SAFETY DATA SHEET

1. PRODUCT IDENTIFICATION AND COMPANY INFORMATION


1.1. Product identifiers
Product Name: DLS 970A
1.2. Relevant identified uses of the substance or mixture and uses advised against
Product Class: ORGANIC DYE – METAL COMPLEX, SUBSTITUTED AMINIUM
Identified uses: Laboratory chemicals, Manufacture of substances
1.3. Details of the supplier of the safety data sheet
Company: Crysta-Lyn Chemical Company, Inc.
6 Emma Street
Binghamton, NY 13905 USA
Tel: 1-607-770-6096 Fax: 1-607-729-3322
1.4. Emergency telephone number
For Chemical Emergency, Spill, Leak, Fire, Exposure, or Accident Call CHEMTREC Day or Night
DOMESTIC NORTH AMERICA 800-424-9300
INTERNATIONAL, CALL 703-527-3887 (collect calls not accepted)

2. HAZARDOUS IDENTIFICATION
2.1. Classification of the substance or mixture
To the best of our knowledge, the toxicological properties of this chemical have not been thoroughly
investigated. Use appropriate procedures and precautions to prevent or minimize exposure.
GHS Classification in accordance with 29 CFR 1910 (OSHA HCS)
Skin irritation (Category 2), H315
Eye irritation (Category 2A), H319
Specific target organ toxicity – single exposure (Category 3), Respiratory system, H335
Chronic aquatic toxicity (Category 4), H413
For the full text of the H-Statements mentioned in this Section, see Section 16

2.2. GHS Label elements, including precautionary statements


Pictogram

Signal word Warning

H315 Causes skin irritation.


H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H303 May be harmful if swallowed.
H413 May cause long lasting harmful effects to aquatic life.
[Prevention]
P261 Avoid breathing dust.
P264 Wash skin thoroughly after handling
P271 Use only outdoors or in a well-ventilated area
P273 Avoid releases to the environment
P280 Wear protective glove/eye protection/face protection
P285 In case of inadequate ventilation wear respiratory protection
[Response]
P301+P312 IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell

DLS 970A Revision Date: February 6, 2017 Page 1 of 8


P302+P352 IF ON SKIN: Wash with soap and water
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for
breathing
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact
lenses, if present and easy to do. Continue rinsing
P312 Call a POISON CENTER or doctor/physician if you feel unwell.
P332+P313 If skin irritation occurs: Get medical advice/ attention.
P337+P313 If eye irritation persists: Get medical advice/ attention.
P362 Take off contaminated clothing and wash before reuse.
[Storage]
P403+P233 Store in a well ventilated place. Keep container tightly closed.
P405 Store locked up.
[Disposal]
P501 Dispose of contents/ container to an approved waste disposal plant
2.3. Hazards not otherwise classified (HNOC) or not covered by GHS
No data available.

3. COMPOSITION/INFORMATION ON INGREDIENTS
3.1. Substances
Substance: DLS 970A
Synonyms: No data available
Chemical name: Proprietary
CAS-No.: Proprietary
EC-No.: Proprietary
Hazardous components
Component Classification Concentration
DLS 970A (dye complex contains 18% Skin Irrit. 2 95 - 100 %
Antimony) Eye Irrit. 2A
STOT SE 3
Aquat Chron 4,
H315, H319, H335, H413
For the full text of the H-Statements mentioned in this Section, see Section 16.

4. FIRST AID MEASURES


4.1. Description of first aid measures
General advice:
Consult a physician. Show this safety data sheet to the doctor in attendance. Move out of dangerous area.
For inhalation:
Remove victim to a well-ventilated area. Give oxygen or artificial respiration as required. Consult a
physician.
For skin contact: Remove contaminated clothing and shoes. Wash thoroughly with mild soap and warm
water. Consult a physician if there is persisting irritation. Wash clothing before reuse.
For eye contact: Contact with eyes can cause irritation. Flush with copious amounts of water for at least
fifteen minutes. Consult a physician.
For swallowing: Never give anything by mouth to an unconscious person. Rinse mouth thoroughly with
water. Consult physician or poison control center immediately. Treat symptomatically. Be prepared to
provide the attending physician a copy of this document.
Special notes to attending physician: There is no specific antidote. Treatment of overexposure should
be directed at control of symptoms and the clinical condition.
DLS 970A Revision Date: February 6, 2017 Page 2 of 8
4.2. Most important symptoms and effects, both acute and delayed
Persons with a history of skin sensitization problems should be careful and follow precautionary
procedures when working in an area where this material is used. Chronic effects are unknown.
4.3. Indication of any immediate medical attention and special treatment needed
No data available

5. FIRE-FIGHTING MEASURES
5.1. Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam dry chemicals or carbon dioxide.
5.2. Special hazards arising from the substance or mixture
Hazardous combustion products include: Carbon oxides, nitrogen oxides (NOx)
Dispose of run-off from firefighting in accordance with federal, state and local waste disposal ordinances.
5.3. Special protective equipment and precautions for fire-fighters
Exposure to decomposition products may be a health hazard.
Wear self contained breathing apparatus (SCBA) for firefighting if necessary.
Cool closed containers exposed to fire with water spray.

