai

ON

OFF
the direct control handle and the extended control handles.
It allows up to 3 padlocks to be fitted on each handle.

Using the devices as emergency switch disconnector fuse


3 padlocks 3 padlocks The FuPacT switch disconnector fuse can be used as emergency cut-off devices.
on direct handle on extended handle For this application, they must be easily visible, accessible and identifiable (see
standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
For the purposes of easy identification, the emergency cut-off switch disconnectors
fuse use special colors, as stipulated by the standards and different from those of the
DB436426.ai

standard version:
DB436427.ai

bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
disconnector fuse are the same as those of the standard version.
Extended front handles, Extended lateral handles,
red handle on yellow front red handle on yellow front

C-16
www.se.com Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB and GSC 32

Connecting the devices


The FuPacT GSC32 and GSB32 devices are fitted with screw terminals which can
accommodate conductors of 2.5 to 16 mm² cross section.

DB436428.ai
Fuse type and installation
bb GSC 32 supports NF 10*38 cylindrical fuses compliant with IEC60269/NFC63320

DB436429.ai
standards.
C

DB425715.eps
bb GSB 32 supports BS A1 fuses compliant with IEC60269/BS88 standards.
Note: The fuses are not supplied with the devices.

bb For GSC 32, the fuses are installed in the cover, opened prior to installation.
NFC fuse BS fuse
bb For GSB 32, the fuses are installed in the device on the mountings provided for
this purpose. Manual tightening is strongly advised in order to comply with the
recommended tightening torques (consult the instruction sheet ).

DB436527.ai

DB436528.ai
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm
DB436430.ai

Auxiliary contacts/Pre cut-off


The GSC32 and GSB32 devices can be fitted with 4 auxiliary contacts enabling the
mechanical position of the device to be indicated. 2 auxiliary contacts are fitted
directly to the device (see manual) and 2 others can be stacked on top of the first
ones.
DB436431.ai
The NO or NC auxiliary contacts thus allow the ON, OFF and TEST positions of the
device to be indicated.
The TEST position is indicated if a handle WITH TEST position is used.
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.

C-17
Detailled presentation www.se.com

Presentation of the FuPacT GS range


FuPacT GSC 50, GSB and GSD 63

DB436438.ai
DB436437.ai

Functions
The FuPacT GSC50, GSB63 and GSD63 switch disconnector fuses are used with
fuses that protect electrical circuits against overloading and short circuits.
FuPacT GSC 50 FuPacT GSD 63 They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.
DB436439.ai

Format and installation


The FuPacT GSC 50, GSD 63 and GSB 63 devices are compact, optimizing the
space used. They consist of poles assembled and tested in factory as well as a
housing for the control mechanism.
FuPacT GSB 63 The transparent covers make it possible to see the presence or absence of fuses
and their rating.
The devices are installed either on a DIN rail or by means of mounting screws on a
plate. The mounting points are incorporated into the products. There is no need to
DB436419.ai

DB436440.ai

add accessories to fasten the products to a plate.

C Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
3 poles, 3 fuse-links 4 poles, 4 fuse-links
the fuse.
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral link (see internal neutral links).
DB436441.ai

Controlling the devices


bb The devices can be controlled in three ways:
vv By direct control using reference LV481701. This control is fitted directly to the
housing of the device control mechanism.
vv By extended frontal control with a handle installed on the door of the electrical
Direct handle
cabinet.
vv By extended lateral control with a handle installed on the side of the electrical
cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
DB436443.ai
DB436442.ai

Note: They must be ordered separately.


bb Several types of IP65 control handle are available and must be ordered
separately.
vv In the event of frontal installation, black or yellow/red, with or without test
Extended front handles Extended lateral handles position.
vv For lateral installation, black or yellow/red, without test position.
bb The front handles allow the door to be interlocked with the control rod of the
DB436444.ai

device. This prevents the opening of the door cabinet if the device is in the ON
DB436447.ai

position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
The function whereby the devices can be locked in the OFF position is available on
3 padlocks 3 padlocks the direct control handle and the extended control handles.
on direct handle on extended handle It allows up to 3 padlocks to be fitted on each handle.
It is also possible to padlock the devices directly, either on the control unit using a
single padlock or a multi-padlock lockout accessory or on the lockout tab located on
the lower face of the control unit. This can accommodate up to 3 padlocks.
DB436445.ai

DB436446.ai

Using the devices as emergency switch disconnector fuse


The FuPacT switch disconnector fuse can be used as emergency cut-off devices.
For this application, they must be easily visible, accessible and identifiable (see
standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
single padlock 3 padlocks
directly on device on lockout tab For the purposes of easy identification, the emergency cut-off switch disconnector
fuse use special colors, as stipulated by the standards and different from those of the
standard version:
N
O

bb yellow for the front face of the device or the control plate
DB436448.ai

DB436449.ai

bb red for the handle.


O
OFF

ON
I
The performance characteristics of the FuPacT emergency cut-off switch
disconnector fuse are the same as those of the standard version.
OFF

Extended front handles, Extended lateral handles,


red handle on yellow front red handle on yellow front
C-18
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSC 50, GSB and GSD 63

DB436450.ai
Connecting the devices
The FuPacT GSC 50, GSD 63 and GSB 63 devices are fitted with screw terminals
which can accommodate conductors of:
bb 10 to 25 mm² for the GSC 50
bb 16 to 25 mm² for the GSD 63 and GSB 63.

Fuse type and installation

DB436429.ai

DB436497.ai
bb GSC 50 supports NF 14*51 cylindrical fuses compliant with IEC60269/NFC63320

DB425715.eps
standards
bb GSD 63 supports DIN 000 fuses compliant with IEC60269/NFC63320 standards
bb GSB 63 supports BS A2 and A3 fuses compliant with IEC60269/BS88 standards
Note: The fuses are not supplied with the devices.
NFC fuse BS fuse DIN fuse C
bb For GSC 50 and GSD 63, the fuses are installed by rotating the transparent
protective cover, with the power supply switched off, then inserting the fuses in the
fuse holders.

DB436452.ai

DB436453.ai
bb For GSB 63, the fuses are installed by removing the transparent protective cover,
with the power supply switched off, then installing the fuses on the mounitng
provided for this purpose. Manual tightening is strongly advised in order to comply
with the recommended tightening torques (consult the device manual).

External neutral module and internal neutral link


The NFC 50A and DIN 63A (LV481911 and LV481913) neutral links create a neutral
connection in the device. The links are fitted instead of a fuse.
The external neutral modules are poles fitted with a removable neutral connection
which is NOT CUT (no mechanism).
They are installed directly on the left-hand side of the product on the 3-pole device.
DB436454.ai

DB436456.ai
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled DIN link
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.

Auxiliary contacts / Pre cut-off


The FuPacT GSC 50, GSB 63 and GSD 63 devices can be fitted with 4 auxiliary
contacts enabling the mechanical position of the device to be indicated.
2 auxiliary contacts are fitted directly to the device (see manual) and 2 others can be
DB436430.ai

stacked on top of the first ones.


The NO or NC auxiliary contacts thus allow the ON, OFF and TEST positions of the
device to be indicated
The TEST position is indicated if a handle WITH TEST position is used
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
DB436457.ai

This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone
Reference LV481110 is a packet of 10 plastic tappets

C-19
Detailled presentation www.se.com

Presentation of the FuPacT GS range


FuPacT GSB 100, GSC and GSD 125, GSB and GSD 160

Functions
DB436458.ai

The FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160 switch disconnector
fuses are used with fuses that protect electrical circuits against overloading and
short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.

Format and installation


The FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160 devices are compact,
FuPacT GSB 100 optimizing the space used.
They consist of poles assembled and tested in factory as well as a housing for the
control mechanism.
The transparent covers make it possible to see the presence or absence of fuses
and their rating.
DB436419.ai

DB436440.ai

The devices are installed on a plate. The mounting points are incorporated into the

C products. There is no need to add accessories to fasten the products to a plate.

Number of poles
3 poles, 3 fuse-links 4 poles, 4 fuse-links The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
<Sansliend'intersection>

The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral links.

Controlling the devices


bb The devices can be controlled in three ways:
vv By direct control using reference LV481701. This control is fitted directly to the
Direct handle housing of the device control mechanism.
vv By extended frontal control with a handle installed on the door of the electrical
cabinet.
vv By extended lateral control with a handle installed on the side of the electrical
DB436461.ai
DB436460.ai

cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered
Extended front handles Extended lateral handles separately.
vv In the event of frontal installation, black or yellow/red, with or without test
position.
vv For lateral installation, black or yellow/red, without test position.
DB436462.ai
DB436463.ai

bb The front handles allow the door to be interlocked with the control rod of the
device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.

