Distribution & Utilization

Download as pdf or txt
Download as pdf or txt
You are on page 1of 154

GOVERNMENT OF TAMILNADU

DIRECTORATE OF TECHNICAL EDUCATION


CHENNAI – 600 025
STATE PROJECT COORDINATION UNIT

Diploma in Electrical and Electronics Engineering


Course Code: 1030
M – Scheme

e-TEXTBOOK
on
Distribution and Utilisation
for
VI Semester DEEE
Convener for EEE Discipline:

Er.R.Anbukarasi ME.,
Principal,
Tamilnadu Polytechnic College,
Madurai, 625011.

Team Members for Distribution and utilisation

1. Mrs.V.Thenmozhi M.E.,
Sr.GradeLecturer/EEE
Tamilnad polytechnic college.
Madurai.
2. Mr.S.G.Kadhiravan M.TECH.,
Lecturer(S.G) /EEE
SeshasayeeInstitute of technology ,
Trichy.
3. Mrs.G.JeyalakshmiM.E,M.B.A.,
HOD/EEE
K.L.Nagaswamy memorial Polytechnic College,
Madurai, 625009.

Validated by

Dr. SARAVANAN.,
Associate Professor,
Department of Electrical and Electronics Engineering,
Thiagarajar College of Engineering, Madurai.

1
SYLLABUS

RATIONALE:

Distribution system is that part of power system which distributes power to the consumers for utilization. So
to have adequate knowledge in distribution and utilization of Electrical energy it becomes necessary to
include this subject.

OBJECTIVES:

To Understand

 Substation arrangements.

 Distribution -classification and scheme of connection.

 Drives-Suitability for different applications.

 Track Electrification-Traction mechanics.

 Traction motors and control.

 Illumination -Design of lighting scheme-sources of light.

 Electric Heating- Different methods.

 Electric furnaces and Temperature control.

 Electric welding and welding equipments.

2
DETAILLED SYALLABUS
CONTENTS

Unit Name of the Topics Hrs

I DISTRIBUTION (Pg.No. 5-36) 18

Substation: Introduction-Sub stations-classification of sub stations-Indoor and


outdoor S.S – Gas insulated S.S-comparisons-Layout 110/11KV Substation and
11KV/400V Distribution Substation-substation equipments-Bus bar- Types of bus
bar arrangement -Advantages and Disadvantages.

Distribution: Distribution system-Requirements of a Distribution system-part of


Distribution system- classification of Distribution systems-comparison of different
distribution systems (A.C and D.C) -A.C Distribution -Types-connection schemes of
Distribution system-A. C Distribution calculations-Calculation of voltage at load
points on single phase distribution systems (With concentrated load only)-
Distribution fed at one end, both ends and ring mains-problems- Three phase, four
wire, Star connected unbalanced load circuit- Problems- consequence of
Disconnection of Neutral in three phase four wire system (illustration with an
example)

II INDUSTRIAL DRIVES (Pg.No. 37-56) 15


Introduction-Electric drive- Advantages-parts of Electric drives- Transmission of
power-Types of Electric drives-Individual, group and multi motor drives –
Advantages and disadvantages of Individual and group drive -Factors governing the
selection of motors-Nature and classification of load Torque-Matching of speed
Torque characteristics of load and motor-Standard ratings of motor- classes of load
duty cycles-Selection of motors for different duty cycles-Selection of motors for
specific application-Braking- Features of good braking system- Types of Braking-
Advantages of- Electric braking-Plugging, Dynamic and Regenerative braking-As
applied to various motors.

III ELECTRIC TRACTION (Pg.No. 57-93) 16


Introduction-Traction systems-Advantages and Disadvantages of Electric Traction.
System of Track Electrification:
Methods of supplying power-Rail connected system and over head system-O.H.
equipments-contact wire, centenary and droppers-
current collection gear for OHE-Bow and pantograph collector-Different systems of
Track Electrification-Advantages of single phase low frequency A. C. system-
Booster Transformer-Necessity- Methods of connecting B.T-Neutral sectioning.
Traction Mechanics:Units and notations used in Traction mechanics-Speed time
curve for different services - simplified speed time curve-Derivation of maximum
speed-crest speed, Average speed, Schedule speed (definitions only)-Tractive effort
and power requirement- Specific energy output- specific energy consumption.
Traction motors and control:Desirable characteristics of Traction motors-Motors used
for Traction purpose-Methods of starting and speed control of D.C Traction motors-
Rheostatic Control-energy saving with plain rheostatic control series- parallel
control- Energy saving with series parallel starting - Shunt Transition -Bridge-
Transition- multiple unit control –Regenerative braking.Recent trends in Electric
Traction-Magnetic Levitation (MEGLEV) - Suspension systems.

3
IV ILLUMINATION (Pg.No. 94-120) 17

Introduction - Definition and units of different terms used in illumination-plane


Angle, Solids angle, Light, Luminous flux, Luminous Intensity, Luminous Efficacy
candle power, Lumen, Illumination,M.S.C.P, M.H.C.P, M.H.S.C.P- Reduction factor,
Luminance, glare Lamp efficiency. Space-height ratio, Depreciation factor
Utilization factor, waste light factor, Absorption factor, Beam factor, Reflection
factor- Requirements of good lighting system- Laws of Illumination-problems. Types
of lighting scheme- Factors to be considered while designing lighting scheme-
Design of lighting Scheme (Indoor and outdoor)- Problems- Lighting systems-
Factory lighting, Flood lighting, Street lighting.

Sources of light-Arc lamp, Incandescent lamp, Halogen Lamp, Sodium vapour lamp,
High pressure mercury vapour lamp, Fluorescent Tube –Induction Lamp- Energy
saving lamps (C.F.L and L.E.D lamps)-limitation and disposal of C.F.L-benefits of
led lamps-comparison of lumen output for led CFL and incandescent lamp.

V ELECTRIC HEATING AND WELDING (Pg.No. 121-154)

Electric Heating:Introduction -Advantages of Electric heating-modes of heat


transfer- classification of Electric Heating - Power frequency electric heating- Direct
and Indirect resistance heating-Infrared heating-Arc heating –High frequency Electric 16
heating- Induction heating-Induction Stove –Eddy current heating and Dielectric
heating.

Electric furnaces:Resistance furnace-Requirements of Heating elements-commonly


used heating element materials-Resistance furnace for special purposes-Temperature
control of resistance furnace-Arc furnace -Direct and Indirect Arc furnace-
Temperature control of Arc furnace-Reasons for employing low voltage and high
current supply - Induction furnace-Direct and Indirect core type Induction furnace-
coreless Induction furnace-Power supply for coreless Induction furnace.

Electric welding:Introduction-Types of Electric welding-Requirements of good


weld- Preparation of work -Resistance welding- Butt welding, Spot welding, Seam
welding, Projection welding and Flash welding-Arc welding-Carbon Arc welding,
metal Arc welding, Atomic hydrogen Arc welding, Inert gas metal arc welding-
Comparison between Resistance and Arc welding. Radiation welding - Ultrasonic
welding, Electron beam welding, LASER beam welding-Electric welding equipments
(A.C. and D.C).

TEXT BOOK:

1. A Course in Electrical Power by Soni&Gupta DhanpatRai& Sons, Delhi.

REFERENCE BOOKS:

1.Electric Power by SL UppalKhanna Publishers, NewDelhi

2. Modern Electric Traction by H PartabDhanpatRai& Sons, New Delhi

3.ElectricalPowerDistribution System by AS Pabla Tata McGraw Hill Publishing Co, New Delhi.

4.Utilization of Electric Power NV Suryanarayana Tata McGraw Hill Publishing Co, New Delhi.

4
UNIT I
DISTRIBUTION
SUBSTATIONS:
1.1 Introduction:
In all the regions the power flow of electrical energy takes place through Electrical Substations. An
electrical substation is an assemblage of electrical components including bus bars, switchgear, power
transformers and auxiliaries. The various substations located in generating stations, transmission systems,
and distribution systems and in the consumers premises have similar layouts and similar electrical
components.
1.2. Electrical Substations
Substations are integral parts of a power system and form important links between the generating stations,
transmission systems, distribution systems and the load points
Basically an electrical substation consists of a number of incoming circuits and outgoing circuits connected
to common busbar systems. Busbars are conducting bars to which a number of incoming or outgoing
circuits are connected. Each circuit has certain electrical components such as circuit breakers, isolators,
earthling switches, current transformers, voltage transformers.
A substation receives electrical power from generating station incoming transmission lines and delivers
electrical power the outgoing transmission lines.
Functions of a Substation
1.3. An electricity supply undertaking generally aims at the following:
 Supply of required electrical power to all the consumers continuously at all times.

 Maximum possible coverage of the supply network over the given geographical area

 Maximum security of supply

 Shortest possible fault-duration

 Optimum efficiency of plants and the network

 Supply of electrical power within targeted frequency limits (49.5Hz and 50.5Hz)

 Supply of electrical power within specified voltage limits

 Supply of electrical energy to the consumers at the lowest cost.


1.4.The tasks associated with major substations in the transmission and distribution system include
the following:
 Protection of transmission system

 Controlling the exchange of energy

 Ensuring steady state and transient stability

 Load shedding and prevention of loss of synchronism. Maintaining the system frequency
within targeted limits.

 Voltage control reducing the reactive power flow by compensation of reactive power tap-
changing

5
 Securing the supply by providing adequate line capacity and facility for changing the
transmission paths.

 Data transmission power line carrier for the purpose of network monitoring: control and
protection.

 Determining the energy transfer through transmission lines and tie lines

 Fault analysis and pin-pointing the cause and subsequent improvements

 Securing supply by feeding the network at various points.

 Establishing economic load distribution and several; associated functions.

These tasks are performed by the team work of load control centre control rooms of generating
stations and control room of substations. The substations perform several important tasks and are
integral parts of the power system.
1.5 .A typical substation has the following essential features:
 Outdoor switchyard having any one of the any bus bar schemes
 Low voltage switchgear, high voltage switchgear and control room building
 Office building
 Roads and rail track for transporting equipment
 Incoming line towers and outgoing line towers/cables
 Store
 Maintenance workshop
 Auxiliary power supply scheme
 protection system
 Battery room and low voltage dc supply system
 Fire fighting system
 Cooling water system Drinking water system
 Station earthing system
 Lighting protection system overhead shielding
 Drainage system
 Substation lighting system
 Fence and gates Security system

1.6. Types of Substations

The substations can be classified in several ways including the following:

1. Classification based on voltage levels


A.C.Substation: EHV, HV, MV, LV,: HVDC Substation

2. Classification on constructional features


Outdoor or Indoor
Outdoor substation is under open sky. Indoor substation is inside a building
3. Classification based on configuration
Conventional air insulated outdoor substation of SF6 Gas insulated substation (GIS)
Composite substation having combination of the above two.

6
4. Classification based on application
 Switchyard in generating station
 Switching substation
 Sending end substation
 Receiving end substation
 Distribution substation
 Factory substation
 Compensating substation
 Load substation eg: arc furnace substation

1.7.Comparison of indoor and outdoor S.S:

 Generally indoor equipment is preferred for voltages up to 33KV.for voltages of 33KV and above
outdoor switchgear is generally preferred.
 However in heavily polluted areas indoor equipment may be preferred even for higher voltages.
 Recently indoor metal clad SF6 insulated switchgear has been introduced for medium high voltages
such as 3.3KV, 6.6KV, 11KV, 33KV
 An outdoor equipment is installed under the open sky. The indoor switchgear is generally in the
form of metal enclosed factory assembled units called metal clad switchgear.
a)Advantages of outdoor S.S

 Simple
 Low initial cost.
 Less quantity of building materials
 Time required for erection is less.
 Fault identification is easier.
 Extension is easier.
 Accidental occurrences can be easily solved.

b) Disadvantages of outdoor S.S

1. More space required for erection.


2. Dust and dirt are deposited over the equipments.
3. The switching operations becomes difficult during raining seasons.
4. Cost of installation is more.

5. Maintenance cost is more.

1.8. GAS INSULATED S.S

The atmospheric air insulation used in a conventional, air-insulated substation (AIS) requires meters of air
insulation to do what SF6 can do in centimeters.

GIS can therefore be smaller than AIS by up to a factor of 10. A GIS is mostly used where space is
expensive or not available. In a GIS the active parts are protected from the deterioration from exposure to
atmospheric air, moisture, contamination, etc.SF6 gas insulated high voltage switchgear has been in
commercial operation for more than 30 years. GIS is more reliable and requires less maintenance than AIS

a) UNIQUE FEATURES:

The modular of design of GIS offers a high degree of flexibility to meet layout requirements of both
substations, as well as power station switchgear, making efficient use of available space. GIS technology
has reached a stage of application and a wide range of GIS equipment up to highest voltage of 800 kV is
available with many unique features. They are:

7
1. Wide spread application of aluminum enclosure materials for standardized component models for all
voltage ranges.

2. The light weight enclosures have good conductivity, low eddy-current losses and a high resistance to
corrosion.

3. Easy handling, as well as reduced stresses on foundation and support structure are additional features.

4. Standard arrangements can be easily modified and extended with good co-ordination between the
manufacturer and the user.

5. A gas- tight barrier insulator in switchgear serve for the separation of gas compartments and prevents
neighboring switchgear parts from being affected during maintenance.

b) A typical Gas insulated substation is shown in Fig.

The Gas insulated substation shown in above figure comprises the following components:

1. Circuit breaker2. Disconnectors switch3. Earthing switch

4. Current transformer 5. Voltage transformer6. Bus bar & connectors

7. Power transformer 8. Surge arrester9. Cable termination10. SF6 / air or SF6 / oil bushing

The GIS require less number of lightning arresters than a conventional one. This is mainly because of its
compactness. The basic consideration for insulation coordination is V-T characteristic. The V-I
characteristic of SF6 is considerably flat compared to that of air. Air can withstand to very high voltages for
very short time. However, as the duration of voltage increases, the withstand voltage falls off considerably.
On the other hand, SF6 exhibits a flat characteristic, thus the ratio of basic lightning impulse level is close to
unity for GIS, whereas for the

Conventional substations this ratio varies between 0.6 and 0.86.

8
c) Advantages of GIS over the conventional open air substation:

The application of GIS during the last fifteen years has been very rapid. The rapid growth in GIS
application is due to the following special advantages:

1. Area and volume saving in construction for over or underground applications. Therefore they offer saving
in land area and construction costs.

2. Insensitivity to external influences because of grounded metal enclosures.

3. Greatly improved safety and reliability due to earthed metal housing of all high voltage parts and much
higher intrinsic strength of SF6 gas as insulation.

4. Short on site erection times, based on large factory assembled and tested shipping units

5. Fulfillment of aesthetic requirements with indoor applications

6. High service reliability due to non-exposure of the use of high voltage parts to atmosphere influences

7. Reduction in radio interference with the use of earthed metal enclosures

8. Use as mobile substations for transportation to load centers on standard tracks. These substations can be
located closer to load centers thereby reducing transmission losses and expenditure in the distribution
network.

9. More optimal life cycle costs because of lesser maintenance, downtime and repair costs.

10. It is not necessary that high voltage or extra high voltage switchgear has to be installed outdoors.

d) Disadvantages of GIS:

Although GIS has been in operation for several years, a lot of problems encountered in practice need fuller
understanding. Some of the problems being studied are:

1. Switching operation generate Very Fast Transients Over Voltages (VFTOS).

2. VFTOS may cause secondary breakdown inside a GIS and Transient Enclosure Voltages (TEV) outside
the GIS.

3. Field non-uniformities reduce withstanding levels of a GIS.

4. Prolonged arcing may produce corrosive/toxic by-products.

9
1.9. LAYOUT OF 110 /11KV SUBSTATION Fig.1.2

1.10. LAYOUT OF 11KV /400V DISTRIBUTION SUBSTATION

The conductor system by means of which electric power is conveyed from a generating station to the
consumer’s premises may, in general, be divided into two distinct parts i.e. transmission system and
distribution system. Each part can again be sub-divided into two—primary transmission and secondary
transmission and similarly, primary distribution and secondary distribution and then finally the system of
supply to individual consumers. A typical layout of a generating, transmission and distribution network of a
large system would be made up of elements as shown by a single-line diagram in Fig.

Now-a-days, generation and transmission is almost exclusively three-phase. The secondary trans-
mission is also 3-phase whereas the distribution to the ultimate customer may be 3-phase or single-phase
depending upon the requirements of the customers.

In Fig., C.S. represents the central station where power is generated by 3-phase alternators at 6.6 or 11
or 13.2 or even 33 kV. The voltage is then stepped up by suitable 3-phase transformers for transmission
purposes. Taking the generated voltage as 11 kV, the 3-phase transformers step it up to 132 kV as shown.
Primary or high-voltage transmission is carried out at 132 kV.

10
The 3-phase, 3-wire overhead high-voltage transmission line next terminates in step-down trans-formers
in a sub-station known as Receiving Station (R.S.) which usually lies at the outskirts of a city because it is
not safe to bring high-voltage overhead transmission lines into thickly-populated areas. Here, the voltage is
stepped down to 33 kV.

From the Receiving Station, power is next transmitted at 33 kV by underground cables or by overhead
lines to various sub-stations (S S) located at various strategic points in the city. This is known as secondary
or low-voltage transmission. From now onwards starts the primary and secondary distribution.

At the sub-station (S S) voltage is reduced from 33kV to 3.3kV 3-wire for primary distribution.
Consumers whose demands exceed 50 kVA are usually supplied from SS by special 3.3 kV feeders. The
secondary distribution is done at 400/230 V for which purpose voltage is reduced from 3 .3kV to 400 V at
the distribution sub-stations. Feeders radiating from distribution sub-station supply power to distribution
networks in their respective areas. The most common system for secondary distribution is 400/230-V, 3-
phase 4-wire system. The single-phase residential lighting load is connected between any one line and the
neutral

Fig.1.3.LAYOUT OF 11KV /400V DISTRIBUTION SUBSTATION

1.11. SUBSTATION EQUIPMENTS:

A sub-station is an assemblage of electrical apparatus. These include Busbars, Circuit breakers,


Isolator with ear thing switch, insulator ,Surge arresters ,CTs ,PTs, Line trap unit coupling
capacitors, compensation equipments, power transformers ….

11
1. Transformers:

Transformers are necessary in a substation for stepping – up and stepping down of ac voltage besides the
transformers the substation has several others electrical equipments including busbars circuit breakers
isolators surge arresters CTs, VTs, shunt Reactors and Shunt Capacitors.

2. Circuit-breakers

A device capable of making and breaking an electric circuit under normal and abnormal conditions such as
short circuits. It can operate automatically and clear fault currents safely and quickly.

Circuit-breakers are the switching and current interrupting devices. Basically a circuit breaker comprises of
fixed and movable contacts. The contacts can be separated by means of an operating mechanism. The
separation of current carrying contacts produces an arc. The arc is extinguished by a suitable medium such
as dielectric oil, vaccum,SF6gas. The circuit-breakers are necessary at every switching point in the
substation.

3. Isolators:

A switching device which can be opened or closed only under no current condition. It provide isolation of a
circuit for the purpose of maintenance

Isolators are disconnecting switches which can be used for disconnecting circuitbreakers. An isolator can be
opened after the circuit breaker. After opening the isolator the Earthing switch can be closed to discharge
the trapped electrical charges to the ground.

4. Current Transformers and potential transformers:

The current transformers and voltage transformers are used for transforming the current and voltage to a
lower value for the purpose of measurement, protection and control.

a) Current Transformer (CT):

The current ratio of current transformers is generally high (500A/5A) and volt ampere capacity is relatively
low (50 VA) as compared with that of the power transformers.

b) Voltage Transformer (PT):

The volt-ampere capacity of a potential transformer is low(100VA) and the voltage ratio is relatively high
(132kv/100v).The protective relays are connected in the secondary circuits of CTs and PTs.

5. Busbar:

Busbars are conductors to which several circuits are connected Busbar are either flexible or rigid.
Flexiblebus bars are made of ACSR conductors and are supported on strain insulators. Rigidbus bars are
made up of aluminum tubes and are supported on post insulators.

6. Earthing Switch.

It is a switch which connects a conductor to the earth so as to discharge the charges on the conductor to the
earth. Earthing switches are generally installed on the frames of the isolators.

7. Relay

12
It is an automatic device, which closes its contacts when the actuating quantity/quantities reach a certain
predetermined magnitude/phase.

8. Lighting Arrester (Surge Arrester)

The equipment connected between the conductor and ground to discharge the excessive voltages to earth.

Surge arresters divert the over-voltages to earth and protect the substation equipment from over voltage
surges.

9. Auto-reclosures:

Automatic closing of the circuit breaker after its opening. Autoreclosure is provided to restore the service
continuity after interrupting transient fault. High voltage circuit breakers used for controlling overhead
transmission lines and distance protection scheme for line protection are provided with such a feature

10. HRC Fuse

High rupturing capacity cartridge fuse is used for over current protection of low voltage and high voltage
circuit.

11. Protective Scheme

A selected set of protective systems which protect one or two components of the power systems against
abnormal conditions:

Eg: generator protection scheme transformer protection scheme

12. Structure:

Galvanized steel structures are made of bolted/welded structures of angles/channels/pipes. These are used
for towers gantries equipment support structures. Galvanised structures provide rigid support to the various
equipment and insulators. The design should be safe and economical.

Compensating substations are installed at an interval of 300km along EHV – AC lines for feeding reactive
power VAR to line

13. Following compensation Equipment is necessary for voltage control:

a) Series capacitors are sometimes installed in series with long EHV AC Transmission lines to compensate
line reactance.

b) Shunt capacitors are installed near load points in distribution substations receiving substations for
improvement of power factor. Shunt capacitors are switched on during high inductive loads. They are
switched off during low loads. Shunt capacitors are also included in static VAr sources (SVS).

c) Shunt Reactor are necessary with long EHV transmission lines to compensate the reactive power of the
line capacitance during low loads.

d) StaticVAr Sources (SVS).These are thyristor controlled shunt capacitors and shunt reactors which give
rapid, stepless control of reactive power VAR. These are connected in receiving stations and distribution
systems.

e) Power Line Carrier Current Equipment (PLCC) is necessary for transmitting / receiving high frequency
signals over the power line (transmission line) for the following:

13
Voice communication, Data transmission, Protection signaling, Control signaling

1.12. Functions of substation equipments:

Equipment Function

1. Busbar Incoming and outgoing circuits connected


busbars

2. Circuit-breakers Automatic switching during normal or abnormal


conditions

3. Isolators ( Disconnections) Disconnection under no-load condition for safety


isolation and maintenance

4. Earthing switch To discharge the voltage on dead lines to earth

5. Current Transformer To step-down currents for measurement control


and protection

6. Voltage Transformer To step down currents for measurement control


and protection

7. Lighting Arrester (surge arrester) To discharge lightning over voltages an


switching over voltages to earth

8. Shunt Reactor To provide reactive power compensation during


low loads

9. Series Reactors To reduce the short circuit current or starting


currents

10. Neutral-Grounding Resistor To limit the earth fault current

11. Coupling capacitor To provide connection between high voltage line


and power line carrier current equipment

12. Line trap To prevent high frequency signals from entering


other zones

13. Shunt capacitors To provide compensations to reactive loads of


lagging power factors

14. Power Transformer To step-up or step-down the voltage and transfer


power from one ac voltage to another ac voltage
at the same frequency

15. Series Capacitors Compensation of long lines

1.13. A substation is composed of the following distinct circuit:

1. Main circuits through which the power flows from incoming lines to the outgoing lines to the
outgoing lines. These circuits are generally at high voltage AC and transfer the bulk power. Three
phase AC circuits are used. Each phase is insulated from the other (except at neutral points) and
from the earth

14
2. AC control and protection circuits connected to the secondary of CTs and VTs these circuits are at
low voltage AC Protective relays and control equipment are connected in these circuits. Low
voltage ac and dc circuits for metering protection and control communication
3. Auxiliary AC and DC power circuits carrying high power at high voltage. These are through
underground cables

1.14. Bus bars

 Bus bars are conductors to which several circuits are connected .Bus bar are either flexible or rigid.
Flexible bus bars are made of ACSR conductors and are supported on strain insulators. Rigid bus
bars are made up of aluminum tubes and are supported on post insulators.

 Bus bars are either in the form of aluminum tubes of ACSR conductors Aluminum tubular bus bars
are mounted on post insulators. ACSR bus bars are flexible and are supported on strain insulators.
Bus bars are in two or three horizontal planes.

 The incoming circuits and outgoing circuits are connected to the bus bars the bus bars carry the
main power and should be reliable.

a) The main functional requirements of bus bars system is:


 To carry normal currents and over load currents continuously with temperature rise within
specified limits.

 To with stand normal system voltage specified transient over voltage without flashover

 To withstand mechanical stresses due to wind icing short circuits without damage

 To provide low resistance path for current flow.

 To provide flexibility of operation

 Simplicity, safety, Aesthetic looks, Quality Reliability

 Maintenance Requirements

b) Types of Bus bar Systems (Bus bar Layouts)

1. Single bus bar system


2. Single sectionalized bus bar system
3. Duplicate bus bar system with one breaker per circuit
4. Duplicate bus bar system with two breakers per circuit
5. Main and transfer bus bar
6. Ring bus bar
7. Breaker and a half bus bar system
8. Mesh bus bar scheme
9. Hybrid system

15
1. Single Bus bar scheme.

The single bus bar scheme has only one three phase bus to which the various incoming and outgoing circuits
are connected

Single bus bar scheme is not preferred for major substations

In the event of a bus fault a breaker failure the entire bus has to be de energized and a major outage occurs.
Dependence on only one main bus gives lack of operational flexibility

For maintenance of the main bus or while providing extension to the main bus the entire station shall be de
energized

Although the protective relaying is relatively simple it lacks flexibility and during a bus fault the entire bus
is switched off resulting in a major outage

Fig 1.4.Single bus bar scheme is used for DC switchboards and very small AC Substations or generating
stations. They are used for low voltage medium voltage bus bars up to 33kv in the form of open outdoors
switch yard of indoor metal clad switchgear

2. Single Sectionalized Bus bar

In a sectional bus bar the main bus is divided into two of more sections with a circuit breaker and isolators
in between the adjoining sections. One section can be completely shut down for the purpose of bus
maintenance repairs of extension without disturbing without disturbing the continuity of the other bus
section

16
In Fig 1.5.Single Sectionalized Bus bar the number of sections depends up to the importance of the station and
local switching requirements.

The fault level of each bus can be reduced by installing a current limiting reactor in between the two
adjoining sections

When two parallel feeders are taken from the same bus to one load point they are connected to different bus
sections so that even if one feeder is dead during maintenance of one bus section the other feeder continue
to serve.

Bus sectionalizing should be through a circuit breaker so that the bus transfer can be carried out under full
load conditions.

Two isolators should be provided with each sectionalizing circuit breaker to enable the maintenance of the
circuit breaker.

If only isolator is used a sectionalizing switch the opening and closing of the same should be under no load
condition.

In case each section is supplied from a different source there should be a provision of synchronizing the two
bus sections. Before closing the circuit breaker the conditions for synchronism shall be satisfied.

3. Double Bus bar Scheme

Duplicate Bus bar Scheme is used universally for important EHV substations (110kv and above). The
duplicate bus bar scheme is costlier than the single bus bar scheme is costlier than the single bus bar scheme
but it gives higher operational flexibility and permits bus bar maintenance repairs or extension without
shutdown.

17
In Fig 1.6.Double Busbar Scheme These schemes have two three phase bus bars called main bus and
reserve bus or bus no 1 and bus no 2. The main bus is for normal us and the reserve bus is available in case
of maintenance or fault on the main bus.

The Reserve Bus can also be used for testing a new feeder charging a feeder at higher voltage for test
purposes for commissioning tests on a new plant. All these activities can be carried out without disturbing
the main bus.

During normal service only one of the buses is energized the other bus is in reserve. If both the buses are to
be simultaneously in service the protective relaying becomes complex.

