Nothing Special   »   [go: up one dir, main page]

Air Receiver Sizing Calculation

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

IA Receiver HOLD UP TIME 30 MINS.

Peak IA requirement /hr


= 30 Nm3/h C  28.96
V 
Hold up time = 30
0.50
min
hr
λ 1  λ 2   22.414

Volume = 15.00 Nm3 28.96  P1  1.0197   273.15 


λ1    1  
Mol. Wt = 28.96 22.414  1.033

  273.15   
Mass = 19.38 kg

Initial Pressure = 6.0 barg 28 .96  P 2  1.0197   273.15 


λ2    1  
22 .414  1 .033   273.15   
Final Pressure = 4.0 barg
Temperature = 45 0
C
R (Gas Constant) = 0.083
z (compressibility Factor) = 0.997

IA density @ 6 barg = λ1 5.48 Kg/m3


IA density @ 4 barg = λ2 3.29 Kg/m3
Density diff 2.20 Kg/m3

Gas hold-up vol = 8.83 m3

Air receiver Volume. 8.83


Vessel L/D Ratio 1.30
Diameter (m) 2.00
Height (m) 2.60
Air receiver Volume m3 8.17
Dish Volume (Ellipsoidal
2.09
head). m3
Total Volume. m3 10.26