3 padlocks 3 padlocks Lockout system


on direct handle on extended handle The function whereby the devices can be locked in the OFF position is available on
the direct control handle and the extended control handles.
It allows up to 3 padlocks to be fitted on each handle.
DB436464.ai

DB436465.ai

It is also possible to padlock the devices directly, either on the control unit using a
single padlock or a multi-padlock lockout accessory or on the lockout tab located on
the lower face of the control unit. This can accommodate up to 3 padlocks.

Using the devices as emergency switch disconnector fuse


single padlock 3 padlocks The FuPacT switch disconnector fuse can be used as emergency cut-off devices.
directly on device on lockout tab For this application, they must be easily visible, accessible and identifiable
(see standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
For the purposes of easy identification, the emergency cut-off switch disconnector
DB436466.ai

DB436467.ai

fuse use special colors, as stipulated by the standards and different from those of the
standard version:
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
Extended front handles, Extended lateral handles,
disconnector fuse are the same as those of the standard version.
red handle on yellow front red handle on yellow front
C-20
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB 100, GSC and GSD 125, GSB and GSD 160

Connecting the devices


The FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160 devices are fitted

DB436468.ai

DB436469.ai
with tin-plated terminal to connect conductors fitted with cable lugs.
Connection accessories can be used to connect directly conductors without cable lugs.
The accessories are fitted to the terminal and accommodate the bare conductors.
bb FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160: GS1AW33 (set of 3)
or GS1AW34 (set of 4).
In order to protect the direct contact connections, terminal covers may be used.
bb For FuPacT GSB 100, GSC and GSD 125: GS1AP33 (set of 3) or GS1AP34
(set of 4).
bb For FuPacT GSD and GSB 160: GS1AP43 (set of 3) or GS1AP44 (set of 4).

Fuse type and installation


bb GSB 100 support BS A4 fuses compliant with IEC60269/BS88 standards.
bb GSC 125 support NF 22*58 cylindrical fuses compliant with IEC60269/NFC63320

DB436429.ai
standards.

DB436497.ai
C

DB425715.eps
bb GSD 125 and GSD 160 support DIN 00 fuses compliant with IEC60269/
NFC63320 standards.
bb GSB 160 support BS A4 fuses compliant with IEC60269/BS88 standards.
Note: The fuses are not supplied with the devices.
NFC fuse BS fuse DIN fuse
bb For all FuPacT GSC and GSD 125, GSD 160, the fuses are installed by rotating
the transparent protective cover, with the power supply switched off, then inserting
the fuses in the fuse holders.

DB436521.ai

DB436522.ai
bb For the FuPacT GSB 100, GSB 160, the fuses are installed by rotating the
transparent protective cover, with the power supply switched off, then installing the
fuses in the housings provided for this purpose. Manual tightening is strongly
advised in order to comply with the recommended tightening torques (consult the
device manual).

External neutral module and internal neutral link


The NFC 125A and DIN 125A (LV481912 and LV481913) neutral links create a
neutral connection in the device. The links are fitted instead of a fuse.
The external neutral modules are poles fitted with a removable neutral connection
DB436470.ai
which is NOT CUT (no mechanism).
They are installed directly on the left-hand side of the product on the 3-pole device.

Cone guide
DB436456.ai
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.

Auxiliary contacts / Pre cut-off DIN link


The FuPacT GSB 100, GSC and GSD 125, GSD and GSB 160 devices can be fitted
with 4 auxiliary contacts enabling the mechanical position of the device to be
DB436430.ai

indicated.
2 auxiliary contacts are fitted directly to the device (see manual) and 2 others can be
stacked on top of the first ones.
The NO or NC auxiliary contacts thus allow the ON, OFF and TEST positions of the
device to be indicated
The TEST position is indicated if a handle WITH TEST position is used
DB436471.ai

The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.

C-21
Detailled presentation www.se.com

Presentation of the FuPacT GS range


FuPacT GSB 200, GSB and GSD 250, GSB and GSD 400

Functions
DB436472.ai

The FuPacT GSB 200, GSD and GSB 250, GSD and GSB 400 switch disconnector
fuses are used with fuses that protect electrical circuits against overloading and
short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.

Format and installation


The FuPacT GSB 200, GSD and GSB 250, GSD and GSB 400 devices are compact,
FuPacT GSB 250 optimizing the space used.
They consist of poles assembled and tested in factory as well as a housing for the
control mechanism.
The transparent covers make it possible to see the presence or absence of fuses
and their rating.
DB436419.ai

DB436440.ai

The devices are installed on a plate. The mounting points are incorporated into the
products. There is no need to add accessories to fasten the products to a plate.
C Number of poles
3 poles, 3 fuse-links 4 poles, 4 fuse-links The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
<Sansliend'intersection>

The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral links.

Controlling the devices


bb The devices can be controlled in three ways:
vv By direct control using reference LV481702. This control is fitted directly to the
housing of the device control mechanism.
Direct handle
vv By extended frontal control with a handle installed on the door of the electrical
cabinet.
vv By extended lateral control with a handle installed on the side of the electrical
DB436475.ai
DB436474.ai

cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered
Extended front handles Extended lateral handles separately.
vv In the event of frontal installation, black or yellow/red, with or without test
position.
vv For lateral installation, black or yellow/red, without test position.
DB436476.ai

bb The front handles allow the door to be interlocked with the control rod of the
DB436477.ai

device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
3 padlocks 3 padlocks The function whereby the devices can be locked in the OFF position is available on
on direct handle on extended handle the direct control handle and the extended control handles.
It allows up to 3 padlocks to be fitted on each handle.
It is also possible to padlock the devices directly, either on the control unit using a
DB436478.ai

DB436479.ai

single padlock or a multi-padlock lockout accessory or on the lockout tab located on


the lower face of the control unit. This can accommodate up to 3 padlocks.

Using the devices as emergency switch disconnector fuse


The FuPacT switch disconnector fuse can be used as emergency cut-off devices.
single padlock 3 padlocks For this application, they must be easily visible, accessible and identifiable
directly on device on lockout tab (see standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
For the purposes of easy identification, the emergency cut-off switch disconnectors
fuse use special colors, as stipulated by the standards and different from those of the
DB436480.ai

DB436481.ai

standard version:
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
disconnector fuse are the same as those of the standard version.
Extended front handles, Extended lateral handles,
red handle on yellow front red handle on yellow front
C-22
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB 200, GSB and GSD 250, GSB and GSD 400

Connecting the devices


The FuPacT GSB200, GSD and GSB 250, GSD and GSB 400 devices are fitted with

DB436482.ai

DB436483.ai
tin-plated terminal to connect conductors fitted with cable lugs.
Connection accessories can be used to connect directly conductors without cable lugs.
The accessories are fitted to the terminal and accommodate the bare conductors.
bb FuPacT GSB 200: GS1AW43 (set of 3) or GS1AW44 (set of 4).
bb FuPacT GSD and GSB 250: GS1AW43 (set of 3) or GS1AW44 (set of 4).
bb FuPacT GSD and GSB 400: LV481203 (set of 3) or LV481204 (set of 4).
In order to protect the direct contact connections, terminal covers may be used.
For FuPacT GSB 200, GSD and GSB 250, GSD and GSB 400:
bb GS1AP43 (set of 3)
bb GS1AP44 (set of 4)

Fuse type and installation


bb GSB 200 supports BS B1 and B2 fuses compliant with IEC60269/BS88 standards.

DB436429.ai
bb GSD 250 supports DIN 1 fuses compliant with IEC60269/NFC63320 standards.

DB436497.ai
C

DB425715.eps
bb GSB 250 supports BS B1, B2 and B3 fuses compliant with IEC60269/BS88
standards.
bb GSD 400 supports DIN 2 fuses compliant with IEC60269/NFC63320 standards.
bb The GSB 400 support BS B1, B2, B3 and B4 fuses compliant with IEC60269/BS88
standards. NFC fuse BS fuse DIN fuse
Note: The fuses are not supplied with the devices.

bb For all FuPacT GSD 250 and GSD 400, the fuses are installed by rotating the
transparent protective cover, with the power supply switched off, then inserting the

DB436523.ai
fuses in the fuse holders.

DB436524.ai
bb For the FuPacT GSB 200, GSB 250 and GSB 400, the fuses are installed by
rotating the transparent protective cover, with the power supply switched off, then
installing the fuses in the housings provided for this purpose. Manual tightening is
strongly advised in order to comply with the recommended tightening torques
(consult the device manual).