6. ACCIDENTAL RELEASE MEASURES


6.1. Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
6.2. Methods and materials for containment and cleaning up
Avoid dusting. Clean up spillages, transfer to a container for disposal. Wash the spillage area clean,
washing material must be prevented from entering surface water drains.
Waste disposal: This material must be disposed within accordance with federal, state, and local
ordinances.
6.3. Environmental precautions
Do not let product enter drains, sewers or watercourses.

7. HANDLING AND STORAGE


7.1. Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.
Handle and open container with care. Wear suitable protective gloves, clothing and eye/face protection.
When using do not eat, drink, or smoke.
Good housekeeping standards are essential to avoid the exposure of all personnel.
7.2. Conditions for safe storage, including any incompatibles
Keep containers tightly closed when not in use.
Store in a dry, well ventilated area away from sources of heat, ignition and direct sunlight.
Store separately from strong oxidizing agents, strong acids and bases
7.3. Specific end use(s)
Apart from the uses mentioned in Section 1.2 no other specific uses are stipulated.

8. EXPOSURE CONTROLS AND PERSONAL PROTECTION


8.1. Control parameters
There are no control parameters established for this material.

DLS 970A Revision Date: February 6, 2017 Page 3 of 8


Components of the dye complex with workplace control parameters.
Antimony (CAS 7440-36-0, EC 231-146-5)
ACGIH: 0.5 mg/m3 TWA
NIOSH: 0.5 mg/m3 TWA
OSHA Z1: 0.5 mg/m3 TWA
8.2. Exposure controls
Appropriate engineering controls: Use adequate general or local exhaust ventilation to keep airborne
concentrations below the permissible exposure limits. If these are not sufficient to maintain
concentrations of vapors below the relevant exposure limits, suitable respiratory protective equipment
should be worn.
Personal protective equipment
Respiratory protection: If respirators are needed, use a respirator with APF of at least 10 type N95 (US)
or type P1 (EN 143). Use respirators and components tested and approved under appropriate government
standards such as NIOSH (US) or CEN (EU)
Protective gloves: Wear latex, rubber, or nitrile gloves to minimize skin contamination.
Eye protection: Wear safety glasses with side shields conforming to EN 166.
Skin and body protection: Choose body protection according to the amount and concentration of
material being used.
Additional safety equipment: Safety shower and eye wash should be available
Hygienic safety practices: Wash hands after handling compounds and before eating, using tobacco
products or using the washroom and at the end of the day.

9. PHYSICAL AND CHEMICAL PROPERTIES


9.1. Information on basic physical and chemical properties

Form: Powder Ignition temperature: No data available


Color: Green Flammability No data available
Odor: None Upper explosion limit: No data available
Odor threshold: No data available Lower explosion limit: No data available
pH: No data available Vapor pressure: No data available
Melting point: >102°C Vapor density: No data available
Decomposition temp. >300°C Relative density: No data available
Boiling point: No data available Water solubility: Insoluble
Flash point: No data available Viscosity: No data available
Evaporation rate: No data available Partition coefficient: No data available
n-octanol/water

9.2. Other safety information


No data available.

10. STABILITY AND REACTIVITY


10.1. Reactivity
Hazardous polymerization will not occur
10.2. Chemical stability
Stable under recommended storage conditions

DLS 970A Revision Date: February 6, 2017 Page 4 of 8


10.3. Possibility of hazardous reactions
No data available
10.4. Conditions to avoid
Dust generation
10.5. Incompatible materials
Avoid contact with strong acids, strong bases, strong oxidizing agents.
10.6. Hazardous decomposition products
In a fire, hazardous decomposition products such as smoke, carbon oxides, and nitrogen oxides (NOx)
may be produced.

