BNWAS Flyer ROCKSON-GuardianV11
BNWAS Flyer ROCKSON-GuardianV11
BNWAS Flyer ROCKSON-GuardianV11
~ all major classification societies, fully in compliance with lEG 626 16 standard
__ -~ EH[•',' FOP __ _
operating F I:II,:E>: Ot~ / AUTO
device
144x72mm
connecting
module
reset units
bridge area WAR 220.1 .0.0
device
automatic start
from auto pilot
(dry contact)
- ships of 150 gross tonnage and upwards and passenger ships irrespective of size
constructed on or after 1 July 2011;
-passenger ships irrespective of size constructed 1 July 2011 , not later than first
survey after 1 July 2011 ;
-ships of 3,000 gross tonnage and upwards constructed before 1 July 2011,
not later than the first survey after 1 July 2012;
- ships of 500 gross tonnage and upwards but less than 3, 000 gross tonnage
constructed before 1 July 2011 , not later than the first survey after 1 July 2013
- ships of 150 gross tonnage and upwards but less than 500 gross tonnage
constructed before 1 July 2011 , not later than the first survey after 1 July 2014
sample system for huge sized vessel
reset unit
bridge wings WAR 220.2.1.0
bridge area
operating
device
automatic start
from auto pilot ...,. connecting
(dry contact & NMEA) module NMEA.
emergency call software
expans1on -
module
& alarm transfer inputs ..... inside console selector
(dry contacts & NMEA)
t
failure
t
to VDR (NMEA)
officer's
alarm stage #3 alarm stage #2
area panel for corridor cabin panels
up to 112dB{A) •
-- (back-up OOWs)
- when key switch has been turned to position , SELECT' a selection menue opens
and Master decides which back-up OOW cabin receives stage #2 alarm.
Multiple choice is possible!
bridge area
opera
device
automatic start
from auto pilot ~ connecting
(dry contact & NMEA) module NMEA.
emergency call software
expansiOn -
module
& alarm transfer inputs ~ inside console selector
(dry contacts & NMEA) f
failure
t
to VDR (NMEA)
I'
officer's
alarm stage #3 alarm stage #2
area panel for corridor cabin panels
up to 112dB(A) (back-up OOWs)
•
NMEA interface
-according to NMEA protocol lEG 61162-1 system sends all relevant operating
states to NMEA receiver, especially VDR system.
- clever logic allows to generate from each reset unit manually an emergency
back-up OOW call
- that useful periphery equipment makes OOW's job so much easier and is
increasing safety level on board
- complete sensor kit includes sensor with patch cable & distribution box
and electronic modul to be used as an extension to existing connecting module
1 75 ... 85dB(A)
ALARM ALARM
STAGE2
OFFICER'SAREA
OFFICER's
AREA
$ =8
0
1--H-++-1--15 5~1+I+1:;:::1:;:::1;:::: 1~
1 ;::::I ~~~::::;1::::;141::;:1:;::1:;:::1:;:::1f=1;::::1;::::
1~ ~ ~~1::::;1::::;1:::;:1::;:1+1:;:::1:;:::1:;:::1;::::1t-.1IHIHI-+1--l-[-+1-+1+I+I+I+-1+-1+-111--ill--tl-+1-+1-+1+I+I+I+-1+-1l--1+-1IHI-tl--l-1-+1-+1-+1- -.. t [s]
5 10 15 20 25 30 35 40 45 50 55 60
ALARM 1
STAGE 1
BRIDGE AREA
PRE·
ALARM =8
O 1--H-++-f--15 5~1+I +1:;:::1:;:::1;:::: 1~
, ;::::~ 1~1::::;1::::;,41:;::1:;::,:;:::,:;:::,+-1+-1t-
1 HI11--il-+1-+1-+1-+1+I-t-1+-1+-1+-1l--1IHIHI-+1--l-l-+1-+1+I+I+I+-1+-1+-111--ili--tl-tl-+1-+1+I-t-1-t-1+-1+-1l--1t-1IHIHI--l-l-+1-+1-+1- -• t(SJ
5 10 15 20 25 30 35 40 45 50 55 60
--
VISUAL 1
INDICATION RESET
BRIDGE AREA UNITS
0
1--H-++-1-t'> 51 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 .. t[s]
180 5 10 15 20 25 30 35 40 45 50 55 60
(3... 12 min)
'
PIR motion sensor reset push button reset unit in wall box reset unit w. buzzer
with electronic module pre- alarm indication pre- alarm indication pre- alarm & alarm stage #1
(12m, 90 °) bridge area bridge area open bridge wing area
WMS 220. 2.0.0 WAR 220.1.0.0 WAR 220.2.0.0 WAR 220.2.1.0
WATCH ALARM