User Manual IES-2060 2042FX V1.3
User Manual IES-2060 2042FX V1.3
User Manual IES-2060 2042FX V1.3
Version 1.3
Sep, 2009.
Website: www.oring-networking.com
E-mail: support@oring-networking.com
Table of Content
Hardware Installation.....................................................................................4
2.1 Installing Switch on DIN-Rail.............................................................................................4
2.1.1 Mount IES-2060 & IES-2042FX Series on DIN-Rail ......................................................4
2.2 Wall Mounting Installation..................................................................................................5
2.2.1 Mount IES-2060 & IES-2042FX Series on wall ..............................................................5
Hardware Overview........................................................................................7
3.1 Front Panel ..........................................................................................................................7
3.2 Front Panel LEDs .............................................................................................................10
3.3 Bottom Panel .....................................................................................................................10
3.4 Rear Panel ......................................................................................................................... 11
Cables ...........................................................................................................12
4.1 Ethernet Cables ................................................................................................................12
4.1.1 100BASE-TX/10BASE-T Pin Assignments...................................................................12
4.2 Fibers..................................................................................................................................13
WEB Management........................................................................................14
5.1 Configuration by Web Browser .......................................................................................14
5.1.1 About Web-based Management ......................................................................................14
5.1.2 Basic Setting ...................................................................................................................15
5.1.2.1 Switch setting........................................................................................................16
5.1.2.2 Admin Password ...................................................................................................16
5.1.2.3 IP configuration.....................................................................................................17
5.1.2.4 SNTP Configuration..............................................................................................18
5.1.2.5 LLDP.....................................................................................................................21
5.1.2.6 Backup & Restore .................................................................................................21
5.1.2.7 Upgrade Firmware ................................................................................................22
Hardware Installation
2.1 Installing Switch on DIN-Rail
Each switch has a DIN-Rail kit on rear panel. The DIN-Rail kit helps switch to fix on the
DIN-Rail. It is easy to install the switch on the DIN-Rail:
Metal Spring
Step 2: Push the switch toward the DIN-Rail until you heard a “click” sound.
Step 2: Use 6 screws that can be found in the package to combine the wall mount panel.
Just like the picture shows below:
The screws specification shows in the following two pictures. In order to prevent switches
from any damage, the screws should not larger than the size that used in IES-2060 /
2042FX series.
Pozidrive
Hardware Overview
3.1 Front Panel
The following table describes the labels that stick on the IES-2060 / 2042FX.
Port Description
10/100 RJ-45 fast 10/100Base-T(X) RJ-45 fast Ethernet ports support
Ethernet ports auto-negotiation.
Default Setting :
Speed: auto
Duplex: auto
Flow control : disable
Fiber port 100BaseFX for IES-2042FX switch
Reset Push reset button 2 to 3 seconds to reset the switch.
Push reset button 5 second to reset the switch into Factory
Default.
IES-2060
1. LED for PWR1. When the PWR1 links, the green led will be light on.
2. LED for PWR2. When the PWR2 links, the green led will be light on.
3. LED for PWR3. When the PWR3 links, the green led will be light on.
4. LED for R.M (Ring master). When the LED light on, it means that the switch is the ring
master of O-Ring.
5. LED for Ring. When the led light on, it means the O-Ring is activated.
6. LED for Fault Relay. When the fault occurs, the amber LED will be light on.
7. Reset button. Push the button 3 seconds for reset; 5 seconds for factory default.
8. 10/100Base-T(X) Ethernet ports..
9. LED for Ethernet ports status.
10. Model name
11. 10/100Base-T(X) Ethernet ports..
12. LED for Ethernet ports status.
IES-2042FX Series
1. LED for PWR1. When the PWR1 links, the green led will be light on.
2. LED for PWR2. When the PWR2 links, the green led will be light on.
3. LED for PWR3. When the PWR3 links, the green led will be light on.
4. LED for R.M (Ring master). When the LED light on, it means that the switch is the ring
master of O-Ring.
5. LED for Ring. When the led light on, it means the O-Ring is activated.
6. LED for Fault Relay. When the fault occurs, the amber LED will be light on.
7. Reset button. Push the button 3 seconds for reset; 5 seconds for factory default.
8. 10/100Base-T(X) Ethernet ports.
9. LED for Ethernet ports status.
10. Model name
11. 100BaseFX fiber port.
12. LNK/ACT LED for fiber port.
Cables
4.1 Ethernet Cables
The IES-2060 / 2042FX switches have standard Ethernet ports. According to the link type,
the switches use CAT 3, 4, 5,5e UTP cables to connect to any other network device (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.
The IES-2060 / 2042FX switches support auto MDI/MDI-X operation. You can use a
straight-through cable to connect PC and switch. The following table below shows the
10BASE-T/ 100BASE-TX MDI and MDI-X port pin outs.
4.2 Fibers
The following two models, IES-2042FX-MM, IES-2042FX-SS, have fiber optical ports. The
fiber optical ports are in multi-mode (0 to 2 km, 1310 nm in 50/125 µm, 62.5/125 µm) and
single-mode (9/125 µm) with SC connector. Please remember that the TX port of Switch A
should be connected to the RX port of Switch B.
Switch A
TX RX
Fiber cord
RX TX
Switch B
WEB Management
Note: By default, IE5.0 or later version does not allow Java Applets to open sockets. You need to explicitly
modify the browser setting in order to enable Java Applets to use network ports.
System Login
1. Launch the Internet Explorer.
2. Type http:// and the IP address of the switch. Press “Enter”.
Login screen
Main Interface
Main interface
5.1.2.3 IP configuration
You can configure the IP Settings and DHCP client function through IP configuration.
