1. General 1
2. Features 1
3. Technical Specifications 3
4. Construction 5
9. Dimensional Details 15
FEATURES
SALIENT FEATURES
1. Micro-controller based logic.
2. Built in watchdog monitoring design to ensure failsafe
working.
3. Asthetically designed light in weight, with compact
enclosure.
4. Facia windows with long life super bright LEDs.
5. Three operating sequences in single card.
6. Synchronisation of window flashing in group Annun
-ciation.
7. Reliable Membrane type push buttons for Test,
Silence, Accept, and Reset functions.
8. Standard Modules :- 1, 2 ,4, 6, 8, 11, 15, 19 and 23
Windows and any custom built Systems.
9. NO / NC, T / NT , M / N / S Sequence Selection by
DIP Switch at site.
1
ALAN'S SPECIAL FEATURES
1. Easily replaceable window legends.
2. Wide Input Voltage range. i.e. 88 - 350V AC / DC
or 18 - 90V DC.
3. Detection of momentary fault, which may occur
while performing Operational Test .
4. Operational test does not affect the status of the
fault condition, existed before commencing Operation
Test.
5. Online selection settings can be performed.
6. To differentiate Trip and Non Trip faults from facia
itself, "RED"LEDs for Trip and "YELLOW" LEDs
for Non Trip can be provided.
OPTIONAL FEATURES
4
CONSTRUCTION
FRONT FACIA
Customer has choice of two sizes of windows
depending upon their facia description. It is made of
ABS plastic and illuminated by group of super bright
LEDs. LEDs have long life ( 108 hours ). Thus reduces
replacement cost of bulbs and also maintenance.
CONTROL CARD
All type of selections and Micro - Controller are
situated on this card. Sequence selection, NO/NC fault
contacts selection, Trip and Non-Trip audible selection
are provided by DIP Switch selection.
POWER SUPPLY UNITE
Power Supply Unit is available in two ranges.
A) 88-320 V AC/DC
B) 18-90V DC. These power supplies are designed
to work in extreme conditions.
FAULT SENSING TERMINEL
The fault or event sensing terminals provided,
depending upon number of channels at rear side.
PUSH BUTTONS
The built in membrane type Push buttons is
applicable only for Single Module. In multi-module Ann
-unciation the external push buttons are made common
to control whole annunciation system. Terminals for exte
-rnal Push buttons are provided on rear side.
5
AUDIO ALARM
One ‘NO’ type potential free relay contacts each
for actuating the external hooter for Trip and Non Trip
audible alarm. For Trip AT-AT and for Non-Trip AN-AN
legend is marked. ‘NO’ type potential free relay contacts
for Ring back (R) and Dome light facility are optional.
Push
Field Fault Buttons Facia Audio
Condition Condition Operation (Window) Alarm
Normal Open --------- OFF OFF
Abnormal Close --------- Flashing ON
-------- Close Silence Flashing OFF
-------- Close Accept Steady ON OFF
Close Reset Steady ON OFF
------- Open Reset OFF OFF
8
SEQUENCE : Self Reset or Auto Reset "S"
Push
Field Fault Facia Audio
Buttons
Condition Condition Operation (Window) Alarm
9
SPECIAL SEQUENCE "F1, F2, F3" : First Out
Push
Field Fault Facia Audio
Buttons
Condition Condition (Window) Alarm
Operation
Normal Open ------ OFF OFF
10
9. Now initiate individual faults by either shorting
the fault input terminals or by DIP Switch selection.
On doing so every corresponding window should
flash and audio should get ON. Proceed further as
per sequences selected.
11
Push
Up
Pull
Towards
BU
C HH
TR OLZ
IP
12
TESTING FLOW CHART
Steady On condition
Not Glowing
Press Test PB
Check External fuse
All Audio
No No
Windows relay
Flashing Closed
Switch
OFF the
Press Mute PB Supply
Is and
No replace
Fuse
O.K the Fuse
All with same
Windows No No Alarm Rating
OFF Yes
Flashing
Press Accept PB
All
Windows No
Steady Consult Alan
ON
Yes
Press Reset PB
Assumption
NO - Fault Contacts
All
No Manual Reset (M) Seq.