The connection between each incoming and outgoing circuits and the duplicate bus is through either one
circuit breaker or two bus selecting isolators one for each bus bar through two circuit breakers and two
insulators one circuit breaker one isolator for each bus bar.

3. Sectionalized Double Bus bar Scheme Fig 1.7

18
In this scheme the auxiliary bus bars are used with the sectionalized main bus bar. In this method, any
section of the bus bar can be isolated for maintenance work. The auxiliary bus is not sectionalized because
of avoiding un necessary expenses.

4. Ring Bus (Mesh Scheme) In the ring bus scheme the busbars and the breakers are in series to form a
ring. The circuits are connected between the breakers. The number of breakers is equal to the number of
circuits. During the normal operation all the circuit breakers are closed. During a circuit fault two breakers
in the associated bus bar are tripped. If one of these breakers fails to clear the fault an additional circuit will
be tripped by breaker stuck up back up relay. During the breaker maintenance the faint is opened but all the
circuits continue to serve.

In the ring scheme sources and circuits are connected alternately. During breaker maintenance no change in
protective relay is required.

The ring bus is economical in cost as it requires only one breaker per circuit. Ring bus has good reliability
good flexibility and is safe to operate.

In fig 1.8. The Ring bus is considered to be suitable for important 220kv and 400kv substations having up to
five circuits. For more than five circuits breaker and half scheme is preferred

Ring bus gives a better security than simple single bus because alternative route is available around the bus
to the outgoing circuit.

In case of bus bar fault the immediate result is similar to that of single bus bar scheme that all circuits are
lost. However the fault can be isolated by opening the bus bar isolators on either sides or most of the circuit
can be reenergized

Mesh scheme is called Ring Scheme in USA and Mesh scheme in England. In mesh scheme the bus forms a
ring and circuit breakers are in the closed ring instead of bing in outgoing or incoming circuits

Ring bus has low cost. It is flexible for breaker maintenance

19
1.15. Distribution system

That part of power system which distributes electric power for local use is known as distribution system. In
general the distribution system is the electrical system between the substation fed by the transmission
system and the consumer’s meters. It generally consists of feeder’s distributors and the service mains. The
single line diagram of a typical low tension distribution system is Fig 1.9

Feeders

A feeder is a conductor which connects the substation or localized generating station to the area where
power is to be distributed, Generally no tapping’s are taken from the feeder so that current in it remains the
same throughout. The main consideration in the design of a feeder is the current carrying capacity

Distributor

A distributor is a conductor from which tapping’s are taken for supply to the consumers. In BC CD and DA
are the distributors. The current through a distributor is not constant because tappings are taken at various
places along its length. While designing a distributor voltage drop along its length is the main consideration
since the statutory limit of voltage variations is 5% of rated value at the consumer’s terminals

Service mains

A service mains is generally a small cable which connects the distributor to the consumer terminals.

1.16. Classification of Distribution Systems

1. A distribution system may be classified according to Nature of current:

i) d.c. distribution system ii)a.c. distribution system

Now a days ac system is universally adopted for distribution of electric power as it is simpler and more
economical than direct current method

2. Type of construction

According to type of construction distribution system can be classified as

i) Overhead system

ii) Underground system.

20
The overhead system is generally employed for distribution as it is 5 to 10 times cheaper than the equivalent
underground system. In general the underground system is used at places where overhead construction is
impracticable or prohibited by the local laws

3. Scheme of connection

According to scheme of connection the distribution system may be classified as:

i) Radial system

ii) Ring main system

iii) Interconnected system.

1.17. AC Distribution

Now a day’s electrical energy is generated transmitted and distributed in the form of alternating current.
One important reason for the widespread use of alternating current in preference to direct current is the fact
that alternating voltage can be conveniently changed in magnitude by means of a transformer. Transformer
has made it possible to transmit ac power at high voltage and utilize it at a safe potential. High transmission
and distribution voltages have greatly reduced the current in the conductors and the resulting line losses

There is no definite line between transmission and distribution according to voltage or bulk capacity.
However in general the ac distribution system is the electrical system between the step down substation fed
by the transmission system and the consumer’s meters. The ac distribution system is classified into primary
distribution system and secondary distribution system.

a) Primary distribution system

It is that part of ac distribution system which operates at voltages somewhat higher than general utilization
and handles large blocks of electrical energy than the average low voltage consumer uses. The voltage used
for primary distribution depends upon the amount of power to be conveyed and the distance of the
substation required to be fed. The most commonly used primary distribution voltages are 11KV 6.6KV and
3.3KV Due to economic considerations primary distribution is carried out by 3 phase 3 wire system

Electric power from the generating station is transmitted at high voltage to the substation located in or near
the city. At this substation voltage is stepped down to 11kv with he help of step down transformer. Power is
supplied to various sub stations for distribution or to big consumers at this voltage. This forms the high
voltage distribution or primary distribution

b) Secondary distribution system

It is that part of ac distribution system which includes the range of voltages at which the ultimate consumer
utilizes the electrical energy delivered to him. The secondary distribution employs 400/230v 3 phase 4 wire
system

The primary distribution circuit delivers power to various substations called distribution substations. The
substations are situated near the consumers localities and contain step down transformers at each
distribution substation the voltage is stepped down to 400v and power is delivered by 3 phase 4 wire ac
system. The voltage between any two phases in 400v and between any phase and neutral is 230v.The single
phase domestic loads are connected between any one phase and the neutral whereas 3 phase 400v motor
loads are connected across 3 phase lines directly

21
1.18. DC Distribution

It is a common knowledge that electric power is almost exclusively generated transmitted and distributed as
ac however for certain applications dc supply is absolutely necessary. For instance dc supply is required for
the operation of variable speed machinery for electro chemical work and for congested areas where storage
battery reserves are necessary. For this purpose ac power is converted into dc power at the substation by
using converting machinery static rectifier, mercury arc rectifiers’ rotary converters and motor generator
sets. The dc supply from the substation may be obtained in the form of 2 wire 3 wire for distribution

2 wire dc system as the name implies this system of distribution consists of two wires. One is the outgoing
or positive wire and the other is the return or negative wire. The loads such as lamps motors are connected
in parallel between the two wires as shown in fig. This system is never used for transmission purposes due
to low efficiency but may be employed for distribution of dc power

3 wire dc system

It consists of two outers and a middle or neutral wire which is earthed at the substation. The voltage
between the outers is twice the voltage between either outer and neutral wire as shown in fig the principal
advantage of this system is that it makes available two voltages at the consumer terminals V between any
outer and the neutral and 2v between the outers. Loads requiring high voltage are connected across the
outers whereas lamps and heating circuits requiring less voltage are connected between either outer and the
neutral the methods of obtaining 3 wire system are discussed in the following article

1.19. Connection schemes of Distribution system

All distribution of electrical energy is done by constant voltage system in practice the following distribution
circuits are generally used

a) Radial system

In this system separate feeders radiate from a single substation and feed the distributors at one end only. A
single line diagram of a radial system for dc distribution where a feeder OC supplies a distributor AB at
point A. Obviously the distributor is fed at one end only point A in this case show a single line diagram of

22
In Fig 1.10.Radial system for ac distribution the radial system is employed only when power is generated at
low voltage and the substation is located at the center of the load

This is the simplest distribution circuit and has the lowest initial cost. However it suffers from the following
draw backs

The end of the distributor nearest to the feeding point will be heavily loaded

The consumers are dependent on a single feeder and single distributor. Therefore any fault on the feeder or
distributor cutoff supply to the consumers, who are on the side of the fault away from the substation.

The consumers at the distant end of the distributor would be subjected to serious voltage fluctuations, when
the load on the distributor changes.

b) Ring main system (Fig.1.11)

In this system the primaries of distribution transformers form a loop. The loop circuit starts from the
substation bus bars makes a loop through the area to be served and returns to the substation shown the
single line diagram of ring main system for ac distribution, where substation supplied to the closed feeder
LMNOPQRS. The distributors are tapped from different points MOQ of the feeder through distribution
transformers. The ring main system has the following advantages

There are less voltage fluctuations at consumers’ terminals.

23
The system is very reliable as each distributor is fed two feeders. In the event of fault on any section of the
feeder. The continuity of supply is maintained for examples suppose that fault occurs at any point F of
section SLM of the feeder. Then section SLM of the feeder can be isolated for repairs and at the same time
continuity of supply is maintained to all the consumers’ feeders SRQPONM

c) Interconnected system Fig (1.12)

When the feeder ring is energized by two or more than two generating stations or substations it is called
inter connected system. Shows the single line diagram of interconnected system, where the closed feeder
ring ABCD is supplied by two sub stations S1 and S2 at points D and Q respectively. Distributors are
connected to points OPQ and R of the feeder ring through distribution transformers.

The interconnected system has the following advantages.

 It increases the service reliability


 Any area fed from one generating station during peak load hours can be fed from the other
generating station. This reduces reserve power capacity and increases efficiency of the system.
 Requirements of a distribution system.
 A good distribution system should ensure that the voltage variations at consumers terminals are
within permissible limits
 Availability of power demand.
 Power must be available to the consumers in any amount that they may require from time to time.
 Reliability.

1.20. Systems of A.C. Distribution

A.C. power transmission is always at high voltage and mostly by 3-phase system. The use of single-
phase system is limited to single-phase electric railways. Single-phase power transmission is used only for
short distances and for relatively low voltages. 3-phase power transmission requires less copper than either

24
single-phase or 2-phase power transmission.

With respect to phases, the following systems are available for the distribution of a.c. power.

1. Single-phase, 2-wire system.


2. Single-phase, 3-wire system.
3. Two-phase, 3-wire system.
4. Two-phase, 4-wire system.
5. Three-phase, 3-wire system.
6. Three-phase, 4-wire system.
1.21. A.C distribution calculations

Methods of solving AC Distribution Problems:

In a.c distribution calculations, power factors of various load currents have to be considered, since currents
in different sections of the distributor will be the vector sum of load currents and not the arithmetic sum.
The power factors of load currents may be given i) w.r.t. to receiving or sending end voltage ii) w.r.t to load
voltage itself.

i) Power factors referred to receiving end voltage:

Consider an ac distributor AB with concentrated loads of I1 and I2 tapped off at points C and B as shown in
fig. Taking the receiving end voltage VB as the reference vector, let lagging power factors at C and B cos1
and cos2 w.r.t.VB.

Let R1,X1 and R2,X2 be the resistance and reactance of section AC and CB of the distributor

Fig 1.13 Power factors referred to receiving end voltage

25
Impedance of section AC

=R1+jX1

Impedance of section CB

=R2+jX2

Load current at point C

I1=I1(cos1 -jsin1 )

Load current at point B

I2=I2(cos-jsin2)

Current in section CB

ICB=I2= I2(cos2 -jsin2)

Current in section AC

IAC=I1+I2

IAC= I1(cos1-jsin1)+ I2(cos2-jsin2 )

Voltage drop in section CB

VCB=ICBZCB= I2(cos2-jsin2) (R2 +jX2)

Voltage drop in section AC

= =[ I1 (cos1-jsin1 )+ I2 (cos2-jsin2 )]( R1+jX1)

Sending end voltage

Sending end current

= +

The vector diagram of the ac distributor under these conditions is shown in fig. Here the receiving end
voltage VB is taken as the reference vector. As power factors of loads are given w.r.t. VB therefore I1 and I2
lag behind VB by 1 and 2 respectively.

26
ii) Power factors referred to respective load voltages:

Fig 1.14. Power factors referred to respective load voltages

Suppose the power factor of loads in the previous are referred to their respective load voltages.then1 is the
phase angle between VC and I1 and 2 is the phase angle between VB and I2 .The vector diagram under these
conditions is shown

Voltage drop in section CB = 2 CB = I2 (cosφ2 - jsinφ2 ) (R2+jX2)

Voltage at point C= B + Drop in section CB

=VC└α

I1=I1 - φ1w.r.t voltage VC

I1 = I1 -( φ1- α) w.r.t voltage VB

I1=I1 [cos(φ1 - α-jsin(φ1- α)]

IAC=I1+I2

=I1 [cos(φ1- α)- jsin (φ1- α)] + I2(cos φ2-jsin φ2)

27
Voltage drop in section in AC = IAC ZAC

Voltage at point A= VB + Drop in CB + Drop in AC

Problem 1.A single phase ac distributor AB 300 meters long is fed from end A and is loaded as under

i) 100 A at 0.707 pf lagging 200m from point A

ii)200A at 0.8 pf lagging 300m from point A

The total resistance and reactance of the distributor is 0,2 Ω and 0.1Ω per kilometer. Calculate the total
voltage drop in the distributor. The load power refer to the voltage at the far end

Solution A 200 m C 100 m B

The single line diagram of the distributor

Impedance of distributor/km=(0.2+j0.1)Ω I1=100A I2=


200A

cos φ1 =0.707lag. cos φ2 = 0.8 lag

Impedance of section AC

AC=(0.2+J0.1)X200/1000=(0.04+j0.02)Ω

Impedance of section CB

CB=(0.2+j0.1)X100/1000=(0.02+j0.01)Ω

Taking voltage at the far end B as the reference vector we have

Load current at point B

2=I2(cos φ2-jsin φ2)=200(0.8-j0.6)

Load current at point C

1=I1(cos φ1-jsin φ1)=100(0.707-j0.707)=(70.7-j70.7)A

Current in section CB

CB= 2=(160-j120)A

Current in section AC

AC= 1+ 2=(70.7-j70.7)+(160-j120)=(230.7-j190.7)A

Voltage drop in section CB

CB= CB CB=(160-j120)(0.02+j0.01)=(4.4-j0.8)volts

Voltage drop in section AC

28
AC= AC AC=(230.7-j190.7)(0.04+j0.02)=(13.04-j3.01)volts

Voltage drop in the distributor

= AC+ CB=(13.04-j3.01)+(4.4-j0.8)=(17.44-j3.81)volts

Magnitude of drop

= =17.85V

Problem2.A single phase distributor 2 kilometers long supplies a load of 120 A at 0.8pf lagging at its far
end and a load of 80A at 0.9 pf lagging at its mid-point. Both power factors are referred to the voltage at the
far end. The resistance and reactance per km (go and return) are 0.05Ω and 0.1Ω respectively. If the voltage
at the far end is maintained at 230V.calculate

i)Voltage at the sending end

ii) Phase angle between voltage at the two ends

Solution:

A 1000m C 1000m B

The distributor AB with C as the mid – point

Impedance of distributor/km=(0.05+j0.1)Ω

I1
I2

Impedance of section AC

AC=(0.05+j0.1)X1000/1000=(0.05+j0.1)Ω

Impedance of section CB

CB=(0.05+j0.1)X1000/1000=(0.05+j0.1)Ω

Let the voltage VB at point B be taken as the reference vector

B=230+j0

i)Load current at point B:

2=120(0.8-j0.6)=96-j72

Load current at point C

1=80(0.9-j0.436)=72-j34.88

Current in section CB

29
CB=I2=96-j72

AC= 1+ 2=(72-j34.88)+(96-j72)=(168-j106.88)

Drop in section CB

CB= CB CB=(96-j72)(0.05+j0.1)=12+j0.6

Drop in section AC

AC= AC AC=(168-j106.88)(0.05+j0.1)=19.08+j11.45

Sending end voltage

A= B+ CB+ AC=(230+j0)+(12+j6)+(19.08+j11.45)=261.08+j17.45

Its Magnitude is

=261.67V

The Phase difference θ between VA and VB is given by

=0.0668

θ= = 3°49’

Problem3.A single phase distributor one km long has resistance and reactance per conductor of 0.1Ω and
0.15Ω respectively. At the far end the voltage VB=200V and the current is 100A at a pf of 0.8 lagging. At the
midpoint M of the distributor a current of 100A is tapped at a pf 0.6 lagging with reference to the voltage
Vm at the midpoint calculate

i)Voltage at mid point

ii)Sending end voltage VA

iii) Phase angle between VA and VB

Solution:

Fig Shown the single line diagram of the distributor AB with M as the mid point

Total impedance of distributor=2(0.1+j0.15)=(0.2+j0.3)Ω

Impedance of section AM

AM=(0.1+j0.15)Ω

Impedance of section MB

MB=(0.1+j0.15)Ω

30
Let the voltage VB at point B be taken as the reference vector

Then B=200+j0

i)Load current at point B A 500m M 500m B

2=100(0.8-j0.6)=80-j60

Current in section MB I1 I2

MB=I2=80-j60

Drop in section MB

VMB=IMB ZMB=(80-j60)(0.1+j0.15)=17+j6

Voltage at point M

VM=VB+VMB=(200+j0)+(17+j6)=217+j6

Its magnitude is = = 217.1V

ii)Phase angle between VM and VB

α= =1°35’

ii)The load current I1 has a lagging p.f of 0.6 VM.It lags behind VM by an angle φ1= =53°7’

Phase angle between I1 and VB


Φ’1=φ1-α=53°7’-1°35’=51°32’

Load current at M
=I1(cosφ’1-jsinφ’1) = 100(cos51°32’- jsin51°32’) = 62.2- j78.3

Current in section AM
IAM= 1+ 2=(62.2-j78.3)+(80-j60)=142.2-j138.3

Drop in section AM
AM= AM AM=(142.2+j138.3)(0.1+j0.15)=34.96+j7.5

Sending end voltage


A= M+ AM=(217+j6)+(34.96+j7.5)=251.96+j13.5

Its magnitude is
= =252.32V

iii) The phase difference θ between VA and VB is given by


tanθ =13.5/251.96=0.05358

31
θ= =3°4’

Hence supply voltage is 252.32V and leads VB by 3°4’

Problem 4. A single phase ring distributor ABC is fed at A. The loads at B and C are 20A at 0.8p.f lagging
and 15A at 0.6 p.f lagging respectively both expressed with reference to the voltage at A. The total
impedance of the three sections AB, BC and CA are (1+j1),(1+j2) and (1+j3) ohms respectively. Find the
total current fed at A and the current in each section.

Solution

Shows the ring distributor ABC. Thevenins theorem will be used to solve this problem. To find the current
in section BC, imagine that the section BC is removed as shown. The Thevenins equivalent circuit is shown

Current in section AB = 20 (0.8 – j0.6) = (16 – j12) A

Current in section AC = 15 (0.6 – j0.8) = (9 – j12) A

Voltage drop in section AB=IAB ZAB = (16-j12) (1+j1) = (28+j4) V

Voltage drop in section AC=IAC ZAC = (9-j12) (1+j3) = (45+j15) V

Voltage between BC = (45+j15)-(28+j4) = (17+j11) V

Thevenins equivalent circuit e.m.f. or open circuit voltage

Vo= (17+j11)V

Thevenins looking back impedance = ZT

ZT = ZAB+ZAC = (1+j1)+(1+j3) = (2+j4)Ω

Current is section BC = = = 2.60-j1.534 = 3.02

Since the voltage drop in section AC is high compared to VAB the potential at B is higher than C.
Hence current flows from B to C

Actual current in section AB ( AB) = 1+ BC-------(I1 and IBC current away from the junction B)

Actual current in section AB = (16-j12) + (2.60-j1.534) = (18.60-j13.534) = 23 -36.04

Actual current in section AC ( AC) = 2- BC

(I2 away from the junction C IBC towards the junction C)

Actual current in section AC = (9-j12) -(2.60-j1.534) = (6.4-j10.466) =12.27 -58.55

Current fed at A = (16-j12) + (9-j12) = (25-j24) = 34.65 -43.83° A

1.22- THREE PHASE, 4-WIRE STAR CONNECTED UNBALANCED LOAD CIRCUITS

In 3-phase 4-wire star-connected load circuits the star points of load and the generator are tied together
through neutral wire of zero impedance. Therefore the neutrals are at the same potential and voltage across
each impedance is same and equal to phase voltage whether the circuit is balanced or unbalanced. The three

32
phase currents or line currents can be determined by dividing the phase voltage by the impedance of the
concerned phase.

IR=VR/ZR ; IY=VY/ZY ; IB=VB/ZB

Fig 1.15. Three phase, 4-wire star connected unbalanced load circuits

The current in neutral wire can be determined by applying Kirchhoff’s first law at star point N. in Fig 1.15

According to which IR+IY+IB+IN=0 or current in neutral wire IN=-( IR+IY+IB)

In balanced load circuits the line currents are equal and have the same phase angles with their respective
phase voltages so their vector sum is zero and current in neutral wire is zero. In unbalanced load circuits the
neutral wire Carries currents.

Problem 5.In a 3-phase 4-wire system the line voltage is 400 volts and non inductive loads of 10, 8 and
5KW are connected between the three line conductors and the neutral .Calculate the current in each line and
the current in the neutral conductor

Solution:

Phase voltage across each load,

Rp = = = 231 V.

Current in R phase,

IR = = =43.4 A

Current in Y phase,

IY = = =34.7 A

Current in B phase,

IB = = =21.7 A

33
These currents are mutually 120 out of phase as the circuit is purely resistive. Taking IR as reference
vector, line current may be given as

I R = 43.4 (1+ j0)

I Y = 34.7 (-0.5- j0.866)

I B = 21.7 (-0.5+ j0.866)

b) Current in neutral wire,

IN = - ( IR + I Y+ I B)

= - [43.4 (1+ j0)+ 34.7 (-0.5- j0.866)+ 21.7 (-0.5+ j0.866)]

= -15.2 + j 11.258

IN = + = 18.9A

Φ = tan-1 = 143.5 A

1.23. Consequence of disconnection of neutral in three phase four wire system

In a balanced three phased four wire system when the neutral is disconnected no change is produced but in
case of unbalanced 3-phase 4-wire system when the neutral is disconnected the loads which are connected
between any two conductors and the neutral are connected in series and potential difference across the
combined load becomes equal to line voltage. The potential difference across each load is thus changed as
per rating of the load. The effect of disconnecting the neutral in a 3- phase 4- wire unbalanced system will
be clear from the following solved example.

Problem .6.In a 3-phase 4-wire 400/230 V system a lamp of 100 watts is connected to one phase and
neutral and a lamp of 150watts is connected to the second phase and neutral. If the neutral wire is
disconnected accidentally, what will be the voltage across each lamp?

The lamp L1 of 100 Watts is connected between phase R and neutral Lamp L2 of 150 watts is connected
between phase Y and the neutral.

1.16. Consequence of disconnection of neutral in three phase four wire system

34
Resistance of lamp L1, R1 = = 529 Ω i.e. [R = ]

Resistance of Lamp L2, R2 = = 352.67 Ω

When the neutral wire is disconnected as shown infig the two lamps are connected in series. Therefore the
potential difference across the combination becomes equal to the line voltage EL(400V)

Now current through lamps, I = = = 0.454 A

Voltage across lamp L1 = IR1= 0.454 x 529 = 240.17 V

Voltage across lamp L2 = IR2 = 0.454 x 352.67 = 160.11V

From the above the voltage across 100 watt lamp is increased to 24 V whereas voltage across
150 watt lamp is decreased to 160V. Therefore 100 W lamps become brighter and 150W
becomes dim.

REVIEW QUESTIONS

Part A & B

1. What is the voltage rating of Distribution Substation?


2. Mention the types of Electrical power distribution System?
3. List the types of Bus Bar arrangements?
4. Draw & explain the parts of Typical distribution system?
5. List the advantages of Ring Main Distribution system?
6. Draw the Schematic Diagram of Radial Distribution System?
7. State the different types of Connection schemes of Distribution system?
8. What is meant by feeder and distributor in distribution system?
9. What is the purpose of using auxiliary bus bar in bus bar arrangement?
10. What is the Effect of unbalanced load in star connected System?
11. What is transformer Substation?
12. State the advantages of Outdoor substation Over Indoor Substation.
13. What is the use of Instrument transformer in Substation?
14. State the classification of substation.
15. What are the advantages of Inter connected system?
16. Draw the layout of 110/11kV substation.
17. Distinguish between primary and secondary distribution system.
18. Compare radial and ring distribution system.
19. What are the classifications of bus bar system.
20. Explain single bus bar system
21. Explain double bus bar system with diagram.
22. Name some of the substation equipment’s.
23. What are the advantages of GIS.
24. What are the disadvantages of GIS.
25. What are the features of GIS.

Part C
1. Discuss the different types of Bus bar arrangements.
2. Draw the layout of 11kv/400v Distribution substation and explain the necessity of each part.

35
3. Explain the methods of solving AC distribution calculation referring power factor.
4. List and explain various equipments used in substation.
5. Classify the distribution systems based on types of supply, character of service, type of construction
and scheme of connections.
6. Explain the consequences of disconnection of neutral in 3phase 4wire AC distribution system.
7. Explain 3 phase, 4 wire star connected unbalanced load circuit in detail.
8. Classify the substation according to service and constructional features.
9. Explain various connection schemes of distribution system.
10. Explain the gas insulated substation in detail.
11. A single phase distributor one km long has resistance and reactance per conductor of 0.1Ω and
0.15Ω respectively. At the far end the voltage VB=200V and the current is 100A at a pf of 0.8
lagging. At the midpoint M of the distributor a current of 100A is tapped at a pf 0.6 lagging with
reference to the voltage Vm at the midpoint calculate i)Voltage at mid point ii)Sending end voltage
VA iii)Phase angle between VA and VB.
12. A single phase distributor 2 kilometers long supplies a load of 120 A at 0.8pr lagging at its far end
and a load of 80A at 0.9 pf lagging at its mid point. Both power factors are referred to the voltage at
the far end. The resistance and reactance per km(go and return) are 0.05Ω and 0.1Ω respectively. If
the voltage at the far end is maintained at 230V.calculatei)Voltage at the sending end.
ii) Phase angle between voltage at the two ends.
13. Discuss the different types of Bus bar arrangements.
14. Draw the layout of 11kv/400v Distribution substation and explain the necessity of each part.
15. Explain the methods of solving AC distribution calculation referring power factor.
16. List and explain various equipments used in substation.
17. Classify the distribution systems based on types of supply, character of service, type of construction
and scheme of connections.
18. Explain the consequences of disconnection of neutral in 3phase 4wire AC distribution system.
19. Explain 3 phase, 4 wire star connected unbalanced load circuit in detail.
20. Classify the substation according to service and constructional features.
21. Explain various connection schemes of distribution system.
22. Explain the gas insulated substation in detail.
23. A single phase distributor one km long has resistance and reactance per conductor of 0.1Ω and
0.15Ω respectively. At the far end the voltage VB=200V and the current is 100A at a pf of 0.8
lagging. At the midpoint M of the distributor a current of 100A is tapped at a pf 0.6 lagging with
reference to the voltage Vm at the midpoint calculate i)Voltage at mid point ii)Sending end voltage
VA iii)Phase angle between VA and VB.
24. A single phase distributor 2 kilometers long supplies a load of 120 A at 0.8pr lagging at its far end
and a load of 80A at 0.9 pf lagging at its mid point. Both power factors are referred to the voltage at
the far end. The resistance and reactance per km(go and return) are 0.05Ω and 0.1Ω respectively. If
the voltage at the far end is maintained at 230V.calculatei)Voltage at the sending end.
ii) Phase angle between voltage at the two ends.

36
UNIT II
INDUSTRIAL DRIVES

INTRODUCTION:

An industrial drive System basically consists of a mechanical working equipment or load which has to be
kept in motion to turn out mechanical work equipment to do this job called the prime mover and a
transmission to transfer energy from the prime mover to the mechanical load. Transmission equipment such
as a gearing or belt may be used to match the speeds of the prime mover and the load. The transmission may
also be required sometimes to convert rotator to linear motion and vice versa. Thus a combination of a
prime mover transmission equipment and mechanical working load is called a drive.

