SERIES 599-Y2000

Copper Conductive Coating

Features Product Description

SERIES 599-Y2000 A sprayable


metallic coating system using a SYSTEM: One component, air dry.
specially formulated non-oxidizing
copper as the conductive agent. SOLIDS: 29% ± 2% by weight.
Developed for use as an RFI and
EMI shield for plastic electronic DENSITY: 8.5 ± .2 lbs. per gallon (1.02 ± 0.03 kg per liter)
equipment housings. 599-Y2000
can be used on acrylic, ABS and VISCOSITY @75°F ± 3°F (24°C ± 2°C): 19 ±2 Sec. (#2 EZ
structural foams, e.g. Valox, etc. as Viscosity Cup - Mfr. Paul N. Gardner)
well as solvent sensitive substrates
such as polycarbonate and ADHESION: Excellent to most plastic substrates.
polystyrene. For Noryl use 599-
Y2000T (Y1371). ATTENUATION: More than 75 dB from 1 MHz to 1 Ghz.

THINNER: Check viscosity after thorough mixing. Adjust to 19


seconds (#2 EZ Viscosity Cup) with MEK, if
necessary.

APPLICATION HVLP or standard air gun with fluid recirculation


METHOD: system is recommended. A pressure pot may be
used provided that: (1) it has a large diameter,
paddle-type agitator to keep copper in suspension
and (2) a short translucent MEK-resistant fluid line
of 1/8" (3.15 mm) ID or smaller is used (such as
Binks Synflex) to prevent settling in the line.
NOTE: The solvent system of this
product is designed for fast drying DRYING TIME: 30 minutes flash off at room temperature; then 30
and early measuring of conductivity. minutes @ 160°F. (71°C.) at 2.0 mils (50 microns).
In hot, humid weather the fast drying Longer if thicker film, shorter if thinner film, to
may result in sporadic blushing. achieve desired resistivity.
Blushing is a whitening of the
surface of the coating caused by HUMIDITY No change in resistivity or attenuation when tested
condensation of water in a hot, RESISTANCE: in accordance with MIL-STD-202 Method 106 - 40
humid environment. The addition of cycles; MIL-STD-810 Method 507 Procedure 5 -
2-3% (3-4 ounces per gallon) of 480 hours cycling; Meets UL Specification 746-C
Butyl Cellosolve(Ethylene-Glycol-
Mono-Butyl-Ether) will eliminate
blushing.

PPG Industries, Inc.


Springdale Plant The technical data presented in this bulletin is based upon information believed by PPG to be currently accurate.
125 Colfax St. However, no guarantees of accuracy, comprehensiveness, or performance are given or implied. Continuous
Springdale, PA 15144 improvements in coatings technology may cause future technical data to vary from what is in this bulletin. Contact your
ppgindustrialcoatings.com PPG representative for the most up-to-date information.

1. ©2014 PPG Industrial Coatings 02/19/2014

/2014
SERIES 599-Y2000
Copper Conductive Coating

SURFACE <0.05 ohms/sq. @ 1 mil (25 microns) DFT.


RESISTIVITY: <0.025 ± 0.005 ohms/sq. @ 2 mils (50 microns) . These readings can be achieved under proper
conditions: (1) properly mixed paint; (2) film is 100% dry.

THEORETICAL 190.4 ft2. per gallon/ 1 mil (4.7m2/liter per 25 microns)


COVERAGE: @ 100% transfer efficiency (computed on volume solids)

STORAGE LIFE: Recommended storage in unopened containers is 12 months from date of


shipment. Older material should have all Q.C. requirements rechecked before using.

2 ©2014 PPG Industrial Coatings 02/19/2014