IP Configuration interface
Daylight Saving Time Enable or disable daylight saving time function. When daylight
saving time is enabling, you need to configure the daylight saving
time period.
UTC Time zone Set the switch location time zone. The following table lists the
5.1.2.5 LLDP
LLDP (Link Layer Discovery Protocol) function allows the switch to advertise its
information to other nodes on the network and store the information it discovers.
LLDP interface
5.1.4 Redundancy
5.1.4.2 O-Ring
O-Ring is one of the most powerful Redundant Ring technology in the world. The
recovery time of O-Ring is less than 10 mS over 250 units of connections. It can
reduce unexpected malfunction caused by network topology change. O-Ring
technology supports three Ring topologies for network redundancy: O-Ring, Coupling
Ring and Dual Homing.
O-Ring interface
2nd Ring Port The backup port, when this switch is Ring Master.
Coupling Ring Mark to enable Coupling Ring. Coupling Ring can be used to
divide a big ring into two smaller rings to avoid effecting all
switches when network topology change. It is a good application
for connecting two O-Rings.
Coupling Port Link to Coupling Port of the switch in another ring. Coupling
Ring need four switch to build an active and a backup link.
Set a port as coupling port. The coupled four ports of four
switches will be run at active/backup mode.
Control Port Link to Control Port of the switch of the same ring. Control Port
used to transmit control signals.
Dual Homing Mark to enable Dual Homing. By selecting Dual Homing mode,
load.
5.1.4.3 Open-Ring
Open-Ring technology can be applied for other vendor’s proprietary ring. Thus, you can
add switches of ORing into the network constructed by other ring technology and enable
Open-Ring to co-operate with other vendor’s managed switch.
Click ”Connect to other vendor’s ring…..” to join the ring constructed by other vendor.
Open-Ring interface
Label Description
Enable Enabling the Open-Ring function
Vender Choosing the venders that you want to join to their ring
1st Ring Port Choosing the port which connect to the ring
2nd Ring Port Choosing the port which connect to the ring
Open-Ring connection
5.1.4.4 RSTP
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol.
It provides faster spanning tree convergence after a topology change. The system also
supports STP and the system will auto detect the connected device that is running STP or
RSTP protocol.
RSTP setting
You can enable/disable the RSTP function, and set the parameters for each port.
Time (4-30) Rapid Spanning-Tree Protocol learning and listening states to the
forwarding state. Enter a value between 4 through 30.
Path Cost The cost of the path to the other bridge from this transmitting
(1-200000000) bridge at the specified port. Enter a number 1 through
200000000.
Priority (0-240) Decide which port should be blocked by priority in LAN. Enter a
number 0 through 240. The value of priority must be the multiple
of 16
Admin P2P Some of the rapid state transactions that are possible within
RSTP are dependent upon whether the port concerned can only
be connected to exactly one other bridge (i.e. It is served by a
point-to-point LAN segment), or it can be connected to two or
more bridges (i.e. It is served by a shared medium LAN segment).
This function allows the P2P status of the link to be manipulated
administratively. True means P2P enabling. False means P2P
disabling.
Admin Edge The port is directly connected to end stations, and it cannot create
bridging loop in the network. To configure the port as an edge
port, set the port to “True”.
Admin Non STP The port includes the STP mathematic calculation. True is not
including STP mathematic calculation. False is including the
STP mathematic calculation.
Apply Click “Apply” to activate the configurations.
NOTE: Follow the rule to configure the MAX Age, Hello Time, and Forward Delay Time:
2 x (Forward Delay Time value –1) ≥ Max Age value ≥ 2 x (Hello Time value +1)
RSTP Information
Show RSTP algorithm result at this table.
5.1.6 VLAN
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which
allows you to isolate network traffic. Only the members of the VLAN will receive traffic
from the same members of VLAN. Basically, creating a VLAN from a switch is logically
equivalent of reconnecting a group of network devices to another Layer 2 switch.
However, all the network devices are still plugged into the same switch physically.
The switch supports port-based VLAN only.
5.1.7 Warning
Warning function is very important for managing switch. You can manage switch by
SYSLOG, E-MAIL, and Fault Relay. It helps you to monitor the switch status on remote
site. When events occurred, the warning message will send to your appointed server,
Protocol.
Reset switch to default configuration. Click Reset to reset all configurations to the
default value. You can select “Keep current IP address setting” and “Keep current
username & password” to prevent IP and username & password from default.
Technical Specifications
Technology
Ethernet Standards IEEE802.3 10BASE-T
IEEE802.3u 100BASE-TX
IEEE802.3x Flow Control and Back pressure
IEEE802.1D Spanning tree protocol
IEEE802.1w Rapid Spanning tree protocol
IEEE802.1AB LLDP
MAC addresses 2048
Flow Control IEEE 802.3x Flow Control and Back-pressure
VLAN Port based
Processing Store-and-Forward
Firmware upgrade TFTP
Ring redundancy STP
RSTP
O-Ring
Open-Ring
Fast recovery
Interface
RJ45 Ports 10/100Base-T(X), Auto MDI/MDI-X
Fiber Ports 100 Base-FX(SC Connector)
Multi-Mode:
0 to 2 km, 1310 nm (50/125 µm to 62.5/125 µm)
Single-Mode:
0 to 30 km, 1310 nm (9/125 µm)
LED Indicators Per Unit : Power x 3(Green)
RJ45 Ports:
Per Port : Link/Activity(Green/Blinking Green), Full
LINK(Amber)
Fiber Ports:
Per Port : Activity(Green), Link (Amber)
Power Requirements
Power Input Voltage PWR1/2: 12 ~ 48V DC on 7 pin Terminal block
PWR3: 12 to 45VDC on Power Jack