2.1. Electric drive:

An electric drive can be defined as a drive using an electric motor as a prime mover and ultimately
converting electrical energy to mechanical energy. The electric motors used may require some types of
control equipment to achieve speed control and torque control. These controls make the motor work on a
specific speed torque curve and may be operated using open loop or closed loop control

a) Advantages of Electric Drive

Almost all modern industrial and commercial undertakings employ electric drive in preference to
mechanical drive because it possesses the following advantages:

1. It is simple in construction and has less maintenance cost

2. Its speed control is easy and smooth

3. It is neat, clean and free from any smoke or flue gases

4. It can be installed at any desired convenient place thus affording more flexibility in the layout

5. It can be remotely controlled

6. Being compact, it requires less space

7. It can be started immediately without any loss of time

8. It has comparatively longer life.

b) Disadvantages:

1. It comes to stop as soon as there is failure of electric supply and

2. It cannot be used at far off places which are not served by electric supply.

However, the above two disadvantages can be overcome by installing diesel-driven dc generators and
turbine-driven 3-phase alternators which can be used either in the absence of or on the failure of normal
electric supply.

37
2.2. Parts of drive:

The above discussion makes clear that an electric drive system basically consists of a mechanical load to
which the required mechanical motion is imparted through a transmission drive usually equipped with gears
or pulleys Gearless transmission is possible sometimes in which case there exists a direct coupling between
the motor and load. The system also compresses certain controls for the motor for precise adjustment of the
speed torque curve as demanded by the mechanical load. Electrical drive has three parts namely

1. Motors

2. Load

3. Control unit

1. Motor:

A motor and its controls have to be selected to suit the given power supply and drive the load. The motors
may be selected as per the load requirements. Motors commonly used in electric drives are

1. D.C. moors – Shunt, Series motor, compound motor.

2. Induction motor – Squirrel cage, Slipring motor.

3. Synchronous motor.

4. Brushless D.C. motor, Stepper motor and reluctance motor.

2. Load

The load which is connected with the shaft of electric motor is called as mechanical load. The load may be
connected with the motor shaft directly or by using belt, chain, gear drives. The mechanical load and its
characteristics are normally specified by means of its load diagram and torque speed curve

3. Control unit

In modern electric drives, automatic operations are performed, i.e., starting, speed control of motors,
braking, reversing. All these functions are performed by electronic circuit using programmable logic
controllers, micro controller.

The function of the control equipment is to set the desired speed or torque precisely. Untill the advent of
thyristors, and associate power converters the speed control of motors had been achieved by means of
contactors and relays which include or cut off the resistors. The development
of power converters has made the control of motors quite straightforward.
With this help the speed of ac motors is also smoothly variable. The element
of a drive system when converters are employed are shown

2.3. Transmission of Power

There are many ways of transmitting mechanical power developed by a


motor to the driven machine.
1. Direct Drive: In this case, motor is coupled directly to the driven
machine with the help of solid or flexible coupling. Flexible coupling helps
in protecting the motor from sudden jerks. Direct drive is nearly 100%
efficient and requires minimum space but is used only when speed of the
driven machine equals the motor speed.

38
2. Belt Drive: Flat belts are extensively used for line-shaft drives and can transmit a maximum power
of about 250 kW. Where possible, the minimum distance between the pulley centers should be 4 times the
diameter of the larger pulley with a maximum ratio between pulley diameters of 6 : 1. The power
transmitted by a flat belt increases in proportion to its width and varies greatly with its quality and
thickness. There is a slip of 3 to 4 per cent in the belt drive.
3. Rope Drive: In this drive, a number of ropes are run in V-grooves over the pulleys. It has negligible
slip and is used when the power to be transmit-ted is beyond the scope of belt drive.

4. Chain Drive: Though somewhat more expensive, it is more efficient and is capable of transmitting
larger amounts of power. It is noiseless, slip less and smooth in operation.

5. Gear Drive: It is used when a high-speed motor is to drive a low-speed machine. The coupling
between the two is through a suitable ratio gear box. In fact motors for low-speed drives are manufactured
with the reduction gear. Geared Motor Unit incorporated in the unit itself. Fig. shows such a unit consisting
of a flange motor bolted to a high-efficiency gear box which is usually equipped with feet, the motor being
overhung.

2.4. Types of Electric Drives:

Electric drives may be grouped into three categories:


1. Group drive,
2. Individual drive and
3. Multi motor drive.

1. Group drive

In group drive, a single motor drives a number of machines through belts from a common shaft. It is
also called line shaft drive.

Fig 2.1.The group drive

Advantages:

1. It leads to saving in initial cost because one 150-kW motor costs much less than ten 15-kW motors
needed for driving 10 separate machines.

2. Since all ten motors will seldomly be required to work simultaneously, a single motor of even 100-
kW will be sufficient to drive the main shaft. This diversity in load reduces the initial cost still further.

3. Since a single large motor will always run at full-load, it will have higher efficiency and power
factor in case it is an induction motor.

39
4. Group drive can be used with advantage in those industrial processes where there is a sequence of
continuity in the operation and where it is desirable to stop these processes simultaneously as in a flour mill.

Disadvantages:

1. Any fault in the driving motor renders all the driven equipment idle. Hence, this system is unreliable

2. If all the machines driven by the line shaft do not work together, the main motor runs
At reduced load. Consequently, it runs with low efficiency and with poor power factor.

3. Considerable amount of power is lost in the energy transmitting mechanism.

4. Flexibility of layout of different machines is lost since they have to be so located as to suit the
position of the line shaft.

5. The use of line shaft, pulleys and belts etc. making the drive look quite untidy and less safe to
operate.

6. It cannot be used where constant speed is required as in paper and textile industry.

7. Noise level at the worksite is quite high.

2. Individual drive

In the case of an individual drive, each machine is driven by its own separate motor with the help of
gears, pulley etc.

Fig 2.2. Individual Drive

Advantages
1. Since each machine is driven by a separate motor, it can be run and stopped as desired.
2. Machines not required can be shut down and also replaced with a minimum of dislocation.
3. There is flexibility in the installation of different machines.
4. In the case of motor fault, only its connected machine will stop whereas others will continue
working undisturbed.
5. The absence of belts and line shafts greatly reduces the risk of accidents to the operating personnel.
6. Ach operator has full control of the machine which can be quickly stopped if an accident occurs.
7. Maintenance of line shafts, bearings, pulleys and belts etc. is eliminated. Similarly there is no
danger of oil falling on articles being manufactured–something very important in textile industry.

The only disadvantage of individual drive is its initial high cost. However, the use of individual drives

40
and multimotor drives has led to the introduction of automation in production processes which, apart from
increasing the productivity of various undertakings, has increased the reliability and safety of operation

3. Multi motor drive.

Fig 2.3 Multi motor drive


In multi-motor drives separate motors are provided for actuating different parts of the driven
mechanism. For example, in travelling cranes, three motors are used: one for hoisting, another for long
travel motion and the third for cross travel motion. Multimotor drives are commonly used in paper mills,
rolling mills, rotary printing presses and metal working machines etc.

2.5. Factors governing the Selection of a Motor


The selection of a driving motor depends primarily on the conditions under which it has to operate and
the type of load it has to handle. Main guiding factors for such a selection are as follows :
(a) Electrical characteristics
1. Running characteristics
2. Starting characteristics
3. Speed control
4. Braking
(b) Mechanical considerations
1. Types of enclosures
2. Transmission of drive
3. Type of cooling
4. Noise level
5. Type of bearing
(c) Size and rating of motors
1. Requirement for continuous, intermittent or variable load cycle
2. Overload capacity
(d) Cost
1. Capital cost2. Running cost
In addition to the above factors, one has to take into consideration the type of current available whether
alternating or direct. However, the basic problem is one of matching the mechanical output of the motor
with the load requirement i.e. to select a motor with the correct speed/torque characteristics as demanded by
the load. In fact, the complete selection process requires the analysis and synthesis of not only the load and
the proposed motor but the complete drive assembly and the control equipment which may include
rectification or frequency changing.

I). Electrical characteristics


a) Running characteristics:
The Running characteristics of a motor include the speed- torque or the speed- current characteristics,

41
Losses, magnetizing current, efficiency and power factor at various loads. The magnetizing current and
power factor are to be considered in case of AC motors only.

b) Starting characteristics:
The starting torque developed by a motor should be sufficient to start and accelerate the motor at its load to
the rated speed in a reasonable time. Some motors may have to start against full load torque example:
motors driving grinding mills or oil expellers, traction work.

c) Speed control:
i) In a DC motor the speed can be controlled by the following methods:
1. Armature control method
2. Field control method
ii) In AC motor the speed can be controlled by the following methods
1. By changing the supply voltage
2. By changing the supply frequency
3. By changing the number of poles of motor
4. By injecting emf in the rotor circuit.
5. By cascading of motors.
6. By injecting resistance in the rotor circuit.

d) Braking
If the load is removed from an electric motor and even the supply is disconnected, the motor will run for
some time due to its inertia. To avoid danger to the worker or to stop the motor immediately braking is
applied. The braking should be reliable and quick in action. The braking torque is applied to stop the motor.
There are two types of braking i0Mechanical Braking ii) Electrical braking.

(II) Mechanical characteristics

a)Types of Enclosures

The main function of an enclosure is to provide protection not only to the working personnel but also to
the motor itself against the harmful ingress of dirt, abrasive dust, vapors and liquids and solid foreign bodies
such as a spanner or screw driver etc. At the same time, it should not adversely affect the proper cooling of
the motor. Hence, different types of enclosures are used for different motors depending upon the
environmental conditions. Some of the commonly used motor enclosures are as under:

1. Open Type: In this case, the machine is open at both ends with its rotor being supported on
pedestal bearings or end brackets. There is free ventilation, since the stator and rotor ends are in free contact
with the surrounding air. Such, machines are housed in a separate neat and clean room. This type of
enclosure is used for large machines such as d.c. motors and generators.

2. Screen Protected Type: In this case, the enclosure has large openings for free ventilation.
However, these openings are fitted with screen covers, which safeguard against accidental contacts and rats
entering the machine but afford no protection from dirt, dust and falling water. Screen-protected type
motors are installed, where dry and neat conditions prevail without any gases or fumes.

3. Drip Proof Type: This enclosure is used in very damp conditions i.e. for pumping sets. Since
motor openings are protected by over-hanging cowls, vertically falling water and dust are not able to enter
the machine.
4. Splash-proof Type: In such machines, the ventilating openings are so designed that liquid or dust

42
particles at an angle between vertical and 100° from it cannot enter the machine. Such type of motors can be
safely used in rain.

5. Totally Enclosed (TE) Type: In this case, the motor is completely enclosed and no openings are left
for ventilation. All the heat generated due to losses is dissipated from the outer surface which is finned to
increase the cooling area. Such motors are used for dusty atmosphere i.e. sawmills, coal-handling plants and
stone-crushing quarries etc.
6. Totally-enclosed Fan-cooled (TEFC) Type: In this
case, a fan is mounted on the shaft external to the totally enclosed
casing and air is blown over the ribbed outer surfaces of the
stator and end shields (Fig. 44.1). Such motors are commonly
used in flour mills, cement works and sawmills etc. They require
little maintenance apart from lubrication and are capable of
giving years of useful service without any interruption of
production.

7. Pipe-ventilated Type: Such an


Enclosure is used for very dusty surroundings. Fig. 44.1. A three-phase motor

The motor is totally enclosed but it is cooled by neat and clean air brought through a separate pipe from
outside the dust-laden area. The extra cost of the piping is offset by the use of a smaller size motor on
account of better cooling.

8. Flame-proof (FLP) Type: Such motors are employed in atmospheres which contain in-flammable gases
and vapors i.e. in coal mines and chemical plants. They are totally enclosed but their enclosures are so
constructed that any explosion within the motor due to any spark does not ignite the gases outside. The
maximum operating temperature at the surface of the motor is much less than the ignition temperature of the
surrounding gases.

b) Bearings
These are used for supporting the rotating parts of the machines and are of
two types:
1. Ball or roller bearings 2. Sleeve or bush bearings

(a) Ball Bearings


Up to about 75kW motors, ball bearings are preferred to other bearings
because of their following advantages:

1. They have low friction loss


2. They occupy less space
3. They require less maintenance
4. Their life is long.
5. Their use allows much smaller air-gap between the stator and rotor of an induction motor.

Their main disadvantages are with regard to cost and noise particularly at high motor speeds.

(b) Sleeve Bearings


These are in the form of self-aligning pourous bronze bushes for fractional kW motors and in the
Form of journal bearings for larger motors. Since they run very silently, they are fitted on super-silent
motors used for driving fans and lifts in offices or other applications where noise must be reduced to the

43
absolute minimum.

(c) Noise
The noise produced by a motor could be magnetic noise, windage noise and mechanical noise. Noise
level must be kept to the minimum in order to avoid fatigue to the workers in a workshop. Similarly, motors
used for domestic, hospital appliances; offices and theatres must be almost noiseless. Transmission of noise
from the building, where the motor is installed to another building can be reduced if motor foundation is
flexible i.e. has rubber pads and spring.

2.6. Nature and classification of load torque

The mechanical system is coupled to the motor by means of a transmitting device. The motor has to develop
a torque as required by the mechanical work to be carried out to drive the load and the mechanical losses
occurring in the system. A mechanical system is specified by a speed torque curve. The motor while driving
this mechanical load must provide enough torque to drive the load against losses like friction and to
accelerate the load torque to the desired speed.

A) Windage torque

The torque required by the load when the air surrounding the rotating parts moves. It is normally
proportional to the square of the speed. However at normal speeds of operation it may be considered
equivalent to viscous friction and the value of B may be taken to contain both friction and windage.

The working mechanism must be accelerated and brought to the desired speed. The motor should provide a
torque at the shaft capable of accelerating the rotating parts against their inertia. Inertia as seen by the motor
shaft includes the inertia of the mechanism as well as of transmission.

Hence the load torque required by the load at the shaft has the following components.

 Torque component to overcome friction and windage which accompanies mechanical motion.T fw
 Torque required to accelerate the load to the desired speed.Ta
 Torque required to do the prescribed mechanical work to run to the load at the desired speed.Tw

The load torque seen by the motor at the shaft.

TL=Tfw+Ta+Tw

The friction existing in a mechanical system may be classified as follows

i) Viscous friction. In this type of friction the torque required is directly proportional to the speed of
rotation.

TB=Bw=B

Where B is a constant of proportionally

ii) Colomb friction .The torque required is independent of speed in this type of friction. It acts as a load
torque in either direction and is also called dry friction. Viscous friction changes to coulomb friction at very
low speeds

iii) Static friction or station Occurs due to the sticking nature of the surfaces. This is generally very small
and can be neglected.

44
2.7. Matching of speed torque characteristics of load and motor.

The various types of load torques that occur in industrial practices are considered with matching the speed
torque characteristics of load and motor for its specific applications.

The load torque may be constant at all speeds as shown curve in fig2.4 .curve a.This type of torque is
represented by a compressor load.

The speed torque curve b is as shown is for unidirectional drives.

Fig 2.4 Speed torque characteristics

The torque speed curve c is shown with certain types of loads like winch drives a constant torque is required
when the mechanism is under standstill conditions. The direction of rotation may need to be reversed.These
occur in ships when it is required to hold he ship in a particular location or to warp it through a lock gate.

Another type of load has its torque proportional to the square of the speed as in fig .The speed torque curve
is found with pump or fan type loads.

Tw=K

The power developed at the motor shaft

P=K

This load is also unidirectional. It is required to run at constant speeds for a longer period of time or at
several speed settings or over a range of speeds

Another type of mechanical load requires constant power at all speeds

Pw=Tw 

P constant at all w. The torque speed characteristic of such a load is a rectangular hyperbola. This load is
found with steel rolling mills papers mills. It occurs in transportation also.

45
Fig 2.5 Load torque characteristics

From the above types of loads some operates only in one direction with no reversal of speed. In the speed –
torque plane these are represented in the first quadrant. The forward driving of the mechanism corresponds
to an operation in the first quadrant where motor draws electrical power to drive the mechanical load
coupled to it.

The mechanical load sometimes requires braking to bring it to rest quickly. During braking, which torque is
achieved either by electrical or mechanical method is applied in the negative direction. Electrical methods
are dynamic braking, eddy current braking, regenerative braking and plugging.

2.8. Size and Rating of motor:

The factors which govern the size and rating of motor for any particular service are its maximum
temperature rise under given load conditions and the maximum torque required. It is found that a motor
which is satisfactory from the point of view of maximum temperature rise usually satisfies the requirement
of maximum torque as well. For class-A insulation, maximum permissible temperature rise is 40oC whereas
for class – B insulation, it is 50oC. This temperature rise depends on whether the motor has to run
continuously, intermittently or on variable load.

Different ratings for electrical motors are as under:

1. Continuous Rating. It is based on the maximum load which a motor can deliver for an indefinite
period without its temperature exceeding the specified limits and also possessing the ability to take 25%
overload for a period of time not exceeding two hours under the same conditions.

For example, if a motor is rated continuous 10 KW, it means that it is capable of giving an output of 10
KW continuously for an indefinite period of time and 12.5 KW for a period of two hours without its
temperature exceeding the specified limits.

2. Continuous Maximum Rating. It is the load capacity as given above but without overload capacity.
Hence, these motors are a little bit inferior to the continuous-rated motors.

3. Intermittent Rating. It is based on the output which a motor can deliver for a specified period, say
one hour or ½ hour or ¼ hour without exceeding the temperature rise. This rating indicates the maximum

46
load of the motor for the specified time followed by a no-load period during which the machine cools down
to its original temperature.

2.9 Classes of load duty cycles

The eight standard classes of duty cycles are


1. Continuous duty
2. Short time duty
3. Intermittent periodic duty
4. Intermittent periodic duty in the starting
5. Intermittent periodic duty with staring and braking
6. Continuous duty intermittent periodic loading
7. Continuous duty with staring and braking
8. Continuous duty with periodic speed changes.

2.10. Selection of motor for different duty cycles

1. Continuous duty (fig 2.6)

It denotes the motor operation at a constant load torque to reach steady state temperature. The load time and
temperature time graph are shown. Paper mill drives compressors conveyers’ centrifugal pumps and fans
are some examples of continuous duty.

2. Short time duty

It denotes the operation of motor at constant load for short period followed by rest to cool down to the
original starting temperature. Short time duty timings are generally 10, 30, 60 and 90 minutes. The load
time and the temperature time graph are shown. Crane drivers for household appliances sluices gate drives
valve drives and machine tool drives are some examples of short-time duty

3. Intermittent periodic duty (Fig 2.7)

It denotes the operation of motor a sequence of identical duty cycle each of constant load and rest period. In
this duty heating of machine during starting and braking operation is negligible. The load time and
temperature time graph. Pressing cutting and drilling machine drives are some examples of intermittent
periodic duty.

47
4. Intermittent period duty with starting

This is intermittent periodic duty where heat losses during starting cannot be neglected. Thus it consists of a
period of starting a period of operation at a constant load and rest period. The operating and rest periods are
too short to attain the steady state temperature in one duty cycle. Its characteristics are shown In this duty
heating of machine during braking is considered to be negligible .Some examples are metal cutting drilling
tool drives mine hoist drives for lift trucks.

5. Intermittent periodic duty with starting and braking (2.8)

This is the periodic duty where heat losses during starting and braking cannot be ignored. Thus it consists of
a period of starting a period of operation with a constant load a braking period and a rest period. Thermal
equilibrium is not reached in one duty cycle. Braking is done electrically and is quick. Its characteristics is
Several machine tool drives, drives for electric suburban trains and mine hoist are some examples of this
duty.

6. Continuous duty with intermittent periodic loading(Fig 2.9)

The operation of motor has a sequence of identical duty cycle each consisting of a period of operation and a
period of operation on no load. Thermal equilibrium

48
2.11. Motors for Different Industrial Drives

1. D.C. Series Motor: Since it has high starting torque and variable
speed, it is used for heavy duty applications such as electric locomotives,
steel rolling mills, hoists, lifts and cranes.

2. D.C. Shunt Motor: It has medium starting torque and a nearly


constant speed. Hence, it is used for driving constant-speed line shafts,
lathes, vacuum cleaners, wood-working machines, laundry washing
machines, elevators, conveyors, grinders and small printing presses etc.

3.Cumulative Compound Motor: It is a varying-speed motor with high


starting torque and is used for driving compressors, variable-head
centifugal pumps, rotary presses, circular saws, shearing machines, elevators and continuous conveyors etc.

4. Three-phase Synchronous Motor: Because its speed remains constant under varying loads, it is
used for driving continuously-operating equipment at constant speed such as ammonia and air compressors,
motor-generator sets, continuous rolling mills, paper and cement industries.

5. Squirrel Cage Induction Motor: This motor is quite simple but rugged and possesses high over-
load capacity. It has a nearly constant speed and poor starting torque. Hence, it is used for low and medium
power drives where speed control is not required as for water pumps, tube wells, lathes, drills, grinders,
polishers, wood planers, fans, blowers, laundry washing machines and compressors etc.

6. Double Squirrel Cage Motor: It has high starting torque, large overload capacity and a nearly
constant speed. Hence, it is used for driving loads which require high starting torque such as compressor
pumps, reciprocating pumps, large refrigerators, crushers, boring mills, textile machinery, cranes, punches
and lathes etc.

7. Slip-ring Induction Motor: It has high starting torque and large overload capacity. Its speed can be
changed up to 50% of its normal speed. Hence, it is used for those industrial drives which require high
starting torque and speed control such as lifts, pumps, winding machines, printing presses, line shafts,

49
elevators and compressors etc.

8. Single-phase Synchronous Motor: Because of its constant speed, it is used in teleprinters, clocks,
all kinds of timing devices, recording instruments, sound recording and reproducing systems.

9. Single-phase Series Motor: It possesses high starting torque and its speed can be controlled over a
wide range. It is used for driving small domestic appliances like refrigerators and vacuum cleaners etc.

10. Repulsion Motor: It has high starting torque and is capable of wide speed control. More-over, it
has high speed at high loads. Hence, it is used for drives which require large starting torque and adjustable
but constant speed as in coil winding machines.

11. Capacitor-start Induction-run Motor:It has fairly constant speed and moderately high starting
torque. Speed control is not possible. It is used for compressors, refrigerators and small portable hoists.

12. Capacitor-start-and-run Motor. Its operating characteristics are similar to the above motor except
that it has better power factor and higher efficiency. Hence, it is used for drives requiring quiet operations

2.12. Electrical braking:

The stored energy of rotating parts is converted into electrical energy and dissipated in the resistance in the
form of heat or returned to the supply in case of electrical braking. In electrical braking the driving motor
operates as a generator during the period of braking and comes to standstill.

a)Advantages of Electrical Braking :

1. The electrical braking is more economical than mechanical braking.


2. Wear and tear of brake will not take place.
3. Mechanical braking produces metal dust, which can damage bearings. Electrical braking has no
such high maintenance problems.
4. Comfort, easy speed control.
6. Electrical braking is smooth, fast and cheap.
7. In regenerative braking electrical energy can be returned back to the supply so running cost is less.
8. Noise produced is very low.
9. Capacity of the system can be increased.

b) Disadvantages:
1. It is ineffective in applying holding torque.
2. High initial cost.
3. Cannot be applied to all types of motors

2.13. Types of Electric Braking

There are three types of electric braking as applicable to electric motors in addition to eddy-current
braking.

1. Plugging or reverse-current braking.

2. Rheostat or dynamic braking.

50
3. Regenerative braking.

In many cases, provision of an arrangement for stopping a motor and its driven load is as important as
starting it. For example, a planner machine must be quickly stopped at the end of its stroke in order to
achieve a high rate of production. In other cases, rapid stops are essential for preventing any danger to
operator or damage to the product being manufactured. Similarly, in the case of lifts and hoists, effective
braking must be provided for their proper functioning.

1. Plugging

Plugging means phase reversal. It is a simple method of electrical braking. During the braking period
reverse torque produces on the motor. A special device is required to cut off the supply as soon as the motor
comes to rest. This method can be applied to both AC and DC motors.

a) Plugging Applied to D.C. Motors

With reversed armature connections, the motor develops torque in the opposite direction. So, armature
connections are reversed whereas field winding connections remain unchanged. When speed reduces to
zero, motor will accelerate in the opposite direction. Hence, the arrangement is made to disconnect the
motor from the supply as soon as it comes to rest.

b) Plugging Applied to D.C. Shunt Motors (Fig 2.11)


Fig. shows running and reversed connections for shunt motors. In this back emf (Eb) opposes the
applied voltage (V). The armature current flows from A to B. When plugging is applied the armature
connections are reversed as in fig. Since with reversed connection, V and Eb are in the same direction,
voltage across the armature is almost double of its normal value. In order to avoid excessive current through
the armature, additional resistance R is connected in series with armature

C)Plugging Applied to D.C. Series Motors(Fig 2.12)

Fig. shows similar conditions for series motors. In DC series motor. In series motor while plugging the
field current is also reversed. These results the production of the torque in the same as it is working
normally. In order to develop torque in the reverse direction, the direction of field current should remain

51
unchanged. At this time now a total voltage (V+Eb) is available across the armature terminals. It will be
nearly twice of the supply voltage. It may causes high current to flow around the circuit. To limit this
current additional resistance R is connected in series. This method is simple but power is wasted in the
resistance.

d) Plugging Applied to Induction Motors


This method of braking is applied to an induction motor by transposing any of its two line leads as
shown in Fig. It reverses the direction of rotation of the synchronously-rotating magnetic field which
produces a torque in the reverse direction, thus applying braking on the motor. Hence, at the first instant
after plugging, the rotor is running in a direction opposite to that of the stator field. At the instant of
plugging the relative speed between the rotor conductors and the magnetic field will be twice the
synchronous speed. So voltage induced in the rotor will be twice that of normal voltage. It means that speed
of the rotor relative to the magnetic field is(Ns + N) ≅ 2Ns as shown in Fig.

In Fig.2.13. Plugging Applied to Induction Motors

Coordinate BC represents the braking torque at the instant of plugging. As seen, this torque gradually
increases as motor approaches standstill condition after which motor is disconnected from the supply. Due
to high voltage, abnormal current will flow so in order to protect the windings additional insulation to be
provided. Hence high value of resistance may be inserted in the rotor or stator circuit.

e) Plugging Applied to Synchronous Motors

As compared to squirrel cage motors, slip-ring motors are more suitable for plugging because, in their case,
external resistance can be added to get the desired braking torque. When three phase voltage is supplied to
the stator of Synchronous Motors a rotating magnetic field is produced in the stator. D.C voltage is applied
to the rotor field windings producing permanent magnetic field. If the direction of rotating magnetic field is
reversed by interchanging the two phases of the stator then the braking torque is not produced. Therefore in
case of plain Synchronous Motors plugging is not possible. But in case of self-started Synchronous Motors
the braking effect will be produced due to eddy current induced in damper windings provided for starting
purpose.

2. Dynamic or Rheostat Braking

This method has advantage over plugging because, in this case, no power is drawn from the supply during
braking. In his method of braking, a motor is disconnected from the supply and operated as a generator
driven by the kinetic energy of the rotor. The kinetic energy of rotation is converted in to electrical energy,

52
in which the energy is dissipated in external resistor.D.C. and synchronous motors can be broken this way
but induction motors require separate d.c.source for field excitation.

a) Dynamic or Rheostat Braking of D.C.shunt Motors

Fig2.14.a. shows connections for a D.C. shunt motor. For applying rheostat braking armature is
disconnected from the supply and connected to a variable external resistance R while the field remains on
the supply. The motor starts working as a generator whose induced emf Eb depends upon its speed. At the
start of braking, when speed is high, Eb is large, hence Ia is large. As speed decreases, Eb decreases, hence Ia
decreases. Since Tb α Φ Ia, it will be high at high speeds but low at low speeds. By gradually cutting out R, Ia
and, hence, TB can be kept constant throughout. Value of Ia = Eb (R + Ra).

a) Dynamic or Rheostat Braking of D.C. series Motors

Fig2.14.b. shows running and braking conditions for a D.C. series motor. In this case also, for rheostat
braking, the armature is disconnected from the supply and, at the same time, is connected across R.
However, connections are so made that current keeps flowing through the series field in the same direction
otherwise no braking torque would be produced. The motor starts working as a series generator provide
Rheostat Braking Torque.

