Nothing Special   »   [go: up one dir, main page]

Determination of Grafting Degree of Maleic Anhydride On PP

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

20.2.

2019

Material Report
DETERMINATION OF GRAFTING DEGREE OF MALEIC ANHYDRIDE ON PP

The aim of this report is, to show that our Methods of Grafting Degree Determination are versatile and
accurate.

MATERIALS USED

For this report, we used scrap PP that was grafted with MAH at Graft Polymer. Matrix material was provided
by Customer.

TESTS PERFORMED

For the determination of grafting degree, we used:

 Fourier Transformation Infrared Spectrometer (FTIR, picture on


right)
 Back Titration with KOH and HCl

We tested two samples:

 Stored in LDPE bags, as prepared – FTIR Only


 Chemically purified samples -

Purification was performed in two steps:

 Dissolving grafted polymer


 Elimination of unreacted MAH

GRAFT POLYMER D.O.O. GRAFT POLYMER UK LTD


Emonska Cesta 2, Ljubljana Slovenia Central Working Victoria Eccleston Yards 25,
Company Num. 8056200000, VAT. SI 30561345 Eccleston Pl, London, UK, SW1W 9NF.
Phone Num. +38640867937 Company Num. 10776788, VAT. 281712016
office@graftpolymer.com www.graftpolymer.com
Material Report

PROCESS

We dissolve 5 gr of PP-g-MAH in boiling xylene (Isomeric mixture) in a reflux (left)


After that we let it cool (right)

The solution is precipitated using acetone – acetone also dissolves unreacted MAH away (left)

The sample is dried in a fume hood for 3 hours and in an oven at 60°C for 2 hours (right)

GRAFT POLYMER D.O.O. GRAFT POLYMER UK LTD


Emonska Cesta 2, Ljubljana Slovenia Central Working Victoria Eccleston Yards 25,
Company Num. 8056200000, VAT. SI 30561345 Eccleston Pl, London, UK, SW1W 9NF.
Phone Num. +38640867937 Company Num. 10776788, VAT. 281712016
office@graftpolymer.com www.graftpolymer.com
Material Report

After the sample is dried, we dissolve 1 g again in boiling xylene and add 5 mL of the base KOH (0,1 M)

Reaction with anhydride and KOH occurs, using up all anhydride groups

We added KOH in excess, in order to titrate it with HCl

We add 2 drops of the indicator phenolphthalein to the solution – it is pink because the solution is basic

We titrate the leftover KOH with HCl (0,05 M)

Titration is finished when the solution is colorless

GRAFT POLYMER D.O.O. GRAFT POLYMER UK LTD


Emonska Cesta 2, Ljubljana Slovenia Central Working Victoria Eccleston Yards 25,
Company Num. 8056200000, VAT. SI 30561345 Eccleston Pl, London, UK, SW1W 9NF.
Phone Num. +38640867937 Company Num. 10776788, VAT. 281712016
office@graftpolymer.com www.graftpolymer.com
Material Report

RESULTS

FTIR RESULTS

PURIFIED SAMPLE

SAMPLE FROM STORAGE

On the above picture, we can see the comparison between “raw” (Purple spectra) and purified (Red spectra)
samples. Maleic anhydride is seen in the area of 1850 cm-1 and 1780 cm-1, according to the x axis. The relevant
area is circled.

 Calculated MAH on the sample from storage is: 1,97% MAH (Including unreacted MAH)
 Calculated MAH on the purified sample is: 1,46% MAH (No unreacted MAH)

TITRATION RESULTS

For the determination of grafting degree, we used the following formula:

𝑐(𝐾𝑂𝐻)∗𝑉(𝐾𝑂𝐻 𝑙𝑒𝑓𝑡𝑜𝑣𝑒𝑟)∗𝑀(𝑀𝐴𝐻)
𝐺𝐷 (𝑀𝐴𝐻 ) = = 1,598%
𝑚(𝑠𝑎𝑚𝑝𝑙𝑒)

c (KOH) – KOH Concentration [mol/L]

V(KOH leftover) - KOH, that wasn’t used for neutralizing HCl [L]

M(MAH) – Molar mass of grafted MAH [=99,07 g/mol]

m(sample) – mass of the purified polymer sample [g]

GRAFT POLYMER D.O.O. GRAFT POLYMER UK LTD


Emonska Cesta 2, Ljubljana Slovenia Central Working Victoria Eccleston Yards 25,
Company Num. 8056200000, VAT. SI 30561345 Eccleston Pl, London, UK, SW1W 9NF.
Phone Num. +38640867937 Company Num. 10776788, VAT. 281712016
office@graftpolymer.com www.graftpolymer.com
Material Report

CONCLUSIONS

 Grafting degree, measured with FTIR before purification is higher than that of purified sample, which

means that 0,51% of MAH was unreacted

 By purifying the sample, we determined the grafting degree of the sample to be around 1,5%

 The difference between the methods is only around 0,138%

 When increasing the number of samples, the deviation grows smaller

 FTIR and titration are COMPARABLE METHODS

GRAFT POLYMER D.O.O. GRAFT POLYMER UK LTD


Emonska Cesta 2, Ljubljana Slovenia Central Working Victoria Eccleston Yards 25,
Company Num. 8056200000, VAT. SI 30561345 Eccleston Pl, London, UK, SW1W 9NF.
Phone Num. +38640867937 Company Num. 10776788, VAT. 281712016
office@graftpolymer.com www.graftpolymer.com
Material Report

CONTACTS

MANAGEMENT

CEO/CTO | Victor Bolduev +386 40 534 739

Executive Director / CMO | Pavel Kobzev +386 40 867 937

Pavel@graftpolymer.com

GRAFT POLYMER D.O.O (OFFICE)

Emonska Cesta 8, Ljubljana Slovenia.

Company Num. 8056200000,

VAT. SI 30561345

Tel +386 1 777 6561

office@graftpolymer.com

www.graftpolymer.com

GRAFT POLYMER D.O.O (PRODUCTION/WAREHOUSE)

Mejaceva ulica 2, 1353 Borovnica Slovenia

Company Num. 8056200000,

VAT. SI 30561345

office@graftpolymer.com

www.graftpolymer.com

GRAFT POLYMER (UK) LTD

Central Working Victoria Eccleston Yards 25,

Eccleston Pl, London, UK, SW1W 9NF.

Company Num. 10776788, VAT. 281712016

www.graftpolymer.com

GRAFT POLYMER D.O.O. GRAFT POLYMER UK LTD


Emonska Cesta 2, Ljubljana Slovenia Central Working Victoria Eccleston Yards 25,
Company Num. 8056200000, VAT. SI 30561345 Eccleston Pl, London, UK, SW1W 9NF.
Phone Num. +38640867937 Company Num. 10776788, VAT. 281712016
office@graftpolymer.com www.graftpolymer.com

You might also like