Diesel Generator Set V28 Series: Lowest Life Cycle Cost
Diesel Generator Set V28 Series: Lowest Life Cycle Cost
Diesel Generator Set V28 Series: Lowest Life Cycle Cost
V28 series
Specification sheet
480-500 kWe, 600-625 kVA Prime
© 2009 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy
working for you.” are trademarks of Cummins Power Generation. Other company product
names may be trademarks or service marks of others. Specifications are subject to change
without notice.
PGBU/CIL/005/V28 600-625 kVA/Jaksons/February 2009/Qty.
Alternator: Stamford brushless alternator - Engine protection for low lube
oil pressure, high coolant
- Self-excited, self regulated
temperature (alarm and
- Class ‘H’ insulation
shutdown)
- Salient pole revolving field
- Alternator protection
- Single bearing
parameters like under voltage,
- Digital automatic voltage regulator
over voltage, over frequency,
over current, under frequency
Accessories: (alarm and shutdown)
- Silencer suitably optimized to meet stringent sound emission - Relay drivers for remote annuciations
standards laid down by MOEF / CPCB - Cyclic cranking
- Base rail with integral fuel tank is provided with drain plug, - Auto/ manual start/ stop
air vent, inlet and outlet connection, level indicator, manhole etc. - Alternator trim adjustment from the front key pad
- Integral fuel tank of 926 litres capacity - Model specific calibration from the front key pad
- 2 x 12 V dry, uncharged batteries with connecting leads and - Speed bias or raise/ lower inputs are provided for paralleling
terminals - Remote monitoring capability through separate interface modules
- 6 configurable discrete outputs
Acoustic enclosure: - 2 configurable discrete inputs
- Smooth transition to rated speed
- Specially designed to meet stringent MOEF/ CPCB norms of - Smart start algorithm
75 dBA @ 1mtr at 75% load under free field conditions - Housed in a NEMA 3R/IP 53 non-metallic enclosure
- Designed to have optimum serviceability - Operates within a wide temperature range (0-60 degrees C) and
- Air inlet louvers specially designed to operate at rated load humidity up to 95%
even at 50 deg. C enclosure temp.
- Made on special purpose CNC machines for consistency Control panel: Powder coated control panel manufactured
in quality and workmanship with 14 / 16 gauge CRCA sheet provides:
- Powder coated for long lasting service life and superior finish
- With UV resistant powder coating, can withstand extreme - MCCB / ACB of suitable rating with overload and short circuit
environments protection
- Use of stainless steel hardware - Voltmeter and Ammeter with selector switch
- Insulation material meets exacting IS 8183 specs for better - KW / PF meters
attenuation - Frequency meter
- KWh meter
- Indicating lamps for “Load On” and “Set Running”
- Current transformers
- Aluminium busbars of suitable capacity with incoming and
outgoing terminations
- Instrument fuses duly wired and ferruled
Optionals
Engine: Heavy duty air cleaner, lube oil / coolant heater with
thermostatic switch
Alternator: Thermistors, PMG excitation, space heater
Control panel: "PowerCommand ® Control Panel (PCC 3100) "
for microprocessor based governing, regulation, metering,
monitoring and auto synchronising control system. AMF control
panel, battery charger, remote/ auto start panel, auto/ manual
PowerCom® features: synchronizing panel and audio/ visual annunciation for faults.
www.cumminsindia.com
Our energy working for you.TM
© 2009 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy
working for you.” are trademarks of Cummins Power Generation. Other company product
names may be trademarks or service marks of others. Specifications are subject to change
without notice.
PGBU/CIL/005/V28 600-625 kVA/Jaksons/February 2009/Qty.
Technical data
Generator set specifications
Model CJ 600 D5 P CJ 625 D5 P
Prime Power Rating kVA 600 625
Output Voltage and Frequency 415 Volts, 50 Hz 415 Volts, 50 Hz
Power Factor 0.8 (lag) 0.8 (lag)
No. of phases 3 phase 3 phase
Engine specifications
Make Cummins Cummins
Model VTA 28 G3-I VTA 28 G5-I
No. of cylinders 12 ‘Vee’ 12 ‘Vee’
Aspiration Turbocharged-Aftercooled Turbocharged-Aftercooled
Bore x Stroke 140 mm x 152 mm 140 mm x 152 mm
Displacement 28 ltrs 28 ltrs
Output - Prime 530 kWm 560 kWm
Fuel consumption @ 75% load with Radiator & Fan 96.3 ltr/hr 98.6 ltr/hr
Fuel consumption @ 100% load with Radiator & Fan 123.9 ltr/hr 131 ltr/hr
Typical lube oil consumption @ 100% load 0.15 ltr/hr 0.15 ltr/hr
Total wet weight ( engine + radiator and fan) 3354 kg 3354 kg
Length x Width x Height (engine) 2240 x 1265 x 1820 mm 2240 x 1265 x 1820 mm
Compression Ratio 14.1 : 1 13.5:1
Piston Speed 7.6 m/s 7.6 m/s
Governor / Class Electronic / A1 Electronic / A1
Lubricating oil sytem capacity 95 ltrs 95 ltrs
Coolant capacity (engine + radiator) 250 ltrs 250 ltrs
Combustion air intake @ 100% load (+/- 5%) 42.5 m 3/min 46.1 m 3/min
Fan air flow across radiator 1133 m 3/min 1198.13 m 3/min
Exhaust Temperature 453 oC 457 oC
Battery Capacity / Rating 180 AH, 2 X 12 V 180 AH, 2 X 12 V
Alternator specifications
Make Stamford Stamford
Frame size / Model No. HC5E HC5F
Voltage Regulation + 1.0% + 1.0%
Insulation Class H Class H
Standard Enclosure IP 23 IP 23
Winding Pitch 2 / 3 Pitch 2 / 3 Pitch
Stator Winding Double layer lap Double layer lap
Rotor Dynamically balanced Dynamically balanced
Wave form distortion No load < 1.5%, non distorting No load < 1.5 %, non distorting
balanced linear load < 5 % balanced linear load < 5 %
Telephone Interference Factor Better than 50 Better than 50
Total Harmonic Factor Better than 2% Better than 2%
Conformance standards
IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046
Rating definitions
Prime Power (PRP): - Fuel consumption data is based on diesel having specific
Applicable for supplying power to varying electrical load for gravity of 0.85 and conforming to IS:1460
unlimited hours. Prime Power (PRP) is in accordance with - Oil consumption data is based on oil having specific gravity of
ISO 8528. Ten percent overload capability is available in 0.89 and meeting CF4 API categories
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. - Fuel consumption tolerance is +5%
www.cumminsindia.com
Our energy working for you.TM
© 2009 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy
working for you.” are trademarks of Cummins Power Generation. Other company product
names may be trademarks or service marks of others. Specifications are subject to change
without notice.
PGBU/CIL/005/V28 600-625 kVA/Jaksons/February 2009/Qty.
Typical enclosed genset dimensions*
Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Weight (kgs.) (Dry)
CJ 600 D5 P 600 kVA 7000 2500 2925 10500
CJ 625 D5 P 625 kVA 7000 2500 2925 10500
© 2009 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working
for you.” are trademarks of Cummins Power Generation. Other company product names may be trademarks or service marks of others. Specifications are subject to change without notice.
PGBU/CIL/005/X 15-25 kVA/Jakson/February 2009/Qty.