1. For D.C shunt motors and synchronous motor is constant hence T B = k1 N


2. In the case of series motors, flux depends on current. Hence, braking torque can be found from its
magnetization curve.

b) Dynamic or Rheostat Braking of Induction Motors

If an induction motor the stator is disconnected from the supply for rheostat braking, there would be no
magnetic flux and, hence, no generated emf in the rotor and no braking torque. However, if after

53
disconnection, direct current is passed through the stator; steady flux would be set up in the air-gap which
will induce current, in the short-circuited rotor. This current which is proportional to the rotor speed, will
produce the required braking torque whose value can be regulated by either controlling d.c. excitation or
varying the rotor resistance.

C) Dynamic or Rheostat Braking of Synchronous Motors

In synchronous motor, the D.C excitation is maintained and the stator is disconnected from the supply.
Then the stator is connected across three resistances in star or delta. Now the machine operates as an
alternator and the kinetic energy is dissipated in the resistance and braking will occur.

3. Regenerative Braking

In this method of braking, motor is not disconnected from


the supply but is made to run as a generator by utilizing the
Kinetic energy .Electrical energy is fed back to the supply. The
magnetic drag produced on account of generator action offers the
braking torque. It is the most efficient method of braking.

a) Regenerative Braking applied to D.C.shunt motor

Take the case of a shunt motor. It will run as a generator whenever its Eb be-comes greater than V. Now, Eb
can exceed V in two ways:

Fig 2.15.Regenerative Braking applied to D.C.shunt motor

1. By increasing field excitation


2. By increasing motor speed beyond its nor-mal value, field current remaining the same. It happens when
load on the motor has overhauling characteristics as in the lowering of the cage or a hoist or the down-
gradient movement of an electric train. Regenerative braking can be easily applied to D.C. shunt motors
though not down to very low speeds because it is not possible to increase field current sufficiently.

b) Regenerative Braking applied to D.C.series motor


In the case of D.C. series motors, reversal of current necessary to produce regeneration would cause reversal
of the field and hence of Eb . Consequently, modifications are necessary if regenerative braking is to be
employed with D.C. series motors. It may, however, be clearly understood that regenerative braking cannot
be used for stopping a motor. Its main advantages are (i) reduced energy consumption (ii) reduced wear of
brake shoes and wheel (iii) lower maintenance cost.

54
Fig 2.16.Regenerative Braking applied to D.C.series motor

Fig shows the connection of a D.C. series motor for Regenerative Braking using French method. It is
provided with a main series winding and auxiliary field winding connected in parallel with the main series
winding in a D.C series motor. During braking period, the auxiliary windings are put in series with each
other and switched across the supply as in fig. the motor acts as a differentially compound generator.

c) Regenerative Braking applied to induction motor

When an induction motor runs above synchronous speed the emf induced in the rotor is greater than the
supply voltage. Hence the motor works acts as an induction generator and feed power back to the supply
line. No extras auxiliaries are needed for this purpose. Its application is very useful to lift and hoist for a
descending load at a speed slightly above synchronous speed.

REVIEW QUESTIONS
Part-A& Part-B

1. Mention any one application area of group drive system?


2. What is Short time duty cycle?
3. What are the important parts of electric drives?
4. What is meant by Regenerative braking?
5. What is mean by Individual Drive system?
6. What is mean by rating of motor?
7. List the motors used for mining.
8. Why DC Series motor is used in Crane Drive?
9. What are the factors to be taken in to consideration while selecting a motor for industrial
applications?
10. What is plugging?
11. Write a Note on nature and Classification of load Torque?
12. What do you mean by group drive & individual drive .Give examples?
13. What are the factors to take into account for selection of driving motor?
14. Name the types of enclosures of Electric drives.

55
15. Name the types of Transmission of drive.
16. What is the effect of Noise? How it can be Limited?
17. How regenerative braking is achieved in AC Drive?
18. Bring out the difference between Regenerative Braking & Plugging.
19. List out the classification of duty cycles & explain.
20. State the advantages and Disadvantages of Electric Braking compare to Mechanical braking?
21. What is meant by continuous rating?

Part-C
22. Explain how regenerative braking is applied to DC shunt and DC series motor?
23. Explain the different types of electric drives used in industrial loads?
24. Give the choice of motors for the following giving Proper reasons
25. Lathe, Cement Kiln, Hoist, Textile mill, Paper Mill, Electric crane, Centrifugal Pump.
26. Explain Load duty cycles and how a motor is selected from a given duty cycles?
27. Explain Plugging and how it is carried out in a 3-pahse induction motor?
28. Explain dynamic braking is applied to DC shunt motor and 3-phase induction motor?
29. Explain the factors governing the selection of motors in detail.

56
UNIT III

ELECTRIC TRACTION
INTRODUCTION

The electric traction is meant locomotion in which the driving (or attractive) force is obtained from electric
motors. It is used in electric trains, tramcars, trolley buses and diesel-electric vehicles etc. Electric traction
has many advantages as compared to other non-electrical systems of traction including steam traction

3.1Traction Systems.

Traction systems can broadly speaking be classified as those which do not involve use of electrical energy
at any stage, such as steam engine drive and internal combustion engine drive and those traction systems
which involve use of electrical energy at some stage or the other, such as diesel electric drive battery electric
drive and straight electric drive.

Broadly speaking, all traction systems may be classified into two categories:

(a) Non-Electric traction systems

They do not involve the use of electrical energy at any stage. Examples are : steam engine drive used in
railways and internal-combustion-engine drive used for road transport

(b) Electric traction systems

They involve the use of electric energy at some stage or the other. They may be further sub-divided into
two groups:

1. First group consists of self-contained vehicles or locomotives. Examples are : batteryelectric drive and
diesel-electric drive etc.

2. Second group consists of vehicles which receive electric power from a distribution network fed at
suitable points from either central power stations or suitably-spaced sub-stations.

Examples are: railway electric locomotive fed from overhead ac supply and tramways and trolly buses
supplied with dc supply

3.2. Electric Drive:

Drives using by means of electric motors which are fed from over head distribution system are known as
electric drives.

3.3. Advantages and disadvantages of electric drive are:

a)Advantages

1. Cleanliness

As it has no smoke electric traction is most suited for the underground and tube railways. Because of
absence of smoke and spark there is not only greater safety in the drive but damage to buildings and
apparatus by corrosive fumes is not caused.

57
2. High starting torque

Due to high starting torque developed it is possible to achieve high acceleration rates of 1.5 to 2.5 Kmphs as
against 0.6 to 0.8 Kmphs in case of steam engine drive as a result of this we are able to achieve following

a) High schedule speed

Traffic handling capacity of electric traction is over double that of steam traction

b) Due to high Schedule speed and high traffic handling capacity less terminal space is required. This is an
important factor in urban areas.

3. Cleanliness:

Owing to cleaner quicker and more comfortable passenger travel and increased transport of goods it leads to
greater traffic density and greater industrialization

4. Power requirement:

Power requirement for railway electrification has been of the order of 50KW/track Km. This is sizeable load
which tends to increase power development schemes. Traction load has high load factor of the order of 60
to 70%. Electric traction therefore provides a most important base load. This therefore enables the use of
large generator units having high thermal efficiency possible in thermal stations. High base load also affords
economic development of hydro electric potential

5. Rural electrification:

Railway electrification encourages rural electrification as no special transmission lines have to be run for
this purpose

6. On account of release of wagons for the transport of coal for steam, locomotives greater availability of
rolling stock is obtained with railway electrification

7. Flexibility of operation

Traction system operating in urban and sub-urban areas, experiences heavy rush in the morning and
evening. At mid day the traffic is light. It is possible with motor coaches to run shorter trains.

8. Maintenance

Not only electric locomotive maintenance cost is about 50% of that of steam locomotive but it requires
much less maintenance time also.

9. It has very low starting time.

10 Easy to control the speed, braking..

11. Saving in high grade coals.

b) Disadvantages

1. Most vital factor against electric traction is high capital outlay on overhead supply system.

2. Power failure for few minutes can cause dislocation of traffic for hours

58
3. Communication lines which also run along with power lines experience interference.

4. Traction is tied up to electrified routes only.

SYSTEM OF TRACK ELECTRIFICATION

3.4. METHODS OF SUPPLYING POWER

There are two methods of supplying power to electric train

1. Rail conductor system.

2. Over head line system.

1. Rail Conductor system

Early day’s electric traction employed conductor rail system of supply of electric power to the traction units.
This was founded on the difficulties experienced in maintaining contact wire in level. This system of supply
has been used in many countries mainly for high density suburban traffic.

Fig 3.1Conductor rail system

In this system electric supply is collected from an insulated rail running parallel to the track at a distance of
0.3 to 0.4m from the running rails .However in underground system of traction in large cities insulated
return rail is used to eliminate any electrolytic action due to return currents on other public services buried
in the vicinity of the railway tunnels.

In majority of conductor rail systems, current collection is from the top surface of the rail but in certain
systems current collection is from sides or underside of conductor. Fail latter systems are supposed to be
more protective against accidental contact. Conductor rails are supposed to have low resistance and not as
much hardness as track rails as such these are of low carbon .05% and low manganese .02% content. To
reduce the voltage drop at joints conductor rails are bonded together by copper conductors riveted or welded
to the rails. Current is collected by steel shoes necessary contact pressure being obtained by gravity in the
case of top contact and by means of springs in case of side and under side contacts. At points and crossings
there is bound to be discontinuity in the conductor rail. Two collection brushes prevent any interruption in
the supply to the train. For this purpose conductor rail alternates between one side of the track and the other.
This also events out the wear on the collector shoes. In certain situations due to complicated track work or
due to safety reasons no conductor rails can be provided one such example is the level crossing with public
roadways.

2. Overhead line system:

59
In overhead line conductor system the track rail is used as the return path of the current. The current from
the overhead network is collected by using sliding contact collectors. There are two types of current
collecting equipments

3.5. Overhead Equipment (OHE)

1. Catenary and droppers

The first and foremost function in electric traction is to keep the traction unit fed with the energy that it
needs. For this purpose broadly speaking there are two systems of current collection namely from third rail
and from overhead wire. Current collection from overhead wire is far superior to that from the third rail this
is because both theoretically and experimentally current collection is more difficult from a rigid body than
from an elastic one.

Fig 3.2.Catenary and droppers

The maximum distance between the two consecutive supports with this system is restricted to 30m.Because
there is appreciable sag of wire between supports this limits the speed up to maximum of 30kmph.

The contact wire must be suspended with the minimum of sag so that it remains practically
horizontal to have a contact with the collector. This is achieved by centenary and droppers. In this system
the contact wire is suspended by the centenary wire by means of droppers. The droppers are fixed on
contact wire and centenary wire at equal distances. The length of the span for the centenary wire on a single
route varies with 45m to 90m. The distance between the droppers should be 3m to 5m. The sag in the
catenaries’ wire varies from 1m to 2m.this centenary wire provides a continuous contact with the conductor.

2. Current Collection Systems-Current Collection Gear for OHE

Main requirement of a collection gear is that it should, under no circumstances leave the contact of OHE.
Contact wire in all practical installation is never perfectly horizontal. It rises and falls depending upon the
weight of the contact wire and distance between droppers. Depending upon the speed of the electric vehicle
collection gear has to rise and fall in order to main train the contact with OHE. The various types of current
collection gears are Bow collector, Pantograph collectors, Pole collector, Cable collector…

a) Pole Collector

60
For tramways grooved gun metal wheel trolley collector of grooved slider shoe with carbon insert attached
to the end of long pole provided on the top of the car is used. Collector is held in contact with the wire by
means of spring the force of contact being 10kg.for wheel collector 17kg for carbon insert slider. The pole
can swivel about its support so that it is not necessary for trolley wire to run exactly in the centre of the
track. It is universally used for trolley buses to enable them to maneuver in traffic up to a distance of 4 to 5
meters from the contact wire. Trolley collector has to operate in trailing position. Main drawback of trolley
collector is that it has to be rotated by 180°before tramcar can have motion in the reverse direction. Trolley
collector is suitable for low speeds up to 22 to 30kmph beyond which it runs the risk of jumping off the
contact wire. Another drawback particularly with trolley wheel pole collector is that there is poor contact
between the wheel and trolley wire. This gives rise to high current density which results in heavy arcing. Its
use is therefore prohibited in gassy mines where pole collector with grooved slider shoe is preferred.

b)Bow Collector

Fig 3.3.Bow Collector

Main advantage of bow collector is that it can be used for higher speeds. Bow collector consists of two
trolley collector poles at the end of which is placed a light metal strip up to one meter long for current
collection. Although provision of metal strip enables the contact of trolley wire its maneuverability is lost. It
is as such not suitable for trolley buses. On tramway services trolley wire is hung at the center line of the
track with about 15cm.stagger to hive uniform wear of the strips and prevent formation of groove on it.
Collection strip is of soft material such as copper aluminum or carbon so that it should wear instead of
trolley wire as it is easy to replace wrong out collection strip than trolley wire. Bow collector has always to
run trailing just like trolley collector. It therefore requires either provision of duplicate bows or an
arrangement of reversing the bows for motion in the reverse direction.

Disadvantages:

 Poor current collecting capacity


 Irreversible operation is not possible

c) Pantograph collector:

The disadvantages of bow collectors are overcome by this type of collectors. Pantograph collectors always
maintain the link between the overhead lines.

61
Fig 3.4. Pantograph collector:

Its function is to maintain link between overhead contact wire and power circuit of the electric
locomotive at different speeds under all wind conditions and stiffness of OHE. It means that positive
pressure has to be maintained at all times to avoid loss of contact and sparking but the pressure must be as
low as possible in order to minimize wear of OH contact wire.

A ‘diamond’ type single-pan pantograph is shown in Fig. It consists of a pentagonal framework of high-
tensile alloy-steel tubing. It has a copper strip which acts as contact surface. The contact portion consists of
a pressed steel pan fitted with renewable copper wearing strips which are forced against the OH contact
wire by the upward action of pantograph springs. The pantograph can be raised or lowered from cabin by air
cylinders. It is used in the vehicles run at high speeds and current to be collected is 2000 to 3000 A.

Advantages:

1. It can operate in either direction of motion.

2. Risk of jumping off the collector is minimum

3. Erection of overhead network is simple.

4. Its height can be increased or decreased by simple operations from the drivers’ cabin.

3.6. Systems of Railway Electrification

Presently, following four types of track electrification systems are available:

1. Direct current system—600 V, 750 V, 1500 V, 3000 V

2. Single-phase ac system—15-25 kV, 16 2/3, 25 and 50 Hz

3. Three-phase ac system—3000-3500 V at 16 2/3 Hz

4. Composite system—involving conversion of single-phase ac into 3-phase ac or dc.

1. Single-Phase Low-frequency 25 Hz AC System

In this system, ac voltages from 11 to 15 kV at 16 2/3 or 25 Hz are used. If supply is from a generating
station exclusively meant for the traction system, there is no difficulty in getting the electric supply of 16 2/3

62
or 25 Hz. If, however, electric supply is taken from the high voltage transmission lines at 50 Hz, then in
addition to step-down transformer, the substation is provided with a frequency converter. The frequency
converter equipment consists of a 3-phase synchronous motor which drives a 1-phase alternator having or
25 Hz frequency.

The 15 kV 16 2/3 or 25 Hz supply is fed to the electric locomotors via a single over-head wire (running rail
providing the return path).

A step-down transformer carried by the locomotive reduces the 15-kV voltage to 300-400 V for feeding the
ac series motors. Speed regulation of ac series motors is achieved by applying variable voltage from the
tapped secondary of the above transformer.

Low-frequency ac supply is used because apart from improving the commutation properties of ac motors, it
increases their efficiency and power factor. Moreover, at low frequency, line reactance is less so that line
impedance drop and hence line voltage drop is reduced. Because of this reduced line drop, it is feasible to
space the substations 50 to 80 km apart. Another advantage of employing low frequency is that it reduces
telephonic interference

2. Advantages of 25-kV, 50-Hz AC System

Advantages of this system of track electrification over other systems particularly the dc systems are as
under:

a) Light Overhead Catenary

Since voltage is high (25 kV), line current for a given traction demand is less. Hence, cross-section of the
overhead conductors is reduced. Since these small-sized conductors are light, supporting structures and
foundations are also light and simple. Of course, high voltage needs higher insulation which increases the
cost of overhead equipment (OHE) but the reduction in the size of conductors has an overriding effect.

b) Less Number of Substations

Since in the 25-kV system, line current is less, line voltage drop which is mainly due to the resistance of the
line is correspondingly less. It improves the voltage regulation of the line which fact makes larger spacing
of 50-80 km between sub-stations possible as against 5-15 km with 1500 V dc system and 15-30 km with
3000 V dc system. Since the required number of substations along the track is considerably reduced, it leads
to substantial saving in the capital expenditure on track electrification.

c) Flexibility in the Location of Substations

Larger spacing of substations leads to greater flexibility in the selection of site for their proper location.
These substations can be located near the national high-voltage grid which, in our country, fortunately runs
close to the main railway routes. The substations are fed from this grid thereby saving the railway
administration lot of expenditure for erecting special transmission lines for their substations. On the other
hand, in view of closer spacing of dc substations and their far away location, railway administration has to
erect its own transmission lines for taking feed from the national grid to the substations which consequently
increases the initial cost of electrification.

d) Simplicity of Substation Design

In ac systems, the substations are simple in design and layout because they do not have to install and
maintain rotary converters or rectifiers as in dc systems. They only consist of static transformers along with
their associated switchgear and take their power directly from the high-voltage national grid running over
the length and breadth of our country. Since such sub-stations are remotely con-trolled, they have few

63
attending personnel or even may be unattended.

e) Lower Cost of Fixed Installations

The cost of fixed installations is much less for 25 kV ac systems as compared to dc system. In fact, cost is in
ascending order for 25 kV ac, 3000 V dc and 1500 V dc systems. Consequently, traffic densities for which
these systems are economical are also in the ascending order.

f) Higher Coefficient of Adhesion

The straight dc locomotive has a coefficient of adhesion of about 27% whereas its value for ac rectifier
locomotive is nearly 45%. For this reason, a lighter ac locomotive can haul the same load as a heavier
straight dc locomotive. Consequently, ac locomotives are capable of achieving higher speeds in coping with
heavier traffic.

g) Higher Starting Efficiency

An ac locomotive has higher starting efficiency than a straight dc locomotive. In dc locomotive supply
voltage at starting is reduced by means of ohmic resistors but by on-load primary or secondary tap-changer
in ac locomotives.

3. Disadvantages of 25-kV AC System

1. Single-phase ac system produces both current and voltage unbalancing effect on the supply.

2. It produces interference in telecommunication circuits. Fortunately, it is possible at least to minimize both


these undesirable effects.

3.7. Block Diagram of an AC Locomotive

The various components of an ac locomotive running on single-phase 25-kV, 50-Hz ac supply are numbered
in Fig.

1. OH contact wire
2. pantograph
3. Circuit breakers
4. on-load tap-changers
5. transformer
6. rectifier
7. smoothing choke
8. Dc traction motors.

Fig 3.5.Block Diagram of an AC Locomotive

As seen, power at 25 kV is taken via a pantograph from the overhead contact wire and fed to the step-down
transformer in the loco-motive. The low ac voltage so obtained is converted into pulsating dc voltage by
means of the rectifier. The pulsations in the dc voltage are then removed by the smoothing choke be-fore it
is fed to dc series traction motors which are mounted between the wheels.

64
Electric locomotive as collects current from over head equipment OHE through sliding contact with it by
means of pantograph air circuit breaker is provided on the roof of the locomotive and its main function is to
disconnect the locomotive from high voltage supply, by means of on load tap changer we can vary the
output voltage supply, by means of on load tap changer we can vary the output voltage for speed control of
traction motors by means of transformer high voltage of OHE is reduced to the utilization level by means of
rectifier as is rectified to dc smoothing choke reduces the magnitude of the undesirable effects on the proper
working of traction motor such as commutation and heating.

The function of circuit breakers is to immediately disconnect the locomotive from the overhead supply in
case of any fault in its electrical system. The on-load tap-changer is used to change the voltage across the
motors and hence regulate their speed.

a) Feeding post

Layout of feeding post is shown in normally there are two feeders running in between substation and
feeding posts. Each feeder has two conductors. One insulated for 25KV for connection to the bus bar and
the other for 3KV for connection to the track for return current. Cross section of the conductors is 20sq mm
of copper or 400 sq.mm of ACSR. These feeders are connected to two sets of bus bars of feeding post
through two oil circuit breakers. These two sets of bus bars are connected together through bus couplers
which along with input circuit breakers enable OHE to be fed even if one of the feeders is out of action for
maintenance purpose or due to fault. Feeding posts are located as close to the substation as possible
maximum distance being 2 km. usually 25KV circuit breakers of feeding post are controlled from a remote
control center of the railway. Interlocked double pole isolating switches are provided on both sides of every
circuit breaker to enable its complete isolation and to ensure full safety for maintenance staff. In the case of
two track lines there are four interrupters two for each feeder and supplying two tracks on one side of
feeding post only. Interrupters are single pole low oil content outdoor type oil switches meant to connect
different sections of OHE to feeding post. Interrupter is supposed to close or open for normal load
conditions only. Since it is not equipped with any protective relays to trip it automatically in the event of
fault as in the case of circuit breaker it is not meant for automatic braking of fault currents. Interrupters are
normally arranged for remote control operation but they have provision for manual operation if required

b) Feeding and Sectioning Arrangements

Power generation and transmission system of supply authorities are of 3 phase type. Electric traction on the
other hand needs single phase supply. If all the traction load is put on one phase only. It would bring about
unbalanced conditions. This besides causing inconvenience to other consumers due to phase shift is very
harmful to the alternator as it produces lot of rotor heating due to double frequency currents induced in the
rotor by rotating magnetic field produced by negative phase sequence currents. As such unbalanced
conditions beyond certain limit are not permitted to exist. Effort is therefore made to supply power to the
consecutive substation from difference phases in rotation. Zones fed by adjacent substations will therefore
be across different phases each acting as a separate independent unit and never working in parallel This is
quite contrary to the dc system where all the substations feed OHE in parallel. In order therefore to separate
the two sections of OHE fed from two adjacent substations .The purpose of providing neutral section is to
separate the zones fed by two adjacent substations so that it is not possible for a pantograph of electric train
to bridge two different live phases of 25kv supply while passing from the zone fed from preceding
substations to the zone fed by next substation. Since neutral section is dead it becomes necessary for the
driver of an electric train to switch off power before approaching neutral section and coast through it to the
other zone. For these warning boards are provided to draw the attention of driver.

3.8. Booster transformer – Necessity

65
In a.c. traction system, return current which flows from the locomotive to the track soon leaks to the
ground with in short distance and returns to the substation through its earth.

These ground current causes heavy interference with the communication lines. His current can be
minimized by using booster transformers. It consists of two windings of1: 1 ratio. The primary winding is
connected in series with contact wire. Any amount of current flowing through primary requires to be
balanced by equal current in secondary and so the tendency of current flowing through stray path is reduced.
There are two methods of connecting booster transformer.

1. Rail connected booster transformer.

2. Booster transformer with return feeder.

1. Rail connected booster transformer.

As in fig primary is connected in series with the contact line and secondary in series with rails. Induced
voltage in the secondary constraints the return current to flow through rails. This method of connecting
booster transformer has the following drawbacks.
1. Need insulated rail joint with small neutral sectioning.

2. Insulation puncture between rails of insulated joins may cause short circuiting the secondary and make
the booster transformer ineffective.

3. Voltage rises of 200v between rails and 100v between rail and earth may cause danger.

4. Requires close spacing of booster transformer.

Fig 3.6. Rail connected booster transformer.

2. Booster transformer with return feeder

This method is more effective than others. Fig shows the connection of booster transformer with return
feeder. In this system rails are connected midway between booster transformers. The return current now
flows through the return feeder back to substation. Running the return feeder very close to the contact wire
reduces the tendency of magnetic coupling between power line and telecommunication line. The turns of the
booster transformer should be 1:1 so as to enables the secondary to suck out the current from rails equal in
magnitude to that flows in primary

66
Fig 3.7.Booster transformer with return feeder

3.9. Neutral sectioning

Power generation and transmission systems of supply are three phase system. For traction it needs single
phase system. If all he traction loads are put on one phase alone, it will causes unbalancing in three phase
system. For this the adjacent substations tap different phases of three phases in order to achieve even
loading of the lines. For that it must have boundary of supply between two substations which have insulated
over lap. Therefore Momentary passing of pantograph under insulated overlap will cause short circuit
between two phases, thereby damaging the OHE equipments. In order to prevent bridging of two different
phases a small insulation called neutral section is provided. It is insulated from both sides and is not
connected to any source of supply. Its main function is to permit physically smooth and electrically
sparkless passage of pantograph from one section to and the other. Neutral sections are indicated in displays
for the drivers of an electric train to switch off before approaching neutral section and coast it to other zone.
For these warning boards are placed to draw the attention of the driver.

Fig 3.8.Neutral sectioning

67
3.10Traction Mechanics

2.1) Units and notations

In describing various quantities involved in the mechanics of train movement, only the latest SI system will
be used. Since SI system is an ‘absolute system’, only absolute units will be used while gravitational units
(used hitherto) will be discarded.

1. Mass: Its unit is kilogram (kg). Commonly used bigger units is tone (t),

Where 1 ton=1000 kg

2. Force: It is measured in Newton (N)

3. Work: Its unit is the same as that of energy.

4. Power: Its unit is watt (W) which equals 1 J/s. also Kilowatt (kW)

5. Distance: Its unit is meter. Other unit often used is kilometer (km).

6. Velocity: Its absolute unit is meter per second (m/s).

7. Acceleration: Its unit is meter/second2 (m/s2). Acceleration is given in km/h/s

3.10.1. Types of Railway Services

There are three types of passenger services which traction system has to cater for namely Urban Sub-urban
and Main line services. In urban and sub-urban service the distance between the stops are small. On main
line service distance between stations is long

1. City or Urban Service. In this case, there are frequent stops, the distance between stops being
nearly 1 km or less. Hence, high acceleration and retardation are essential to achieve moderately high
schedule speed between the stations.
2. Suburban Service. In this case, the distance between stops averages from 3 to 5 km over a distance
of 25 to 30 km from the city terminus. Here, also, high rates of acceleration and retardation are necessary.
3. Main Line Service. It involves operation over long routes where stops are infrequent. Here,
operating speed is high and accelerating and braking periods are relatively unimportant.
On goods traffic side also, there are three types of services (i) main-line freight service (ii) local or pick-up
freight service and (iii) shunting service

3.10.2. Speed Time Curve

It is the curve showing instantaneous speed of train in kilometers per hour along ordinate and time in
seconds along abscissa. Area in between the curve and abscissa gives the distance travelled during given
time interval. Slope at any point on the curve towards abscissa gives the acceleration of retardation at that
instant.

a) Typical Speed/Time Curve

Typical speed/time curve for electric trains operating on passenger services is shown in Fig. It may be
divided into the following five parts:

68
Fig 3.9.speed time curve

1. Constant Acceleration Period (0 to t1) Notching up period

It is also called notching-up or starting period because during this period, starting resistance of the motors is
gradually cut out so that the motor current (and hence, attractive effort) is maintained nearly constant which
produces constant acceleration alternatively called ‘rheostat acceleration’ or ‘acceleration while notching’.
To cut the starting resistance handle has to be moved from one notch and hence the name given to this
period. Attractive effort is defined as the force in newtons exerted by driving wheel on the rail to produce
movement. Sum of the attractive efforts exerted by all the driving wheels of a locomotive is called gross
attractive effort which is proportional to the combined torque exerted by the motors.

Motor current during notching up period fluctuates between certain maximum and minimum limits.
Therefore torque developed by the motor and attractive effort also fluctuates. Speed time curve therefore is
a straight line. Dotted speed time curve is obtained in case of series parallel starting

2. Acceleration on Speed Curve (t1 to t2)

This acceleration commences after the starting resistance has been all cut-out at point t1 and full supply
voltage has been applied to the motors. During this period, the motor current and torque de-crease as train
speed increases. Hence, acceleration gradually decreases till torque developed by motors exactly balances
that due to resistance to the train motion. When all the starting resistance has been cut out attractive effort
exerted by the motor is more than the train resistance. As speed increases train resistance increases very
much. This reduces the net attractive effort available for giving acceleration.

