Preliminary Data Sheet

VI-410
HUMAN VIBRATION MONITOR

New Model The Quest VI-410 is a four


channel human vibration
analyzer that can also be
used as an integrating real-time sound
analyzer.

The VI-410 utilizes the latest in digital


signal processing technology to facilitate
measurements in accordance with Inter-
national and U.S.A. standards and regu-
latory requirements, including the Euro-
pean Vibration Directive in effect for the
25 states of the EC.

Four independent channels permit use


of tri-axial accelerometers for measuring
both hand-arm and whole body vibration
and also simultaneously utilizing either
an acoustic microphone or a mono-axial
accelerometer on the 4th channel. Al-
ternatively, each of the 4 channels may
be independently configured with sepa-
rate accelerometers.

The Multi-Purpose VI-410 Human Vibration Monitor of-


fers:
 1/1 or 1/3 Octave Real-Time Analysis
 Optional FFT Spectra Recording
 Vibration RMS, Peak, VDV, MTVV or Max, Peak to Peak
 Built-in frequency weightings per ISO 2631 and 5349
 Precision Class 1 Sound Level Meter

www.questtechnologies.com
SPECIFICATIONS FOR THE VI-410
Number of channels (Inputs): (4) input channels, 20 kHz real time, simultaneous vibration and
noise measurements

Data Logging: Time history logging to internal memory


Analyzer: 1/1 and 1/3 Octave-Band analysis
Optional FFT Spectra
Optional RPM rotation speed measurements parallel to vibration
measurements (1-99999 rpm)
Standards: Human vibration measurements meeting ISO 8041 and Acoustic
Class 1 requirements of ISO 61672-1, plus latest EU directives
for vibration and noise; also meets older IEC 60804 and 60651
sound level meter standards
EMI/RFI Standards: CE Compliant

Vibration Measurements: RMS, VDV, Peak, Peak-Peak, Min, Max (MTVV), Vector Sum, A(8),
EAV Time, ELV Time, Time History, Aeq

Sound Level Measurements: SPL, Leq/Lavg, SEL, Ldn, Ltm3, Ltm5, L1 to L99, Lmax, Lmin,
Lpeak, Time History
Vibration Filters: WD, WK, WC, WJ, WM, WB, WG (ISO 2631), Wh (ISO 5349), HP1,
HP3, HP10, Vel1, Vel3, Vel10, VelMF, Dil1, Dil3, Dil10, KB

Sensors: Tri-axial accelerometer in both Hand-Arm and Whole Body


types; mono-axial accelerometers; Class 1 Precision micro-
phones and preamplifier

Data Output Sockets: USB output to QuestSuite Professional II software

Whole-Body Sensor: Tri-axial seat pad accelerometer, 100mV/g sensitivity

Hand-Arm Sensor: Miniature tri-axial accelerometer, 10mV/g sensitivity

Vibration Range: 0.003 ms-2 to 500 ms2 (Accelerometer Dependent)


Frequency Range: 0.5 Hz to 20 kHz (input accelerometer dependent)
Display: LCD 128 X 64 pixels plus icons with backlighting

Memory: 32 MB non-volatile flash type

Power Supply: Four AA batteries (alkaline) or Four AA rechargeable (NiMH) (not


included)
Environmental Conditions: Temperature from –10º to +50ºC
Humidity up to 90%RH non-condensing

Dimensions and Weight: 140 X 82 X 42 mm and 510 grams with batteries installed

www.questtechnologies.com
1060 Corporate Center Drive
Oconomowoc, Wisconsin USA 53066
Telephone: +1-262-567-9157