Operating Manual: Air Conditioner Wall Mounted Type
Operating Manual: Air Conditioner Wall Mounted Type
Operating Manual: Air Conditioner Wall Mounted Type
English
Wall Mounted Type
Contents
Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-2
Remote Controller Overview and Operations ..................En-3
Timer Operation...............................................................En-5
Human Sensor (Energy Saving) ......................................En-5
General Informations on Operation .................................En-6
Care and Cleaning...........................................................En-7
Troubleshooting ...............................................................En-9
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury to others, or property damage, read this section carefully before you use this product, and be sure to comply following
safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED. This mark denotes an action that is COMPULSORY.
WARNING
• This unit contains no user-serviceable parts. Always consult • If you see lightning or hear thunder, there might be a lightning strike.
authorized service personnel for repairing, installation, and To prevent electric shock hazard, turn off the air conditioner
relocation of this product. by using the remote controller, and do not touch the unit or
Improper installation or handling will cause leakage, electric the power plug during thunderstorm.
shock, or fire. • Do not install the unit in area filled with mineral oil such as a
• In the event of a malfunction such as burning smell, factory or area containing a large amount of splashed oil or
immediately stop operation of the air conditioner, and steam such as a kitchen.
disconnect all the power supply by turning off the electrical • Do not start or stop the operation of this product by inserting
breaker or disconnecting the power plug. Then consult or pulling out the power plug, or by turning on or off the
authorized service personnel. circuit breaker.
• Do not use inflammable gases near the unit.
• Take care not to damage the power supply cable.
If the supply cord is damaged, it must be replaced by the • Do not expose yourself directly to the cooling airflow for many hours.
manufacturer, its service agent or similarly qualified persons • Do not insert your fingers or any other objects into outlet
in order to avoid a hazard. port, open panel, or intake grille.
• Do not operate with wet hands.
• In the event of refrigerant leakage, be sure to keep away from fire
or any flammables, and consult authorized service personnel.
CAUTION
• Provide occasional ventilation during use. • Do not direct the airflow at fireplaces or heating apparatus.
• Always operate the unit with air filters installed. • Do not block or cover the intake grille and the outlet port.
• Ensure that any electronic equipment is at least 1 meter • Do not apply any heavy pressure to radiator fins.
away from either the indoor unit or outdoor unit. • Do not climb on, place objects on, or hang objects from the unit.
• Unplug the power supply cable when not using the indoor • Do not place vase or water container on the unit.
unit for an extended period. • Do not place any other electrical products or household
• After long period of use, check whether the installation stand belongings under indoor unit or outdoor unit.
does not deteriorate to prevent the unit from falling down. Dripping condensation from the unit might get them wet, and
• The airflow direction and the room temperature should be may cause damage or malfunction of your property.
carefully considered when you use this product in a room • Do not expose the unit directly to water.
with infants, children, elderly or sick persons. • Do not use this product for preservation of food, plants,
• This appliance is not intended for use by persons (including animals, precision equipment, art work, or other objects. This
children) with reduced physical, sensory or mental may cause quality deterioration of those items.
capabilities, or lack of experience and knowledge, unless • Do not expose animals or plants to the direct airflow.
they have been given supervision or instruction concerning • Do not drink the drainage from the air conditioner.
use of the appliance by a person responsible for their safety. • Do not pull the power supply cable to disconnect the plug.
Children should be supervised to ensure that they do not • Do not touch the aluminum fins of heat exchanger built-in
play with the appliance. the indoor or outdoor unit to avoid personal injury when you
install or maintain the unit.
3 Front panel 12
7
Power diffuser 1 2 3 4
CAUTION
For appropriate signal transmission between remote controller and Air cleaning filters Filter holders
indoor unit, keep the signal receiver away from the following items:
- Direct sunlight or other strong lights
- Flat-panel television screen
WARNING
In rooms with instantaneous fluorescent lights, such as Take care to prevent infants and young children from acciden-
inverter type ones, the signal may not be transmitted properly. tally swallowing the batteries.
In such a case, consult the store of purchase.