The speed of the train will continue to increase to a speed at which attractive effort is equal to the train
resistance. Train will then continue to run at this maximum speed.

3. Free running period (t2 to t3) period

During this period train runs at constant speed attained at the end of speed curve running. During this period
ie, (t2 to t3) the power supplied to the motor is full voltage and power drawn from the supply is also
constant.

4. Coasting (t3 to t4) period

Power to the motors is cut off at point t3 so that the train runs under its momentum, the speed gradually
falling due to friction, windage etc. (portion CD). During this period, retardation remains practically
constant. Coasting is desirable because it utilizes some of the kinetic energy of the train which would,
otherwise, be wasted during braking. Hence, it helps to reduce the energy consumption of the train. At the

69
end of free running period supply to motors is cut off and train is allowed to run under its own momentum.
Due to train resistance speed of the train gradually decreases.

5. Braking (t4 to t5) or retardation period

At point t4, brakes are applied and the train is brought to rest at point t5.It may be noted that coasting and
braking are governed by train resistance and allowable retardation respectively. At the end of coasting
period brakes are applied to bring the train to stop.

3.4.Speed/Time Curves for Different Services

Fig. 3.10(a) is representative of city service where relative values of acceleration and retardation are high in
order to achieve moderately high average speed between stops. Due to short distances between stops, there
is no possibility of free-running period though a short coasting period is included to save on energy
consumption.

In suburban services [Fig. (b)], again there is no free-running period but there is comparatively longer
coasting period because of longer distances between stops. In this case also, relatively high values of
acceleration and retardation are required in order to make the service as attractive as possible.

For main-line service [Fig. (c)], there are long periods of free-running at high speeds. The accelerating and
retardation periods are relatively unimportant.

Fig 3.10.speed time curve for a) main line b) urban c) suburban.

70
3.11. Simplified Speed time curve
In order to make actual speed time diagram amenable to calculation simplified speed time curves are
taken in such a way as to cause least error and at the same time calculations are made easy. OABC is
the actual speed time curve. The basis of constructing simplified speed time curves to keep both
acceleration and retardation values same and area under actual and simplifier curves also same. In
case of simplified trapezoidal speed time curve OABC speed curve running and coasting periods are
replaced by constant speed period. On the other hand in case of simplified quadrilateral speed time
curve OABC speed curve running and coasting periods are extended. Trapezoidal speed time curve
gives closer periods are extended. Trapezoidal speed-time curve gives closer approximation of the
conditions of main line service where long distance involved and quadrilateral speed time curve for
urban and suburban service.

Fig 3.11.Simplified Speed time curve

(i) Trapezoidal shapeOA1B1 Cof Fig. where speed-curve running and coasting periods of the actual
speed/time curve have been replaced by a constant-speed period.

(ii) Quadrilateral shapeOA2B2Cwhere the same two periods are replaced by the
extensions of initial constant acceleration and coasting periods.

It is found that trapezoidal diagram OA1B1C gives simpler relationships between the principal
quantities involved in train movement and also gives closer approximation of actual energy consumed
during main-line service on level track. On the other hand, quadrilateral diagram approximates more
closely to the actual conditions in city and suburban services.

71
a) Derivation of maximum speed from trapezoidal speed- time curve

Fig 3.12.trapezoidal speed- time curve


Considering the trapezoidal speed time curve in fig:
Let S= Distance between stops in km.
T= Actual time of run between stops in sec.
α = Acceleration in km per hour per sec. (kmphps)
β = Retardation in km per hour per sec.
Vm=Maximum speed in km per hour.
t1=Time for acceleration in sec = Vm/α
t3=Time for retardation in sec = Vm/β
t2= Time for free running in sec= T- (t1+t3) = T – (Vm/α +Vm/β)
the area of the trapezoidal gives the total distance of run in km.
Total distance = Area of trapezoid OABC
S = Area of triangle OAD + Area of rectangle ABED + Area of triangle BCE
= + Vm+ Vm += Vm

= [ t1 +t2+ t3]

= [ t1 +t3 )+t2]

= [ t1 +t3 )+T- (t1 + t3) ]

= [ (t1 +t3 )( +T]

= [ (t1 +t3 )]

= [ ( + ]

S = [ Vm ( + ]

3600 S = TVm - Vm2 ( +

2
( + Vm -TVm+ 3600 S =0

72
This is a quadratic equation

Put ( + =K

Then the equation becomes

KVm2 –T Vm +3600 S = 0

Solving the equation , we get

The positive sign gives very much high value of Vm which is not possible in practice, hence
negative sign is adopted.

Therefore

Average speed and schedule speed

While considering train movement, the following three speeds are of importance :

1. Crest Speed=It is the maximum speed (Vm) attained by a train during the run

2. Average speed =

3. Schedule speed =

3.12. Factor affecting schedule speed

Following are the factors which affect the schedule speed of a train engaged in a given service.

(i)Value of α and β (ii) Duration of stop

3.13. Tractive Effort.

Tractive effort is the force developed by the traction unit at the wheel rims for moving the traction
unit and its train. Thus the tractive effort by the force required to move the traction unit. Tractive
effort exerted by the traction unit has to perform the following functions

 To give necessary linear and angular acceleration to the train mass


 To overcome the gravity component of the weight of the train
 To overcome the wind and frictional resistance of the train
 To overcome curve resistance

73
1. Tractive effort for acceleration:

Force is required to give linear acceleration to the train and is given by ( Fa )


Let M is the dead mass or stationary mass of the train in tones.

Dead mass of train = M tones

Since 1 tonne =1000kg

Acceleration = α km/hr/sec2

( Fa ) = = 277.8 Wα Newtons or m/sec2

When the speed of the train is being changed it behaves as a mass greater than its dead weight. This is
due to angular speed variation of its rotating parts. If linear acceleration is f meter/sec2 angular
acceleration of rotating parts having radius of gyration r meters’ will be f/r radians/sec2.

Generally the effective mass is 10% more than the dead mass.

ie, Me=1.1 M

Let the effective mass of the rain =Me ton =1000Mekg

Therefore Force required for acceleration = Mass x acceleration

ie, Fa= Me x a

=1000 Me x α 1000/3600

Fa = 277.8. Me α newtons.

2. Tractive effort to overcome the train resistance:

Train resistance consists of all the forces which oppose the motion of the train on level track. This
force can be classified as those forces which are internal to the rolling stock such as friction at
journals axis guides bogie pivots buffers and those forces which are external to the rolling stock such
as friction between wheels and rails. Track resistance depends upon the strength of the track and
nature of the ballets. Wind resistance due to the length of train is due to air friction on sides and to
underside of the train. This is sometimes termed as skin friction.

Therefore tractive effort to overcome the train resistance

Fr =M x r Newton’s

Where M = mass of train in tones

r = train resistance in newtons/tone

Now if I is the moment of insert of rotating masses and F the force in newtons applied at the rim the
wheel then torque applied (F,r)will be given by

74
Magnitude of force as per equation will be in addition to the forced required to give linear
acceleration and equivalent additional mass of rotating masses of rotating masses is I/r2Km.This
additional mass is best expressed as a percentage of the dead weight of train the value of effective
weight of the train We which takes in to account not only motion of translation of train but also the
motion of rotation of wheels axis armatures of motors and gears Equation now becomes

3. Tractive effort required to balance the gravitational pull (Fg)

When train is on an up-gradient gravity component of dead weight of train parallel to the track will be
responsible for the train to come down In order to prevent this tractive effort has to be applied in
upwards direction whose magnitude is give by

Fg= Mg sinθ tonne m/sec2

= 1000 Mg sinθ kg m/sec2ie,(1 tonne=1000kg)

=1000Mg sinθ Newton

Where g is the acceleration due to gravity

= 9.81 m/sec2

θ is the angle of scope

Fg =1000Mx9.81 sinθ Newton--------------(1)

In railway practice gradient is expressed in terms of rise or fall in a track distance of 1000 meters and
is denoted by letter G% Location of gradient has important effort on the over loading that can be
permitted on the traction motors. For instance if does not create any problem as momentum of the
train takes it up the steep gradient. On the other hand if ruling gradient happens to be in the middle of
a rising gradient the length of gradient becomes very important in determining the temperature

Gradient G = = x 100

G = 100 Sin θ

Sin θ = G/ 100----------------------(2)

75
Putting the value of Sin θ in equation (1)

Fg =1000Mx9.81 x Newton

Fg= +98.1MG Newton

Positive sign is to be used for up gradation and negative sign for down gradient

Therefore, total tractive effort Ft = Fa +Fr +Fg

= 277.8. Meα +Mr++98.1MG

3.9. Power required:

a)Power P= Rate of work =

=tractive effort x speed =Ft x V

Where V is in km/hr = m/sec

Therefore P = Ft x N-m/sec or watts.

b) Specific Energy output

It is the energy given in watt hours per ton of train. The energy output of driving wheels. When this is
divided by mass of transmission gear and distance, we will get specific energy output.

Specific energy output=

Where are

E =Ea+Er+Eg

E = Total energy output of driving axis

Ea = Energy output of driving axis to acceleration the train

Er = Energy output of driving axis to overcome friction

Eg = Energy output of driving axis to overcome gradient

76
c) Specific Energy Consumption

It is the energy consumed in watt hours per ton of train. The specific energy output of driving wheels,
when this is divided by overall efficiency of transmission gear and motor we will get specific energy
consumption

Specific energy consumption==

d) Factors Affective Specific energy Consumption:

The factors affecting specific energy consumption as follows

a. Distance between stops


b. Acceleration and retardation
c. Gradient
d. Train resistance
e. Type of train equipment

3.14. TRACTION MOTOR AND CONTROL:

a) Desirable characteristics of traction motors

i) Electrical characteristics

1. The motor should have high starting torque

2. The speed of the motor should fall with the increases in load.

3. Speed control of the motor should be simple.

4. It should be possible to employ dynamic or regenerative braking.

5. The motor must able to withstand sudden voltage fluctuations

6. The motor should have high efficiency.

7. The motor should be suitable for series parallel control.

ii) Mechanical characteristics

1. A traction motor must be robust and capable to withstand continuous vibrations.

2. The motor must be small in over all dimensions.

3. The motor should have minimum possible weight.

4. The motor should be totally enclosed type to provide protection against different types of
weather and dirt, dust, water, mud…

77
b) Motors used for traction purpose.

The following motors are used for traction purposes:

1. D.C. Series motor

2. A.C.Series motor

3. Repulsion motors.

4. Three phase induction motor.

5. Linear induction motor.

3.15. Control of DC Traction motors

The magnitude of the current taken by a dc motor is given by equation

I =

At starting the magnitude of the back emf Eb is zero obviously if the motor is switched on directly to
the supply it will take very heavy current because the motor resistance is very small Excessive current
would cause serve mechanical damage to the equipment and therefore its magnitude has to be
restricted by adopting suitable measures. This is achieved by either applying reduced voltage to the
motor or by artificially increasing the resistance in the motor circuit. In ac traction practice it is
usually the first method which is adopted.

It is normal practice except in the case of small train car controllers to design the resistance as capable
of carting only starting currents and is not in a position to carry motor currents continuously. The
motor can therefore have only one speed characteristic besides this disadvantage considerable amount
of energy is wasted in the starting resistances. Both of these disadvantages are overcome in series
parallel and buck and boost control of traction motors described hereafter

3.16.Methods of starting D.C. traction motors

1. Plain Rheostatic starting

2. Series – parallel starting

3. Metadyne control

78
1. Plain Rheostatic starting (3.13)

In this method, the voltage across the motor armature is increased gradually from zero o full voltage.
This is obtained by connecting an external series resistance as shown in fig. This external resistance
helps to limit the starting current and suitable of the DC motors.

When the supply is switched ON, the back emf is zero. As the motor accelerates and speed increases,
motor current will go on reducing with the development of back emf in the motor armature. When
certain values of minimum motor current are reached, a portion of external resistance is cut out. As a
result of this motor current again reaches its maximum value.

Energy saving with rheostatic starting

Let, I= current
V= supply voltage
T = starting period in sec.
Energy last in external resistance= Average voltage drop at external resistance x current x time

= x I xT

= watt-sec

Energy utilized by the motor = average voltage drop across motor x time

= x I xT

= watt-sec

Therefore energy drawn from drum supply= energy lost in resistance +energy utilized in motor

= + = VIT watt-sec

79
Total energy input = VIT watt-sec

Starting efficiency = x 100%

Starting efficiency = 50%

2. Series Parallel Control (fig 3.14)

It is usual to have at a time more than one traction motor. In that case it is economical to have
combined rheostatic and series parallel control of traction motors. Accordingly two traction motors
are connected in series and supply to them is given through the starting resistance in series which is
progressively cut out until only two motors remain in series when the motors are left running in this
position voltage across each will be nearly half of the supply voltage and motors will be running
nearly at half the full speed. For full speed motors are disconnected and then reconnected in parallel
again supplied through starting resistance. This resistance is then progressively cut out leaving motors
in parallel running condition.

Both series motors are connected in series through full starting resistance across supply. Starting
resistance is gradually cut out step by step till both series motors are in series across supply it should
be noted here that the starting resistance always divided into two separate sections each connected
motor. This makes it possible to employ same resistance in both series and parallel for either
connection. Both the motors are put in parallel along with their respective external resistances across
supply

External resistance is gradually cut out till both the motors are left in parallel across supply. Various
steps involved in between connections shown in are separately shown. In fig 3.15

80
Fig When motors are in series across supply as voltage across each motor is half the supply voltage
and will be running nearly at half the speed when they are put in parallel across supply as

Energy saving with series parallel control

Let, I= current

V= supply voltage

T = starting period in sec.

When the motors are in series, the voltage raises from 0 to V/2 volts. Let the time
required be half of total accelerating period ie, T/2 sec.

Energy utilized by each motor= Average voltage x current x time

= x I xT/2

= watt-sec

81
Energy utilized by two motor = x 2 watt-sec = watt-sec

Energy drawn from the line during this period= V x I x T/2

= watt-sec

When the connection is changed from series to parallel the voltage is increased from V/2 to V volts.

Energy utilized by two motor= 2 x Average voltage x current x time

=2x x I xT/2 = watt-sec

The current drawn from the line during this period = 2 xI

Energy drawn by the two motors =Vx2IxT/2

= VIT watt-sec

Therefore ,total energy utilized during both series and parallel connections

= + = VIT watt-sec

Total energy drawn during series and parallel connections = + VIT

= watt-sec

Starting efficiency = x 100%

Starting efficiency = %

Therefore the starting efficiency is increased from 50% to 66.67% with series parallel method. By
adopting four motors, starting efficiency is increased up to 72.72% and higher number of motors the
efficiency goes up.

Advantages of Series Parallel Starting

 It has higher efficiency than plain rheostatic method of starting as proved above
 We get more than one economical speeds which are possible in plain rheostatic method only wasting
energy in the rheostat.
 Due to low energy loss in the starting resistances they are not of cumbersome size
 Connecting the motor to supply without taking excessive current at starting
 Providing smooth acceleration without sudden shock to avoid damage to couplings
 Adjusting the speed according to the type of services and route conditions
 In this chapter we will take up various control method for motors supplied from straight dc supply
rectified ac supply and pure ac supply

82
3. Metadyne control

Fig 3.16.Metadyne control

Metadyne converter is a machine which takes power at constant voltage and variable current and
delivers at constant current and variable voltage. The main advantages of this is that the loss is much,
lower than resistance starting method. Since the current throughout the starting period is maintained
constant, uniform tractive effort is produced and so jerks are avoided.

This type of control gives very smooth drive and high coefficient of adhesion. The metadyne consists
of a d.c. armature wound for two poles, and provided with two pairs of brushes and a 4 –pole field
magnet as shown in fig.

One pair of brushes A,B is connected across a constant voltage d.c. supply whereas the other pair
C,D is connected to load ie series traction motor. The metadyne converts constant voltage supply in to
a constant current, variable voltage supply for feeding the load. The machine acts as a motor as far as
brushes AB are concerned and as a generator as far as brushes CD are concerned. With metadyne
converter, a regenerative braking can be obtained by reversing the field of traction motor and also the
magnitude of regenerative braking can be controlled by controlling the magnitude of reverse
excitation.

2.13. Methods of series parallel connection

Series parallel method of starting can be achieved by using the following two methods.

83
1. Shunt Transition fig 3.17

According to this method transmission from connections shown is carried out in four steps as shown
fig.a,b,c,d.

1) In first step the motors run with full resistance in series as in fig a and this is known as First Series
After whole of the external resistance has been cut out as shown in fig b, now motors are now in
series without resistance. This is known as Full Series.

2) Second step is to short circuit one motor as in fig c. This is known as First Transition

3) Third step is open one end of the short circuit motor as shown fig d. This is known as Second
Transition and some of the resistance is connected and also known as First Parallel.

4) Fourth step is to connect this open end of the motor with corresponding terminal of the other motor.
This is shown fig e and the external resistance is gradually reduced and now the motor runs at Full
Parallel. It will be observed that during shunt transition steps from 1 to 4 one motor is actually short
circuited and then disconnected from supply and afterwards reconnected in parallel. This therefore
results in the loss of tractive effort during this period till motor is reconnected in parallel.

84
2.BridgeTransitionfig3.18

Main advantage of bridge transition method is that none of the motors is disconnected in the process
of transition from series connection to parallel connection.

Various steps involved are:

In the first step individual resistances are shorted out as shown fig a. which is equivalent to motors are
now in First Series

In the second step bridge link is so moved that motors are put in series by reducing the resistances and
now the motor is at Full Series. As in fig b.

In the third step during transition a portion of starting resistance is connected in parallel with each
motor and formed as bridges as in fig.c.

In the fourth step bridge link is removed. Now motors are in parallel with individual resistance
inserted in each motor as shown in fig d. now the motors are in First Parallel

Finally the resistance is reduced and now the motor is in Full Parallel as in fig e.

85
Bridge transition method is very much suitable for operation under predetermined conditions of
current and load such as those obtained in multiple unit trains

2.14 .A. Multiple unit control

Fig 3.19.Multiple unit control

The coaches where electric motors are installed are known as motor coaches. For city and suburban
services, It is usual to use motor coaches. Multiple unit trains are better suited for high speed running.
Main advantage of this is the flexibility of operation.

Multiple unit train comprises the number of units. Each unit consists of a motor coach and number of
trailing coaches for passengers. Depending upon the traffic requirement, a suitable number of motor
and trailer coaches are added.

Each motor coach has two or four motors. It is possible to control the operation of all the motors in
train from single point. This controlling system is known as multiple unit control.

The motor coaches of each unit consists of group of traction motor, series parallel controller, reverser,
accelerating relay, motor generator set, coupler, over current relay, cutout switch, fuse…

The complete circuit of each unit connected in parallel with the help of coupling cable as shown in
fig. is known as master controller. If the system has more than one controller, it is necessary to have
an interlocking system.

If we considered the control point is unit no.1. ie, master controller, and the train is to be started from
this unit. The contacts 0 and 1 of this controller unit are closed which will close down the contacts 0
and 1 of other units. At the same time the relay R1 of all the units are closed and full starting resistance
include with the motor. By this way traction motors in all units are started using multiple unit control.
Next step the closing contacts 0 and 2 will energies the relay R2 of all units. This reduces the starting
resistance. Similarly in next step R3 energies and cut down the total resistance in all units. Likewise
starting, stopping and reversing operations are carried out by a single master unit control unit.

86
2.14. B. Drum Controller Employing Shunt Transition (fig 3.20)

Drum controller consists of rectangular interconnected but insulated strips carried on the cylinder.
When the drum is moved through certain angles these strips make contact with appropriate contacts
called fingers to which are connected rheostatic resistances, motor and supply terminals.

One such drum controller employing shunt transition from series to parallel connections of motors is
shown in fig. For convenience sake cylindrical surface of drum controller is opened and layouts of
segments shown by thick rectangular strips fingers are shown by vertical row of dots.

Vertical chain dotted lines show the operating positions called notches and coincide with the centered
line of the fingers.

87
Fig 3.21.shunt transition.

a) On first notch fingers a and b are connected together and so also h and i. This puts the motors in
First Series with full resistance assign fig a.

b) With controller moved from notch 1 to 4 external resistance is gradually cut out till at notch 4 we
get motors connected at Full series. In fig b.

c)For various operations of shunt transition taking place in between notch 4 and 5 various sub notch
position are indicated.

1. At sub notch position strip w leaves contact of finger f this inserts resistance between fingers c and
f. Therefore notch 4a position corresponds to fig c.

2.At 4 b position while segments y have contact with finger h and i, segments z also establish contact
with fingers j and k. This short circuits fingers h and k thereby short circuiting motor 2.This short
position is corresponding to fig d.

3. At sub notch position 4c segments Y loose contact with fingers h and i.

d) At notch 5 segment x establishes contact with fingers g and h. This position is corresponding to fig
.f. and now the position is First parallel

e) At this positions 6 and 7 gradually reduces the resistance till notch position 8 corresponds to fig.g
and now the position is Full parallel

88
In reverse drum controller direction of motor is changed by changing the direction of current flow
through armature.

2.14.C .Contactor Type Bridge Transition Controller fig 3.22.

Power circuit of two motor traction unit using bridge transition is shown sequence of contactor
operation at various notches. This unit consists of

i) Overload relay OLR is connected in series with each traction motor circuit

ii) Reverser is used to reverse the connections of the traction motor field for changing the direction of
rotation

iii) Motor cut out switches and links are used to isolate any of the defective traction motor and
provide a bypass to complete the circuit

iv) Auxiliary contacts are provided in addition to main contacts on overload relay reverser and motor
cut out whose function is explained as follows

The connection diagram is having motors M1 and M2 are connected in series with three switches L1,
L2 and D. Motors M3 and M4 is connected with switches L3 , L4 and C.

89
Bridging contacts B1 and B2 have full line voltage across them, when the motors are in parallel.
Resistance X is used to protect the system.

In the starting position line switches L3, L4 and bridge contact B close and D, C, L3, L4 are open.
Now all the motors are in first series as the connections are:

1. First series through- L1, L2, M1, M2, STARTINGRESISTANCE,

CONTACT B, STARTING RESISTANCE, M3and M4.

Now contactor R operates and cut down the resistance in step and now current flow through

2. Full series through - L1, L2, M1, M2, R, CONTACT B, R, M3 and M4.

Now contacts B1, B2 closes and B opens, but still the motors operates in series

Current flow through – L1, L2, M1, M2, B1, B2, M3, M4.

Now the contacts R open, C, D closes, B1, B2 open

3. First parallel through --L1, L2, M1, M2, STARTINGRESISTANCE, D and

L3, L4, C, STARTING RESISTANCE, M3 and M4.

Now contactor R operates and cut down the resistance in step and now current flow through

4. Full parallel through --L1, L2, M1, M2, R,D and

L3, L4, C, R, M3 and M4.

Auxiliary contacts on motor cut out switch confine the circuit operation to the series connections
when one motor is isolated and short circuited.

2.15. Braking in Traction

Both electrical and mechanical braking is used. Mechanical braking provides holding torque.
Electric Braking reduces wear on mechanical brakes, provides higher retardation, thus bringing a
vehicle quickly to rest. Different types of electrical braking used in traction are Plugging, Rheostatic,
Regenerative braking..

Regenerative Braking with D.C. Motors

In order to achieve the regenerative braking, it is essential that (i) the voltage generated by the
machine should exceed the supply voltage and (ii) the voltage should be kept at this value,
irrespective of machine speed.

During electrical regenerative braking, traction motors are made to work as generators, utilizing
kinetic energy of the moving train to run the generators. Electrical energy is fed back to supply line.

90
Fig.3.23. (a) shows the case of 4 series motors connected in parallel during normal running i.e.
motoring.

One method of connection during regenerative braking is to arrange the machines as shunt
machines, with series fields of 3 machines connected across the supply in series with suitable
resistance. One of the field winding is still kept in series across the 4 parallel armatures as shown in
figure (b).

The machine acts as a compound generator. (With slight differential compounding) Such an
arrangement is quiet stable; any change in line voltage produces a change in excitation which
produces corresponding change in e.m.f. of motors, so that inherent compensation is provided e.g. let
the line voltage tends to increase beyond the e.m.f. of generators. The increased voltage across the
shunt circuit increases the excitation thereby increasing the generated voltage. Vice-versa is also true.
The arrangement is therefore self compensating

D.C. series motor can’t be used for regenerative braking without modification for obvious reasons.
During regeneration current through armature reverses; and excitation has to be maintained. Hence
field connection must be reversed.

3.17.MAGNETIC LEVITATION(MEGLEV)

In levitation system, ordinary electromagnets are used .These magnets produce an attractive
force and levitate the vehicle i.e., to rise and float the vehicle in the air with no physical support. The
electromagnets are attached to the car. These magnets are placed such that they are facing the
underside of the rail as shown in fig.3.26.They produce an attractive force and levitate the car. The
attractive force is controlled by a gap sensor. The gap sensor measures the distance between the rails
and electromagnets. A control circuit continuously regulates the gap at a fixed distance of about
8mm.If the gap increases beyond 8mm,the current to the electromagnet is increased, to create more
attraction(i.e., Now the gap is reduced).If the gap become less than 8mm,the current is decreased, to
create less attraction(i.e., Now the gap is increased).

The levitation magnets are ‘U’ shaped and the rails are inverted ‘U’ shaped as shown in fig.
In this system the electromagnetic attractive forces levitates and guide the car.

In this system linear induction motor is used. The linear induction motor is just like ordinary
induction motor, but it has been split open and flattened. The primary side coils of the motor are
attached to the car body. The secondary side reaction plates are installed along the guide way of the
rail as shown in fig. The secondary plate is made of aluminum or copper plate.

91
Fig 3.24.MAGNETIC LEVITATION (MEGLEV)

Advantages

1. The vehicle is designed so that it interlocks with the guide way. So there is no risk of
derailment.

2. When the vehicle is running, there is no physical contact between the carriages and guide way
which minimize the noise and vibration.

3. There are less moving and rolling parts. So wear and tearis less. Hence low maintenance is
required.

SUSPENSION SYSTEMS

Primary and secondary suspension system

In suspension arrangement the locomotive (train engine) is carried by two bogies. The
bogies are coupled by two or more axles. As the locomotive moves on the track, shocks are delivered
to the wheels and axles due to irregular tracks. The purpose of suspension arrangement is to minimize
the transmission of these shocks to the locomotive body with the help of springs and dampers. The set
of springs and dampers are interposed in between axles and bogie. This arrangement is called primary
suspension.

Generally up to 80 Kmph speed, railway vehicles do not produce any special vibration. At
higher speeds vibration becomes more. Therefore for high speed vehicles, a second set of spring of

92
low stiffness is provided in between the bogie and the body. These set of springing arrangement is
called secondary suspension.

