TEST REPORT Nº 2418/0482 Page 1 of 8

Test site ................................. : Laboratory of Electrical Testing


Test date ................................ : 2018 / 06 / 26 to 2018 / 07 / 05
Client ...................................... : AMETSIS, S.L.
Address.................................. : C/ Ciudad de frías 16
................................................ 28021 Madrid, Spain

Equipment/sample tested .... : ALARM HANDLE FOR RAILWAY APPLICATION


State and reception date ...... : CORRECT, 2018 / 06 / 26
Supplier ................................. : AMETSIS, S.L.
Trade-mark ............................ : AMETSIS
Model ..................................... : LM11944/450
Serial number ........................ : 18/001
Reference .............................. : SIRPAD-W
Ratings................................... : 72 V d.c.

Standards applied................... : - UNE-EN 50121-3-2:2017 (*)


IEC 61000-6-4:2018
UNE-EN 61000-4-2:2010
UNE-EN 61000-4-3:2007+A1:2008+A2:2011
UNE-EN 61000-4-4:2013
UNE-EN 61000-4-5:2015
UNE-EN 61000-4-6:2014
(*) Standard out of the Laboratory scope ENAC Nº5/LE011

Results ................................... : Results obtained refer to the sample tested which is the subject of this Report,
considering worst case values from tests and verifications carried out.
Measurement uncertainties associated with variables determined during tests
are available from the Laboratory at Customer’s request.

Conclusions .......................... : Based upon results obtained the tested sample COMPLIES with the
requirements indicated in the applied test specifications. For evidence of
applicant, this documents is issued in Madrid,

Madrid, 09 July of 2018

Tested by Tested by Approved by


EMC Test Engineer EMC Laboratory Reviewer Technical Manager of Test Laboratory

RUBÉN BELLO TORRALBO JAVIER MORGADO DURÁN FERNANDO MONTES CLAVER


This test report, consisting of 8 pages, with Annex of 8, cannot be copied partially without the written consent of the Director of SGS Tecnos, S.A.
SGS Tecnos, S.A. C/ Trespaderne, 29 - Edif. Barajas 1 ( 28042 MADRID)
LABORATORIO DE ENSAYOS ELÉCTRICOS Tfno: 913-138-000 Fax: 913-138-093
TEST REPORT Nº 2418/0482 Page 2 of 8

MEASUREMENTS OF CONDUCTED RFI INTERFERENCES

STANDARD APPLIED: UNE-EN 50121-3-2 (Specifications)


UNE-EN 55016-2-1 (Test method)

1.- General data:

Frequency range (MHz) ......................................... : 0,15 to 30


Measurement Indicator ........................................ : PEAK (blue)
EUT Supply voltage (V) ......................................... : 72 V d.c.
Test site .................................................................. : EMC Shielded Chamber, SGS Tecnos, Madrid, Spain
Ports tested ............................................................ : Mains supply terminals (+ & -)

MAIN TEST EQUIPMENT:


 EMI Receiver Rohde&Schawarz / ESR26
 Artificial network (LISN) Rohde&Schawarz / ESH2-Z5
 Pulse limiter R/S ESH3-Z2

2.- Limits applicable to EUT (Table 1 of the Standard UNE-EN 50121-3-2):

FREQUENCY RANGE ADMISSIBLE LEVELS dB (V)


(MHz) QUASI – PEAK VALUE

0,15 to 0,5 99
0,5 to 30 93

3.- Test conditions:

- Supply lines checked: Positive and negative terminals power supply.


- Equipment in continuous operation, normal mode (switch not activated) and emergency mode (cycles of
activation and remote deactivation of the switch).

4.- Graphs:

The pages 2 and 3 of Annex shows the resulting graphs obtained during the tests.

5.- Frequencies study and evaluation:

Levels measured did not exceed the limits established by the Standard in the test conditions above
specified. The sweeps displayed in the Annex graphs show that all the QUASIPEAK values are at levels
below the indicated limits, therefore the sample is IN CONFORMITY with the requirements indicated in the
applied test specifications.
TEST REPORT Nº 2418/0482 Page 3 of 8

MEASUREMENTS OF RADIATED RFI INTERFERENCES

STANDARD APPLIED : UNE-EN 50121-3-2 (Specifications)


IEC 61000-6-4 (Specifications)
CISPR 16-2-3 (Test method)

1.- General data:

Frequency sweep (MHz)........................................ : 30 to 6000


Measurement Indicator ........................................ : PEAK (green) value
EUT Supply voltage (V) ......................................... : 72 V d.c.
Test site .................................................................. : EMC Full Anechoic Room, SGS Tecnos, Madrid, Spain
Ports tested ............................................................ : Envelope of EUT

MAIN TEST EQUIPMENT:


 EMI Receiver Rohde&Schwarz / ESR26
 Antenna Schwarzbeck / VULB 9162

2.- Limits applicable to EUT (Clauses 3.3 and 3.4 of Table 3 of the Standard IEC 61000-6-4:2018):

ADMISSIBLE LEVELS ADMISSIBLE LEVELS ADMISSIBLE LEVELS


FREQUENCY RANGE FOR MEASUREMENT FOR MEASUREMENT FOR MEASUREMENT
(MHz) DISTANCE OF 3 m DISTANCE OF 3 m DISTANCE OF 3 m
Quasipeak (dBV/m) Peak (dBV/m) C-Average (dBV/m)

30 to 230 52 to 45 -- --
230 to 1000 52 -- --

1000 to 3000 -- 76 56
3000 to 6000 -- 80 60

Note.- ISM frequencies included in the operation mode of the EUT are excluded of the limits valuation, in this case 2,4 GHz.

3.- Test conditions:

- Equipment in continuous operation, normal mode (switch not activated) and emergency mode (cycles of
activation and remote deactivation of the switch).
- Measures in vertical and horizontal polarization and 4 sides (front, left, rear and right)

4.- Graphs:

The pages 4 to 7 of the Annex show the resulting graphs obtained during the tests.

5.- Frequencies study and evaluation:

Levels measured did not exceed the limits established by the Standard in the test conditions above
specified. The sweeps displayed in the Annex graphs show that all the PEAK, QUASIPEAK and
C-AVERAGE values are at levels below the indicated limits, therefore the sample is IN CONFORMITY with
the requirements indicated in the applied test specifications.

Note.- ISM frequencies included in the operation mode of the EUT are excluded of the limits valuation, in this case 2,4 GHz.
TEST REPORT Nº 2418/0482 Page 4 of 8

INMUNITY TO OVERVOLTAGE (SURGES) OF POWER SUPPLY

STANDARD APPLIED : UNE-EN 50121-3-2 (Specifications - Table 3)


UNE-EN 61000-4-5 (Test method)

TEST SPECIFICATIONS:

Performance criterion of the Standard. ............... : B


Test voltage LINE-GROUND (kV) ........................ : 2
Test voltage LINE-LINE (kV) ................................ : 1
Waveform (s) ........................................................ : 1,2 / 50
Source impedance ................................................. : 42  ; 0,5 µF
Port tested .............................................................. : Main supply: Between “+” and “-“ terminals & Between “+“
and GND & “-“ and GND terminals.
Polarity.................................................................... : Positive / Negative
Number of pulses by test ...................................... : 5
Frequency of pulses .............................................. : 1 pulse / minute
Supply voltage of EUT (V) ..................................... : 72 V d.c.
Operation mode ..................................................... : Equipment in continuous operation, normal mode (switch not
activated) and emergency mode (cycles of activation and remote deactivation of the switch).

Test site ................................................................. : Laboratory of Electrical Testing (EMC)


Test date ................................................................. : 2018/ 07/02
Temperature (ºC)/ RH (%) / At. pressure (hPa) .... : 25/30/940

MAIN TEST EQUIPMENT:

 Surge Generator EMC PARTNER TRA3000


 Limiter Resistor, (in series with generator), of 42 Ω ± 10 %. + 0,5 µF
 Isolating support (wood)
 Earth plane of reference, (aluminum layer 2 x 1 m).
 Other accessories

FINAL RESULTS:

During and after the test, the operation of the equipment under test (EUT) is according to the normal performance
expected; no degradation or function loss is appreciated. Performance criterion: B

The equipment does not become dangerous as a result of the application of the test.

