Epoxy Paint
Epoxy Paint
Epoxy Paint
Description: HEMPEL’S EPOXY RESIN 05500 is a solvent-free, two-component, high build polyamine
cured epoxy paint, which cures to a coating with excellent resistance to fresh water, sea
water, oil cargoes and to abrasion.
Recommended use: As resin for a coating system which, in combination with glassfibre mats ("hand lay-up"
system), is used for re-bottoming of steel storage tanks or for reinforcing the interior of
concrete storage tanks.
PHYSICAL CONSTANTS:
Colours/Shade nos: Transparent/00000
Finish: Glossy
Volume solids, %: 100
Theoretical spreading rate: 2 m²/litre - 500 micron
81.5 sq.ft/US gallon - 20 mils
Flash point: > 100°C/212°F
Specific gravity: 1.1 kg/litre - 9.2 lbs/US gallon
Through dry: 24 (approx.) hours at 20°C/68°F
Fully cured: 7 days at 20°C/68°F
The physical constants stated are nominal data according to the HEMPEL Group's approved formulas. They are
subject to normal manufacturing tolerances and where stated, being standard deviation according to ISO 3534-1.
APPLICATION DETAILS:
Mixing ratio for 05500: Base 05509 : Curing agent 98500
1.8 : 1 by volume
Application method: Roller/brush (See separate APPLICATION INSTRUCTIONS)
Thinner (max.vol.): Do not dilute
Pot life: 4 hours (20°C/68°F)
Cleaning of tools: HEMPEL’S TOOL CLEANER 99610
Indicated film thickness, dry: 500 micron/20 mils (see REMARKS overleaf)
Indicated film thickness, wet: 500 micron/20 mils
Recoat interval, min: 24 hours (20°C/68°F)
Recoat interval, max: 3 days (20°C/68°F)
Safety: Handle with care. Before and during use, observe all safety labels on packaging and
paint containers, consult HEMPEL Material Safety Data Sheets and follow all local or
national safety regulations. Avoid inhalation, avoid contact with skin and eyes, and do
not swallow. Take precautions against possible risks of fire or explosions as well as
protection of the environment. Apply only in well ventilated areas.
APPLICATION Use only where curing can proceed at temperatures above 10°C.
CONDITIONS: The temperature of the substrate and the paint itself should be above 15°C to secure proper
application properties.
Apply on a dry and clean surface with a temperature above the dew point to avoid condensation.
PRECEDING None, HEMPADUR SEALER 05990 or HEMPADUR 15590.
COAT:
REMARKS:
Weathering/service The natural tendency of epoxy coatings to chalk in outdoor exposure and to become more
temperatures: sensitive to mechanical damage and chemical exposure at elevated temperatures
is also reflected in this product.
Film thickness: May be specified in another film thickness than indicated, depending on purpose and area of use.
This will alter spreading rate and may influence drying time and recoating intervals.
Normal range dry is 300-600 micron/12-24 mils. Further reference is made to the separate
APPLICATION INSTRUCTIONS.
Recoating: If the maximum recoating interval is exceeded, roughening of the surface is necessary to ensure
intercoat adhesion.
Before recoating after exposure in a contaminated environment, clean surface thoroughly with high
pressure fresh water hosing and allow to dry.
Note: HEMPEL’S EPOXY RESIN 05500 is for professional use only.