External neutral module and internal neutral link


The DIN 250 and DIN 400A (LV481915 and LV481916) neutral links create a neutral
connection in the device. The links are fitted instead of a fuse.
The external neutral modules are poles fitted with a removable neutral connection
which is NOT CUT (no mechanism). DB436484.ai

They are installed directly on the left-hand side of the product on the 3-pole device.

Cone guide DB436456.ai


This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.

Auxiliary contacts / Pre cut-off


DIN link
The FuPacT GSB 200, GSD and GSB 250, GSD and GSB 400 devices can be fitted
with 8 auxiliary contacts enabling the mechanical position of the device to be indicated.
4 auxiliary contacts are fitted directly to the device (see manual) and 4 others can be
DB436430.ai

stacked on top of the first ones.


Note: if using an LV481702 direct control fitted with its auxiliary contacts protective cover, the
number of contacts that can be used is reduced to 4.
The NO or NC auxiliary contacts thus allow the ON, OFF and TEST positions of the
device to be indicated.
The TEST position is indicated if a handle WITH TEST position is used
DB436485.ai

The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.

C-23
Detailled presentation www.se.com

Presentation of the FuPacT GS range


FuPacT GSB and GSD 630, GSB and GSD 800

Functions
DB436486.ai

The FuPacT GSD and GSB 630, GSD and GSB 800 switch disconnector fuses are
used with fuses that protect electrical circuits against overloading and short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.

Format and installation


The GSD and GSB 630, GSD and GSB 800 devices are compact, optimizing the
FuPacT GSB 630 space used.
They consist of poles assembled and tested in factory as well as a housing for the
control mechanism.
The transparent covers make it possible to see the presence or absence of fuses
and their rating.
The devices are installed on a plate. The mounting points are incorporated into the
products. There is no need to add accessories to fasten the products to a plate.
C Note: The weight of the devices may require the intervention of 2 people when installing on a
plate.

Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
DB436419.ai

DB436440.ai

the fuse.
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
the fuse. One of the poles may be fitted with a neutral bar.

3 poles, 3 fuse-links 4 poles, 4 fuse-links


Controlling the devices
bb The devices can be controlled in two ways:
vv By extended frontal control with a handle installed on the door of the electrical
cabinet.
DB436488.ai
DB436487.ai

vv By extended lateral control with a handle installed on the side of the electrical
cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
Note: They must be ordered separately.
Extended front handles Extended lateral handles bb Several types of IP65 control handle are available and must be ordered separately
vv For frontal installation, black or yellow/red without test position.
vv For lateral installation, black or yellow/red without test position.
bb The front handles allow the door to be interlocked with the control rod of the
device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
DB436489.ai

The function whereby the devices can be locked in the OFF position is available on
the direct control handle and the extended control handles.
DB436490.ai

It allows up to 3 padlocks to be fitted on each handle


It is also possible to padlock the devices on the control unit directly using the
padlocking lug accessible on the front panel of the control unit. This lug can
accommodate up to 3 padlocks.
3 padlocks 3 padlocks directly
on extended handle on the device Using the devices as emergency switch disconnector fuse
The FuPacT switch disconnectors fuse can be used as emergency cut-off devices.
For this application, they must be easily visible, accessible and identifiable (see
standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
For the purposes of easy identification, the emergency cut-off switch disconnector
DB436491.ai

DB436492.ai

fuse use special colors, as stipulated by the standards and different from those of the
standard version:
bb yellow for the front face of the device or the control plate
bb red for the handle.
The performance characteristics of the FuPacT emergency cut-off switch
Extended front handles, Extended lateral handles, disconnector fuse are the same as those of the standard version.
red handle on yellow front red handle on yellow front

C-24
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB and GSD 630, GSB and GSD 800

DB436493.ai

DB436495.ai
Connecting the devices
The FuPacT GSD and GSB 630, GSD and GSB 800 devices are fitted with tin-plated
terminal to connect directly conductors fitted with cable lugs or bars.
To facilitate rear connections, the connection terminal can be rotated.
In order to protect the direct contact connections, terminal covers may be used.
For FuPacT GSD and GSB 630, GSD and GSB 800:
bb GS2AP73 (set of 3)
bb GS2AP64 (set of 4).

Fuse type and installation


bb GSD 630 and GSD 800 supports DIN 3 fuses compliant with IEC60269/
NFC63320 standards.

DB436497.ai
DB436496.ai
bb GSB 630 and GSB 800 supports BS C2 and C3 fuses respectively compliant with
IEC60269/BS88 standards.
Note: The fuses are not supplied with the devices.

bb For FuPacT GSD 630 and 800, the fuses are installed by rotating the transparent
protective cover, with the power supply switched off, then inserting the fuses in the
BS fuse DIN fuse
C
fuse holders.
bb For FuPacT GSB 630 and GSB 800, the fuses are installed by rotating the
transparent protective cover, with the power supply switched off, then installing the

DB436525.ai

DB436526.ai
fuses in the housings provided for this purpose. Manual tightening is strongly
advised in order to comply with the recommended tightening torques (consult the
device manual).

External neutral module and internal neutral bar


The DIN 630 and DIN 800A (LV481917) neutral links create a neutral connection in
the device. The links are fitted instead of a fuse.
The external neutral modules are poles fitted with a removable neutral connection
which is NOT CUT (no mechanism).

DB436502.ai
They are installed directly on the left-hand side of the product on the 3-pole device.

DB436456.ai
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
bowing of the long rods of ±10 mm.

Auxiliary contacts / Pre cut-off DIN link

FuPacT GSD and GSB 630, GSD and GSB 800 devices can be fitted with 8
auxiliary contacts enabling the mechanical position of the device to be indicated.
DB436430.ai

4 auxiliary contacts are fitted directly to the device (see manual) and 4 others can
be stacked on top of the first ones.
The NO or NC auxiliary contacts thus allow the ON and OFF positions of the
device to be indicated.
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon
as the handle is activated but before the poles are opened.
DB436503.ai

This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.

C-25
Detailled presentation www.se.com

Presentation of the FuPacT GS range


FuPacT GSB and GSD 1250

Functions
DB436504.ai

The FuPacT GSD and GSB 1250 A switch disconnector fuses are used with fuses
that protect electrical circuits against overloading and short circuits.
They provide a circuit cut-off function by means of a double break upstream and
downstream of the fuses.
They also provide a switch function allowing circuits to be cut-off when under load.

Format and installation


The GSD and GSB 1250 A devices are compact, optimizing the space used.
They consist of poles assembled and tested in factory as well as a housing for the
FuPacT GSB 1250 control mechanism
The transparent covers make it possible to see the presence or absence of fuses
and their rating
The devices are installed on a plate. The mounting points are incorporated into the
products. There is no need to add accessories to fasten the products to a plate.
Note: The weight of the devices may require the intervention of 2 people when installing on a
plate.
C Number of poles
The devices are available as 3- or 4-pole versions cut-off by the open/close control.
The 3P devices are fitted with 3 fuse holders, cut-off upstream and downstream of
the fuse.
The 4P devices are fitted with 4 fuse holders, cut-off upstream and downstream of
DB436419.ai

DB436440.ai

the fuse. One of the poles may be fitted with a neutral bar.

Controlling the devices


bb The devices can be controlled in two ways:
3 poles, 3 fuse-links 4 poles, 4 fuse-links vv By extended frontal control with a handle installed on the door of the electrical
cabinet.
vv By extended lateral control with a handle installed on the side of the electrical
cabinet.
bb The control rods are available in 3 lengths: 200, 320 or 400 m.
DB436506.ai
DB436505.ai

O
OFF
Note: They must be ordered separately.
bb Several types of IP65 control handle are available and must be ordered separately
ON

vv For frontal installation, black or yellow/red without test position


vv For lateral installation, black or yellow/red without test position
Extended front handles Extended lateral handles bb The frontal handles for the FuPacT GSD and GSB 1250 A devices are relatively
wide dual-branch handles. Remember to provide for an installation allowing the
control to be activated easily.
bb The front handles allow the door to be interlocked with the control rod of the
device. This prevents the opening of the door cabinet if the device is in the ON
position.
bb The lateral controls do not allow the door and the control rod to be interlocked.
They must not be used as a frontal control.
Lockout system
The function whereby the devices can be locked in the OFF position is available on
DB436507.ai

the direct control handle and the extended control handles.


DB436508.ai

It allows up to 3 padlocks to be fitted on each handle.