According to the above exposed, the equipment under test is IN CONFORMITY, in the test conditions performed,
with the requirements defined by the Standard to this test.
TEST REPORT Nº 2418/0482 Page 5 of 8

INMUNITY TO ELECTROSTATIC DISCHARGES (ESD)

STANDARD APPLIED : UNE-EN 50121-3-2 (Specifications – Table 5)


UNE-EN 61000-4-2 (Test method)
TEST SPECIFICATIONS:
Performance criterion of the Standard. ............... : B
Test voltage (kV) ................................................... : 8 / 6 (Non conductive accessible parts/ Conductive)
Application Mode ................................................... : Air discharge / Contact discharge
Polarity.................................................................... : Positive / Negative
Supply voltage of EUT (V) ..................................... : 72 V d.c.
Operation mode ..................................................... : Equipment in continuous operation, normal mode (switch not
activated) and emergency mode (cycles of activation and remote deactivation of the switch).

Test site ................................................................. : Laboratory of Electrical Testing (EMC)


Test date ................................................................. : 201/07/05
Temperature (ºC)/ RH (%) / At. pressure (hPa) .... : 26 / 38 / 952

MAIN TEST EQUIPMENT:

 ESD generator HAEFELY ONYX30


 Isolating support (wood)
 Earth plane of reference, (aluminum layer 2 x 1 m)
 Other accessories

POINTS OF APPLICATION ON THE EQUIPMENT (only accessible parts – front):


(CONTACT DISCHARGES: BLUE; AIR DISCHARGES: RED)
Indirect coupling by contact on horizontal and vertical plane without incident.

FINAL RESULTS:
During and after the test, the operation of the equipment under test (EUT) is according to the normal performance
expected; no degradation or function loss is appreciated. Performance criterion: A
The equipment does not become dangerous as a result of the application of the test.
According to the above exposed, the equipment under test is IN CONFORMITY, in the test conditions performed,
with the requirements defined by the Standard to this test.
TEST REPORT Nº 2418/0482 Page 6 of 8

INMUNITY TO ELECTRICAL FAST TRANSIENT (EFT / BURST)

STANDARD APPLIED : UNE-EN 50121-3-2 (Specifications – Table 3)


UNE-EN 61000-4-4 (Test method)

TEST SPECIFICATIONS:

Performance criterion of the Standard. ............... : A


Test voltage (kV) ................................................... : 2
Impulse repetition frequency (kHz) ...................... : 5
Impulse rise time (ns) ............................................ : 5
Impulse duration (ns) ............................................ : 50
Burst duration (ms) ............................................... : 15
Burst period (ms) ................................................... : 300
Polarity of pulses ................................................... : Positive / Negative
Ports tested ............................................................ : Main supply (+,-, GND)
Coupling modes .................................................... : Direct injection
Supply voltage of EUT (V) ..................................... : 72 V d.c.
Operation mode ..................................................... : Equipment in continuous operation, normal mode (switch not
activated) and emergency mode (cycles of activation and remote deactivation of the switch).

Test site ................................................................. : Laboratory of Electrical Testing (EMC)


Test date ................................................................. : 2018/07/02
Temperature (ºC)/ RH (%) / At. pressure (hPa) .... : 25 / 30 / 940

MAIN TEST EQUIPMENT:

 Surge Generator EMC PARTNER TRA3000


 Isolating support (wood)
 Earth plane of reference, (aluminum layer 2 x 1 m).
 Other accessories

FINAL RESULTS:

During and after the test, the operation of the equipment under test (EUT) is according to the normal performance
expected; no degradation or function loss is appreciated. Performance criterion: A

The equipment does not become dangerous as a result of the application of the test.

According to the above exposed, the equipment under test is IN CONFORMITY, in the test conditions performed,
with the requirements defined by the Standard to this test.
TEST REPORT Nº 2418/0482 Page 7 of 8

INMUNITY TO CONDUCTED RFI (INDUCED BY RADIO FREQUENCY FIELDS)

STANDARD APPLIED: UNE-EN 50121-3-2 (Specifications – Table 3)


UNE-EN 61000-4-6 (Test method)

TEST SPECIFICATIONS:

Performance criterion of the Standard. ............... : A


Frequency sweep (MHz)........................................ : 0,15 to 80
Level (V rms) .......................................................... : 10 (Without modulation)
Ports tested ............................................................ : Main supply (+; -; GND)
Coupling modes .................................................... : CDN-801-M3-25
Modulation characteristics ................................... : 80% AM, 1 kHz, sinusoidal wave
Supply voltage of EUT (V) ..................................... : 72 V d.c.
Operation mode ..................................................... : Equipment in continuous operation, normal mode (switch not
activated) and emergency mode (cycles of activation and remote deactivation of the switch).

