HPM10000 48V Test Results
HPM10000 48V Test Results
HPM10000 48V Test Results
Dumu 3C, LT-11119, Vilnius www.miromax.lt | miromax@miromax.lt Phone: +370 648 16 391
Company:
Item Voltage Current P. input P. factor Frequency Torque Rotate P. output Efficiency
s V A W PF Hz mN.m rpm W %
1 47.87 14.545 696.29 1.000 0.0 420.0 4733 208.15 29.9
2 47.87 14.868 711.73 1.000 0.0 347.5 4731 172.15 24.2
3 47.86 16.493 789.31 1.000 0.0 200.0 4720 98.85 12.5
4 47.83 20.859 997.62 1.000 0.0 595.0 4690 292.20 29.3
5 47.78 28.729 1372.61 1.000 0.0 1640.0 4636 796.13 58.0
6 47.70 39.659 1891.85 1.000 0.0 2925.0 4563 1397.57 73.9
7 47.61 53.020 2524.16 1.000 0.0 4382.5 4475 2053.58 81.4
8 47.51 68.424 3250.81 1.000 0.0 6042.5 4382 2772.59 85.3
9 47.41 85.541 4055.28 1.000 0.0 7857.5 4282 3523.12 86.9
10 47.30 103.661 4902.92 1.000 0.0 9797.5 4183 4291.41 87.5
11 47.26 123.218 5822.95 1.000 0.0 11830.0 4091 5067.70 87.0
12 47.33 142.868 6762.28 1.000 0.0 13985.0 4013 5876.63 86.9
13 47.30 162.723 7697.18 1.000 0.0 16152.5 3931 6648.74 86.4
14 47.28 182.568 8631.79 1.000 0.0 18295.0 3855 7385.05 85.6
15 47.23 201.640 9522.95 1.000 0.0 20382.5 3785 8078.30 84.8
16 47.03 219.285 10312.43 1.000 0.0 22300.0 3707 8656.14 83.9
17 46.77 235.073 10994.34 1.000 0.0 24005.0 3634 9134.47 83.1
18 46.61 247.863 11552.25 1.000 0.0 25317.5 3581 9493.40 82.2
19 46.53 257.188 11966.29 1.000 0.0 26252.5 3547 9750.54 81.5
20 46.48 263.805 12260.34 1.000 0.0 26925.0 3525 9938.29 81.1
21 46.43 268.957 12489.04 1.000 0.0 27422.5 3507 10070.23 80.6
22 46.40 273.243 12678.45 1.000 0.0 27860.0 3492 10187.13 80.3
23 46.37 277.053 12846.23 1.000 0.0 28227.5 3478 10280.13 80.0
24 46.34 280.695 13007.41 1.000 0.0 28595.0 3466 10378.04 79.8
25 46.31 283.920 13149.75 1.000 0.0 28910.0 3455 10459.06 79.5
26 46.29 286.955 13282.43 1.000 0.0 29230.0 3442 10535.04 79.3
27 46.30 288.954 13334,40 1.000 0.0 30628.0 3380 10834.68 81.2
6
www.miromax.lt
MIROMAX Ltd Phone: +370 700 30 154
Dumu 3C, LT-11119, Vilnius www.miromax.lt | miromax@miromax.lt Phone: +370 648 16 391
Base speed area. At this point (0-3380 "Peak Power" point. 10834 W At this point motor could operate
RPM) "Constant Torque" 30,63 Nm continously for long period of time.
starts to drop due to incresing back You will find this specific Power and
EMF. Operating at peak torque
Torque value at the motor spec sheet as
continuously may increase temperature
of the motor significantly. "Nominal/Rated Torque" 27 Nm and
"Nominal/Rated Power" 10 kW at the
"Rated Speed" 3500 RPM.
HPM 10000 (48V)
12000,00 35
10000,00 30
25
8000,00
Torque, Nm
Power, W
20
6000,00
15
4000,00
10
2000,00 5
0,00 0
0,00 1000,00 2000,00 3000,00 4000,00 5000,00
Rotational speed, RPM
Zero Torque point, where motor will
operate at the maximum speed 4733
P. output W Torque N.m RPM (When no load applied).
For example, if motor is with windings 48V, this motor can also be run at lower (or Higher) voltages, such as
36V (or 72V). The difference is that you wouldn't get as much power output since a lower voltage is associated
a lower max attainable rpm. As power (W or Nm/s) is the product of angular speed (1/seconds) and torque (nm),
with the same amount of torque and a lower rpm, you would have a lower power output.
You can achieve the same amount of torque at any voltage as torque is directly dependent on current. You
may see something called a torque constant, such as Nm/A or ft-lbs/A. Simply multiply by the current, and
you'll get the torque output before accounting for mechanical and electrical losses.
The main limiting factor on the amount of current you can pump into a motor is heat, which can melt
the insulating varnish if too high.
At respectively currents the motor torque at any supply voltage (36V or 48V or 72V) will be the same.
Therefore, if motor (& controller) cooling is very good duration time of max Power / Torque can last for longer.
www.miromax.lt