04 - Muse Ed - SR-02-0-PCB - 090327
04 - Muse Ed - SR-02-0-PCB - 090327
04 - Muse Ed - SR-02-0-PCB - 090327
PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
PCB
Revision History
Rev. Prepared Checked Approved
Date Revision Contents
No. by by by
Mar. Harold
0 Release YS Kim DH Kim
2009 Lee
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
Index
6. DPC-140 PCB_________________________________________________________ 18
6.1. Configuration and Diagram _______________________________________________ 18
8. DCL-243 PCB_________________________________________________________ 26
8.1. Function _______________________________________________________________ 26
10.4. Hall connection of Simplex (In case 2 floors are controlled by 1of DHG-162) _______ 38
10.5. Hall connection of Duplex (In case 2 floors are controlled by 1of DHG-162)________ 39
10.6. Hall connection of through E/L (In case 1 floor is controlled by 1of DHG-162)______ 40
1. PCB application
1.1. PCB classification
a. Classification by name
A B C D E F
PCB Segment
1 : 60 ~ 105m/min
When the PCBs of the
same function has
When the PCB is used various forms and are not
commonly regardless of l ifi d i A B C d
speed, use the type name
developed and applied first.
H : Hall I : Indicator
D : Door F : Flickering
Distributed control M : Dot Matrices
S : Monitoring panel
E : E&I Panel
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
2. DOC-141 PCB
2.1. Layout of DOC-141 PCB
※ Caution
Green LED will flicker and red remains OFF in normal conditions.
And, TD1, 2, 3 LED blinking cycle is shorter than other green LED
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
b. Function table of switches, jumpers and dip switch (located in DOC PCB)
No. Name Switches Function Usually
1 SW2 Slide switch WE : EEPROM writing + 5V position
2 RESET Tact Run CPU Reset
3 SPEC2 DIP SW(8P) Spec. setting 2
4 SPEC1 DIP SW(4P) Spec. setting 1
5 TMR1 HEX SW Light timer of car
Detects door zone in
6 NOR/ABNOR Jumper 6P Normal
emergency
DIR Selects rotary encoder
7 Jumper Pin
direction
8 SH Jumper Pin Terminal R setting 1 G/A
9 SM Jumper Pin Terminal R setting 2 G/A
10 SL Jumper Pin Terminal R setting 3 G/A
11 JP1 Jumper Pin Terminal R setting 4 G/A
12 SW3 Slide switch ANN(DOA-100) Power switch
13 MAINT Jumper Pin Not used in DOC-141
SW2: WE position → EEPROM writing enable: when Spec. is changed into DOA PCB at
the side
+5V position → EEPROM writing unable: normal
Slide Switch
WE +5V
※ After Spec. Modification, JP1 should be positioned on +5 to prevent the spec. data from
deletion.
a) Reset: Reset Run CPU, Speed CPU and LON CPU
7 Unused Unused
※ If the jumper pin is set to ‘abnormal’ during manual rescue operation, the buzzer will
beep in case the lift is out of open zone. And when the lift has reach to open zone, the
buzzer beeping will stop to inform rescue person.
Note : 1. For the rescue operation, the main circuit breaker should be off.
2. Check the buzzer function under installation and ordinary maintenance.
3. After buzzer test, return the jumper pin to ‘Normal’.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
SH SH
Set of Terminal
Resistor
#32
DHG-162
#2
DHG-162
#1
DHG-162
Set of Terminal
Resistor
b. Duplex
a) Terminal Resistor of Duplex
DOC-131 DOC-131
SL SL
SH SH
Communication line
for Duplex
Remove jumper Set of Terminal
pin Resistor
#32 #32
DHG-162 DHG-162
#2 #2
DHG-162 DHG-162
b) Repeater PCB
A repeater PCB is applied to No.1 control panel in case the 2 Hall line and above 16
floors
No.1 No.2
DOC-131 DOC-131
01 01
SL SL
02 02
TML3
05
06
GND
P24
Normal : ON
Abnormal : OFF
#17 #17
DHG-162 DHG-162
#1 #1
DHG-162 DHG-162
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
DOC-141 PCB
U51 Operates LON CPU LON CPU O/S and LON program communication is invalid
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
3. DOX-100 PCB
3.1. DOX PCB function
a. As an I/O expansion PCB of DOC PCB, it is consist of input port and output port.