Test site ................................................................. : Laboratory of Electrical Testing (EMC)


Test date ................................................................. : 2018/07/03
Temperature (ºC)/ RH (%) / At. pressure (hPa) .... : 26 / 42 / 951

MAIN TEST EQUIPMENT:

 Signal Generator Rohde&Schwarz / SMB100A


 RF Amplifier Rohde&Schwarz / A125
 Coupling network: CDN-801-M3-25
 Isolating support (wood)
 Earth plane of reference, (aluminum layer 2x1 m)
 Other accessories

FINAL RESULTS:

During and after the test, the operation of the equipment under test (EUT) is according to the normal performance
expected; no degradation or function loss is appreciated. Performance criterion: A

The equipment does not becomes dangerous as a result of the application of the test.

According to the above exposed, the equipment under test is in CONFORMITY, in the test conditions performed,
with the requirements defined by the Standard to this test.
TEST REPORT Nº 2418/0482 Page 8 of 8

INMUNITY TO RADIATED FIELDS (RFI INTERFERENCES – AMPLITUDE MODULATED)

STANDARD APPLIED: UNE-EN 50121-3-2 (Specifications – Table 5)


UNE-EN 61000-4-3 (Test method)

TEST SPECIFICATIONS:

Performance criterion of the Standard. ............... : A


Frequency sweep (MHz)........................................ : 80-800 / 800-1000 / 1400-2100 / 2100-2500 / 5100-6000
Field level (V/m) ..................................................... : 20 / 20 / 10 / 5 / 3 without modulation
Modulation characteristic ..................................... : 80% AM (1kHz)
Polarization ............................................................ : Vertical / Horizontal (front positioning of EUT)
Supply voltage of EUT (V) ..................................... : 72 V d.c.
Operation mode ..................................................... : Equipment in continuous operation, normal mode (switch not
activated) and emergency mode (cycles of activation and remote deactivation of the switch).

Test site ................................................................. : Laboratory of Electrical Testing (Full Anechoic Room)


Test date ................................................................. : 2018 / 07 / 04
Temperature (ºC)/ RH (%) / At. pressure (hPa) .... : 25 / 41 / 947

MAIN TEST EQUIPMENT:

 Signal Generator Rohde&Schwarz / SMB100A


 RF Amplifier Rohde&Schwarz / BC125
 RF Amplifier Rohde&Schwarz / D30E30
 Isotropic field monitor PMM / EP601
 Antenna Schwarzbeck / VULB 9162

FINAL RESULTS:

During and after the test, the operation of the equipment under test (EUT) is according to the normal performance
expected; no degradation or function loss is appreciated. Performance criterion: A

The equipment not becomes dangerous as a result of the application of the test.

According to the above exposed, the equipment under test is IN CONFORMITY, in the test conditions performed,
with the requirements defined by the Standard to this test.
TEST REPORT Nº 2418/0482 ANNEX Page 1 of 8

ANNEX
TEST REPORT Nº 2418/0482 ANNEX Page 2 of 8

Conducted Emission 0,15-30 MHz


EUT: ALARM HANDLE AMETSIS / LM11944/450
Manuf.: AMETSIS, S.L.
Op. Cond.: EQUIPMENT IN OPERATIVE; Normal Mode
Operator: RBT 2418/0482
Test Spec.: UNE-EN 50121-3-2 limit QP (red Line)
Comment: ENVELOPE POSITIVE AND NEFATIVE TERMINALS, sweeps PEAK (blue) , Power Supply: 72 Vcc

F u ll S p e c tru m

100
5 0 1 2 1 -3 -2 D C
90

80

70
Level in dBµV

60

50

40

30

20

10
150k 3 0 0 4 0 05 0 0 8 0 01 M 2M 3M 4M 5M 6 8 10M 20M 30M
F re q u e n c y in H z

P re v ie w R e s u lt 1 -P K + Critic a l_ F re q s P K + 5 0 1 2 1 -3 -2 D C
F in a l_ R e s u lt Q P K F in a l_ R e s u lt C A V

sin rearme
TEST REPORT Nº 2418/0482 ANNEX Page 3 of 8

Conducted Emission 0,15-30 MHz


EUT: ALARM HANDLE AMETSIS / LM11944/450
Manuf.: AMETSIS, S.L.
Op. Cond.: EQUIPMENT IN OPERATIVE; EMERGENCY MODE (CYCLES OF REMOTE SWITCHING)
Operator: RBT 2418/0482
Test Spec.: UNE-EN 50121-3-2 limit QP (red Line)
Comment: ENVELOPE POSITIVE AND NEFATIVE TERMINALS, sweeps PEAK (blue) , Power Supply: 72 Vcc

