Zenith ZBTS/ ZBTSD/ZBTSCT: Transfer/Bypass-Isolation Transfer Switches
Zenith ZBTS/ ZBTSD/ZBTSCT: Transfer/Bypass-Isolation Transfer Switches
Zenith ZBTS/ ZBTSD/ZBTSCT: Transfer/Bypass-Isolation Transfer Switches
from GE
Zenith ZBTS/
ZBTSD/ZBTSCT
Transfer/Bypass-Isolation
Transfer Switches
The Automatic Transfer Switch is installed on a draw-out mechanism, with electrical and mechanical interlocks for secure
removal after load bypass. The ATS control/logic panel is mounted on the enclosure door and connected by a wire harness and
multi-pin disconnect plugs. The transfer switch and/or the control panel may be tested, isolated and removed for maintenance
without load interruption.
The bypass-isolation switch module is the same basic design as the automatic transfer switch module and thus has the same
electrical ratings. Manually operated, it features high speed, quick make/quick break contact action. The bypass-isolation switch
has three basic positions:
1. Automatic: Source 1 (Normal) bypass contacts open, Source 2 (emergency) bypass contacts open.
2. Bypass Normal: Source 1 (Normal) bypass contacts closed, Source 2 (emergency) bypass contacts open.
3. Bypass Emergency: Source 1 (Normal) bypass contacts open, Source 2 (emergency) bypass contacts closed.
Specifications
100, 150, 2, 3 83 (211) 30 (76) 28.5 (72.4) A 310 (141) 770 (350) 1–9
225, 260 4 83 (211) 30 (76) 28.5 (72.4) 380 (173) 840 (322)
400
600 3 90 (229) 36 (91) 28.25 (72) B 660 (299) 1220 (533)
4 90 (229) 40 (102) 28.25 (72) 770 (349) 1365 (619)
800, 1000 3 90 (229) 40 (102) 28.25 (72) 765 (347) 1355 (615)
1200 4 90 (229) 46 (117) 28.25 (72) 910 (413) 1570 (712)
1600, 2000 3 80 (202) 40.6 (103) 64.6 (164) C 1978 (897) 4044 (1835) 1 – 7, 10
2600 4 80 (202) 46.1 (117) 64.6 (164) 2275 (1032) 4431 (2010)
3000 3 80 (202) 40.6 (103) 64.6 (164) 2572 (1166) 4456 (2021) 1 – 7,
4 80 (202) 46.1 (117) 64.6 (164) 3049 (1383) 4977 (2258) 10 - 12
4000 3 90 (229) 47.5 (121) 81 (206) D 4310 (1955) 4660 (2113) 1 – 7,
4 90 (229) 54 (137) 81 (206) 5510 (2499) 5860 (2658) 10 – 11
ZBTSCT
AMPERE RATING POLES NEMA 1 ENCLOSED WEIGHT APPLICATION
NOTES
HEIGHT (A) WIDTH (B) DEPTH (C) REFERENCE FIGURE OPEN TYPE NEMA 1
100, 150, 3 90 (229) 36 (91) 28.25 (72) B 730 (331) 1280 (581) 1–8
225, 260 4 90 (229) 40 (102) 28.25 (72) 840 (381) 1385 (628)
400, 600
800, 1000 3 90 (229) 40 (102) 28.25 (72) 835 (379) 1435 (651) 1-9
1200 4 90 (229) 46 (117) 28.25 (72) 980 (444) 1640 (744)
1600, 2000 3 80 (202) 40.6 (103) 64.6 (164) C 1978 (897) 4044 (1835) 1 – 7, 10
2600 4 80 (202) 46.1 (117) 64.6 (164) 2275 (1032) 4431 (2010)
3000 3 80 (202) 40.6 (103) 64.6 (164) 2572 (1166) 4456 (2021) 1 – 7,
4 80 (202) 46.1 (117) 64.6 (164) 3049 (1383) 4977 (2258) 10 - 12
4000 3 90 (229) 47.5 (121) 81 (206) D 4380 (1986) 4730 (2145)
4 90 (229) 54 (137) 81 (206) 5580 (2531) 5930 (2689)
Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25” door projection beyond base depth. Allow a minimum of 3” additional depth for projection of handle, light,
switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE factory for details.
5. Bypass Model product can not be ordered with inverted style.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4” in height for removable lifting lugs.
9. ZBTS(D) 600-1200A & ZBTSCT 100-1200A standard configuration is top entry. 14” rear adapter bay required for bottom entry.
Consult the GE factory for details.
10. Bypass switch weights for 1600 - 4000 amp units vary up to 10% based on connections variations. Weights shown are for
estimation only.
11. 3000 amp depth dimension shown is standard. Depending on your cable/conduit requirements you may desire a deeper
enclosure. Consult the GE factory for further details.
12. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE factory for details.
Reference Figure
OUTLINE DRAWINGS
Drawing or Diagram
* Line and load terminals are located in rear and arranged for bus bar connection.
* Terminal lugs are available at additional cost. Contact the GE factory for more details.
GE
Critical Power
601 Shiloh Road *Registered trademark of the General Electric Company.
The GE brand, logo, and lumination are trademarks of the General Electric Company. © 2016 General Electric Company.
Plano, TX 75074 Information provided is subject to change without notice. All values are design or typical values when measured under
+1 877 546 3243 laboratory conditions.
www.gecriticalpower.com PB-5068, Rev. 05/2016