Industrial Hydraulic Valves - EUROPE PDF
Industrial Hydraulic Valves - EUROPE PDF
Industrial Hydraulic Valves - EUROPE PDF
Series from A to Z
Series by function
Hydraulic Valves
Industrial Standard
Introduction
Product index, system solutions, Drive Controlled Pump, electro-hydraulic axes, explosion-proof valves 1
1
Directional Control Valves
Seated valves, spool valves, direct and pilot operated 2
Proportional DC Valves
Standard, high repeatability, VCD® performance 3
Pressure Valves
Subplate and screw-in mounting 4
Flow Valves
Throttle and flow control valves, subplate and screw-in mounting 5
Check Valves
Shuttle valves, direct and pilot operated check valves, subplate and screw-in mounting 6
Sandwich Valves
For pressure, check and flow functions 7
Slip-In Cartridge Valves
According to ISO 7368, with pressure, directional, flow and check functions 8
SAE Flange Valves
For pressure, directional, flow and check functions 9
Valves for Pipe Mounting
With pressure, directional, flow and check functions 10
Electronics
Amplifiers, axis controllers and accessories 11
Accessories
Subplates, pressure gauge valves, pressure switches, pressure intensifiers 12
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
Description Page
Chapter01.indd RH 17.04.2015
1 A
A10
Subplates for DC valves
Adaptor plate for regenerative and hybrid valves
12-7
12-34
D30FP
D31DW
DC valve, pilot operated, with EtherCAT
DC valve, pilot operated
3-118
2-61
A102 Subplate for pressure valves 12-11 D31NW DC valve, pilot operated 2-61
BK Bolt kit 12-38 D31NWR Regenerative and hybrid DC valve, pilot operated 2-74
C / 9C Check valves, direct operated 10-41 D3DL DC valve, direct operated, hand lever 2-100
C*A 2-way slip-in cartridge valve without auxiliary function 8-8 D3DP DC valve, direct operated, hydraulically 2-85
C*B 2-way slip-in cartridge valve with stroke limiter 8-9 D3DWR Regenerative and hybrid valve, direct operated 2-74
C*C 2-way slip-in cartridge valve for pilot system mounting 8-11 D3FB DC valve, direct operated, proportional, with / w/o OBE 3-14
C*F 2-way slip-in cartridge valve for pressure relief function 8-14 D3FB DC valve, direct operated, proportional, with CANopen 3-24
2-way slip-in cartridge valve D3FC DC valve, direct operated, proportional 3-65
C*G 8-15
for pressure relief function plus pilot system mounting D3FC DC valve, direct operated, proportional, with EtherCAT 3-83
C*H 2-way slip-in cartridge valve with stroke limiter 8-16 D3FP DC valve, direct operated 3-93
C*V 2-way slip-in cartridge valve with shuttle valve 8-19 D3FP DC valve, direct operated, with EtherCAT 3-118
C*W 2-way slip-in cartridge valve with shuttle valve 8-20 D3MW DC valve, direct operated 2-55
C10 D*C 2-way slip-in cartridge valve with position control 8-87 D3W DC valve, direct operated 2-39
C1DB 2-way slip-in cartridge valve, check valve 8-77 DC valve, direct operated,
D3W 2-46
C4V Check valve, direct operated 6-13 with inductive position control
C4V Check valve, pilot operated 6-18 D4L DC valve, direct operated, hand lever 2-100
C5P Check valve, pilot operated, SAE flange 9-64 D4P DC valve, direct operated, hydraulically 2-85
C5V Check valve, direct operated, SAE flange 9-60 D4S Seat valve, pipe mounting 10-24
CB Cartridge block 12-30 D4S Seat valve, subplate mounting 6-22
CE, CP 2-way slip-in cartridge valves without cover 8-4 D51* Cover plate 12-28
CM Check valve, direct operated 7-59 D5S Seat valve, SAE flange 9-33
Compax3F Electrohydraulic axis controller 11-22 D9L DC valve, direct operated 2-100
CP / 9CP Check valves, pilot operated 10-43 D9P DC valve, direct operated 2-85
CPOM Check valve, pilot operated 7-69 DSBA Pilot valve with preload valve 8-25
CPS Check valve, pilot operated 6-16 DSDU Pressure reducing valve, pilot operated, TÜV certificate 8-40
CS Check valve, direct operated 6-7 DUR*L06 Flow control valve, proportional, 2-way 5-20
CS06 Sandwich plate 12-26 EVSA Pressure reducing valve, direct operated 4-15
D*1FB DC valve, pilot operated, proportional, with/without OBE 3-34 EX-M05 Test unit 11-40
D*1FC DC valve, pilot operated, proportional 3-72 F / 9F Throttle check valves 10-37
D*1FC DC valve, pilot operated, proportional, with EtherCAT 3-83 F5C Throttle valve, proportional, SAE flange 9-47
D*1FP DC valve, pilot operated 3-107 FM Throttle check valve 7-47
D*1VW DC valve, pilot operated 2-61 FS Throttle check valve 5-6
D*1VWR Regenerative and hybrid valve, pilot operated 2-74 GFG2 Flow control valve, 2-way 5-10
D*1VWZ Regenerative and hybrid valve, pilot operated 2-74 H06 Sandwich plate 12-22
D11P DC valve, direct operated 2-85 H10 Sandwich plate for regenerative function 12-36
D1FB DC valve, direct operated, proportional, with CANopen 3-24 LCM Pressure compensator 7-40
D1FB DC valve, direct operated, proportional, with/without OBE 3-3 MSP Multi-station manifold 12-12
D1FC DC valve, direct operated, proportional 3-58 MV / 9MV Needle valves 10-33
D1FC DC valve, direct operated, proportional, with EtherCAT 3-83 MVI Check und throttle valve 5-2
D1FP DC valve, direct operated 3-86 N / 9N Needle valves 10-35
D1FP DC valve, direct operated, with EtherCAT 3-118 NS Needle valve 5-4
D1FV Pressure reducing valve, proportional, with/without OBE 3-50 PADA Adaptor plate 12-21
D1MW DC valve, direct operated 2-33 PC*MS Flow control valve, 2-way 5-8
D1SE Seat valve, 3/2-way 2-2 PCD00 E-module for proportional pressure flow control valves 11-10
D1VA DC valve, direct operated, pneumatically 2-96 PCM /
Flow control valves 10-39
D1VL DC valve, direct operated, hand lever 2-100 9PCM
D1VP DC valve, direct operated, hydraulically 2-85 PID00 Axis controller 11-18
D1VW DC valve, direct operated 2-5 PRDM Pressure reducing valve, direct operated 7-22
DC valve, direct operated, PRM Pressure reducing valve, pilot operated 7-27
D1VW 2-19
with inductive position control PRPM Pressure reducing valve, pilot operated, proportional 7-36
D1VW 8W DC valve, direct operated, 8 watt 2-13 PSB Pressure switch 12-42
D1VW Ex DC valve, direct operated, explosion proof 2-28
1 Cover for
pressure relief function
C*F
C*G
8-14
8-15
Pilot operated,
subplate mounting
VBY 4-10
D*FP
3-93
3-118
Shuttle valve
Sandwich plate
ZSRA /
ZSRB
8-28 1
subplate mounting 3/2-way, subplate mounting D1SE 2-2
Pilot operated, subpl. mounting D*1FP 3-107 Pipe mounting D4S 10-24
Directional seat valve
Pilot operated, with EtherCAT, Subplate mounting D4S 6-22
D*1FP 3-118
subplate mounting SAE flange D5S 9-33
Servo proportional Pilot operated, subpl. mounting D30FP 3-100 D11P 2-85
valve Pilot operated, with EtherCAT, D1VP 2-85
D30FP 3-118
subplate mounting Direct operated, hydraulically,
D3DP 2-85
Pilot operated, proportional, subplate mounting
TDP 8-113 D4P 2-85
2-way, cartridge
D9P 2-85
Pilot operated, proportional,
2-way, cartridge with shut-off TEP 8-124 Direct operated, solenoid, D1VW 8
2-13
valve 8 watt, subplate mounting Watt
Pilot operated, proportional, Direct operated, solenoid, ex-
TPQ 8-136 D1VW 2-28
3-way, cartridge plosion proof, subplate mounting
Direct operated, pipe mounting C / 9C 10-41 Direct operated, solenoid, D1VW 2-19
with inductive position control,
Direct operated, C4V 6-13 D3W 2-46
subplate mounting
subplate mounting CS 6-7
D1VW 2-5
Direct operated, SAE flange C5V 9-60
Direct operated, solenoid, D1MW 2-33
CM 7-59 subplate mounting
Direct operated, sandwich plate D3MW 2-55
ZRV 7-65
D3W 2-39
RK / RB 6-4
Direct operated, solenoid,
Block mounting SPV / SPZ 6-11 Z1DW 7-2
DC valve, direct sandwich plate
SPZBE 6-9 operated D1VL 2-100
Check valve Pilot operated, block mounting SVLB 8-79 D3DL 2-100
Direct operated, hand lever,
CP / 9CP 10-43 subplate mounting D4L 2-100
Pilot operated, pipe mounting
RH 10-45 D9L 2-100
C4V 6-18 Direct operated, pneumatically,
Pilot operated, D1VA 2-96
CPS 6-16 subplate mounting
subplate mounting
SVLA 8-28 Direct operated, proportional, D1FB 3-24
Pilot operated, SAE flange C5P 9-64 with CANopen,
subplate mounting D3FB 3-24
Pilot operated, sandwich plate CPOM 7-69
Direct/pilot operated, propor-
Pilot operated, sandwich plate,
ZRE 7-74 tional, with OBE and position
high performance D*FC 3-83
feedback, with EtherCAT,
D*1VWR 2-74 subplate mounting
Pilot operated,
Regenerative and D*1VWZ 2-74 Direct operated, proportional, D1FC 3-58
subplate mounting
hybrid DC valve D31NWR 2-74 with OBE and position feedback,
subplate mounting D3FC 3-65
Direct operated, subpl. mounting D3DWR 2-74
Multi-station manifold MSP 12-12 Direct operated, proportional, D1FB 3-3
with/without OBE,
Bolt kit BK 12-38 D3FB 3-14
subplate mounting
Pilot operated, high perfor-
Counterbalance valve ZNS 7-77 D*1VW 2-61
mance, sandwich plate Pilot operated,
D31DW 2-61
Tie rod kit TK 12-39 subplate mounting
D31NW 2-61
2-way, subplate mounting PC*MS 5-8
DC valve, Pilot operated, proportional, with
2-way, pipe mounting PCM / 9PCM 10-39
pilot operated OBE and position feedback, D*1FC 3-72
Flow control valve 2F1C 5-14 subplate mounting
2-way, subplate mounting
GFG2 5-10 Pilot operated, proportional,
Proportional, subplate mounting DUR*L06 5-20 with/without OBE, subplate D*1FB 3-34
With unloading function, UR06M / mounting
8-26
subplate mounting US06M CS06 12-26
With pressure relief function, RS06M 8-22 Sandwich plate H06 12-22
subplate mounting R06M 8-21 H10 12-36
With preload function,
DSBA 8-25
Pilot valve, subplate mounting
pressure function With sequence function,
S06M 8-27
subplate mounting
Proportional, with pressure relief
RPDM 8-23
function, sandwich plate
With pressure reducing function,
ZUDB 8-24
sandwich plate
When you entrust us with your system requirements, you In addition to customized solutions Parker also supplies
can rely on getting an optimal solution from the Parker standardized press controls (e.g. certified versions in
valves program with all components used in accordance nominal sizes NG06 up to NG50) as shown in our bro-
with their characteristics. Furthermore you can rely on us chure HY11-3235/UK "Hydraulics for Press Controls".
taking full responsibility for all our valves, electronics and Contact your Parker representation for information and
combined functions within the system. offerings concerning your hydraulics.
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
1 1. Pump
• Vane pump T7, catalogue HY29-0110, or
• Axial piston pump PVplus, catalogue HY30-3245, or
p (t), Q (t)
• Combination of vane pump and axial piston pump
• Mounting accessories for the motor pump assembly: pACT U
P
- Coupling Drive
- Pump bellhousing pCMD
Controlled
- Pump flange
QCMD Pump M P
2. Motor
• Asynchronous standard motor or AC30V (3)
nACT
Compax3S (C)
• Synchronous servo motor, catalogue 192-061011 and
192-061013
3. AC Drive Controller
• AC30V, catalogue 192-300022
• Compax3, catalogue 192-120013
4. Accessories that may be required 1)
• Shield connection
• Power cables
• Sensor cables
• Braking resistor
• Mains filters
• Pressure transducer
Parker DriveCreator
For optimum yet simple selection and dimensioning of
the components Parker offers a unique software tool:
the Parker DriveCreator. Firstly, the cycle data (pressure
and flow) is entered. Subsequently, the optimum pump
or combination of pumps is selected using this data, and
then motor and drive suitable for the power consumption.
The Parker DriveCreator calculates the best combina-
tion of components possible with the highest degree of
energy efficiency.
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
With the Parker electro-hydraulic linear drives, position The standard axes catalogue HY11-3341/UK contains
accuracy can be achieved reliably and cost-effectively in all information required to select and order a complete
all 3 performance classes: standard axis.
Chapter01.indd RH 17.04.2015
Technical features
• Stroke up to 3000 mm
1 • Push force up to 620 kN
• Pull force up to 320 kN
• Position and force control
• Speed up to 1 m/s
• Overload protection
• Integrated position feedback
• Long life time and low maintenance
• Only P and T need to be connected to the power supply
• 8 sizes (40/28 up to 200/140)
• Axis controller (option)
• Blocking valves (option)
• Pressure overload protection (option)
• Standard axis ordering code
Performance diagrams
In addition to the basic technical data the standard axes With individual diagrams for all cylinder and valve dimen-
catalogue provides easy to use information for the right sions the axes can easily be selected according to the
configuration. force and speed requirements.
Chapter01.indd RH 17.04.2015
Control Valves
For the 3 performance classes different valve series are ple closed loop solutions to highly sophisticated DFplus
used. Starting with standard proportional valves for sim- valves in performance class 3. 1
Controllers
Optionally the axes can be ordered with controller. In digital modules, in classes 2 and 3 the highly sophisti-
performance class 1 the axes are controlled by Parker cated Compax 3F controller is used.
Performance class 1: PWDXX digital module Performance classes 2 and 3: Compax3F axis controller
Chapter01.indd RH 17.04.2015
Directional control valve, series D1VW explosion Pilot operated directional control valve, series
proof D*W*EE explosion proof
The D1VW with explosion proof solenoids is the ATEX The D*1*W*EE with explosion proof solenoids is based
version of the standard D1VW series. It provides high on the standard D*1*W series. The pilot operated valves
functional limits up to 60l/min in combination with a very are available in 4 sizes from NG10 to NG32. All of them
low, energy-saving pressure drop. All explosion proof are piloted by a D1VW valve. All explosion proof solenoids
solenoids are DC design. The valves for AC operate with are DC design. The valves for AC operate with integrated
integrated rectifier. rectifier.
Further information about this valve can be found in
chapter 2.
Chapter01.indd RH 17.04.2015
Direct operated proportional DC valve, series Pilot operated proportional DC valve, series D*1FB*EE
D1FB*EE explosion proof explosion proof
The D1FB*EE series with explosion proof solenoids The D*1FB*EE series with explosion proof solenoids is 1
is the ATEX version of the standard D1FB series. The the ATEX certified version of the standard D*1FB series.
parameters can be saved, changed and duplicated in The valves work with barometric feedback of the main
combination with the digital power amplifier PWD00A-400 stage to the pressure reducing pilot valve. The parameters
(to be used in an explosion proof cabinet or outside of can be saved, changed and duplicated in combination with
the hazardous area). the digital power amplifier PWD00A-400 (to be used in an
explosion proof cabinet or outside of the hazardous area).
Features
• Spool/sleeve and spool/body Features
• High repeatability from valve to valve • Progressive flow characteristics for sensitive adjust-
ment of flow rate
• Low hysteresis
• High flow capacity
• Manual override
• 4 sizes, NG10 to NG32
A B A B
a 0 b a 0 b
P T
P T
Proportional pressure reducing valve, series Direct operated prop. pressure valve, series
D1FV*EE explosion proof RE06M*W*EE explosion proof
The D1FV*EE series with explosion proof solenoids is ATEX certified pressure relief valves of the series
based on the standard D1FV series. In combination with RE06M*W*EE are direct operated proportional valves
the digital power amplifier PWD00A-400 (to be used in an typically used as remote control valves for flow rates
explosion proof cabinet or outside of the hazardous area), below 3 l/min. The optimum performance can be
the parameters can be saved, changed and duplicated. achieved in combination with the digital amplifier module
The D1FV values control the pressure in the A- or B-ports PCD00A-400 (to be used in an explosion proof cabinet
using the barometric feedback principle. or outside of the hazardous area).
Features Features
• Barometric feedback • Direct operated with proportional solenoid
• High repeatability from valve to valve • Very low pressure adjustment of pmin
• Low hysteresis • 2 pressure ports, A and P (1 pressure port for XG087)
• Manual override • Subplate mounting according to ISO 6264
• 3 pressure stages
T P P T
a b
B A
P B A T
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
Chapter01.indd RH 17.04.2015
D1VW
Spool valves, electrically operated
Standard, soft shift • 2-5
2
D1VW 8 Watt solenoid • 2-13
D1VW Inductive position control • 2-19
D1VW Explosion proof (conform to ATEX and IECEx) • 2-28
D1MW For wash down applications • 2-33
D3W Standard • 2-39
D3W Inductive position control • 2-46
D3MW For wash down applications • 2-55
D31DW Standard and position control • 2-61
D31NW Highest flow •
D41VW Standard and inductive position control •
D81/91VW Standard and inductive position control •
D111VW Standard and inductive position control •
Spool valves, electrically operated, regenerative and hybrid design
D3DWR Hybrid configuration with sandwich plate • 2-74
D31NWR Hybrid configuration with sandwich plate •
D41VWR/Z •
D91VWR/Z •
D111VWR/Z •
Spool valves, hydraulically operated
D1VP • 2-85
D3DP •
D4P •
D9P •
D11P •
Spool valves, pneumatically operated
D1VA • 2-96
Spool valves, mechanically operated
D1VL • 2-100
D3DL •
D4L •
D9L •
Accessories
Plugs 2-111
Actuator kits 2-112
O-rings and seal kits 2-113
Slip-in orifices 2-114
Mounting patterns 2-115
Content02.indd RH 17.04.2015
Ordering code
D 1 S E B W
Directional Size Seat Wet pin Spool Style Seals Solenoid Connector Design
control DIN NG06 valve armature type voltage as per series
valve CETOP 03 solenoid, EN 175301-803 (not required
for ordering)
NPPA D03 flanged without plug 1)
83
Code Seals
N NBR
V FPM
power supply.
General
Design Directional poppet valve
Actuation Solenoid
Size DIN NG6 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
2
Mounting position Unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60, observe permissible duty cycle
MTTFD value [years] 150
Weight [kg] 1.5
Hydraulic
Max. operating pressure [bar] P, A, T: 350
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+60 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 10...500
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 20
Static / Dynamic
Step response [ms] Energized: approx. 50
[ms] De-energized: approx. 60
Electrical characteristics
Duty ratio See diagram
Max. switching frequency [1/h] 2000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 1.95 1.1 0.25 0.13
Power consumption [W] 23.4 26.4 24.3 26.6
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
A B
Technical data
General
Design Directional spool valve
Actuation Solenoid
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Weight [kg] 1.5 (1 solenoid), 2.1 (2 solenoids)
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A, B: 350; T: 210 (DC), T: 140 (AC)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 80 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool, up to 15 per flow path for spool type 008 + 009
Static / Dynamic
Step response see table response time
Electrical characteristics
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000 (not for soft shift)
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G Y T
110 V at 50 Hz/ 230 V at 50 Hz/
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
120 V at 60 Hz 240 V at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
Current consumption in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold 32.7 W 31 W 31.9 W 28.2 W 70 / 70 VA 70 / 70 VA
Power consumption in rush 32.7 W 31 W 31.9 W 28.2 W 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W).
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D 1 V W
Directional Size 3-chamber Wet pin Spool Spool
control DIN NG06 valve armature type position
valve CETOP 03 solenoid,
2
NFPA D03 threaded
in tube
3 position spools
Code Spool type
a 0 b
001
002
3 position spools
003
Code Spool position
004 3 positions.
005 C Spring offset in position “0“.
Operated in position “a“ or “b“.
006 Spool type
Standard
007 008,009, 204, 205
008 1)
2 positions.
009 1) E
Spring offset in position “0“.
Operated in Operated in
010 position “a“. position “b“.
011
014 2 positions.
F
Operated in position “0“.
Spring offset in Spring offset in
015
position “b“. position “a“.
016
021 2 positions.
K
Spring offset in position “0“.
022 Operated in Operated in
position “b“. position “a“.
031
032
2 positions.
M
034 Operated in position “0“.
Spring offset in Spring offset in
035 position “a“. position “b“.
W
Seals Solenoid Solenoid Solenoid Design
voltage connector as per option series
EN 175301-803, (not required
2
without plug for ordering)
(other connectors
are available for
D1MW Series)
Code Solenoid option
omit manual override (standard)
T without manual override
S2 3) Soft shift orifice size 0.5 mm.
S3 3) Soft shift orifice size 0.75 mm.
4N 3) with lockable manual override
Code Voltage
K 12 V =
J 24 V =
U 2) 98 V =
G 2) 205 V =
110 V 50 Hz /
Y 120 V 60 Hz
230 V 50 Hz /
T 240 V 60 Hz
Code Seals
N NBR
V FPM
Flow curve
14 13 10 9 8
24
7
20 6
2 16
5
11 3
12 2
1
12
8
Pressure drop [bar]
0
0 20 40 60 80
Flow [l/min]
101B 11 10 10 9
102 1 4 1 4 5 5 8 8 6
61 1 3 1 3 3 2
83H 5 2 5 2
208 3 2
P-B A-T P-A B-T P-A P-B A-T B-T P-T
008 4 5 4 5 9
009 5 5 6 7 7
83B 5 2 5 2
204 1 3 4 3 7 4 7
205 4 3 1 3 7 4 5
1)
Only for pressure compensation, no high flow possible.
The diagram below specifies the shift limits for valves anced flow conditions. The shift limits can be considerably
with DC & AC solenoids. Valves with spool position “F” lower at unbalanced flow conditions. To avoid flow rates
or “M” can only be operated up to 70 % of the limits. The beyond the shift limits, a plug-in orifice can be inserted
specifications apply to a viscosity of 40 mm2/s and bal- in the P-port.
50
0
0 10 20 30 40 50 60 70 80 90
Flow [l/min]
350
Pressure [bar]
101 009,
300 011,
102 010,021,
250 022
003, 015,
204, 205
200
082
150
100
50
0
0 10 20 30 40 50 60 70 80 90
Flow [l/min]
2 150
100
50
0 10 20 30 40 50 60 70 80
Flow [l/min]
250
200
150
100
50
0 10 20 30 40 50 60 70 80
Flow [l/min]
Measured with HLP46 at 50 °C, 90 % Unom and warm solenoids.
Acceleration for orifice size 0.75, code “S3” (measured against a standard valve)
build-in
orifice
A B
For even softer shifting, the proportional spools 081, 082, 101 and 102 can be used.
Ø9.5 Ø9.5
93
93
2
69
69
22
22
A B A B
Ø5.5 Ø5.5
91.4 134.6
162 46 162 46
Ø9.5 Ø9.5
93
93
69
22
22
A B A B
Ø5.5 Ø5.5
91.4 119.4
226 46 190
Ø9.5 Ø9.5
93.5
93.5
69.5
69.5
22
22
A B A B
Ø5.5 Ø5.5
84 127
152 46 152 46
C, D -style
Ø9.5
93.5
69.5
22
A B
Ø5.5
84
211 46
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
A B
Technical data
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Weight [kg] 1.5 (1 solenoid), 2.1 (2 solenoids)
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A B: 350, T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 60 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 80...120; De-energized: 35...55
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 70 °C possible
Max. switching frequency [1/h] 10000
Protection class IP65 in acc. with EN 60529, M12x1 IP67 (each with correctly mounted plug-in connector)
Code J
Supply voltage [V] 24 V =
Tolerance supply voltage [%] ±10
Current consumption [A] 0.33
Power consumption [W] 8
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W).
Plug M12x1 on coil as per IEC 61076-2-101 (code D).
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D 1 V W
Directional Size 3-chamber Wet pin Spool Spool
control DIN NG06 valve solenoid type position
valve CETOP 03
2
NFPA D03
3 position spools
Code Spool type
a 0 b
001
3 position spools
002
Code Spool position
003 3 positions.
C Spring offset in position “0“.
004 Operated in position “a“ or “b“.
005 Spool type
Standard
008, 009
006
007 2 positions.
E
Spring offset in position “0“.
008 1) Operated in Operated in
position “a“. position “b“.
009 1)
010 2 positions.
K
Spring offset in position “0“.
011 Operated in Operated in
position “b“. position “a“.
014
020
026
030
101
J L
Seals Solenoid Connection 8 watt Electrical Acces- Design
voltage Solenoid option sories series
24 V= (not required
2
for ordering)
Code Accessories
Standard valve (in combina-
omit tion with solenoid connec-
tion “D“ and “W“)
Only in combination with sole-
5 noid connection “D“ and surge
diode with LED “J“
Solenoid identification
acc. to ISO 9461
Code Connection
M12x1 on coil as per
D 3)
IEC 61076-2-101
Connector as
W 3) per EN 175301-803,
without plug
Code Seals
N NBR
V FPM
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
2
Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T
001 3 3 3 3 – – – – –
002 3 4 3 4 1 1 3 3 1
003 4 4 4 5 – – 4 – –
004 3 4 3 4 – – 4 4 –
005 3 3 3 3 8 (max. 30l) – – – –
006 3 4 3 4 4 4 – – –
007 4 3 3 3 – 2 – 1 4
010 4 – 4 – – – – – –
011 3 3 3 3 – – 11 (max. 25l) 11 (max. 25l) –
014 4 3 3 3 2 – 1 – 4
015 4 5 4 4 – – – 4 –
016 3 3 3 3 – 8 (max. 30l) – – –
020B 4 4 3 4 – – – – –
026B 4 – 4 – – – – – –
030B 3 4 4 3 – – – – –
081 9 10 9 10 – – – – –
082 9 10 9 10 – – – – –
101B 4 (max. 40l) 7 7 6 – – – – –
102 3 4 3 4 3 3 5 5 3
P->B A->T P->A B->T P->A P->B A->T B->T P->T
008 4 5 4 5 – – – – 6
009 5 5 5 5 – – – – 4
11 10 9
24 7
20 6
16
5
14
4
3
12
8
Pressure drop [bar]
2
8 1
0
0 10 20 30 40 50 60
Flow [l/min]
The diagram below specifies the shift limits. The specifica- unbalanced flow conditions. To avoid flow rates beyond
tions apply to a viscosity of 40 mm2/s and balanced flow the shift limits, a plug-in orifice can be inserted in the
conditions. The shift limits can be considerably lower at P-port.
Shift limits
350
001,
2
082,
300 101 010, 006
102
020
250 009,
081
200
Supply pressure [bar]
150
100
50 008,
026
0
0 10 20 30 40 50 60
Flow [l/min]
350
002, 004,
003, 011,
300 007, 005,
015, 030
014 016
250
200
Supply pressure [bar]
150
100
50
0
0 10 20 30 40 50 60
Flow [l/min]
M12 pin assignment DESINA design (code „JDLJ5“), M12 pin assignment code “JDL“,
Pins 1 and 2 connected Pins 1 and 2 not connected
A B
Ø9.5 Ø9.5
93
93
69
69
22
22
A B A B
87.3 Ø5.5 Ø5.5 130.7
156 46 156 46
Style C, D
A B
Ø9.5
93
69
22
A B
87.3 Ø5.5
218 46
Ø9.5 Ø9.5
98
98
71
71
22
22
A B A B
87.3 Ø5.5 Ø5.5 130.7
156 46 156 46
Style C, D
Ø9.5
98
71
22
A B
87.3 Ø5.5
218 46
Surface finish
Attention:
The adjustment of the position control is factory set
and sealed. Replacement and repairs can only be
undertaken by the manufacturer.
D1VW*B D1VW*C
D1VW*B
A B
D1VW*C
D 1 V W
Directional Size 3-chamber Wet pin Spool Spool
control DIN NG06 valve solenoid type position
valve CETOP 03
2
NFPA D03
3 position spools
Code Spool type
a 0 b
001
002
005 2 positions.
E
Spring offset in position “0“.
015 2)
076 2 positions.
F
Operated in position “0“.
078 Spring offset in position “b“.
2 position spools
2 positions.
Code Spool type K
a b Spring offset in position “0“.
Operated in position “b“.
020
0263) 2 positions.
M
0303) Operated in position “0“.
Spring offset in position “a“.
2 position spools
Code Spool position
2 positions.
B Spring offset in position “b“.
Operated in position “a“.
2 positions.
H Spring offset in position “a“.
Operated in position “b“.
1)
Only available for spool position “E“ and “F“.
2)
Only available for spool position “K“ and “M“.
3)
Only available for spool position “B“ and “H“.
4)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
5)
Please order female connector M12x1 separately (see accessories, female connector M12x1 (order no.: 5004109).
6)
For hydraulic presses according to the safety regulations EN 693, solenoid option “T” (without manual override) and accessory “I4N” or “I5N” (start position moni-
tored) are required.
W
Seals Solenoid Connector Manual Position Design
voltage as per EN override control 5) series
175301-803, option (not required
2
without plug for ordering)
(please order
plug separately)
Code Voltage
K 12 V=
J 24 V=
U4) 98 V=
G4) 205 V=
Code Seals
N NBR
V FPM
D 1 V W W
Directional Size 3-chamber Wet pin Spool Spool Seals Solenoid Connector Manual Position Design
control DIN NG06 valve solenoid type position voltage as per EN override control 5) series
valve CETOP 03 175301-803, option (not required
2
NFPA D03 without plug for ordering)
(please order
plug separately)
002
003 1)
Code Manual override
004 manual override
omit
(Standard)
015 1)
without manual
T4)
override
2 position spools
Code Spool type
a b
020
Code Voltage
K 12 V=
J 24 V=
3 position spools
U3) 98 V=
Code Spool position
G3) 205 V=
3 positions.
C Spring offset in position “0“.
Operated in position “a“ or “b“.
Code Seals
2 position spools
N NBR
Code Spool position
V FPM
2 positions.
D 2) Operated in position “a“ or “b“.
No center or offset position.
1)
Only for position control code “I6N“.
2)
Only for position control code “I3N“.
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4)
For hydraulic presses according to the safety regulations EN 693, solenoid option “T” (without manual override) and accessory “I6N” (start positions) is required.
5)
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
2
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.8 (1 solenoid) / 3.8 (2 solenoids)
Hydraulic
Max. operating pressure [bar] P, A B: 350 ; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 80 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 32 ; De-energized: 40
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
2 Polarity protection
Current consumption without load
[V]
[mA]
300
≤20
Switching hysteresis [mm] <0.06
Max. output current per channel, ohmic [mA] 250
Ambient temperature [°C]-20 … +60
Protection IP65 acc. EN 60529 (with correctly mounted plug-in connector)
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
CE conform EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6 1) / ENV 50140 / ENV 50204
1)
Only guaranted with screened cable and female connector
1
US
DC st
1 + US 19.2...28.8 V 4
2 1 DC
AC
2 Out B: normally open OSZ. DC
Out
3 0V 2
3 4 Out neg.
4 Out A: normally closed
3
GND
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the spring is reached (above 85 % spool stroke).
offset position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
The switch can only be located on the opposite side of the solenoid for direct operated valves.
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
1 Us 10...30 V
2 not connected
3 0V
4 Out A: normally open
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the center is reached (above 85 % spool stroke).
position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
001,002
300
200
026
150
100
50
0
0 10 20 30 40 50 60 70 80 90
Flow [l/min]
All characteristic curves measured with HLP46 at 50 °C, 90 % Unom and warm solenoids.
93
2
69
Ø42
22
A B
91.5 Ø5.5
242 46
271.5
H, K, M -style
No defined position
for female connector Ø9.5
93
69
Ø42
22
A B
Ø5.5
134.5
242 46
271.5
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
The space necessary to remove the M12x1 female connector is at least 22 mm.
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be un-
dertaken by the manufacturer.
1)
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
2)
Please order plug M12x1 separately. Straight plug recommended – no defined position possible for angled plug.
2 Ex e mb II T4 Gb
for use in zone 1 and 2 (according to ATEX). Additionally
the solenoids are IECEx compliant.
All explosion proof solenoids are DC design. The valves
for AC operate with integrated rectifier.
For further explosion proof valves please refer to cata-
logue HY11-3343.
Download: www.parker.com/euro_hcd - see “Literature”
A B
Technical data
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20 ... +60
MTTFD [years] 150
Weight [kg] 1.8 (1 solenoid), 2.7 (2 solenoids)
Hydraulic
P, A B: 350
Max. operating pressure [bar]
T: 140
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +60
Viscosity permitted [cSt] / [mm²/s] 2.8 ... 400
Viscosity recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 60 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Energized: 32 (DC), 40 (AC)
Step response at 95 % [ms]
De-energized: 40 (DC), 75 (AC)
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 135 °C possible
Max. switching frequency [1/h] 15000 (DC), 7200 (AC)
Protection class , Ex e mb II T4 Gb, IP66 (plugged and mounted correctly)
Code J N P
Supply voltage / ripple [V] 24 V = 230/50 Hz 110/50 Hz
Tolerance supply voltage [%] ±10 ±10 ±10
Current consumption [A] 1.0 0.12 0.25
Power consumption [W] 24 24 24
Solenoid connection Box with M20x1.5 entry for cable glands. Solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D 1 V W E E
Directional Size 3-chamber Wet pin Spool Spool Seals Solenoid Connection: Solenoid Design
control DIN NG06 valve solenoid type position voltage Explosion options: series
valve CETOP 03 proof Explosion (not required
2
NFPA D03 with cable proof for ordering)
glands Ex e mb II
and IECEx
conformity
3 position spools Code Voltage
Code Spool type
J 24 V=
a 0 b
P 110 V 50 Hz
001
N 230 V 50 Hz
002
003
Code Seals
004
N NBR
005 V FPM
006
007
3 position spools
008 1)
Code Spool position
009 1) 3 positions.
C Spring offset in position “0“.
010
Operated in position “a“ or “b“.
011 Spool type
Standard
008, 009
014
015 2 positions.
E
Spring offset in position “0“.
016 Operated in Operated in
position “a“. position “b“.
021
022 2 positions.
K
081 Spring offset in position “0“.
Operated in Operated in
position “b“. position “a“.
082
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
2 002
003
1
3
4
4
1
3
4
6
1 1 5
7
5 2
004 2 3 2 3 7 7
005 2 2 2 2 12
006 1 4 1 4 7 7
007 3 2 2 2 3 2 7
010 3 3
011 2 2 2 2 14 14
014 3 2 2 2 3 2 7
015 3 6 3 4 7
016 2 2 2 2 12
020B 4 4 2 3
026B 4 4
030B 2 3 1 2
081 13 13 13 13
1) 1)
082 13 13 13 13
101B 11 10 10 9
102 1 4 1 4 5 5 8 8 6
P-B A-T P-A B-T P-A P-B A-T B-T P-T
008 4 5 4 5 9
009 5 5 6 7 7
The diagram below specifies the shift limits for valves shift limits can be considerably lower at unbalanced flow
with AC and DC solenoids. The specifications apply to a conditions. To avoid flow rates beyond the shift limits, a
viscosity of 40 mm2/s and balanced flow conditions. The plug-in orifice can be inserted in the P-port.
2
Shift limit diagram with DC solenoid
Dimensions
B, E -style H, K -style
C, D -style
Surface finish
NBR
4x M5x30 7.6 Nm NBR: SK-D1VW-N-91
BK375
ISO 4762-12.9 ±15 % FPM: SK-D1VW-V-91
D 1 M W
Directional Size 3-chamber Wet pin Spool Spool
control DIN NG06 valve for armature type position
valve CETOP 03 mobile and solenoid,
2
NFPA D03 marine threaded
applications in tube
3 position spools
Code Spool type
a 0 b
001
2 positions.
M
Operated in position “0“.
Spring offset in Spring offset in
position “a“. position “b“.
2 position spools
Code Spool position
2 positions.
B Spring offset in position “b“.
Operated in position “a“.
2 positions.
D Operated in position “a“ or “b“.
No center or offset position.
2 positions.
H Spring offset in position “a“.
Operated in position “b“.
1)
Consider specific spool position.
2)
Please order plug separately.
3)
Only in combination with connection “J” and “W”.
2
for ordering)
Code Connection
Connector as
W 2)
per EN 175301-803
Connector
J 2)
DT04-2P “Deutsch“
2-pin AMP
A 2)
Junior Timer
Code Seals
N NBR
V FPM
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
2 002
004
1
2
4
3
1
2
4
3
1
–
1
–
5
7
5
7
2
–
006 1 4 1 4 7 7 – – –
011 2 2 2 2 – – 10 10 –
020B 4 4 2 3 – – – – –
030B 2 3 1 2 – – – – –
081 9 9 9 9 – – – – –
082 9 9 9 9 – – 1) 1)
–
P->B A->T P->A B->T P->A P->B A->T B->T P->T
008 4 5 4 5 – – 8
Position „b“ Position „a“
P ->A P->B A->B P->B A->T
021 2 4 – 4 2 –
P ->A B->T P ->A P->B A->B
022 6 2 5 2 –
20 6
5
16 4
3
12 2
1
8
0
0 10 20 30 40 50 60 70 80
Flow [l/min]
All characteristic curves measured with HLP46 at 50 °C.
Shift limits
350 The diagram specifies the shift limits.
011 001, 002, 006
300 Valves with spool position “F” or “M”
020, 030 can only be operated up to 70 % of
081 004
250 the limits. The specifications apply to
082 a viscosity of 40 mm2/s and balanced
Supply pressure [bar]
021, 022
200 flow conditions. The shift limits can be
150 considerably lower at unbalanced flow
conditions. To avoid flow rates beyond
100 008 the shift limits, a plug-in orifice can be
inserted in the P port.
50
0
0 10 20 30 40 50 60 70 80 90
Flow [l/min]
Measured with HLP46 at 50 °C, 90 % Unom and warm solenoids.
1)
Only for pressure compensation, no higher flow possible.
Ø9.5 Ø9.5
93
93
69
69
22
22
A B A B
Ø5.5 Ø5.5
91.4 134.6
162 46 162 46
176 (manual override 176 (manual override
with rubber cover) with rubber cover)
C and D -style
Ø9.5
93
69
22
A B
Ø5.5
91.4
226 46
254 (manual override
with rubber cover)
Dimensions with 2pin AMP Junior Timer Connector (only C and D -style shown)
Ø9.5
67
22
A B
Ø5.5
91.4
226 46
254 (manual override
with rubber cover)
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
A B
Technical data
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Weight [kg] 4.8 (1 solenoid), 6.3 (2 solenoids)
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 210 (DC), 105 (AC)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 (DC); 115 (AC) (see shift limits)
Leakage at 50 bar [ml/min] Up to 20 per flow path, depending on spool
Static / Dynamic
Step response see table response times
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G Y T
110 V at 50 Hz/ 230 V at 50 Hz/
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V =
120 V at 60 Hz 240 V at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 3 1.5 0.35 0.18 0.8 / 0.72 0.4 / 0.36
Current consumption in rush [A] 3 1.5 0.35 0.18 3.41 / 3.31 1.75 / 1.7
Power consumption hold [W] 36 36 34 36 88 / 86 88 / 86
Power consumption in rush [W] 36 36 34 36 375 / 397 385 / 408
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D 3 W
Directional Size Wet pin Spool Spool
control DIN NG10 solenoid type position
valve CETOP 05
2
NFPA D05
3 position spools
Code Spool type
a 0 b
001
007 2 positions.
E
008 1) Spring offset in position “0“.
Operated in Operated in
position “a“. position “b“.
009 1)
010 2)
2 positions.
F
011 Operated in position “0“.
Spring offset in Spring offset in
position “b“. position “a“.
012
014
2 positions.
K
015 Spring offset in position “0“.
Operated in Operated in
position “b“. position “a“.
016
021 2)
2 positions.
M
022 2) Operated in position “0“.
Spring offset in Spring offset in
position “a“. position “b“.
031 2)
2 positions.
082 2) B Spring offset in position “b“.
Operated in position “a“.
102 2)
2 positions.
D Operated in position “a“ or “b“.
2 position spools No center or offset position.
Code Spool type
a b 2 positions.
H Spring offset in position “a“.
020 Operated in position “b“.
026
030
101 2)
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4)
DC only.
W
Seals Solenoid Connector Solenoid Shift Design
voltage as per option response series
EN 175301-803, (not required
2
without plug for ordering)
(Please order plug
separately)
Code Shift response
omit Standard response
orifice diameter
S4 4)
1.0 mm
orifice diameter
S7 4)
1.75 mm
Code Seals
N NBR
V FPM
The flow curve diagram shows the flow versus pressure operating position and flow direction the relevant curve
drop curves for all spool types. For each spool type, number is given in the table below.
2
001 6 5 6 6 – – – – – –
002 3 5 3 3 1 1 4 5 1 6
003 2 2 3 1 – – 3 – – –
004 5 4 4 4 – – 8 8 – 9
005 2 2 2 2 3 – – – – –
006 1 2 1 3 2 2 – – – 3
007 2 1 2 2 – 1 – 2 3 –
010 2 – 2 – – – – – – –
011 2 2 2 2 – – 11 11 – 11
012 1 2 2 2 10 10 10 10 11 11
014 1 2 2 2 1 – 2 – 3 –
015 2 1 2 2 – – – 3 – –
016 2 2 1 2 – 2 – – – –
020 6 6 5 7 – – – – – –
026 5 – 5 – – – – – – –
030 4 5 3 5 – – – – – –
P->B A->T P->A B->T P->A P->B A->T B->T P->T A->B
008 8 7 7 6 – – – – 9 –
009 4 4 5 8 – – – – 9 –
Position b Position a
P->A P->B A->B P->B A->T
021 2 4 8 3 2
P->A B->T P->A P->B A->B
022 3 2 3 2 8
18
7
16
6
14
5
12
4
10
3
8
2
6
1
4
2
0
0 50 100 150
Flow [l/min]
The diagrams below specify the shift limits for valves with anced flow conditions. The shift limits can be considerably
DC and AC solenoids. Valves with spool position “F” or lower at unbalanced flow conditions. To avoid flow rates
“M” can only be operated up to 70 % of the limits. The beyond the shift limits, a plug-in orifice can be inserted
specifications apply to a viscosity of 40 mm2/s and bal- in the P-port.
Shift limits, DC voltage
2
Acceleration for different orifice sizes (archived against a valve without soft shift)
Orifice in anchor
A B
For even softer shifting, the proportional spools 081, 082, 101 and 102
can be used.
C, D -style
C, D -style
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Attention:
The adjustment of the position control is factory set
and sealed. Replacement and repairs can only be
undertaken by the manufacturer.
D3W*B D3W*C
D3W*B
A B
D3W*C
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
2
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 5.2
Hydraulic
Max. operating pressure [bar] P, A, B: 350; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 (see shift limits)
Leakage at 50 bar [ml/min] Up to 20 per flow path, depending on spool
Static / Dynamic
Step response at 95 % Energized: 105; de-energized: 85
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption hold [A] 3 1.5 0.35 0.18
Power consumption hold [W] 36 36 34 36
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D 3 W
Directional Size Wet pin Spool Spool
control DIN NG10 solenoid type position
valve CETOP 05
2
NFPA D05
3 position spools
Code Spool type
a 0 b
001
002
3 position spools
003 1)
Code Spool position
004
2 positions.
005 2) E Spring offset in position “0“.
Operated in position “a“.
015 2)
2 positions.
016 1) F Spring offset in position “b“.
Operated in position “0“.
021 1)
2 positions.
022 2) K Spring offset in position “0“.
Operated in position “b“.
2 position spools
Code Spool type 2 positions.
a b M Spring offset in position “a“.
020 Operated in position “0“.
2 positions.
H Spring offset in position “a“.
Operated in position “b“.
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4)
Please order female connector M12x1 separately (see accessories, female connector M12x1 (order no.: 5004109).
5)
For hydraulic presses according to the safety regulations EN 693, solenoid option “T” (without manual override) and accessories “I4” or “I5” (start position monitored)
are required.
W N
Seals Solenoid Connector Manual Position Inductive Design
voltage as per override control 4) position series
EN 175301-803, option control with (not required
2
without plug CE-code for ordering)
(Please order plug
separately)
Code Position control Spool position
End position
I2 E, F, B
monitored side B
(Solenoid
Start position on a-side)
I5 5)
monitored side B
End position
I1 K, M, H
monitored side A
(Solenoid
Start position on b-side)
I4 5)
monitored side A
Code Seals
N NBR
V FPM
D 3 W W N
Directional Size Wet pin Spool Spool Seals Solenoid Connector Manual Position Inductive Design
control DIN NG10 solenoid type position voltage as per override control 3) position series
valve CETOP 05 EN 175301-803, option control with (not required
2
NFPA D05 without plug CE-code for ordering)
(Please order plug
separately)
002
004
Code Solenoid option
manual override
2 position spools omit
(Standard)
Code Spool type
a b without manual
T 4)
override
020 1)
026 1)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
2)
3)
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.
4)
For hydraulic presses according to the safety regulations EN 693, solenoid option “T” (without manual override) and accessory “I6” (start positions) is required.
1 + US 19.2...28.8 V
2 1
2 Out B: normally open
3 0V
3 4
4 Out A: normally closed
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the spring is reached (above 85 % spool stroke).
offset position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
The switch can only be located on the opposite side of the solenoid for direct operated valves.
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] 0...+50
Supply voltage Us / ripple [V] 10...30 / ±10 %
2 Current consumption without load
Max. output current per channel, ohmic
[mA]
[mA]
≤ 10
200
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V] ≤2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1 acc. to IEC 61076-2-101
Wiring min. [mm²] 3 x 0.14 brad shield recommended
Wiring length max. [m] 50 recommended
1 Us 10...30 V
2 not connected
3 0V
4 Out A: normally open
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the center is reached (above 85 % spool stroke).
position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
Position b Position a Position 0
Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T A->B
001 6 5 6 6 – – – – – –
2
002 3 5 3 3 1 1 4 5 1 6
003 2 2 3 1 – – 3 – –
004 5 4 4 4 – – 8 8 – 9
005 2 2 2 2 3 – – – – –
015 2 1 2 2 – – – 3 – –
016 2 2 1 2 – 2 – – – –
020 6 6 5 7 – – – – – –
026 5 – 5 – – – – – – –
030 4 5 3 5 – – – – – –
Position b Position a
P->A P->B A->B P->B A->T
021 2 4 8 3 2
P->A B->T P->A P->B A->B
022 3 2 3 2 8
18
7
16
6
14
5
12
4
10
3
8
2
6
1
4
2
0
0 50 100 150
Flow [l/min]
All characteristic curves measured with HLP46 at 50 °C.
150
100
50 004 026
0
0 50 100 150
Flow [l/min]
Measured with HLP46 at 50 °C, 90 % Unom and warm solenoids.
114
Ø42
30
A B
Ø6.8
124
292.5 70
322
H, K, M -style
No defined position Ø11
for female connector
114
Ø42
30
A B
Ø6.8
178
292.5 70
322
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
The space necessary to remove the M12x1 female connector is at least 22 mm.
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be un-
dertaken by the manufacturer.
1)
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
2)
Please order plug M12x1 separately. Straight plug recommended - no defined position possible for angled plug.
Features:
• High corrosion protection
• Solenoid connection:
- Standard (as per EN175301-803)
- AMP Junior Timer
- DT04-2P “Deutsch”
• Robust design for rough applications
A B
Technical data
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Weight [kg] 4.8 (1 solenoid), 6.3 (2 solenoids)
Vibration resistance [g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 (see shift limits)
Leakage at 50 bar [ml/min] Up to 20 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 105
De-energized: 85
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class Standard (as per EN175301-803) IP65 in acc. with EN60529 (with correctly mounted plug-in
connector)
AMP Junior Timer IP67 in acc. with EN60529 (with correctly mounted plug-in connector)
DT04-P2 “Deutsch” IP69K (with correctly mounted plug-in connector)
Code K J
Supply voltage / ripple [V] 12 V = 24 V =
Tolerance supply voltage [%] ±10 ±10
Current consumption [A] 3 1.5
Power consumption [W] 36 36
Solenoid connection Connector as per EN 175301-803 (code W), AMP Junior Timer (code A), DT04-2P
“Deutsch” connector (code J). Solenoid ident. as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D 3 M W
Directional Size 3-chamber Wet pin Spool Spool
control DIN NG10 valve for solenoid type position
valve CETOP 05 mobile and
2
NFPA D05 marine
applications
3 position spools
Code Spool type
a 0 b
001
021 2 positions.
E
Spring offset in position “0“.
022 Operated in Operated in
position “a“. position “b“.
081
082 2 positions.
F
Operated in position “0“.
Spring offset in Spring offset in
2 position spools position “b“. position “a“.
Code Spool type
a b
020 2 positions.
K
Spring offset in position “0“.
Operated in Operated in
030
position “b“. position “a“.
2 positions.
M
Operated in position “0“.
Spring offset in Spring offset in
position “a“. position “b“.
2 position spools
Code Spool position
2 positions.
B Spring offset in position “b“.
Operated in position “a“.
2 positions.
D Operated in position “a“ or “b“.
No center or offset position.
2 positions.
H Spring offset in position “a“.
Operated in position “b“.
1)
Consider specific spool position.
2)
Please order plug separately.
3)
Only for voltage 24 V=. Further spool types on request.
D3MW UK.indd RH 17.04.2015
1P
Seals Solenoid Connection Solenoid Anti corrosion Design
voltage options coating acc. to series
DIN 50021SS, (not required
2
200h for ordering)
for extreme
conditions
Code Solenoid option
manual override
omit
(Standard)
without manual
T
override
Code Connection
Connector as
W 2)
per EN 175301-803
2-pin AMP
A 2) 3)
Junior Timer
Connector
J 2) 3)
DT04-P2 “Deutsch“
Code Voltage
K 12 V=
J 24 V=
Code Seals
N NBR
V FPM
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
2
Position „b” Position „a” Position „0”
Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T A->B
001 6 5 6 6 – – – – – –
002 3 5 3 3 1 1 4 5 1 6
004 5 4 4 4 – – 8 8 – 9
006 1 2 1 3 2 2 – – – 3
011 2 2 2 2 – – 10 10 – 10
020 6 6 5 7 – – – – – –
030 4 5 3 5 – – – – – –
P->B A->T P->A B->T P->A P->B A->T B->T P->T A->B
008 8 7 7 6 – – – – 9 –
Position „b” Position „a”
P->A P->B A->B P->B A->T
021 2 4 8 3 2
P->A B->T P->A P->B A->B
022 3 2 3 2 8
18
7
16
6
14
5
12
4
10
3
8
2
6
1
4
2
0
0 50 100 150
Flow [l/min]
The diagram below specifies the shift limits for valves with conditions. The shift limits can be considerably lower at
DC solenoids. Valves with spool position “F” or “M” can unbalanced flow conditions. To avoid flow rates beyond
only be operated up to 70 % of the limits. The specifica- the shift limits, a plug-in orifice can be inserted in the
tions apply to a viscosity of 40 mm2/s and balanced flow P-port.
Interface EN 175301-803
B, E, F -style H, K, M -style
C, D -style
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D81VW D111VW
D81VW
3 position spools
D31D
D31N
D111
D41
005 • • • •
2 positions.
K
006 • • • • Operated in Operated in Spring offset in position “0“.
position “b“. position “a“.
007 • • •
0091) • • • • • 2 positions.
M
Spring offset in Spring offset in Operated in position “0“.
011 • • • •
position “a“. position “b“.
014 • • •
W
Pilot oil Seals Solenoid Connector Solenoid Acces- Design
supply and voltage as per options sories series
drain options EN 175301-803, (not required
2
without plug for ordering)
(Please order plug
separately) Code Accessories
Standard valve
omit
w/o accessories
3A Pilot choke, meter-out
3B Pilot choke, meter-in
Pilot with pressure
3C
reducing valve
3D 6) Stroke adjustment side B
3E 6) Stroke adjustment side A
Stroke adjustment
3F 6)
side A and B
meter-out + pressure
3R
reducing valve
meter-in + pressure
1T
reducing valve
Code Seals
N NBR
V FPM
3 position spools
D31D
D31N
D111
D41
005 • • • 2 positions.
E
Operated in Operated in Spring offset in position “0“.
006 • • •
position “a“. position “b“.
007 • •
2 positions.
0091) • • • • • F 2)
Spring offset in Spring offset in Operated in position “0“.
011 • • • • position “b“. position “a“.
014 • •
2 positions.
K
015 • • • • Operated in Operated in Spring offset in position “0“.
021 • • • • 2 positions.
M 2)
022 • • • • Spring offset in Spring offset in Operated in position “0“.
position “a“. position “b“.
031 •
026 • • •
030 • • • • •
Attention:
The adjustment of the position control is factory set and sealed.
Replacement and repairs can only be undertaken by the manufacturer.
D3-D11 UK.indd RH 10.11.2015
W
Pilot oil Seals Solenoid Connector Solenoid Acces- Design
supply and voltage as per options sories series
drain options EN 175301-803, (not required
2
without plug for ordering)
(Please order plug
separately) Code Spool position Position control
End position
I3N 7) monitored, side A
and B
C
Start position
I6N 7) monitored, side A
and B
End position
I2N 7)
C, B, E, F (all spools) monitored, side B
C, K, M (spool 009) Start position
I5N 7)
monitored, side B
End position
I1N 7)
C, H, K, M (all spools) monitored, side A
C, E, F (spool 009) Start position
I4N 7)
monitored, side A
Code Seals
N NBR
V FPM
General
Design Directional spool valve
Actuation Solenoid
Series D31DW D31NW D41VW D81/91VW D111VW
Size NG10 NG10 NG16 NG25 NG32
2
Weight (1/ 2 solenoids) [kg] 6.0 / 6.6 7.6 / 8.1 9.7 / 10.3 17.9 / 18.6 67.4 / 68.0
Mounting interface DIN 24340 A10 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D05 NFPA D05 NFPA D07 NFPA D08 NFPA D10
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60 (without inductive position control)
[°C] 0...+60 (with inductive position control)
MTTFD value [years] 75
Hydraulic
Max. operating pressure [bar] Pilot drain internal: P, A B, X: 350; T, Y: 105
[bar] Pilot drain external: P, A B, T, X: 350; Y: 105
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70), (without inductive position control)
[°C] 0...+70 (with inductive position control)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 170 300 700 2000
Leakage at 350 bar (per flow path) [ml/min] up to 100* 72...422* up to 200* up to 800* up to 5000*
*depending on spool
Opening pressure integral check valve [bar] n.a. see p/Q diagram see p/Q diagram see p/Q diagram n.a.
Minimum pilot supply pressure [bar] 5 7 5
Static / Dynamic
Step response at 95 % [ms] Energized / De-energized
DC solenoids Pilot pressure 50 bar 60 / 40 50 / 60 95 / 65 150 / 170 470 / 390
100 bar 55 / 40 50 / 60 75 / 65 110 / 170 320 / 390
250 bar 55 / 40 50 / 50 60 / 65 90 / 170 210 / 390
350 bar 55 / 40 50 / 50 60 / 65 85 / 170 200 / 390
AC solenoids Pilot pressure 50 bar 40 / 30 30 / 50 75 / 55 130 / 155 450 / 375
100 bar 35 / 30 30 / 50 65 / 55 90 / 155 300 / 375
250 bar 35 / 30 30 / 50 40 / 55 70 / 155 190 / 375
350 bar 35 / 30 30 / 50 40 / 55 65 / 155 180 / 375
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G Y T
110 V at 50 Hz/ 230 V at 50 Hz/
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V =
120 V at 60 Hz 240 V at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.58 / 0.49 0.31 / 0.26
Current consumption in rush [A] 2.72 1.29 0.33 0.13 2.1 / 2.0 1.05 / 1.0
Power consumption hold 32.7 W 31 W 31.9 W 28.2 W 64 / 59 VA 68 / 62 VA
Power consumption in rush 32.7 W 31 W 31.9 W 28.2 W 231 / 240 VA 231 / 240 VA
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
1 + US 19.2...28.8 V
2 Out B: normally open
3 0V
4 Out A. normally closed
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the spring is reached (above 85 % spool stroke).
offset position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
1)
Only guaranted with screened cable and female connector
The flow curve diagrams show the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the tables below.
001 4 3 4 3 – – 3 2 3 5
002 2 3 3 3 3 7 3 4 4 3
003 2 2 4 3 – – 1 4 2 4
004 4 2 3 3 – – 2 4 3 4
005 1 2 4 4 – – 2 1 3 4
006 2 8 3 9 – – 3 7 4 9
007 4 – 2 – 5 – 2 – 2 –
009 2 4 2 6 8 6 5 4 6 10
011 3 3 2 3 – – 3 2 3 4
014 2 – 4 – 5 – 2 – 3 –
D31NW
015 4 2 2 2 – – 2 1 2 4
016 4 4 1 3 – – 1 2 2 4
020 4 6 4 4 – – 4 3 4 6
021 3 – 4 7 – – 2 8 – –
022 5 4 2 – – – – 9 4 –
026 3 – 3 – – – – – – –
030 4 5 3 3 – – 3 2 3 5
031 3 – 4 – – – 1 – – –
032 5 – 2 – – – – – 2 –
081 6 – 6 – – – 7 – 7 –
082 7 – 6 – – – 5 – 7 –
D41VW D41VW
Spool Curve number
Code P-A P-B P-T A-T B-T
001 1 1 – 4 5
002 1 2 6 4 6
003 1 2 – 5 6
004 1 1 – 5 5
005 2 2 – 3 5
006 1 2 – 3 6
007 1 1 6 4 5
009 2 9 8 7 10
011 1 1 – 4 5
014 1 1 6 4 5
015 1 2 – 4 6
016 2 2 – 3 5
020 3 5 – 3 5
021 2 8 – 2 –
022 8 2 – – 3
026 3 5 – – –
030 2 3 – 6 7
031 – – – – –
032 – – – – –
054 2 3 – 6 7
081 – – – – –
082 – – – – –
All characteristic curves measured with HLP46 at 50 °C.
D31DW
D31NW
D41VW
D81/91VW
open, closed
A B
P T
C M6 DIN906 Pilot oil
Inlet Outlet A B C a 0 b
B M6 DIN906 internal external Orifice Ø1.5
A 1/16 NPTF external external Orifice Ø1.5
a b
0
internal internal Orifice Ø1.5
external internal Orifice Ø1.5
P X Y T
A C B
D111VW
D31DW
Surface finish
D31NW
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
* Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out).
D41VW
Surface finish
4x M10x60
63 Nm ±15 % NBR: SK-D41VW-N-91
BK320 2x M6x55
13.2 Nm ±15 % FPM: SK-D41VW-V-91
ISO 4762-12.9
D81VW, D91VW
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
* Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out).
D111VW
Surface finish
The space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
* Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out).
2
Pilot operated valves:
chapter 12)
A B A B A B
T P
T P T P
D3DWR
D3DW C J W
Direct operated Spool 3 spool Drain port Seals Solenoid Connector Solenoid Design
2
valve NG10 type position voltage as per options series
Spring offset in 24 V = EN 175301-803, (not required
position “0“. without con- for ordering)
Operated in position nector
“a“ or “b“. (Please order plug
separately)
R04
Code Seals
N NBR
R81 V FPM
R82
1)
For regenerative and hybrid function please refer to solutions with sandwich- and adaptor plates "A10-1664 / A10-1665L / H10-1662 / H10-1666L" in chapter 12.
C J W
Series Spool 3 spool Pilot oil Seals Solenoid Connector Solenoid Acces- Design
2
type position supply and voltage as per options sories series
Spring offset in drain options 24 V = EN 175301-803, (not required
position “0“. without con- for ordering)
Operated in position nector
“a“ or “b“. (Please order plug
separately)
R54 4) Z54 4)
Code Seals
N NBR
Code Inlet Outlet
V FPM
1 Internal External
2 External External
4 Internal Internal
5 External Internal
1)
Not for D31NW.
2)
For regenerative and hybrid function for D31NW (NG10) please refer to solutions with sandwich- and adaptor plates "A10-1664 / A10-1665L / H10-1662 / H10-1666L" in
chapter 12.
D31NW spool type: R01 , R04
R81 , R82
3)
Not for D111VW.
4)
Only for D111VW.
General
Design Directional spool valve
Actuation Solenoid
Series D3DWR D31NWR D41VW D81/91VW D111VW
Size NG10 NG10 NG16 NG25 NG32
Weight [kg] 6.3 8.1 10.3 18.6 68.0
Mounting interface DIN 24340 A10 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401
NFPA D05
ISO 4401
NFPA D05
ISO 4401
NFPA D07
ISO 4401
NFPA D08
ISO 4401
NFPA D10
2
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 75 / 150 (D3DWR)
Hydraulic
Max. operating pressure [bar] D3DWR: P, A B: 350; T: 210; option 9 1) : P, A, B, T: 350; X, Y: 210
Pilot drain internal: P, A B, X: 350; T, Y: 105
Pilot drain external: P, A B, T, X: 350; Y: 105
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 170 300 700 2000
Leakage at 350 bar (per flow path) [ml/min] up to 20* 72...422* up to 200* up to 800* up to 5000*
*depending on spool (at 50 bar)
Minimum pilot supply pressure [bar] — 7 5
Static / Dynamic
Step response at 95 % [ms] Energized / de-energized
DC solenoids at 65 l/min 175 bar 105 / 85 — — — —
DC solenoids Pilot pressure 50 bar — 50 / 60 95 / 65 150 / 170 470 / 390
100 bar — 50 / 60 75 / 65 110 / 170 320 / 390
250 bar — 50 / 50 60 / 65 90 / 170 210 / 390
350 bar — 50 / 50 60 / 65 85 / 170 200 / 390
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
D3DWR D31NWR / D41VW / D91VW / D111VW
Supply voltage / ripple [V] 24 V = 24 V =
Tolerance supply voltage [%] ±10 ±10
Current consumption hold [A] 1.5 1.29
Current consumption in rush [A] 1.5 1.29
Power consumption hold [W] 36 31
Power consumption in rush [W] 36 31
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
1)
Bolts are not designed for simultaneous loading of all ports with maximum pressure.
The total pressure profile has to be adapted to the tensile strength of the bolts.
D3DWR
A-B (R04, Pos „0")
20 A-T, B-T (R04, Pos. „0")
2
14 B-T (R01, Pos. „b“),
12 P-A (R04, Pos. „b“)
D31NWR
9
Pressure drop p [bar]
B-T (R01)
A-T, B-T (R04)
P-A, P-B (R01), P-B (R04)
A-T (R01), P-A (R04)
6
0
0 30 60 90 120 150 170
Flow Q [l/min]
D41VW
D91VW
D111VW
D31NW on request.
2
D31NWR
D41VWR D41VWZ
D91VWR D91VWZ
D111VWR D111VWZ
D3DWR
Regenerative and hybrid function with additional plate ”H10-1666L / H10-1662 / A10-1664 / A10-1665L“,
see chapter 12
Ø11
2
114
77
79
30
A B
Ø6.8
123 23
300 70
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D31NWR
Regenerative and hybrid function with additional plate ”H10-1666L / H10-1662 / A10-1664 / A10-1665L“,
see chapter 12
Surface finish
D41VWR/Z
Surface finish
4x M10x60
63 Nm ±15 % NBR: SK-D41VW-N-91
BK320 2x M6x55
13.2 Nm ±15 % FPM: SK-D41VW-V-91
ISO 4762-12.9
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
* Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out).
D91VWR/Z
Surface finish
D111VW
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
* Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out).
General
Design Directional spool valve
Actuation Hydraulic
Series D1VP*4L D1VP*90 D3DP D4P D9P D11P
Size NG06 NG06 NG10 NG16 NG25 NG32
Weight [kg] 1.3 1.3 3.7 9.0 17.0 66.0
Mounting interface DIN 24340 A06 DIN 24340 A06 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D03 NFPA D03 NFPA D05 NFPA D07 NFPA D08 NFPA D10
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Hydraulic
P, A B: 350; P, A B; T: 350; P, A B, T: 350; P, A B, T: 350; P, A B, T: 350; P, A B, T: 350;
Max. operating pressure [bar]
T: 140 X, Y: 210 X, Y: 210 X, Y: 350 X, Y: 350 X, Y: 350
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 60 1) 60 1) 130 300 700 2000
Leakage at 350 bar (per flow path) [ml/min] up to 60 2) up to 60 2) up to 100 2) up to 200 2) up to 800 2) up to 5000 2)
Operating pressure (min/max) [bar] 10 3) / 210 15 / 210 15 / 210 5 / 350 5 / 350 5 / 350
Pilot volume (start position to end position) [cm3] 0.59 0.34 1.1 4.2 12.3 59.7
Static / Dynamic
Step response The response times depend on the pilot oil pressure and on the speed of the increase /
decrease of the pilot pressure.
1)
Depending on spool, see shift limits. 2)
Depending on spool. 3)
> tank pressure.
D 1 V P
Directional Size 3-chamber Hydraulically Spool Spool Seals Pilot port Design
control DIN NG06 design operated type position G1/8 series
valve CETOP 03 (not required
2
NFPA D03 for ordering)
004
2 positions.
E
Operated in Operated in Spring offset in position “0“.
position “a“. position “b“.
2 positions.
F
Spring offset in Spring offset in Operated in position “0“.
position “b“. position “a“.
2 positions.
K
Operated in Operated in Spring offset in position “0“.
position “b“. position “a“.
2 positions.
M
Spring offset in Spring offset in Operated in position “0“.
position “a“. position “b“.
2 position spools 2)
Code Spool position
Spring offset in position “b“.
B
Operated in position “a“.
1)
Consider specific spool position.
2)
Code 4L without ports X and Y. Further spool types and styles on request.
D_P UK.indd RH 17.04.2015
D 3 D P 2
Directional Size 5-chamber Hydraulically Spool Spool Pilot oil Seals Design
control DIN NG10 design operated type position supply and series
valve CETOP 05 drain external/ (not required
for ordering)
2
NFPA D05 external
002
003
004
005
006
014
2 positions.
E
015 Operated in Operated in Spring offset in position “0“.
021 2 positions.
F
022 Spring offset in Spring offset in Operated in position “0“.
position “b“. position “a“.
031
032 2 positions.
K
Operated in Operated in Spring offset in position “0“.
081
position “b“. position “a“.
082
102 2 positions.
M
Spring offset in Spring offset in Operated in position “0“.
2 position spools position “a“. position “b“.
Code Spool type
a b 2 position spools
020 Code Spool position
1)
Consider specific spool position. Further spool types and styles on request.
D_P UK.indd RH 17.04.2015
D P
Directional Size Hydraulically Spool Spool
control operated type position
valve
2
Code Bore Size
4 Ø20 mm NG16
9 Ø32 mm NG25
11 Ø50 mm NG32
3 position spools
Code Spool position
3 position spools
D11
3 positions.
D4
D9
003 • • 2 positions.
E
Operated in Operated in Spring offset in position “0“.
004 • • • position “a“. position “b“.
005 • •
2 positions.
006 • • F
Spring offset in Spring offset in Operated in position “0“.
007 • • position “b“. position “a“.
009 1) • • •
2 positions.
011 • • K
Operated in Operated in Spring offset in position “0“.
014 • • position “b“. position “a“.
015 • •
2 positions.
M
016 • • Spring offset in Spring offset in Operated in position “0“.
position “a“. position “b“.
021 • •
D9
1)
Consider specific spool position.
2)
Only D4 and D9 available.
2
Pilot oil Seals Accessories Design
supply and series
drain external/ (not required
for ordering)
2
external
Code Accessories
Standard valve
omit
w/o accessories
Pilot choke,
3A
meter-out
Pilot choke,
3B
meter-in
Stroke adjustment
3D 2)
side B
Stroke adjustment
3E 2)
side A
Stroke adjustment
3F 2)
side A and B
Code Seals
N NBR
V FPM
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
2 002
004
1
2
4
3
1
2
4
3
1
–
1
–
5
7
5
7
2
–
006 1 4 1 4 7 7 – – –
020 4 4 2 3 – – – – –
026 4 – 4 – – – – – –
030 2 3 1 2 – – – – –
P->B A->T P->A B->T P->A P->B A->T B->T P->T
008 4 5 4 5 – – – – 8
009 5 5 6 7 – – – – 7
Flow curves
Shift limits
Spool Shift limit [l/min]
001
002
004
60
006
020
030
008
40
009
026 20
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
Position „b“ Position „a“ Position „0“
Spool P-A B-T P-B A-T P-A P-B A-T B-T P-T A-B
001 4 3 4 3 – – – – – –
002
003
2
2
4
2
3
4
3
1
2
–
2
–
1
5
2
–
3
–
4
–
2
004 4 3 3 2 – – 5 5 – 6
005 1 3 4 2 4 – – – – –
006 2 4 3 3 5 5 – – – 6
007 4 2 2 2 – 2 – 2 5 –
010 2 – 2 – – – – – – –
011 3 3 2 3 – – 10 10 – 11
014 2 3 4 2 2 – 2 – 5 –
015 4 2 2 2 – – – 4 – –
016 4 2 1 1 – 4 – – – –
020 4 4 4 4 – – – – – –
026 3 – 3 – – – – – – –
030 4 3 3 3 – – – – – –
081 6 7 6 7 – – – – – –
082 7 7 6 5 – – 11 11 – 11
101 9 9 9 9 – – – – – –
102 2 2 2 1 6 6 3 5 6 6
P-B A-T P-A B-T P-A P-B A-T B-T P-T A-B
008 4 2 5 6 8
009 2 5 2 6 – – – – 8 –
Position „b“ Position „a“ Position „0“
P-A B-T A-B P-B A-T A-T
021 3 5 6 4 2 – – –
031 3 5 6 4 1 – 9 –
P-A B-T P-A P-B A-B B-T
022 5 4 – 5 2 6 – –
032 5 2 – 5 2 6 – 9
Flow curves
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
D4P D4P
Spool Curve number
2 Code
001
P-A
1
P-B
1
P-T
–
A-T
4
B-T
5
002 1 2 6 4 6
003 1 2 – 5 6
004 1 1 – 5 5
005 2 2 – 3 5
006 1 2 – 3 6
007 1 1 6 4 5
009 2 9 8 7 10
011 1 1 – 4 5
014 1 1 6 4 5
015 1 2 – 4 6
016 2 2 – 3 5
020 3 5 – 3 5
021 2 8 – 2 –
022 8 2 – – 3
026 3 5 – – –
030 2 3 – 6 7
054 2 3 – 6 7
D1VP*90
Surface finish
D1VP*4L
Surface finish
D3DP
Ø11
77
30
A B
Ø6.5
88
121 70
Surface finish
D4P
B A
Stroke
adjustment
134
44.5
A B
11 Ø11
92 63 165
94 101
Surface finish
4x M10x60
63 Nm ±15 % NBR: SK-D41VW-N-91
BK320 2 x M6x55
13.2 Nm ±15 % FPM: SK-D41VW-V-91
ISO 4762-12.9
D9P
B A
Stroke
adjustment
2
155
57
A B
12 Ø13.5
116 76 230
118 117
Surface finish
D11P
B A
254
59
A B
20 Ø22
198 90 319
200
Surface finish
A B
Technical data
General
Design Directional spool valve
Actuation Pneumatic
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A06, ISO 4401, NFPA D03, CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Weight [kg] 1.3
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 105
Fluid Hydrauliköl nach DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 60 1)
Leakage at 350 bar (per flow path) [ml/min] up to 60 1)
Operating pressure w/o tank pressure [bar] min. 3
with max tank [bar] min. 5
Static / Dynamic
Step response The response times depend on the pilot oil pressure and on the speed of the increase /
decrease of the pilot pressure.
Recommended values are (act./deact.)
depending on pilot pressure and pipe [ms] 13/28
length
1)
Depending on spool.
D 1 V A 4L
Directional Size 3-chamber Pneumatically Spool Spool Seals Indirect ac- Design
control DIN NG06 design operated type position tuation via series
valve CETOP 03 pilot spool; (not required
2
NFPA D03 G1/8 for ordering)
004
3 position spools
006 Code Spool position
008 1) 3 positions.
C Spring offset in position “0“.
009 1) Operated in position “a“ or “b“.
Spool type 008,
Standard
2 position spools 009
Code Spool type
a b
2 positions.
020 E
Operated in Operated in Spring offset in position “0“.
026 position “a“. position “b“.
030
2 positions.
F
Spring offset in Spring offset in Operated in position “0“.
position “b“. position “a“.
2 positions.
K
Operated in Operated in Spring offset in position “0“.
position “b“. position “a“.
2 positions.
M
Spring offset in Spring offset in Operated in position “0“.
position “a“. position “b“.
2 position spools
Code Spool position
Spring offset in position “b“.
B
Operated in position “a“.
Detent, operated in position
D “a“ or “b“. No centre or offset
position.
Spring offset in position “a“.
H
Operated in position “b“.
1)
Consider specific spool position. Further spool types and styles on request.
D1VA UK.indd RH 17.04.2015
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
2 002
004
1
2
4
3
1
2
4
3
1
–
1
–
5
7
5
7
2
–
006 1 4 1 4 7 7 – – –
020 4 4 2 3 – – – – –
026 4 – 4 – – – – – –
030 2 3 1 2 – – – – –
P->B A->T P->A B->T P->A P->B A->T B->T P->T
008 4 5 4 5 – – – – 8
009 5 5 6 7 – – – – 7
Flow curves
Shift limits
Spool Shift limit [l/min]
001
002
004
60
006
020
030
008
40
009
026 20
B, E, F -style
H, K, M -style
C, D -style
Surface finish
Features
• All hand lever parts stainless steel
D1VL
Technical data
General
Design Directional spool valve
Actuation Lever
Series D1VL D3DL D4L D9L
Size NG06 NG10 NG16 NG25
Weight [kg] 1.4 3.7 9.0 17.0
Mounting interface DIN 24340 A06 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25
ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D03 NFPA D05 NFPA D07 NFPA D08
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Hydraulic
Max. operating pressure [bar] external drain external drain
P, A B, T: 350; P, A B, T: 350;
P, A B: 350; P, A B: 350; X, Y: 140 X, Y: 140
T: 140 T: 140 internal drain internal drain
P, A B: 350; P, A B: 350;
T, X, Y: 140 T, X, Y: 140
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 80 130 300 700
Leakage at 350 bar (per flow path) [ml/min] – up to 100 1) up to 200 1) up to 800 1)
Leakage at 50 bar (per flow path) [ml/min] up to 10 1) – – –
1)
Depending on spool.
D 1 V
Directional Size 3-chamber Actuation Spool Spool Seals Switching Design
control DIN NG06, valve type position logic series
valve CETOP 03 (not required
2
NFPA D03 for ordering)
009 1) 2 positions.
E
Spring offset in position “0“.
042 Operated in Operated in
position “a“. position “b“.
2 position spools
Code Spool type
a b 2 positions.
K
020 Spring offset in position “0“.
Operated in Operated in
position “b“. position “a“.
3 positions, detent.
N
Operated in position “a“, “0“or “b“.
No centre in offset No centre in offset
position. position.
2 positions, detent.
R
Operated in position “0“ or “b“.
No centre in offset No centre in
position. offset position.
2 positions, detent.
S Operated in position “0“ or “a“.
No centre in offset No centre in No center in offset position.
position. offset position.
2 position spools
Code Spool position
D 3 D
Directional Size 5-chamber Actuation Spool Spool Seals Switching Design
control DIN NG10, valve type position logic series
valve CETOP 05 (not required
2
NFPA D05 for ordering)
009 1) 2 positions.
E
Spring offset in position “0“.
010 Operated in Operated in
position “a“. position “b“.
2 position spools
Code Spool type 2 positions.
a b K
Spring offset in position “0“.
Operated in Operated in
020
position “b“. position “a“.
3 positions, detent.
N
Operated in position “a“, “0“or “b“.
No centre in offset No centre in offset
position. position.
2 positions, detent.
R
Operated in position “0“ or “b“.
No centre in offset No centre in
position. offset position.
2 positions, detent.
S Operated in position “0“ or “a“.
No centre in offset No centre in No center in offset position.
position. offset position.
2 position spools
Code Spool position
1)
Consider specific spool position.
2)
Details see dimensions. Further spool types on request.
D_L UK.indd RH 17.04.2015
D
Directional Size Actuation Spool Spool Pilot oil Seals Design
control type position drain series
valve (not required
2
for ordering)
2 positions.
E
Spring offset in position “0“.
Operated in Operated in
3 position spools position “a“. position “b“.
D4
D9
007 • •
2 positions.
M
009 1) • • Spring offset in position “a“.
Operated in Operated in
011 • • position “0“. position “0“.
The flow curve diagrams show the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the tables below.
D1VL
Position „b“ Position „a“ Position „0“
Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T
2
001 2 2 2 2 – – – – –
002 1 4 1 4 1 1 5 5 2
004 2 3 2 3 – – 7 7 –
006 1 4 1 4 7 7 – – –
020 4 4 2 3 – – – – –
P->B A->T P->A B->T P->A P->B A->T B->T P->T
009 5 5 6 7 – – – – 7
D3DL
Position „b“ Position „a“ Position „0“
Spool P-A B-T P-B A-T P-A P-B A-T B-T P-T A-B
001 4 3 4 3 – – – – – –
002 2 4 3 3 2 2 1 2 3 4
004 4 3 3 2 – – 5 5 – 6
006 2 4 3 3 5 5 – 6
020 4 4 4 4 – – – – – –
P-B A-T P-A B-T P-A P-B A-T B-T P-T A-B
009 2 5 2 6 – – – – 7 –
The flow curve diagrams show the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the tables below.
D4L
Curve number
Spool
001
P-A
1
P-B
1
P-T
–
A-T
4
B-T
5
2
002 1 2 6 4 6
003 1 2 – 5 6
004 1 1 – 5 5
006 1 2 – 3 6
007 1 1 6 4 5
009 2 9 8 7 10
011 1 1 – 4 5
014 1 1 6 5 4
015 2 1 – 6 5
020 3 5 – 3 5
030 2 3 – 6 7
D9L
Curve number
Spool P-A P-B P-T A-T B-T
001 3 2 - 3 5
002 2 1 1 3 5
003 4 2 - 3 6
004 4 3 - 3 5
007 3 1 7 3 5
009 4 8 9 4 10
014 1 3 7 5 3
015 2 4 - 5 3
020 6 5 - 6 8
030 3 2 - 3 5
D1VL*4J
D1VL*4K
Surface finish
D1VLB*4J
Surface finish
D3DL*4J
Surface finish
D3DL*4K
D3DLB*4J
Surface finish
D4L
D4LB
Surface finish
4x M10x60 63 Nm
NBR: SK-D4L-N-91
BK320 2x M6x55 13.2 Nm
FPM: SK-D4L-V-91
ISO 4762-12.9 ±15 %
D9L
D9LB
Surface finish
Fig. 1 and 5
5001575
5001708
5001576
5001709
2
Plug with rectifier:
Bridge-type rectifier with silicon diodes. Varistors are used to protect the Fig. 1 and 6 5001737 5001738
diodes against power surges from the power supply up to 250VAC. PG 11
Plug with cable strain relief and transparent cover Fig. 2 5001723 5001724
Inserts for plug 5001723 and 5001724 Cicuit Order no.
Bridge-type rectifier up to 250VAC 7 7 5001727
Bridge-type rectifier with lamp 250VAC 8 5001734
Plug M12x1, order no.: 5004109 Plug kit 2-pin Junior Timer (AMP)
Order no. Number of plugs in 1 kit
393 000 K822 1
393 000 K825 10
The angled plug for M12x1 393 000 K826 50
is a 5-pin design. The con-
nections in the plug can be 393 000 K827 100
screwed in. The plug can be
turned 4 x 90°.
Plug kit DT04-2P “Deutsch“
Order no. Number of plugs in 1 kit
45216087 1
1)
(New) EN 175301-803 corresponds to (old) DIN 43650.
Access02.indd RH 17.04.2015
D1VW 8 Watt
Solenoid kits: AK-D1VWS... Coil kits: AK-D1VWC...
M12x1 „DESINA“ M12x1 „DESINA“
Voltage Voltage EN plug (Code „DLJ5“) EN plug (Code „DLJ5“)
Volt/Hertz Code D1VW D1VW D1VW D1VW
24 V= J JWL91 JDLJ591 JWL91 JDLJ591
D3W
Solenoid kits: AK-D3WS... (Soft shift on request) (Example: AK-D3WSJW30) Coil kits: AK-D3WC...
EN plug without manual EN plug with 210bar tank EN plug without manual
Voltage Voltage EN plug override (Code „T“) pressure (Code „H“) EN plug override (Code „T“)
Volt/Hertz Code D3W D3W D3W D3W D3W
12 V= K KW30 KWT30 KW30 KW30 KWT30
24 V= J JW30 JWT30 JW30 JW30 JWT30
98 V= U UW30 UWT30 UW30 UW30 UWT30
205 V= G GW30 GWT30 GW30 GW30 GWT30
110 V/50 Hz
Y YW30 – YWH30 YW30 –
120 V/60 Hz
230 V/50 Hz
T TW30 – TWH30 TW30 –
240 V/60 Hz
Access02.indd RH 17.04.2015
DIN NG10 D3
P, A, B, T
X, Y
12.42 x 1.78
10.82 x 1.78
5
2 2
P, A, B, T 21.89 x 2.62 4
DIN NG16 D4
X, Y 10.82 x 1.78 2
P, A, B, T 29.82 x 2.62 4
DIN NG25 D8
X, Y 20.29 x 2.62 2
P, A, B, T 34.59 x 2.62 4
DIN NG25 D9
X, Y 20.29 x 2.62 2
P, A, B, T 53.57 x 3.53 4
DIN NG32 D11
X, Y 14.00 x 1.78 2
Seated valve
Valve
Material D1SE
series
D1SE NBR SK-D1SE-70
Solenoid FPM SK-D1SE-V70
1)
Number per set
Access02.indd RH 17.04.2015
Slip-in orifice for P, A, B port of directional control valves NG06 and NG10
DK
Dimensions
NG06 NG10
Ø10.8
Ød
6
1.1
Ø11.7
1)
Only for ports P, A, B with max. dia. 7.5 mm.
Access02.indd RH 17.04.2015
Size 6, mounting pattern to ISO 4401-03-03-0-05 Size 10, mounting pattern to ISO 4401-05-05-0-05
With * marked dimensions ± 0.1 mm. All other dimensions ± 0.2 mm.
Subplates and manifolds see chapter 12.
Access02.indd RH 17.04.2015
With * marked dimensions ± 0.1 mm. All other dimensions ± 0.2 mm.
Subplates and manifolds see chapter 12.
Access02.indd RH 17.04.2015
Oper- Elec-
Series Description Size LVDT Spool Design Page
ation tronics
DIN/ISO
onboard
external
Spool/
Overlap Zero lap
direct
sleeve
pilot
Introduction 3-2
Standard
D1FB NG06 • • • optional optional 3-3
D1FB OBE
D3FB
NG06 •
NG10 • •
• •
•
optional optional
optional 3-14
3
D3FB OBE NG10 • • • optional
D1FB CANopen NG06 • • • optional 3-24
D3FB CANopen NG10 • • • optional
D31FB NG10 • • • 3-34
D31FB OBE NG10 • • •
D41FB NG16 • • •
D41FB OBE NG16 • • •
D91FB NG25 • • •
D91FB OBE NG25 • • •
D111FB NG32 • • •
D111FB OBE NG32 • • •
D1FV*3 Pilot valve NG06 • • • 3-50
D1FV*3 OBE Pilot valve NG06 • • •
High repeatability
D1FC NG06 • • • • 3-58
D3FC NG10 • • • • 3-65
D31FC NG10 • • • • 3-72
D41FC NG16 • • • •
D91FC NG25 • • • •
D111FC NG32 • • • •
D*FC, D*1FC EtherCAT • • • • • 3-83
VCD® performance*, for closed loop applications
D1FP NG06 • • • • • • 3-86
D3FP NG10 • • • • • • 3-93
D30FP NG10 • • • • • 3-100
D31FP NG10 • • • • • 3-107
D41FP NG16 • • • • •
D91FP NG25 • • • • •
D111FP NG32 • • • • •
D*FP, D*1FP EtherCAT • • • • • • • 3-118
Accessories
Plug-in connectors 3-121
Actuator kits / coil kits 3-122
Mounting patterns 3-123
Content03.INDD RH 17.04.2015
Proportional valves and servo proportional valves are characterized by a number of design features that determine
their quality to fit into different applications. The main features are listed below.
Intro03.indd RH 17.04.2015
Features
• Spool/sleeve and spool/body
• 3 command options for D1FB OBE:
+/- 10 V, 4…20 mA, +/- 20 mA
• High repeatability from valve to valve
• Low hysteresis
• Manual override
• Digital onboard electronics
• Zero lap spools for the usage in simple closed loop
systems
Parametrizing connection
Main connection
(always on B-side)
Manual
override
D1FB
D 1 F B 0 N
Directional Size Proportional Standard Spool Spool Seals NBR Solenoid Connector Design Design
control DIN NG06 control dynamics type position (other seal series
valve CETOP 03 standard compounds (not required
on request) for ordering)
NFPA D03 repeatability
1) Only for spool position code C. No defined spool positioning at power down.
2) Please order connector separately, see chapter 3 accessories.
3) Not for spool/sleeve design.
D 1 F B 0 N
Directional Size Proportional Standard Spool Spool Seals NBR Input Options Design Design
control DIN NG06 control dynamics type position (other seal signal series
valve CETOP 03 standard compounds (not required
on request) for ordering)
NFPA D03 repeatability
QB = QA /2
B32F 12 / 6
B32H 20 / 10
Zero lap 1)
Code Design
Flow [l/min]
Code Spool type at Dp 35 bar
per metering edge C
E50C 6
E50F 12
E50H 20 E
QB = QA /2
B60F 12 / 6
B60H 20 / 10
K
1) Only for spool position code C. No defined spool positioning at power down.
2) Factory set ± 10 V on delivery.
3) Single solenoid always 0...+10 V respectively 4...20 mA.
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Size NG06/CETOP 03/NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight (OBE) [kg] 2.2 (2.9)
3
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 210
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -25...+60
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 5 bar D1FB*0 (Spool/sleeve) D1FB*3 (Spool/body)
per control edge 2) [l/min] 6 / 12 / 20 10 / 20 / 30
<50 (overlapped spool);
Leakage at 100 bar [ml/min] <60
<400 (zerolapped spool)
Opening point (OBE) [%] see flow characteristics (set to 10 command signal)
Static / Dynamic
Step response at 100 % step [ms] 30 30
Hysteresis [%] <4 <6
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100 ED; CAUTION: Coil temperature up to 150 °C possible
Standard (as per EN 175301-803) IP65 in accordance with EN 60529 (with correctly mounted
Protection class plug-in connector)
DT04-2P “Deutsch“ IP69K (with correctly mounted plug-in connector)
Code "J"
Solenoid Code "M" Code "K"
(Spool/sleeve)
Supply voltage [V] 9 12 24
Current consumption [A] 2.7 2.2 1.1 (0.8)
Resistance [Ohm] 2.7 4.4 18.6
Connector as per EN 175301-803 (code W), DT04-2P “Deutsch“ connector (code J).
Solenoid connection
Solenoid identification as per ISO 9461.
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield (Code W), "Deutsch" connector DP4 2-Pin (Code J)
Wiring lenght max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
Flow rate for different ∆p per control edge: Qx = QNom. ·
2) ∆px
∆pNom.
Code G0
> 3.8 mA = enable on (acc. to NAMUR NE43)
[mA] +20...0...-20, ripple < 0.01 % eff., surge free, Ri = 200 Ohm, 0...+20 mA Þ P -> A
3
Differential input max.
Codes F0, G0 & S0 [V] 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code W5 [V] 30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0V (terminal 2)
Channel recall signal [V] 0...2.5: off / 5...30: on / Ri = 100 kOhm
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, parametrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection
Codes F0, G0 & S0 6 + PE acc. to EN 175201-804
Code W5 11 + PE acc. to EN 175201-804
Wiring min.
Codes F0, G0 & S0 [mm²] 7 x 1.0 (AWG16) overall braid shield
Code W5 [mm²] 11 x 1.0 (AWG16) overall braid shield
Wiring length max. 50
Flow characteristics
D1FB*0 external electronics
at ∆p = 5 bar per metering edge
Spool type E01/02/03, B31/32
D1FB*0 OBE
(set to opening point 10 %)
at ∆p = 5 bar per metering edge
Spool type E01/02/03, B31/32
Functional limits
at 25 %, 50 %, 75 % and 100 % command signal At asymmetric flow a reduced flow limit has to be con-
(symmetric flow) sidered.
Spool type E01H
Flow characteristics
D1FB*3 external electronics
at ∆p = 5 bar per metering edge
Spool type E01/02/03, B31/32
D1FB*3 OBE
(set to opening point 10 %)
at ∆p = 5 bar per metering edge
Spool type E01/02
Functional limits
at 25 %, 50 %, 75 % and 100 % command signal At asymmetric flow a reduced flow limit has to be con-
(symmetric flow) sidered.
Spool type E01K
Code W5
11 + PE acc. to EN 175201-804
D1FB*C
15
85
Ø9.5
22
P
3
Ø5.5
46
A B
T
72.5 17
222
D1FB*E D1FB*K
15
85
Ø9.5
~53
22
P
Ø5.5
P
46
A B
T
72.5 17
158
Ø9.5
68
22
P
Ø5.5
P
46
A B
T
72.5 17
222
Surface finish
NBR
4x M5x30 7.6 Nm
BK375 SK-D1FB
ISO 4762-12.9 ±15 %
D1FB*C OBE
125
Ø9.5
22
P
Ø5.5
46
A B
T
72.5 17
222
Ø9.5
22
P
Ø5.5
P
46
A B
T
72.5 17
158
Surface finish
NBR
4x M5x30 7.6 Nm
BK375 SK-D1FB
ISO 4762-12.9 ±15 %
Parametrizing connection
Main connection
(always on B-side)
Manual
override
D3FB
D 3 F B 0 N W
DC Size Propor- Standard Spool Spool Seal NBR Solenoid Connector Design Design
valve DIN NG10 tional dynamics type position (other seal as per EN series
CETOP 05 control standard compounds 175301-803 (not required
on request) for ordering)
NFPA D05 repeatability without plug 1)
For regenerative and hybrid function refer solution with sandwich and adaptor plates "A10-1664 / A10-1665L / H10-
1662 / H10-1666L" in chapter 12.
D 3 F B 0 N
Directional Size Proportional Standard Spool Spool Seals NBR Input Options Design Design
control DIN NG10 control dynamics type position (other seal signal series
valve CETOP 05 standard compounds (not required
on request) for ordering)
NFPA D05 repeatability
For regenerative and hybrid function refer solution with sandwich and adaptor plates "A10-1664 / A10-1665L / H10-
1662 / H10-1666L" in chapter 12.
Please order connector separately, see chapter 3 accessories.
Parametrizing cable OBE ® RS232: Item no. 40982923
1)
Single solenoid always 0...+10 V respectively 4...20 mA.
2)
Factory set ±10 V on delivery.
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Size NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight (OBE) [kg] 6.5 (7.2)
3
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350, T 210
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -25...+60
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
D3FB*0 (Spool/sleeve) D3FB*3 (Spool/body)
Nominal flow
40 / 60 40 / 60 / 80
at ∆p=5 bar per control edge 2) [l/min]
Leakage at 100 bar [ml/min] <100 <100
Opening point (OBE) [%] see flow characteristics (set to 10 command signal)
Static / Dynamic
Step response at 100 % step [ms] 40
Hysteresis [%] <4 <5
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100 ED; CAUTION: Coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Solenoid Code “K“ Code “J“
Supply voltage [V] 12 24
Current consumption [A] 2.95 1.5
Resistance [Ohm] 3.84 16.25
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring lenght max. [m] 50 recommended
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
Flow rate for different ∆p per control edge:
2)
Qx = QNom. · ∆px
∆pNom.
3 Code G0
> 3.8 mA = enable on (acc. to NAMUR NE43)
[mA] +20...0...-20, ripple < 0.01 % eff., surge free, Ri = 200 Ohm, 0...+20 mA Þ P -> A
Differential input max.
Codes F0, G0 & S0 [V] 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code W5 [V] 30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0V (terminal 2)
Channel recall signal [V] 0...2.5: off / 5...30: on / Ri = 100 kOhm
Min [%] 0...50
Adjustment ranges Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, parametrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection
Codes F0, G0 & S0 6 + PE acc. to EN 175201-804
Code W5 11 + PE acc. to EN 175201-804
Wiring min.
Codes F0, G0 & S0 [mm²] 7 x 1.0 (AWG16) overall braid shield
Code W5 [mm²] 11 x 1.0 (AWG16) overall braid shield
Wiring length max. 50
Flow characteristics
D3FB external electronics
at Dp = 5 bar per metering edge
Spool type E01/02, B31/32
D3FB OBE
(set to opening point 10 %)
at ∆p = 5 bar per metering edge
Spool type E01/02, B31/32
Functional limits
100 % command signal (symmetric flow). At asymmetric flow a reduced flow limit has to be considered.
D3FB*0 D3FB*3
Code W5
11 + PE acc. to EN 175201-804
D3FB*C
D3FB*E D3FB*K
Surface finish
NBR
4x M6x40 13.2 Nm
BK385 SK-D3FB
ISO 4762-12.9 ±15 %
D3FB*C OBE
Surface finish
NBR
4x M6x40 13.2 Nm
BK385 SK-D3FB
ISO 4762-12.9 ±15 %
CANopen-Profile
CANopen Application Layer and Communication Layer
CiA DS - 301 Version 4.01
D1FB*C*0
M12 female connection
Baud rate switch Spool/sleeve design
Parametrizing connection
Supply voltage
connection
D3FB*C*3
Spool/body design
Manual override
D1FB
D 1 F B 0 N U 0
Directional Size Proportional Standard Spool Spool Seals NBR Communication Options Design Design
control DIN NG06 control dynamics type position (other seal interface series
valve CETOP 03 standard compounds CANopen (not required
on request) DSP 408, 6+PE, for ordering)
NFPA D03 repeatability
1xM12 male
1xM12 female
D3FB
D 3 F B 0 N U 0
Directional Size Proportional Standard Spool Spool Seals NBR Communication Options Design Design
control DIN NG10 control dynamics type position (other seal interface series
valve CETOP 05 standard compounds CANopen (not required
on request) DSP 408, 6+PE, for ordering)
NFPA D05 repeatability
1xM12 male
1xM12 female
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Size NG06/CETOP 03/NFPA D03 NG10/CETOP 05/NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight [kg] 2.5 7
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 210 3
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -25...+60
Viscosity permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
D1FB*0 D1FB*3 D3FB*0/3
Nominal flow
at ∆p=5 bar per control edge 2) [l/min] 6 / 12 / 20 10 / 20 / 30 40 / 60 / 80
Leakage at 100 bar [ml/min] <50 <60 <100
Opening point [%] set to 10 commande signal (see flow characteristics)
Static / Dynamic
Step response at 100 % step [ms] 30 30 40
Hysteresis [%] <4 <6 <5
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple DC [V] 18...30, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0 3.0
Pre fusing medium lag [A] 2.5 4.0
EMC EN 61000-6-2, EN 61000-6-4
Connection supply voltage 6 + PE acc. to EN 175201-804
1 x Male M12x1: 5p
Connection CANopen 1 x Female M12x1: 5p
acc. to IEC61076-2-101
Wiring supply voltage min. [mm2] 3 x 1.0 (AWG16) overall braid shield
Wiring length supply voltage max. [m] 50
Wiring CANopen acc. to CiA DS-301 Version 4 / Twisted pair cable acc. to ISO11898
CANopen
Profiles ommunication Layer CIA DS - 301 version 2
C
Device Profile in accordance with CIA DS - 408 Version 1.5.2
Layer Setting Service (LSS) CIA DS - 305 Version 2
Functionality CANopen slave
One PDO (Receive)
One PDO (Transmit)
One SDO (not useable for valve parameterizing)
Emergency object
Sync object
Node guarding
Life guarding
Heartbeat time (producer/consumer)
Minimum boot - up
Node - ID - adjustment by DIP switch and LSS
Baud Rate - adjustment by DIP switch and LSS
Parameterization
Interface RS 232, parametrizing cable order code 40982923
Interface program ProPxD (see www.parker.com/propxd)
Min [%] 0...50
Adjustment ranges Max [%] 50...100
Ramp [s] 0...32.5
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
Flow rate for different ∆p per control edge: Qx = QNom. ·
2) ∆px
∆pNom.
D_FB CANopen UK.indd RH 17.04.2015
Flow limit
at 25 %, 50 %, 75 % and 100 % command signal (sym-
metric flow). At asymmetric flow a lower flow limit has to
be considered.
D1FB*0 D1FB*3
Spool type E01H Spool type E01K
Flow limit
at 25 %, 50 %, 75 % and 100 % command signal (sym-
metric flow).
At asymmetric flow a lower flow limit has to be considered.
D3FB*0 D3FB*3
CANopen connection
CAN in: M12, 5 pole male terminals. CAN out: M12, 5 pole female terminals.
Pin 1: CAN_SHLD Pin 1: CAN_SHLD
Pin 2: nc Pin 2: nc
Pin 3: CAN_GND Pin 3: CAN_GND
Pin 4: CAN_H Pin 4: CAN_H
Pin 5: CAN_L Pin 5: CAN_L
3 …
61 ON OFF ON ON ON ON
62 OFF ON ON ON ON ON
63 ON ON ON ON ON ON
1 2 3 4 5 6
value
D1FB*C
161.5
3
Ø9.5
22
P
Ø5.5
46
A B
T
72.5 17
222
D1FB*E
161.5
Ø9.5
22
P
Ø5.5
P
46
A B
T
72.5 17
158
Surface finish
NBR
4x M5x30 7.6 Nm
BK375 SK-D1FB
ISO 4762-12.9 ±15%
D3FB*C
D3FB*E
Surface finish
NBR
4x M6x40 13.2 Nm
BK385 SK-D3FB
ISO 4762-12.9 ±15%
vironmental conditions.
The nominal values are factory set. The cable connection A B A B
P T
D*1FB for external electronics P T
Parametrizing connection
Main connector
(always on B-side of main stage)
Manual
override
A B
a b
0
a b
P X Y T
a b
0
a b
T A P B 3
P X Y T
A B
a
Hybrid valve D*1FBZ b
B A
0
a b
T A P B
P X Y T
A B A B A B
T P
T P T P
D*1FB
D 1 F B
Directional NG06 Dynamics Flow Pilot con- Solenoid Valve
control pilot standard nection description options
valve (other voltage
Size Proportional Function Spool Seal on request) Electronic Design
control position options series
(not required
for ordering)
3 Code
3
Nominal size
NG10 / CETOP 05
Code Valve options
Standard for
0
4 NG16 / CETOP 07 spool type B, E, R
9 1) NG25 / CETOP 08 89)10)11) Monitor switch
11 NG32 / CETOP 10 Hybrid valve 24 V
L 8) normally closed
for spool type Z
QB = QA /2
B31 R31 Z31 Code Seal
N NBR
QB = QA /2
V FPM
B32 R32 Z32
E 5)
1)
With enlarged connections Ø 32 mm.
2)
For regenerative and hybrid function at D31FB (NG10) please refer solutions with sandwich - K 5)
and adaptor plates "A10-1664 / A10-1665L / H10-1662 / H10-1666L" in chapter 12.
A B A B
D*1FB OBE
D 1 F B
Directional NG06 Onboard Flow Pilot con- Command Valve
control pilot electronics nection signal options
valve
Size Proportional Function Spool Seal Option Design
control position series
(not required
for ordering)
Code
3
Nominal size
NG10 / CETOP 05
Code Valve options
Standard for
3
0
4 NG16 / CETOP 07 spool type B, E, R
9 1) NG25 / CETOP 08 811)12)13) Monitor switch
11 NG32 / CETOP 10 Hybrid valve 24V
L 10) normally closed
for spool type Z
Regenerative
Standard Hybrid function 2) 3) Command Connec-
function 2) Code Function
signal 7) tion 6)
Code Spool type Code Spool type Code Spool type
F0 9) 0...±10 V 0...+10 V > P-B 6 + PE
Overlap Overlap Overlap
G0 8) 0...±20 mA 0...+20 mA > P-B 6 + PE
E01 M0 8) 9) 0...±10 V 0...+10 V > P-A 6 + PE
S0 4...20 mA 12...20 mA > P-A 6 + PE
E02 0...±10 V 0...+10 V > P-A
W5 8) 9) 11 + PE
4...20 mA 12...20 mA > P-A
QB = QA /2
B31 R31 Z31
Code Seal
QB = QA /2
N NBR
B32 R32 Z32
V FPM
Flow [l/min]
Code Inlet Drain
Code at Dp = 5 bar per metering edge
1 Internal External
D31 D41 D91 D111
B – 100 4) 5) – – 2 External External
C 75 5) 130 4) 5) – – 4 Internal Internal
D 90 5) – – – 5 External Internal
E 120 – 250 4) 5) –
F – 200 - –
H – – 400 –
L – – – 1000 Code Design
General
Design Pilot operated DC valve
Actuation Proportional solenoid
Size NG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10)
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 75
Weight (OBE) [kg] 8.6 (9.3) 11.9 (12.6) 20.4 (21.1) 68 (68.7)
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
3 Hydraulic
15 Shock acc. IEC 68-2-27
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
Flow rate for different ∆p per control edge:
2)
Qx = QNom. · ∆px
∆pNom.
1)
Flow direction depending on ordering code.
1 + US 19.2...28.8 V
2 Out B: normally open
3 0V
4 Out A: normally closed
Signal Output A (pin 4) Output B (pin 2) The neutral position is monitored. The signal changes
neutral closed closed after less than 10 % of the spool stroke.
open closed
closed open
Please order female connector M12x1 separately (see accessories, female connector M12x1 (order no.: 5004109).
1)
Only guaranted with screened cable and female connector
Code W5
11 + PE acc. to EN 175201-804
3 D31FBB/E D31FBR
C M6 DIN906
B 1/16"NPTF
C 1/16"NPTF
B 1/16 NPTF
C 1/16"NPTF
P T
(drawn offset) (drawn offset)
D31FB
Regenerative and hybrid function with additional plate "H10-1666L / H10-1662 / A10-1664 / A10-1665L", see chapter 12.
Surface finish
D41FB
Surface finish
2x M6x55
13.2 Nm ±15 % NBR: SK-D41FB
BK320 4x M10x60
63 Nm ±15 % FPM: SK-D41FB-V
ISO 4762-12.9
D91FB
Surface finish
D111FB
Surface finish
B A
222
3
D31FB OBE
Regenerative and hybrid function with additional plate "H10-1666L / H10-1662 / A10-1664 / A10-1665L", see chapter 12.
Surface finish
D41FB OBE
Surface finish
2x M6x55
13.2 Nm ±15 % NBR: SK-D41FB
BK320 4x M10x60
63 Nm ±15 % FPM: SK-D41FB-V
ISO 4762-12.9
D91FB OBE
Surface finish
D111FB OBE
Surface finish
Function K
D1FV*3 OBE
Parametrizing connection
Main connection
(always on A-side)
Manual override
D1FV
D 1 F V E02 0 K 3
Proportional Size Proportional Spool Pressure Control Seals Solenoid Connector Spool/ Design
pressure DIN NG06 control type range function 12 V / 2.2 A body series
reducing CETOP 03 design (not required
valve NFPA D03 for ordering)
C Code Seals
N NBR
V FPM
E
D 1 F V E02 0 3
Proportional Size Proportional Spool Pressure Control Seals Input Electronic Spool/ Design
pressure DIN NG06 control type range function signal attachment body series
reducing CETOP 03 design (not required
valve NFPA D03 for ordering)
K
Code Seals
N NBR
V FPM
General
Design Direct operated proportional pressure reducing valve
Actuation Proportional solenoid
Size NG06/CETOP 03/NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight (OBE) [kg] 2.2 (2.9)
3
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 185
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524...535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Max. flow [l/min] 10
Min. primary pressure [bar] 30 at 25 pressure range, 50 at 45 pressure range
Static / Dynamic
Hysteresis [%] <4
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics (D1FV)
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 150 °C possible
Standard (as per EN175301-803) IP65 in accordance with EN60529 (with correctly mounted
Protection class
plug-in connector); DT04-2P “Deutsch“ IP69K (with correctly mounted plug-in connector)
Supply voltage [V] 12
Current consumption [A] 2.2
Resistance [Ohm] 4.4
Connector as per EN 175301-803 (code W), DT04-2P “Deutsch“ connector (code J).
Solenoid connection
Solenoid identification as per ISO 9461.
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield (code W), "Deutsch" connector DP4 2 Pin (code J)
Wiring length max. [m] 50 recommended
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Flow characteristics
Code W5
11 + PE acc. to EN 175201-804
D1FV*C
15
85
Ø9.5
22
P
3
Ø5.5
46
A B
T
72.5 17
222
D1FV*E D1FV*K
15
85
Ø9.5
~53
22
P
Ø5.5
P
46
A B
T
72.5 17
158
Ø9.5
71.3
22
P
Ø5.5
P
46
A B
T
72.5 17
222
Surface finish
NBR
4x M5x30 7.6 Nm
BK375 SK-D1FB
ISO 4762-12.9 ±15 %
D1FV*C OBE
125
Ø9.5
22
P
Ø5.5
46
A B
T
72.5 17
222
Ø9.5
22
P
Ø5.5
P
46
A B
T
72.5 17
158
Surface finish
NBR
4x M5x30 7.6 Nm
BK375 SK-D1FB
ISO 4762-12.9 ±15 %
Features
• Progressive flow characteristics for sensitive adjust-
ment
• Low hysteresis
• High dynamics
• High flow capacity
• Compact dimensions
Manual override
D 1 F C C 9 3
Direct Size Propor- High Spool Spool Drain port Y Seal Command Electronic Spool/ Design
Operated DIN NG06 tional dynamics type position plugged 1) signal option body series
DC Valve CETOP 03 control design (not required
NFPA D03 for ordering)
2)
Please order connector separately, see chapter 3 accessories.
General
Design Direct operated proportional DC valve with position feedback
Actuation Proportional solenoid
Size NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight [kg] 3.4
10 Sinus 5...2000 Hz acc. IEC 68-2-6
√
Flow rate for different ∆p per control edge:
2)
Qx = QNom. · ∆px
∆pNom.
Flow characteristics
(set to opening point 10 %) at ∆p = 5 bar per metering edge
Spool type E01/02
100
50
25
3
0
-100 -80 -60 -40 -20 0 20 40 60 80 100
Command signal [%]
Functional limits
25 %, 50 %, 75 % and 100 % command signal (symmetric flow).
At asymmetric flow a reduced flow limit has to be considered.
Spool type E01K
Code 0 Code 5
6 + PE acc. to EN 175201-804 11 + PE acc. to EN 175201-804
Parametrizing cable
3 m length
Item no.: 40982923
Parametrizing
interface
0
command E
0...±10 V µC
3 0...±20 mA
4...12...20 mA
D
diagnostic F
spool stroke I
0...±10 V C
0
G A B
supply
PE voltage
18...30 V=
Code 7
6 + PE acc. to EN 175201-804 + enable
Parametrizing cable
3 m length
Item no.: 40982923 enable
+5...30 V
C
Parametrizing
interface
0
command E
0...±10 V µC
0...±20 mA D
4...12...20 mA
diagnostic
spool stroke F I
0...±10 V
0
G A B
supply
PE voltage
18...30 V=
Port Y plugged
Surface finish
NBR
4x M5x30 7.6 Nm NBR: SK-D1FC
BK375
ISO 4762-12.9 ±15 % FPM: SK-D1FC-V
Features
• Progressive flow characteristics for sensitive adjust-
ment
• Low hysteresis
• High dynamics
• High flow capacity
• Compact dimensions
Manual override
A B
D 3 F C C 9 3
Direct Size Propor- High Spool Spool Drain port Y Seal Command Electronic Spool/ Design
Operated DIN NG10 tional dynamics type position plugged 1) signal option body series
DC Valve CETOP 05 control design (not required
NFPA D05 for ordering)
General
Design Direct operated proportional DC valve with position feedback
Actuation Proportional solenoid
Size NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight [kg] 7.7
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27 3
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350, port T max. 35; 210 (external drain); port Y max. 35
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow
35 / 55 / 75
at ∆p=5 bar per control edge 2) [l/min]
Leakage at 100 bar [ml/min] <100
Opening point [%] set to 10 command signal (see flow characteristics)
Static / Dynamic
Step response at 100 % step [ms] 40
Hysteresis [%] <0.1
Temperature drift [%/K] <0.01
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple DC [V] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre fusing medium lag [A] 4.0
Command Code B voltage [V] +10...0...-10, ripple < 0.01% eff., surge free, 0...+10 V P->A
impedance [kOhm] 100
Code S current [mA] 4...12...20, ripple < 0.01 % eff., surge free, 12...20 mA P–>A
< 3.6 mA = enable off, > 3.8 mA = enable on (according to NAMUR NE43)
impedance [Ohm] 200
Code E current [V] +20...0...-20, ripple < 0.01 % eff., surge free, 0...+20 mA P–>A
impedance [Ohm] 200
Differential input max. [V]
Code 0/7 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code 5 30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0 V (terminal 2)
Min [%] 0...50
Adjustment ranges Max [%] 50...100
Ramp [s] 0...32.5
Parametrizing interface RS232C, parametrizing connection 5pole
Enable signal (code 5/7) [V] 5...30
Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection Code 0/7 6 + PE acc. to EN 175201-804
Code 5 11 + PE acc. to EN 175201-804
Wiring min. [mm²] 7 x 1.0 (AWG 16) overall braid shield
Wiring length max. [m] 50
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
Flow rate for different ∆p per control edge:
2)
Qx = QNom. · ∆px
∆pNom.
Flow characteristics
(Electrically set to opening point 10 %) at ∆p = 5 bar per metering edge
Spool type E01/02 Spool type B31/32
100
Flow Q [l% of nominal flow]
Spool type E*
P-B P-A
75
50
3 25
0
-100 -80 -60 -40 -20 0 20 40 60 80 100
Command signal [%]
Functional limits
25 %, 50 %, 75 % and 100 % command signal (symmetric flow).
At asymmetric flow a reduced flow limit has to be considered.
Spool type E01M Spool type E01U
Code 0 Code 5
6 + PE acc. to EN 175201-804 11 + PE acc. to EN 175201-804
Parametrizing cable
3 m length
Item no.: 40982923
Parametrizing
interface
0
command E
0...±10 V µC
0...±20 mA
4...12...20 mA
D
3
diagnostic F
spool stroke I
0...±10 V C
0
G A B
supply
PE voltage
18...30 V=
Code 7
6 + PE acc. to EN 175201-804 + enable
Parametrizing cable
3 m length
Item no.: 40982923 enable
+5...30 V
C
Parametrizing
interface
0
command E
0...±10 V µC
0...±20 mA D
4...12...20 mA
diagnostic
spool stroke F I
0...±10 V
0
G A B
supply
PE voltage
18...30 V=
Port Y plugged
Surface finish
NBR
4x M6x40 13.2 Nm NBR: SK-D3FC
BK385
ISO 4762-12.9 ±15 % FPM: SK-D3FC-V
Features
• Progressive flow characteristics for sensitive adjust-
ment A-regeneration D*1FCR Hybrid D*1FCZ
• Low hysteresis
• High dynamics
• High flow capacity
• Centre position monitoring optional
• Energy saving A-regeneration optional
• Switchable hybrid version optional
D41FC
Manual
override
A B
T A P B
3
Hybrid valve D*1FCZ
A B A B A B
T P
T P T P
D 1 F C C
Directional NG06 Integrated Flow Pilot Command Valve
control pilot electronics connection signal option
valve with position
feedback
Size Proportional Function Spool Seal Electronic Design
control position option series
on power (not required
down for ordering)
3
Code Nominal size Code Valve option
3 NG10 / CETOP 05 Standard for
0
4 NG16 / CETOP 07 spool type B, E R
9 1) NG25 / CETOP 08 8 6)7)8)
Monitor switch
11 NG32 / CETOP 10 Hybrid valve 24V
L 5) normally closed
for spool type Z
Regenerative
Standard Hybrid function 2) 3) Code Electronic option 4)
function 2)
Code Spool type Code Spool type Code Spool type 0 6+PE acc. EN175201-804
Overlap Overlap Overlap 5 11+PE acc. EN175201-804
6+PE + enable
7
E01 acc. EN175201-804
E02 Command
Code Function
signal
QB = QA /2
R31 Z31 0...+10 V
B31 B 0...±10 V
P -> B
0...+20 mA
QB = QA /2 E 0...±20 mA
P -> B
B32 R32 Z32
0...+10 V
K 0...±10 V
P -> A
12...20 mA
S 4...20 mA
P -> A
Flow [l/min]
Code at Dp = 5 bar per metering edge Code Seal
D31 D41 D91 D111 N NBR
D 90 — — —
V FPM
E 120 — — —
F — 200 — —
H — — 450 — Code Inlet Drain
L — — — 1000 1 Internal External
2 External External
4 Internal Internal
5 External Internal
Parametrizing cable OBE ® RS232, item no. 40982923
1)
With enlarged connections Ø 32 mm.
2)
For regenerative and hybrid function at D31FC (NG10) please refer solutions with sandwich- and adaptor plates
"A10-1664 / A10-1665L / H10-1662 / H10-1666L" in chapter 12.
A B A B
General
Design Pilot operated DC valve
Actuation Proportional solenoid
Size NG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10)
D31 D41 D91 D111
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 75
Weight [kg] 9.0 12.5 21.0 68.5
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27 3
Hydraulic
[bar] Pilot drain internal: P, A, B, X 350; T, Y 210
Max. operating pressure
[bar] Pilot drain external: P, A, B, T, X 350; Y 210
Fluid Hydraulic oil according to DIN 51524...535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow
at Dp=5 bar per control edge 2) [l/min] 90 / 120 200 450 1000
Leakage at 100 bar, main stage [ml/min] 200 200 600 1000
pilot stage [ml/min] <100
Opening point [%] set to 10 command signal (see flow characteristics)
Pilot supply pressure [bar] 20 - 350
Pilot flow, step response [l/min] 2.9 4.1 6.7 15
Static / Dynamic
Step response at 100 % step 3) [ms] 35 37 66 120
Hysteresis [%] ≤ 0.1
Temperature drift [%/K] < 0.005
Sensitivity [%] ≤ 0.05
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
Flow rate for different ∆p per control edge: Qx = QNom. ·
2)
∆px
∆pNom.
Measured with load (210 bar pressure drop / two control edges)
3)
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple DC [V] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0
Pre fusing medium lag [A] 2.5
Command signal
Code K (B) Voltage [V] 10...0...-10, ripple <0.01 % eff., surge free, 0...+10 V P—>A (P—>B)
Impedance [kOhm] 100
Code E Current [mA] 20...0...-20, ripple <0.01 % eff., surge free, 0...+20 mA P—>B
Impedance [Ohm] <250
3
Code S Current [mA] 4...12...20, ripple <0.01 % eff., surge free, 12...20 mA P—>A
< 3.6 mA = enable off, > 3.8 mA = enable on acc. to NAMUR NE43
Impedance [Ohm] <250
Differential input max. [V]
Code 0/7 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0 V (terminal B)
Code 5 30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0 V (terminal 2)
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, parametrizing connection 5pole
Enable signal (code 5/7) [V] 5...30
Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection Code 0/7 6 + PE acc. to EN 175201-804
Code 5 11 + PE acc. to EN 175201-804
Wiring min. [mm²] 7 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
Electrical characteristics hybrid option
Duty ratio [%] 100
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage [V] 24
Tolerance supply voltage [%] ±10
Current consumption [A] 1.21
Power consumption [W] 29
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Flow characteristics
(set to opening point 10 %)
at ∆p = 5 bar per metering edge
D91FC D111FC
Spool type E01, E02, B31, B32 Spool type E01, E02, B31, B32
D91FC D111FC
Spool type R31, R32, Z31, Z32 spool type R/Z* on request
1)
With 2 tank ports.
3 Protection
CE conform
IP65 acc. EN 60529
EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6 1) / ENV 50140 / ENV 50204
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
1 + US 19.2...28.8 V
2 Output B (normally closed)
3 0V
4 Output A (normally closed)
Signal Output A (pin 4) Output B (pin 2) The neutral position is monitored. The signal changes
neutral closed closed after less than 10 % of the spool stroke.
Please order female connector M12x1 separately (see ac-
open closed
cessories, female connector M12x1 (order no.: 5004109).
closed open
1)
Only guaranted with screened cable and female connector
3 D31FCB/E D31FCR
C M6 DIN906
B 1/16"NPTF
C 1/16"NPTF
B 1/16 NPTF
C 1/16"NPTF
P T
(drawn offset) (drawn offset)
D31FC
Regenerative and hybrid function with additional plate "H10-1666L / H10-1662 / A10-1664 / A10-1665L", see chapter 12.
Surface finish
D41FC
Surface finish
2x M6x55
13.2 Nm ±15 % NBR: SK-D41FC
BK320 4x M10x60
63 Nm ±15 % FPM: SK-D41FC-V
ISO 4762-12.9
D91FC
Surface finish
D111FC
Surface finish
Introduction
The new proportional valves with position feedback series
D*FC (direct operated) and D*1FC (pilot operated) with
EtherCAT interface fulfill the requirements of modern
communication between valve and main control. Due to
high data transmission speed and short cycle times, also
demanding control functions can be realized within the
fieldbus system.
The valve is actuated and monitored by the EtherCAT
interface. Actual value (spool position), temperature, op-
erating hours and different error messages are available
D1FC with EtherCAT 3
as diagnostic signals. The valve parameters are factory
set and can be adapted with the Parker ProPxD software
via the parametrizing interface.
Features EtherCAT interface
In addition to the fieldbus communication, the valves pro-
• EtherCAT interface, 2x M12x1 connector 4-Pin (Ether-
vide the range of functions of the standard version includ-
CAT In and EtherCAT Out)
ing analogue command signal and diagnostic spare
stroke. Thus they can be operated independent of the • Progressive flow characteristics for sensitive adjust-
fieldbus control, particularly during commissioning and ment
maintenance. • Low hysteresis
The option with EtherCAT is available for the series: • High dynamics
• D1FC, D3FC • High flow capacity
• D31FC, D41FC, D91FC, D111FC • Onboard electronics
Technical Data
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple [V] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0 (D1FC, D*1FC), 3.5 (D3FC)
Pre fusing medium lag [A] 2.5 (D1FC, D*1FC), 4.0 (D3FC)
Differential input [V] 30 for terminal D and E against PE (terminal G)
Diagnostic signal [V] +10...0...-10 / +12.5 error detection
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. to EN 175201-804
EtherCAT interface 2 x socket M12x1: 5p acc. to IEC61076-2-101
Wiring min. [mm²] 3 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
Wiring EtherCAT acc. to CiA DS-301 Version 4 / Twisted pair cable acc. to ISO11898
Communication Layer IEC 61158-x-12, 301 Version 4
EtherCAT profiles Device Profile in accordance with CIA DS - 408 Version 1.5.2
CANopen over EtherCAT (object dictionary)
One PDO (Receive)
Functionality One PDO (Transmit)
BUS-cycle time down to 0.250 mSec.
Parameterization
Interface RS 232, parametrizing cable order code 40982923
Interface program ProPxD (see www.parker.com/propxd)
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [%] 0...32.5
D F C C 9 N00
DC Size Proportional High Spool Spool Drain port Y Seals EtherCAT Design
valve control dynamics type position (plugged) interface series
on power (not required
down for ordering)
Code Size
3 1
3
NG06 / CETOP 03
NG10 / CETOP 05
See ordering code for valve series without EtherCAT
D 1 F C C N00
DC Size NG06 Proportional Integrated Function Flow Spool Pilot Seals EtherCAT Design
valve pilot control electronics position connection interface series
valve with position on power (not required
feedback down for ordering)
Code Size
See ordering code for valve series without EtherCAT
3 NG10 / CETOP 05
4 NG16 / CETOP 07
9 NG25 / CETOP 08
11 NG32 / CETOP 10
Features
• Real servovalve dynamics
(-3 dB / 350 Hz at ±5 % input signal)
• No flow limit up to 350 bar pressure drop through the
valve
• Max. tank pressure 350 bar
(with external drain port y)
• High flow
• Defined spool positioning at power-down - optional
P-A/B-T or P-B/A-T or center position
(for overlapped spools)
• Onboard electronics
D 1 F P 9 0
Directional Size Proportional VCD Spool Spool Y-port Seals Command Acces- Spool/ Design
control DIN NG06 control type position (plugged) 5) signal sories sleeve series
valve CETOP 03 on power design (not required
NFPA D03 down 1) for ordering)
3
per metering edge
11 + PE
Zerolap 5
acc. EN175201-804
E50B 3
E50C 6 7 6 + PE + Enable
E50F 12
E50G 16
E50H 25 Code Signal Function
E50M 40 B +/- 10 V 0...+10 V -> P-A
B60C 6/3
E +/- 20 mA 0...+20 mA -> P-A
B60F QB = QA /2 12 / 6
B60G 16 / 8 S 4...20 mA 12...20 mA -> P-A
B60H 25 / 12.5
B60M 40 / 20
Underlap Code Seals
E55B 3 N NBR
E55C 6
E55F 12 V FPM
E55G 16 H for HFC fluid
E55H 25
E55M 40
Overlap Spool position
E01B 3 Code
at power down
E01C 6
E01F 12
E01G 16 A 2)
E01H 25
E01M 40
B31C 6/3
B31F QB = QA /2 12 / 6 B 2)
B31G 16 / 8
B31H 25 / 12.5
B31M 40 / 20
E02B 3 C 3)
E02C 6
E02F 12
E02G 16 A B
E02H 25
H 4) a 0 b
E02M 40
B32C 6/3 P T
B32F QB = QA /2 12 / 6 A B
B32G 16 / 8
B32H 25 / 12.5 J 4) a 0 b
B32M 40 / 20 P T
Note:
Adapter plate for ISO 4401 to ISO 10372 size 04, Ordering code HAP04WV06-1661
Please order connector separately, see chapter 3 accessories.
Parametrizing cable OBE -> RS232, item no. 40982923
1)
On power down the spool moves in a defined position. This cannot be guaranteed in case of single flow path on the control edge A – T resp.
B – T with pressure drops above 120 bar or contamination in the hydraulic fluid.
2)
Approx. 10 % opening, only zero lapped spools and underlap spools.
3)
Only for overlapped spools.
4)
Not for flow code M (40 l/min).
5)
Plug in the Y-port needs to be removed at tank pressure >35 bar.
General
Design Direct operated servo proportional DC valve
Actuation VCD® actuator
Size NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 150
Weight [kg] 5.0
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
3 Hydraulic
15 Shock acc. IEC 68-2-27
Max. operating pressure [bar] Ports P, A, B 350, port T 35 for internal drain, 350 for external drain, port Y 35 2)
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt]/mm2/s] 20...400
recommended [cSt]/mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow
at ∆p=35 bar per control edge 3) [l/min] 3 / 6 / 12 / 16 / 25 / 40
Flow maximum [l/min] 90 (at ∆p=350 bar over two control edges)
Leakage at 100 bar [ml/min] <400 (zerolap spool); <50 (overlap spool)
Opening point [%] set to 23 commande signal (see flow characteristics)
Static / Dynamic
Step response at 100 % step 4) [ms] <3.5
Frequency response
(±5 % signal) 4) [Hz] 350 (amplitude ratio -3 dB), 350 (phase lag -90°)
Hysteresis [%] <0.05
Sensitivity [%] <0.03
Temperature drift [%/K] <0.025
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple [V] DC 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 medium lag
Input signal
Code B Voltage [V]
10...0...-10, ripple <0.01 % eff., surge free, 0...+10 V P->A
Impedance [kOhm] 100
Code E Current [mA] 20...0...-20, ripple <0.01 % eff., surge free, 0...+20 mA P->A
Impedance [Ohm] 250
Code S Current [mA] 4...12...20, ripple <0.01 % eff., surge free, 12...20 mA P->A
<3.6 mA = disable, >3.8 mA = according to NAMUR NE43
Impedance [Ohm] 250
Differential input max.
Code 0 [V] 30 for terminal D and E against PE (terminal G)
Code 5 [V] 30 for terminal 4 and 5 against PE (terminal W )
Code 7 [V] 30 for terminal D and E against PE (terminal G)
Enable signal (only code 5/7) [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Code 0/7 6 + PE acc. EN 175201-804
Electrical connection
Code 5 11 + PE acc. EN 175201-804
Wiring min. Code 0/7 [mm²] 7x1.0 (AWG 16) overall braid shield
Code 5 [mm²] 8x1.0 (AWG 16) overall braid shield
Wiring length max. [m] 50
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
2)
For applications with pT>35 bar (max. 350 bar) the Y-port has to be connected and the plug in the Y-port has to be removed.
√
3)
Flow rate for different ∆p per control edge: Qx = QNom. · ∆px
∆pNom.
4)
Measured with load (100 bar pressure drop/two control edges).
Flow curves
(Overlapped spool set to opening point 23 %)
at Dp = 35 bar per metering edge
Spool type E01/E50 Spool type B31/B60
3
Pressure gain Functional limits
at 25 %, 50 %, 75 % and 100 % command signal
Spool type E01M/E50M
Frequency response
±5 % command signal
±90 % command signal
Code 0 Code 5
6 + PE 11 + PE
Code 7
6 + PE + Enable
Surface finish
NBR: SK-D1FP
4x M5x30 7.6 Nm
BK375 FPM: SK-D1FP-V
ISO 4762-12.9 ±15 %
HFC: SK-D1FP-H
Features
3
• Real servovalve dynamics
(-3 dB / 350 Hz at ±5 % input signal)
• Max. tank pressure 250 bar
(with external drain port Y)
• Defined spool positioning at power-down - optional
P-A/B-T or P-B/A-T or center position
(for overlapped spools)
• Onboard electronics
• Spool / sleeve design
D 3 F P 9 0
Direct. Size Proportional VCD Spool Spool Y-port Seals Command Acces- Spool/ Design
control DIN NG10 control type position (plugged) 4) signal sories sleeve series
valve CETOP 05 on power design (not required
NFPA D05 down 1) for ordering)
3
per metering edge
11 + PE
Zerolap 5
acc. EN175201-804
E50P 50 7 6 + PE + Enable
E50Y 100
QB = QA /2 Code Signal Function
B60P 50 B +/- 10 V 0...+10 V -> P-A
E +/- 20 mA 0...+20 mA -> P-A
QB = QA /2
B60Y 100 S 4...20 mA 12...20 mA -> P-A
C 3)
For regenerative and hybrid function at D31FB (NG10) please refer solutions with sandwich- and adaptor plates
"A10-1664 / A10-1665L / H10-1662 / H10-1666L" in chapter 12.
Please order connector separately, see chapter 3 accessories.
Parametrizing cable OBE -> RS232, item no. 40982923
1) On power down the spool moves in a defined position. This cannot be guaranteed in case of single flow path on the control edge A – T resp.
B – T with pressure drops above 120 bar or contamination in the hydraulic fluid.
2) Approx. 10 % opening, only zerolapped spools and underlapped spools.
3) Only for overlapped spools.
4) Plug in the Y-port needs to be removed at tank pressure >35 bar.
General
Design Direct operated servo proportional DC valve
Actuation VCD® actuator
Size NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 150
Weight [kg] 6.5
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
Hydraulic
15 Shock acc. IEC 68-2-27
3
Max. operating pressure [bar] Ports P, A, B 350, port T 35 for internal drain, 250 for external drain, port Y 35 2)
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow nominal
at ∆p=35 bar per control edge 3) [l/min] 50 / 100
Flow maximum [l/min] 150
Leakage at 100 bar [ml/min] <400 (zerolap spool); <100 (overlap spool)
Opening point [%] set to 19 command signal (see flow characteristics)
Static / Dynamic
Step response at 100 % step 4) [ms] <6
Frequency response (±5 % signal) 4) [Hz] 200 (amplitude ratio -3 dB), 200 (phase lag -90°)
Hysteresis [%] <0.05
Sensitivity [%] <0.03
Temperature drift [%/K] <0.025
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple [V] 22 ... 30, electric shut-off at < 19, ripple <5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 medium lag
Input signal
Code B Voltage [V] 10...0...-10, ripple <0.01 % eff., surge free, 0...+10 V P->A
Impedance [kOhm] 100
Code E Current [mA] 20...0...-20, ripple <0.01 % eff., surge free, 0...+20 mA P->A
Impedance [Ohm] 250
Code S Current [mA] 4...12...20, ripple <0.01 % eff., surge free, 12...20 mA P->A
<3.6 mA = disable, >3.8 mA = according to NAMUR NE43
Impedance [Ohm] 250
Differential input max.
Code 0 [V] 30 for terminal D and E against PE (terminal G)
Code 5 [V] 30 for terminal 4 and 5 against PE (terminal W )
Code 7 [V] 30 for terminal D and E against PE (terminal G)
Enable signal (only code 5/7) [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Code 0/7 6 + PE acc. EN 175201-804
Electrical connection
Code 5 11 + PE acc. EN 175201-804
Wiring min. Code 0/7 [mm²] 7 x 1.0 (AWG 16) overall braid shield
Code 5 [mm²] 8 x 1.0 (AWG 16) overall braid shield
Wiring length max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
2) For applications with pT>35 bar (max. 250 bar) the Y-port has to be connected and the plug in the Y-port has to be removed.
√
3) Flow rate for different ∆p per control edge: Qx = QNom. · ∆px
∆pNom.
4) Measured with load (100 bar pressure drop/two control edges).
Flow curves
(Overlapped spool set to opening point 19 %)
at Dp = 35 bar per metering edge
Spool type E50/E55, E01/E02 Spool type B31/B32, B60
1) When exceeding the functional limits, for a period of time the valve will go into fail safe and power supply needs to be switched off/on to re-
enable the valve.
Code 0 Code 5
6 + PE 11 + PE
Code 7
6 + PE + Enable
Surface finish
NBR: SK-D3FP
4xM6x40 13.2 Nm
BK385 FPM: SK-D3FP-V
ISO 4762-12.9 ±15 %
HFC: SK-D3FP-H
Features
3 • Pilot operated with hydraulic follower sleeve
• No flow limit up to 350 bar through the valve
• Defined spool positioning at power-down - optional P-A /
B-T or P-B / A-T or center position (for overlapped spools)
G G
a 0 a 0 b
b
D30FP*3
with hydraulic follower principle
D 30 F P 3
Direct. Size Proportional VCD Spool Spool Pilot Seals Command Acces- Spool/ Design
control DIN NG10 control type position connection signal sories body series
valve CETOP 05 on power design (not required
NFPA D05 down for ordering)
3
per metering edge
11 + PE
Zerolap 5
acc. EN175201-804
E50U 80 7 6 + PE + Enable
QB = QA /2
B60U 80
Code Signal Function
Overlap B +/- 10 V 0...+10 V -> P-A
E +/- 20 mA 0...+20 mA -> P-A
E01U 80
S 4...20 mA 12...20 mA -> P-A
E02U 80
QB = QA /2 Code Seals
B31U 80 N NBR
V FPM
QB = QA /2
H for HFC fluid
B32U 80
A 1)
B 1)
C 2)
General
Design Pilot operated servo proportional DC valve
Actuation VCD® actuator
Size NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position horizontal mounting preferred (other mounting positions after consultation)
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 75
Weight [kg] 6.5
Vibration resistance [g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
3
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 35 for internal drain, 250 for external drain
[bar] Port Y 35 2)
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow nominal at ∆p=5 bar
per control edge 3) [l/min] 80
Flow maximum [l/min] 250
Leakage at 100 bar [ml/min] <1800 (Zerolap spool); <1000 (Overlap spool)
Opening point [%] set to 9 commande signal (see flow characteristics)
Pilot supply pressure [bar] >5 higher than tank pressure (only internal pilot oil supply)
Static / Dynamic
Step response at 100 % step 4) [ms] <7
Frequency response [Hz] 120 (amplitude ratio -3 dB), 120 (phase lag -90°)
(±5 % signal) 4)
Hysteresis [%] <0.05
Sensitivity [%] <0.03
Temperature drift [%/K] <0.025
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple [V] DC 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 medium lag
Input signal
Code B Voltage [V] 10...0...-10, ripple <0.01 % eff., surge free, 0...+10 V P->A
Impedance [kOhm] 100
Code E Current [mA] 20...0...-20, ripple <0.01 % eff., surge free, 0...+20 mA P->A
Impedance [Ohm] 250
Code S Current [mA] 4...12...20, ripple <0.01 % eff., surge free, 12...20 mA P->A
<3.6 mA = disable, >3.8 mA = according to NAMUR NE43
Impedance [Ohm] 250
Differential input max.
Code 0 [V] 30 for terminal D and E against PE (terminal G)
Code 5 [V] 30 for terminal 4 and 5 against PE (terminal W )
Code 7 [V] 30 for terminal D and E against PE (terminal G)
Enable signal (only code 5/7) [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Code 0/7 6 + PE acc. EN 175201-804
Electrical connection
Code 5 11 + PE acc. EN 175201-804
Wiring min. Code 0/7 [mm²] 7 x 1.0 (AWG 18) overall braid shield
Code 5 [mm²] 8 x 1.0 (AWG 18) overall braid shield
Wiring length max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
2) For applications with p >35 bar (max. 250 bar) the Y-port has to be connected and the plug in the Y-port has to be removed.
T
√
3) Flowrate for different ∆p per control edge: Qx = QNom. · ∆px
∆pNom.
4) Measured with load (100 bar pressure drop/two control edges).
Flow curves
(Overlapped spool set to opening point 9 %)
at Dp = 5 bar per metering edge
Spool type E01/02, E50
Pressure gain
Frequency response
±5 % command signal
±25 % command signal
Code 0 Code 5
6 + PE 11 + PE
Code 7
6 + PE + Enable
Surface finish
NBR: SK-D3FP
4xM6x40 13.2 Nm
BK385 FPM: SK-D3FP-V
ISO 4762-12.9 ±15 %
HFC: SK-D3FP-H
A B
G
0
a b
G
0
a b
P X Y T
G
0
a b
3
P X Y T
G
a b
G
0
a b
P X Y T
A B A B A B
T P
T P T P
D 1 F P
Directional Size NG06 Propor- VCD Function Flow Spool Pilot Seals Command Electronic Valve Design
control pilot tional perfor- position connec- signal options option series
valve control mance on power tions (not required
down for ordering)
QB = QA /2 0...+10 V
K 0...±10 V
B32 P -> A
12...20 mA
zerolap zerolap zerolap S 4...20 mA
P -> A
E52 R61
Z61
QB = QA /2 Code Seals
B61 N NBR
V FPM
H for HFC fluid
Flow [l/min]
Code at Dp = 5 bar per metering edge Code Inlet Drain
D31 D41 D81 D91 D111 1 internal external
D 90 — — — — 2 external external
E 120 — — — —
4 internal internal
F — 200 — — —
5 external internal
H — — 400 450 —
L — — — — 1000
Code Spool pos. on power down
Please order connector separately. See chapter 3 accessories.
Parametrizing cable OBE -> RS232, item no. 40982923 A 2)
1)
For enlarged connections Ø 32 mm.
2)
Approx. 10 % opening, only zero lapped spools.
3)
For overlapped spools.
4)
Not for D81FP.
5)
For regenerative and hybrid function at D31FP (NG10) please refer to solutions
B 2)
with sandwich and adaptor plates "A10-1664 / A10-1665L / H10-1662 / H10-
1666L" in chapter 12.
A B A B A B
General
Design Pilot operated servo proportional DC valve
Actuation VCD®-actuator
Size NG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10)
D31 D41 D81 / D91 D111
Mounting Interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 75
Weight [kg] 11.3 14.2 23.5 64.5
10 Sinus 5...2000 Hz acc. IEC 68-2-6
Vibration resistance [g] 30 Random noise 20...2000 Hz acc. IEC 68-2-36
3 Hydraulic
15 Shock acc. IEC 68-2-27
√
∆px
2)
Flow rate for different ∆p per control edge: Qx = QNom. ·
∆pNom.
3)
Measured with load (210 bar pressure drop/two control edges).
3
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Wiring
Code 0, 6 + PE acc. EN 175201-804 Code 5, 11 + PE acc. EN 175201-804
Frequency response
±5 % / ±25 % / ±90 % command signal
Dynamics at 210 bar pilot supply pressure
D31FP D41FP
D81/91FP D111FP
Flow curves
D81/91FP D111FP
Spool type E01/02/52, B31/32/61 Spool type E01/02/52, B31/32/61
Detail:
Standard, regenerative and hybrid flow curves
Overlap spools:
E01,
E02,
[% of nominal flow]
B/R/Z31,
B/R/Z32
Zerolap spools:
E52,
B/R/Z61
Flow Q
0
0 10 20
Command signal [%]
G
Pilot oil 0
Drain a b
Inlet B C
internal external
G
external external a
0
b
internal internal
external internal P B
x y C
T
D31FPB/E D31FPR
3
C M6 DIN906
B 1/16"NPTF
C 1/16"NPTF
B 1/16 NPTF
C 1/16"NPTF
D31FP
Regenerative and hybrid function with additional plate "A10-1664 / A10-1665L / H10-1662 / H10-1666L", see chapter 12.
Surface finish
D41FP
Surface finish
2x M6x55
13.2 Nm ±15 % NBR: SK-D41FP
BK320 4x M10x60
63 Nm ±15 % FPM: SK-D41FP-V
ISO 4762-12.9
D81/91FP
Surface finish
D111FP
Surface finish
Introduction
DFplus valves with EtherCAT interface fulfill the require-
ments of modern communication between valve and main
control. Due to high data transmission speed and short
cycle times, the high dynamics of the DFplus valves can
be also utilized within the fieldbus system.
The valve is actuated and monitored by the EtherCAT
interface. Actual value (spool position), temperature,
operating hours and different error messages are avail-
3 able as diagnostic signals. The valve parameters are
factory set and can be adapted with the Parker ProPxD
D1FP with EtherCAT
The option with EtherCAT is available for the series: Features EtherCAT interface
• D1FP, D3FP • EtherCAT interface, 2x M12x1, connector 4-Pin (Ether-
• D30FP CAT In and EtherCAT Out)
• D31FP, D41FP, D81FP, D91FP, D111FP • High dynamics
as well as for cartridge valves TDP, TEP and TPQ in • High flow capacity
chapter 8. • Onboard electronics
Technical Data
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple [V] 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre fusing [A] 4.0 medium lag
Differential input [V] 30 for terminal D and E against PE (terminal G)
Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. to EN 175201-804
EtherCAT interface 2 x socket M12x1: 5p acc. to IEC61076-2-101
Wiring min. [mm²] 3 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
Wiring EtherCAT acc. to CiA DS-301 Version 4 / Twisted pair cable acc. to ISO11898
Communication Layer IEC 61158-x-12, 301 Version 4
EtherCAT profiles Device Profile in accordance with CIA DS - 408 Version 1.5.2
CANopen over EtherCAT (object dictionary)
One PDO (Receive)
Functionality One PDO (Transmit)
BUS-cycle time down to 0.250 mSec.
Parameterization
Interface RS 232, parametrizing cable order code 40982923
Interface program ProPxD (see www.parker.com/propxd)
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [%] 0...32.5
The EtherCAT option is also available for the cartridge valves in chapter 8, series TDP, TEP and TPQ
Direct operated proportional DC valve
D F P 9 N00
Directional Size Proportional VCD Spool Spool Y-port Seals EtherCAT Design
control control type position (plugged) interface series
valve on power (not required
down for ordering)
Code Size
See ordering code for valve series without EtherCAT
3
1 NG06 / CETOP 03
3 NG10 / CETOP 05
D 30 F P N00
Direct. Size Proportional VCD Spool Spool Pilot Seals EtherCAT Design
control control type position connection interface series
valve on power (not required
down for ordering)
Code Size
See ordering code for valve series without EtherCAT
30 NG10 / CETOP 05
D 1 F P N00
Direct. Size NG06 Proportional VCD Function Flow Spool Pilot Seals EtherCAT Design
control pilot valve control position connection interface series
valve on power (not required
down for ordering)
Code Nenngröße
See ordering code for valve series without EtherCAT
3 NG10 / CETOP 05
4 NG16 / CETOP 07
8 NG25 / CETOP 08
9 NG25 / CETOP 08
11 NG32 / CETOP 10
Solenoid connector
D*FB, D*1FB, D1FV
Description Variation Order no.
EN 175301-803 2+PE PG 9 black B 5001710
EN 175301-803 2+PE PG 9 grey A 5001711
EN 175301-803 2+PE PG 11 black B 5001716
EN 175301-803 2+PE PG 11 grey A 5001717
3
Plug kit DT04-2P “Deutsch“
D1FB, D*1FB, D1FV
Description Order no.
Connector DT04-2P “Deutsch“ 45216087
Central connector
D*FB*0 OBE, D*1FB*0 OBE, D1FV*0 OBE, D*FC*0, D*1FC*0/7, D*FP*0/7, D*1FP*0/7
7/8-20
max. 67 UNEF-2B Description Order no.
EN 175201-804 6 + PE 5004072
Ø28.6
PG13.5
Central connector
D*FB*5 OBE, D*1FB*5 OBE, D1FV*5 OBE, D*FC*5, D*FP*5, D*1FP*5
Access03.INDD RH 17.04.2015
D1FB
Solenoid kits: D1FBS... (Example: AK-D1FBSJW014)
Voltage Connector as per
Voltage Design Design series
code EN 175301-803
9 V / 2.7 A M W 0 14
12 V / 2.2 A K W 3 14
24 V / 0.8 A J W 0 14
24 V / 1.1 A J W 3 14
D3FB
Solenoid kits: D3FBS... (Example: AK-D3FBSKW12)
Voltage Connector as per
Voltage Design series
code EN 175301-803
12 V / 2.95 A K W 12
24 V / 1.5 A J W 12
Access03.INDD RH 17.04.2015
Size 6, mounting pattern to ISO 4401-03-03-0-05 Size 10, mounting pattern to ISO 4401-05-05-0-05
Subplate
Screw-in
Parker Standard 06 10
Direct
Panel
Pilot
DIN / ISO 06 10 25 32
Content04.INDD RH 25.03.2015
Function
• Spool type valve
• Subplate mounting according to ISO 6264
• 5 pressure stages
• 2 adjustment modes
• Gauge port
4
A B
P T
Ordering code
VS A 06 V G
Pressure Pressure Adjustment Nominal FPM Gauge Lock Design
relief stages screw size seals port series
valve with G1/4“ (not required
hexagon for ordering)
socket
Technical data
General
Design Direct operated relief valve spool type
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Interface Subplate mounting according to ISO 6264
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.3
Hydraulic
Max. operating pressure [bar] Port P 350, Port T depressurized
Pressure stages [bar] 25, 64, 160, 210, 350
Nominal flow [l/min] 25
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20…+70
Viscosity permitted [cSt] / [mm²/s] 20…400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
VS UK.indd RH 17.04.2015
4
Pressure stage 64 bar
VS UK.indd RH 17.04.2015
VS UK.indd RH 17.04.2015
Features
• Spool type valve
• Subplate mounting according to ISO 5781
VB*A10
• 5 pressure stages at NG06
• 3 pressure stages at NG10
• 2 adjustment modes
4
VB*A06 VB*A10
VB*A06 VB*A10
A P T
B Y A
Ordering code
VB A V
Pressure Pressure Adjustment Nominal FPM Gauge Lock Design
relief stages screw size seals port series
valve with hexa- (not required
gon socket for ordering)
Code Lock
Code Pressure stages
omit –
025 1) up to 25 bar
Z Cylinder lock
064 up to 64 bar
125 2) up to 125 bar
160 1) up to 160 bar
Code Gauge port
210 up to 210 bar
G 1) G 1/4”
350 1) up to 350 bar
M 2) M18x1.5
VB UK.indd RH 17.04.2015
General
Design Direct operated pressure relief valve, spool type
Nominal size NG06 (CETOP 03 / NFPA D03) NG10 (CETOP 05 / NFPA D05)
Interface Subplate mounting according to ISO 5781
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.3 3.7
Hydraulic
Max. operating pressure [bar] Port P and A 350 Port A and B 350
Port T depressurized Port Y depressurized
Pressure stages [bar] 25, 64, 160, 210, 350 64, 125, 210
Nominal flow [l/min] 25 60
4
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
VB UK.indd RH 17.04.2015
4
Setting pressure max. 160 or 210 bar
VB*10
Setting pressure max. 64 bar Setting pressure max. 210 bar
VB UK.indd RH 17.04.2015
NG06
VB UK.indd RH 17.04.2015
NG10
1)
Deviating from ISO the Y port has Ø 14.7 instead of Ø 4.8.
VB UK.indd RH 17.04.2015
Features
• Subplate mounting acc. to ISO 5781
• Main stage spool type VBY*A06 VBY*A10
• Pilot stage seated type
• 4 pressure stages
4 • 2 adjustment modes:
- screw with hexagon socket
- cylinder lock
VBY*A06 VBY*A10
VBY*A06 VBY*A10
1)
Port B for remote control, otherwise to be blocked.
2)
Port X for remote control, otherwise to be blocked.
Ordering code
VBY
Pressure Pressure Adjustment Nominal Seals Design
relief valve stages size series
(not required
for ordering)
Technical data
General
Design Pilot operated pressure relief valve, spool type
Nominal size NG06 NG10
Interface Subplate mounting according to ISO 5781
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.4 4.5
Hydraulic
Max. operating pressure [bar] P, A 315, B blocked A, B 350, X blocked
External drain port pressure [bar] T 100 Y 100
Pressure stages [bar] 64, 160, 210, 315
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20…400
recommended [cSt] / [mm²/s] 30…80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow [l/min] See p/Q curves
Pilot oil flow [cm³/min] approx. 500 approx. 1000
NG06
NG10
1)
Deviating from ISO the Y port has Ø 14.7 instead of Ø 4.8.
Technical data
General
Design Direct operated relief valve, seated type
Nominal size NG06 NG10
Interface Screw-in mounting
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 0.3 0.45
Hydraulics
Max. operating pressure [bar] Port P 315, Port T depressurized
Pressure stages [bar] 64, 160, 315
Nominal flow [l/min] 40 (NG06), 80 (NG10)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20…+70
Viscosity permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
4
NG06 pressure stage 160 bar NG10 pressure stage 160 bar
NG06 pressure stage 315 bar NG10 pressure stage 315 bar
NG06
SK-EVSAA0613
4
NG10
SK-EVSAA1013
Installation dimensions
Size M D1 D2 D3 D4 D5 L1 L2 L3 L4 L5 L6
NG06 M28 x 1.5 Ø24.8 Ø15 Ø6.8 Ø25 H9
Ø6.8 15 19 30 35 45 65
NG10 M35 x 1.5 Ø31.8 Ø18.5 Ø10 Ø32 H9
Ø10 18 23 35 41 - 46 52 80
Features P
• Seated type valve
• Body variants: Front panel mounting
- front panel mounting
- subplate mounting
T
• 3 pressure stages
4 • 3 adjustment modes:
- hand knob
- acorn nut with lead seal
- cylinder lock
Subplate mounting
R1E02
Y
T P X Pilot operated
pressure relief
valve
A B
Ordering code
R1E02 2 A 1
Pressure Body Pressure Connections Adjust- Design Seals Options
relief valve stages G1/4“ ment series NBR
4
4 1) Cylinder lock
Code Pressure stages
1 up to 105 bar
3 up to 210 bar
5 up to 350 bar
Technical data
General
Design Direct operated relief valve, seated type
Nominal size 1/4’’
Body variants Front panel mounting Subplate mounting
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 2.1 1.0
Hydraulics
Max. operating pressure [bar]Port P 350, Port T depressurized
Pressure stages [bar]105, 210, 350
Fluid temperature [°C]-25...+70
Nominal flow [l/min] 3.8
Fluid Hydraulic oil according to DIN 51524
Minimum setting pressure [bar] 7
Viscosity permitted [cSt] / [mm²/s] 20…400
recommended [cSt] / [mm²/s] 30…80
Filtration ISO 4406 (1999); 18/16/13
6
Inlet pressure
0
1 2 3 4 5 6 7
Flow [l/min]
Ø10.4
Ø7.2
P T
Ø63.5
Ø32
83
.5
82
13
39.7 88.7
140.7 max.
Subplate mounting
143 max.
60.8 closed during
shipment
T
Hand knob
38
28.5
Ø10.5
Ø16.5
144.8
1.6
Acorn nut
with lead seal
P T
31.7
52
Cylinder lock
3.2 20.6
58.7
60.3
181 30
S16-91963-0
Features
• Pilot operated with manual adjustment
• 2 interfaces R6V06 R6V06 with vent valve
- R4V subplate ISO 6264 (DIN 24340 Form D)
with VV01 vent valve
- R6V subplate ISO 6264 (DIN 24340 Form E)
with CETOP 03 vent valve
• 3 pressure stages
4
• 3 adjustment modes:
- hand knob
- acorn nut with lead seal
- cylinder lock
• Remote control via port X
R4V06 with vent valve
Code 09 Code 11
R V 5
Pressure Relief Max. Pressure Pilot oil Seals Modifications
valve function pressure setting range
(350 bar)
Interface Nominal Drain port Adjustment Design Design
size series
(not required
for ordering)
1) R4V only.
2) R6V only.
R V 5
Pressure Relief Max.pressure Pressure Pilot oil Solenoid Seals Modifications
valve function (350 bar) setting range voltage
6
ISO 6264
4
Code Seals
1 NBR
5 FPM
Code Nominal size
03 NG10
Code Design
06 NG25
A R4V
10 NG32
B R6V
1) R4V only.
2) R6V only.
3) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4) Vent valve function code 09 only.
R4V/R6V
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 6264 (DIN 24340)
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight Series R6V [kg] 4.5 5.8 7.8
Series R4V [kg] 2.7 4.5 6.0
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, Port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 250 500 650
4 Fluid
Viscosity, permitted [cSt] / [mm²/s]
Hydraulic oil according to DIN 51524
20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
4
NG32
R6V
L5 30 X1
L3 X3 X2
d4xt4
X5
Hand
knob
Y3
Ød2
Ød1
B1
P T
Y1
X
B2
Ød3xt3
L1 Cylinder lock
X7
4 L2
Ød6
H1
H3
H2
H5
Y
H6
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80 26.9 114 27 88 20.5 25 52 117 141 180 29.5
25 6264-08-13-*-97 100 35 117.5 46.5 91.5 – 25 12 37.9 124.5 141 – 180 36.5
32 6264-10-17-*-97 120 41.3 124.5 51.3 98.5 26.5 13.5 44.3 153 141 180 46.5
NG Surface finish
NBR FPM
10 BK494 4x M12x45 ISO 4762-12.9 108 Nm ±15 % S26-98589-0 S26-98589-5
25 BK366 4x M16x70 ISO 4762-12.9 264 Nm ±15 % S26-96396-0 S26-96396-5
32 BK507 4x M18x75 ISO 4762-12.9 398 Nm ±15 % S26-96392-0 S26-96392-5
Y3
Ød1
Ød2
B1
Y1
X P T
B2
Ød3xt3
L1 X7
L2
15
Hand knob
H1
H4
Ød6
Cylinder
lock
H3
H5
Y
H6
Ød5 L6
L5 30
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80 26.9 203.4 27 88 136.3 25 12 52 117 163.8 180 36.5
25 6264-08-13-*-97 100 35 206.9 46.5 91.5 139.8 25 12 37.9 124.5 163.8 – 180 36.5
32 6264-10-17-*-97 120 41.3 213.9 51.3 98.5 146.8 25 12 44.3 153 163.8 180 36.5
NG Surface finish
NBR FPM
10 BK494 4x M12x45 ISO 4762-12.9 108 Nm ±15 % S26-98589-0 S26-98589-5
25 BK366 4x M16x70 ISO 4762-12.9 264 Nm ±15 % S26-96396-0 S26-96396-5
32 BK507 4x M18x75 ISO 4762-12.9 398 Nm ±15 % S26-96392-0 S26-96392-5
R4V X1
X2
X3
X4 d4xt4
X5 Ød2
Y4
Y
Y5
Ød3xt3
Y3
Ød1
Y2
B1
Y1
A B
B2
Cylinder
lock X
4
Ød2
L1
X6
L2
L5 30
L6
L4 Hand knob
Acorn nut
Ød6 with lead seal
H1
H5
Ød5
H2
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-07-*-97 87.3 33.35 83 21 – – 62.5 – 25 90.8 – 143 181 144.8
25 6264-08-11-*-97 105 39.7 107.5 29 – – 87 – 30.9 123 – 143 181 144.8
32 6264-10-15-*-97 120 48.4 120 30 – – 99.5 – 29.8 143.5 – 143 181 144.8
NG Surface finish
NBR FPM
10 BK505 4x M10x35 ISO 4762-12.9 63 Nm ±15 % S26-58507-0 S26-58507-5
25 BK485 4x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58475-0 S26-58475-5
32 BK506 6x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58508-0 S26-58508-5
Ød3xt3
Y4
Y
Y5
Y3
B1
Ød1
Y2
Y1
A B
B2
Cylinder
B3
lock X
Ød2
15
4
X6
L6
L7
L4
Acorn nut
with lead seal
Hand knob
H1
H4
Ød6
H3
Ød5
H2
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 B3 H1 H2 H3 H4 H6 L1 L2 L3 L4 L5 L6 L7
10 6264-06-07-*-97 87.3 33.35 70 130 21 68.5 109.5 – 25 90.8 – 143 181 165.6 144.8
25 6264-08-11-*-97 105 39.7 70 154.5 29 93 134 – 30.9 123 – 143 181 165.6 144.8
32 6264-10-15-*-97 120 48.4 70 167 30 105.5 146.5 – 29.8 143.5 – 143 181 165.6 144.8
NG Surface finish
NBR FPM
10 BK505 4x M10x35 ISO 4762-12.9 63 Nm ±15 % S26-58507-0 2) S26-58507-5 2)
25 BK485 4x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58475-0 2) S26-58475-5 2)
32 BK506 6x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58508-0 2) S26-58508-5 2)
VV01, AC solenoid S26-35237-0 S26-35237-5
VV01, DC solenoid S56-40609-0 S56-40609-5
1) Details see chapter 12, series SPP.
2) Please combine seal kit of one size with seal kit of VV01 solenoid for complete seal kit.
Features
• TÜV certificate
4 • Pilot operated with manual adjustment
• 2 interfaces:
- R4V subplate ISO 6264 (DIN 24340 Form D)
- R6V subplate ISO 6264 (DIN 24340 Form E)
with CETOP 03 vent valve
• Adjustment leaded (code W)
• Adjustment leaded to maximum pressure, lower pres- R4V06
sure possible (code V)
Name plate data
Example R4V06
415 mm² : minimum opening width
L220 l/min : max. flow
70 bar : set pressure (compare p/Q curves)
7,3 mm : cartridge stroke
10 % : permitted pressure increase of the flow
range
P X
Y
T
X Y X Y
X A B X P T
R4V / R6V
R V 5 5 0
Pressure Relief Max. Pressure Pilot oil Seals
valve function pressure setting range internal
(350 bar) 350 bar max.
Interface Nominal Body Adjustment Design Pressure
size leaded series stage
(TÜV)
Code Interface Code Pressure stage 1)
P10 100 bar
P20 200 bar
4
Subplate P30 300 bar
mounting P35 350 bar
6
ISO 6264
Code Seals
4
1 NBR
5 FPM
R 6 V 5 9 5 V 0 09 B
Pressure Relief Max. Pressure Pilot oil Solenoid Seals
valve function pressure setting range internal voltage
(350 bar) 350 bar max.
Interface Nominal Body Adjustment Vent valve Design Pressure
size Y-port = leaded (TÜV) function series stage
G 1/8“ Hand knob leaded solenoid not active,
(lower pressure ad- unpressurized
justment possible) circulation
Code Interface Code Pressure stage 1)
Subplate P10 100 bar
6 mounting P20 200 bar
ISO 6264 P30 300 bar
P35 350 bar
R4V / R6V
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 6264 (DIN 24340)
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight Series R6V [kg] 4.5 5.8 7.8
Series R4V [kg] 2.7 4.5 6.0
Hydraulic
Max. operating pressure [bar] Ports P (or A) up to 350, Port T (or B) 30
Pressure stages [bar] 350 (pressure setting see ordering code)
Nominal flow R6V [l/min] 250 500 500
R4V [l/min] 110 450 500
Fluid Hydraulic oil according to DIN 51524
4 Fluid temperature
Viscosity, permitted
[°C]
[cSt] / [mm²/s]
-20...+70 (NBR: -25...+70)
20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
R6V
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L6
10 6264-06-09-*-97 80 26.9 114 27 88 20.5 25 52 117 148.3 29.5
25 6264-08-13-*-97 100 35 117.5 46.5 91.5 – 25 12 37.9 124.5 148.3 – 36.5
32 6264-10-17-*-97 120 41.3 124.5 51.3 98.5 26.5 13.5 44.3 153 148.3 46.5
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L6
10 6264-06-09-*-97 80 26.9 203.4 27 88 136.3 25 12 52 117 163.8 36.5
25 6264-08-13-*-97 100 35 206.9 46.5 91.5 139.8 25 12 37.9 124.5 163.8 – 36.5
32 6264-10-17-*-97 120 41.3 213.9 51.3 98.5 146.8 25 12 44.3 153 163.8 36.5
R4V
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L6
10 6264-06-07-*-97 87.3 33.35 83 21 – – 62.5 – 25 90.8 – 144.8
25 6264-08-11-*-97 105 39.7 107.5 29 – – 87 – 30.9 123 – 144.8
32 6264-10-15-*-97 120 48.4 120 30 – – 99.5 – 29.8 143.5 – 144.8
Function
When the pressure in port P or A exeeds the pressure
setting at the solenoid, the cone opens to port T and limits
the pressure in port P to the adjusted level.
The optimum performance can be achieved in combina-
tion with the digital amplifier module PCD00A-400.
Also available as sandwich valve, see Chapter 8, Pilot
valves series RPDM.
Valve conform to ATEX Ex e mb ll see catalogue HY11-
3343.
Download: www.parker.com/euro_hcd - see “Literature”
4
Features
• Direct operated with proportional solenoid
• Very low pressure adjustment of pmin
• 2 pressure ports, A and P
• Subplate mounting according to ISO 6264
• 4 pressure stages
Ordering Code
RE 06 M W 2 1 W
Proportional NG06 Interface Pressure External Seals Normally Solenoid Plug Design
pressure ISO 6264 stage electronics open voltage connection series
relief valve EN 175301- (not required
803 for ordering)
General
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Interface Subplate mounting according to ISO 6264
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 150
Weight [kg] 1.8
Hydraulic
Max. operating pressure [bar] Ports P and A up to 350; port T 30
Pressure stages [bar] 105, 175, 250, 350
Nominal flow [l/min] See p/Q curves
Fluid Hydraulic oil according to DIN 51524
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
4 recommended
Fluid temperature
[cSt] / [mm²/s] 30 ... 80
[°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Linearity [%] ±2.8
Repeatability [%] <±1
Hysteresis [%] ±1.5 of pmax
Electrical
Duty ratio [%] 100 ED
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Nominal voltage [V] 12 (2.5 A max. current), 16 (1.3 A max. current)
Coil resistance at 20 °C [Ohm] 4.28 (at 12 V), 12 (at 16 V)
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
p/Q curves
Pressure stage 105 bar Pressure stage 350 bar
Pressure/signal curve
Pressure stage 105 bar Pressure stage 350 bar
RE06M*W
Features
• Direct operated with proportional solenoid
• Onboard electronics
• Very low pressure adjustment of pmin
• Subplate mounting acc. to ISO 6264
• 6 pressure stages
• 2 pressure inlet ports A and P
Ordering code
RE 06 M T 2 1 0
Proportional NG06 Interface Pressure Onboard Seals Normally Command Electronic Design
pressure ISO 6264 stages electronics open signal attachment series
relief valve (not required
for ordering)
General
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Interface Subplate mounting according to ISO 6264
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight [kg] 2.2
10 sinus 5...2000 Hz acc. to IEC 68-2-6
Vibration strength [g] 30 noise 20...2000 Hz acc. to IEC 68-2-36
15 shock acc. to IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports A and P 350, connection T 30
Pressure stages [bar] 50, 105, 175, 210, 250, 350
Nominal flow [l/min] See p/Q curves
4 Fluid
Viscosity, permitted [cSt] / [mm²/s]
Hydraulic oil according to DIN 51524
20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Linearity [%] See curve
Repeatability [%] <±1
Hysteresis [%] ±1.5 of pmax
Electrical
Duty ratio ED [%] 100
Supply voltage [VDC] 18...30, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0
Pre-fusing [A] 2.5 medium lag
Potentiometer supply [V] +10 / ±5 % max. 10 mA
Command signal
Code F voltage [V] 0...+10, ripple < 0.01 % eff., surge free, Ri = 100 kOhm
Code R current [mA] 4...20, ripple < 0.01 % eff., surge free, Ri = 200 Ohm
< 3.6 mA = enable off,
> 3.8 mA = enable on (acc. NAMUR NE43)
Differential input voltage max. [V] 30 for terminal D and E against PE (terminal G)
[V] 11 for terminal D and E against 0V (terminal B)
Adjustment ranges Min current [%] 0...50
Max current [%] 50...100
Ramp [s] 0...32.5
Interface RS 232C, parametrizing connection 5polig
EMC EN 61000-6-2, EN 61000-6-4
Central connection 6 + PE acc. EN 175201-804
Cable specification [mm²] 7 x 1.0 overall braid shield
Cable length max. [m] 50
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
Signal/pressure curve
100
Pressure [%]
80
60
40
20
0
0 10 20 30 40 50 60 70 80 90 100
Command signal [%]
4
p/Q curve
Block diagram
Code F
6 + PE acc. EN 175201-804
Code R
6 + PE acc. EN 175201-804
Port B:
O-ring recess on valve body.
Features
• Pilot operated with proportional solenoid
R6V06 R4V06
• 2 interfaces:
- R4V subplate ISO 6264 (DIN 24340 Form D)
- R6V subplate ISO 6264 (DIN 24340 Form E)
• 3 pressure stages
• Mechanical maximum pressure adjustment (optional
4
for R6V)
R6V06 R4V06
Y1 (optional)
X Y
mechanical
Y maximum
pressure
adjustment
X P T (optional)
X A B Y
R V 5 G0R
Pressure Relief Max. Pressure Pilot oil Solenoid Design
valve function pressure stages voltage series
(350 bar) 12 V / 2.3 A (not required
for ordering)
Interface Nominal Drain Mechanical Options Design Seals Modifi-
size port adjustment cations
1)
Other pressure stages on request.
2)
Use code P also for valve w/o mechanical adjustment.
3)
R4V only.
4)
R6V only.
5)
Not for R4V.
General
Nominal size 10 25 32
Interface Subplate mounting acc. ISO 6264
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight Series R6V [kg] 5.2 6.4 8.3
Series R4V [kg] 4.5 6.3 7.8
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 250 500 650
Fluid Hydraulic oil according to DIN 51524
Viscosity, permitted
recommended
[cSt] / [mm²/s] 20 ... 400
[cSt] / [mm²/s] 30 ... 80 4
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Electrical (prop. solenoid)
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage [V] 12 V =
Max. current [A] 2.1
Coil resistance at 20 °C [Ohm] 4.28
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
R4V
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 B3 H1 H2 H3 H4 H6 L1 L2 L3 L4 L5 L6
10 6264-06-07-*-97 87.3 33.35 71 130 21 68.5 109.5 – 25 90.8 – 143 144.8 164.8
25 6264-08-11-*-97 105 39.7 71 154.5 29 93 134 – 30.9 123 – 143 144.8 164.8
32 6264-10-15-*-97 120 48.4 71 167 30 105.5 146.5 – 29.8 143.5 – 143 144.8 164.8
R6V
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80 26.9 158.7 27 88 – 20.5 25 52 117 182.3 14.4 – 29.5
25 6264-08-13-*-97 100 35 161.2 46.5 91.5 – 25 12 37.9 124.5 182.3 14.4 – 36.5
32 6264-10-17-*-97 120 41.3 166.7 51.3 98.5 – 26.5 13.5 44.3 153 182.3 14.4 – 46.5
1)
Details see chapter 12, series SPP.
R4V06 R6V06
Parametrizing
connection Parametrizing
connection
Main
connection Main
connection
Mechanical
max. pressure
adjustment
R V 5 P
Pressure Relief Max. Pressure Pilot oil Command Design
valve function pressure setting signal series
(350 bar) range (not required
for ordering)
Interface Nominal Drain Proportional Options Design Seals Modifi-
size port operation cations
Code Options
Code Interface Drain port w/o mech. max.
3 R4V Y from subplate PN
adjustment
9 R6V Y-port = G 1/8“ With mech. max.
PM 4)
adjustment
1)
Other pressure stages on request.
2)
R4V only.
3)
R6V only.
4)
R4V: adjustment with acorn nut.
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 6264
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 75
Weight Series R6V [kg] 5.4 6.6 8.6
Series R4V [kg] 4.5 6.3 7.8
10 sinus 5...2000 Hz acc. to IEC 68-2-6
Vibration strength [g] 30 noise 20...2000 Hz acc. to IEC 68-2-36
15 shock acc. to IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow
Fluid
[l/min] 250
Hydraulic oil according to DIN 51524
500 650
4
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Hysteresis [%] < 1.5
Electrical
Duty ratio ED [%] 100
Supply voltage VDC 18...30, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0
Pre-fusing [A] 2.5 medium lag
Potentiometer supply [V] +10 / ±5 % max. 10 mA
Command signal
Code 10V voltage [V] 0...+10, ripple < 0.01 % eff., surge free, Ri = 100 kOhm
Code 4MA current [mA] 4...20, ripple < 0.01 % eff., surge free, Ri = 200 Ohm
< 3.6 mA = enable off,
> 3.8 mA = enable on (acc. NAMUR NE43)
Differential input voltage max. [V] 30 for terminal D and E against PE (terminal G)
[V] 11 for terminal D and E against 0V (terminal B)
Adjustment ranges Min current [%] 0...50
Max current [%] 50...100
Ramp [s] 0...32.5
Interface RS232C, parametrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection 6 + PE acc. EN 175201-804
Cable specification [mm²] 7 x 1.0 overall braid shield
Cable length max. [m] 50
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
R4V/R6V
Command/pressure curve
1)
The performance curves are measured with external drain.
For internal drain the tank pressure has to be added to curve.
Block diagram
Code 10V
6 + PE acc. EN 175201-804
Code 4MA
6 + PE acc. EN 175201-804
R4V X1
X2
X3
L4 L3 X4 d4xt4
X5 Ød2
Y4
Y5
Y3
Ød3xt3
B1
Ød1
Y2
Y1
A B
B2
L1 Ød2
L2 X6
H1
H6 (optional)
H5
H4
Ød6
Ød5
H3
H2
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-07-*-97 87.3 33.35 204.7 21 62 103 148.2 32 25 90.8 164.2 4.5 – –
25 6264-08-11-*-97 105 39.7 229.2 29 86.5 127.5 172.7 32 30.9 123 164.2 4.5 – –
32 6264-10-15-*-97 120 48.4 241.7 30 99 140 185.2 32 29.8 143.5 164.2 4.5 – –
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)
10 6264-06-07-*-97 15 7 7.1 8 M10 16 10.8 17 SPP 3M6B 910
25 6264-08-11-*-97 23.4 7.1 7.1 8 M10 18 10.8 17 SPP 6M8B 910
32 6264-10-15-*-97 32 7.1 7.1 8 M10 20 10.8 17 SPP 10M12B 910
R6V
X1
L4 L3 X3 X2
d4xt4
X5
Y3
B2
Ød2
Ød1
Y1
X P T
B1
Ød3xt3
L1
X7
L2
H1
H4
Ød6
H3
H2
Y
H6
Ød5 L6
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80 26.9 187.2 27 88 138.2 20.5 25 52 117 182.3 14.4 – 29.5
25 6264-08-13-*-97 100 35 190.7 46.5 91.5 141.7 25 12 37.9 124.5 182.3 14.4 – 36.5
32 6264-10-17-*-97 120 41.3 197.7 51.3 98.5 148.7 26.5 13.5 44.3 153 182.3 14.4 – 46.5
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)
10 6264-06-09-*-97 14.7 4.8 7.5 10 M12 20 13.5 20 SPP 3R6B 910
25 6264-08-13-*-97 23.4 6.3 7.5 10 M16 27 17.5 25 SPP 6R10B 910
32 6264-10-17-*-97 32 6.3 7.5 10 M18 28 20 30 SPP 10R12B 910
1)
Details see chapter 12, series SPP.
Features
• Proportional adjustment VBY*K06 VBY*K10
VBY*K06 VBY*K10
VBY*K06 VBY*K10
Ordering code
VBY K
Pressure Max. Proportional Nominal Seals Design
relief valve setting solenoid size series
range 9 VDC / 2.5 A (not required
for ordering)
Technical data
General
Design Proportional pressure relief valve
Nominal size NG06 NG10
Interface Subplate mounting according to ISO 5781
Actuation Proportional solenoid
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 75
Weight [kg] 2.4 4.5
Hydraulics
P, A: 315, Port B blocked, A, B: 315, Port Y blocked,
Max. operating pressure [bar]
Port T depressurized Port Y depressurized
Nominal flow [l/min] 40 160
4
Adjustment range [bar] up to 64, 100, 160, 210, 315
Fluid Hydraulic oil according to DIN 51524
Viscosity permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Linearity [%] ±3.5 at > 15 % pnom.
Repeatability [%] <±2
Hysteresis [%] <3
Response time [ms] <150 <200
Electrical
Duty ratio [%] 100 ED
Protection class IP65 at EN 60529 (with correctly mounted plug-in connector)
Nominal voltage [VDC] 9
Max. current [A] 2.7
Nom. current [A] 2.5
Ambient temperature [°C] -20...+70
Coil resistance [Ohm] 2.1 at 20 °C
Solenoid connection Connector as per EN 175301-803
Power amplifier PCD00A-400
Pressure p [bar]
60
200
180
50
160
40 140
120
30 100
80
20 typical
typical
60
40
10
20
0 0
0.0 1.0 2.0 3.0 4.0 5.0 6.0
7.0 8.0 9.0 10 0.0 1.0 2.0 3.0 4.0 5.0 6.0
7.0 8.0 9.0 10
Set value Uset [V] Set value Uset [V]
0 250 500 750 1000 1250 1500 1750 2000 2500 0 250 500 750 1000 1250 1500 1750 2000 2500
Solenoid current Is [mA] Solenoid current Is [mA]
All characteristic curves measured with HLP46 at 50 °C.
Pressure p [bar]
2500 mA
70 2500 mA
100
60
80 1875 mA
50 1875 mA
40 60
1250 mA 1250 mA
30
40
20
625 mA 20 625 mA
10 pe min
pe min
0 0
0 10 20 30 40 0 10 20 30 40
Flow Q [l/min] Flow Q [l/min]
4
Setting range max. 160 bar Setting range max. 210 bar
240
Pressure p [bar]
Pressure p [bar]
180 2500 mA
2500 mA
160 200
140
1875 mA 180 1875 mA
120
100 140
80 1250 mA
1250 mA 100
60
40 60
625 mA
20 pe min 20 625 mA pe min
0 0
0 10 20 30 40 0 10 20 30 40
Flow Q [l/min] Flow Q [l/min]
300
2500 mA
260
1875 mA
220
180
140 1250 mA
100
60
625 mA
20 pe min
0
0 10 20 30 40
Flow Q [l/min]
Setting range max. 160 bar Setting range max. 210 bar
180 240
Pressure pe [bar]
Pressure pe [bar]
2500 mA 2500 mA
160 200
140
120 180
1875 mA 1875 mA
100 140
80
1250 mA 100 1250 mA
60
40 60
20 625 mA 20 625 mA pe min
pe min
0 0
0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160
Flow Q [l/min] Flow Q [l/min]
NG06
NG10
1)
Deviating from ISO the Y port has Ø 14.7 instead of Ø 4.8.
R4U
R 4 U 5 3 A
Pressure Unloading Max. pressure Pressure Pilot oil Seals
valve function (350 bar) stages
Interface Nominal Body Adjust- Design Modifi-
size design ment series cations
4 Code
03
Nominal size
NG10
0
1
Internal
Ext. from subplate
06 NG25
10 NG32 Code Adjustment
Hand knob 32 mm
1
Pressure Pressure diameter (standard)
Code
stages differential Acorn nut
3
1 up to 105 bar 28 % with lead seal
3 up to 210 bar 28 % 4 Cylinder lock
5 up to 350 bar 15 %
R 4 U 5 3 A
Pressure Relief Max. pressure Pressure Pilot oil Solenoid Seals
valve function (350 bar) stages voltage
Interface Nominal Body Adjust- Vent valve Design Modifi-
size design ment function series cations
R4U
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 5781
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.7 4.5 6.0
Hydraulic
Max. operating pressure [bar] Ports A and X 350, Ports B and Y depressurized
Pressure stages [bar] 105, 210, 350
Pressure differential 28 % (for pressure stages 105 bar and 210 bar); 15 % (for pressure stages 350 bar)
Nominal flow [l/min] 150 350 650
Fluid
Viscosity, permitted
Hydraulic oil according to DIN 51524
[cSt] / [mm²/s] 20 ... 400
4
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
1)
The performance curves are measured with external drain.
For internal drain the tank pressure has to be added to curve.
R4U
X1
X2
X3
X4 d4xt4
X5 Ød2
Y4
Y
Y3
B1
Ød1
Y2
Y1
A B
B2
Cylinder
lock X
4
Ød2 Ød3xt3
L1
L2 X6
L5 30 X7
L6
L4
Hand knob
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9 – –
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73 39.7 6.4 – –
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8 – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.35 83 21 – – 62.5 – 25 90.8 – 143 181 144.8
25 5781-08-10-0-00 105 39.7 107.5 29 – – 87 – 30.9 123 – 143 181 144.8
32 5781-10-13-0-00 120 48.4 120 30 – – 99.5 – 29.8 143.5 – 143 181 144.8
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)
10 5781-06-07-0-00 15 7 7.1 8 M10 16 10.8 17 SPP 3M6B 910
25 5781-08-10-0-00 23.4 7.1 7.1 8 M10 18 10.8 17 SPP 6M8B 910
32 5781-10-13-0-00 32 7.1 7.1 8 M10 20 10.8 17 SPP 10M12B 910
1)
Details see chapter 12, series SPP.
Y4
Hand knob Y
Y3
B1
Ød1
Y2
Y1
A B
B2
Cylinder
B3
lock X
4
Ød2 Ød3xt3
15
X6
X7
L6
L4
H1
H4
Ød6
H3
Ød5
H2
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9 – –
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73 39.7 6.4 – –
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8 – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 B3 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.35 70 130 21 68.5 109.5 – – 25 90.8 – 143 181 165.6
25 5781-08-10-0-00 105 39.7 70 154.5 29 93 134 – – 30.9 123 – 143 181 165.6
32 5781-10-13-0-00 120 48.4 70 167 30 105.5 146.5 – – 29.8 143.5 – 143 181 165.6
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)
10 5781-06-07-0-00 15 7 7.1 8 M10 16 10.8 17 SPP 3M6B 910
25 5781-08-10-0-00 23.4 7.1 7.1 8 M10 18 10.8 17 SPP 6M8B 910
32 5781-10-13-0-00 32 7.1 7.1 8 M10 20 10.8 17 SPP 10M12B 910
Features
• Pilot operated sequence valve
• Subplate mounting acc. to ISO 5781
• 3 pressure stages
• 3 adjustment modes:
- hand knob
- acorn nut with lead seal
- cylinder lock 4
Ordering code
R 4 S 5 3 1 A
Pressure Interface Relief Nominal Max. Body Pressure Adjust- External Design Seals
valve function size pressure design stages ment drain series
(350 bar) from
subplate
Technical data
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 5781
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.7 4.5 6.0
Hydraulic
Max. operating pressure [bar] Ports A, B and X 350, port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 150 350 650
Fluid Hydraulic oil according to DIN 51524
4 Viscosity, permitted
recommended
[cSt] / [mm²/s] 20 ... 400
[cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
P1 = setting pressure
P2 = operating pressure
Time and pressure underlap depend on the characteristics of the specific system.
X1
X2
X3
X4 d4xt4
X5 Ød2
Y4
Y3
B1
Ød1
Y2
Y1
A B
B2
Cylinder
lock X
L1
L2 X6
Ød2 Ød3xt3
4
L5 30 X7
L6
L4
Hand knob
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9 – –
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73 39.7 6.4 – –
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8 – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.35 83 21 – – 62.5 – 25 90.8 – 143 181 144.8
25 5781-08-10-0-00 105 39.7 107.5 29 – – 87 – 30.9 123 – 143 181 144.8
32 5781-10-13-0-00 120 48.4 120 30 – – 99.5 – 29.8 143.5 – 143 181 144.8
4 Features
• Spool type valve
• Subplate mounting acc. to ISO 5781
• 5 pressure stages at NG06
• 3 pressure stages at NG10
• 2 adjustment modes
NG06 NG10
NG06
A P T
NG10
B Y A
VM UK.indd RH 17.04.2015
Ordering code
VM A V
Pressure Pressure Adjustment Nominal FPM Gauge Lock Design
reducing stages screw size seals port series
valve with (not required
hexagon for ordering)
socket
Code Lock
Code Pressure stages
omit –
025 1) up to 25 bar
Z Key lock
064 up to 64 bar
125 2) up to 125 bar
160 1)
210
up to 160 bar
up to 210 bar
Code
G 1)
Gauge port
G 1/4”
4
350 1) up to 350 bar
M 2) M18x1.5
1)
Only NG06.
2)
Only NG10.
Technical data
General
Design Pressure reducing valve, direct operated, spool type
Nominal size NG06 (CETOP 03 / NFPA D03) NG10 (CETOP 05 / NFPA D05)
Interface Subplate mounting according to ISO 5781
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.3 3.7
Hydraulics
Port P and A 350 Port A and B 350
Max. operating pressure [bar]
Port T depressurized Port Y depressurized
Pressure stages [bar] 25; 64; 160; 210; 350 64; 125; 210
Nominal flow [l/min] 25 60
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity permitted [cSt]/ [mm²/s] 20...400
recommended [cSt]/ [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
VM UK.indd RH 17.04.2015
NG06 setting pressure max. 25 bar NG06 setting pressure max. 160 or 210 bar
VM UK.indd RH 17.04.2015
NG06
VM UK.indd RH 17.04.2015
NG10
1)
Deviating from ISO the Y port has Ø 14.7 instead of Ø 4.8.
VM UK.indd RH 17.04.2015
Features
• Pilot operated with manual adjustment
• Subplate mounting acc. to ISO 5781
• Normally closed to avoid unintended motion
• 3 pressure stages
• 3 adjustment modes:
- hand knob
4
- acorn nut with lead seal
- cylinder lock
Ordering code
R 4 R 5 9 B
Pressure Interface Reducing Nominal Max. Pilot Pressure Adjust- Pilot oil Design Seals Modifi-
valve function size pressure ports stages ment series cations
(350 bar) G1/4“
1)
Further pressure stages on request.
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 5781
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 4.8 7.2 13.5
Hydraulic
Max. operating pressure [bar] Ports A, B and X 350, port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 150 350 500
Fluid Hydraulic oil according to DIN 51524
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
4
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
4
Reduced pressure pA versus flow Q
R4R06 1) Minimum pressure curve
80
Pressure p [bar]
70
60
50
40
30
20
10
1)
Measured at 350 bar primary pressure pB.
X1
X2
X3
X4 d4xt4
X5 Ød2
Y4
Y
Y3
B1
X1 Y1
Ød1
Y1
A B
B2
Cylinder lock
4 L1
L2 X7
Ød3xt3
L5 30
L6
L4
L3
L7 Acorn nut
with lead seal
X1 Y1 X1: G 1/4“
Y1: G 1/4“
Ød5
H3
H2
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 – 31.8 66.7 – 33.4 7.9 – –
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 – 44.5 79.4 – 39.7 6.4 – –
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 – 62.7 96.8 – 48.4 3.8 – –
Tolerance for all dimensions ±0.2
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6 L7
10 5781-06-07-0-00 87.3 33.35 87 21 62.5 – – – 25 90.8 60.8 143 181 144.8 38.6
25 5781-08-10-0-00 105 39.7 111.5 29 87 – – – 30.9 123 60.8 143 181 144.8 38.6
32 5781-10-13-0-00 120 48.4 124 30 99.5 – – – 29.8 143.5 60.8 143 181 144.8 38.6
VMY*K06N VMY*K10
Neutral position
Ordering code
VMY K 1 P
Reducing Pressure Proportional Nominal Pilot Seals Design High
valve stages solenoid size series pressure
9 V / 2.5 A channel
Technical data
General
Design 3 way proportional reducing valve, pilot operated, spool design
Nominal size 06 (DIN NG06/CETOP 03/NFPA D03) 10 (DIN NG10/CETOP 05/NFPA D05)
Interface Subplate mounting according to ISO 5781
Actuation Proportional solenoid
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 75
Weight [kg] 2.8 5
Hydraulics
Max. operating pressure Size 06:
[bar] Ports P, A 315; Port T, Y depressurized; port B has to be blocked
Size 10:
[bar] Ports A, B 350; Port Y depressurized; port X has to be blocked
Pressure stages [bar] 64, 100, 160, 210, 315
Nominal flow [l/min] 40 160
Fluid Hydraulic oil according to DIN 51524
Viscosity permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Linearity [%] See characteristic pressure curves ±3.5 at > 15 % pnom.
Repeatability [%] <±2
Hysteresis [%] <3
Response time [ms] <150 <200
Electrical
Duty ratio [%] 100 ED
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Nominal voltage [VDC] 9
Max. current [A] 2.7
Nom. current [A] 2.5
Ambient temperature [°C] -20...+70
Coil resistance [Ohm] -2.1 (at 20 °C)
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
1)
Connection on port Y1 or Y2.
2)
Not for NG06.
Pressure p [bar]
Pressure p [bar]
60
200
55
180
50
160
45
40
140
4
35 120
30 100
25
80
20 Q = 0 l/min
Q = 0 l/min 60
15 typical characteristic
typical characteristic curve
curve 40
10
20
5
0 0
0 1 2 3 8 4
9 10 5 6 7 0 1 2 3 4 5 6
7 8 9 10
Set value Uset[V] Set value Uset[V]
1 250 500 750 1000 1250 1500 1750 2000 2250 2500 1 250 500 750 1000 1250 1500 1750 2000 2250 2500
Solenoid current IS [mA] Solenoid current Is [mA]
Flow A - T Flow P - A
80
2500 mA
60
1875 mA
40
1250 mA
20
625 mA
0 mA pmin
40 30 20 10 0 10 20 30 40
Flow Q [l/min]
60
1250 mA
40
20 625 mA
0 mA pmin
40 30 20 10 0 10 20 30 40
4
Flow Q [l/min]
180 2500 mA
160
140 Flow A - T Flow P - A
120 1875 mA
100
80
1250 mA
60
40
625 mA
20 0 mA pmin
0
40 30 20 10 0 10 20 30 40
Flow Q [l/min]
220 2500 mA
Flow A - T Flow P - A
180
1875 mA
140
100 1250 mA
60
625 mA
20 0 mA pmin
40 30 20 10 0 10 20 30 40
Flow Q [l/min]
2500 mA
300 Flow A - T Flow P - A
260
1875 mA
220
180
140 1250 mA
100
60 625 mA
20 0 mA pmin
40 30 20 10 0 10 20 30 40
Flow Q [l/min]
All characteristic curves measured with HLP46 at 50 °C.
Step response
Typical curve
4
Setting range max. 100 bar
NG06
Port Y: G1/4
4
VMY*K06T:
Ports Y1 and Y2: closed
VMY*K06N:
Drain port Y1 or Y2
Port Y1 closed,
Port Y2 opened
The connection
B must be locked
onto the subplate
for standard ap-
plications.
NG10
1)
Deviating from ISO the Y port has Ø 14.7 instead of Ø 4.8.
Features
• Pilot operated with proportional solenoid
• Continuous adjustment by proportional solenoid
• Subplate mounting according to ISO 5781
• 3 pressure stages
• With mechanical maximum pressure adjustment
4
Ordering code
R 4 R 5 9 P2 G0R B
Pressure Reducing Max. pressure Pressure Pilot oil Solenoid Seal
valve function 350 bar stages voltage
Interface Nominal Pilot ports Adjustment Prop. 12 V, 2.3 A Design Modifi-
size G1/4“ operation series cations
Technical data
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 5781
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.7 4.5 6.0
Hydraulic
Max. operating pressure [bar] Ports A, B and X 350, port Y depressurized
Pressure stages [bar] 105, 250, 350
Nominal flow [l/min] 150 350 500
Fluid Hydraulic oil according to DIN 51524
4 Viscosity, permitted
recommended
[cSt] / [mm²/s]
[cSt] / [mm²/s]
20 ... 400
30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406 (1999); 18/16/13
Electrical
Duty ratio [%] 100 ED
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Nominal voltage [V] 12
Max. current [A] 2.3
Coil resistance [Ohm] 4 at 20 °C
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
Command/pressure curves
4
Reduced pressure pA versus flow Q
R4R06 1) Minimum pressure curve
400
Reduced pressure pA [bar]
350 80
Pressure p [bar]
300 70
60
250
50
200
40
150
30
100
20
50 10
0 100 200 300 400 500 0 100 200 300 400 500
Flow Q [l/min] Flow Q [l/min]
X1: G 1/4“
Y1: G 1/4“
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 – 31.8 66.7 – 33.4 7.9 – –
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 – 44.5 79.4 – 39.7 6.4 – –
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 – 62.7 96.8 – 48.4 3.8 – –
Tolerance for all dimensions ±0.2
NG ISO-code B1 B2 B3 H1 H2 H3 H4 L1 L2 L3 L4 L5 L6 L7
10 5781-06-07-0-00 87.3 33.35 71 134 21 68.5 109.5 25 90.8 60.8 143 144.8 164.8 38.6
25 5781-08-10-0-00 105 39.7 71 158.5 29 93 134 30.9 123 60.8 143 144.8 164.8 38.6
32 5781-10-13-0-00 120 48.4 71 171 30 105.5 146.5 29.8 143.5 60.8 143 144.8 164.8 38.6
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)
10 5781-06-07-0-00 15 7 7.1 8 M10 16 10.8 17 SPP 3M6B 910
25 5781-08-10-0-00 23.4 7.1 7.1 8 M10 18 10.8 17 SPP 6M8B 910
32 5781-10-13-0-00 32 7.1 7.1 8 M10 20 10.8 17 SPP 10M12B 910
4
Plug with LED insert 24 V and supressing circuitry PG11
grey, A Fig. 5 5001709
Plug with rectifier. Rectifier with 4 silicon diodes in bridge
black, B Fig.1 and 5001737
circuit. Varistor in alternating current side to protect the PG11
grey, A Fig. 6 5001738
diodes against power peaks
black, B 5001723
Plug with pull relief and translucent cover PG11 Fig. 2
grey, A 5001724
Application with bridge rectifier suitable for 5001723 and Fig. 2 and
— — 5001727
5001724 Fig. 7
Application with bridge rectifier and lamp suitable for Fig. 2 and
— — 5001734
5001723 and 5001724 Fig. 8
1)
EN 175301-803 (new) corresponding with DIN 43650 (old).
Access04.indd RH 17.04.2015
Central connector
Access04.indd RH 17.04.2015
Subplate
Screw-in
Parker Standard 1/4 3/8 1/2 3/4 1
DIN / ISO 06 10 16
Content05.indd RH 17.04.2015
Characteristic values
Operating Flow Kv
Max. orifice Weight
Size press. [l/min] factor
area [cm2] [kg]
[bar] Dp 10 bar valve
400 350 25 0.14 6.3 0.18
600 350 65 0.37 18.5 0.32
800 350 105 0.55 27.5 0.59
1200 350 160 0.90 45.7 0.95
5 Needle size
400-2 11 0.52
400-3 2 0.012
∆p/Q curves
Kv see table
∆p [bar]
γ [kg/dm3] = specific gravity of fluid
(γ for mineral oil = 0.85 – 0.9)
MVI S
Cartridge- Size and Steel body Needle Seal
type screw-in
needle threads
valve
Code Size Threads Code Seal
400 1/4" 3/4 - 16 UNF-2B omit NBR
600 3/8" 7/8 -14 UNF-2B V FPM
800 1/2" 1 1/16 - 12 UN-2B
1200 3/4" 1 5/16 - 12 UN-2B Code Needle
Standard 30°
omit
taper
2 1) Fine V-notch
Micro-fine
3 1)
1) Only for size 400. slotted
5
Size H H3 H2 H1 Ød1 Ød2 R (Threads) ØD SW
MVI 400 25.4 65 60 10.9 4.6 14.22 3/4 - 16 UNF-2 51 22.1
MVI 600 30 81 73 13.5 7.9 15.8 7/8 - 14 UNF-2 64 25.4
MVI 800 39.6 91 79 15.2 9.4 20.55 1 1/16 - 12 UN-2 83 31.8
MVI 1200 43.4 102 88 19.1 11.7 26.92 1 5/16 - 12 UN-2 98 38.1
Mounting cavity
Size Ød3 Ød4+ 0.12 Ød5 (min) Ød6+ 0.05 Ød7 T4+ 0.38 T2 T3 T T1
MVI 400 26 20.6 5.3 14.275 5.3 2.54 15 17.8 27 14.2
MVI 600 30 23.93 8.1 15.85 8.1 2.54 17 21.6 32 16.5
MVI 800 37 29.16 10.2 20.6 10.2 3.3 19 30 42 24.1
MVI 1200 44 35.54 12.7 26.975 12.7 3.3 19 31.8 46 24.6
5
Characteristic values
(only for standard 2 stage needle)
Press. [bar] Flow Max. cross- Kv factor
Weight
Size [l/min] section valve Flow rate Q [l/min] = Kv · ∆p
steel brass Dp 10 bar [kg]
[cm2] open
γ
400 210 140 25 0.13 6.3 0.4
600 210 140 40 0.22 11.2 0.6 Kv from the table
∆p [bar]
800 210 140 50 0.28 13.9 1.0
γ [kg/dm3] = specific weight of the medium
1200 210 140 120 0.70 35.4 2.0 (γ for mineral oil = 0.85 – 0.9)
1600 210 35 250 1.48 75 4.0
Ordering code
N S S
Needle Subplate Size Steel body Needle Clamping Seal
valve mounting screw
1)
Only for sizes 400 to 600.
NS UK.indd RH 17.04.2015
∆p/Q curves
Hexagon adjusting
knob, standard for
size 1600
NS UK.indd RH 17.04.2015
5
Kv from the table
∆p [bar]
γ [kg/dm3] = specific gravity of fluid
(γ for mineral oil = 0.85 – 0.9)
Characteristic values
Pressure Max. flow Opening Check Throttle Throttle v. open Weight
Size
[bar] [l/min Dp10 bar] [cm2] Kv factor surface [cm2] Kv factor [kg]
400 1) 210 25 0.37 18.6 0.13 6.3 0.23
600 1) 210 40 0.62 30.4 0.22 11.2 0.31
800 1) 210 50 0.86 43.4 0.28 14 0.67
1200 1) 210 120 1.18 60 0.70 35.4 1.17
1600 1) 210 250 2.23 111 1.48 75 2.31
1)
MTTFD value 150 years
Ordering code
F S S
Throttle and Subplate Size Steel body Needle Clamping Seal
check mounting screw
valve
1)
Only for sizes 400 to 600.
FS UK.indd RH 17.04.2015
Dimensions
Hex head
adjusting knob
Standard for
Size 1600
FS UK.indd RH 17.04.2015
Characteristic values
Ordering code
PC M S S
Pressure Check Manual Subplate Size Steel Clamping Seal Design
compens. valve adjustment mounting body screw series
flow (not required
control valve for ordering)
1)
Min. and max. flow rate.
Controlled flow vs. pressure drop Reverse flow vs. pressure drop at minimum and
maximum settings
Sizes 400, 600 and 1200
5
All characteristic curves measured with HLP46 at 50 °C.
Dimensions
Design
The 2-way flow control valves are used with a triangular
GFG 2 PKC
flow restrictor and a subsequent pressure compensator.
The setting of the flow rate can be locked by a cylinder
lock in the adjusting knob against unauthorized adjust-
ment (option S).
Features
• Flow rate independent of pressure and temperature
• Available for 7 different flow rates
• Good fine adjustment
• External port (P) to block flow from A to B
• Optional reverse flow check valve
• Turn knob with cylinder lock (option S)
(P)
Note A B
Rectifier plate and subplates see 'Accessories' at the
end of this chapter. Flow restrictor Pressure compensator
Ordering code
GFG 2 PK 10
2-way flow Nominal Pressure Check Locking Flow Seal Design Pilot
control valve Size compensated valve option series port
NG06
Code Seal
Code Locking option omit NBR
Standard V FPM
omit
without lock
S
With
cylinder lock
5
Code Flow [l/min]
0.6 0.015 to 0.6
1.0 0.015 to 1.0
1.6 0.015 to 1.6
3.2 0.025 to 3.2
6.3 0.025 to 6.3
12.0 0.080 to 12.0
18.0 0.080 to 18.0
Technical data
Design Orifice, infinitely variable, pressure-compensated
Actuator Manual flow rate adjustment
Mounting type ISO 6263
code: ISO 6263-AB-03-4-B
Mounting position unrestricted
MTTFD value [years] 150
Weight [kg] 1.1 (without subplate)
Ambient temperature [°C] -20...+60
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtering ISO 4406 (1999); 18/16/13
Min. pressure difference [bar] 5 (GFG*1.6/3.2), 8.5 (GFG*6.3/12/18)
Operating pressure [bar] A; B = 315 , P = 5 (GFG*, GFG*C), A, B, P = 160 (GFG*X)
Effect of pressure on Qmax at p = 160 bar [%] ± 2 (GFG*1.6/3.2/6.3/12), ± 2.5 (GFG*18)
Flow direction
A → B Flow control function
B → A Throttle function or free flow through check valve
Performance curves
Dimensions
7 40.5
7.5
31.75
Ø5.5
20
119 (with cylinder lock)
92.6 (standard)
Only at external
pilot pressure
A P (Code X).
52
46.5 62 View in
direction
68 “X“.
X
Design
The intermediate rectifier plate is designed with 4 iden-
tical, symmetrically arranged check valves. Thus the
differential pressure is the same in both flow directions.
5
Dimensions
Dimension tolerances
* : ± 0.1mm
others : ± 0.2 mm
holes and silhouette of valve body : untoleranced dimension
Ordering code: HR OA 06 C
Function
The compensator spool is located in front of the metering
spool. The metering spool is closed in the neutral position
to avoid undesired initial actuator motion. The oil flow to with check valve
open the metering spool has to pass a needle valve (not
shown in the sectional drawing). The needle valve can
be adjusted from the front panel to set the response time
of the 2F1C.
The metering spool is adjusted by the main control knob.
The key lock has three positions:
Lock: Adjustment is locked.
5 Adjust: Full adjustment is permitted.
Trim: Fine adjustment of ±5 % is possible.
Features
• 2-way flow control valve
• Subplate mounting according to ISO 6263
• Excellent fine adjustment
• Adjustable response time
• Closed in neutral position
• Optional reverse flow check valve
• 2 sizes, NG10 (3/8“), NG16 (3/4“)
Ordering code
2F1C 01 B 5
2-way Size Adjustment Design Seal Reverse Options
flow control knob with series FPM flow check
valve lock
General
Design Orifice, infinitely variable, pressure-compensated
Actuator Manual flow rate adjustment
Mounting type ISO 6263
Mounting position unrestricted
MTTFD value [years] 150
Weight [kg] 6.0 (2F1C02), 9.0 (2F1C03)
Ambient temperature [°C] -20...+60
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtering ISO 4406 (1999); 18/16/13
Min. pressure difference [bar] see diagram
Max. operating pressure 2F1C02 2F1C03
Port A [bar] 14...280 14...350
Port B [bar] 0...270 0...340
Flow direction
A → B
B → A
Flow control function
blocked or free flow through check valve 5
Performance curves
Flow / knob adjustment characteristics at 210 bar
X2
L1 X1 X6
Y2
0
B1
Y1
0
Y4
LOCK ADJUST TRIM
INCREASE
B
Ød4
FLOW
Response time
B2
adjustment
Y3
Y5
L2 Ød1 d3 X4 X3
H3 X5
5
H2
H1
Ød2
45
Size ISO-code x1 x2 x3 x4 x5 x6 y1 y2 y3 y4 y5
02 6263-AM-07-2-A 76.2 79.4 9.5 44.5 19 – 82.5 23.8 30.2 41.3 39.7
03 6263-AK-06-2-A 101.6 103.2 20.6 52.4 31.8 0.8 101.6 28.6 15.1 75.4 26.2
Size ISO-code B1 B2 H1 H2 H3 L1 L2 d1 d2 d3 d4
02 6263-AM-07-2-A 101.6 38.1 119.6 87.4 6.4 95.2 47.6 6.4 57.2 8.7 14.2
03 6263-AK-06-2-A 124 42.9 121.4 89.2 6.4 124 62 9.5 57.2 10.5 22.4
Function
When solenoid current is applied, the metering spool
opens against the reset spring and the flow is regulated
by the pressure compensating spool to port B.
With the aid of the pressure compensating spool, the
pressure drop is held constant on the metering window.
Thus pressure load changes are compensated, and the
oil flow remains constant.
In combination with the digital electronic module
Features
• Low hysteresis
• High reproducibility
• Load-independent oil flow
• Bypass check valve
• Mounting pattern to ISO 6263
• 5 flow rates
Note
Rectifier plate and subplates see ‘Accessories’ at the end
of this chapter.
Ordering code
DUR L 06 P K
2-way flow control Nominal Linear Size Progressive Seal Design
valve with bypass flow solenoid NG06 performance series
check valve 24 V / 0.68 A curve (not required
for ordering)
Technical data
Design Electrically adjustable orifice valve with load sensing
Mounting type Subplate NG06, interface DIN 24340, ISO, CETOP
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.6
Type of voltage [V] 24
Solenoid nominal current [mA] 680
Duty cycle 100 % ED
Solenoid connection Connector as per EN 175301-803
Protection class IP 65 in accordance with EH60529 (with correctly mounted plug-in connenctor)
Amplifier module PCD00A-400
Operating pressure [bar] max. 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viskosität, permitted [cSt] / [mm²/s] 20 ... 400
Filtration
recommended [cSt] / [mm²/s] 30 ... 80
ISO 4406 (1999); 18/16/13
5
Min. pressure difference [bar] DUR 1.6/3.2: 3; DUR 6.3/12: 5; DUR 18: 8
Hysteresis at Qnom [%] 6
Hysteresis at Q ≤ 20 % • Qnom [%] 6
Repeatability at ∆Uset = 5 V [%] 2
Performance curves
DUR 1.6 L 06 PK* DUR 12 L 06 PK* / DUR 18 L 06 PK*
1.8 20
1.6 18
1.4 16
1.2 14
12
1.0
10
0.8
8
Flow Q [l/min]
Flow Q [l/min]
0.6 6
0.4 4
0.2 2
0 0
0 20 40 60 80 100 0 20 40 60 80 100
Solenoid current [%] Solenoid current [%]
3
2
1
0
0 20 40 60 80 100
Solenoid current [%]
Mounting pattern
3 60 3
7
7.55
46.5
90
5 15° PG11
118.5
125
55
Seal kits
NBR FPM
SK-DUR***L SK-DUR***L FPM
Design
The intermediate rectifier plate is designed with 4 iden-
tical, symmetrically arranged check valves. Thus the
differential pressure is the same in both flow directions.
5
Dimensions
Dimension tolerances
* : ± 0.1mm
others : ± 0.2 mm
holes and silhouette of valve body : untoleranced dimension
Ordering code: HR OA 06 C
Subplate
Screw-in
Slip-in
Parker Standard 1/8 1/4 3/8 1/2 3/4 1
DIN / ISO 06 10 16 25 32
Shuttle valves
SSR • • • 6-2
Check valves,
direct operated
RK / RB • • • • • 6-4
CS • • • • • • 6-7
SPZBE • • • • 6-9
SPV / SPZ • • • 6-11
C4V • • • • 6-13
Check valves,
pilot operated
CPS • • • 6-16
C4V • • • • 6-18
2/2-way seat valves
D4S
Accessories
• • • • 6-22
6
Plugs 6-32
content06.INDD CM 16.04.15
Features
• Little space required
• Leak-free
• Easy assembly
6 Ordering code
SSR B 080 E
Seal Shuttle Design Factory Threaded Valve
valve series norm, cartridge size
direct
operated
Code Seal Code Size
omit NBR 06 NG06
V FPM 10 NG10
Technical data
General
Design Threaded cartridge valve
Mounting position Unrestricted
Ambient temperature [°C] -20 ... +60
Nominal size NG06 NG10
Weight [kg] 0.5 0.8
Hydraulic
Flow direction See symbols
Fluid Hydraulic oil as per DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
Nominal pressure [bar] 350
Flow [l/min] 40 60
Mounting cavity 6
Seal kits
NG NBR seals FPM seals
06 SK-SSRB0E06 SK-SSRB0E06V
10 SK-SSRB0E10 SK-SSRB0E10V
1) Please note the material specification for tightening torque in chapter 12, "accessories"
Type RB
Ordering code
K
direction
in the blocked
0 1)
1
10
20
G1/8A
G1/4A
NBR
NBR
direction
2 50 G3/8A NBR
in open flow
B 3 80 G1/2A NBR
direction
Technical data
Series design with pipe thread
General
Code RK0 RK1 RK2 RK3 RB1 RB2 RB3
Flow [l/min] 10 20 50 80 20 50 80
Operating pressure [bar] 700 700 700 500 700 700 500
Opening pressure [bar] 0.15 0.18 0.2 0.25 0.15 0.07 0.17
Thread (DIN ISO 228/1) G1/8A G1/4A G3/8A G1/2A G1/4A G3/8A G1/2A
Tightening torque* ±20 % [Nm] 10 15 20 40 15 20 40
Weight [g] 5 5 15 15 5 15 20
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
Hydraulic
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -25...+70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
* In case of strong vibration, it is recommended to secure the mounting threads.
Mounting direction
6
Type RK Type RB
Screwed in, in the blocked direction Screwed in, in the open flow direction
Mounting tool
Type RK
Ordering
Type D2 a d3
number
RK0 5005216 8.6 2 1.5
RK1 5005217 11.5 2.5 2
RK2 5005218 15 2 2.5
RK3 5005219 18.8 4 3.5
Type RK Type RB
Type RK Type RB
Mounting cavity
• for connecting in combination with tube fitting
• for internal line channels
* Required depth depending on type of screw plug, connecting plate etc. used.
1) Thread runout x must be maintained. It may be smaller, but not larger (requirement for a perfect seal using the O-ring).
2) Fully cut-out thread
Ordering code
CS S
Technical data
General
Size 400 600 800 1200 1600
MTTFD value [years] 150
Weight [kg] 0.5 0.7 1.0 2.3 3.5
Ambient temperature [°C] -20 ... +60
Hydraulic
Operating pressure [bar] 210 210 210 210 210
Pressure drop ∆p [bar] 10 10 10 1 1
Flow [l/min] 65 110 155 112 160
Fluid Hydraulic oil as per DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
CS UK.INDD CM 06.11.14
Dimensions
6
CS UK.INDD CM 06.11.14
Features
• Little space required
• Leak-free from port B to A
• 4 different opening pressures
Ordering code
SP Z BE 1010 E 6
Seal Check Flow Design Factory Slip-in Valve Opening
valve direction series, norm, valve size pressure
A to B screwed poppet,
Code Seal cover direct Code Pressure [bar]
operated
omit NBR L 0.1
V FPM N 0.5
S 1.6
Code Size U 4.0
16 NG16
25 NG25
32 NG32
Technical data
General
Design Threaded cartridge valve
Nominal size NG16 NG25 NG32
Mounting position Unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 150
Weight [kg] 0.25 0.5 1.2
Hydraulic
Flow direction Port A to B
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
Nominal pressure [bar] 350
Opening pressure [bar] 0.1; 0.5; 1.6 and 4.0
Flow [l/min] 250 450 900
SPZBE UK.INDD CM 16.02.15
Dimensions
Dimensions NG16 NG25 NG32
D 40 55 72
L 72.5 89 109.5
d M33x2 G1½" G2"
l 66 80.5 99.5
SW 17 24 32
Springs
Ordering Number
Spring Type NG16 NG25 NG32
L 0.1 bar 45051368 45051375 45051376
N 0.5 bar 45051369 45051374 45051377
S 1.6 bar 45051370 45051372 45051378
U 4.0 bar 45051371 45051373 45051379
Mounting cavity
Size NG16 NG25 NG32
ød6min d1 18 25.5 36
ød5 0.5min
d2H7 25 34 45
d3 31 45 57
t6min
d6min 41 56 73
t2+0.1 66 80.5 99.5
t6max
t6max - t6min
t3
t3 53 66.5 84.5
max Ø
t2
t4 2 2.5 2.5
15° t5 21 25 30
Rmax 8
t6min 16 16 24
t4
t6max 52.5 66 84
Seal kits
ød1 NG NBR seals FPM seals
ød2 16 SK-SPZBE10E16 SK-SPZBE10E16V
ød3
25 SK-SPZBE10E25 SK-SPZBE10E25V
32 SK-SPZBE10E32 SK-SPZBE10E32V
1) Please note the material specification for tightening torque in chapter 12, "accessories".
Features
• Little space required
• Leak-free
• Easy assembly
Ports
Ordering code 6
SP B 030 E M
Seal Check Flow Design Factory Threaded Valve Spring
valve direction series norm, cartridge size 0.3 bar
direct
Code Seal operated Code Size
omit NBR 06 NG06
V FPM 10 NG10
Technical data
General
Design Threaded cartridge valve
Nominal size NG06 NG10
Mounting position Unrestricted
Ambient temperature [°C] -20 ... +60
Weight [kg] 0.5 0.8
Hydraulic
Flow direction See symbols
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
Nominal pressure [bar] 350
Opening pressure [bar] 0.3
Flow [l/min] 40 60
SPV-SPZ UK.INDD CM 16.02.15
Seal kits
NG NBR seals FPM seals
06 SK-SPV/ZB0E06 SK-SPV/ZB0E06V
10 SK-SPV/ZB0E10 SK-SPV/ZB0E10V
1) Please note the material specification for tightening torque in chapter 12, "accessories".
Function
The pressure arising in port A lifts the poppet from the
valve seat and releases the flow to B. In the counter direc-
tion, the spring and the pressure on top of the cartridge
hold the poppet onto the seat and block the flow.
C4V06
C4V10
Ordering code
C4V 5 3 0 B
Technical data
General
Nominal size NG10 NG25 NG32
Subplate mounting ISO 5781
Mounting position Unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 2.8 4.6 6.1
Hydraulic
Max. operating pressure [bar] 350
Nominal flow [l/min] 150 270 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
6
∆p/Q performance curve
NG ISO-code x1 x2 x3 x4 x5 y1 y2 B1 B2 H1 H2 H3 L1 L2
10 5781-06-07-0-00 42.9 35.8 – 7.2 31.8 66.7 33.4 87.3 33.4 83 21 45 29 94.8
25 5781-08-10-0-00 60.3 49.2 – 11.1 44.5 79.4 39.7 105 39.7 107.5 29 69.5 34.7 126.8
32 5781-10-13-0-00 84.2 67.5 42.1 16.7 62.7 96.8 48.4 120 48.4 120 30 82 30.6 144.3
Tolerance for all dimensions ±0.2
NG ISO-code d1max d2 t1 d3 t2 d4 d5
10 5781-06-07-0-00 15 7.1 8 M10 16 10.8 17
25 5781-08-10-0-00 23.4 7.1 8 M10 18 10.8 17
32 5781-10-13-0-00 32 7.1 8 M10 20 10.8 17
Ordering code
CP S S M
6
1200 1200 (¾") V FPM
Pilot ratios
Poppet 1 stage Poppet 2 stage
Dimensions
H1
H
B A
H2
A to B free flow direction
L5
L11
L4
L3 L10
L2
H3 L1 L9
SW 25.4 (600)
SW 38.0 (1200)
CPS600S 76.2 101.6 120.7 10.7 1.0 50.8 25.4 12.7 7.9 – 108.0 60.2 12.7 8.6 38.1 67.3 76.2 11.2 21.3 53.3
CPS1200S 93.7 127.0 152.4 11.4 1.0 63.5 31.8 12.7 10.2 7.9 136.4 76.2 15.7 10.2 50.8 91.2 101.6 19.1 25.4 63.5
Function
When no pressure is applied to the X-port, the flow from
B to A is blocked, because the pressure in B is also in
effect on top of the poppet.
Pressurizing the X port relieves the area on top of the
poppet to the drain port and allows flow from B to A.
The seat design of the SVL valve series provides leak-free
separation of port A and B in the closed position.
Ordering code
C4V 5 9 B
Check valve Nominal Max. Y1-port Opening Approx. Design Seal Options
pilot operated size pressure G¼" ratio cracking series
350 bar pressure
C4V pilot oper. UK.INDD CM 16.04.15 Characteristic curve measured with HLP46 at 50 °C.
Position control by proximity switch with amplifier. The Function PNP, contact
closed position is monitored. Supply voltage (Us) [VDC] 10...30
Supply voltage ripple [%] ≤ 10
Valve open: proximity switch activated.
Current consumption [mA] max. 8
This proximity switch is pressure proof and has no wear- Residual voltage L-signal [V]Us - 2.2 at lmax
ing parts. Output current (I) [mA] ≤ 200
Protection class IP67
Note: Position control for C4V06 and C4V10 only. Ambient temperature [C°] -25...+70
Wire cross section [mm2] 3 x 0.5
156.5 U (V)
40.5 L signal
US
Y1 to tank 2.2
6 Cap 0 stroke
38
PNP contact
brown +
Position Cover US
47
control Code DC
013 blue
Cable 2 m lg. 0V
-
(l) black
Body
C4V
B RL (relais)
L2 X1
X2
L1 X4 d4xt4
X5
Must be
Y3
closed by
counterpart
Y1
Ød1
Y2
Y1
B1
A B
B2
X
Ød2 Ød3xt3
X6
L5 L4 X7
L3
Y1 to tank
6
Ød6
H1
Ød5
H3
H2
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 – – 7.2 21.5 31.8 66.7 58.8 33.4 – – –
25 5781-08-10-0-00 60.3 49.2 – – 11.1 20.6 44.5 79.4 73 39.7 – – –
32 5781-10-13-0-00 84.2 67.5 – 42.1 16.7 24.6 62.7 96.8 92.8 48.4 – – –
Tolerance for all dimensions ±0.2
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.4 83 21 62.5 – – – 29.4 95.2 43.7 111 5 –
25 5781-08-0-0-00 105 39.7 107.5 29 87 – – – 35.1 127.2 43.7 111 5 –
32 5781-10-13-0-00 120 48.4 120 30 99.5 – – – 31 144.7 43.7 111 5 –
Features
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types
• D4S03 - NG10
D4S06 - NG25
D4S10 - NG32
D4S10-9DC
D4S 9 B
Seat Nominal Subplate Pilot Cap Sleeve Spool Spring Switching Solenoid Design Seals Options
valve size mounting connec- version type type voltage series
ISO 6264, tion
Y1 port G¼"
Code Nominal size Code Options
03 NG10 omit Standard
06 NG25 Cover for end
013
10 NG32 position control
General
Size NG10 NG25 NG32
Mounting interface Subplate mounting according to ISO 6264
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 2.7 4.5 6.0
Hydraulic
Operating pressure [bar] Ports A, B up to 350; Port Y 140 (with VV01)
Nominal flow [l/min] 180 360 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
110 at 50 Hz 230 at 50 Hz
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
120 at 60 Hz 240 at 60 Hz
6
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
in rush [W] 32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Y1 de-energized open
X-Y
X Z Y Z Y
Z1
VV01
de-energized closed
AZ
Z Y
AA AB
A-X B-Y
X A B Y Z1
Selection of Cartridges 6
Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet B/C
Z Z Z Z Z Z
B B B B B B
A A A A A A
1 : 1.05 1 : 1.05 1 : 1.05 1 : 1.67 1 : 1.67 1 : 1.67
AA = 0.95 AC AA = 0.95 AC AA = 0.95 AC AA = 0.6 AC AA = 0.6 AC AA = 0.6 AC
AB = 0.05 AC AB = 0.05 AC AB = 0.05 AC AB = 0.4 AC AB = 0.4 AC AB = 0.4 AC
15° chamfer 15° chamfer 45° chamfer 45° chamfer 45° chamfer 45° chamfer
orifice safety spool throttle spool
NG ISO-code X1 X2 X3 X4 X5 X6 X7 Y1 Y2 Y3 Y4
10 6264-06-09-*-97 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9
25 6264-08-13-*-97 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73 39.7 6.4
32 6264-10-17-*-97 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8
NG ISO-code B1 B2 H1 H2 H3 L1 L2 D1 D2 D3 t1 D4 t2 D5 D6
10 6264-06-09-*-97 87.3 33.35 83 21 45 29 94.8 15 7 7.1 8 M10 16 10.8 17
25 6264-08-13-*-97 105 39.7 107.5 29 69.5 34.7 126.8 23.4 7.1 7.1 8 M10 18 10.8 17
32 6264-10-17-*-97 120 48.4 120 30 82 30.6 144.3 32 7.1 7.1 8 M10 20 10.8 17
with without
Y1 manual manual
override override
D4S..-......11/12
VV01 Solenoid energized:
Flow from A-B or B-A
Solenoid de-energized:
Z1 D4S blocked
D4S
6
X A B Y
Y1
cap
body version
series D4S
X A B Y
Y1
cap
body version
series D4S
Note:
Stroke limiter not for use with D4S03, vent valve VV01, shuttle valve and positon control.
34.2
Ø30.5
6
For other plugs see chapter 2, "Accessories"
access06.INDD CM 18.02.15
content07.indd CM 23.02.15
Attention:
The adjustment of the position control is factory set
and sealed. Replacement and repairs can only be
undertaken by the manufacturer.
Z1DWA02E
Technical Features
• Shut-off sandwich valve NG06
• Inductive position control optional
7
Z1DW*E without inductive position control
General
Design Directional spool valve, sandwich type
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] 0...+60
MTTFD value [years] 150
Weight [kg] 1.8 (1 solenoid), 2.3 (2 solenoids) w/o position control
[kg] 2 with position control
Hydraulic
Max. operating pressure [bar] P, A B: 350 ; T: 210
Fluid Hydraulic oil in accordance with DIN 51524
Fluid temperature [°C] -20…+70 (NBR: -25…+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 50
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 32 ; De-energized: 40
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage
Code
[V]
K
12 V =
J
24 V =
U
98 V =
G
205 V =
7
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Z 1 D W W
Sandwich Size Wet pin Body Spool Spool Seals Solenoid Connector Manual Position
Design
plate, DIN NG06 solenoid type position voltage as per EN override control series
Shut-off CETOP 03 175301-803, option (not required
valve NFPA D03 without plug for ordering)
(please order
plug separately)
A 01 K
P A B T Code Manual override
P‘ A‘ B‘ T‘
Standard valve with
omit
manual override
A 02 C 1)
7
without manual
T 3)
P A B T override
P‘ A‘ B‘ T‘
A 02 E
Code Voltage
P A B T K 12 V =
P‘ A‘ B‘ T‘
J 24 V =
U 2) 98 V =
G
A 02 K
G 2) 205 V =
P A B T
B 37 B Code Seals
N NBR
V FPM
1
2
Us 18...42 V
Out B: normally open
7
3 0V
4 Out A: normally closed
5 Earth ground
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the spring is reached (above 75 % spool stroke).
offset position (below 25 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
The switch can only be located on the opposite side of the solenoid for direct operated valves.
Please order plug M12 x 1 separately (see accessories, plug M12x1; order no.: 5004109).
The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.
T-T' T-T'
Spool Symbol A-A' A'-A B-B' B'-B T-T' P-P' B-T
Start position End position
P‘ A‘ B‘ T‘
G
A02E 5 5 5 5 1 — — 1 —
P A B T
P‘ A‘ B‘ T‘
G
A01K 5 5 5 5 1 — — 1 —
P A B T
B37B 2 2 4 4 — 3 1 1 6
Flow curves
Shift limits
350
Pressure [bar]
300
37 01/02
250
200
150
100
50
0
0 10 20 30 40 50 60
Flow [l/min]
Z1DW Standard
B, E -style K -style
50
50
A P B A P B
Ø5.5 Manifold side Ø5.5 Manifold side
91.5 56 134.5 56
160 93 160 93
T T
A B A B
Solenoid is freely turnable. Solenoid is freely turnable.
P P
C -style
7
Valve side
50
A P B
Ø5.5 Manifold side
134.5 56
226 93
T
A B
Solenoid is freely turnable.
P
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
50
A P B
Ø5.5 Manifold side 46
91.5 86
254 93
T
A B Solenoid and position control
are freely turnable.
P
K -style
Valve side
7
50
A P B
Ø5.5 Manifold side 46
134.5 86
254 93
T
A B
Solenoid and position control
are freely turnable.
P
Surface finish
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Attention: The adjustment of the position control is factory set and sealed. Replacement and repairs can
only be undertaken by the manufacturer.
1) Please order plug M12 x 1 separately (see accessories, plug M12x1; order no.: 5004109).
Function
PT... pressure is relieved from P to T.
TT... pressure pre-loading in T.
RDM2 Example PT
Features
• The direct operated, cushioned piston design results
in fast response, low leakage and minimal hysteresis.
• Pressure settings:
bar 25, 64, 160, 210, 350 for RDM2,
bar 19, 50, 100, 150, 210 for RDM3.
• Adjustment modes:
- Hexagon socket B A
- Cylinder lock
- Turning knob
• Gauge port RDM2
7
Ordering code
RD M V
Pressure range
Code RDM2
02 1.5 to 25 bar
06 1.5 to 64 bar
16 3 to 160 bar
21 3 to 210 bar
35 5 to 350 bar
Code RDM3
01 1.5 to 19 bar
05 1.5 to 50 bar
10 3 to 100 bar
1) NG06 only, max. 160 bar.
2) Standard in housing. 15 3 to 150 bar
3) NG06 only. 21 3 to 210 bar
Technical data
General
Series RDM2 RDM3
Size NG06 NG10
Mounting interface ISO 4401
Weight [kg] 1.3 2.6
MTTFD value [years] 150
Ambient temperature [°C] -20...+60
Hydraulic
Max. operating pressure P, A, B [bar] 350 315
T [bar] 50 10
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
Max. flow [l/min] 40 80
Performance curves
RDM2 02 RDM2 06
7
RDM2 16 RDM2 21
RDM2 35
All characteristic curves measured with HLP46 at 50 °C.
RDM3 01 RDM3 05
RDM3 10 RDM3 21
RDM3 15
RDM*TT
RDM2
7 RDM3
Features
• The valve bodies of the Parker Manapak valve series RM6
RM are made of steel.
• The pressure can be set by hexagon socket screw
(RM4), hexagon socket screw or knob with cylinder lock
(RM6).Piloting results in a flat p/Q performance curve.
• Piloting results in a flat p/Q performance curve.
• The orifices located in the main spool limit the pilot oil
flow.
Schematics
RM6
RM4-NG16
RM6-NG25
(only PT)
Technical data
General
Design Pilot operated pressure relief valve
Actuation hydraulic
Size NG16 NG25
Mounting interface ISO 4401
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 4.9 5.9
Hydraulic
Max. operating pressure [bar] 350
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
RM UK.INDD CM 30.03.15
RM4 S V HT
Code Connection
PT P to T
AT A to T
BT B to T
RM6 PT V
7
Pressure Connection Pressure Adjustment Seal Design
relief valve P to T range FPM series
NG25 (not required
for ordering)
RM UK.INDD CM 30.03.15
300 20
250 25 spring
200
10
150
07 spring
100
0
0 100 200 300
50 Min. Flow [l/min]
setting
0
0 100 200 300
Flow [l/min]
RM6
RM UK.INDD CM 30.03.15
RM4
Adjustment code S
RM UK.INDD CM 30.03.15
RM6
Adjustment Code S
Adjustment Code L
RM UK.INDD CM 30.03.15
Features
• High flow capacity ZDV-P01 ZDV-B02
• Pressure function in P, A, B or A + B
• Sizes
ZDV01 - NG06 (CETOP 03)
ZDV02 - NG10 (CETOP 05)
ZDV-B02
Ordering code
7 ZDV S0 D
Technical data
General
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight 1 cartridge [kg] 1.6 3.0
2 cartridges [kg] 2.5 3.7
Hydraulic
Max. operating pressure [bar] 350 (ZDV-ABS 315) 315
Nominal flow [l/min] 80 140
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt ] / [mm2/s] 20 ... 400
recommended [cSt ] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
p [bar]
300 300
250 250
200 200
150 150
100 100
50 50
p min p min
0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
Q [l/min] Q [l/min]
ZDV-P/A/B/AB02 ZDV-ABS02
300 300
p [bar]
p [bar]
250 250
200 200
150 150
100 100
50 50
p min p min
0 0
0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140
Q [l/min] Q [l/min]
ZDV01
120 (Type AB, ABS) Seal kit
max. 62.5 96 (Type P, A, B) max. 62.5
Seal Order code
5.3
7.5
1 098-91182-0
T 5 098-91183-0
=
Complete cartridge
32.5
46
31
A B AF5 Pressure stage Order code
=
P 1 098-91116-0
AF17
6 5 098-91117-0
AF27
40.4 39.9
(30 Nm)
Type P+A+B
40
23
Type AB+ABS
49
31
31
7 ZDV02
Seal kit
Seal Order code
1 098-91076-0
5 098-91077-0
Complete cartridge
Pressure stage Order code
1 098-91116-0
5 098-91117-0
ZDV01
ZDV02
Funtion
These valves are "normally open" devices that allow
fluid to flow through the controlled port during their
Example PP
non-actuated or "at rest" condition. When downstream
pressure exceeds the value set by the spring force, the
control piston moves off its seat, closing off the flow path
and thus reducing the fluid passing through from the main
system. The cushioned piston modulates to maintain the
preset pressure in this branch of the hydraulic circuit. If,
due to external forces, the pressure continues to rise in
this branch circuit, the piston will keep moving against B A
the spring force allowing fluid to be drained to the tank,
thereby limiting maximum pressure to the valve's setting.
Features
• 3-way design for pressure relieving of the secondary side
• The direct operated, cushioned piston design results
in fast response, low leakage and minimal hysteresis.
7 • Reduced pressure in the 'P', 'A' or 'B' port.
• Pressure settings:
Schematics
PRDM*AA
25, 70, 160, 210, 350 bar for PRDM2,
19, 50, 100, 150, 210 bar for PRDM3.
• Gauge port
• PRDM2 - NG06 (CETOP 03)
PRDM3 - NG10 (CETOP 05)
PRDM*BB
Ordering code
PRD M V
Pressure range
Code PRDM2
02 up to 25 bar
06 up to 64 bar
16 up to 160 bar
21
35
up to 210 bar
up to 350 bar 7
Code PRDM3
01 up to 19 bar
05 up to 50 bar
10 up to 100 bar
15 up to 150 bar
21 up to 210 bar
1) NG06 only.
Technical data
General
Series PRDM2 PRDM3
Size NG06 NG10
Mounting interface ISO 4401
Ambient temperature [°C] -20...+60
Weight [kg] 1.3 2.6
MTTFD value [years] 150
Hydraulic
Max. operating pressure P, A, B 350 315
T [bar] 50 50
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
PRDM2 02
PRDM2 06
PRDM2 16/21
PRDM2 35
PRDM3 01
PRDM3 05
PRDM3 10
7
PRDM3 15
PRDM3 21
240
Setting pressure pe [bar]
210
180
150
120
90
60
Pe min
30
0
40 30 20 10 0 10 20 30 40 50 60 70 80
(T P’) Flow rate Q [l/min] (P P’)
All characteristic curves measured with HLP46 at 50 °C.
PRDM UK.INDD CM 30.03.15
PRDM2
46
40
2.5
169 (CodeS) SW5
Gauge port G1/4
223 (Code L) 20
202 (Code K)
83
69
40.5
5.5
P
A B
32.5
ø38
31
46
PRDM3
7 65
50
50
17 54±0.1 Ø6.6
9.9
46±0.1
T T
65
A B
P
3.4 90
126
215 (Code S)
266.2 (Code L) 20
Features
• The valve bodies of the Parker Manapak valve series
PRM are made of steel.
PRM6
• The control pressure range can be set by hexagon
socket screw (PRM4), knob, or knob with cylinder lock
(PRM6).
• Pressure gauge/measuring connections are available
in the valve body.
• Piloting results in a flat p/Q performance curve.
• PRM4 - NG16 (CETOP 07)
PRM6 - NG25 (CETOP 08)
P Y
PRM4
Technical data 7
General
Series PRM4 PRM6
Size NG16 NG25
Mounting interface ISO 4401
Ambient temperature [°C] -20...+60
Weight [kg] 5.0 5.6
MTTFD value [years] 75
Hydraulic
Max. operating pressure [bar] 350 250
Pressure reduction in channel P, A, B P, A
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
PRM 4 S V HT
PRM 6 V G
7 for ordering)
PRM4PA
PRM6AP
PRM4PB
PRM6
PRM4
Adjustment code S
PRM6
Adjustment code L
Adjustment code K
Features
• High flow capacity
• Pressure function in P, A or B
• With integral return flow check valve ZDR-P01 ZDR-B02
• Sizes:
ZDR01 - NG06 (CETOP 03)
ZDR02 - NG10 (CETOP 05)
ZDR-B02
7 Ordering code
ZDR S0 D
Technical data
General
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight ZDR-P [kg] 1.6 2.9
ZDR-AR / BR [kg] 1.8 3.0
Hydraulic
Max. operating pressure [bar] 350 (ZDR-AR / BR 315) 315
Nominal flow [l/min] 80 120
Pilot oil [l/min] 0.3 0.3
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
ZDR-P/AR/BR02
ZDR01
120 (type AR, BR) Seal kit
109 (type P) max. 50.5
Seal Order code
1 098-91184-0
7.5
T 5 098-91185-0
=
Complete cartridge
32.5
A B
46
31 AF5
Pressure stage Order code
AF17
=
P 1 098-91102-0
6 5 098-91103-0
AF27
M G1/4” 40.4 52.9 (30 Nm)
(ZDR-P01)
Type P
40
24
Type AR+BR
40
16
7
ZDR02
M G1/4” (ZDR-P02-...) Seal kit
116
max. 50.5 58 max. 50.5 Seal Order code
6.5 1 098-91082-0
5 098-91083-0
12
Complete cartridge
22.5
P
29.5
46
T T
5 098-91103-0
10.5
AF27
31 54 (30 Nm)
Type P+AR
Type BR
48.7
AF5
50
AF17
1.3
ZDR01
Pressure reducing in P
with pressure gauge port M
Series Order No.
M
ZDR-P01-1-S0-D1 098-91179-0
ZDR-P01-5-S0-D1 098-91211-0
A P T B
Pressure reducing in A
with check valve
Series Order No.
ZDR-AR01-1-S0-D1 098-91212-0
ZDR-AR01-5-S0-D1 098-91213-0
A P T B
Pressure reducing in B
with check valve
Series Order No.
ZDR-BR01-1-S0-D1 098-91214-0
ZDR-BR01-5-S0-D1 098-91215-0
A P T B 1 = 7 … 70 bar
5 = 7 … 315 bar
ZDR02
PRPM*AA PRPM*BB
7 Ordering code
PRP M K V
General
Design Pilot operated proportional pressure reducing valve
Construction Sandwich type
Operation Proportional solenoid
Size NG06 NG10
Mounting interface ISO 4401
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 75
Weight [kg] 2.0 3.2
Hydraulic
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Max. operating pressure [bar] 350
Reduced nom. pressure [bar] 100; 200; 350
Max. flow [l/min] 60 60
Pilot flow see performance curves
Filtration ISO 4406 (1999); 18/16/13
Resolution [mA] 1 mA
Repeatability [%] ≤1 (with optimal dither signal)
Hysteresis [%] ≤4 (with optimal dither signal)
Electrical
Solenoid Proportional solenoid, wet-pin push type, pressure tight
Duty ratio
Protection class
[%] 100 ED
IP65 in accordance with EN 60529 (with correctly mounted plug-in connector) 7
Supply voltage [V] 12 (1320 mA)
Solenoid connection Connector as per EN 175301-803
Amplifier PCD00A-400
p red. [bar]
300
250
150
50
0
0 10 20 30 40 50 60 70 80 90 100
l [%]
100
0
0 50 100 150 200 250 300 350
pE [bar]
PRPM2AA*, BB**
PRPM2PP*
PRPM3AA*, BB**
7
PRPM3PP*
LCM3
Ordering Code
LCM PP 02 V
Technical data
General
Series LCM2 LCM3
Size NG06 NG10
Mounting interface NFPA D03 NFPA D05
CETOP 03 CETOP 05
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Hydraulic
Max. operating pressure [bar] 350 350
Pressure differential [bar] 10 10
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
LCM UK.INDD CM 30.03.15
Features
• 2-way or 3-way pressure compensators
• Standard pressure differential 5 bar
• Adjustable differential (2...5 bar) and 10 bar - optional SPC01 (2-way)
• SPC01 - NG06 (CETOP 03)
SPC02 - NG10 (CETOP 05)
SPC03 - NG16 (CETOP 07)
SPC06 - NG25 (CETOP 08)
SPC01/02
SPC 1 C 5 A
Direct operated Nominal Function Pressure Circuit Load Steel Design Seal
pressure size differential type sensing body series
compensator port
SPC01 SPC02
Type Model no. Order no. Type Model no. Order no.
SPC 01 01 041C5A 026-42583-0 SPC 02 01 041C5A 026-42589-0
3-way compensators with 3-way compensators with
SPC 01 01 051C5A 026-42584-0 SPC 02 01 051C5A 026-42590-0
shuttle valve P-A/B shuttle valve P-A/B
SPC 01 01 101C5A 026-42585-0 SPC 02 01 101C5A 026-42591-0
2-way compensators with 2-way compensators with
SPC 01 11 051C5A 026-42560-0 SPC 02 11 051C5A 026-42566-0
shuttle valve P-A/B shuttle valve P-A/B
SPC03/06
SPC C B
SPC01
Flow regulation example: 2-way pressure
compensator at Dp = 5 bar
7
SPC02
Flow regulation example: 2-way pressure
compensator at Dp = 5 bar
SPC03
Flow regulation example: 2-way pressure
compensator at Dp = 5 bar
7
SPC06
Flow regulation example: 2-way pressure
compensator at Dp = 5 bar
7
3-way pressure compensator
SPC01 SPC02
SPC03 SPC06
4 screws M10 x 120 ISO 4762-12.9, 6 screws M12 x 140 ISO 4762-12.9
2 screws M6 x 120 ISO 4762-12.9 Order no. BK522
Order no. BK521
80
60
7
172
208
T P X T P Y
92
A B
116
Y
X
A B
Features
• Two types of metering needle design can be selected
when ordering FM2 and FM3 valves to achieve the
throttle characteristics required to suit the application.
• Large bypass check valves allow high flow at low pres-
sure drop.
• NG06 - FM2 (CETOP 03)
NG10 - FM3 (CETOP 05)
NG16 - FM4 (CETOP 07)
NG25 - FM6 (CETOP 08) 7
Technical data
General
Series FM2 FM3 FM4 FM6
Size NG06 NG10 NG16 NG25
Mounting interface NFPA D03 NFPA D05 NFPA D07 NFPA D08
CETOP 03 CETOP 05 CETOP07 CETOP 08
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.3 2.4 5.4 7.9
Hydraulic
Max. operating pressure [bar] 350 350 350 210
Max. Flow [l/min] 53 76 200 341
Opening pressure [bar] 0.3 0.3 0.3 0.3
Meter-in throttle • • • —
Meter-out throttle • • • •
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
FM UK.INDD CM 30.03.15
FM DD V
Code Needle
omit Standard conical
Fine, cylindrical
D Hollow bored
with V notch
A two-stage needle provides fine adjustment in the lower flow range with 3 adjustment rotations. After 3 more rotations,
the valve is completely open.
7 Design "D"
A cylindrical needle with a V notch allows the fine adjustment over the entire setting range.
FM 4 DD V HT
Code Description
T Meter-in
F Meter-out
FM 6 DD K V
FM UK.INDD CM 30.03.15
7
FM3 standard needle FM3D needle with V notch
FM UK.INDD CM 30.03.15
FM2
Adjustment code K
Meter-in
Valve side
Manifold side
Meter-in or meter-out
A functional change is achieved by rotating
the mounting position of the valve 180°
about the longitudinal axis (A-B).
Meter-out
Adjustment code S
(Meter-out shown)
Note:
The O-ring plate (with O-rings) for sealing the con-
necting surface of the manifold side is included. The
O-ring and positioning pin are always mounted on the
manifold side.
FM UK.INDD CM 30.03.15
FM3
Adjustment code K
Meter-in
Meter-in or meter-out
A functional change is achieved by rotat-
ing the mounting position of the valve 180º
about the transverse axis (P).
Meter-out
Adjustment code S
(Meter-out shown)
Note:
The O-ring plate (with O-rings) for sealing the con-
necting surface of the manifold side is included. The
O-ring and positioning pin are always mounted on the
manifold side.
FM UK.INDD CM 30.03.15
FM4
Meter-in Meter-out
FM UK.INDD CM 30.03.15
FM6
Meter-out
Adjustment: knob
FM UK.INDD CM 30.03.15
Features
ZRD-ABZ01 ZRD-AA02
• High flow capacity
• Various functional arrangements
• ZRD01 - NG06 (CETOP 03)
ZRD02 - NG10 (CETOP 05)
ZRD-AA02
7
Ordering code
ZRD S0 D
Technical data
General
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight 1 cartridge [kg] 1.2 2.8
2 cartridges [kg] 1.3 2.9
Hydraulic
Max. operating pressure [bar] 350 315
Nominal flow [cSt] / [l/min] 80 160
Leakage [cSt] / [l/min] 0.1...0.2 (at closed throttle) 0.1...0.2 (at closed throttle)
Opening pressure [bar] 0.7 0.7
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
ZRD*02
7
ZRD*02
Seal kit
Seal Order code
1 098-91098-0
5 098-91099-0
Complete cartridge
Order code 098-91120-0
O-ring plate
Order code S16-85742-0
ZRD*01
ZRD*02
Features
• The valve bodies of the Parker Manapak valve series
CM are made of steel.
• Eight options for the arrangement of the check valve
in the body offer a multitude of uses for hydraulic
switching.
• The function can be changed by turning the valve.
• CM2 - NG06 (CETOP 03)
CM3 - NG10 (CETOP 05)
Ordering code
CM V 7
Check Nominal Port Seal Design
valve size FPM series
(not required
for ordering)
CM UK.INDD CM 16.04.15
Technical data
General
Series CM2 CM3
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 0.9 1.7
Hydraulic
Max. operating pressure [bar] 350 350
Max. flow [l/min] 53 76
Opening pressure [bar] 0.3 0.3
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity , permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Schematics
The valve side is shown at the top of the symbols, the manifold side with channel designation is shown at the bottom.
CM UK.INDD CM 16.04.15
CM2
Bottom view1)
Front side
Top view 7
Note:
The O-ring plate for sealing the connecting surface of
the manifold side is included. The O-ring plate and the
positioning pin are always mounted on the manifold
side.
CM UK.INDD CM 16.04.15
CM UK.INDD CM 16.04.15
CM3
Bottom view1)
Front side
Top view
Note:
The O-ring plate for sealing the connecting surface of
the manifold side is included. The O-ring plate and the
positioning pin are always mounted on the manifold
side.
CM UK.INDD CM 16.04.15
CM UK.INDD CM 16.04.15
Features
• Leakage-free seat
• High life time
• Opening pressure 0.5 bar
• ZRV01 - NG06 (CETOP 03)
ZRV02 - NG10 (CETOP 05) ZRV-P02 ZRV-P02
ZRV-P02
Ordering code
ZRV
Technical data
General
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 0.7 2.0
Hydraulic
Max. operating pressure [bar] 350 315
Nominal flow [l/min] 40 100
Opening pressure [bar] 0.5 0.5
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
7
ZRV*02
ZRV01
Seal kit
Seal Order code
NBR SK-CM2-10
FPM SK-CM2-V-10
7
ZRV02
Seal kit
Seal Order code
NBR SK-CM3-10
FPM SK-CM3-V-50
ZRV01
ZRV02
Ordering code
Without pre-opening
CPOM V 7
Hydraulically Size Poppet Opening Seal Design
operated style pressure FPM series
check valve (not required
for ordering)
pilot ratio 3 : 1
Code Size Code Pressure Size
2 NG06 omit 1.0 bar NG06/10/25
3 NG10 25 2.5 bar NG06
6 NG25 50 5.0 bar NG06
70 7.0 bar NG06
Code Connection
AA only A
BB only B
DD A and B
With pre-opening
CPOM 4 HT V
Code Connection
AA only A
BB only B
DD A and B
Technical data
General
Series CPOM2 CPOM3 CPOM4 CPOM6
Nominal size NG06 NG10 NG16 NG25
Mounting interface ISO 4401
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.8 4.0 7.65 9.5
Hydraulic
Max. operating pressure [bar] 350 350 350 210
Opening pressure [bar] 1.0 0.8 2.0 0.4
Opening ratio 1:3 1:3 1 : 13 1:3
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Schematics
CPOM2 / CPOM3 CPOM4 / CPOM6
CPOM2
111.5
34
7
T
A B
45
P
130
Valve side
40
22
Manifold side
3.5
7
CPOM3
145
45.5
12
A B
70
T T
165
Valve side
V SK-CPOM3-V-11
Note:
The O-ring plate for sealing the connecting surface of Manifold side
the manifold side is included. The O-ring plate and the
positioning pin are always mounted on the manifold
side.
CPOM4 155
27.5 34.1
7 10.5
10
T P X
90
A B
Y
42
50
174
Valve side
79.7
53
Seal kit CPOM4
Seal Order code
V SK-CPOM4HTV
Manifold side
7
CPOM6 168
10
11.5
T P Y
115
X A B
51.5
200
Valve side
V SK-CPOM6-V-20
Note:
The O-ring plate for sealing the connecting surface of Manifold side
the manifold side is included. The O-ring plate and the
6.2
ZRE-A02
Ordering code
ZRE
7 Check valve
pilot oper-
Pressure
control
Nominal
size
Design
series
Seal
ated
Code Pressure control Code Seal
A Blocked in A 1 NBR
B Blocked in B 5 FPM
AB Blocked in A and B
Code Design series
Code Nominal size D NG06
01 NG06 E NG10
02 NG10
Ordering code details see end of chapter.
Technical data
General
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.2 3.1
Hydraulic
Max. operating pressure [bar] up to 350 315
Nominal flow [l/min] 60 120
Opening ratio (pilot cone / main cone) 1:6 1:6
Opening pressure [bar] 1.2 2.0
Leakage on request
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
ZRE UK.INDD CM 30.03.15
Dimensions
96
ZRE*01 Seal kit
8 48 8
Seal Order code
5.3
7.5
1 098-91088-0
T 5 098-91089-0
7
23
32.5
31
46
A B
P
6
26.7 40.4
40
25
A B
10.5
46
70
T T
50
35
ZRE*01
ZRE*02
Features
• Controlled movement loads
• Load holding via leak-free poppet valve
• Secondary relief protection for the actuator
• ZNS*01 – NG06 (CETOP 03)
ZNS*02 – NG10 (CETOP 05)
ZNS-B01
Ordering code
ZNS S0 D
Counterbal-
ance valve
Pressure
control
Nominal
size
Pressure
stages
Hexagon
screw with
Design
series
Seal 7
lock nut
Code Pressure control Code Seal
A in A 1 NBR
B in B 5 FPM
AB in A and B
Technical data
General
Size NG06 NG10
Mounting interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
Mounting position unrestricted
Ambient temperature [°C] -20...+60
Weight 1 cartridge [kg] 1.3 1.6
2 cartridges [kg] 3.0 3.9
Hydraulic
Max. operating pressure [bar] 350 315
Pressure stages [bar] 175, 350
Pilot ratio 4.5 : 1
Leakage on request
Nominal flow [l/min] 60 120
Opening pressure [bar] 0.3 0.3
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
ZNS UK.INDD CM 30.03.15
40
30
20
10
0
0 10 20 30 40 50 60
Q [l/min]
ZNS*02
40
p [bar]
7
30
20
10
0
0 20 40 60 80 100 120
Q [l/min]
ZNS*01
ZNS*02
NG06 NG16
Code: ISO 4401-03-02-0-94 Code: ISO 4401-07-06-0-94
NG10
Code: ISO 4401-05-05-0-94
min. 72
54*
50.8
37.3
NG25
7
27
16.7 Code: ISO 4401-08-07-0-94 (Port diameter acc. to NFPA)
3.2
P
6.3
21.4
A B
32.5
max. 75
min. 58
46*
Mounting Torques
Parker sandwich valves can be installed as desired. Each The mounting screws or studs must be tightened with the
has a mounting pattern, whose dimensions correspond prescribed tightening torque so that safety and proper
to the following standards. seal are ensured.
ISO 4401 See chapter 12 “Accessories“ for BK bolt kits and TK tie
DIN 24430 rod kits.
CETOP RP121
NFPA Threads length
Threads M5 M6 M10 M12
Mounting screws
thread length 1.5 x Ø thread
Cylinder head bolts as per ISO 4762-12.9, or studs as
per DIN 835 10.9 with cylindrical nuts are used to mount
the height stacking Manapak sandwich valves.
Bolt kits and tie rods see chapter 12, "Accessories".
Information07.INDD CM 30.03.15
content08.INDD CM 16.04.15
Description Description
Depending on valve function and design, power ports A AA Area, which is subjected to the pressure at port A
and B can be used for inlet or outlet. AB Area, which is subjected to the pressure at port B
The control port C is the connection between cover and AC Area, which is subjected to the pressure at port C
cartridge unit.