F u ll S p e c tru m

100
5 0 1 2 1 -3 -2 D C
90

80

70
Level in dBµV

60

50

40

30

20

10
150k 3 0 0 4 0 05 0 0 8 0 01 M 2M 3M 4M 5M 6 8 10M 20M 30M
F re q u e n c y in H z

P re v ie w R e s u lt 1 -P K + Critic a l_ F re q s P K + 5 0 1 2 1 -3 -2 D C
F in a l_ R e s u lt Q P K F in a l_ R e s u lt C A V

rearmando
TEST REPORT Nº 2418/0482 ANNEX Page 4 of 8

Radiated Emission 30 - 1000 MHz


EUT: ALARM HANDLE AMETSIS / LM11944/450
Manuf.: AMETSIS, S.L.
Op. Cond.: EQUIPMENT IN OPERATIVE MODE: NORMAL MODE
Operator: RBT 2418/0482
Test Spec.: UNE-EN 50121-3-2 limit QP (red)
Comment: ENVELOPE (Vertical & Horizontal Polarizations; 4 sides), sweep PEAK (blue) Power Supply: 72 Vdc
TEST REPORT Nº 2418/0482 ANNEX Page 5 of 8

Radiated Emission 30 - 1000 MHz


EUT: ALARM HANDLE AMETSIS / LM11944/450
Manuf.: AMETSIS, S.L.
Op. Cond.: EQUIPMENT IN OPERATIVE MODE: EMERGENCY MODE (CYCLES OF REMOTE SWITCHING)
Operator: RBT 2418/0482
Test Spec.: UNE-EN 50121-3-2 limit QP (red)
Comment: ENVELOPE (Vertical & Horizontal Polarizations; 4 sides), sweep PEAK (blue) Power Supply: 72 Vdc

F u ll S p e c tru m

80

70

60

6 1 0 0 0 -6 -4 _ 8 0 -1 0 0 0 M H z_ F A R
50
Level in dBµV/m

40

30

20

10

0
30M 50 60 80 100M 200 300 400 500 800 1G
F re q u e n c y in H z
TEST REPORT Nº 2418/0482 ANNEX Page 6 of 8

Radiated Emission 1000 - 6000 MHz


EUT: ALARM HANDLE AMETSIS / LM11944/450
Manuf.: AMETSIS, S.L.
Op. Cond.: EQUIPMENT IN OPERATIVE MODE: NORMAL MODE
Operator: RBT 2418/0482
Test Spec.: UNE-EN 50121-3-2 limit PK (red) AV (purple)
Comment: ENVELOPE (Vertical & Horizontal Polarizations; 4 sides), sweep PEAK (blue), AVERAGE (green) Power Supply: 72 Vdc

F u ll S p e c tru m

110

100

90

6 1 0 0 0 -6 -4 _ 1 -6 G H z _ P K
80
Level in dBµV/m

70

6 1 0 0 0 -6 -4 _ 1 -6 G H z _ A V
60

50

40

30

20
1G 2G 3G 4G 5G 6G
F re q u e n c y in H z
TEST REPORT Nº 2418/0482 ANNEX Page 7 of 8

Radiated Emission 1000 - 6000 MHz


EUT: ALARM HANDLE AMETSIS / LM11944/450
Manuf.: AMETSIS, S.L.
Op. Cond.: EQUIPMENT IN OPERATIVE MODE: EMERGENCY MODE (REMOTE SWITCHING CYCLES)
Operator: RBT 2418/0482
Test Spec.: UNE-EN 50121-3-2 limit PK (red) AV (purple)
Comment: ENVELOPE (Vertical & Horizontal Polarizations; 4 sides), sweep PEAK (blue), AVERAGE (green) Power Supply: 72 Vdc

F u ll S p e c tru m

110

100

90

6 1 0 0 0 -6 -4 _ 1 -6 G H z _ P K
80
Level in dBµV/m

70

6 1 0 0 0 -6 -4 _ 1 -6 G H z _ A V
60

50

40

30

20
1G 2G 3G 4G 5G 6G
F re q u e n c y in H z
TEST REPORT Nº 2418/0482 ANNEX Page 8 of 8

Photo of Radiated Emission and Immunity tests

Equipment Under Test detail