Remote controller holder installation
9 ECONOMY indicator (green)
1 2 3 Slide up
Lights in ECONOMY operation and in 10 °C HEAT operation.
3
4
1 6
5
2 7
7
4
20
6
2 8
19 9
3
18 10
5
17
16 11
15 12 1
14 13
(continued)
5 POWERFUL button Activates the SLEEP timer that helps you to fall asleep comfortably
with gradual temperature control.
Activates the POWERFUL operation.
12 Timer CANCEL button
The unit will operate at maximum power and strong airflow to quickly
cool down or warm up the room. Cancels the set timer.
When activated, the indoor unit will emit 3 short beeps. 13 RESET button
POWERFUL operation is automatically turned off in the following When you press the RESET button, press it gently by using the tip of a
situations: ballpoint pen or other small object in correct direction as shown in this figure.
• Adjusted room temperature reaches the set temperature in COOL,
DRY, or HEAT mode.
• 20 minutes have passed after the POWERFUL operation mode has
been set.
Even in situations above, the POWERFUL operation will not RESET
automatically turn off unless it has run for a certain amount of time.
Notes:
• The airflow direction and the fan speed are controlled automatically. 14 CLOCK ADJUST button See page 3
• This operation cannot be performed simultaneously with ECONOMY Used for adjusting the clock.
operation.
To return to normal operation, press the button again. Then the indoor 15 OFF timer button See page 3
unit will emit 2 short beeps.
Activates the OFF timer.
6 10 °C HEAT button 16 ON timer button See page 5
Starts 10 °C HEAT operation that maintains the room temperature at
Activates the ON timer.
10 °C so as to prevent the room temperature to drop too low.
After pressing the button to start the 10 °C HEAT operation, the 17 SELECT button
indoor unit emits 2 short beeps and the ECONOMY indicator (green)
will turn on. Used for adjusting the clock or timer.
Notes: 18 OUTDOOR UNIT LOW NOISE button See page 3
• In 10 °C HEAT operation mode, only vertical airflow direction can be
Starts or stops OUTDOOR UNIT LOW NOISE operation that lowers
adjusted by using button. noise generated from the outdoor unit by cutting down the rotation
• HEAT mode will not be performed if the room temperature is warm enough.
number of the compressor, and suppressing the fan speed.
• In multi-type air conditioning system, if other indoor unit is in HEAT Once the operation is set, the setting is preserved until you press this button
mode, the temperature of the room where 10 °C HEAT operation is again to stop the operation, even if the indoor unit operation is stopped.
performed will rise. When performing 10 °C HEAT operation, all the on the remote controller display shows that the unit is in
indoor units should be run in 10 °C HEAT operation mode. OUTDOOR UNIT LOW NOISE mode.
To turn off, press the START/STOP button. Notes:
The ECONOMY indicator will turn off.
• This operation cannot be performed simultaneously with FAN, DRY
7 Signal transmitter and POWERFUL operation modes.
• This operation cannot be performed on a multi-type air conditioner.
Aim to signal receiver of the indoor unit properly. If this mode is unintentionally set on a multi-type air conditioner,
• Signal transmit indicator on the remote controller display shows cancel the setting by pressing the button. Otherwise, the signal of
that signal from the remote controller is being transmitted. the remote controller cannot be transmitted properly.
• Operating range is approximately 7 m.
• You will hear a beep if the transmitted signal has been sent properly. 19 ECONOMY button
If there is no beep, press the button on the remote controller again.
Starts or stops ECONOMY operation that saves more electricity
8 FAN button than other operation modes by changing the set temperature to a
moderate setting.
Controls the fan speed. By pressing the ECONOMY button, the ECONOMY indicator on the
indoor unit turns on.
• In COOL or DRY mode, the room temperature will be adjusted a few
degrees higher than the set temperature.
(AUTO) (HIGH) (MED) (LOW) (QUIET)
• In HEAT mode, the room temperature will be adjusted a few
• When AUTO is selected, the fan speed is automatically adjusted degrees lower than the set temperature.
according to the operation mode. • Especially in COOL or DRY mode, you can have improved
dehumidification without significantly lowering the room temperature.