Windows
Off
Note: Power "ON" LED is available only in
Yes Built in Push Button Module.
AKN = MUTE + AKN.
End
(i.e. When Unit is Acknowledged Mute
operation will also take place.)
13
FUNCTIONAL BLOCK DIAGRAM
14
DIMENSIONAL DETAILS
MP 03 SERIES
1 WAY
92
96
96
W1
92
PWR
S A ON
R O
ALAN ALARM ANNUNCIATOR
ELEVATION CUTOUT
2 WAY 1CX2R
92
96
W1
96 W2 92
PWR
S A R O
ON
ELEVATION CUTOUT
4 WAY (2CX2R)
96 92
MP- 03
W1 W2
92
96
ALAN PWR ON
W3 W4
ALAN ELECTRONIC SYSTEMS PVT.LTD.
ELEVATION CUTOUT
15
8 WAY (2CX4R)
144 138
ALAN MP-SERIES
W1 W2
W3 W4
144 138
W5 W6
W7 W8
ELEVATION CUTOUT
12 WAY (3CX4R)
172 168
W1 W2 W3
W4 W5 W6
144 138
W7 W8 W9
W10 W11 W12
ELEVATION CUTOUT
16
DIMENSIONAL DETAILS
MP 02 SERIES
6 WAY (3CX3R)
265 230
MP- SERIES
W1 W2 W3
165 W4 W5 W6 135
PWR
MUTE AKN RST TEST
ON
ELEVATION CUTOUT
8 WAY (3CX3R)
265 230
MP- SERIES
W1 W2 W3
135
165 W4 W5 W6
PWR
W7 W8 MUTE AKN
ON
RST TEST
ELEVATION CUTOUT
11 WAY (3CX4R)
MP- SERIES
W1 W2 W3
W4 W5 W6
W7 W8 W9
PWR
ELEVATION CUTOUT
17
15 WAY (4CX4R)
342 307
MP- SERIES
W1 W2 W3 W4
W5 W6 W7 W8
205 175
W9 W10 W11 W12
PWR
ELEVATION CUTOUT
19 WAY (5CX4R)
342 307
MP- SERIES
W1 W2 W3 W4
W5 W6 W7 W8
W9 W10 W11 W12 245 215
W13 W14 W15 W16
PWR
ELEVATION CUTOUT
23 WAY (6Cx4R)
342 307
MP- SERIES
W1 W2 W3 W4
W5 W6 W7 W8
W9 W10 W11 W12
285 255
W13 W14 W15 W16
W17 W18 W19 W20
PWR
ELEVATION CUTOUT
16
29 WAY (6CX5R)
500
ALAN ALAN ELECTRONIC SYSTEMS PVT.LTD MP- SERIES
W1 W2 W3 W4 W5 W6
CUTOUT
ELEVATION
35 WAY (6CX6R)
500 467
MP- SERIES
W1 W2 W3 W4 W5 W6
W7 W8 W9 W10 W11 W12
W13 W14 W15 W16 W17 W18
275 250
W19 W20 W21 W22 W23 W24
W25 W26 W27 W28 W29 W30
PWR
ELEVATION CUTOUT
47 WAY (8CX6R)
651 621
MP- SERIES
W1 W2 W3 W4 W5 W6 W7 W8
W9 W10 W11 W12 W13 W14 W15 W16
W17 W18 W19 W20 W21 W22 W23 W24
275
W25 W26 W27 W28 W29 W30 W31 W32
W33 W34 W35 W36 W37 W38 W39 W40
PWR
ELEVATION CUTOUT
63 WAY (8CX8R)
651
MP- SERIES
621
W1 W2 W3 W4 W5 W6 W7 W8
W9 W10 W11 W12 W13 W14 W15 W16
W17 W18 W19 W20 W21 W22 W23 W24
W25 W26 W27 W28 W29 W30 W31 W32
355
W33 W34 W35 W36 W37 W38 W39 W40
W41 W42 W43 W44 W45 W46 W47 W48
W49 W50 W51 W52 W53 W54 W55 W56
PWR
ELEVATION CUTOUT
19