Datasheet PDF
Datasheet PDF
Datasheet PDF
Semiconductors SC8560
DIGITAL ALARM CLOCK
DESCRIPTION
The SC8560 is an alarm equipped digital clock IC with built-in
drivers capable of directly driving LED display equipment. SOP-28
FEATURES
* Single chip P-channel ED MOS LSI
* LED direct drive using time division (duplex configuration)
* Wide operating power supply voltage range
* Built-in alarm function with 24-hour control
* Supports changeover between 12-hour AM/PM and 24-hour SDIP-28
displays
* Built-in battery backup CR oscillator
* Built-in automatic fast forward function for hour and minute
settings ORDERING INFORMATION
* Built-in snooze function supporting repeat use Part No. Package
* Uses 50Hz as standard frequency SC8560 SDIP-28-400-1.778
* Built-in sleep timer function (maximum intervals for 59 minutes or SC8560S SOP-28-375-1.27
1 hour and 59 minutes)
* Equipped with power failure display function APPLICATIONS
* 900Hz output for alarm tone * Alarm clocks
* Clock-radios
PIN CONFIGURATIONS
AM & 10'S HR ag & de 1 28 12/24 HR SELECT
21 S. Sample 4 HR b&g
Set
Input
Control Sec
Hour F. Sample Time MIN. CTR Time HR. CTR 5 HR c&d
22
Set
2Hz
Time & S. Sample Time & F. Sample 6 HR a&f
Reset Sec RSTYHLD Time
Control T. RST Comparator
2
AL. RST
PWR UP
7 10'S MIN a&f
PWR UP
Alarm 8 10'S MIN b&g
19 SEC Disp Alarm MIN CTR Alarm HR. CTR Alarm
Display T. Disp
AL. Disp
Output Decoder/Driver
Control
Display
Sleep SL. Disp
23
Display
Sleep CTR Sleep
10 10'S MIN e& Min e
PWR
UP
11 Min b&g
display
Second
Control
Rev: 1.1
Output OFF Output Output
SC8560
2003.06.26
Silan
Semiconductors SC8560
ABSOLUTE MAXIMUM RATINGS(Ta =25°C, Vss =0V)
Characteristic Symbol Condition Value Unit
Maximum Supply Voltage VDD max. -15.0 ~ + 0.3 V
Input Voltage 1 VIN(1) 50/60Hz input -15.0 ~ + 0.3 V
Input Voltage 2 (except pin 26) VIN(2) Except 50/60Hz input -15.0 ~ + 0.3 V
Output Voltage VOUT -15.0 ~ + 0.3 V
Input Clamp current( pin 26) IIN 50/60Hz input -0.4 ~ +0.4 mA
Allowable Power Dissipation PD Ta=70°C 700 mW
Operating Temperature Topr -30 ~ +70 °C
Storage Temperature Tstg -55 +125 °C
(To be continued)
DESCRIPTION OF OPERATIONS
Terminal Description Operating Description
Built-in Shumidt circuit enable noise elimination at 50/60Hz commercial
50/60 Hz Input:
frequencies with use of a simple CR filter. Built-in pull-up resistor.
When the AC power supply is interrupted, the time counter switches to a holding
state and a built-in oscillator promptly begins operation. If 50/60Hz input
continuous for 3 clocks without arriving, this oscillator’s output is activated and
functions as the time counter clock in place of 50/60Hz input. The frequency level
CR Input of this clock oscillator is determined according to the CK Value. While the above
mentioned oscillator is operating using backup mode, all segment output is
switched to OFF. (Note) When the backup oscillator is in use due to an AC power
supply interruption, the 50/60Hz input pin must be maintained open or at a Vss
level.
When 50/60 selective input is connected to Vss,50Hz use is enable. When 50/60
50/60Hz Selective Input selective input is left open, VDD is activated using an internal pull-down resistor
and the setting is switched to enable use at 60Hz.
Since the pull-down resistor is built-in, selection from four display modes is
Display Mode Selective Input
possible using two SPST switches (single-pole and single-throw switches). Table l
(Alarm Select/Sleep Select )
shows these display mode selections.
There are two setting inputs for use with “hour” and “minute”. Time content
Time Setting Input settings shown in Table 2 are possible by activating Vss to these pins. A pull-down
resister is built-in.
Leaving this pin unconnected (VDD) causes the 12-hour basis to be selected,
12/24H Select Input connecting this pin to VSS cause the 24-hour basis to be selected .An internal pull-
down resistor is provided.
(To be continued)
Note:
When the digital reading for seconds is between 30 and 59 seconds, 1 is added to digits for minutes as the
digital reading for seconds resets to [00]
12HR 60Hz
2.2kȍ
4.7kȍ
NC NC
0.47μF
28 27 26 25 24 23 22 21 20 19 18 17 16 15
Semiconductors
12/24 CR 50/60Hz 50/60Hz Snooze Sleep HOUR MIN Alarm Alarm Sleep Alarm
Backup HR Input Select Input Input Input V DD Vss
Set Set Disp Off Out Out
Battery Select
100kȍ
SC8560
AM & PM & 10'S 10'S 10'S 10'S 10'S
HR HR HR MIN MIN MIN Colon
10'S HR 10'S HR c & MIN MIN MIN MIN e &
b&g c&d a&f b&g c&d a&f Out
ag & de HR b HR c a&f b&g c & d MIN e
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Duplex LED
a
f b
AC NOTE: 1
g
e c
Cycle 1
d
Cathode
Common 2
Cycle 2
This circuit is used as noise interference
stripper for the LW band.( Backup control
CLOCK-RADIO APPLICATION CIRCUIT (Positive Power Supply)
2003.06.26
Piezo Buzzer
Silan
C1
R1
110kȍ
0.015μF
330μF
f=900Hz
12HR 60Hz
NC NC
Semiconductors
0.001μF
28 27 26 25 24 23 22 21 20 19 18 17 16 15
12/24 CR 50/60Hz 50/60Hz Snooze Sleep HOUR MIN Alarm Alarm Sleep Alarm
HR Input Select Input Input Input V DD Vss
Set Set Disp Off Out Out
Select
100kȍ
SC8560
AM & PM & 10'S 10'S 10'S 10'S 10'S
HR HR HR MIN MIN MIN Colon
10'S HR 10'S HR c & MIN MIN MIN MIN e &
b&g c&d a&f b&g c&d a&f Out
8
ag & de HR b HR c a&f b&g c & d MIN e
1 2 3 4 5 6 7 8 9 10 11 12 13 14
f b
AC NOTE: 1 g
e c
Cycle 1
d
Cathode Common
CLOCK APPLICATION CIRCUIT (Negative Power Supply)
2
When Battery backup or tone output is not
Cycle 2 used, CR input is connected to Vss.
2003.06.26
Silan
Semiconductors SC8560
PACKAGE OUTLINE
SDIP-28-400-1.778 UNIT:mm
SOP-28-375-1.27 UNIT:mm
Revision History