11. TOXICOLOGICAL INFORMATION


11.1. Information on toxicological effects
Toxicological studies of this compound have not been done.
Acute toxicity
Component Information
Antimony (CAS 7440-36-0, EC 231-146-5)
Inhalation, rat: LC50 No data available
Oral, rat: LD50 7,000 mg/kg
Dermal, rabbit: LD50 No data available
Intravenous, rat: LD50 No data available
Eyes, rabbit No data available
Routes of exposure:
Primary routes of exposure are inhalation and skin contact.
Symptoms related to exposure:
Inhalation exposure may result in respiratory irritation. Skin contact may result in redness, pain or dry
skin. Eye contact may result in redness or pain.
Potential health effects:
Skin and eye contact may result in redness or pain.
Skin corrosion/irritation:
No data available.
Serious eye damage/eye irritation:
No data available.
Respiratory or skin sensitization:
No data available.
Germ cell mutagenicity:
No data available.
Carcinogenicity:
No component of this product, present at levels greater than or equal to 0.1% is listed by ACGIH, IARC,
NTP, or OSHA
Reproductive toxicity:
No data available.
Specific target organ toxicity – single exposure:
No data available.
Specific target organ toxicity – repeated exposure:
No data available

DLS 970A Revision Date: February 6, 2017 Page 5 of 8


Aspiration hazard:
No data available.
Additional Information:
RTECS: Not available
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.

12. ECOLOGICAL INFORMATION


12.1. Ecotoxicity
No data available.
12.2. Persistence and degradability
No data available.
12.3. Bioaccumulative potential
No data available.
12.4. Mobility in soil
No data available.
12.5. Results of PBT and vPvB assessment
PBT/vPvp assessment not available as chemical safety assessment not conducted
12.6. Other effects
Do not allow to enter drains, sewers or watercourses.

13. DISPOSAL CONSIDERATIONS


13.1. Waste treatment methods
Observe all federal, state and local regulations when disposing of this substance. Do not empty into
drains, sewers or watercourses.
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed
professional waste disposal service to dispose of this material. Dissolve or mix the material with a
combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.

14. TRANSPORT INFORMATION


14.1. DOT (US)
Not dangerous goods
14.2. IMDG
Not dangerous goods
14.3. IATA
Not dangerous goods

15. REGULATORY INFORMATION


15.1. US Federal
15.1.1. TSCA: This material is listed on the TSCA inventory.
15.1.2. OSHA Hazards: Unknown

DLS 970A Revision Date: February 6, 2017 Page 6 of 8


15.1.3. SARA :
SARA 302 Components: To the best of our knowledge this product does not contain chemicals at levels
which require reporting under this statute.
SARA 311, 312 Hazards: No data available
SARA 313 Components: This material the following chemical component and is subject to the reporting
requirements of Section 313 of the Emergency Planning and Community Right to Know Act of 1986 and
40CFR372:
Antimony Compounds
15.2. State
New Jersey Right to Know Components (>1%): Antimony
Pennsylvania Right to Know Components (>1%): Antimony
CALIFORNIA PROPOSITION 65: This product does not contain any chemicals known to the State of
California to cause cancer, birth defects, or any other reproductive harm.
15.3. Other
REACH: Listed
NDSL: Listed

16. OTHER INFORMATION


Full text of H-Statements referred to under sections 2 and 3.
Skin Irrit. Skin Irritation
Eye Irrit. Eye Irritation
STOT SE Specific target organ toxicity – single exposure
Aquat Chron Chronic aquatic toxicity
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H303 May be harmful if swallowed.
H413 May cause long lasting harmful effects to aquatic life.

HMIS® Classification: (scale 0 – 4) NFPA Rating (scale 0 - 4)


HEALTH 2
FLAMMABILITY 0
REACTIVITY 0
PERSONAL
PROTECTION

Crysta-Lyn Chemical Company, Inc. makes no warranty, expressed or implied, as to the accuracy or reliability of
information contained herein, except that such information is, to the best of our knowledge and belief, accurate as
of the date indicated on this document. Crysta-Lyn Chemical Company, Inc. is not responsible for any damage or
injury resulting from abnormal use, from any failure to follow appropriate practices or from hazards inherent in
the nature of this product.

DLS 970A Revision Date: February 6, 2017 Page 7 of 8


Final determination of suitability of any material is the sole responsibility of the user. All materials may present
unknown health risks or hazards and should be used with caution. Crysta-Lyn Chemical Company, Inc. urges the
customer receiving this SDS to study it carefully to become aware of the hazards, if any. In the interest of safety,
you should notify your employees, agents, contractors, etc. of the information on this sheet and make it available
to anyone using this product and request your customers to inform their employees, customers and agents as well.
The information contained in this SDS is based on the present state of knowledge and current national legislation.
It provides guidance on health, safety and environmental aspects of this product and should not be construed as
any guarantee of technical performance or suitability for particular applications.

DLS 970A Revision Date: February 6, 2017 Page 8 of 8