9 SWING button Notes:
Starts or stops automatic swing of the vertical airflow direction louver. • In COOL, HEAT, or DRY mode, the maximum output of this
• Each time you press the button, the vertical airflow direction louver operation is approximately 70 % of usual air conditioning operation.
swings as follows: • This operation cannot be performed during temperature monitoring
by AUTO mode.
COOL, DRY, or FAN • In multi-type air conditioning system, ECONOMY operation is
HEAT or FAN mode performed only on the indoor unit whose ECONOMY button on the
1 mode
2 corresponding remote controller is pressed.
3 1 2 3 4 5 6 7
4
5 20 SENSOR button (ENERGY SAVING) See page 8
6 7
Activates or deactivates the energy saving.
Notes:
* The Energy Saving is ON at the time of purchase.
• SWING operation may stop temporarily when the indoor unit fan is
rotating at very low speed or is stopped. : The setting must be done while the setting screen is displayed for
• In FAN mode, swing operation range of 1 3 or 4 7 is decided each function.
according to the airflow direction previously set before starting the : The button is controllable only when the air conditioner is on.
swing operation.
Timer Operation
Note for timer settings:
Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock incorrect.
In such a case, the TIMER indicator on the indoor unit blinks, and you need to readjust the setting.
Adjust the time by pressing the SELECT button within about 5 2 Adjust the time by pressing the SELECT button within about 5
3 seconds, while the clock indicator is blinking.
seconds, while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to (About 5 seconds later, the remote controller display returns to
standby screen.) standby screen.)
To cancel the timer and return to normal operation, press the CANCEL Each time you press the button, the time changes as follows:
button. 0.5 1.0 2.0 3.0 5.0 7.0 9.0
To redo the timer setting, perform step 2 and 3. (30 min.) hours
Program timer (combined use of the ON timer and the OFF timer) To repeat the timer, press the SLEEP timer button when
indicator is not displayed on the remote controller display.
You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose configured starting time is closer to the To help you to fall asleep comfortably and prevent excessive warming
current time works first, and the order of timer operation is displayed or cooling in sleep, the SLEEP timer controls the temperature setting
as follows: automatically in accordance with the set time shown as follows. The
Timer Indicator on remote controller display air conditioner completely turns off after the set time has elapsed.
In HEAT mode In COOL or DRY mode
ON–OFF timer 1 °C 2 °C 3 °C 4 °C
OFF–ON timer
Set time
The timer that is set later starts counting down after the counting 30 min. Set
down of the preceding timer is finished. temperature 1 hour
1 hour
To set the program timer, conduct the same steps 2~3 for the ON/
1.5 hour
OFF timer. 1 °C 2 °C
Set time
c
c
a
c
b
b
a
b b
a
a 3 Filter holder and air cleaning filter are attached on the rear side
of the air filter. Remove them from the air filter by unlatching each
corner of the filter holder d.
Wash the intake grille gently with water or wipe it gently with a d d
2
soft cloth moisten with warm water.
Then wipe it with a dry and soft cloth.
3 While holding the grille horizontal, set the left and right mounting
shafts into the pillow blocks at the top of the panel a. To latch
each shaft properly, insert the shaft until it snaps.
d d
Then close the intake grille b.
4 Remove dust by using a vacuum cleaner or by washing the filter.
When you wash the filter, use neutral household detergent and
warm water.
a After rinse the filter well, dry it throughly in a shaded place before
a
you reinstall it.
5 Attach the air cleaning filter and the filter holder to each air filter.
6 Attach the air filter with aligning both side of the filter with the front
panel, and push in the filter fully.
Note:
b Make sure that 2 claws are firmly snapped to the guide holes on
b
the panel.
2 Release 2 latches a of the filter holder, and turn over the holder APPLE-CATECHIN FILTER: UTR-FA16
in direction of arrow b.
Remove the soiled air cleaning filter c.
(1 sheet)
Note:
With using static electricity, purifies the air by removing fine particles
Air cleaning filter is attached on each air filter. or dust such as tabacco smoke or plant pollen.
• This filter is disposable. Do not wash or reuse it.
a
• Once you open the package, use it as soon as possible. The
a
cleaning effect is reduced if the filter is left with the package opened.
