Design of Base Plate & Anchor Bolt (Crusher House)
Design of Base Plate & Anchor Bolt (Crusher House)
Design of Base Plate & Anchor Bolt (Crusher House)
HE-300A
ZONE I 6 Nos 1-1/4 " dia bolt
18.1
RDSI
TANJUNG JATI B RE-EXPANSION PROJECT-TJB-5 & 6
DESIGN CALCULATION FOR CRUSHER HOUSE
RDSI
TANJUNG JATI B RE-EXPANSION PROJECT-TJB-5 & 6
DESIGN CALCULATION FOR CRUSHER HOUSE
Two edge supported Plate (Refer Moody's Chart For Moments & Reactions for Rectangular Plate)
b= 11.8 in
a= 5.89 in
a/b= 0.50
Moment co-efficient= 0.1074
Max. Moment= co-eff x p x b2= 2.198 kip-in/in
q= 0.147 ksi
a1= 6 in. Refer "Design
d1= 12 in. Of Metal
Structure By K.
a1/d1= 0.52 Mukhanov"
α3 = 0.06
Max. Moment for Zone-II, M2 = α3 q d12= 1.230 kip-in./in
Considering 1 in. width of Base Plate, Zp = (1 X tp ) /6 2
in3
Allowable bending stress in Base plate , Fb= 0.75 Fy = 0.75 x36 = 27 ksi
Governing moment for Zone -I & II is
= 2.198 kip-in/in
Thickness of plate required, tp= √(6M/27)
= 0.70 in
Adopt 1 in. thk Base Plate.
RDSI
TANJUNG JATI B RE-EXPANSION PROJECT-TJB-5 & 6
DESIGN CALCULATION FOR CRUSHER HOUSE
RDSI
TANJUNG JATI B RE-EXPANSION PROJECT-TJB-5 & 6
DESIGN CALCULATION FOR CRUSHER HOUSE
Check for Base Plate Thickness Against Bending Due to Bolt Tension:
For Zone-II
11.81 we considerd 60 deg dispersion of load on three side.
60 deg So, tension on each side = 0.033 kips
(Typical) 1 3.34
b1= 3.86 inch
2 b2= 6.82 inch
2.75
5.91 5.91 moment due to tension (1)= 0.11 kips-in
moment due to tension (2)= 0.19 kips-in
For Zone-I
RDSI