Curvature Ductility,: Uniaxial
Curvature Ductility,: Uniaxial
Curvature Ductility,: Uniaxial
Wall Design: Uniaxial
Strength Reduction Factor: = 0.75
Selected Curvature Ductility: = 9.00
0.29
Uniaxial
=
k, [MPa]
22.4 1st Mode 2nd Mode Kinem. Envelope
Floor hi [m] hiACUM [m] Vi,1 [kN] Vi,2 [kN] Vi,K [kN] Vi [kN]
9.0, 0.0875
7 3.2 22.4 194 ‐157 108 340 Biaxial
0.10
6 3.2 19.2 574 ‐290 233 858
5 3.2 16 863 ‐213 384 1265
0.05
4 3.2 12.8 1066 20 572 1638
3 3.2 9.6 1190 340 823 2042
2 3.2 6.4 1250 661 1200 2538 1 3 5 7 13 15
1 3.2 3.2 1267 880 1953 3338
0 0 0 1267 880 1953 3338
Curvature Ductility,
Taking into account for Axial Load Contribution: NO
n Bar s [m]
Selected Stirrups: 6 #4 0.15
2
Reinforcement per Unit Length: AV /s = 5.160 [mm /mm]
Length to Stirrups Centerline: Dc = 6887 [mm]
Curvature Factor: k = 0.0875
Neutral Axis to Wall Length Ratio: c/Lw = 0.122337
Neutral Axis: c = 856 [mm]
Compressive Strut Angle: Tan (c) = 0.960
The selected transverse reinforcement at the base is appropiate