Review questions
Part A& B
1. Mention the methods of Feeding power to locomotive?
2. Define Average speed of Electric Train?
3. Mention the methods of Starting DC Traction motors?
4. Write the Frequency Adopted in single phase low frequency AC system of Track Electrification?
5. What is the purpose of Providing Neutral section in Track Electrification?
6. What are the different types of Electrical transmission in Diesel electric Traction?
7. Name the Motors used for traction purpose?
8. State the types of Traction Systems?
9. Define Co-effect ion of adhesion.
10. Define Average Speed.
11. What is mean by transition in Series-Parallel control connection?
12. List the advantages and Disadvantages of Diesel Electric traction System?
13. What are the advantages of electric traction?
14. What is the purpose of using Catenary and Droppers in electrical traction?
15. What is Neutral sectioning?
16. List the factors affecting schedule Speed.
17. What are the necessity of Booster Transformer?
18. List the desired Electrical and Mechanical Characteristics of traction Motors.
19. Compare overhead system and conductor Rail system.
20. Define Tractive Effort.
21. State the types of Traction Services.
22. Explain the operation of pantographs collectors.
23. Explain the over head equipments.
24. Define specific energy consumption and energy output.
25. Explain the regenerative braking in traction?
26. What are the types of braking methods?
27. What is primary and secondary suspension system in traction?
PART C
1. Explain different current collectors used in electric traction?
2. Explain contactor type Bridge Transition controller?
3. Write short notes on Booster transformer connection in Electric Traction and Neutral sectioning.
4. Draw the Typical Speed time Curve and explain each Constituent of it?
5. Derive the basic principles for the crest speed using Trapezoidal speed time curve. State all your
assumption clearly with relevant units.
6. Draw the layout diagram of typical 25KV traction substation and explain the same.
7. Derive the tractive effort of a traction system.
8. Explain in detail different starting methods of traction motors
9. Explain in detail plain rheostatic control in detail
10. Explain in detail series parallel method of starting of traction motors
11. Explain in detail shunt and bridge Transition controller?
12. Explain in detail multiple unit controller?
13. Explain briefly the Magnetic Levitation.

93
UNIT IV
ILLUMINATION
4.1. INTRODUCTION
Illumination as a body is gradually heated above room temperature; it begins to radiate
energy in the surrounding medium in the form of electromagnetic waves of various wavelengths. The
nature of this radiant energy depends on the temperature of the hot body.

The usual method of producing artificial light consists in raising a solid body or vapour to
incandescence by applying heat to it. It is found that as body is gradually heated above room
temperature, it begins to radiate energy in the surrounding medium in the form of electromagnetic
waves of various wavelengths. The nature of this radiant energy depends on the temperature of the hot
body. Thus, when the temperature is low, the radiated energy is in the form of heat waves only, but
when a certain temperature is reached, light waves are also radiated out in addition to heat waves and
the body becomes luminous. Further increase in the temperature produces an increase in the amount
of both kinds of radiations but the cplour of light or visual radiations change from bright red to
orange, to yellow and finally, if the temperature is high enough, to white. As the temperature is
increased, the wavelength of visible radiation goes on becoming shorter. It should be noted that heat
waves are identical to light waves except that they are of longer wavelength and hence produce no
impression on retina. Obviously, from the point of view of light emission, heat energy represents
wasted energy.
Radiant efficiency of the luminous source is defined as the ratio of “energy radiated in the
form of light” to “total energy radiated out of the hot body” and it depends on the temperature of the
source. As the temperature is increased beyond that at which the light waves were first given off, the
Radiant efficiency increases, because the light energy will increase in greater proportion than the total
radiated energy. When emitted light becomes white, i.e. it includes all the visible wavelengths, from
extreme red to extreme violate, then a further increase in temperature produces radiations which are of
wavelengths smaller than that of violate radiations. Such radiations are invisible and are known as
ultra-violate radiations. It is found that maximum radiant efficiency would occur at about 62000 C and
even then the value of this maximum efficiency would be 20%. Since this temperature is far above the
highest that has yet been obtained in practice, it is obvious that the actual efficiency of all artificial
sources of light i. e. those depending on temperature incandescence, is low.

Light is thus a part of radiant energy that propagates as a wave motion. Approx. velocity
being 3x108 m/sec. The wavelengths which can produce sensation of sight have a range from 4x10-5
cm to 7.5x10-5 cm. For expressing wavelength of light, another unit called Angstrom Unit (1 A.U. =
10-8 cm= 10-10 m) is used. Thus the visible radiation lies between 4000 AU to 7500 AU. Typically a
wavelength of 6000 AU produce yellow cplour and 4000 AU produces violate cplour.

4.2. IMPORTANT TERMS USED IN ILLUMINATION

i)PLANE ANGLE

A plane angle, θ, made up of the lines from two points meeting at a vertex, is defined by the
arc length of a circle subtended by the lines and by the radius of that circle, as shown below. The
dimensionless unit of plane angle is the radian, with 2π radians in a full circle.

94
ii)SOLID ANGLE

A solid angle, ω, made up of all the lines from a closed curve meeting at a vertex, is defined
by the surface area of a sphere subtended by the lines and by the radius of that sphere, as shown
below. The dimensionless unit of solid angle is the steradian, with 4π steradians in a full sphere.

iii) LUMINOUS FLUX:

Luminous flux is the rate of energy radiation in the form of light waves. The unit is lumen.
It is thus the rate of energy radiation in the form of light. It is energy per second (and hence
comparable to Power).
Approximate relation between lumen and electric unit of power i.e. watt is given as:
1 lumen=0.0016 watt (approx) or 1 watt=625 lumen (approx)

iv) LUMINOUS INTENSITY:

Luminous intensity in a given direction is the quotient of the luminous flux emitted by a
source (or by an element of a source), in an infinitesimal cone containing the given direction by the
solid angle of that cone. Hence it is the luminous flux / unit solid angle.

v) LUMINOUS EFFICACY

Efficacy is the ratio of light output from a lamp to the electric power it consumes and is
measured in lumens per watt (LPW).

vi) CANDLEPOWER:

Candlepower is the capacity of a source to radiate light and is equal to the number of lumens
emitted in a unit solid angle by a source of light in a direction. Its unit is Candela (cd) or lumens
per steradian.

95
A source of one candela emits one lumen per steradian. Hence total flux emitted by it all-
round is 4πx1=4π lumen.

vii) LUMEN:

Lumen is the unit of luminous flux. It represents the flux emitted in unit solid angle of one
steradian by a point source having a uniform intensity of one candela. Thus a uniform point source of
one candle power emits 4π lumens.
Lumens = Candle power x Solid angle.
viii) ILLUMINATION:
The luminous flux reaching a surface, per unit area of that surface. One lumen per square
meter is termed as one lux. Also
Illumination = Flux / Area = Lumens / Area= (Candle power x Solid angle) / Area

ix) MEAN HORIZONTAL CANDLE POWER (MHCP):


It is the mean of the candle powers in all directions in the horizontal plane containing the
source of light.
x) MEAN SPHERICAL CANDLE POWER (MSCP):
Generally, the luminous intensity or candle power of a source is different in different
directions. The average candle-power of a source is the average value of its candle power in all the
directions. Obviously, it is given by flux (in lumen) emitted in all directions in all planes divided by
4π. This average candle-power is also known as mean spherical candle-power (MSCP).

xi) MEAN SEMI-SPHERICAL CANDLE POWER (MHSCP):

It is the mean or average of the candle powers in all directions below the horizontal.

It is given by the total flux emitted in a hemisphere (usually the lower one) divided by the solid angle
subtended at the point source by the hemisphere.

xii) REDUCTION FACTOR

The ratio of the mean spherical luminous intensity of a light source to its mean horizontal
luminousintensity.

xiii) LUMINANCE

Luminance is the luminous intensity in a given direction of an element of a surface, per unit
projected area of that surface.

96
xiv) GLARE
Glare may be defined as the brightness within the field of vision of such a character as to
cause annoyance, discomfort, interference with vision or eye fatigue.
xv) LIGHT EFFICIENCY
The ratio of total luminous flux over total power input, expressed in lumens per watt.
For ex: An electric lamp.
Xvi )SPACE HEIGHT RATIO
Spacing Height Ratio is defined as the ratio of the distance between adjacent luminaries
(center to center) to their height above the working plane.
SHR (Nominal) = (1/Hm) x (Square root (Area/N))

Where Hm is mounting height, N is number of luminaries.

xvii) WASTE-LIGHT FACTOR


A factor used in the design of floodlighting installations to allow for the light which, although
emitted along the beam from the projector, does not fall on the area to be illuminated.
xviii)DEPRECIATIONFACTOR
Depreciation factor is merely the inverse of the maintenance factor and is defined as the ratio
of initial meter-candles to the ultimate maintained meter-candles on the working plane. It is always
more than unity.
xiv) UTILIZATION FACTOR
Utilization factor or coefficient of utilization is defined as the ratio of total lumens reaching
the working plane to the total lumens given out by the lamp.
Xv) ABSORPTION FACTOR
The ratio of the total absorbed radiant or luminous flux to the incident flux is called
absorptance (formerly also absorption factor).
Xvi) REFLECTION FACTOR
A measure of the ability of a surface to reflect light or other electromagnetic radiation, equal
to the ratio of the reflected flux to the incident flux.

4.3.REQUIREMENT OF GOOD LIGHTING SYSTEM:

1. Illuminating source should have sufficient light.

2. It should not strike the eyes.

3. It should have suitable shades and reflectors.

4. It should be installed at such a place so as to give uniform light.

97
4.4. LAWS OF ILLUMINATION

A) COSINE LAW:

The illumination received on a surface is proportional to the cosine of the angle between the
direction of the incident light rays and the normal to the surface at the point of incidence. This is
mainly due to the reduction of the projected area as the angle of incidence increases. Thus

Eh= En cos θ (I cos θ) / D2

Where

Eh = illumination on a horizontal plane,


En = illumination due to light normally incident,
θ = the angle of incidence,
D = distance from the source.

B) INVERSE SQUARE LAW:

The illumination upon a surface varies inversely as the square of the distance of the surface
from the source. Thus if the illumination at a surface one meter from the source is X units, then the
illumination at 2 meters will be X/4 at 3 meters will be X/9 and so on.

Strictly the inverse square law operates only when the light rays are from a point source and
are incident normally upon the surface.

Thus illumination in lamberts/metre2 on a normal place= Candle power / (Distance in meters )2

4.5. FACTORS CONSIDER WHILE DESIGNING GOOD LIGHTING SYSTEM

•Look good!
•Provide the proper amount of light in every room.
•Be built and constructed within budget, code, and other constraints.
•Be environmentally responsible.
•Respond to the Architecture and Interior Design
•Produce good cplour
•Achieve the desired moods of each space
•Be able to control the lights.

4.6. SOURCES OF LIGHT


The lighting industry makes millions of electric light sources, called lamps. Those used for
providing illumination can be divided into three general classes:

98
 Incandescent,
 Discharge,
 Solid-state lamps.
 Incandescent lamps produce light by heating a filament until it glows.
 Discharge lamps produce light by ionizing a gas through electric discharge inside the lamp.
 Solid-state lamps use a phenomenon called electroluminescence to convert electrical energy
directly to light.
In addition to manufactured light sources, daylight — sunlight received on the Earth, either directly
from the sun, scattered and reflected by the atmosphere, or reflected by the moon — provides
illumination. The prime characteristic of daylight is its variability. Daylight varies in magnitude,
spectral content, and distribution with different meteorological conditions, at different times of the
day and year, and at different latitudes. The illuminances on the Earth’s surface produced by daylight
can cover a large range, from 150,000 lx on a sunny summer’s day to 1000 lx on a heavily overcast
day in winter. The spectral composition of daylight also varies with the nature of the atmosphere and
the path length through it.

4.7. Lighting Schemes


Different lighting schemes may be classified as
(i) Direct lighting
(ii) Indirect lighting and
(iii) Semi-direct lighting
(iv) Semi-indirect lighting and
(v) General diffusing systems.
(i) Direct Lighting
As the name indicates, in the form of lighting, the light from the source falls directly
on the object or the surface to be illuminated. With the help of shades and globes and reflectors of
various types as discussed, most of the light is directed in the lower hemisphere and also the brilliant
source of light is kept out of the direct line of vision. Direct illumination by lamps in suitable
reflectors can be supplemented by standard or bracket lamps on desk or by additional pendant fittings
over counters. The fundamental point worth remembering is planning any lighting installation is that

99
sufficient and sufficiently uniform lighting is to be provided at the working or reading plane. For this
purpose, lamps of suitable size have to be so located and furnished with such fittings as to give correct
degree and distribution of illumination at the required place. Moreover, it is important to keep the
lamps and fittings clean otherwise the decrease in effective illumination due to dirty bulbs or
reflectors may amount to 15 to 25% in offices and domestic lighting and more in industrial areas as a
result of a few weeks neglect. Direct lighting, though most efficient, is liable to cause glare and hard
shadows.

(ii) Indirect Lighting


In this form of lighting, light does not reach the surface directly from the source but
indirectly by diffuse reflection. The lamps are either placed behind a cornice or in suspended opaque
bowls. In both cases, a silvered reflector which is corrugated for eliminating striations is placed
beneath the lamp. In this way, maximum light is thrown upwards on the ceiling from which it is
distributed all over the room by diffuse reflection. Even gradation of light on the ceiling is secured by
careful adjustment of the position and the number of lamps. In the cornice and bowl system of
lighting, bowl fittings are generally suspended about three-fourths the height of the room and in the
case of cornice lighting, a frieze of curved profile aids in throwing the light out into the room to be
illuminated. Since in indirect lighting whole of the light on the working plane is received by diffuse
reflection, it is important to keep the fittings clean. One of the main characteristics of indirect lighting
is that it provides shadow less illumination which is very useful for drawing offices, composing rooms
and in workshops especially where large machines and other obstructions would cast troublesome
shadows if direct lighting were used. However, many people find purely indirect lighting flat and
monotonous and even depressive. Most of the users demand 50 to 100% more light at their working
plane by indirect lighting than with direct lighting. However, for appreciating relief, a certain
proportion of direct lighting is essential.

(iii) Semi-direct System

100
This system utilizes luminaries which send most of the light downwards directly on
the working plane but a considerable amount reaches the ceilings and walls also The division is
usually 30% upwards and 45% downwards. Such a system is best suited to rooms with high ceilings
where a high level of uniformly-distributed illumination is desirable. Glare in such units is avoided by
using diffusing globes which not only improve the brightness towards the eye level but improve the
efficiency of the system with reference to the working plane.

(iv) Semi-indirect Lighting


In this system which is, in fact, a compromise between the first two systems, the light
is partly received by diffuse reflection and partly direct from the source . Such a system, therefore,
eliminates the objections of indirect lighting mentioned above. Instead of using opaque bowls with
reflectors, translucent bowls without reflector are used. Most of the light is, as before, directed
upwards to the ceiling for diffuse reflection and the rest reaches the working plane directly except for
some absorption by the bowl.

(v) General Diffusing System


In this system, luminaries are employed which have almost equal light distribution
downwards and upwards

101
4.8. Design of Lighting Schemes and Lay-outs

A well-designed lighting scheme is one which


(i) Provides adequate illumination
(ii) Avoids glare and hard shadows
(iii) Provides sufficiently uniform distribution of light all over the working plane.

Consider the following two factors which are of importance in determining the number, size and
proper arrangement of lamps in order to produce a given uniform illumination calculations.
a)Utilization Factor or Coefficient of Utilization (η )

It is the ratio of the lumens actually received by a particular surface to the total lumens emitted by
a luminous source.

η=

The value of this factor varies widely and depends on the following factors:

1. The type of lighting system, whether direct or indirect etc.


2. The type and mounting height of the fittings
3. The cplour and surface of walls and ceilings and
4. To some extent on the shape and dimensions of the room.
For example, for direct lighting, the value of η varies between 0.4 and 0.6 and mainly depends on
the shape of the room and the type and mounting height of fittings but very little on the colour of
walls and ceiling. For indirect lighting, its value lies between 0.1 and 0.35 and the effect of walls and
ceiling, from which light is reflected on the working plane, is much greater. Exact determination of
the value of utilization factor is complicated especially in small rooms where light undergoes multiple
reflections.
Since the light leaving the lamp in different directions is subjected to different degrees of
absorption, the initial polar curve of distribution has also to be taken into account. Even though
manufacturers of lighting fittings supply tables giving utilization factors for each type of fitting under
specified conditions yet, since such tables apply only to the fittings for which they have been
compiled, a good deal of judgment is necessary while using them.
b) Depreciation Factor (p)
This factor allows for the fact that effective candle power of all lamps or luminous sources
deteriorates owing to blackening and/or accumulation of dust or dirt on the globes and reflectors etc.
Similarly, walls and ceilings etc., also do not reflect as much light as when they are clean. The value
of this factor may be taken as 1/1.3 if the lamp fittings are likely to be cleaned regularly or 1/1.5 if
there is much dust etc.
c) Illumination under actual conditions

Φ =

Since illumination is specified in lm/m2, the area in square meter multiplied by the illumination
required in lm/m2 gives the total useful luminous flux that must reach the working plane. Taking into
consideration the utilization and depreciation or maintenance factors, the expression for the gross

102
lumens required is

Where E = desired illumination in lm/m2; A = area of working plane to be illuminated in m2 , p =


depreciation or maintenance factor ;η= utilization factor.

The size of the lamp depends on the number of fittings which, if uniform distribution is required,
should not be far apart. The actual spacing and arrangement is governed by space/height values and
by the layout of ceiling beams or columns. Greater the height, wider the spacing that may be used,
although the larger will be the unit required. Having settled the number of units required, the lumens
per unit may be found from (total lumens/number of units) from which the size of lamp can be
calculated
4.9. Lighting systems
1)Factory lighting
The factory lighting should be such so as to provide sufficient light without glare. If an adequate
lighting is provided, it will increase the rate of production, improve the quality, accident.
The lighting scheme should provide required illumination level with uniform distribution. The fittings
must be clean and should not provide glare.
The lamps should be mounted at sufficient height to provide even luminous intensity.
For some industries for machine operations, portable lights with reflectors may needed. Filament
lamps and fluorescent tubes are usually employed.

2) Floodlighting
It means ‘flooding’ of large surfaces with the help of light from powerful projectors. Flooding is
employed for the following purposes.

 For aesthetic purposes as for enhancing the beauties of building by night i.e. flood lighting of
ancient monuments, religious buildings on important festive occasions etc.

 For advertising purposes i.e. flood lighting, huge hoardings and commercial buildings.

 For industrial and commercial purposes as in the case of railway yards, sports stadiums and
quarries etc.

For flood lighting it is necessary to concentrate the light from the lamp into a relatively narrow beam.
Lamp is accurately controlled and covered into a narrow beam by means of projector
However, in the case of flood-lighting, one more factor has to be taken into account. That factor is
known as waste-light factor (W). It is so because when several projectors are used, there is bound to
be a certain amount of overlap and also because some light would fall beyond the edges of the area to
be illuminated. These two factors are taken into account by multiplying the theoretical value of the
flux required by a waste-light factor which has a value of nearly 1.2 for regular surfaces and about 1.5
for irregular objects like statues etc. Hence, the formula for calculation of total flux required for
floodlighting purposes

EAW
Φ = ηp

Where E = desired illumination in lm/m2; A = area of working plane to be illuminated in m2


p = depreciation or maintenance factor; η= utilization factor.

103
The size of the lamp depends on the number of fittings which, if uniform distribution is required,
should not be far apart. The actual spacing and arrangement is governed by space/height values and
by the layout of ceiling beams or columns. Greater the height, wider the spacing that may be used,
although the larger will be the unit required. Having settled the number of units required, the lumens
per unit may be found from (total lumens/number of units) from which the size of lamp can be
calculated
3) Street lighting
The main purposes of street lighting are
i) To make the traffic and instructions on the road clearly visible.
ii) To make the street more attractive.
The principle behind street lighting is different from that of indoor lightning. There are no walls and
ceiling which reflect or diffuse light. Hence only direct lighting scheme can be employed. Therefore it
is not possible to avoid hard shadows and high contrast.
For economic reasons, very low value of illumination is used compared to indoor lighting since areas
to be illuminated are usually large. For proper illumination of street the diffusion and specular
principles are usually employed.
i) Diffusion principle
The lamps are fitted with suitable reflectors to spread the light as uniformly as possible over the road
service. The reflectors are so shaped that the lamp filament is not visible except from underneath it.
This avoid glare.
ii) Specular reflection
The reflector should be designed such that, the light falls on an object at a very large angle of incident
and reflected correspondingly large angle.
But this produce glare and is only suitable for straight sections of the road.
All light fittings should be mounted solid so that they should not swing due to breeze. Lamp posts
should always be fixed at the junction of two roads. Lamps near to large trees and shadows to be
avoided.

Example 4.1.A room 8 m X 12 m is lighted by 15 lamps to a fairly uniform illumination of 100


lm/m2. Calculate the utilization coefficient of the room given that the output of each lamp is 1600
lumens.

Solution. Lumens emitted by the lamps = 15 X1600 = 24,000 lm

Lumens received by the working plane of the room =


=8 X 12 X 100 = 9600lm

Utilization coefficient = 9600/24,000 = 0.4 or 40%.

Example 4.2 The illumination in a drawing office 30 mX10 m is to have a value of 250 luxand is to
be provided by a number of 300-W filament lamps. If the coefficient of utilization is 0.4 and the
depreciation factor 0.9, determine the number of lamps required. The luminous efficiency of each
lamp is 14 lm/W.

Solution. Φ = E A/ηp; E = 250 lm/m2, A = 30 x 10 = 300 m2; η = 0.4, p = 0.9

104
Φ =

∴Φ = 250 x 300/0.4 x 0.9 = 208,333 lm

Flux emitted/lamp = 300 x 14 = 4200 lm;

No. of lamps reqd.= 208,333/4200 = 50.

Example 4.3 it is required to provide an illumination of 100 lux in a factory hall 30m x 15m. Assume
the depreciation factor is 0.8, coefficient of utilization is 0.4 and efficiency of lamp is 14 lumen/watt.
Suggest the number of lamps and their ratings are 100w,250w,400w and 500w.

Solution:
Illumination required E = 100 lux
Area to be illuminated A = 30 x 15= 450 m2
D.F =0.8 , U.F =0.4 , Lumens/watt =14

Total lumen = Φ =

=Φ = =140625
Total wattage required = = = 10044.6W=10,000W

Number of lamps 100W = = 100

Number of lamps 250W = =40


Number of lamps 100W = = 25

Number of lamps 100W = = 20


Example 4.4.
A factory of size 20 m*20 m is to be illuminated, so as to get the illumination of 20 lux at
working plane .Find the number of lamps to be provided.(use twin tube lights of each 40 w)

Solution:
1. Assumptions:
1. Area of room 20 mX20 m=400 sq m
2. Illumination required =20 lux
3. Deprecation factor= 0.7
4. Coefficient of utilization= 0.4
5. Efficiency of lamps=10.5 lumen/watt
6. Three phase 4 wire system is needed.
7. Height of ceiling=4m
8. Fluorecent twin tube light sets to be hang below ceiling =1m

105
Total illumination required =

= 28571 lumens.

Wattage required = = =2721watts


If we select 80 w lamps =2721/80 =34 lamps
For room size 20 m*20 m we can select the lamps with space between lamps=2X2m.
The load can be distributed as:
In each bay =5 lamps, Totally 5 bays,
1.Therefore total lamps=5X5 =25 twin tube lights of each 80w=25X80 =2000w
2.In all four side walls four numbers of lamps of 100w =4X100w =400w
3.In front side entrance three numbers of 100w lamps =3X100 =300w
4.In back side wall one lamp of 100w =1X100 =100w

4.10.Sources of light
Various sources of lights are
i) Natural sources ex: sun, stars…
ii) Artificial Sources of Light ex: candles, kerosense lamps, petromax…

The different methods of producing light by electricity may, in a broad sense, be divided into three
groups.

106
1. By temperature incandescence. In this method, an electric current is passed through a filament of
thin wire placed in vacuum or an inert gas. The current generates enough heat to raise the temperature
of the filament to luminosity.
Incandescent tungsten filament lamps are examples of this type and since their output depends on the
temperature of their filaments, they are known as temperature radiators.

2. By establishing an arc between two carbon electrodes. The source of light, in their case, is the
incandescent electrode.

3. Discharge Lamps. In these lamps, gas or vapor is made luminous by an electric discharge through
them. The cplour and intensity of light i.e. candle-power emitted depends on the nature of the gas or
vapor only. It should be particularly noted that these discharge lamps are luminescent-light lamps and
do not depend on temperature for higher efficiencies. In this respect, they differ radically from
incandescent lamps whose efficiency is dependent on temperature. Mercury vapor lamp, sodium-
vapor lamp, neon-gas lamp and fluorescent lamps are examples of light sources based on discharge
through gases and vapors.

4.11.Incandescent Lamp

An incandescent lamp essentially consists of a fine wire of a high-resistance metal placed in an


evacuated glass bulb and heated to luminosity by the passage of current through it. Such lamps were.
The superiority of tungsten lies mainly in its ability to withstand a high operating temperature
without undue vaporization of the filament. The necessity of high working temperature is due to the
fact that the amount of visible radiation increases with temperature and so does the radiant efficiency
of the luminous source.
In these lamps, the current is passed through a fine wire or filament of suitable material (tungsten), it
is heated and temperature of the wire raises and heat as well as light energy will be radiated at low
temperature.
At high temperature, the heat as well as light energy will be radiated, higher temperature of the wire,
higher the amount of light energy radiated.
It is necessary to use a substance which can be made into a fine filament and raised quickly to a high
temperature without being destroyed.
In fact, the ideal material for the filament of incandescent lamps is one which has the following

107
properties:

1. A high melting and hence operating temperature

2. A low vapor pressure

3. A high specific resistance and a low temperature coefficient

4. Ductility and mechanically strong


5. Sufficient mechanical strength to withstand vibrations.

Since tungsten possesses practically all the above mentioned qualities, it is used in almost all
modern incandescent lamps.
The object of vacuum was twofold :
(a) To prevent oxidation and
(b) To minimize loss of heat by convection and the consequent lowering of filament temperature.
However, vacuum favored the evaporation of the filament with the resulting blackening of the lamp
so that the operating

4.12. Arc lamp

An arc lamp or arc light is a lamp that produces light by an electric arc (also called a voltaic
arc). It continued in use in more specialized applications where a high intensity point light
source was needed, such as searchlights and movie projectors until after World War II. The
carbon arc lamp is now obsolete for all of these purposes and is only still made for very
specialized purposes where a high intensity UV source is needed.

The term is now used for gas discharge lamps, which produce light by an arc between metal
electrodes through an inert gas in a glass bulb. The common fluorescent lamp is a low-
pressure mercury arc lamp. The xenon arc lamp, which produces a high intensity white light,
is now used in many of the applications which formerly used the carbon arc, such as movie
projectors and searchlights.

An arc is the discharge that occurs when a gas is ionized. A high voltage is pulsed across the
lamp to "ignite" or "strike" the arc, after which the discharge can be maintained at a lower
voltage. The "strike" requires an electrical circuit with an igniter and a ballast. The ballast is
wired in series with the lamp and performs two functions.

First, when the power is first switched on, the igniter/starter (which is wired in parallel across
the lamp) sets up a small current through the ballast and starter. This creates a small magnetic
field within the ballast windings. A moment later the starter interrupts the current flow from
the ballast, which has a high inductance and therefore tries to maintain the current flow (the
ballast opposes any change in current through it); it cannot, as there is no longer a 'circuit'. As
a result, a high voltage appears across the ballast momentarily - to which the lamp is
connected, therefore the lamp receives this high voltage across it which 'strikes' the arc within
the tube/lamp. The circuit will repeat this action until the lamp is ionized enough to sustain
the arc.
108
When the lamp sustains the arc, the ballast performs its second function, to limit the current
to that needed to operate the lamp. The lamp, ballast and igniter are rated matched to each
other; these parts must be replaced with the same rating as the failed component or the lamp
will not work.

A krypton arc lamp during operation:

The temperature of the arc in an arc lamp can reach several thousand degrees Celsius. The
outer glass envelope can reach 500 degrees Celsius, therefore before servicing one must
ensure the bulb has cooled sufficiently to handle. Often, if these types of lamps are turned off
or lose their power supply, one cannot restrike the lamp again for several minutes (called cold
restrike lamps). However, some lamps (mainly fluorescent tubes/energy saving lamps) can be
restruck as soon as they are turned off (called hot restrike lamps).

. In a carbon arc lamp, the electrodes are carbon rods in free air. To ignite the lamp, the rods
are touched together, thus allowing a relatively low voltage to strike the arc.The rods are then
slowly drawn apart, and electric current heats and maintains an arc across the gap. The tips of
the carbon rods are heated and the carbon vaporizes. The carbon vapor in the arc is highly
luminous, which is what produces the bright light. The rods are slowly burnt away in use, and
the distance between them needs to be regularly adjusted in order to maintain the arc.