It is also possible to padlock the devices on the control unit directly using the
O
OFF

padlocking lug accessible on the front panel of the control unit. This lug can
ON

accommodate up to 3 padlocks.
3 padlocks 3 padlocks directly
Using the devices as emergency switch disconnector fuse
on extended handle on the device
The FuPacT switch disconnectors fuse can be used as emergency cut-off devices.
For this application, they must be easily visible, accessible and identifiable (see
standards and rules: VDE 0660,VDE 0113, CNOMO, etc.).
DB436509.ai

DB436510.ai

For the purposes of easy identification, the emergency cut-off switch disconnector
O
OFF

fuse use special colors, as stipulated by the standards and different from those of the
standard version:
ON

bb yellow for the front face of the device or the control plate
bb red for the handle.
Extended front handles, Extended lateral handles, The performance characteristics of the FuPacT emergency cut-off switch
red handle on yellow front red handle on yellow front disconnector fuse are the same as those of the standard version.

C-26
www.se.com
Detailled presentation
Presentation of the FuPacT GS range
FuPacT GSB and GSD 1250

DB436513.ai
DB436511.ai
Connecting the devices
The FuPacT GSD and GSB 1250 A devices are fitted with tin-plated terminal to
connect directly conductors fitted with cable lugs or bars.
To facilitate rear connections, the connection terminal can be rotated.
In order to protect connections from direct contact, terminal covers may be used.
For FuPacT GSD and GSB 1250 A:
bb GS2AP83 (set of 3)
bb GS2AP84 (set of 4).

Fuse type and installation


bb The GSD 1250 supports DIN 4 fuses compliant with IEC60269/NFC63320
standards
bb The GSB 1250 devices support BS D1 fuses compliant with IEC60269/BS88
standards.

DB436514.ai
Note: The fuses are not supplied with the devices.

DB436516.ai
DB436517.ai
bb For FuPacT GSD 1250, the fuses are installed by rotating the transparent
protective cover, with the power supply switched off, then inserting the fuses in the
fuse holders. The fuse holder terminal must be tightened for correct installation of
the fuses
bb For FuPacT GSB 1250, the fuses are installed by rotating the transparent BS fuse DIN fuse
protective cover, with the power supply switched off, then installing the fuses in the
housings provided for this purpose. Manual tightening is strongly advised in order
to comply with the recommended tightening torques (consult the device manual).

External neutral module and internal neutral link


The DIN 1250A (LV481918) neutral links create a neutral connection in the device.
The links are fitted instead of a fuse.
The external neutral modules are poles fitted with a removable neutral connection

DB436518.ai
which is NOT CUT (no mechanism).
They are installed directly on the left-hand side of the product on the 3-pole device.

DB436456.ai
DIN link
Cone guide
This accessory allows the control rod to be re-centred with regard to the hole drilled
in the door. It is fitted to the door and serves to offset a drilling discrepancy or a
DB436430.ai

bowing of the long rods of ±10 mm.

Auxiliary contacts / Pre cut-off


FuPacT GSD and GSB 1250A devices can be fitted with 8 auxiliary contacts
enabling the mechanical position of the device to be indicated.
DB436519.ai

4 auxiliary contacts are fitted directly to the device (see manual) and 4 others can be
stacked on top of the first ones.
The NO or NC auxiliary contacts thus allow the ON and OFF positions of the device
to be indicated
The auxiliary contacts also serve to indicate the pre cut-off of the device, as soon as
the handle is activated but before the poles are opened.
This allows a charge to be stopped before cutting the main power supply.
bb References GS1AM110 and GS1AM101 have 1 auxiliary contact (NO or NC)
+ 2 plastic tappets.
bb References ZBE101 and ZBE102 are the auxiliary contacts alone.
bb Reference LV481110 is a packet of 10 plastic tappets.

C-27
Dimensions and connection www.se.com

FuPacT GS 32 A
Dimensions

Dimensions
GSC 32 A with direct front handle GSB 32 A with direct front handle
112 96 112
44 15 44 96
DB436135.eps

DB436136.eps

DB436137.eps
19 6.5 5.2 35 19 6.5 5.2 15

14 14 14

45 X X 45 X X X
98 98
90°
65°

65 8.5 21.5 65 8.5


21.5 17 98 83
Z Y Z Y Y

GSC 32 A with extended front handle GSB 32 A with extended front handle
45 102 min. [1] 45 102 min. [1] Ø78

C
DB436138.eps

DB436139.eps

65°

DB436140.eps
35 35
X X X
14 49 14 49 14
90°

70
Z Z Y

[1] W
 ith 1 or 2 auxiliary contacts GS1 AM1pp: 130 mm.
With 3 or 4 auxiliary contacts GS1 AM1pp: 155 mm.

GSC 32 A with extended lateral handle GSB 32 A with extended lateral handle
96 36 min. 44 96 36 min. 44
Ø78
DB436141.eps

DB436142.eps

DB436143.eps

90°

X X X

52.5 52.5 70 19

Y Y Z

C-28
www.se.com
Dimensions and connection
FuPacT GS 32 A
Mounting and front panel cut-outs

Mounting
On the backplate On DIN rail
37.5
DB436144.eps

DB436145.eps
=

79.5 X 35 X

2 Ø5
Y Y

Front panel cut-outs


Extended front handle
28
4 Ø7

C
DB436146.eps

40
X

Ø37

Extended lateral handle


28
DB436147.eps

4 Ø7

40 X

Ø37

19
Z

Accessories
Auxiliary contacts

[a]
DB436148.eps

49

88.5
112
Z
[c] 1 to 4 auxiliary contacts GS1 AM1pp.

C-29
Dimensions and connection www.se.com

FuPacT GS 50/63 A
Dimensions

Dimensions
Direct front handle
6.5
DB436149.eps

DB436150.eps

DB436151.eps
65°
142
X X X
118

90°
31 B 5.4
(3P)
A C 18 116
204 D (3P)
B
(4P)
D (4P)
Z Y Y

Extended front handle


C 45 E min. [1]
Ø78
DB436152.eps

DB436153.eps
65°

X X

59
90°

70
Z Y

[1] FuPacT GS 50 A : 1 auxiliary contact GS1 AM1pp: E + 23.5 mm, 2 auxiliary contacts GS1 AM1pp: E + 47 mm.

Extended lateral handle


D (4P)
20 min.
D (3P) 45
DB436154.eps

DB436155.eps

230 max.
Ø78

90°

X X

70 31

Y Z

Type A B C D E min. F G H I
GSC 50 A 3P 87 31 45 121 100 27 110.5 134 31
4P 87 31 45 148 100 54 110.5 134 -
GSB/GSD 63 A 3P 116.5 36 50 136 139 32 108.5 132 36
4P 116.5 36 50 168 139 64 108.5 132 -

C-30
www.se.com
Dimensions and connection
FuPacT GS 50/63 A
Mounting and front panel cut-outs

Mounting
On the backplate On DIN rail
3 poles 4 poles
F C F C
4 Ø5 4 Ø5
DB436156.eps

DB436157.eps
= =

106 X 106 X 35 X

= =

Y Y Y

Front panel cut-outs


Extended front handle
28

C
DB436158.eps

4 Ø7

40 X

Ø37

Extended lateral handle


28
DB436159.eps

4 Ø7

40 X

Ø37

31
Z

Accessories
Auxiliary contacts External neutral module
[a]
DB436160.eps

DB436161.eps

X X

59

G I Y
H
Z
[c] 1 to 4 auxiliary contacts GS1 AM1pp.
Type A B C D E min. F G H I
GSC 50 A 3P 87 31 45 121 100 27 110.5 134 31
4P 87 31 45 148 100 54 110.5 134 -
GSB/GSD 63 A 3P 116.5 36 50 136 139 32 108.5 132 36
4P 116.5 36 50 168 139 64 108.5 132 -

C-31
Dimensions and connection www.se.com

FuPacT GS 100/160 A
Dimensions

Dimensions
Direct front handle
K K K
[a] (4P)
DB436162.eps

DB436164.eps
DB436163.eps

65°
142
X H B J X X

90°

116

2.5 I C L
(3P)
31 C D E F
C A
(4P)
G (3P)
204 G (4P)
Z Y Y
[a] Terminal cover.

Extended front handle


45 M min.
Ø78
DB436165.eps

DB436166.eps

65°

X X

N 90°

125
Z Y

Extended lateral handle


G (4P)
20 min.
G (3P) 45
230 max.
DB436168.eps
DB436167.eps

Ø78
90°

X X

125 31
Y Z

Type A B C D E min. F G H I J K L Ø M min. N


GSB 100 A 3P 116 162 40 5.4 54 18 148 268 19.5 141 36 20 8.5 135 81
4P 116 162 40 5.4 54 18 184 268 19.5 141 36 20 8.5 135 81
GSC 125 A 3P 116 162 40 5.4 54 18 148 268 19.5 141 36 20 8.5 135 81
4P 116 162 40 5.4 54 18 184 268 19.5 141 36 20 8.5 135 81
GSD 125 A 3P 126.5 162 40 5.4 54 18 148 268 19.5 141 36 20 8.5 135 81
4P 126.5 162 40 5.4 54 18 184 268 19.5 141 36 20 8.5 135 81
GSD 160 A 3P 126.5 162 40 5.4 54 18 148 268 19.5 141 36 20 8.5 135 81
4P 126.5 162 40 5.4 54 18 184 268 19.5 141 36 20 8.5 135 81
GSB 160 A 3P 136.5 162 54 5.4 64 18 190 268 19.5 141 50 20 8.5 145 81
4P 136.5 162 54 5.4 64 18 240 268 19.5 141 50 20 8.5 145 81

C-32
www.se.com
Dimensions and connection
FuPacT GS 100/160 A
Mounting and front panel cut-outs

Mounting
On the backplate
3 poles P E 4 poles P E
4Ø 4Ø
DB436169.eps

= =
O X O X

= =

Y Y

Front panel cut-outs


Extended front handle
28
DB436170.eps

4 Ø7

40 X C
Ø37

Extended lateral handle


28
DB436171.eps

4 Ø7

40 X

Ø37

31
Z

Accessories
Auxiliary contacts External neutral module
[b]
DB436172.eps

DB436173.eps

X X

108.5 Q Y
132 Z
[b] 1 to 4 auxiliary contacts GS1 AM1pp.

Type E O P Ø Q
GSB 100 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSC 125 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSD 125 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSD 160 A 3P 54 127 36 5 40
4P 54 127 72 5 -
GSB 160 A 3P 64 140 50 5 54
4P 64 140 100 5 -

C-33
Dimensions and connection www.se.com

FuPacT GS 200/400 A
Dimensions

Dimensions
Direct front handle
J J J
(4P)

DB436175.eps

DB436176.eps
[a]
DB436174.eps

4 Ø11

65°
142
X X X
F B I

90°

136

C
G H C K
(3P)
31 C 6.4 D 25
(4P)
A E (3P)
208 E (4P)
Z Y Y
[a] Terminal cover.

Extended front handle


45 L min.
DB436177.eps

DB436178.eps

Ø78

65°
X X

M 90°

125

Z Y

Extended lateral handle


E (4P)
20 min.
E (3P) 45
230 max.
DB436180.eps

Ø78
DB436179.eps

90°

X
125 31

Type A B C D E F G H I J K L min. M N O P
GSB 200 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 250 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 400 A 3P 149 205 70 91 252 355 3 20 175 66 50 157 102.5 172 66 70
4P 149 205 70 91 318 355 3 20 175 66 50 157 102.5 172 132 -

C-34
www.se.com
Dimensions and connection
FuPacT GS 200/400 A
Mounting and front panel cut-outs

Mounting
On the backplate
3 poles 4 poles
4 Ø6 O D O D
DB436181.eps

4 Ø6

= =
N X N X

= =

Y Y

Front panel cut-outs


Extended front handle Extended lateral handle
28 28

C
DB436182.eps

DB436183.eps
4 Ø7
4 Ø7

40 X X
40
Ø37
Ø37

31
Z

Accessories
Auxiliary contacts External neutral module

[b]
DB436184.eps

DB436185.eps

X X

108.5 P
132 Z Y
[b] 1 to 8 auxiliary contacts GS1 AM1pp.
1 to 4 auxiliary contacts GS1 AM1pp with direct front handle.

Type A B C D E F G H I J K L min. M N O P
GSB 200 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 250 A 3P 146 195 64 86 234 345 2.5 19.5 166 60 32 154 97.5 162 60 64
4P 146 195 64 86 294 345 2.5 19.5 166 60 32 154 97.5 162 120 -
GS 400 A 3P 149 205 70 91 252 355 3 20 175 66 50 157 102.5 172 66 70
4P 149 205 70 91 318 355 3 20 175 66 50 157 102.5 172 132 -

C-35
Dimensions and connection www.se.com

FuPacT GS 630/800 A
Dimensions

Dimensions
GSB 630 A / GSD 630 A / GSB 800 A / GSD 800 A
3 poles 94 94 4 poles 94 94 94
DB436186.eps

DB436188.eps
DB436187.eps
[a]
6 Ø13 8 Ø13
[b]
=
7

300 300
90 471 X X X
260 260
7
=

7 51 35 51 35
59
364 458
C 250
79.5

Z Y Y
[a] Terminal cover.
[b] Rear access connector plates.
Extended front handle
61 265 min.
DB436189.eps

DB436190.eps

Ø78 65°
22

X X
22
90°
150
210

Z Y

Extended lateral handle


458 (4P)
364 (3P) 15 min. 61
DB436192.eps
DB436191.eps

Ø78
90°

X X

210 79.5

Y Z

C-36
www.se.com
Dimensions and connection
FuPacT GS 630/800 A
Mounting and front panel cut-outs

Mounting
On the backplate
3 poles 284 34 4 poles 378 34
DB436193.eps

11 9 11 9

= =
X X
250 250

= =

Y Y

Front panel cut-outs


Extended front handle
28

C
DB436194.eps

Ø37 4 Ø7

40
22 X

Extended lateral handle


DB436195.eps

28
4 Ø7

40 X

Ø37

79.5

Accessories
Auxiliary contacts External neutral module
[c]
DB436197.eps
DB436196.eps

X X

150

166.5 106 Y
190 Z
[c] 1 to 8 auxiliary contacts GS1 AM1pp.

C-37
Dimensions and connection www.se.com

FuPacT GS 1250 A
Dimensions

Dimensions
GSB 1250 A / GSD 1250 A
3 poles 4 poles
120 120 120 120 120
DB436198.eps

DB436199.eps

DB436200.eps
[a]

[b]
12 Ø13 16 Ø13
=
7

300
90 471 X X X
260
7
=

7 25 77 25 77

C 59
79.5
40
442
35 40
562
35

289
Z Y Y
[a] Terminal cover.
[b] Rear access connector plates.
Extended front handle
61 304 min.
DB436201.eps

DB436202.eps

Ø78 90°
22

X X
22
150

= =
Z 300
Y

Extended lateral handle


562 (4P)
442 (3P) 15 min. 61
DB436203.eps

DB436204.eps

Ø78
90°

X X

210 79.5

Y Z

C-38
www.se.com
Dimensions and connection
FuPacT GS 1250 A
Mounting and front panel cut-outs

Mounting
On the backplate
3 poles 362 34 4 poles 482 34
DB436205.eps

11 9 11 9

= =
X X
250 250

= =

Y Y

Front panel cut-outs


Extended front handle
28

C
DB436206.eps

4 Ø7
Ø37

40
X

22

Extended lateral handle


DB436207.eps

28
4 Ø7

40 X

Ø37

79.5

Accessories
Auxiliary contacts External neutral module
[c]
DB436208.eps

DB436209.eps

X X

150

166.5 132 Y
190 Z
[c] 1 to 8 auxiliary contacts GS1 AM1pp.

C-39
Dimensions and connection www.se.com

FuPacT GS 32 to 1250 A
Class II installation

Minimun Air distance to respect between the protective screen and the plastic covers of
fuses in a Class II installation
GS 32 A
Reference L min.
LV481503 35
DB436542.ai

LV481504
LV481603
LV481604

GS 50 A / GS 63 A / GS 100 A / GS 125 A / GS 160 A

C Reference
LV481513
L min.
40
DB436543.ai

LV481514
LV481403
LV481404
LV481613
LV481614
LV481623 35
LV481624
LV481413
LV481414
L LV481523
LV481524
LV481633
LV481634
LV481423
LV481424

GS 200 A / GS 250 A / GS 400 A


Reference L min.
LV481643 32
DB436544.ai

LV481644
LV481653
LV481654
LV481663
LV481664
LV481433
LV481434
LV481443
LV481444

GS 630 A / GS 800 A / GS 1250 A


Reference L min.
LV481453 30
DB436545.ai

LV481454
LV481463
LV481464
LV481673
LV481674
LV481683
LV481684
LV481693
LV481694
LV481473
LV481474
L

C-40
www.se.com

Catalog numbers

ISFT100N.....................................................................................D-2
Devices and accessories................................................................. D-2

ISFT100........................................................................................D-3
Devices and accessories................................................................. D-3

ISFT160........................................................................................D-4
Devices and accessories................................................................. D-4

ISFT250 to ISFT630.................................................................D-5
Devices and accessories................................................................. D-5

ISFL160........................................................................................D-6
Devices and accessories................................................................. D-6

ISFL250 to ISFL1250...............................................................D-8
Devices and accessories................................................................. D-8

GSC32 - GSC50 - GSC125................................................ D-10


Devices........................................................................................... D-10
Accessories.................................................................................... D-11

GSD 63 to 1250...................................................................... D-12


Devices........................................................................................... D-12 D
Accessories.................................................................................... D-13

GSB 32 to 1250...................................................................... D-14


Devices........................................................................................... D-14
Accessories.................................................................................... D-15

FuPacT protection components...................................... D-16


Cartridge fuses type aM................................................................. D-16
Cartridge fuses type gG................................................................. D-17

Other chapters
Presentation....................................................................................................2
FuPacT ISFT............................................................................................... A-1
FuPacT ISFL............................................................................................... B-1
FuPacT GS.................................................................................................C-1

D-1
Catalog numbers
ISFT100N
Devices and accessories

ISFT100N 3P fixed front-connected


Basic device for mounting on a backplate
Connection via 2.5 to 50 mm2 cable connectors LV480750
DB424947.eps

Basic device for mounting on busbars


Hook-on connection to 60 mm busbars Upstream distribution LV480751
Downstream distribution LV480752
DB424948.eps

Accessories
DIN rail fixing kit LV480753
DB120643.eps

D Support profile laterally attachable Set of 2 LV480754


DB120650.eps

Terminal shield Set of 2 LV480756


DB120651.eps

Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480755
DB120652.eps

D-2
Catalog numbers
ISFT100
Devices and accessories

ISFT100 3P fixed front-connected


Basic device for mounting on a backplate
Connection via 1.5 to 50 mm2 cable connectors LV480800
DB424808.eps

Accessories
Mounting accessories
Accessory for mounting on a DIN rail 49877
DB401325.eps

Escutcheon (not compatible with For 1 device 49878


feeding busbars) For 2 devices 49879
DB401326.eps

Connection accessories
Distribution connector 3 x 16 mm2 Set of 3 49860

D
DB401327.eps

Feeding busbar to supply 2 devices 49861


DB401328.eps

Feeding busbar to supply 3 devices 49862


DB401329.eps

Feeding busbar to supply 4 devices 49863


DB401330.eps

Incoming connector (25 to 95 mm2) for feeding busbars Set of 3 49865


DB401331.eps

Electrical auxiliaries
Auxiliary changeover contact NO + NC 49885
DB414827.eps

D-3
Catalog numbers
ISFT160
Devices and accessories

ISFT160 3P fixed front-connected


Basic device for mounting on a backplate
M8 terminals LV480801
2,5 to 95 mm² cable connectors (box clamp) LV480802
DB424809.eps

Basic device for mounting on busbars with turnable hooks


ISFT160 LV480803
DB424810.eps

Accessories
Mounting accessories
Handle with electronic fuse monitor LV480810

Support profile laterally attachable LV480817


DB425101.eps

DB425779.eps

D
Terminal shields LV480819
DB425780.eps

Connection accessories
Incoming connector LV480818
DB425785.eps

Feeding busbars for 2 devices LV480811


for 3 devices LV480812
for 4 devices LV480813
DB425784.eps

Distribution connector 3 x 16 mm² for 1,5 to 50 mm² cable connectors LV480814


DB425781.eps

Pressure plate for multiple-use terminal from 6 to 50mm² LV480815


DB425783.eps

Pressure plate with contact prism for multiple-use terminal with Cu/Alu conductors LV480816
DB425782.eps

from 6 to 70 mm²

Electrical auxiliaries
Auxiliary changeover contact NO+NC LV480755
DB425100.eps

D-4
Catalog numbers
ISFT250 to ISFT630
Devices and accessories

ISFT250 to ISFT630 3P fixed front-connected


Basic device for mounting on a backplate
ISFT250 LV480804
ISFT400 LV480806
ISFT630 LV480808
DB424811.eps

Basic device for mounting on busbars with turnable hooks


ISFT250 LV480805
ISFT400 LV480807
DB425793.eps

Accessories
Mounting accessories
Handle with electronic fuse monitor ISFT250 LV480821
DB425786.eps

ISFT400 LV480825
ISFT630 LV480828

Support profile laterally attchable LV480832


D
DB425787.eps

Connection accessories
Pressure plate with contact from 70 to 150 mm2 ISFT250 LV480822
DB425788.eps

prism for multiple-use terminal


with Cu/Al conductors from 120 to 240 mm2 ISFT400 LV480826

from 150 to 300 mm2 ISFT630 LV480829


ISFT250 box clamp from 35 to 150 mm2 LV480823
DB425789.eps

35...150 mm2 re/rm


50 to 150 mm2 se/sm

ISFT400 and ISFT 630 box clamp LV480830


95...300 mm2 re/rm
120 to 300 mm2 se/sm
Terminal shields ISFT250 LV480824
DB425790.eps

ISFT400 LV480827
ISFT630 LV480831

Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480833
DB425791.eps

D-5
Catalog numbers
ISFL160
Devices and accessories

ISFL160 1-pole switchable fixed front-connected


Basic device for mounting on busbars
Direct connection to 185mm busbars (M12) LV480900
DB419490.eps

ISFL160 3-pole switchable fixed front-connected


Basic device for mounting on busbars
Direct hook-on connection to 60 mm busbars Screws M8 LV480850
Terminals 95 mm2 LV480851
Direct connection to 100 mm busbars Screws M8 LV480852
Terminals 95 mm2 LV480853
DB401216.eps

Conversion kit for connection to busbars (for ISFL160 direct connection)


Direct connection to 185 mm busbars LV480854
D Direct connection to 185 mm busbars for 2 ISFL160 devices LV480855
DB401237.eps

Accessories
Sideframe door cut out - 850 mm LV480868
Sidewise angle bracket for side frame (x4) LV480869
DB401238.eps
DB401239.eps

Length adaptor LV480870


Empty plastic box (46 x 46 mm) LV480878
DB401241.eps
DB401240.eps

Bank panel cover LV480871


DB401242.eps

Contact hooks for ISFL 1-pole switchable Set of 3 LV480905


DB419491.eps

Connection (accessories for standard M8 terminals)


Lugs for 95 mm2 copper cables Set of 3 28951
DB401208.eps

Connectors for Cu/Al bare cables 1.5 x 95 mm2 Set of 3 LV480861


DB401243.eps

for flexible bars 12 x 6 mm Set of 3 LV480862


DB401244.eps

D-6
Catalog numbers
ISFL160
Devices and accessories

Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480873
DB401245.eps

1 current transformer 150/5 A class 1 5 VA Set of 1 LV480904


for ISFL 1-pole switchable
DB419492.eps

Single block with 3 current 150/5 A class 1 1.5 VA Set of 1 LV480881


transformer for ISFL 3-pole switchable 150/1 A class 1 2.5 VA Set of 1 LV480882
DB401246.eps

Single block with current 150/5 A class 1 1.5 VA Set of 1 LV480883


transformer for ISFL 3-pole switchable 150/1 A class 1 2.5 VA Set of 1 LV480884

Fuse monitor for ISFL 3-pole switchable LV480877


DB401217.eps

D-7
Catalog numbers
ISFL250 to ISFL1250
Devices and accessories

ISFL250 to ISFL630 1-pole switchable


Basic device for mounting on busbars
Direct connection to 185 mm busbars (screw M12) ISFL250 LV480901
ISFL400 LV480902
ISFL630 LV480903
DB419493.eps

Hooks for mounting without drilling LV480859


DB401249.eps

ISFL250 to ISFL630 3-pole switchable


Basic device for mounting on busbars
Direct connection to 185 mm busbars ISFL250 LV480856
ISFL400 LV480857

D ISFL630
ISFL1250
LV480858
LV480875
DB401247.eps

Hooks for mounting without drilling LV480859


DB401249.eps

With fuse monitor


Fuse monitor (direct connection ISFL250 LV480863
to 185 mm busbars) ISFL400 LV480864
ISFL630 LV480865
ISFL1250 LV480876
DB401248.eps

D-8
Catalog numbers
ISFL250 to ISFL1250
Devices and accessories

Accessories
Sideframe door cut out - 850 mm LV480868
Sidewise angle bracket for side frame Set of 4 LV480869
DB401238.eps
DB401239.eps

Empty plastic box (72 x 72 mm) LV480879 [1]


DB401251.eps

Empty plastic box (96 x 96 mm) LV480880 [1]

Blank panel cover LV480872


DB401250.eps

Connection (accessories for standard M12 terminals)


Connectors For Cu/Al bare cable 1 x 35 to 300 mm2 Set of 3 LV480867 [1]
DB401277.eps

Db105281.eps

For Cu/Al bare cable 2 x 50 to 185 mm 2


Set of 3 49895 [1]
For Cu/Al cable 4 x 240 mm 2
Set of 3 LV480890 [2]

D
DB421666.eps

Screws with plastic support Set of 3 LV480866 [1]


DB401252.eps

Coupling kit ISFL250-630 LV480891 [1]


DB425792.eps

Electrical auxiliaries
Auxiliary changeover contact NO + NC LV480874
DB401278.eps

Current transformer 150/5 class 1 2.5 VA Set of 1 LV480885


250/5 class 1 5 VA Set of 1 LV480886
DB401279.eps

400/5 class 1 5 VA Set of 1 LV480887


600/5 class 1 5 VA Set of 1 LV480888
Click-lock cable transformers Set of 1 LV480889
DB401280.eps

[1] Except for ISFL1250.


