Medium Voltage Metal Clad Switchgear: Solution Power
Medium Voltage Metal Clad Switchgear: Solution Power
Medium Voltage Metal Clad Switchgear: Solution Power
Medium Voltage
Metal Clad Switchgear
Contents
● Features 12
● Ratings 14
● Ratings for double lever 16
● Structures and dimensions 17
● S
tructures and dimensions
for double lever 18
● Accessories and apparatuses 20
● Arrangement
(for general application) 24
2I
LSIS showing the new, innovative products every customer desires
to present standards for the future electric power solution as leading
industrial electrical / electronic sectors with developing high-tech.
I3
Vacuum Circuit Breaker, VCB is installed in the medium voltage distribution
lines to protect life and load equipment. In case of accidents such as over
current, short circuit and ground fault current, VCB works by interrupting the
circuit through the inner Vacuum Interrupter which is acted by signal from the
outside separate relay.
Suitable for use as the main circuit breaker to protect key installations in the
places such as device industry, power plants, high-rise buildings, large ships.
4I
▶ Strengthening of the high interrupting capacity and large current
models and full line-up new VCB models to high/middle/low.
Voltage Interrupting current Rated current
7.2kV 8/12.5/20/25/31.5/40/50kA 400/630/1250/2000/3150/4000A
12kV 20/25/31.5/40/50kA 630/1000/1250/2000/2500/3150/4000/5000A
17.5kV 20/25/31.5/40/50kA 630/1000/1250/2000/2500/3150/4000A
24kV 12.5/25/31.5/40kA 630/1250/2000/2500/3150A
25.8kV 12.5/16/25/31.5/40kA 630/1250/2000/3150A
36kV 25/31.5/40kA 1250/2000/3150A
I5
7.2kV (VL-06)
•Rated short-time (for withstand current ): 3sec.
•Rated operating sequence: O-0.3s-CO-15s-CO
•Type test level: M2, E2 (List1), C2
•100% Compatibility
- with existing fixed type breakers
- with existing drawout type breakers
•Various cradle: E, F and G type
•A variety of control power
- DC 24~30V, DC 48~60V, DC 110V, DC 125V, DC 220V
- AC 48V, AC 100~130V, AC 220~250V
•A variety of accessories
- Charge switch, UVT, Secondary trip Coil, Current trip coil,
Position S/W
- Key-lock, Button lock, Button cover, Padlock, UVT, Time
Delay Controller, CTD
•Anti Pumping Device
•TEST/SERVICE Automatic Position Indicator
•Standards and certification
- IEC62271-100 (2012) [M2, C2, E2 (List1)]
- Tested in enclosure
- KERI type tested, V-check (KESCO) certification
Ur Isc Ir
(kV) (kA) (A)
7.2 8 400
12.5 630
E type
F type
H type I7
Main circuit structure
with high reliability
Susol
VCB
Breaker
Insulation rod
Lower terminal
Shunt
Vacuum interrupter
Upper terminal
Tulip contactor
Fixed
electrode
Fixed
Contacts
seal cup Vacuum Interrupter, VI
Arc shield
The vacuum rate within the VI is very high the contacts are made of special alloy (copper-
Bellows (approximately 5x10-5 Torr) and the spacing chromium) and the interior is completely sealed
shield
Ceramic between fixed contact and movable contact to prevent loss of vacuum.
is about 6~20mm, depending on the Therefore the wearing of the contacts can be
Bellows
voltage. minimized in the event of short-circuit and the
Movable
Movable seal cup The contacts are in a structure that arc can arc energy by overvoltage or switching can be
electrode
easily be extinguished and the surfaces of reduced effectively.
8I
< < Susol VCB Series
Convenience and
Variety
I9
Stego Tulip
Main circuit structure with high reliability
•Maximizing the durability and reliability of the main circuit contactors (Stego Tulip contactor)
•Strong structure for the temperature rise (Natural cooling system)
Tulip finger
Tulip spring
Plate understar :
Securing freedom of Tulip
Plate star: Supporting Tulip for position maintaing and torsional flow prevention
10I
< < Susol VCB Series
7.2/12/17.5/24/25.8/36kV...
(VH-06/12/17/20/25/36)
I 11
Solution Power Series
Features
Installation
2,350
2,350
2,350
2,350
space
Incoming Incoming
VCB + PT
Feeder
VCB
VCB
Feeder
+ PT VCB
2,
00
0
2,
00
0
64%
reduced
Incoming Incoming
VCB
Main
VCB
PT
Main
Feeder
PT
VCB
Feeder
VCB
50
0
50
0
2, 2,
800 800
800 800 1,200 1,200
1,200 1,200
1,200 1,200
Safety considerations
This Solution Power switchgear provides the best protection rating out of Air Insulated Switchgear !!
