10-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT
10-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT
10-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
10-Port Antenna
Electrical Downtilt
° 2.0 – 14.0
continuously adjustable
Tilt Accuracy ° < 0.4 < 0.4 < 0.4 < 0.5 < 0.4
First Upper Side Lobe
dB > 17 > 19 > 19 > 20 > 18
Suppression
Upper Side Lobe
Suppression, 20° Sector dB > 16 > 16 > 16 > 18 > 14
above Main Beam
Cross Polar Isolation dB > 28
Port to Port Isolation dB > 30 (Y2 // R1, Y1, Y3, Y4)
Max. Effective Power W 200 (at 50 °C ambient temperature)
per Port
Max. Effective Power W 400 (at 50 °C ambient temperature)
Port 5–6
Values based on NGMN-P-BASTA (version 9.6) requirements.
Electrical Downtilt
° 2.0 – 14.0
continuously adjustable
Tilt Accuracy ° < 0.4 < 0.4 < 0.5 < 0.4 < 0.4
First Upper Side Lobe
dB > 18 > 18 > 17 > 17 > 16
Suppression
Upper Side Lobe
Suppression, 20° Sector dB > 18 > 18 > 17 > 17 > 15
above Main Beam
Cross Polar Isolation dB > 28
Port to Port Isolation dB > 30 (Y4 // R1, Y1, Y2, Y3)
Max. Effective Power W 200 (at 50 °C ambient temperature)
per Port
Max. Effective Power W 400 (at 50 °C ambient temperature)
Port 9–10
Values based on NGMN-P-BASTA (version 9.6) requirements.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
10-Port Antenna
3)
1)
Remarks Weight Units per
Type No. Description
mm | inches approx. kg | lb antenna
85010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 2
85010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2
85010008 1 downtilt kit Downtilt angle: 0° – 10° 4.3 | 9.5 1
86010154 Site Sharing Adapter 3-way (see figure below) 0.65 | 1.4
86010155 Site Sharing Adapter 6-way (see figure below) 1.35 | 3.0
86010162 Gender Adapter Solely to be used in combination with 0.045 | 0.099 1
86010163 Port Extender the FlexRET module 86010153V01 0.16 | 0.35 1
1995 | 78.5
2022 | 79.6
2062 | 81.2
Accessories (included in the scope of supply)
738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 2
86010153V01 FlexRET 1
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
Material: Reflector screen: Aluminum.
Fiberglass housing: It covers totally the internal antenna components. The special
936.5290/a ngmn 04.21.01.04 Subject to alteration.
design reduces the sealing areas to a minimum and guarantees the best weather
protection. Fiberglass material guarantees optimum performance with regards to stability,
stiffness, UV resistance and painting. The color of the radome is light grey.
All nuts and bolts: Stainless steel or hot-dip galvanized steel.
Grounding: The metal parts of the antenna including the mounting kit and the inner conductors are
DC grounded.
1) 9 | 0.4
Configuration example Configuration example 2) 72 | 2.8
with Site Sharing Adapter 86010154 with Site Sharing Adapter 86010155 3) 13 | 0.5
FlexRET FlexRET FlexRET FlexRET FlexRET FlexRET All dimensions
in mm | inches
Layout of interface:
Left Right
Y1 Y1 Y3 Y3
169 | 6.7 *
Y2 Y2 R1 R1 Y4 Y4
104 | 4.1
6 5 2 1 10 9
54 | 2.1
124 | 4.9
224.5 | 8.8
325 | 12.8
377 | 14.8 *
Bottom view
* Dimensions refer to radome
All dimensions in mm | inches
Correlation Table
Frequency range Array Connector
Y1 Y3
R1
Left Right
Order Information
Model Description
80010891 10-Port antenna with mounting bracket
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
FlexRET
A flexible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas.
Please note:
If the Primary which controls the FlexRET system does not support the default ex-factory interface
setting, then the FlexRET must be switched to the appropriate standard of the Primary before installation.
Please contact Kathrein for further information.
If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antenna
after power on automatically. It is not necessary to configure the FlexRET manually.
Standards: EN 60950-1 (Safety)
EN 60950-22 (Safety – Equipment installed outdoor)
EN 55022 (Emission)
EN 55024 (Immunity)
ETS 300019-1-4 (Environmental)
UL 60950-1; 1st edition
Certification: CE, FCC
Scope of supply: FlexRET
Optional: Site Sharing Adapter (86010154 or 86010155) to create independent logical
Subject to alteration.
chain capability.
Detailed information is given in the data sheet of the Port Extender.
Please note:
In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is
manually addressed, the serial number has to be extended by the corresponding colour coding
extension (e.g. CSG351234-R1). The respective information can be found on the site documentation
which is
included in the scope of supply.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
FlexRET
Startup of FlexRET
The FlexRET module included in the antenna is preconfigured with the following information:
Antenna model no., Antenna Serial no., Antenna configuration data. After connecting a control
cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.)
will find the FlexRET. You only need to insert your additional data.
Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for fixing the
connector must be 0.5 – 1.0 Nm (‘hand-tightened’).
The connector should be tightened by hand or by a special torque screw driver (order no.
85010080).