[2] Only for ISFL1250.

D-9
Catalog numbers www.se.com

GSC32 - GSC50 - GSC125


Devices

GSC32 - GSC50 - GSC125


Basic Device : Front or lateral control
Switch/Type of fuse 3P/3F 4P/3F+N
DB436395.ai

DB436420.ai
DB436419.ai
GSC32 / NFC LV481503 LV481504
(10 x 38), 32 A

Switch/Type of fuse 3P/3F 4P/4F


DB436396.ai

DB436419.ai

DB436440.ai
GSC50 / NFC LV481513 LV481514
(14 x 51), 50 A
GSC125 / NFC LV481523 LV481524
(22 x 58), 125 A

Direct handle with Test position


32 A 50 and 125 A
Front GS1AH103 LV481701 [1]
DB436396-bis.ai
DB436397.ai

ON

D
OFF

Extended Rotary Handle IP 65


Front handle
32 and 50 A 125 A
Front Black Handle GS2AH510 GS2AH530
Front Red/Yellow Handle GS2AH520 GS2AH540
DB436394.ai

Front Black Handle + test position GS2AHT510 GS2AHT530


Front Red/Yellow Handle + test position GS2AHT520 GS2AHT540

Lateral handle
32 and 50 A 125 A
Lateral Black Handle GS2AH210 GS2AH230
Lateral Red/Yellow Handle GS2AH220 GS2AH240
DB436398.ai

Accessories
Shaft
32 and 50 A 125 A
200 mm shaft GS2AE82 GS2AE22
DB436399.ai

320 mm shaft GS2AE8 GS2AE2


400 mm shaft GS2AE81 GS2AE21

Guide cone
32 to 1250 A
GS2AEH12
DB436400.ai

[1] Available Q4 2020.

Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.

D-10
www.se.com
Catalog numbers
GSC32 - GSC50 - GSC125
Accessories

Accessories - GSC32 - GSC50 - GSC125


Connection
External neutral module For GSC50 LV481900
For GSC125 LV481902
DB436401.ai

Internal neutral link For GSC50 LV481911


For GSC125 LV481912
DB436432.ai

Electrical auxiliaries (Compatible with all GSC products)


Auxiliary contacts
1 NO contact with 2 accessories GS1AM110
1 NC contact with 2 accessories GS1AM101
DB436403.ai

Set of 5 NO contacts ZBE101


Set of 5 NC contacts ZBE102
DB436402.ai

x10
Set of 10 accessories for auxiliary contact LV481110
D
DB436404.ai

Cable connectors
3P (set of 3) 4P (set of 4)
For GSC125 GS1AW33 GS1AW34
DB436405.ai

Terminal shield
3P (set of 3) 4P (set of 4)
For GSC125 GS1AP33 GS1AP34
DB436406.ai

Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.

D-11
Catalog numbers www.se.com

GSD 63 to 1250
Devices

GSD63 - GSD125 - GSD160 - GSD250 - GSD400 - GSD630 - GSD800 - GSD1250


Basic Device : Front or lateral control
Switch/Type of fuse 3P/3F 4P/4F
DB436410.ai

DB436419.ai

DB436440.ai
GSD63/DIN 000 LV481403 LV481404
63 A
GSD125/DIN 00 LV481413 LV481414
125 A
GSD160/DIN 00 LV481423 LV481424
160 A
GSD250/DIN 1 LV481433 LV481434
250 A
GSD400/DIN 2 LV481443 LV481444
400 A

GSD630/DIN 3 LV481453 LV481454


630 A
DB436411.ai

GSD800/DIN 3 LV481463 LV481464


800 A
GSD1250/DIN 4 LV481473 LV481474
1250 A

Direct handle with Test position


D 63 to 160 A 250 to 400 A 630 to 800 A 1250 A
DB436412.ai

Front LV481701 [1] LV481702 [1] - -

Extended Rotary Handle IP 65


Front handle
63 A 125 to 400 A 630 to 800 A 1250 A
Front Black Handle GS2AH510 GS2AH530 GS2AH550 GS2AH570
ON
I Front Red/Yellow Handle GS2AH520 GS2AH540 GS2AH560 GS2AH580
DB436409.ai

Front Black Handle GS2AHT510 GS2AHT530 - -


OFF

+ test position
Front Red/Yellow Handle GS2AHT520 GS2AHT540 - -
+ test position
Lateral handle
63 A 125 to 400 A 630 to 1250 A
Lateral Black Handle GS2AH210 GS2AH230 GS2AH250
Lateral Red/Yellow Handle GS2AH220 GS2AH240 GS2AH260
DB436413.ai

Accessories
Shaft
63 to 400 A 630 to 1250 A
200 mm shaft GS2AE22 GS2AE52
DB436399.ai

320 mm shaft GS2AE2 GS2AE5


400 mm shaft GS2AE21 GS2AE51

Guide cone
63 to 1250A
GS2AEH12
DB436400.ai

[1] Available Q4 2020.

Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.

D-12
www.se.com
Catalog numbers
GSD 63 to 1250
Accessories

Accessories - GSD63 - GSD125 - GSD160 - GSD250 - GSD400 - GSD630 - GSD800 - GSD1250


Connection
External neutral module For GSD63 LV481901
For GSD100 to GSD160 LV481902
DB436414.ai

For GSD200 to GSD250 LV481904


For GSD400 LV481905
For GSD630 to GSD800 LV481906
For GSD1250 LV481907

Internal neutral link For GSD63 to GSD160 LV481913


For GSD250 LV481915
DB436433.ai

For GSD400 LV481916


For GSD630 to GSD800 LV481917
For GSD1250 LV481918

Electrical auxiliaries (Compatible with all GSD products)


Auxiliary contacts
1 NO contact with 2 accessories GS1AM110
1 NC contact with 2 accessories GS1AM101
DB436403.ai

Set of 5 NO contacts ZBE101


Set of 5 NC contacts ZBE102
DB436402.ai

x10
Set of 10 accessories for auxiliary contact LV481110
D
DB436404.ai

Cable connectors
3P (set of 3) 4P (set of 4)
DB436405.ai

For GSD100 to GSD160 GS1AW33 GS1AW34


For GSD200 to GSD250 GS1AW43 GS1AW44
For GSD400 LV481203 LV481204
Terminal shield [1]
3P (set of 3) 4P (set of 4)
DB436406.ai

For GSD125 to GSD160 GS1AP33 GS1AP34


For GSD250 to GSD400 GS1AP43 GS1AP44
For GSD630 to GSD 800 GS2AP73 GS2AP64
For GSD1250 GS2AP83 GS2AP84
[1] The use of terminal shields is mandatory at 690 V AC.

Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.

D-13
Catalog numbers www.se.com

GSB 32 to 1250
Devices

GSB32 - GSB63 - GSB100 - GSB160 - GSB200 - GSB250 - GSB400 - GSB630 - GSB800 - GSB1250
Basic Device : Front or lateral control
Switch/Type of fuse 3P/3F 4P/3F+N
DB436416.ai

DB436420.ai
DB436419.ai
GSB32 - BS A1 LV481603 LV481604
32A

Switch/Type of fuse 3P/3F 4P/4F


DB436410.ai

DB436419.ai

DB436440.ai
GSB63 - BS A2/A3 LV481613 LV481614
63A
GSB100 - BS A4 LV481623 LV481624
100A
GSB160 - BS A4 LV481633 LV481634
160A
GSB200 - BS B1/B2 LV481643 LV481644
200A
GSB250 - BS B1/B2/B3 LV481653 LV481654
250A
GSB400 - BS B1/B2/B3/B4 LV481663 LV481664
400A

D GSB630 - BS C2 LV481673 LV481674


630A
DB436411.ai

GSB800 - BS C3 LV481683 LV481684


800A
GSB1250 - BS D1 LV481693 LV481694
1250A

Direct handle with Test position


32 A 63 to 160 A 200 to 400 A
Front GS1AH103 LV481701 [1] LV481702 [1]
DB436412.ai

Extended Rotary Handle IP 65


Front handle
32 to 63 A 125 to 400 A 630 to 800 A 1250 A
Front Black Handle GS2AH510 GS2AH530 GS2AH550 GS2AH570
ON
I Front Red/Yellow Handle GS2AH520 GS2AH540 GS2AH560 GS2AH580
DB436409.ai

Front Black Handle GS2AHT510 GS2AHT530 - -


OFF

+ test position
Front Red/Yellow Handle GS2AHT520 GS2AHT540 - -
+ test position
Lateral handle
63 A 125 to 400 A 630 to 1250 A
Lateral Black Handle GS2AH210 GS2AH230 GS2AH250
DB436413.ai

Lateral Red/Yellow Handle GS2AH220 GS2AH240 GS2AH260

[1] Available Q4 2020.

Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.

D-14
www.se.com
Catalog numbers
GSB 32 to 1250
Accessories

Accessories
Shaft
32 A 63 to 400 A 630 to 1250 A
200 mm shaft GS2AE82 GS2AE22 GS2AE52
DB436399.ai

320 mm shaft GS2AE8 GS2AE2 GS2AE5


400 mm shaft GS2AE81 GS2AE21 GS2AE51

Guide cone
63 to 1250A
GS2AEH12
DB436400.ai

Accessories - GSB32 - GSB63 - GSB100 - GSB160 - GSB200 - GSB250 - GSB400 - GSB630 - GSB800 - GSB1250
Connection
External neutral module For GSB63 LV481901
For GSB100 LV481902
DB436414.ai

For GSB160 LV481903


For GSB200 - GSB250 LV481904
For GSB400 LV481905
For GSB630 - GSB800 LV481906
For GSB1250 LV481907

Electrical auxiliaries (Compatible with all GSB products)


Auxiliary contacts
1 NO contact with 2 accessories
1 NC contact with 2 accessories
GS1AM110
GS1AM101 D
DB436403.ai

Set of 5 NO contacts ZBE101


Set of 5 NC contacts ZBE102
DB436402.ai

Set of 10 accessories for auxiliary contact LV481110


x10
DB436404.ai

Cable connectors
3P (set of 3) 4P (set of 4)
DB436405.ai

For GSB100 to GSB160 GS1AW33 GS1AW34


For GSB200 to GSB250 GS1AW43 GS1AW44
For GSB400 LV481203 LV481204
Terminal shield [1]
3P (set of 3) 4P (set of 4)
DB436406.ai

For GSB125 to GSB160 GS1AP33 GS1AP34


For GSB200 to GSB400 GS1AP43 GS1AP44
For GSB630 to GSB 800 GS2AP73 GS2AP64
For GSB1250 GS2AP83 GS2AP84
[1] The use of terminal shields is mandatory at 690 V AC.

Note: FuPacT GS and its accessories are not compatible with the FuPacT INF former range.

D-15
Catalog numbers www.se.com

FuPacT protection components


Cartridge fuses type aM
For protection of equipment with current peaks
Fuse type Maximum Rating Set of Fuses without striker
rated Unit reference Weight
voltage
V A kg
DB425714.eps

Cylindrical a 500 20 10 DF2CA20 0.010


10 x 38 a 400 25 10 DF2CA25 0.010
32 10 DF2CA32 0.010
DF2 CAppp Cylindrical a 690 20 10 DF2EA20 0.020
14 x 51 25 10 DF2EA25 0.020
a 500 32 10 DF2EA32 0.020
DB425715.eps

40 10 DF2EA40 0.020
50 10 DF2EA50 0.020
Cylindrical a 690 20 10 DF2FA20 0.045
22 x 58 25 10 DF2FA25 0.045
DF2 EAppp 32 10 DF2FA32 0.045
40 10 DF2FA40 0.045
50 10 DF2FA50 0.045
63 10 DF2FA63 0.045
80 10 DF2FA80 0.045
DB425716.eps

a 500 100 10 DF2FA100 0.045


125 10 DF2FA125 0.045

DF2 FApp

Fuse type Maximum Rating Set of Fuses without striker


rated
Unit reference Weight
voltage
V A kg
Blade a 690 25 3 DF2FGA25 0.160
NH 000
32 3 DF2FGA32 0.160
40 3 DF2FGA40 0.160
50 3 DF2FGA50 0.160
63 3 DF2FGA63 0.160
DB425717.eps

DF2 GApppp Blade a 690 80 3 DF2FGA80 0.160


NH 00 100 3 DF2FGA100 0.160
125 3 DF2FGA125 0.160
Blade a 690 50 3 DF2GA1051 0.230
NH 0 63 3 DF2GA1061 0.230
80 3 DF2GA1081 0.230
DB430663.eps

100 3 DF2GA1101 0.230


125 3 DF2GA1121 0.230
160 3 DF2GA1161 0.230
a 500 200 3 DF2GA1201 0.230
Blade a 690 160 3 DF2HA1161 0.400
DF4 GApppp NH 1 200 3 DF2HA1201 0.400
250 3 DF2HA1251 0.400
a 500 315 3 DF2HA1311 0.400
Blade a 690 250 3 DF2JA1251 0.560
NH 2 315 3 DF2JA1311 0.560
400 3 DF2JA1401 0.560
DB425719.eps

a 500 500 3 DF2JA1501 0.560


Blade a 690 400 1 DF2KA1401 0.850
NH 3 500 1 DF2KA1501 0.850
a 500 630 1 DF2KA1631 0.850
[1] Set of 3.

DF2 JApppp

D-16
www.se.com
Catalog numbers
FuPacT protection components
Cartridge fuses type gG
For protection of circuits without significant current peaks
Fuse Maximum Rating Set of Fuses without striker
type rated voltage Unit reference Weight

V A kg
DB425714.eps

Cylindrical a 500 20 10 DF2CN20 0.010


10 x 38 a 400 25 10 DF2CN25 0.010
32 10 DF2CN32 0.010
DF2 CNpp Cylindrical a 690 20 10 DF2EN20 0.020
14 x 51 25 10 DF2EN25 0.020
a 500 32 10 DF2EN32 0.020
DB425715.eps

40 10 DF2EN40 0.020
50 10 DF2EN50 0.020
Cylindrical a 690 20 10 DF2FN20 0.045
22 x 58 25 10 DF2FN25 0.045
DF2 ENpp 32 10 DF2FN32 0.045
40 10 DF2FN40 0.045
50 10 DF2FN50 0.045
63 10 DF2FN63 0.045
80 10 DF2FN80 0.045
DB425716.eps

a 500 100 10 DF2FN100 0.045

DF2 FNpp

Fuse type Maximum Rating Set of Fuses without striker


rated
Unit reference Weight
voltage
V A kg
Blade a 690 25 3 DF2FGN25 0.160
NH 000 32 3 DF2FGN32 0.160
40 3 DF2FGN40 0.160
50 3 DF2FGN50 0.160
63 3 DF2FGN63 0.160
DB425717.eps

DF2 GNpppp 80 3 DF2FGN80 0.160


> 500 100 9 DF2FGN100 0.160
Blade a 690 125 3 DF2FGN125 0.160
NH 00 a 500 160 3 DF2FGN160 0.160
Blade a 690 50 3 DF2GN1051 0.230
NH 0 63 3 DF2GN1061 0.230
DB430663.eps

80 3 DF2GN1081 0.230
100 3 DF2GN1101 0.230
125 3 DF2GN1121 0.230
160 3 DF2GN1161 0.230
a 500 125 3 - -
DF4 GNpppp 160 3 - -
Blade a 690 160 1 DF2HN1161 0.400
NH 1 200 1 DF2HN1201 0.400
a 500 250 3 DF2HN1251 0.400
Blade a 690 250 3 DF2JN1251 0.560
NH 2 315 3 DF2JN1311 0.560
DB425719.eps

a 500 400 3 DF2JN1401 0.560


Blade a 690 500 3 - -
NH 3 a 500 500 1 DF2KN1501 0.850
630 1 DF2KN1631 0.850
[1] Set of 3.

DF2 JNpppp

D-17
Catalog numbers www.se.com

D-18
Schneider Electric Industries SAS

35, rue Joseph Monier


CS 30323
92506 Rueil Malmaison Cedex
France

RCS Nanterre 954 503 439


Capital social 928 298 512 €
www.se.com

10/2020
© 2020 - Schneider Electric. All Rights Reserved.
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Document reference: LVPED216031EN

You might also like