• Replace the filter once every 3 months under normal use.
• By setting the fan speed high, the air cleaning effect increases.
4 Latch 2 corners of the filter holder e to the air filter firmly. After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
e e FAN operation for half a day to dry the internal parts throughly before
you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the product performance even if you have maintained the unit
with instructed daily care or cleaning procedures written in this manual.
In such a case, the product inspection is recommended.
5 Reinstall the air filter. (Refer to step 6 in “Cleaning the air filter”.)
For more information, consult authorized service personnel.
6 Close the intake grille firmly.
(Refer to step 4 in “Cleaning the intake grille”.)
Troubleshooting
WARNING
In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical
breaker or disconnect the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.
• Unit smells of something burning or emits smoke
• Water leaks from the unit
Following symptoms do not indicate the product malfunction, but they are normal functions or characteristics of this product.
Symptom Cause See page
Operation is delayed after To prevent blowout of the fuse, the compressor will not operate during the protection circuit is working
–
restart. for about 3 minutes after sudden OFF→ON operation of the power supply.
Noise is heard. • During the operation or immediately after stopping the air conditioner, refrigerant flowing sound
may be heard. And it is particularly noticeable for 2–3 minutes after starting operation.
• During the operation, a slight squeaking sound produced by the minute expansion and contraction –
of the front panel caused by temperature change may be heard.
During heating operation, a sizzling sound produced by the automatic defrosting operation may be
6
heard.
Smell coming from the unit. Various room smells generated from interior textile, furniture, or cigarette smoke absorbed into the air
–
conditioner may be emitted.
Mist or steam is emitted from In COOL or DRY mode, a thin mist generated by condensation formed with sudden cooling process
–
the unit. may be emitted.
During heating operation, the fan built-in the outdoor unit may stops and rising steam generated by
6
the automatic defrosting operation may be seen.
Airflow is weak or stops. • Immediately after the heating operation is started, the fan speed stays temporarily very low to warm
up the internal parts of the unit.
• In HEAT mode, the outdoor unit stops and the indoor unit operates at very low fan speed if the –
room temperature rises above the set temperature.
In HEAT mode, the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic
6
defrosting operation while the OPERATION indicator is flashing.
In DRY mode, the indoor unit operates at low fan speed to adjust the room humidity, and may stop
–
from time to time.
When the fan speed is set to “QUIET”, the fan rotates at very low speed and the airflow is reduced. –
In COOL mode, the indoor unit fan may stop from time to time when the outdoor unit is stopped. 3
When monitoring operation is performed in AUTO mode, the fan rotates at very low speed. –
When multiple units are operated in following combination of different operation modes in a multi-
type air conditioning system, the indoor unit operated afterward stops and the OPERATION indicator
flashes. 5
• HEAT mode and COOL mode (or DRY mode)
• HEAT mode and FAN mode
Outdoor unit emits water. During heating operation, the outdoor unit may emit water generated by the automatic defrosting
–
operation.
Before you call for or request servicing, troubleshoot a problem by performing following checks:
Symptom Diagnostic See page
Does not operate at all. Has the circuit breaker been turned off?
Has there been a power outage? –
Has a fuse blown out or the circuit breaker been tripped?
Is the timer operating? 5
Poor cooling or heating perfor- Is the air filter dirty? 6
mance.
Is the intake grill or outlet port of indoor unit blocked? –
Is the room temperature adjusted appropriately? 3
Is a window or door left opened?
Is direct or strong sunlight shinning into the room in cooling operation?
–
Are there other heating apparatus or computers operating, or too many people in the room in cool-
ing operation?
Is the fan speed set to “QUIET”?
When the fan speed setting is set to “QUIET”, noise reduction is prioritized and the air-conditioning
4
performance may become lower. If the volume of provided airflow is not agreeable to your prefer-
ence, set the fan speed to “LOW” or higher fan speed.
The unit operates differently Are the batteries used in the remote controller exhausted?
from the remote controller Are the batteries used in the remote controller loaded properly? 3
setting.
Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or diagnostics.
• The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast.