Nothing Special   »   [go: up one dir, main page]

Fire Combat Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

FIRE COMBAT

WE DEAL IN ALL TYPES OF FIRE FIGHTING EQUIPMENTS LIKE FIRE


EXTINGUISHER, FIRE HYDRANT AND SPRINKLER, FIRE ALARM AND
DETECTION SYSTEMS. WE GIVE OUTMOST IMPORTANCE TO QUALITY AND
SAFETY.

CONTACT US
302, PANDURANG NIWAS, VAKOLA BRIDGE
SANTACRUZ EAST 400055
PH- +91 8450966257
mail@firecombat.in

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
OUR PRODUCTS
ABC TYPE DRY POWDER

This is a premium range of appliances available in ABC and BC dry power,


pressurized with dry nitrogen gas. The contents are expelled by the release of
pressure stored inside the body. The inbuilt pressure gauge indicates its
readiness for use. ABC dry power is the most versatile and highly effective
agent suitable for areas where mixed hazards involved. The ABC type is filled
with monoammonium phosphate, a yellow powder.

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
CO2 GAS BASED TYPE FIRE EXTINGUSHERS

The quick & efficient flame knockdown property of CO2 gas makes it ideal for
tackling fire involving flammable liquid for oil, paints, varnish, solvents & even
industrial gases. Inert CO2 gas rapidly starves the fire of oxygen, extinguishing
within seconds. Since it leaves no residue after use, it is ideal for fire involving
sensitive electrical equipment. Carbon Di-Oxide Fire Extinguishing media is
highly effective against B & C Class of fire. The pressure is so great that it is not
uncommon for bits of dry ice to shoot out the nozzle. They don’t work very well
on class A fires because they may not be able to displace enough oxygen to put
the fire out, causing it to re-ignite. The Extinguisher is made from seamless
manganese cylinders approved by Chief Controller of Explosives (PESO), Nagpur

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
CLEAN AGENT TYPE FIRE EXTINGUSHER

There are three basic types of agents in Clean Agent fire extinguishers;
hydrofluorocarbon (HFC), hydrochlorofluorocarbon (HCFC), and
chlorofluorocarbon (CFC). These halogenated agents are electrically non-
conductive and non-corrosive. Clean Agent Fire Extinguishers is suitable for A
class, general paper, wood, cloth & B class inflammable liquids like kerosene,
paints, petrol etc & For C class of Fire gases in the compressed from, electrical
and electronic
Clean Agent Fire Extinguishers is Safe to use on all your sensitive equipment, the
Clean Agent Extinguisher brings you the added benefit of being the world’s most
advanced, and by far the most eco-friendly extinguisher. HFC 236FA the A
cleanest, most powerful Extinguisher agent on the planet.

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
K TYPE FIRE EXTINGUSHERS

Wet Chemical K-Class Fire Extinguishers are specifically designed to combat


restaurant kitchen fires. Class K fires most often occur where cooking media
(fats, greases, and oils) are used. These are most often found in commercial
cooking operations. Class K Extinguishers work on the principle of saponification.
Saponification takes place when alkaline mixtures such as potassium acetate,
potassium citrate, or potassium carbonate are applied to burning cooking oil of
fat. The alkaline mixture combined with the fatty acid creates a soapy foam layer
on the surface which holds in the vapors and steam and extinguishes the fire.
These agents are alkaline by nature and are the only extinguishing agents listed
for suppression of fires in commercial cooking because of their ability to
maintain the foamy layer enough to allow complete cooling. In addition, these
wet chemical agents pose minimal damage threat to hot appliances. Only the
class K fire extinguisher is compatible with the wet chemical agents. The use of
a multi-purpose ABC extinguisher threatens the foamy layer and cooling ability
of the wet chemical agent, and consequently can result in damage to cooking
appliances. Fire extinguishers are placed in relation to the hazards they are to
protect. Every commercial kitchen should have a Class K extinguisher located in
it to supplement the suppression system. It is best to use this extinguisher rather
than dry chemical alternatives.

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
AUTOMATIC MODULAR ABC TYPE FIRE EXTINGUISHER

Automatic Powder Fire Extinguisher mainly consist of MIG welded M.S. body 2
mm CRC Sheet upper part of which is fitted with adapter or Flange for fixing on
ceiling wall. And below part fixed automatic release Nozzle based on Sprinkler
technology unlike the Sprinkler Nozzle is gas tight the release temperature is
adjusted with sprinkler imported bulb set at 570 C, or 680 C or special
Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
temperatures according to specific requirements and imported pressure gauge
fitted for instant verification of reliability of every unit.
Nozzle is specially designed to give more that 99% discharge. Together with
orifice characteristic to cover adequately fire risks with scattering cone of 400
to 450 angle. There will always be areas in a workplace where the chances of
detecting a fire early are very few and human traffic, very low - factories with
large storage areas and server rooms, for instance. If a fire breaks out in such
areas, putting it out becomes almost impossible. Auto Safe is an Automatic
Extinguisher, which does not require any external source of power to operate.
It can be utilized for local applications or total flooding of hazards. The Modular
type Extinguisher is based on Sprinkler technology. Unlike the Sprinkler, the
Nozzle is Gas-tight. The release temperature can be adjusted to suit prevailing
conditions. This Extinguishers are most ideal for protection of computer area,
ATM Centre, server room, fuel and flammable liquid storage, oil fill-in stations,
transformers, automobile garages, marine engines, paint and varnish booths,
welding benches, domestic gas Storage’s particularly for hotels etc, and where
water damage cannot be tolerated. In the event of a fire, ceiling mounted
extinguishers activate automatically, spraying the extinguishing with maximum
force, ensuring that the fire is brought under control rapidly and efficiently. With
no piping or ducting required, these extinguishers can be rapidly installed with
no breakage, hassle or loss of man hours.

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
AUTOMATIC MODULAR HFC CLEAN AGENT TYPE FIRE EXTINGUISHER

Automatic HFC Clean Agent Fire Extinguisher mainly consist of MIG welded M.S.
body 2 mm CRC Sheet upper part of which is fitted with adapter or Flange for
fixing on ceiling wall. And below part fixed automatic release Nozzle based on
Sprinkler technology unlike the Sprinkler Nozzle is gas tight the release
temperature is adjusted with sprinkler imported bulb set at 570 C, or 680 C or
special temperatures according to specific requirements and imported pressure
gauge fitted for instant verification of reliability of every unit.
Nozzle is specially designed to give more that 99% discharge. Together with
orifice characteristic to cover adequately fire risks with scattering cone of 400
to 450 angle. There will always be areas in a workplace where the chances of
detecting a fire early are very few and human traffic, very low - factories with
large storage areas and server rooms, for instance. If a fire breaks out in such
areas, putting it out becomes almost impossible. Auto Safe is an Automatic
Extinguisher, which does not require any external source of power to operate.
It can be utilized for local applications or total flooding of hazards. The Modular
type Extinguisher is based on Sprinkler technology. Unlike the Sprinkler, the
Nozzle is Gas-tight. The release temperature can be adjusted to suit prevailing
conditions. This Extinguishers are most ideal for protection of computer area,
ATM Center, server room, fuel and flammable liquid storage, oil fill-in stations,

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
transformers, automobile garages, marine engines, paint and varnish booths,
welding benches, domestic gas Storage’s particularly for hotels etc, and where
water damage cannot be tolerated. In the event of a fire, ceiling mounted
extinguishers activate automatically, spraying the extinguishing with maximum
force, ensuring that the fire is brought under control rapidly and efficiently. With
no piping or ducting required, these extinguishers can be rapidly installed with
no breakage, hassle or loss of man hours.

2 WAY BREECHING DRY RISER INLET

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
 Technical Specifications: 2 Way Fire Brigade Inlet With, 2 Nos. Spring
loaded NRV And Rubber Cap With Chain.
 Size: 63mm
 Inlet: Male Inst. Inlet with built in NRV & 100mm NB flanged inlet.
 Material Body: Gun Metal & Stainless Steel
 NRV : Gun Metal & Stainless Steel
 Standard : IS: 904
 Body : Painted Fire Red Colour
 Male Adaptor : Polished
 Hydrostatic Test (Body Test): 21 Kgf/cm2
 Water tightness (Seat Test): 7 Kgf/cm2

4-WAY BREECHING DRY RISER INLET

 Technical Specifications: 4 Way Fire Brigade Inlet With, 4 Nos. Spring


loaded NRV And Rubber Cap With Chain.
 Size: 63mm
 Inlet: Male Inst. Inlet with built in NRV & 150mm NB flanged inlet.
 Material Body: Gun Metal & Stainless Steel
 NRV : Gun Metal & Stainless Steel
 Standard : IS: 904
 Body : Painted Fire Red Colour
 Male Adaptor : Polished
 Hydrostatic Test (Body Test): 21 Kgf/cm2
 Water tightness (Seat Test): 7 Kgf/cm2

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
WAY SUCTION COLLECTING INLET

 Technical Specifications: 3 Way Fire Brigade Inlet With, 3 Nos. Spring


loaded NRV And Rubber Cap With Chain.
Size: 63mm
 Inlet: Male Inst. Inlet with built in NRV & 100mm NB flanged inlet.
 Material Body: Gun Metal & Stainless Steel
 NRV : Gun Metal & Stainless Steel
 Standard : IS: 904
 Body : Painted Fire Red Colour
 Male Adaptor : Polished
 Hydrostatic Test (Body Test): 21 Kgf/cm2
 Water tightness (Seat Test): 7 Kgf/cm2

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
SINGLE / DOUBLE DOOR HOSE BOX

Thickness: 16 Gauge, 18 Gauge



 Size: 500 mm x 500 mm x 200 mm (SINGLE DOOR)
Size: 750 mm x 600 mm x 250 mm (DOUBLE DOOR)
 Material: Mild Steel Sheet, Stainless Steel Sheet, Aluminum Sheet & FRP
 Coating : P O Red Epoxy power coated
 For accommodating 1 nos of 15 meter hose and One Branch Pipe
(SINGLE DOOR)
For accommodating 2 nos of 15 meter hose and One Branch Pipe
(DOUBLE DOOR)
 Double Door type with Locking Arrangement, Front Glass and Key
 All sizes of Boxes / Frames fabricated as per customer specification

HOSE REEL DRUM

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
 Techanical Specification

 Type : Wall Mounted Fixed/Swinging Type


 Material of construction: M.S. Sheet 18 SWG and non-corrosive working
parts.
Size: Inlet : 1” Threaded inlet Connection
Outlet: 3/4” / 1” / 1-1/2’’ outlet connection For Hose to accommodate
30/ 36/ 40 Mtrs. Hoses
 Hose: Rubber Water Hose As per IS:12585, Typr-1,2 (Duly ISI Marked)
 Shut off Nozzles: ABS
 Conforming Specification : IS 884 / 1958
 Performance Test :
Hydrostatic Test : Tested at 21 Kgf/cm2
Range & Water Flow rate test at 7 Kgf/cm2
Discharge : 24LPM
Range (Jet Length) : 6mtr(min)

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
SINGLE HYDRANT LANDING VALVE

 Techanical Specification

 Inlet : 63mm
 Flange : 200mmx12mm thick
 Holes : 4nos x 19mm
 PCD : 160mm
 Material : Stainless steel / Gun Metal
 Hand Wheel : Grey Cast Iron
 Body : Paint Fire Red Colour
 Male Adaptor & Accessories : Polished
 Conforming Specification : IS 5290, Type-A, ISI Marked
 Performance Test :
 Hydrostatic Pressure Test : Tested at 21 kgF/cm2
 Water Tightness Test : Tested at 14 kgF/cm2
 Flow Test Per Minute: 900 Litter at 7 kgF/cm2

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
DOUBLE HYDRANT LANDING VALVE

 Techanical Specification

 Size : 63mm / 75mm / 80mm With Female Outlet


 Inlet : 75 mm
 Flange : 200mm x 12mm thick
 Holes : 8nos x 19mm
 PCD ::180mm
 Material : Stainless steel / Gun Metal
 Hand Wheel : Grey Cast Iron
 Body : Paint Fire Red Colour
 Male Adaptor & Accessories : Polished
 Conforming Specification : IS 5290, Type-A, ISI Marked
 Performance Test :
 Hydrostatic Pressure Test : Tested at 21 kgF/cm2
 Water Tightness Test : Tested at 14 kgF/cm2
 Flow Test Per Minute: : 1800 Litter at 7 kgF/cm2

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
BRANCH PIPE

 Techanical Specification

Size :63mm

 Sizes of Nozzles : 6mm, 12mm, 15mm, 20mm and 25mm
 Material : Stainless steel / Gun Metal
 Washer : IS 937 Type B
 Conforming Specification : IS 903, ISI Marked
 Performance Test :
 Hydrostatic (Body Test) : Tested at 21 Kgf/cm2
 Working Pressure : 7 Kgf/cm2
 Other Range : 52 mm and 38 mm

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
CANVAS HOSE PIPE

 Techanical Specification

 Hose : Reinforced Rubber Lined Fire Hose


 Conforming Specification : IS : 8423/1994, ISI Marked
 Application : This Reinforced Rubber Lined Fire Hose is used for water
delivery purpose in fire-fighting &
civil Engineering Fields etc.
 Jacket: Circular woven jacket made from a special cotton & synthetic
yarn with high abrasion and heat
resistance. Jacket is also treated with suitable rot proofing agent.
 Standard Length : 15 Mtrs & 30 Mtrs.

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
 End Connection : SS/GM Male Female couplling with GI/SS/Copper
binding
 FEATURES:
Compact, Flexible & Light weight, Low friction loss
Abrasion resistance Ability to withstand high operating & back pressure

FIRE EQUIPEMENT AMC

# FIRE AMC of high rise residential Building.

# Fire AMC of Office & Commercial Building

# Fire AMC of Industrial Buildings and warehouse

We do AMC of Pump House, Hydrant, Sprinklers, Fire Alarm and


other fire Systems as per IS codes. We follow complete IS standards
for AMC.

FIRE SYSTEMS DESIGN

We are also involved in Design of Fire Fighting Systems such as

# Fire Hydrant Systems


Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in
# Fire Sprinkler
# MVWS/HVWS
# Foam System
# Fire alarm & Smoke Detection System
# PA and Access Control

We design as per IS, TAC, NBC Part-4


with complete Auto cad, Design Basis Report (DBR) and Hydraulic
Calculations.

Contact Us
Fire Combat
302, Pandurang Niwas, Vakola Bridge
Santacruz East, Mumbai
400055
Call- +91 8450966257
Mail us – mail@firecombat.in

Fire Combat, 302, Pandurang Niwas, Vakola Bridge, Dattamandir Road, Santacruz East- 400055
Contact Us- +91 8450966257 E-mail- mail@firecombat.in www.firecombat.in

You might also like