b. The hidden LED of DOC PCB is located on the DOX PCB to check elevator condition.
c. DOX PCB is mounted in the DOC PCB
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
4. DOA-100 PCB
4.1. Description of DOA -100 PCB
a. DOA -100 PCB is composed of LCD and Key pad and connected by DOC PCB and
16P twist flat cable.
b. LCD displays the currents condition about E&I panel and can be inputted various
commands, address, data, etc. through keypad.
c. As DOA-100 PCB has a timer, the back light turns OFF automatically without any keypad
input for about 7 minutes. Press any one of "E", "A", "6" and "2" key on the keypad to
turn ON the back-light again.
5. DOJ-130 PCB
5.1. General
a. As a power source PCB, it supplies power DC24V (Car LON PCB, Hall Button, External I/O
signal), DCC110V (C1ST, C1BR contactor) to E&I PANEL and AC110V (safety Chain)
b. It has fuse and LED that indicates power condition.
5.2. Outlook of DOJ-130 PCB
DOJ-130 PCB
b. Fuse
Name Capacity Function
FS1 7A Safety & Emergency
FS2 7A operation, Car LON
FS3 10A
FS4 10A Hall Net
FS5 10A Hall Lantern
FS6 10A
FS7 3A SMPS1
FS8 1A SMPS2
FS9 5A Door
c. Relays
RRRD Governor Reset relay
RRTD Governor Trip Relay
R7LF Car light control
R1ML Micro Leveling
R7FN Car Fan control
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
6. DPC-140 PCB
6.1. Configuration and Diagram
a. Configuration drawing of DPC-140
Ram
EEPROM
(KM68257*A)
(AM29F010)
ALP Comm.
ASIC
Hall AD
C1CD Drive.
CT
PWM.
Stack Error.
Main CPU
DPRAM Comm.
Motor
& I/O
Thermal.
Brake S/W.
Data &
Address Bus Encoder Encoder.
Interface
DOC-141 PCB
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
DPC-130
VA
VRE
Seg. Function Remark
VA Power(+5,±5, GND)
VRE Rotary Encoder signal 12Vdc :
+5 Vdc (VRE-08 is used) VRE-05 VAD
VB Hall CT
VB
VC Drives C1VD
VD Drives ALP
VE I/O Interface(DOC-110)
VG Connected to DPP-131 VG
VTH VH Serial PC Booting
VDA Connected D/A card Signal test
VTH Motor Thermal
VPW Slack Rope S/W input
VBS Brake S/W input
VPW Power(+24,+28Vdc)
VAD Encoder Signal VH
VBS LED condition
○ Off
⊙ Flickering LED1
● On ALM Red
LED Display Condition Function Remark LED2
VC ALM ○ Normal H/W error CPU Green
● Error is detected Detection
CPU ⊙ Normal CPU Normal:
1 2
○ CPU error Error Flickers
● CPU error Detection 2~3/sec D/A
1 2
VD CARD
Pin No. Function(J5H)
J5H A
1 and 2 Spare
3 and 4 Gen2 Motor 26
25
3 4
VD
Pin No. Function(J1J)
VE
1 and 2 S/W booting
3 and 4 EEPROM write
1 2 J1J
5 and 6 SPEC set
3 4
5 6
Pin No. Function(J1G)
1 and 2 ROM booting
1 2 J1G
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
No. 1 ~ 2 Spare
No. 3 ~ 4 150A 4.1kW~10.3kW.
Setting of J1J
Jumper No. Function Remark
e. Check WDT
a) Verify that CPU LED (Green) flickers at 0.5 second interval with power ON.
b) The LED flickers at 0.25 second interval in motor operation.