The Yablochkov candle is a simple arc lamp without a regulator, but it has the drawbacks that
the arc cannot be restarted (single use) and a limited lifetime of only a few hour

Arc lamps were used in some early motion-picture studios to illuminate interior shots.
These were used aboard warships of all navies during the 20th century for signaling and illuminating
enemies. In the 1920s, carbon arc lamps were sold as family health products, a substitute for natural
sunlight, cinema projection, follow spots, and searchlights.

109
4.13. Halogen lamp

In incandescent lamps, the life and efficiency is reduced due to slow evaporation of filament and also
due to black deposits formed on inner side of the bulb. The addition of a small amount of halogen
vapor to the iodine gas restores part of the evaporated tungsten back to the filament by means of
chemical reaction. This eliminated blackening which is normally caused by a deposit of evaporated
tungsten on the walls of the envelope and a high luminous efficiency is maintained throughout the life
of the lamp. The life of the halogen lamp is nearly double the tungsten filament lamp as the small
envelope is used with resultant high gas filling pressure.
Advantages
i) Long life
ii) Better colour emitting
iii) No blackening of lamp, so no depreciation of lumen output through out the life of the lamp.
iv) Better luminous efficiency
v) Reduced dimensions of lamp is offered.
vi) Manufacturedupto 5kW.

Applications
Suitable for outdoor illumination of buildings, play ground, car parks, air port run ways, large garden

110
4.14.SodiumVapour Lamp

The glass of the inner tube is a special chemical resistant glass and is capable to withstand chemical
action of hot sodium. One type of low-pressure sodium-vapour lamp along with its circuit connection
is shown in Fig. It consists of an inner U-tube, containing small amount of sodium. Neon gas and
electrodes. The tube is made of a special sodium-vapour-resisting glass. It houses the two electrodes
and contains sodium together with the small amount of neon-gas at a pressure of about 10 mm of
mercury and one per cent of argon whose main function is to reduce the initial ionizing potential. The
discharge is first started in the neon gas (which gives out redish colour). After a few minutes, the heat
of discharge through the neon gas becomes sufficient to vaporise sodium and then discharge passes
through the sodium vapour. In this way, the lamp starts its normal operation emitting its characteristic
yellow light
They have a starting time of 5 to 6 minutes. They go off and cannot be restarted after the recovery of
the voltage till its value falls to the normal value. The colour of their light is yellowish and produces
cplour distortion.
The tungsten-coated electrodes are connected across auto-transformer T having a relatively high
leakage reactance. The open-circuit voltage of this transformer is about 450 V which is sufficient to
initiate a discharge through the neon gas. The leakage reactance is used not only for starting the
current but also for limiting its value to safe limit. The electric discharge or arc strikes immediately
after the supply is switched on whether the lamp is hot or cold. The normal burning position of the
lamp is horizontal although two smaller sizes of lamp may be burnt vertically. The lamp is surrounded
by an outer glass envelope B which serves to reduce the loss of heat from the inner discharge tube A .
In this way, B helps to maintain the necessary high temperature needed for the operation of a sodium
vapour lamp irrespective of draughts. The capacitor C is meant for improving the power factor of the
circuit.
The light emitted by such lamps consists entirely of yellow colour. Like sodium-vapour lamp, this
lamp is also classified as electric discharge lamp in which light is produced by gaseous conduction.
Such a lamp usually consists of two bulbs — an arc-tube containing the electric discharge and an
outer bulb which protects the arc-tube from changes in temperature.
.
As compared to an incandescent lamp, a mercury-vapour lamp is (a) smaller in size (b) has 5 to
10 times longer operating life and (c) has 3 times higher efficiency i.e. 3 times more light output for
given electrical wattage input.

111
4.15. High-pressure Mercury Vapour Lamp

They take 5 to 6 minutes for starting. They go off and cannot be restarted after the recovery of the
voltage till the pressure falls to normal. They suffer from high colour distortion. They are suitable for
open space like yards, parks and highway lighting etc. Change in voltage effects their starting time
and colour of radiations emitted by them. Switching does not affect their life period. They have very
limited utility that too on mains voltage. They are suitable for vertical position of working. They have
an average working life of 3000 hours and an efficiency of 40 lm/W.
Like sodium-vapour lamp, this lamp is also classified as electric discharge lamp in which light is
produced by gaseous conduction. Such a lamp usually consists of two bulbs — an arc-tube containing
the electric discharge and an outer bulb which protects the arc-tube from changes in temperature. The
inner tube or arc tube A is made of quartz (or hard glass) the outer bulb B of hard glass. As shown in
Fig., the arc tube contains a small amount of mercury and argon gas and houses three electrodes D, E
and S. The main electrodes are D and E whereas S is the auxiliary starting electrode. S is connected
through a high resistance R (about 50 kΩ ) to the main electrode situated at the outer end of the tube.
The main electrodes consist of tungsten coils with electron-emitting coating or elements of thorium
metal.
When the supply is switched on, initial discharge for the few seconds is established in the argon gas
between D and S and then in the argon between D and E. The heat produced due to this discharge
through the gas is sufficient to vaporize mercury. Consequently, pressure inside A increases to about
one or two atmospheres and the p.d. across D and E grows from about 20 to 150 V, the operation
taking about 5-7 minutes. During this time, discharge is established through the mercury vapours
which emit greenish-blue light.
The choke serves to limit the current drawn by the discharge tube A to a safe limit and capacitor C
helps to improve the power factor of the circuit.
True colour rendition is not possible with mercury vapour lamps since there is complete absence
of red-light from their radiations. Consequently, red objects appear black, all blues appear mercury-
spectrum blue and all greens the mercury-spectrum green with the result that colour values are
distorted.
There has been tremendous improvement in the construction and operation of mercury-vapour
lamps, which has increased their usefulness and boosted their application for all types of industrial
lighting, floodlighting and street lighting etc. As compared to an incandescent lamp, a mercury-
vapour lamp is (a) smaller in size (b) has 5 to 10 times longer operating life and (c) has 3 times higher
efficiency i.e. 3 times more light output for given electrical wattage input.

112
Typical mercury-vapour lamp applications are :
Typical mercury-vapour lamp applications are :

1. High-bay industrial lighting — where high level illumination is required and colour rendition
is not important.
2. Flood-lighting and street-lighting
3. Photochemical applications — where ultra-violet output is useful as in chlorination, water
sterilization and photocopying etc.
4. For a wide range of inspection techniques by ultra-violet activation of fluorescent and phos-
phorescent dyes and pigments.
5. Sun-tan lamps — for utilizing the spectrum lines in the region of ultra-violet energy for
producing sun-tan.

4.16.Fluorescent Lamps.

The Fluorescent tube consists of a glass tube 25mm in diameter and 0.6mt, 1.2mt and 1.5 mt in
length. The tube contains argon gas at low pressure of 2.5 mt and one or two drops of mercury
and inside surface of the tube is coated with a thin layer of Fluorescent material in the form of a
powder. The coating material used depends upon the colour effect desired and may consists of
zinc silicate, cadmium silicate or calcium tungsten. These organic chemicals are known as
phosphorous which transformers short waves invisible radiation into visible light.
At start, current is passed through filaments which get heated up and emit electrons. This is
achieved by use of choke with starter.
The choke is connected in series with the tube which acts as ballasts in running conditions and
provides a high voltage impulse or surge for starting. At the time when switch is operated the
starter is provided and the electrodes get heated and
Start emitting sufficient electrons. The switches or starters are of two types:
a) Thermal type starter b) Glow type starter
Circuit diagram of fluorescent lamp with glow type starter is shown.
The bimetallic strips of the starter are normally open. When the supply is switched ON, full
voltage is available across the bimetallic strips of the starter. This discharge heats the bimetallic
strips of the starter causing them to bend and make contact. Now the tube filaments get heated and
emit electrons inside the tube due to flow of current.
Now the voltage across the strips of the starter is reduced to zero. Hence the bimetallic strips cool
down and the contacts open. Due to the change of current, high voltage is induced in the choke e=
L di/dt. The high voltage produces an arc between the filaments of the tube. Hence the mercury in
the tube discharges and the tube emit light. After the establishment of light in the tube , the
voltage maintain light is reduced to 110V.As the tube current flows through the choke , sufficient

113
voltage drop occurs in the choke. There by allowing only the required voltage to be applied across
the tube. Also the choke limits the current in the lamp circuit. Due to the choke, the power factor
of the circuit is low. Hence to improve the power factor a capacitor is connected across the
supply.

Advantages
i) Efficiency and life under normal conditions are three times of those for filament lamp
ii) The quality of light obtained is much superior.
Since stroboscopic effect is present, they are suitable for semi-direct lighting, domestic, industrial,
commercial, roads and halls etc.

4.17.Induction lamp

The internal electrodes lamp or induction light is a gas discharge lamp in which the power
required to generate light is transferred from outside the lamp envelope to the gas inside via an
electric or magnetic field, in contrast with a typical gas discharge lamp that uses internal
electrodes connected to the power supply by conductors that passes through the lamp envelop.
There are two advantages to elimination of the internal electrodes.
1. Extended lamp life
2. The ability to use light generating substances of higher efficiency that would react with
internal metal electrodes in normal lamps

Two types of lamps


1. Plasma lamps
2. Fluorescent induction lamp

1. Plasma lamps which uses electrostatic induction to energies a bulb filled with sulfur vapor or
metal halides.

2. Fluorescent induction lamps, based upon a conventional fluorescent lamp bulb in which
current is induced by an external coil of wire via electrodynamics induction.

114
4.18. Energy saving lamps (CFL & LED)

a).Compact fluorescent lamp

A compact fluorescent lamp (CFL), also called compact fluorescent light, energy-saving
light, and compact fluorescent tube, is a fluorescent lamp designed to replace an incandescent light
bulb. Some types fit into light fixtures designed for incandescent bulbs. The lamps use a tube which is
curved or folded to fit into the space of an incandescent bulb, and a compact electronic ballast in the
base of the lamp.

The principle of operation remains the same as in other fluorescent lighting: electrons that
are bound to mercury atoms are excited to states where they will radiate ultraviolet light as they return
to a lower energy level; this emitted ultraviolet light is converted into visible light as it strikes the
fluorescent coating (as well as into heat when absorbed by other materials such as glass).

Conventional light fixture using an adapter containing a built-in magnetic CFLs have two
main components: a magnetic or electronic ballast and a gas-filled tube where ballasts contain a small
circuit board with a bridge rectifier, a filter capacitor and usually two switching transistors, which are
often insulated-gate bipolar transistors. The incoming AC current is first rectified to DC, and then
converted to high frequency AC by the transistors, connected as a resonant series DC to AC inverter.
The resulting high frequency is applied to the lamp tube. Since the resonant converter tends to
stabilize lamp current (and light produced) over a range of input voltages. CFLs emit light from a mix
of phosphors, each emitting one band of colour with some bands still in the ultraviolet range as can be
seen on the light spectrum. This is the reason why additional UV filtering, for example double-
envelope, is required to reduce damage to the retina.

CFL light output is roughly proportional to phosphor surface area. Standard shapes of CFL tube
are a helix with one or more turns, multiple parallel tubes, circular arc, or a butterfly.

115
CFLs use three or four phosphors to achieve a "white" light with a colour rendering index (CRI) of
about 80, where the maximum 100 represents the appearance of colours under daylight or other
sources of black-body radiation such as an incandescent light bulb

b) There are two types of CFLs:

1. Integrated 2. Non-integrated lamps

Integrated lamps combine the tube and ballast in a single unit. These lamps allow consumers to
replace incandescent lamps easily with CFLs. Integrated CFLs work well in many standard
incandescent light fixtures, reducing the cost of converting to fluorescent. 3-way lamps and dimmable
models with standard bases are available.

Non-integrated CFLs have the ballast permanently installed in the luminaries. Non-integrated CFL
housings can be both more expensive and sophisticated. They have two types of tubes: a bi-pin tube
designed for conventional ballast, and a quad-pin tube designed for electronic ballast or conventional
ballast with an external starter.

c) Comparison of CFL with incandescent lamp:

 If a building's indoor incandescent lamps are replaced by CFLs, the heat produced due to
lighting is significantly reduced. In warm climates or in office or industrial buildings where
air conditioning is often required, CFLs reduce the load on the cooling system when
compared to the use of incandescent lamps, resulting in savings in electricity in addition to
the energy efficiency savings of the lamps themselves
 CFLs typically have a rated service life of 6,000–15,000 hours, whereas standard
incandescent lamps have a service life of 750 or 1,000 hours
 Compared to general-service incandescent lamps giving the same amount of visible light,
CFLs use one-fifth to one-third the electric power, and last eight to fifteen times longer.
 A CFL has a higher purchase price than an incandescent lamp, but can save over five times its
purchase price in electricity costs over the lamp's lifetime
 CFLs radiate a spectral power distribution that is different from that of incandescent lamps.
Improved phosphor formulations have improved the perceived colour of the light emitted by
CFLs, such that some sources rate the best "soft white" CFLs as subjectively similar in colour
to standard incandescent lamps

d) Limitations of CFL

 CFLs, like all fluorescent lamps, contain mercury as vapor inside the glass tubing.
 Like all fluorescent lamps, CFLs contain toxic mercury] which complicates their disposal. In
many countries, governments have banned the disposal of CFLs together with regular
garbage.
 Most CFLs contain 3–5 mg per bulb, with the bulbs labeled "eco-friendly" containing
as little as 1 mg.
 Because mercury is poisonous, even these small amounts are a concern for landfills
and waste incinerators where the mercury from lamps may be released and contribute
to air and water pollution.
 Health and environmental concerns about mercury have prompted many jurisdictions
to require spent lamps to be properly disposed of or recycled, rather than being

116
included in the general waste stream sent to landfills. Safe disposal requires storing
the bulbs unbroken until they can be processed.

4.19. LED lamp


An LED lamp is a light-emitting diode (LED) product that is assembled into a lamp (or light
bulb) for use in lighting fixtures. LED lamps have a lifespan and electrical efficiency which are
several times greater than incandescent lamps, and are significantly more efficient than most
fluorescent lamps

General-purpose lighting needs white light. LEDs emit light in a very narrow band of
wavelengths, emitting light of a colour characteristic of the energy band gap of the semiconductor
material used to make the LED. To emit white light from LEDs requires either mixing light from
LEDs of various colours, or using a phosphor to convert some of the light to other colours.

The two simplest methods of producing white light LEDs are RGB or phosphor. RGB or tri
chromatic white LEDs uses multiple LED chips emitting red, green, and blue wavelengths. These
outputs combine to produce white light. The colour rendering index (CRI) is poor, typically 25 - 65,
and due to the narrow range of wavelengths emitted.

The second basic method uses LEDs in conjunction with a phosphor to produce complementary
colours from a single LED. The most common method is to combine a blue LED with a yellow
phosphor, producing a narrow range of blue wavelengths and a broad band of "yellow" wavelengths
actually covering the spectrum from green to red. The CRI value can range from less than 70 to over
90, although a wide range of commercial LEDs of this type have a colour rendering index around 82.

LED lamps are used for both general and special-purpose lighting. Where coloured light is
needed, LEDs that inherently emit light of a single colour require no energy-absorbing filters.

White-light LED lamps have longer life expectancy and higher efficiency (more light for the same
electricity) than most other lighting when used at the proper temperature. LED sources are compact,

117
which gives flexibility in designing lighting fixtures and good control over the distribution of light
with small reflectors or lenses. Because of the small size of LEDs, control of the spatial distribution of
illumination is extremely flexible, and the light output and spatial distribution of an LED array can be
controlled with no efficiency loss.

LEDs using the colour-mixing principle can emit a wide range of colours by changing the proportions
of light generated in each primary colour. This allows full colour mixing in lamps with LEDs of
different colours.

a)Advantages of LED lamps

 In keeping with the long life claimed for LED lamps, long warranties are offered
 Reduces energy costs — uses at least 75% less energy than incandescent lighting, saving on
operating expenses.
 Reduces maintenance costs — lasts 35 to 50 times longer than incandescent lighting and
about 2 to 5 times longer than fluorescent lighting. No lamp-replacements, no ladders, no
ongoing disposal program.
 Reduces cooling costs — LEDs produce very little heat.
 Is guaranteed — comes with a minimum three-year warranty — far beyond the industry
standard.
 Offers convenient features — available with dimming on some indoor models and automatic
daylight shut-off and motion sensors on some outdoor models.
 Is durable — won’t break like a bulb.

Limitations
 Many will not work with existing dimmer switches designed for [higher power] incandescent
lamps.
 Colour rendering is not identical to incandescent lamps which emit close to perfect Black-
body radiation as that from the sun and for what eyes have evolved.
 LED efficiency and life span drop at higher temperatures,.
 LED lamps are sensitive to excessive heat, like most solid state electronic components.
 The long life of LEDs, expected to be about 50 times that of the most common incandescent
lamps and significantly longer than fluorescent types.

118
4.20.Comparison of Incandescent, CFL,LED lamps

Sl.no Property Incandescent CFL LED

1
Watts 60 14 6.5

2 lumens (mean) 860 775 800

3 lumens/watt 14.3 55.4 123.1

Cplour Temperature
4 2700 2700 2700
kelvin

5 CRI 100 82 80

6 Lifespan (hours) 1,000 10,000 15,000

Review questions
Part A & B
1. What is the normal Space –height ratio of industrial Lighting?
2. What is Flood Lighting?
3. Mention the power ratings of CFL?
4. What is meant by Illumination?
5. What are the factors to be consider while designing good lighting system
6. State the requirements of good lighting system?
7. State the disadvantages of Incandescent lamp?
8. Define Utilization factor.
9. What is the energy saving procedures for fluorescent lamp?
10. Explain the two types of induction lamp.
11. Define Luminous Intensity
12. Explain the two types of CFL.
13. What are the advantages of CFL over Fluorescent tube?
14. Justify that the gaseous lamp
15. How stroboscopic effect can be avoided?
16. How is discharge lamps are superiors than Incandescent lamp?
17. Explain Lamberts Cosine Law.
18. What the factors to be considered while designing Indoor Lighting Scheme?
19. What are the Advantages of LED lamps
20. What are the Limitations of CFL
21. What are the applications of mercury-vapour lamp
22. What are the advantages and applications of halogen lamp?

119
Part C
14. State and explain the 2 laws of Illumination.
15. Explain with a sketch the working of High pressure mercury Vapour lamp.
16. Explain with a sketch the working of sodium vapour lamp.
17. List the five types of Lighting Schemes with a brief note on each type.
18. Give a Detailed account of Fluorescent lamp of various types? What are their advantages and
Disadvantages as compared to other light sources?
19. Explain with a sketch the working of incandescent lamp.
20. Explain with a sketch the working of halogen lamp.
21. Explain with a sketch the working of induction lamp
22. Explain with a sketch the working of carbon arc lamp
23. Explain with a sketch the working of CFL & LED lamp
24. Explain the various factors to be taken into account for designing scheme for (i)street lighting
(ii)flood lighting

120
UNIT V

ELECTRIC HEATING and WELDING


5.1.1. INTRODUCTION – HEATING

Electric heating is preferred than other heating methods because of its simplicity. Electric heating is
based on the principle that when electric current passed through a medium, heat will be produced.
Electric heating characteristics of current is used in industrial & domestic heating appliances

ADVANTAGES OF ELECTRIC HEATING

 Economical
 High Ƞ (75 to 100%)
 Cleanliness
 Absence of flue gases
 Ease of control
 Automatic protection
 Localized application
 Uniform heating
 Low attention & low maintenance cost
 Better working conditions
5.1.2. CLASSIFICATION OF HEATING METHODS BASED ON TEMPERATURE RANGE
 Low temperature heating ( upto 4000 C )

 Medium temperature heating (4000- 11500C)

 High temperature heating ( above 11500 C )

5.1.3. MODES OF HEAT TRANSFER

1. Conduction

Heat transfer depends on temperature difference between parts of body

Heated molecules transform heat to adjacent molecules

Applicable for Solids

2. Convection

By actual motion of particles

Applicable for Liquids

Amount of heat dissipation = 3.876X10-4(T1- T2)1.25 Watts / cm2

T1 = Temperature of heating surface

T2 = Temperature of air

121
3. Radiation

By heat Waves

Do not heat the medium between bodies

Heat the body which intercepts waves

Heat transmitted = 5.72X104ke { (T1/1000)4 – (T2/1000)4} Watts / cm2

k = radiating efficiency

e = emissivity constant

T1 = Temperature of heating surface

T2 = Temperature of substance to be heated

5.1.4. TYPES OF ELECTRIC HEATING:

I. Power frequency heating


a) Direct resistance heating
b) Indirect resistance heating
c) Radiant / Infra red heating
d) Salt bath heating
II. High frequency heating
a) Direct induction heating
b) Indirect induction heating
c) Dielectric heating
d) Electric arc heating

5.1.5. DIRECT RESISTANCE HEATING

Working principle:

In this method the material (or charge) to be heated is treated as a resistance and current is passed
through it. The charge may be in the form of powder, small solid pieces or liquid. The two electrodes
are inserted in the charge and connected to either a.c. or d.c. supply . Obviously, two electrodes will
be required in the case of d.c. or single-phase a.c. supply but there would be three electrodes in the
case of 3-phase supply. When metal pieces are to be heated, a powder of high resistivity material is
sprinkled over the surface of the charge to avoid direct short circuit.. Heat is produced when current
passes through it. This method of heating has high efficiency because the heat is produced in the
charge itself.

 Material to be heated is called as Charge

 Non- metal Charges are in the forms of Powder, Pieces or liquid

 They form a resistance for the current flow

 For heating Metal Charges, High resistance powder is sprinkled, to avoid short circuit

 DC & 1 Ø AC supplies – 2 Electrodes

122
 3 Ø AC supply – 3 Electrodes

Fig. 5.1 Direct Resistance Heating

ADVANTAGES

 High Ƞ

 Gives uniform heat

 Gives high temperature

DISADVANTAGES

 Current is not easily variable

 Automatic temperature control is not possible

5.1.6. INDIRECT RESISTANCE HEATING

Working principle: In this method of heating, electric current is passed through a resistance element
which is placed in an electric oven. Heat produced is proportional to I 2 R losses in the heating
element. The heat so produced is delivered to the charge either by radiation or convection or by a
combination of the two. Sometimes, resistance is placed in a cylinder which is surrounded by the
charge placed in the jacket as shown. This arrangement provides uniform temperature. Moreover,
automatic temperature control can also be provided.

ADVANTAGES

1. Gives uniform heat

2. Automatic temperature control is possible

DISADVANTAGES

123
 Lower efficiency.

5.1.7. INFRA RED / RADIANT HEATING

Working principle:

This type if heating is used for low and medium temperatures. In this method a special
tungsten filament lamp is operated at the temperature of 2300°C. The lamp at this temperature emits a
large amount of infra red radiation. Operating the lamp at this temperature also increases the life of
the filament. In comparison to other resistance heater, this lamp emits a large amount of heat, which is
being reflected to the charge. In this method, heat emission about 7500 watts/m² can be obtained. The
temperature of charge obtained will be 200 to 300°C.

This type of heating is employed in drying paint and foundry moulds and plastic heating at
low temperatures.

Fig. 5.3Infra Red Heating

ADVANTAGES

1. High heat transfer rate

2. Reduce the heating time

3. Heat absorption is more

APPLICATIONS

1. Paint drying

2. Plastic heating at low temperatures

3. Foundry molding

5.1.8. ARC HEATING

When high voltage is applied across two electrodes separated by air gap, air is ionized due to
electrostatic stress. The Ionized air is a conducting material, therefore Current starts flowing through
air gap, by continuous sparks i.e. arc with Graphite / Carbon electrodes, temperature obtained will be
30000 C to 35000 C

124
a)Direct Arc Heating

Direct& Indirect Arc Heating methods are discused in detail under arc furnaces topic later as
the principle is the same for both.

Fig. 5.4Direct Arc Heating

Fig. 5.5 Indirect Arc Heating

b)Indirect Arc Heating

5.1.9.HIGH FREQUENCY ELECTRIC HEATING- INDUCTION HEATING

Working principle:
Introduction heating is based on the transformer principle. There is a primary
winding through which an a.c current is passed. The coil is magnetically coupled with the metal to be
heated, which acts as the secondary. When an a.c current is passed through the primary winding, an

125
electric current will be induced in the metal. This induced current produce heat in the metal.
Alternating current induced in charge depends upon magnitude of primary current

Fig.5.6 Induction Heating

USES OF INDUCTION HEATING

 Surface hardening
 Deep hardening
 Tempering
 Soldering
 Melting
 Smelting (Extraction of metals from their ores)

Example: INDUCTION STOVE

Induction stoves cook by magnetic induction, instead of thermal conduction, by flame or electrical
heater
Usually have glass tops and Heats the pot/vessel directly. Rapid increase in temperature is achieved
by a copper coil in induction stove is given with high frequency ac supply ( Eg.24 KHz).The
oscillating magnetic field induces a magnetic flux, which magnetizes the pot placed over the stove
and the pot acts as the core of a transformer so, large eddy currents are produced in the pot, based on
its resistance for heating.
Cooking vessel/pot must be made of, or contain, a ferromagnetic metal ( Cast iron, Stainless steel,
etc.)

Advantages

1. Highly efficient (Fast heating)


2. Less wastage of heat
3. Can be quickly turned off
4. Safe (No hazardous temperature)
5. Easy to clean
6. Consistent

Fig.5.6 a. Induction stove - Principle

126
Fig.5.6 b. Induction stove ( Only for understanding purpose)

Disadvantages

1. Cooking vessel should be ferromagnetic


2. Noise production due to running fan inside stove
3. Some cooking techniques are not applicable
4. Persons with implanted cardiac pacemakers should avoid magnetic fields from induction
stove
5. Radio receivers near stove may pick up electromagnetic interference
6. Costlier
7. Needs electricity

5.1.10.a) EDDY CURRENT HEATING

Working principle:

 High frequency eddy current heating is nothing but a form of induction heating.
Usually if is used for hardening, annealing and tempering of machine parts. The machine part to be
heated is surrounded by a coil through which an alternating current at high frequency is passed.
Electromagnetic field in coil produces heating effect, due to eddy currents set up.

Area of the machine parts or metal. The heating effect is due to eddy currents set up in
the machine parts. Due to skin effect the induced heating current concentrate near the surface of the
conductor through which flux is set up. At high frequencies the eddy currents developed are
concentrated at the surface. Therefore high frequency is used for heating light machine parts and low
frequency is used for heavy machine parts.