See also data sheet for Kathrein AISG-cable (86010007, ...).
Please note: To ensure the tightness of the RET System, Kathrein recommend the use of
Kathrein components only.
Please note: If the daisy chain output is not used, do not remove the protection cap.
For daisy chain operation, remove the protection cap and attach a control cable to interconnect
with the daisy chain input of the subsequent FlexRET or external RCU.
Please note: Do not remove the protection cap on the daisy chain output of the last F lexRET
or RCU device.
Subject to alteration.
936.5204/b
FCC – Statements
FCC § 15.19
This
device
complies
with
Part
15
of
the
FCC
rules.
Operation
is
subject
to
the
following
two
conditions:
(1)
This
device
may
not
cause
harmful
interference,
and
(2)
this
device
must
accept
any
interference
received,
including
interference
that
may
cause
undesired
operation.
FCC § 15.105
Note:
This
equipment
has
been
tested
and
found
to
comply
with
the
limits
for
a
Class
B
digital
device,
pursuant
to
part
15
of
the
FCC
Rules.
These
limits
are
designed
to
provide
reasonable
protection
against
harmful
interference
in
a
residential
installation.
This
equipment
generates,
uses
and
can
radiate
radio
frequency
energy
and,
if
not
installed
and
used
in
accordance
with
the
instructions,
may
cause
harmful
interference
to
radio
communications.
However,
there
is
no
guarantee
that
interference
will
not
occur
in
a
particular
installation.
If
this
equipment
does
cause
harmful
interference
to
radio
or
television
reception,
which
can
be
determined
by
turning
the
equipment
off
and
on,
the
user
is
encouraged
to
try
to
correct
the
interference
by
one
or
more
of
the
following
measures:
This
device
complies
with
Industry
Canada
licence-‐exempt
RSS
standard(s).
Operation
is
subject
to
the
following
two
conditions:(1)
this
device
may
not
cause
interference,
and
(2)
this
device
must
accept
any
interference,
including
interference
that
may
cause
undesired
operation
of
the
device.
Le
présent
appareil
est
conforme
aux
CNR
d'Industrie
Canada
applicables
aux
appareils
radio
exempts
de
licence.
L'exploitation
est
autorisée
aux
deux
conditions
suivantes
:
(1)
l'appareil
ne
doit
pas
produire
de
brouillage,
et
(2)
l'utilisateur
de
l'appareil
doit
accepter
tout
brouillage
radioélectrique
subi,
même
si
le
brouillage
est
susceptible
d'en
compromettre
le
fonctionnement.
Subject to alteration.
ICES-‐003
Cet
appareil
numérique
de
la
classe
B
est
conforme
à
la
norme
NMB-‐003
du
Canada.
936.5204/b
[Any]
changes
or
modifications
not
expressly
approved
by
the
party
responsible
for
compliance
could
void
the
user’s
authority
to
operate
the
equipment.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
FCC – Statements
Type of equipment:
EU-RED
Hereby, Kathrein Werke KG declares that the radio equipment type 86010153V01 is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet
address: http://www.kathrein.com
Subject to alteration.
936.5204/b
152 [5.98]
100 [3.94]
[0.79–0.98]
40 [1.57]
72 [2.83]
20–25
40 [1.57]
15
2–1
4 4.53]
5–
[1.6
M10 MA = 25 Nm
M8 MA = 20 Nm
35 [1.38]
64 [2.52]
125 [4.92]
20–25
[0.79–0.98]
Subject to alteration.
936.3920/c
Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm and [inches]
The additional nuts supplied are only meant as spares.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
General Instructions
for Feeder Line Installation
for Antennas with 4.3-10 Connectors
Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.
Left/right marking
of array positions
FlexRET module
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
General Information
about Panel Antennas
Environmental Kathrein cellular antennas are designed to operate under the environmental conditions
conditions: as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
– Low temperature: –55 °C
– High temperature (dry): +60 °C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.
Ice protection: Due to the very sturdy antenna construction and the protection of
the radiating system by the radome, the antenna remains operational even under icy
conditions.
Environmental Kathrein antennas fulfil the stated specifications after completion of the environmental
tests: tests as defined in ETS 300 019-2-4. The homogenous d esign of Kathrein’s antenna
families uses identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.
Please note: As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary operating conditions.
The details given in our data sheets have to be f ollowed carefully when installing
the antennas and accessories.
Site planning and installation must be carried out by qualified and experienced
staff. All relevant national safety regulations must be upheld and respected.
Incorrect site planning, faulty installation, as well as interfering surroundings
on site, may lead to deviations in the electrical parameters compared to those
specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the compatible
counterpart. Please ensure that the connected cable has been fitted with a
connector of the same standard, otherwise damage may occur.
The tilt values will be set to any arbitrary value in the given tilt range. These values
Subject to alteration.
are independent from the frequency band or antenna type and can vary between
antennas and bands.
EU-RED Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: http://www.kathrein.com
936.4694/d
Our quality assurance system and our RoHS Our products are compliant to the
environmental management system apply EU Directive RoHS as well as to other
to the entire company and are certified environmentally relevant regulations
by TÜV according to EN ISO 9001 and (e.g. REACH).
EN ISO 14001.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com