Caution: WDT (WATCH DOG TIMER) monitors that the program calculation of speed control
CPU operates properly. If WDT does not flicker at 0.5 second interval during adjustment or it
remains ON or OFF the speed control CPU may seriously fail. Thus every error shall be
inspected thoroughly.
c) In such case, check 5V, ±15V power, ROM or ROM socket error, or connector connection
error.
f. Check ALM LED
a) Verify that LD1 ALM LED (Red) turn ON, and then, OFF after about 2 seconds. ALM
LED is for inverter H/W safety check and turns ON when the followings are detected.
(a) Over current is detected in inverter. (J5H Jumper is not inserted)
(b) WDT of speed control CPU has failed.
(c) U phase arm -short circuit of IPM or GATE SMPS power has failed.
(d) IGBT U-phase ARM is short-circuited and GATE PCB power has failed.
(e) IGBT V-phase ARM is short-circuited and GATE PCB power has failed.
(f) IGBT W-phase ARM is short-circuited and GATE PCB power has failed.
(g) Over current is detected on DC Link end.
(h) Regenerative IGBT and GATE transformer power have failed.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
Caution: If ALM LED turns ON in inputting power and does not turn OFF, operation is
impossible. Perform an inspection according to the above ‘a ~ h’. as shown below.
i) Verify that J5H Jumper is properly inserted.(If not inserted, ALM LED turns ON)
j) Verify that WDT LED is flickering normally.
k) In case of above c) ~ h), check the connectors of DPC-140 PCB and verify that
GATE SMPS, GATE TRANS input is applied by AC 110V+10%,-15%.
l) Check IGBT stack or IPM connection conditions (disconnection and loose bolts)
Caution: If DC Link voltage does not reach 330V even after 8 sec. (Low- voltage error), turn
OFF C1VD contactor and then ON. Then, check the voltage after 8 seconds. If the
voltage is still low, turn OFF the contact and generate charging circuit failure error.
b) In this case, main power circuit connection, GATE SMPS (Trans) input or connection,
charging circuit OFF, IPM, IGBT or regenerative IGBT ON may have failed. Thus, check
these conditions.
7. DPP- 140PCB
7.1. Diagram of DPP-140 PCB
(DPP-140: L-IPM 100A, 150A)
DPP-140
Detects short just like arm short-circuit, IPM & IGBT short within
Detecting short-circuit
5~6㎲ by output short, and outputs an error signal.
Detecting the power voltage Breakdown of power circuit and 15V power is drop to 12±0.5V during power
error failure. It displays error.
IPM class is lower than 100A, it will controlled by DPP-130,131
Driving circuit
(IPM150A : DPP-120,121 / IGBT 200A: DPP-101 )
Detecting error of IPM inner Maintains breakdown condition about 2ms when IPM error occurs
side at its inner side
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
b. Check the connection condition of each connector. Verify that all connectors are
connected to their proper positions.
7.5. Checking of the control power when inputting power
Caution: As DC link voltage (500~700V) is input to DPP-1XX PCB after inputting power,
special attention should be paid to safety.
a. Usually control voltage needs no checking. If any error is found in circuit operation, verify
that GATE SMPS or GATE TRANS input is within AC110±10% and check the connectors.
7.6. Charging (discharging) LED function
a. LED (Red) on PCB lights ON if DC Link voltage is 50V or more and it and dims lights OFF
if the voltage is less than 50V. LED lights ON again when the DC link begins to be
charged with FFB is inputted
Caution: As it takes about 15 seconds for DC Link voltage to be discharged completely
after power OFF, never touch DPP PCB and stack while LED light is ON.
b. When LED does not light ON though main power is inputted, IPM & IGBT short, or
regenerative IGBT OFF error, wrong wiring of recharge resistance (RCR), Recharging
circuit ON error, or luminescent diode may damaged.