Fig.5.7 a. Eddy Current Heating

127
Fig.5.7 b. Eddy Current Heating(Only for understanding purpose)

Applications

1. Hardening, Annealing & Tempering of machine parts

2. Zonal Heating

3. Hardening of drilled holes

4. Hardening of shafts, tools, endless saw blades & Gears

5. Soldering

6. Vacuum tube heating

b) DIELECTRIC HEATING

Working principle:

Dielectric heating is also sometimes called as high frequency capacitance heating. If non metallic
materials ie, insulators such as wood, plastics, china clay, glass ceramics etc are subjected to high voltage
A.C current , their temperature will increases after some time. The increase in temperature is due to the
conversion of dielectric loss into heat. The dielectric loss is dependent upon the frequency and high
voltage. Therefore for obtaining high heating effect high voltage at high frequency is usually employed.
The metal to be heated is placed between two sheet type electrodes which form a capacitor.
When A.C supply is connected across the two electrodes, the current drawn by it is leading the
voltage exactly 90°. The angle between voltage and current is slightly less than 90°, with the result that

128
there is a in phase component of the current. This current produces power loss in the dielectric of the
capacitor.
At normal supply frequency the power loss may be small. But at high frequencies, the loss becomes
large which is sufficient to heat the dielectric. Rate of heat production can also be increased by applying
high potential but it is also limited because of the following considerations:

(a) Possibility of formation of standing waves between the surface of two electrodes having
wavelength nearly equal to or more than one quarter of the wavelength of the particular frequency
used.
(b) Necessity of employing special matching circuit at higher frequencies due to the fact that
maximum power transfer takes place when the oscillator impedance equals the load impedance.
(c) At higher frequencies it is difficult for tuning inductance to resonate with the charge capacitance.
(d) At higher frequencies, it is almost impossible to get uniform voltage distribution.
Fig.5.8.a. Dielectric Heating

Fig.5.8.b. Equivalent circuit & Vector diagram

Advantages

1. Uniform heat
2. Simple
3. Low running cost
4. Heat generated can be controlled accurately
5. Better Working conditions
6. Less Time of Operation
7. Also called as Capacitance Heating
8. For heating non metallic materials Eg. Wood, Plastic, China Clay, Glass, Ceramics
Applications

1. Manufacturing of synthetics
2. Wood processing

129
3. Foundry course baking
4. Food processing

5.2. ELECTRIC FURNACES


RESISTANCEFURNACES:
5.2.1.REQUIREMENTS OF HEATING ELEMENT MATERIALS

 High resistivity
 High Melting point
 High Mechanical Strength
 High Corrosion resistance
 Low RTC (Resistance Temperature Coefficient)
 Free from oxidation
 Withstand vibrations

5.2.2. COMMONLY USED HEATING ELEMENT MATERIALS

 Nickel Chromium Alloy (Nichrome)

 Nickel Chromium Copper Iron Alloy (Eureka / Constantan)

 Aluminum Chromium Iron Alloy (Kanthal)

5.2.3. RESISTANCE FURNANCE FOR SPECIAL PURPOSES;

The two important resistance ovens are:

1. Air circulation oven

2. Bright annealing furnace

1.Air circulation oven:

In this type, the heat is transferred to the charge by convection currents. These are usually employed
for drawing and hardening steel wire and providing heat treatment to soft metals like aluminum etc.
Gas or Screened air is passed by Blowers or Fans, to avoid radiation and used to circulate the gases or
air. Air circulation from Top to bottom or from bottom to top. The hot gas or air is passed through the
furnace containing charge. The hot gasses circulating in the furnace, heat up the charge uniformly.

130
The direction of flow of air circulation is reversed periodically in order to make the distribution of
heat more uniform.

Application

NITRIDING (Steel after heated by hot air, exposed to Ammonia)

2. Bright annealing furnace

Annealing is the process in which the charge is heated and cooled slowly for elimination of
brittleness. If the cooling is done in air, due to oxygen and water vapours the charge surface is
covered with scale formation, resulting into a dull finish. In this type of furnaces, the charge is heated
in a sealed furnace and the air is discharged during heating through a non return valve. Thus the
cooling is carried out in an air free atmosphere and it keeps the surface of the charge bright and then
air is expelled through a non- return valve.

5.2.4. TEMPERATURE CONTROL OF RESISTANCE FURNACES

1. By varying the number of elements (T∞ R)

2. Change in connections (Series, Parallel)

3. Adding a variable external resistance, in series with the element

4. Changing transformer tappings (V∞ I)

Fig.5.9. Resistance furnace(Only for understanding purpose)

5.2.5. ELECTRIC ARC FURNACES

PRINCIPLE

When a high voltage is applied across 2 electrodes, separated by air gap, the air ion
between gets ionized by electrostatic forces. Electrodes are made of Carbon/Graphite. By this
ionized air current flows through the air gap as in form of sparks. This arc provides a large
quantity of power in a small volume. Concentration of heat develops at high temperatures of
3000 to 3500˚C. Heating chamber is constructed with refractory lining.

131
ADVANTAGES

 Arc furnaces operate with 100% steel scrap, cheaper than pig iron
 Capital cost is lesser than open hearth furnace for same output power (2/3 rd)

TYPES OF ARC FURNACES

1. Direct arc furnace


2. Indirect arc furnace

1. Direct arc furnace


Working principle:

In this type the charge acts as another electrode. There are two carbon or graphite electrodes and
the arc is developed at two places. The arc is directly in contact with the charge and the arc is due to
the current in the charge, therefore the charge is heated to very high temperature. Single arc or 2/3
arcs are established between electrodes. Current flows through the body of charge, develops
heat due to electric resistance.

Fig.5.10 Direct arc furnace

Advantages

1. Very high temperature is obtained

2. More uniform in composition

3. Stirring action takes place.

4. Used for steel production

5. Power factor is 0.8

6. Size of the furnace is from 5 to 10 tones (small), from 50 to 100 tones (large)

132
2. Indirect arc furnace
Working principle:

The arc is produced between two electrodes and the heat is transmitted to the charge by
radiation. Current flows through electrodes & Arc Exists between two electrodes. Heat is
radiated from arc to the charge. It is only of single phase type, because of limitation of
number of electrode. The current does not flow through the charge; hence there is no automatic
stirring. So the furnace is required to be rocked mechanically. Indirect arc furnaces are used for
melting non ferrous metals. Maximum temperature attained by charge is low. Used in iron
industries, where intermittent supply of molten metal is required

Fig.5.11 Indirect arc furnace

Advantages

 Flexibility

 High melting speed

 Economy

 Low metal losses

 Sound castings

Applications

 To make castings of alloy iron for heat resisting, abrasion resisting & similar special purposes

 Suited for non- ferrous castings of copper, bronze, nickel alloy etc,

 Hydraulic & other pressure fittings

3. SUBMERGED ARC FURNACE

These are cylindrical furnaces in which arc is formed between the carbon electrodes and
hearth electrodes. The hearth lining is of magnetite which becomes comparatively good electrical

133
when hot. The number of electrodes taken from the roof depends on the type of supply. One for single
phase, two or four for two phases and three for three phase supply, bottom conductor being connected
to the neutral. Usually 3 phase supply is used for large power requirement. The current from the top
electrode passes through the arc to the charge and returns through the electrode at the bottom of the
charge. In this furnace, uniform heating and mixing of charge takes place. Power is controlled by
varying the distance between the electrodes or by varying the voltage applied to the electrodes. These
furnaces are used for the manufacture of ferroalloy like Ferro - chromo and Ferro -manganese.

5.2.6.a.POWER SUPPLY TO ARC FURNACE

 Small Arc furnaces of ½ tone capacity require power of about 500KW/Tone

 Large furnaces of 50 to 100 tonnecapacity require power of about 200KW/Tone

 Heating effect is directly proportional to square of the current

 High voltage between electrode & charge produces High voltage gradient

 High currents & low voltage keep the electrodes very near to charge

Temperature control of arc furnaces


 By varying resistance of arc.

 By increasing/decreasing distance between gaps (Electrode & Charge)

 Changing transformer tappings.

b. REASONS FOR EMPLOYING HIGH CURRENT & LOW VOLTAGE SUPPLY FOR ARC
FURNACES

 Heating Effect is directly proportional Square of Current. High current gives more heat.
 Electrodes can be kept near to the charge.
 Life of roof refractory is increased.
 Less insulation & more safety

5.2.7. TYPES OF INDUCTION FURNACES

a) Core type induction furnace


1. Direct core type induction furnace
2. Vertical Core (AJAX WYATT) induction furnace
3. Indirect core type induction furnace
b) Coreless induction furnace

1. DIRECT CORE TYPE INDUCTION FURNACE

Working principle:

It consists of an iron core, crucible and primary winding connected to an A.C supply. The
charge is kept in the crucible, which forms a single turn short circuited secondary of transformer.. The
current in the charge is very high in the order of several thousand amperes. The charge is magnetically
coupled to the primary winding. When high current induced in it the charge is melted. Current of

134
Several thousand Amperes melts charge. When there is no molten metal, no current will flow in the
secondary. To start the working of the furnace, molten metal is to be poured or some quantity must be
left in oven

Fig.5.12. Direct core type induction furnace

DRAWBACKS

1. Magnetic coupling between primary & secondary is poor (Power factor will be low)

2. Low frequency supply is essential (Normal frequency causes turbulence in charge)

3. Crucible is of odd shape (Inconvenient from metallurgical point)

4. Inconvenient for intermittent services (Cannot operate when secondary is open)

5. PINCH EFFECT: If current density exceeds 5A/mm2, electromagnetic field interrupts


secondary current(Heating is interrupted)

2. Vertical core (AJAX WYATT) induction furnace

 Improved type of core type induction furnace. It has a vertical channel for the charge,
so the crucible used is also vertical. The principle of operation is that of a transformer in
which the secondary turns are replaced by a closed loop of molten metal. The primary
winding is placed on the central limb of the core. Hence leakage reactance is comparatively
low and power factor is high. An inner wall of furnace is coated with refractory lining of
suitable material. The top of the furnace is covered with an insulated cover which can be
removed for charging. Arrangements are made for tilting the furnace. The molten metal in
the ‘V’ portion acts as a short circuited secondary. When primary is connected to the A.C
supply, high current will be induced in the short circuited secondary. This current melts the
charge. As the furnace is having a narrow V-shape at the bottom, the molten will be
accumulated at the bottom and even a small amount of charge will keep the secondary
completed. Hence chances of discontinuity of the circuit are less.

Fig.5.13.Vertical core (AJAX WYATT) type induction furnace

135
ADVANTAGES

 Magnetic coupling between primary and secondary is better

 Low leakage reactance. So power factor is better

 Discontinuity of circuit is less. (Can used for intermittent services)

 Energy consumption for melting non- ferrous metal is about 300-500 units per tone

 Can be operated with normal frequency

APPLICATIONS

 To melt
 Brass
 Bronze
 Copper
 Zinc
 Tin

3. Indirect core type induction furnace

 Working principle: In this type of furnace by induction principle, Inductively heated element
transfers heat to charge by radiation..It has Iron Core linking with primary & secondary. Secondary
consists of metal container, forming walls of furnace. When the primary winding is connected to the
supply, current is induced in the secondary of the metal container. So heat is produced due to induced
current. This heat is transmitted to the charge by radiation. AB – Bar of special alloy is kept inside
furnace chamber. When furnace attains critical temperature, reluctance of bar increases and cut down
heat. The special alloy will loose its magnetic properties at a particular temperature and the magnetic
properties are regained when the alloy will be cooled.. Thus the temperature of the furnace can be
controlled very effectively.

AB is removable & can be replaced with different critical temperature. Thus temperature control is
effective.

136
Fig.5.14.Indirect core type induction furnace

5.2.8. CORELESS INDUCTION FURNACE

Working principle: Coreless induction furnace also operates on the principle of transformer. In this
furnace there is no core and thus the flux density will be low. Hence for compensating the low flux
density, the current supplied to the primary should have sufficiently high frequency. The flux set up
by the primary winding produces eddy currents in the charge. The heating effect of the eddy currents
melts the charge. Stirring of the metals takes place by the action of the electromagnetic forces.
Coreless furnace may have conducting or non conducting containers.

A coreless induction furnace in which container is made up of conducting material. Charge


container may be conducting (Fig 5.15a) material. The container act as secondary winding and the
charge can have either conducting or non conducting properties. Thus the container forms a short
circuited single turn secondary. Hence heavy current induced in it and produce heat. This heat
produced is transferred to the charge by convection. To prevent the primary winding from high
temperature, refractory linings are provided between primary and secondary windings.

A coreless induction furnace in which the container may be made up of ceramic material (Fig 5.15b)
type and the charge must necessarily have conducting properties. The flux produced by the primary
winding produces eddy currents in the charge.

Eddy current ∞ B2 f2

The heating effect of the eddy currents melts the charge. Stirring action in the metals takes place by
the action of the electromagnetic forces.

Advantages

 Melting time is less


 Power control is possible
 Any Shape of Crucible can be used
 Charging & Pouring is simple
 Automatic Stirring
 Low Erection cost
 Low Running cost
 Absence of dirt, smoke, noise

137
Fig.5.15.Coreless induction furnace

Fig.5.15 c.Coreless induction furnace (Only for understanding purpose)

METHODS OF OBTAINING HIGH FREQUENCY POWER SUPPLY FOR CORELESS


INDUCTION FURNACE

1. Motor Generator set with Salient pole alternator (Suitable for frequencies upto 1000 Hz & for
any output)

2. Motor Generator set with Induction Generator (Suitable for frequencies upto 10,000 Hz & for
output of 1 tone)

3. Vacuum Tube Oscillator (Suitable for frequencies upto 1 million Hz & for small output)

138
5.3 WELDING

Welding is defined as the process of joining similar metals by the application of heat, to form
a permanent joint. Edges of metal pieces are either melted or brought into plastic condition. It
can be done with or without pressure

a. Types of welding

1. Resistance welding
a. Butt welding
i. Upset butt welding
ii. Flash butt welding
b. Spot welding
c. Seam welding
d. Projection welding
2. Arc welding
a. Carbon Arc welding
b. Metal Arc welding
c. Atomic hydrogen Arc welding
d. Inert gas metal arc welding
3. Radiation welding
a. Ultrasonic welding
b. Electron beam welding
c. LASER beam welding

b. REQUIREMENTS OF GOOD WELDING

 Uniformly rippled surface of the weld


 Even contour of the weld
 Even width of the weld
 Absence of surface defects like overlap, undercut, crack & surface porosity
 Absence of internal defects like blow holes, hidden porosity in deposited metal & hidden
crack in weld & work piece

Fig.5.16. Understanding good welding

In fig 5.16 (a), Weld metal has been deposited with correct welding current

1. Toes of bead smoothly change into parent metal and there is thorough penetration

139
2. In fig 5.16 (b), the welding has been done with insufficient current

3. It lacks proper penetration

4. In fig 5.16 (c), the welding has been formed with excess current giving under cutting
at the toe of bead

c. Preparation work for welding

1. Preparing the job


a. Gather the materials, such as welding machine, electrode holder & ground
clamp with lead, electrodes, chipping hammer, wire brush and metal to be
welded
b. Put safety gear, such as welding helmet, jacket, work boots, gloves and safety
glasses
c. Prepare area to be welded. Remove all flammable materials, put the ground
connection on the piece to be welded
d. Set up the machine
e. Use correct electrode, appropriate for DC or AC welding
f. Clean the metal before welding
g. Set the joint. Use clamps and vises to hold the welding
1. Start the weld
a. Strike a welding arc
b. Build up a weld pool
c. Start moving the weld pool across the metal
2. Finish the job
a. Pull the electrode back from metal and allow it to cool
b. Clean the slag
c. Examine the weld
d. Allow the metal to cool.

5.3.1.Resistance welding

Working principle: In resistance welding heavy current is passed through the metal pieces to be
welded. Heat will be developed by the resistance of the work piece. The heat produced for welding is
given by

H = I²Rt

Where H = Heat developed at the contact area.

I = Current in amperes

R = Resistance in ohms

T = time of flow of current

The A.C supply is given to the primary winding of the transformer through a controlled contactor.
Welding transformer used in this is of step down type. The Secondary voltage of the
transformer is 1 to 10 V and current is 50 to 1000 A.
140
. Fig.5.17 . Resistance welding

APPLICATIONS OF RESISTANCE WELDING

 For mass production of


 Sheet metal
 Wire
 Tubes
 Bars
 Boxes
 Cans
 Rods and
 Frames

Types of resistance welding

Butt Welding

Types:

1. Upset butt welding


2. Flash butt welding

A) Upset butt welding

This method is applicable for end to end joints. Pressure is applied in axial direction. Used
for Welding Chains, Pipes, Wires & Rods, Rail ends, Rolled sections of shaft axles. In this
process heat is generated by the contact resistance between two components. In this type of welding
the metal parts to be welded are joined end to end . Sufficient pressure is applied along the axial
direction. A heavy current is passed from the welding transformers which creates the necessary heat at
the joint due to high resistance of the contact area. Due to the pressure applied, the molten metal
forced to produce a bulged joint. This method is suitable for welding pipes, wires and rods.

Fig.5.18 a.Upset Butt Welding

141
B) Flash butt welding

Similar to Butt Welding, but current is applied to metal parts, before they brought
together. When the pieces come together, a flash takes place. Pieces to be welded are
clamped with light pressure. After the welding temperature is reached, power is cut off.
Pressure is applied till the weld gets cooled. Pure & clean weld is applied (As Flash burn
contact surfaces).Less power requirement. All the foreign metals appearing on the contact surface
is burnt due to the flashes. Thus pure and clean weld is obtained

Fig.5.18 b. Flash Butt Welding

142
C) Spot Welding

This method is used to join over lapping sheets or plates of metal at small areas. It provides
mechanical strength only (Welded surfaces are not air/water tight).It can be done on metal
strips of up to 12 mm size. . The welding current flows through electrode tips producing a spot
weld. The welding current and period of current flow depends on the thickness of the plates. It is
used in welding of boxes, cams and frames of automobiles.

Fig.5.19.Spot Welding

D) Seam welding

Used to make a continuous joint on leak proof tanks, drums and radiators. Wheels or
roller type electrodes are used. Seam welding can be defined as series of continuous spot welds.
This process is employed for making continuous joint between two overlapping pieces of sheet metal.
In this type of welding, two wheels or roller type electrodes are used. The electrodes provide
sufficient mechanical pressure and also carry sufficient current for producing continuous welds. In
this type, either the wheels are moved or the metal plates are moved between the wheels. Normally
rotating wheeled electrodes are used

Fig.5.20. Seam Welding

143
E) Projection welding

It is a modified form of spot welding. Forms projections on sheet metal. These projections
are pressed (by heat/pressure) into contact with another sheet. Projection welding consists of
forming slight projections on the sheet of metal. After the projections are formed the raised portions
on one piece are pressed into contact with another piece. The work is held between two copper plate
electrodes and pressure is applied by the movable arm. Current is then passed and good welds at all
points of contacts are made due to flattening flattering out of the projections under heat and pressure.
The surface at the projection must be clean. Used for joining thin sheet metals

Fig.5.21 Projection welding

5.3.2. ELECTRIC ARC WELDING

An electric arc is the flow of current through ionized part. Arc is struck by short circuiting
two electrodes and withdrawing them with small distance. An electric arc is struck by short
circuiting two electrodes and then with drawing them apart by small distance. Current through gap
gives heat for welding. This heat melts part of work piece and filler material and forms joint.
Used for repairing fractured castings, deposition of new metals on worn out parts. Heat
developed in this is also used for cutting the metal

Types of arc welding

1. Carbon arc welding


2. Metal arc welding
3. Atomic Hydrogen arc welding
4. Inert gas metal arc welding
5. Submerged arc welding
1. Carbon Arc welding

DC supply is used is used in this method. Filler material used is the same metal to be welded.
Electrode material is carbon. It is used as negative electrode only, to avoid brittleness. Work piece
acts as positive electrode. Heat from arc forms molten pool. Extra metal is supplied by filler. The
work piece is connected to positive wire. Flux and filter are also used. Filter is made of similar metal
as that of metal to be welded. If the electrode is made `positive then the carbon contents may flow into
the weld and cause brittleness. The heat from the arc forms a molten pool and the extra metal required
to make the weld is supplied by the filter rod. This type of welding is used for welding copper and its
alloy.

144
Fig.5.22 Carbon Arc welding

2. Metal arc welding

AC or DC supply can be used. No need of filler material. In metal arc welding a metal rod of
same material as being welded is used as an electrode. The electrode also serves the purpose of a
filter. Electric supply is connected between electrode and work piece. The work piece is then
suddenly touched by the electrode and then separated from it a little. This results in an arc between the
job and the electrode. A little portion of the work and the tip of the electrode melt due to the heat
generated by the arc. When the electrode is removed the metal cools and solidifies giving a strong
welded joint

Fig.5.2. Metal arc welding

3. Atomic Hydrogen arc welding

In this method of welding two Tungsten electrodes are used in Hydrogen atmosphere with ac
supply.

• The arc is developed between the two electrodes. While heating, molecules of hydrogen are
converted into atomic form. When in contact with cold metal, they recombine and develop high
heat. This temperature facilities high speed welding. This method is usually employed for welding
alloy steel, carbon steel, stainless steel and aluminum.

145
Fig.5.24 Atomic Hydrogen arc welding

4. Inert Gas Metal Arc Welding (Helium Or Argon Arc Welding)

Two Tungsten electrodes are shielded by argon or helium gas. For filling, separate filling
rods are used.AC or DC supply can be used. Arc is formed between tungsten and work piece.
No Oxidation takes place in inert atmosphere. It is used for welding light alloys of copper,
steel and aluminum

Fig.5.25 Inert Gas Metal Arc Welding

5.3.3Comparison between Resistance welding and Arc welding


Sl.No Description Resistance Welding Arc welding

1 Supply AC AC or DC

2 Voltage required Low High

146
3 Heat development due to Flow of current through Arc bw electrode & work
Resistance piece

4 Temperature developed Low High

5 Need of external pressure Needed Not needed

6 Power Factor Low Poor

7 Necessity of filler Not needed Needed


material

8 Suitability for repair Not suitable Suitable


work

9 Application Mass production Used for repair work

5.3.4. RADIATION WELDING

TYPES:

 Ultrasonic welding

 Electron Beam welding

 LASER Beam welding

Ultrasonic Welding

Working principle:

This method is used to joint between similar or dissimilar metals or non-metals by ultrasonic
vibrations using Piezo electric effect. It is produced by using Crystal Oscillator. Crystal
material used in this is Quartz or Barium titanate. Frequency of welding is from 20 to 60
KHz. Work piece is placed between anvil & welding tip. A transducer is used with welding
tip. Vibration produces shear stress in welding tip. This stress melts and welds the metal

Fig.5.26 Ultrasonic welding

147
Advantages:

 Low power requirement

 No smoke produced

 No flux or filler materials

Applications:

 For welding Electronic PCBs,

 For bonding of plastics, bimetals, foils

5.3.5. Electron Beam welding

When an electron travels in a vacuum at high velocity, it produces kinetic energy. This
kinetic energy is converted in to heat energy which joins the metal.

Working principle:

The construction of electron beam welding is shown in fig. when 12 V supply is given to the
tungsten filament, Filament gets heated and emits electrons. Electrons emitted by filament are
accelerated from cathode to anode. Anode is of a metal ring with HVDC of 10 to 150 KV.
Temperature produced is 25000 C. The high velocity electrons are focused on the work piece
through focusing lenses and so heat energy is produced. Thus fills the narrow weld gap
without filler rod.

Advantages:

 Welds are clean


 No porosity, since no air
 Distortion is eliminated
 Fast welding
 Used to weld or cut metal/ceramic/diamond
Fig.5.27. Electron Beam welding

148
Disadvantages:

 High initial cost

 Requires skilled workers

Applications

To weld Titanium, Tungsten, Molybdenum, Stainless steel and Aluminum

5.3.6. LASER Beam welding

LASRES are generating a very intense beam of optical radiation. LASER in


abbreviation is Light Amplification by Stimulated Emission of Radiation

Working principle:

. It generates intense beam of optical radiation. Ruby crystal (Aluminum Oxide coated with
Chromium) is used to generate LASER beam. Ends of Ruby rod are coated with silver, to
form a mirror surface. A hole is provided at one end of the rod, to let out the beam. Capacitor
bank is used for storing electrical energy. A flash tube is wrapped around Ruby rod and
energized by capacitor bank. Flash tube converts electrical energy into Light energy. Light
energy is converted into LASER, by Ruby crystal. It is used to weld small wires with
electronic devices. The laser beam is focused on the metal to be welded through focusing
lens. When this laser beam is concentrated heavy amount of heat is produced on the work
piece. By this high temperature the metal melts and welding is obtained.

Fig.5.28. LASER Beam welding

Advantages:

 Low energy consumption


 Micro miniature welding is possible
 No vacuum is necessary

149
Disadvantages:

 Slow speed of operation


 Not possible to weld above 1.5mm depth
Applications

For Welding Tungsten, Chromium, Nickel, Aluminum and Titanium

5.3.7.ELECTRIC WELDING EQUIPMENTS

1. AC welding equipments

2. DC welding equipments

3. Other equipments

a) Welding Holder
b) Welding Leads
c) Ground Connection
d) Hand Shields

1. AC welding equipments

1. Number of phases used with AC supply

a) Single phase is suitable for obtaining lower current, thinner sections & small
diameter electrodes
b) Two phase is suitable for higher current and thicker jobs
c) Three phase is used, where more than one operator has to work simultaneously

2. Current range is up to 600 amperes

3. One circuit voltage is from 70 to 100 volts

4. Single or multi operator sets are used

5. It has drooping characteristics

6. Small Transformers are of air cooled type

7. Large Transformers are of oil cooled type

ADVANTAGES

1. Not having rotating parts

2. Do not produce noise

3. Occupies less space

4. Less initial cost

150
5. Less maintenance cost

6. Possess High efficiency

7. Consume less energy per unit weight of deposited metal

8. High no load voltage

DISADVANTAGE

• Melting rate of electrode cannot be controlled

2. DC welding equipments

1. AC Transformer with Silicon or Selenium Rectifier (or) DC Generator driven by AC


Motor as a prime mover (or) DC Generator driven by Petrol/Diesel engine as a prime
mover can be used.

2. Current range is up to 600 amps

3. One circuit voltage is from 45 to 75 volts

4. Drooping, Slightly drooping or flat characteristics

Fig.5.29.DC welding equipment

Prime Mover

Fig.5.30.Characteristics of DC welding equipments

151
ADVANTAGES

 At higher arc currents, it gives smoother arc


 No arc blow problem
 Once established, the arc can be easily maintained and controlled
 It is suitable for welding thicker sections
3. Welding Holder

1. Jaws of holder remain under spring pressure


2. Jaws may or may not be insulated
3. Available range from 100 to 500 A
4. They are provided with a heat shield
5. It should be Light & Sturdy
6. It should hold electrode easily
7. It’s handle should possess high resistance to heat and Electricity

5.3.8. COMPARISON BETWEEN AC AND DC WELDING

152
REVIEW QUESTIONS -Part A

1. Classify heating methods based on temperature range


2. State the types of electric heating
3. What is arc heating? State its types
4. State the types of high frequency electric heating
5. State commonly used heating element materials
6. State the methods used for temperature control of resistance furnaces
7. Write notes on power supply to arc furnaces
8. State the methods used for Temperature control of arc furnaces
9. State the reasons for employing high current & low voltage supply for arc furnaces
10. State the types of induction furnaces
11. Define welding
12. State the types of resistance welding
13. State the types of arc welding
14. State the types of radiation welding

Part B QUESTIONS

1. State the advantages of electric heating


2. Explain modes of heat transfer
3. Explain infra red heating
4. Explain induction heating
5. State the requirements of heating element materials used in resistance furnace
6. Write notes on Air circulation oven
7. Write notes on Bright annealing furnace
8. State the principle and advantages of electric arc furnaces
9. State the requirements of good welding
10. Write notes on preparation work for welding
11. What is resistance welding? State its applications.
12. Compare Resistance welding and Arc welding
13. Compare AC and DC welding

Part C QUESTIONS

1. Draw and explain direct & indirect resistance heating with suitable sketches
2. Explain the working of an induction stove with a sketch. State its merits & demerits
3. Explain eddy current heating with a sketch. State its applications.
4. Explain dielectric heating with a sketch. State its applications.
5. Draw and explain direct & indirect arc furnaces with suitable sketches
6. Draw and explain direct core type induction furnace with a sketch.
7. Draw and explain Vertical Core (AJAX WYATT) induction furnace with a sketch.
8. Draw and explain indirect core type induction furnace with a sketch.
9. Draw and explain Coreless induction furnace with a sketch.
10. State the types of Butt welding. Explain them with sketches.
11. Explain the following with sketches.
a. Spot welding
b. Seam welding
c. Projection welding
12. Explain the following with sketches.

153
a. Carbon arc welding
b. Metal arc welding
13. Explain the following with sketches.
a. Atomic Hydrogen arc welding
b. Inert gas metal arc welding
14. Explain ultrasonic welding with a sketch.
15. Explain electron beam welding with a sketch.
16. Explain LASER Beam welding with a sketch.
17. State and explain electric welding equipments.