CHASSIS MODULE OUTPUT PINS

(MAXIMUM ALLOWABLE CURRENT LOAD)

Full Feature CHM (part #06-34530-XXX)


20A C3.A - OPT. (Fuel Water Separator Heater)

C4.C - Left Park Lamp


C4.L - Right Park Lamp
20A C4.D - Left Marker Lamp
Combined
C4.M - Right Marker Lamp
C2.F - Trailer Marker Relay

C3.N - Turn Left Front/Side


7.5A*
C1.G - Turn Left Rear
Combined
C2.H - Trailer Turn Left
C3.R - Turn Right Front/Side
7.5A*
C1.P - Turn Right Rear
Combined
C2.E - Trailer Turn Right
C1.A - Left Backup Lamp
6.7A

Chassis Module
C1.J - Right Backup Lamp
Combined
C1.H - Backup Alarm

6.7A C3.L - Right Low Beam

6.7A C4.K - Right High Beam

NOTE: 6.7A C1.N - Left Stop Lamp


Currents listed are the maximum
allowable combined current load
6.7A C1.L - Right Stop Lamp
for each output pin or group of
pins. When maximum allowable
current load is exceeded, the 6.7A C3.K - Right DRL
CHM software will shut the
output pin or group of pins. 6.7A C4.F - Left DRL

In Test Mode, the outputs will 6.7A C3.C - OPT. (Fog/Road Lamps)
deliver more current load than Combined C3.D - OPT. (Fog/Road Lamps)
the maximum allowable current
values shown. When testing, do
not exceed the maximum
combined values for more than a
0.85A C5.H - AMU Solenoid #0
few minutes or the life of the
output driver inside the CHM 0.85A C5.J - AMU Solenoid #1
may be shortened.
0.85A C5.L - AMU Solenoid #2
*Maximum allowable combined
current load when turn signals 0.85A C5.M - AMU Solenoid #3
are flashing.
0.2A C2.A - Trailer Power Relay
CHASSIS MODULE OUTPUT PINS
(MAXIMUM ALLOWABLE CURRENT LOAD)

Standard Feature CHM (part #06-42391-000)

C4.C - Left Park Lamp

20A C4.L - Right Park Lamp


Combined C4.D - Left Marker Lamp
C4.M - Right Marker Lamp

7.5A* C3.N - Turn Left Front/Side

Chassis Module
Combined C1.G - Turn Left Rear

7.5A* C3.R - Turn Right Front/Side


Combined C1.P - Turn Right Rear

C1.A - Left Backup Lamp


6.7A C1.J - Right Backup Lamp
Combined
C1.H - Backup Alarm
NOTE:
Currents listed are the maximum 6.7A C3.L - Right Low Beam
allowable combined current load
for each output pin or group of 6.7A C4.K - Right High Beam
pins. When maximum allowable
current load is exceeded, the 6.7A C1.N - Left Stop Lamp
CHM software will shut the
output pin or group of pins. 6.7A C1.L - Right Stop Lamp

In Test Mode, the outputs will


deliver more current load than
the maximum allowable current
values shown. When testing, do
not exceed the maximum
combined values for more than a
few minutes or the life of the
output driver inside the CHM
may be shortened.

*Maximum allowable combined


current load when turn signals
are flashing.
EXPANSION MODULE OUTPUT PINS
(MAXIMUM ALLOWABLE CURRENT LOAD)

Expansion Module (part #06-42399-000)

Expansion Module
6.7A C3.R - Spare Output #0

NOTE:
Currents listed are the maximum 6.7A C3.L - Spare Output #1
allowable current load for each
output pin. When maximum
allowable current load is
exceeded, the EXM software will 6.7A C1.N - Spare Output #2
shut the output pin.
6.7A C1.L - Spare Output #3
In Test Mode, the outputs will
deliver more current load than
the maximum allowable current
values shown. When testing, do
not exceed the maximum values
for more than a few minutes or
the life of the output driver inside
the EXM may be shortened.