Inspection should be carried out after DC link voltage discharged.
z Because the DC Link voltage is fulfilled with power of capacitor, surely check the voltage
for safety.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
b. Check the connection condition of each connector. Verify that all connectors are
connected to their proper positions.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
8. DCL-243 PCB
8.1. Function
※ DCL-243 PCB is car operation PCB(CLON) mounted with MC143150BIFU
neuron chip and is applied to 60∼240m/min.
a. Installed in OPB in single elevator and forms a serial communication network with
CNL LON of E&I PANEL
b. Detects call button in car, open, close and ex_open (elongates door close time for 3
minutes and closes the door regardless of door time with a close button registration)
buttons, control board switch, on car connection box switch input, and car load, and it
transmits them into DOC PCB through network.
c. Controls car call B/T, open, close and ex_open response lamp and Up/Down direction
lamp, full lamp, CPI, and car-chime (gong) with display commands through the network
of DOC PCB.
d. The additional command signals from E&I PANEL that are related with door are
transmitted to DCD PCB. And it receives some error signals of door through parallel
communication for easy installation & maintenance
e. It transmits voice synthesis guide data to the voice synthesis board in OPB through
LCD connector.
f. Functional Classification
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
Voltage +24V±5%
4 DC power
Current TYPE 3 A
5 PCB spec. Size 239×133.3mm
6 Switch SW1 Car operation board ID setting
7 Environment Oper.tem. 0 ℃ ~ 70 ℃
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
LCD : Voice
IND : CPI synthesis guide
connection device(DCV-100)
SW1:ID setting,
terminal resistandce
U1:NEURON
setting
CHIP
U2:DCL
ROM
DFTR : Differen.
trans. input
LAMP:UP,DOWN,
FULL LAMP
CIN:IN-CAR
(OPB)input OP:OPEN
B/T & LAMP
EOP:EX OPEN
B/T & LAMP
ONC:ON-
CAR INPUT CL:CLOSE
B/T & LAMP
BZ1:CALL
B/T BBZZER
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
b. Configuration
Neuron Chip
Serial Network
MAC Comm Port Pulse Trans
ROM 32K
process
CPI driving
RAM 32K Net work
I/O port
process
OPB Input Cage Input
WD Input process
RAM
Power
2K DC24V
Supply DDC
512B Control
Switch
Potensionmeter Input
DOC PCB
Set the terminal resistance
DCL PCB
SC-01,02
CCN-1-01,02 SC-01,03
1 OFF CPU run error, COMM. error No P24V power, PCB(H/W) error, etc.
c. The main OPB ID check by CPI when main power turned on.
a) Check if DCM-11X or 12X is connected to DCL-243 PCB
b) The ID of main OPB "01" will be displayed on DCM-11X or 12X when main power turned
on.
d. COP ID setting in DCL Board
COP ID Dip switch setting
(hex) 1 2 3 4 5 6 7 8
Front Main 1 ON OFF OFF OFF OFF OFF - -
Front Sub 2 OFF ON OFF OFF OFF OFF - -
Wheel chair Main 3 ON ON OFF OFF OFF OFF - -
Wheel chair Sub 4 ON OFF ON OFF OFF OFF - -
Rear Main 5 ON OFF ON ON OFF OFF - -
Rear Sub 6 OFF ON ON OFF OFF OFF - -
th
7 pin : In case the potentiometer is connected, set ‘ON’.
8th pin : Last end of communication DCL board, Set ‘ON’.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
9. TDCV-100 PCB
9.1. TDCV-100 PCB (Auto voice synthesizer device)
a. Function
TDCV-100 PCB is set in OPB as a voice synthesizer. It is composed of CPU (PIC16C63,
PIC16C73), RS232C communication, DA conversion, amplification, and power detection &
battery section.
b. System configuration
※ TDCV-100 PCB configuration
a) Communication method: Parallel Comm,
b) CPU: AT90S2313
c) MEMORY: ROM(27C040) → Voice data stored
d) D-A converter: Converts digital voice data to analog data
e) Amplifier: Amplify analogized data and outputs through speaker
(Max.output: 2Watt, 8Ω )
c. Spec. setting
a) Spec. setting method: Spec. can be modified by DIP SW(SW1).
* Bit allocation chart
Seg
Bit 1~4 Bit 5 Bit 6 Bit 7 Bit 8
.