Designed to remove explosion or damage to peripheral devices as possible in the event of internal arc happening
.To prove its reliability and safety LSIS use the internationally recognized testing agency, KERI / KEMA / CESI for
certification as well as LSIS' test lab PT&T that is a KOLAS-qualified (Korea Laboratory Accreditation Scheme)
accredited testing laboratory and provides worldwide testing service.
•Metal clad type: each compartment is divided by metal partitions for the highest degree of protection rating out
of Air Insulated Switchgears.
•Short-circuit, short-time current and internal arc tests passed at KERI / KEMA / CESI by IEC 62271-200.
•Various options including
- Mechanical interlock to prevent from inadvertent operating
- Mechanism enable the breaker to be drawn in or out without opening the door
- Position padlock to lock the breaker at the present position.
•Solid structure with hinge and locker
•IP Cover on the face of the breaker and inspection window on the door
•Metal shutter and shutter padlock installed in CB compartment for safe maintenance
•Used reliable tube & boots for busbar insulation
•Insulation cap and padlock used for earthing switch to secure insulation and safety
•CT equipped with protective insulation wall
•Inhouse test equipment with 1,500 MVA capacity for performing reliability test
12I
Convenient maintenance and inspection
Preventive maintenance is essential for all switchgears.
LSIS' One-Stop Total preventive maintenance activities cover continuous maintenance, inspection, remaining life
expectancy and streamline. Solution Power Switchgear is structured for these convenient maintenance and
inspection.
•Using recently developed Susol VCB for almost unnecessary maintenance and inspection .
•Low voltage compartment provides enough space to test and change the internal wiring easily, and the wiring
duct at the top of it is made of steel material .
•Independent bus compartment structured not to affect any accident to adjacent panels .
I 13
Solution Power Series
Ratings
14I
17.5kV Metal Clad Switchgear Specification
Section Contents
I 15
Solution Power Series
16I
Structures and dimensions
H
H
H
H
H
H
D W
DD WW
D W
D W
D W
D W
50
50
15
65 d-130 65
550
W
550
W
50
550
d-130
6565 6565
W
d-130
65 d-130 65
50
550
65 d-130 65
550
65 d-130 65
D
550
65 d-130 65
DD
D
D
D Base detail
D
I 17
Solution Power Series
G116
D116
A116
G30
D30
A30
G263.5
A263.5
D263.5
G20
D20
A20
D4
E64.5 E53.8
B20
E4
E86
55
P1
E50
B196.2
E3
60
.5
E4 10x14
V1 V1 V1
2700
A20 A20
B20
40 2320 40
2400 800
NP
VCB(Susol)
1250A(50KA)
P=210
G R
2400
NP
G R
VCB(Susol)
2000A(50KA)
P=210
Side
Arc
Duct
50
2400 1000
18I
Ventilation Cover Bus Compartment
■ Independent bus compartment
structured not to affect any accident
to adjacent panels .
I 19
Solution Power Series
Interlocking device
between door and C.B.
Inspection window
When the C.B. is service position,
Viewing window permits view of customer can not open the door
the status of the breaker through without releasing the interlock key.
the closed door.
20I
Vacuum circuit breaker
LS Susol VCB is user-friendly to give more convenience and safety by providing high speed interrupting time (3cycles), adopting
the rapid auto reclosing method, and having wide range of accessories.
CB Compartment Option
Mechanically Operated Earthing Switch Position
Cell switch (MOC) Switch
Auxiliary switch, which is The auxiliary switch (5a5b) to
mechanically operated in 'Run' indicate 'ON' or 'OFF' of the
position, indicates 'ON' or 'OFF' earthing switch.
condition of the breaker.
I 21
Solution Power Series
Current Transformer
28
28
162.5
28
28 28
150
355
100
50
100
150
28
162.5
162 5
28
28
28
1250A to 2000A
(Primary current) 1250A to 2000A
(Primary current)
12 5
17.5
160 200
200 220
112 122
50
50
370
0
320
20
EARTH EARTH
TERMINAL TERMINAL
(M6)
(M6)
22I
Voltage Transformer
•Compact and concentrated fuse holder of Y24F can be easily applied to the VTS
compartment
•Mounting type
•Compact and epoxy molded for superior insulation and maintenance free
605 138
A
H1
285
240
NAMEPLATE
599
2
240 25
304.5
130
108
DIA 11
325
I 23
Solution Power Series
(Withdrawable VT)
(Withdrawable VT)
(Withdrawable VT)
Section view
Diagram
Note) Panels except Incoming panel and Feeder panel to be applied those of a general switchgear.
24I
(Withdrawable VT)
(Withdrawable VT)
(Withdrawable VT)
Section view
Diagram
I 25
Solution Power Series
Memo
26I
www.lsis.com