Refer the below " ON :Chime is
ON : ON :
Func EX)" for operated ON : Announces
Announcement Announcement
tion. underground floor before "Thank you"
for 4F is omitted for 13F is omitted
setting Announcement
1 2 3 4 5 6 7 8
Ex.) In case
underground On
floor is B4
Off
* In case the lowest floor is 1st floor, please turn off DIP SW No. of 1~4
Underground Underground
Dip SW Dip SW
(=lowest) floor (=lowest) floor
※ Once the underground floor is set, other floors are set automatically.
b) Announce recordings in sequence with bits 1~4 turned ON.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
Thus, voice synthesizer can be tested with this bit 1~4 in factory or field.
※ Be sure to turn them OFF after testing.
c) Bit 5 and Bit 6 should set same as floor setting spec. of the building.
d) Bit7 sets addition or deletion of chime before broadcasting depending on user's
requirements.
d) Bit8 sets addition or deletion of 'thank you' message depending on user's requirements.
d. LD1 LED
LED1 : Indicates status of power. Lights ON with power ON
e. Connector Connection
CN1: Detecting of power failure and power source of PCB
CN2: Speaker
CN3: Serial communication connector
CN4: Parallel communication connector
CN2
LCD
DCL-243
CN3
DCV-100
Speaker
d) Verify that BIT6 in DOC PCB (Spec. setting DIP SW) is ON.
e) Verify that data of SPEC address "0034","0036" are"0xFF".
b. Function of Mic
HF2: Hall lantern for No.2 HC2: Hall chime for No.2 HP: Parking
HI2: Indication
for No.2
HI1: Indication
for No.1
d. It drives hall button lamps, indicators, hall lanterns and hall chimes with receiving
output signal form DOC PCB
e. It has a watch dog timer (LED2) that checking CPU down.
f. LED1 checks the communication condition.
g. Function of Mic
HI2: Indication
for upper floor
HI1: Indication
for lower floor
ON
OFF
1 2 3 4 5 6 7 8
SW1 SW2
ON ON
5th
1 2 3 4 5 6 7 8 1 2 3 4 Floor
ON ON
4th
Floor
1 2 3 4 5 6 7 8 1 2 3 4
2nd
ON ON
Floor
1 2 3 4 5 6 7 8 1 2 3 4
- Verify the state of dip switches, which is OFF (state when delivery) before operating.
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
Example2) 7 floor 7 stop, duplex, lift #1 normal hall button, lift #2 disabled button.
[Lift #1 setting] - Set 'A' type hall button as normal call (08E0H ⇒ 83H)
SW1 SW2
Floor DHG-162 installed floor Connection of button
1234 5678 1234
7th floor Installed (For 7th floor) 1110 0000 0000 Connect to 'HD'
6th floor Connect to 'HUC' & 'HDC'
Installed (For 5th, 6th floor) 1010 0000 1000
5th floor Connect to 'HU' & 'HD'
4th floor Connect to 'HUC' & 'HDC'
Installed (For 3rd, 4th floor) 1100 0000 1000
3rd floor Connect to 'HU' & 'HD'
2nd floor Connect to 'HUC' & 'HDC'
Installed (For 1st, 2nd floor) 1000 0000 1000
1st floor Connect to 'HU' & 'HD'
SPEC PCB installed floor 7th 6th 5th 4th 3rd 2nd 1st Data
Data Set Address '0900'H 1 0 1 0 1 0 1 '55'H
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
[Lift #2 setting] - Set 'B' type hall button as normal call (08E4H ⇒ 42H)
SW1 SW2
Floor DHG-162 installed floor Connection of button
1234 5678 1234
7th floor Installed (For 7th floor) 1110 0010 0000 Connect to 'HD'
6th floor Connect to 'HUC' & 'HDC'
Installed (For 5th, 6th floor) 1010 0010 1000
5th floor Connect to 'HU' & 'HD'
4th floor Connect to 'HUC' & 'HDC'
Installed (For 3rd, 4th floor) 1100 0010 1000
3rd floor Connect to 'HU' & 'HD'
2nd floor Connect to 'HUC' & 'HDC'
Installed (For 1st, 2nd floor) 1000 0010 1000
1st floor Connect to 'HU' & 'HD'
SPEC PCB installed floor 7th 6th 5th 4th 3rd 2nd 1st Data
Data Set Address '0908'H 1 0 1 0 1 0 1 '55'H
Power &
Communication
DOT IND
G/A
10.4. Hall connection of Simplex (In case 2 floors are controlled by 1of DHG-162)
DHF-100
HFU
HF HFP
HFD
5F
DHF-100
SW1 DHG-162 HFU
HUC HF1 HF HFP
SW2 HC1 HU
HC2 HD
HI2 HI1
4F
DHF-100
HFU
HF HFP
HFD
3F
DHF-100
SW1 DHG-162 HFU
HUC HF1 HF HFP
SW2 HC1 HU
HC2 HD
HI2 HI1
2F
DHF-100
SW1 of DHG-162 DHG-162 HFU
HUC HF1 HF HFP
HC2 HD
HI2 HI1
1F
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
10.5. Hall connection of Duplex (In case 2 floors are controlled by 1of DHG-162)
DHF-100 DHF-100
HFU HFU
HF HFP HF HFP
HFD HFD
5F 5F
HFU HFU
HF HFP HF HFP
HFD HFD
HFU HFU
HF HFP HF HFP
HFD HFD
3F 3F
HFU HFU
HF HFP HF HFP
HFD HFD
HFU HFU
HF HFP HF HFP
HFD HFD
10.6. Hall connection of through E/L (In case 1 floor is controlled by 1of DHG-162)
SW1
SW2
HFU
HF HFP
HFD
SW1
HUC HF1
HDC HF2
SW2
HC1 HU
5F 5F
HC2 HD HFU
HI2 HI1 HFP HF
HFD
HF1 HUC
HF2 HDC
SW1
HU HC1
4R HD HC2
4F
DHF-100 HI1 HI2
HFU
HF HFP
HFD
DHG-162
SW1
HUC HF1
HDC HF2
HC1 HU SW2
3F 3F
HC2 HD
HI2 HI1 HFU
HFP HF
HFD
HF1 HUC
SW1
HF2 HDC
2F HU HC1
SW2 2R HD HC2
DHF-100
HI1 HI2
HFU
HF HFP
HFD
DHG-162
HUC HF1
HDC HF2
HC1 HU
1F 1F
HC2 HD
HI2 HI1
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
Additional Lamp3
DOT of 1st digit(1 place)
displaying Additional Lamp1
g. Connectors
a) DCM-10X b) DCM-11X, 12X
Name Pin No. Signal Name Pin No. Signal
1 DC24V 1 DC24V
2 GND 2 GND
3 DATA 3 GND
HI HI
4 CLK 4 DATA
5 ENABLE 5 CLK
6 ENABLE
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
P3:1
P4:3
Brake
b. Outward appearance
P4 : -BRB2 SW input
-BAT input
-Brake output
P1 : LDC input
P6 : Annunciator input
P9 : Hand PC connection
(E&I PANEL, DES PCB)
a) MIC
P1 LDC Input P6 Annunciator input
P3 PCB power P7 Car LON Comm. input
BRB2 switch input
Hand PCB connection (E&I
P4 Brake power output P9
PANEL to DES
Battery power input
Hand PCB connection (DES
P5 R.E(rescue) input P10
to Hand)
b) LED
Display condition
No. LED
● Lighting ⊙ Blinking ○ Lights -out
Slower than
1 CON-Speed Normal speed error
Normal speed
2 BAT-Charging Charging OK Battery check No charging
3 BAT- Full Full Charging No Full charging
4 BAT-Fault Battery Fault Battery OK
5 DES-OK CPU error CPU normal CPU error
Operated by battery Operated by E&I
6 BAT-Mode
power PANEL power
Communication Normal Communication
7 LON-OK
error Communication error
GRP operation is
8 GRP GRP operation OK
invalid
Out of ACD27
9 NOR In case of ACD27
mode
Out of inspection
10 INS Inspection operation
operation
Safety line
11 R5SC Safety line normal
abnormal
12 R2LD R2LD On R2LD Off
13 CDS CDS On CDS Off
14 OLS OLS On OLS off
Door open Door open
15 R2OP
command On command Off
Out of door open
16 DZ Door open zone
zone
Part. PCB
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0
c) Button
Button name Full name
CCTL CHCS TEST