Control ports
X control oil connection, inlet
Y control oil connection, outlet
Further control ports
Z1 control oil connection, preferred inlet
Z2 control oil connection, preferred outlet
Area representation
Design representation
intro08.INDD CM 16.04.15
Z1
d7
m2
m3
22.5°
d5
X Y X Y
m1
b1
b1
d5
m1
m4
m2
d7
d6
Z2
Z2
15°
d1 Required surface finish:
1 2
1 = √ Rmax16, 2 = √ Rmax8
t7
t5
2
t4
t1
t2
d2 15°
d4
1
t8
8
t3
t3 and t5
d3 length of fit Cartridge manifold block series CB see chapter 12.
Features
CE C*B
• Installation cavity and mounting pattern according to
ISO 7368
• 5 poppet shapes
• 5 poppet springs
• Optional seal between ports B and C
• Cover with adjustable stroke limitation
• Cover with mounting pattern for pilot valve assembly
• Combinations for complex functions
• Normally open cartridge (CE*F*)
C*A C*C
normally open
1:1
AA = AC
1 : 1.67
AA = 0.6 AC
1 : 1.04
AA = 0.96 AC
1 : 1.67
AA = 0.6 AC
8
AB = 0.4 AC AB = 0.4 AC
dampening poppet
2 1 3
3 1 4 3 1 2 4 3 2 1 4
X Z1 C Z2 Y X Z1 C Z2 Y X Z1 C Z2 Y X Z2 C Z1 Y
C*F C*G C*C C*C
1 : 1.04
AA = 0.96 AC
C
normally closed
Cartridge
valve CP
a B
CE
1) Only for spring S, T and U. Not for poppet code 01 (NG16 to NG63).
8
2) Only with spring code L, only with closed bottom.
3) Not for NG80 and NG100.
4) Orifice size in 1/10 mm, eg. 1.2 mm orifice - code 12. Thread size 1/16 NPTF.
CP 07
Technical data
General
Design type 2-way slip-in cartridge valves according to ISO 7368
Actuation hydraulic
Mounting position unrestricted
Ambient temperature [C°] -20....+60
MTTFD value [years] 150
Nominal size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Weight cartridge [kg] 0.3 0.6 1.1 1.7 3.7 7.1 12.8 27
Hydraulic
Operating pressure without pilot valve [bar] 420
port A, B, X, Z1, Z2 [bar] 350, 420 (depending on pmax of pilot valves)
port Y [bar] According to pilot system, max. 350 (depending on pmax of pilot valves)
Nominal flow at ∆p 5 bar poppet 01, 04, 07 [l/min] 250 450 900 1350 1800 3600 5250 8000
poppet 08 [l/min] 230 400 800 1250 1625 3400 5000 7500
Pilot volume requirement at poppet 01 [cm3] 2.0 6.5 10.2 17.4 34.5 77.4 190.1 342.6
at poppet 04 2.0 6.5 12.2 20.3 39.4 94.6 190.1 363.4
at poppet 07 2.0 6.5 10.2 17.4 34.5 77.4 — —
at poppet 08 2.0 7.4 15.3 23.2 49.2 111.8 217.3 415.3
Poppet 01 / 07 spring: L = 0.1 N = 0.5 S = 1.6 T = 2.5 U = 4.0
Opening pressure flow direction A → B [bar]
Poppet 04 / 08 spring: L = 0.2 N = 0.9 S = 2.7 T = 4 U = 6.6
Poppet 01 / 07 not possible
Opening pressure flow direction B → A [bar]
Poppet 04 / 08 spring: L = 0.3 N = 1.3 S = 4.0 T = 6.3 U = 10.0
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [C°] -20...+70 (NBR: -25...+70)
Viscosity, permitted [mm2/s] 20...400
recommended [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
C A A
1
For orifice recommendations, bolt and seal kits see
"Accessories" in this chapter. X Z1 C Z2 Y
Orifice position
Dimensions
NG16 to NG63 NG80 to NG100
Gauge port G¼" Gauge port G¼"
L
8 X Orifice Y X Orifice Y
Z1
Z1
B
X Y X Y
Z2
Z2
B
B
C B N
8
max.L 2
Gauge port
L1
X Y
Orifice
Z1
1cm
B
M16
X Y
Z2
4 B
1cm
max.L2
L2
8 Gauge port
L1
L1
Gauge port
X Y X Y
Orifice
Orifice
Z1
Z1
X Y
B
X Y
Z2
Z2
4 B 4 B
C C A
1 2 3 4
Cover Nominal Cover Without Orifice / Seal Design
size for pilot auxilliary choke series
system function (not required
mounting for ordering)
Code Size
Code Seal
016 NG16
N NBR
025 NG25
V FPM
032 NG32
040 NG40
050 NG50 Code Orifice
063 NG63 99 Without orifice, open
080 NG80 00 Plug
100 NG100 NG16 to NG40
P A B T
Attention:
3 1 2 4
For NG50 and larger:
If pilot system NG06 should be used, mount adapter plate X Z1 C Z2 Y
PADA 1007/A-B/B-A or PADA 1007/A-A/B-B (NG10 to NG50 to NG100
NG06) see "Accessories" in this chapter. P A B T
8
Dimensions NG16
Orifice thread
Size B L Gauge port Weight [kg]
1 2 3 4 5 6
NG16 79 1) 40 G¼" 1.0 M5 M5 M5 M5 M5 M5
NG25 85 45 G¼" 1.9 M5 M5 M6 M6 M6 M6
NG32 102 50 G¼" 2.9 M5 M5 M6 M6 M6 M6
NG40 125 60 G¼" 5.3 M5 M5 M6 M6 M6 M6
NG50 140 70 G¼" 8.5 M6 M6 M8 M8 M8 M8
NG63 180 85 G¼" 15.3 M6 M6 M8 M8 M8 M8
NG80 Ø 250 105 G¼" 34 1/16 NPT 1/16 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
NG100 Ø 300 120 G¼" 60 1/16 NPT 1/16 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
1) Width 65 mm.
C F
1 2 3
Pressure range
Code Code Orifice
[bar]
07 75 99 Without orifice, open
10 105
17 175
21 210 2 1 3
25 250
35 350 X Z1 C Z2 Y
Orifice position
Code Adjustment
S Hand knob (standard)
A Acorn nut with lead seal
L Cylinder lock
Dimensions
8
Orifice thread
Size B H L1 L2 max. L3 L4
C G
1 2 3 4
Pressure range
Code Code Orifice
[bar]
07 75 99 Without orifice, open
10 105 P A B T
17 175 2
21 210
25 250 3 1 4
35 350
X Z1 C Z2 Y
Orifice thread
Size B H L1 L2 max. L3 L4
Ordering code
C H N N
1 2 3 4
Attention:
For NG63, 80 and 100:
If pilot system NG06 should be used, mount adapter plate
PADA 1007/A-B/B-A or PADA 1007/A-A/B-B (NG10 to
NG06), see "Accessories" in this chapter.
For orifice recommendations, bolt and seal kits see
"Accessories" in this chapter.
Orifice position
8 Dimensions NG16
Orifice thread
Size B B1 H h h1 t Gauge port
1 2 3 4
NG16 65 – 125 85 76 27 G1/4 M5 M5 M5 M5
NG25 85 – 114 85 70 36.5 G1/4 M6 M6 M6 M6
NG32 102 – 132.5 85 56 47.5 G1/4 M6 M6 M6 M6
NG40 125 – 142 85 50 64 G1/4 M6 M6 M6 M6
NG50 140 – 147.5 85 60 72.5 G1/4 M8 M8 M8 M8
NG63 180 – 161 110 75 90 G1/4 M8 M8 M8 M8
NG80 Ø 250 119 215 120 94 122 G1/4 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
NG100 Ø 300 144 240 120 85 145 G1/4 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
Ordering code
C V A
1 2 3 4
X Z1 C Z2 Y
Dimensions
Orifice position
Section A-A
4 3
1 2
A T B P
H
8
X C Y
Z1
B
X Y
A A
Z2
4 L1
Orifice thread
Size B H L1
NG16 65 86.5 85 M5 M5 M5 M5
NG25 85 91.5 85 M5 M5 M5 M5
NG32 102 96.5 102 M5 M5 M5 M5
NG40 125 106.5 125 M6 M6 M6 M6
NG50 140 126.5 140 M8 M8 M8 M8
NG63 180 141 180 M8 M8 M8 M8
CE-C UK.INDD CM 16.04.15
C W A
1 2 3 4
Orifice position
Dimensions
Orifice thread
Size B H L1
NG16 65 40 77.5 M5 M5 M5 M5
NG25 85 45 85 M5 M5 M5 M5
NG32 102 50 102 M5 M5 M5 M5
NG40 125 60 125 M6 M6 M6 M6
NG50 140 70 140 M8 M8 M8 M8
NG63 180 85 180 M8 M8 M8 M8
Ordering code
R06M 4
Pressure Pressure Pilot oil Seal Design
range adjustment series
(not required
for ordering)
Dimensions
access08.INDD CM 16.04.15
Ordering code
RS06M 4
8
Dimensions
access08.INDD CM 16.04.15
RPDM2AT
Ordering code
RPDM2PT
RPDM 2 V
Pressure Pressure Pressure Solenoid Seal Design
adjustment relief range voltage FPM series
(not required
for ordering)
8
Code Adjustment Solenoid
Code
AT A to T voltage
PT P to T K 12 V, 2.3 A
X 16 V, 1.3 A
Pressure range
Code
[bar]
10 105
17 175
25 250
35 350
Dimensions
access08.INDD CM 16.04.15
ZUDB1AT*
ZUDB1PT*
Ordering code
ZUDB1 Z07
Seal Pressure Pressure Pressure
relief adjustment range
8
Code Seal Pressure range
Code
omit NBR [bar]
V FPM B 70
E 175
Code Pressure relief G 250
AT A to T K 350
PT P to T
Code Adjustment
Hexagon screw with
2
lock nut
61 Cylinder lock
access08.INDD CM 16.04.15
DSBA100 P07
access08.INDD CM 16.04.15
UR 06 M 4
72
16 Acorn nut
with lead seal
7.5 T
43.2
38
46
A B
P
Turning knob Hand knob
153.3 with key lock 26 142
144.5
US 06 M 4
T
43.2
38
46
A B
P
Turning knob
Hand knob
153.3 with key lock 26 142
144.5
access08.INDD CM 16.04.15
Ordering code
S06M 4
Pressure Pressure Pilot oil Seal Design
range adjustment inlet internal/ series
outlet internal (not required
for ordering)
Dimensions
access08.INDD CM 16.04.15
SVLA1006P07
ZSRA1PP0Z07
ZSRB1AA0Z07
access08.INDD CM 16.04.15
P A B T Valve side
P T H06-1044 NG06 30
G1/4 G1/4
P A B T Manifold side
P A B T Valve side
A B
H06-1039 NG06 30
G1/4 G1/4
P A B T Manifold side
P A B T Valve side
P
H06-504 NG06 30
G3/8
P A B T Manifold side 8
P A B T Valve side
T
H06-711 NG06 30
G3/8
P A B T Manifold side
P A B T Valve side
M
H06-1274 NG06 30
G1/4
P A B T Manifold side
P A B T Valve side
P A B T Manifold side
H06-1040 NG06 30
P A B T Valve side
P A B T Manifold side
Attention:
Details for cover-, sandwich- and adaptor plates see chapter 12.
access08.INDD CM 16.04.15
H06DO-1291 NG06 10
P A B T Manifold side
8
All ports can be equipped with orifices or plugs (1/16NPT)
Attention:
Details for cover-, sandwich- and adaptor plates see chapter 12.
access08.INDD CM 16.04.15
Size 16 25 32 40 50 63 80 100
Poppet 01 RK-45036369 RK-45036379 RK-45036392 RK-45036409 RK-45036421 RK-45036437 RK-35036449 RK-35036467
Poppet 04 RK-45036370 RK-45036380 RK-45036395 RK-45036406 RK-45036422 RK-45036436 RK-35036460 RK-35036468
Poppet 07 RK-35037531 RK-45036964 RK-45036965 RK-45036966 RK-45036967 RK-45036968 — —
Poppet 08 RK-45036368 RK-45036381 RK-45036391 RK-45036408 RK-45036424 RK-45036438 RK-35036459 RK-35036469
CE-sleeve RK-35038871 RK-35038872 RK-35038873 RK-35036403 RK-35036417 RK-25036432 RK-25036452 RK-25036470
CP-sleeve RK-35039384 RK-35039385 RK-35039386 RK-35039387 RK-35039388 RK-35039389 — —
Spacer ring RK-35036364 RK-35036375 RK-45036393 RK-35036402 RK-35036416 RK-35036435 RK-25036453 RK-25036471
Orifices
There are different orifices available to realize different
opening / closing velocities.
8 The control volume of each nominal valve size can be
found at the CE series.
Orifice kit Orifice kit, sorted by thread with different diameters, consisting of 2 pieces of each marked diameter
Ø 0.0 0.8 0.9 1.0 1.1 1.2 1.3 1.5 1.8 2.0 2.2 2.5 3.0
DK-M4 • • • • • • • • – • – – –
DK-M5 • • • • • • • • – • – – –
DK-M6 • • • • • • • • – • – – –
DK-M8 • – – • – • – • • • • • –
DK-M10x1 • – – • – • – • • • – • •
DK-1/16NPT • • • • • • • • – • – – –
DK-1/8NPT • – – • – • – • • • – • •
Orifice kits, thread with one defined diameter 20 pcs per box
Orifice kits of one size:
Ordering Code Examples
DK-M4-08 Þ 20 pcs, orifice size 0.8 mm
DK-M5-10 Þ 20 pcs, orifice size 1.0 mm
DK-M8-12 Þ 20 pcs, orifice size 1.2 mm
Support handle
Expanding collet
Ordering code
Valve size Order no.: Figure 1
CE016 * 090 4600 09779
CE025 * 090 4600 09780
CE032 * 090 4600 09781
CE040 * 090 4600 09782
CE050 * 090 4600 09783
CE063 * 090 4600 09784
CE016 to CE063 * 090 4600 09785
Ordering Code
Valve size Order no.: Figure 2 Figure 3 Figure 4
CE080 090 4600 10628
CE100 090 4600 10629
* CE/CP respectively
R25E RS25E
R*E
R E 1 S
Pressure Nominal Slip-in Pressure Adjust- Pilot oil Poppet Seal Design Spool
relief size mounting stages ment (pilot internal, spring series type
valve ISO 7368 drain external) (not required
for ordering)
RS*E
RS E 1 S W
Pressure Nominal Slip-in Pressure Adjust- Pilot oil Poppet Seal Switching Solenoid Without Options Design Spool
8
relief size mounting stages ment (pilot int., spring type plug series type
valve with ISO 7368 drain ext.) (not required
elec. un- for ordering)
loading
Code Seal
1) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply. N NBR
V FPM
R-RS_E UK.INDD CM 16.02.15
R*E
General
Nominal size NG16 NG25 NG32 NG40 NG50 NG63
Interface Slip-in mounting acc. ISO 7368
Mounting position as desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.2 3.5 4.9 8.0 13.7 22.8
Hydraulic
Max. operating pressure [bar] Ports A and X up to 350, Ports B and Y 30
Pressure stages [bar] 75, 105, 175, 210, 250, 350
Nominal flow [l/min] 220 500 950 1400 2300 4000
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
RS*E
General
Nominal size NG16 NG25 NG32 NG40 NG50 NG63
Interface Slip-in mounting acc. ISO 7368
Mounting position as desired, horizontal mounting preferred
8 Ambient temperature
MTTFD value
[°C] -20...+60
[years] 75
Weight [kg] 2.7 5.2 6.4 9.5 15.2 24.3
Hydraulic
Max. operating pressure [bar] Ports A and X 350, ports B and Y 30
Pressure stages [bar] 75, 105, 175, 210, 250, 350
Nominal flow [l/min] 220 500 950 1400 2300 4000
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
30
Pressure p [bar]
25
20
15
10
0
0 20 40 60 80 100
Nominal flow Q [%]
All characteristic curves measured with HLP46 at 50 °C.
Dimensions R*E
NG16 - NG32 NG40 - NG63 1)
Size H B L1 L2 L3 L4 L5 d1 d2 t
NG16 40 65 2) 32.5 – 114 125.5 117 32 25 56
NG25 47 85 42.5 – 102 114 105 45 34 71
NG32 50 102 51 – 95 106 97.5 60 45 85
NG40 106 125 62.5 66.5 106 144 110.5 75 55 105
NG50 141 140 70 74 106 144 110.5 90 68 121
NG63 155 180 90 94 106 144 110.5 120 90 155
Dimensions RS*E
NG16 - NG32 NG40 - NG63 1)
Size H B L1 L2 L3 L4 L5 L6 d1 d2 t
NG16 133 65 2) 32.5 – 114 125.5 117 117 32 25 56
NG25 137 85 42.5 – 102 114 117 105 45 34 71
NG32 143 102 51 – 95 106 117 97.5 60 45 85
NG40 196 125 62.5 66.5 106 144 117 110.5 75 55 105
NG50 231 140 70 74 106 144 117 110.5 90 68 121
NG63 246 180 90 94 106 144 117 110.5 120 90 155
Features
• TÜV certificate
• CE certification (module G) according to directive 97/23/EC
• Installation cavity and mounting pattern according to
ISO 7368
• 3 sizes, NG16 to NG32
• Remote control via port X
X Y
Detailed symbol
Ordering code
DSDU TÜV
Seals Pressure Type Pressure Desired opening
relief code stage pressure in bar
valve (please specify)
Ordering examples
DSDU 1078 E32E - 120 bar matches Qmax 550 l/min, opening pressure 120 bar
DSDU 1078 E32E - 150 bar matches Qmax 640 l/min, opening pressure 150 bar
Technical data
General
Size NG16 NG25 NG32
Interface Slip-in mounting according to ISO 7368
Mounting position as desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value
Weight
[years] 150
[kg] 2.2 3.5 4.9
8
Hydraulic
Max. operating pressure [bar] Ports A and X 350, B and Y depressurized
Pilot oil External / external
Adjustment pressure [bar] See ordering code
Nominal flow [l/min] See ordering code
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
p/Q curve
4 B
39.5
H1
X Y
8 B
NG H H1 B L
16 140 84 79 * 142
25 160 88 85 135
32 178 93 102 143
* Width 65 mm.
Features
• Pilot operated with proportional solenoid
• Continuous adjustment by proportional solenoid
• Optional mechanical max. pressure stage
• Cavity and mounting pattern according to ISO 7368
• 4 pressure stages
• 6 sizes, NG16 to NG63
Note
Port X only usable for remote vent function
Ordering code
RE E W 1 S 1 W
Prop. Nominal Slip-in Pressure Off-board Pilot oil Poppet Seal Normally Solenoid Without Options Design Spool
pressure size mounting stages electronics (pilot int., spring open plug series type
relief ISO 7368 drain ext.)
valve
8 Technical data
General
Nominal size NG16 NG25 NG32 NG40 NG50 NG63
Interface Slip-in mounting acc. ISO 7368
Mounting position as desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.7 5.2 6.4 9.5 15.2 24.3
Hydraulic
Max. operating pressure [bar] Ports A and X 350, ports B and Y 30
Pressure stages [bar] 105, 175, 250, 350
Nominal flow [l/min] 220 500 950 1400 2300 4000
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (proportional solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K X
Supply voltage [V] 12 V = 16 V =
Max. current [A] 2.1 1.3
Coil resistance at 20 °C [Ohm] 4.28 12
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
Signal/pressure curve
350
300
250
200
150
100
50
0 8
0 25 50 75 100
Flow Q [%]
The performance curves are measured with external drain. For internal
drain the tank pressure has to be added to curve.
NG H B d1 d2 t L
16 135 79 1) 32 25 56 114
25 140 85 45 34 72 102
32 145 102 60 45 85 95
40 137 (180.2) 2) 125 75 55 105 106
50 172 (215.2) 2) 140 90 68 122 106
63 187 (230.2) 2) 180 120 90 155 106
8
Port X only usable for remote vent function.
Ordering code
RE E T 1 S 1 0
Prop. Nominal Slip-in Pressure Onboard Pilot oil Poppet Seal Normally Command Electr. Options Design Spool
pressure size mounting stages electronics (pilot int., spring open signal attach- series type
relief valve ISO 7368 drain ext.) ments (not required
with elec. for ordering)
unloading Code Spool type
omit Standard
Code Nominal size with poppet
S07 2)
16 NG16 seals
25 NG25 Code Options
32 NG32 omit Standard
40 1) NG40 Mechanical max.
50 1) NG50 M
adjustment
63 1) NG63
Code Command signal
Code Pressure stages Voltage input
10 up to 105 bar F 0...+10 V with ref.
17 up to 175 bar output +10 V
25 up to 250 bar Current input
R
35 up to 350 bar 4...20 mA
General
Nominal size NG16 NG25 NG32 NG40 NG50 NG63
Interface Slip-in mounting acc. ISO 7368
Mounting position as desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 75
Weight [kg] 2.7 5.2 6.4 9.5 15.2 24.3
Vibration strength [g] 10 sinus 5...2000 Hz acc. to IEC 68-2-6
30 noise 20...2000 Hz acc. to IEC 68-2-36
15 shock acc. to IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports A and X 350, ports B and Y 30
Pressure stages [bar] 105, 175, 250, 350
Nominal flow [l/min] 220 500 950 1400 2300 4000
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical
Duty ratio ED [%] 100
Supply voltage VDC 18...30, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0
Pre-fusing [A] 2.5 medium lag
Potentiometer supply [V] +10 / ±5 % max. 10 mA
Command signal Code F voltage [V] 0...+10, ripple < 0.01 % eff., surge free, Ri = 100 kOhm
Code R current [mA] 4...20, ripple < 0.01 % eff., surge free, Ri = 200 Ohm
< 3.6 mA = enable off, > 3.8 mA = enable on (acc. NAMUR NE43)
Differential input voltage max. [V] 30 for terminal D and E against PE (terminal G)
8
[V] 11 for terminal D and E against 0V (terminal B)
Adjustment ranges Min current [%] 0...50
Max current [%] 50...100
Ramp [s] 0...32.5
Interface RS 232C, parametrizing connection 5-pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection 6 + PE acc. EN 175201-804
Cable specification [mm²] 7 x 1.0 overall braid shield
Cable length max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply
is to be switched off by a suitable switching element with sufficient reliability.
350
300
250
200
150
100
50
0
0 25 50 75 100
Flow Q [%]
8
Minimum pressure curve RE*E*T
The performance curves are measured with external drain. For internal
drain the tank pressure has to be added to curve.
Block diagram
Code F
6 + PE acc. EN 175201-804
0
Command E
0...10 V µC
D
Potentiometer
supply
+10 V C
0
G A B
Supply
PE voltage
18...30 V=
Code R
6 + PE acc. EN 175201-804
8 0
Command E
R: 4...20 mA µC
D
0
G A B
Supply
PE voltage
18...30 V=
ID no. 5004072
PG13.5
RE_E_T UK.INDD CM 16.04.15
NG H B d1 d2 t L
16 179 79 1) 32 25 56 114
25 124 85 45 34 72 102
32 129 102 60 45 85 95
40 139 (182.2) 2) 125 75 55 105 106
50 174 (217.2) 2) 140 90 68 122 106
63 189 (232.2) 2) 180 120 90 155 106
Features
• Pilot operated unloading valve
• Cavity and mounting pattern according to ISO 7368
• 4 pressure stages
• 2 switching types (series US*E)
• 2 adjustment modes
- Hand knob
- Turning knob with key lock
• 6 sizes NG16 to NG63
US*E
Note
Port X only usable for remote vent function
UR*E US*E
8
UR*E
UR E 1 S
Unloading Nominal Slip-in Pressure Adjust- Pilot oil Poppet Seal Design
valve size mounting stages ment (pilot internal, spring series
ISO 7368 drain external) (not required
for ordering)
US*E
US E 1 S W
Unloading Nominal Slip-in Pressure Adjust- Pilot oil Poppet Seal Switching Solenoid Without Options Design
valve with size mounting stages ment (pilot int., spring type plug series
elec. un- ISO 7368 drain ext.) (not required
1) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
UR*E
General
Nominal size NG16 NG25 NG32 NG40 NG50 NG63
Interface Slip-in mounting acc. ISO 7368
Mounting position as desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.2 3.5 4.9 8.0 13.7 22.8
Hydraulic
Max. operating pressure [bar] Ports A and X up to 350, Ports B and Y 30
Pressure stages [bar] 75, 175, 250, 350
Pressure differential, nominal [%] 15
Nominal flow [l/min] 220 500 950 1400 2300 4000
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
US*E
General
Nominal size NG16 NG25 NG32 NG40 NG50 NG63
Interface Slip-in mounting acc. ISO 7368
Mounting position as desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value
Weight
[years] 75
[kg] 2.7 5.2 6.4 9.5 15.2 24.3
8
Hydraulic
Max. operating pressure [bar] Ports A and X 350, ports B and Y 30
Pressure stages [bar] 75, 175, 250, 350
Pressure differential, nominal [%] 15
Nominal flow [l/min] 220 500 950 1400 2300 4000
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Dimensions UR*E
NG16 to NG32 NG40 to NG63 1)
NG H B L1 L2 L3 L4 L5 d1 d2 t
16 40 65 2) 32.5 — 114 152 117 32 25 56
25 47 85 42.5 — 102 139 106 45 34 71
32 50 102 51 — 95 131 97.5 60 45 85
40 106 125 62.5 66.5 106 144 108 75 55 105
50 141 140 70 74 106 144 108 90 68 121
63 155 180 90 94 106 144 108 120 90 155
Dimensions US*E
NG16 to NG32 NG40 to NG63 1)
L1 L5
L1 L5
B
B
Acorn nut
with lead seal
H
P Acorn nut
with lead seal
P
Adaptor
Cylinder lock H plate1)
X Y Hand knob
25 Cylinder lock
t
Hand knob
Ød2
Ød1 L3
L2 L4 26 L6
X Y
8
t
Ød2
Ød1 L3
L2 L4 26 L6
NG H B L1 L2 L3 L4 L5 L6 d1 d2 t
16 40 65 2) 32 32.5 114 152 127.5 117 32 25 56
25 47 85 46 42.5 102 139 117 106 45 34 71
32 50 102 51 51 95 131 112.5 97.5 60 45 85
40 106 125 66 62.5 106 144 114 108 75 55 105
50 141 140 74 70 106 144 114 108 90 68 121
63 155 180 94 90 106 144 114 108 120 90 155
Pressure relief valve with cover with integrated pressure relief function
2 1 3
X Y
a B
NG16 - NG32
Type
Description NG16 NG25 NG32
Cover incl. pressure valve 1) C016Fxxxxxxxxxx C025Fxxxxxxxxxx C032Fxxxxxxxxxx
Cover orifice M5xØ1.0 M5xØ1.1 M6xØ1.2
Cover orifice M4xØ0.8 M5xØ0.9 M6xØ1.0
Cover orifice M5xØ99 M5xØ99 M6xØ99
Cartridge 2) CP016C07S00X CP025C07S00X CP032C07S00X
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2
Spring 1.6 bar, typ S
Volume reduction 45036578 45036579 45036580
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55
Shown orifice Ø and springs are recommendations.
xxØ00 = plug
xxØ99 = open
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Pressure valve 1) R06Mxxx4x
Adaptor plate 2) without PADA1007/A-B/B-A
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 4) CP016C07* CP025C07* CP032C07* CP040C07* CP050C07* CP063C07*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK443, 4x M5x45
1)
Shown orifice Ø and springs are recommendations. Complete type see pilot valves.
2) Included O-rings and mounting bolts.
xxØ00 = plug
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CP*.
P A B T
3 1 4
a B
NG16 - NG32
Flow A B
Type
Description NG16 NG25 NG32
4/2 DC valve 1) D1VW104K*
Cover incl. pressure valve 2) C016Gxxxxxxxxxx C025Gxxxxxxxxxx C032Gxxxxxxxxxx
Cover orifice M5xØ1.0 M5xØ1.1 M6xØ1.2
Cover orifice M5xØ99 M5xØ99 M6xØ99
Cover orifice M4xØ00 M5xØ00 M6xØ00
Cover orifice M5xØ1.2 M5xØ1.3 M6xØ1.4
Cartridge 3) CP016C07* CP025C07* CP032C07*
Poppet orifice a 1/16NPT x Ø0.8 1/16NPT x Ø0.8 1/16NPT x Ø1.0
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55
Bolt kit 4/2 DC valve BK375, 4x M5x30
Shown orifice Ø and springs are recommendations.
xxØ00 = plug
xxØ99 = open
1) Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete type see ordering code C*G.
3) Complete type see ordering code CP*.
A B
P T
A B
P T P A B T
P A B T P A B T
3 1 2 4 3 2 1 4
X Z1 Z2 Y X Z2 Z1 Y
a B a B
A A
8 NG16 - NG40
Flow A B
NG50 - NG63 Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
4/2 DC valve 1) D1VW104K*
Pressure valve 2) V-ZUDB1ATxZ07x
Adaptor plate NG10-NG06 3) without PADA1007/A-B/B-A
Cover 4) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.5 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 5) CP016C07* CP025C07* CP032C07* CP040C07* CP050C07* CP063C07*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1482
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete types see pilot valves.
xxØ00 = plug
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CP*.
Examples pressure.INDD CM 16.04.15
P A B T
3 1 4
a B
NG16 - NG32
Flow A B
8
Type
Description NG16 NG25 NG32
4/2 DC valve 1) D1VW105K*
Cover incl. pressure valve 2) C016Gxxxxxxxxxxxx C025Gxxxxxxxxxxxx C032Gxxxxxxxxxxxx
Cover orifice M5xØ1.0 M5xØ1.1 M6xØ1.4
Cover orifice M5xØ99 M5xØ99 M6xØ99
Cover orifice M4xØ00 M5xØ00 M6xØ00
Cover orifice M5xØ1.2 M5xØ1.3 M6xØ1.4
Cartridge 3) CP016C07* CP025C07* CP032C07*
Poppet orifice a 1/16NPT x Ø0.8 1/16NPT x Ø0.8 1/16NPT x Ø1.0
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55
Bolt kit pilot BK375, 4x M5x30
Shown orifice Ø and springs are recommendations.
xxØ00 = plug
xxØ99 = open
1) Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete type see ordering code C*G.
3) Complete type see ordering code CP*.
A B
P T
A B
P T P A B T
A X
P A B T P A B T B Y
3 1 2 4 3 2 1 4
X Z1 Z2 Y X Z2 Z1 Y
a B a B
8 A A
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
4/2 DC valve 1) D1VW105K*
Pressure valve 2) V-ZUDB1ATxZ07x
Adaptor plate 3) without PADA1007/A-B/B-A
Cover 4) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 5) CP016C07* CP025C07* CP032C07* CP040C07* CP050C07* CP063C07*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1482
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete types see pilot valves.
xxØ00 = plug
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CP*.
Examples pressure.INDD CM 16.04.15
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Prop. pressure valve 1) RE06MxW2V1KW
Adaptor plate 2) without PADA1007/A-B/B-A
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.4 M5xØ1.4 M5xØ1.4 M5xØ1.4 M6xØ1.4
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.5 M6xØ1.5 M6xØ1.5 M6xØ1.5 M8xØ1.5
Cartridge 4) CP016C07* CP025C07* CP032C07* CP040S07* CP050S07* CP063S07*
Poppet orifice a 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3
Spring 0.5 bar, type S
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK375, 4x M5x30
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Pressure Valves“, series RE06M*W.
2) Inclusive O-Ringe and mounting bolts.
xxØ00 = plug
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CP*.
Type
Description NG16 NG25 NG32
Prop. pressure valve 1) RE06MxW2V1xW
Cover incl. pressure valve 2) C016Gxxxxxxxxxxxx C025Gxxxxxxxxxxxx C032Gxxxxxxxxxxxx
Cover orifice M5xØ1.4 M5xØ1.4 M6xØ1.4
Cover orifice M5xØ99 M5xØ99 M6xØ99
Cover orifice M4xØ99 M5xØ99 M6xØ99
Cover orifice M5xØ1.5 M5xØ1.5 M6xØ1.5
Cartridge 3) CP016C07* CP025C07* CP032C07*
Poppet orifice a 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55
Bolt kit pilot BK375, 4x M5x30
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Prop. pressure valve 1) RE06MxW2V1KW
Max. pressure valve 2) V-ZUDB1PTxZ07x
Adaptor plate NG10-NG06 3) without PADA1007/A-B/B-A
Cover 4) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.4 M5xØ1.4 M5xØ1.4 M6xØ1.4
Cover orifice M5xØ99 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.5 M6xØ1.5 M6xØ1.5 M8xØ1.5
Cartridge 5) CP016C07* CP025C07* CP032C07* CP040S07* CP050S07* CP063S07*
Poppet orifice a 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3 1/16NPT x Ø1.3
Spring 0.5 bar, type N
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1482
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Pressure Valves“, series RE06M*W.
2) Complete types see pilot valves.
xxØ00 = plug
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CP*.
Examples pressure.INDD CM 16.04.15
Unloading valve
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Unloading valve 1) – UR06Mxxx4x
Adaptor plate NG10-NG06 2) – – – – PADA1007/A-B/B-A
Cover 3) on request C040CA* C050CA* C063CA*
Cover orifice M5xØ1.4 M6xØ1.4
Cover orifice M5xØ00 M6xØ00
Cartridge 4) CP16C07* CP25C07* CP032C07* CP040S07* CP050S07* CP063S07*
Poppet orifice a 1/16NPT x Ø1.2
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK443, 4x M5x45
1)
Shown orifice Ø and springs are recommendations. Complete types see pilot valves.
2) Included O-rings and mounting bolts.
xxØ00 = plug
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CP*.
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
4/2 DC valve 1) – D1VW076K*
Pressure valve 2) US06Mxxx4x
Adaptor plate NG10-NG06 3) – – – – PADA1007/A-B/B-A
Cover 4) on request C040CA* C050CA* C063CA*
Cover orifice M5xØ1.4 M6xØ1.4
Cover orifice M5xØ00 M6xØ00
Cartridge 5) CP016C07* CP025C07* CP032C07* CP040S07* CP050S07* CP063S07*
Poppet orifice a 1/16NPT x Ø1.2
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK401, 4x M5x75
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete types see pilot valves.
xxØ00 = plug
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CP*.
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
4/2 DC valve 1) D1VW078K*
Pressure valve 2) US06Mxxx4x
Adaptor plate NG10-NG06 3) – – – – PADA1007/A-B/B-A
Cover 4) on request C040CA* C050CA* C063CA*
Cover orifice M5xØ1.4 M6xØ1.4
Cover orifice M5xØ00 M6xØ00
Cartridge 5) CP016C07* CP025C07* CP032C07* CP040S07* CP050S07* CP063S07*
Poppet orifice a 1/16NPT x Ø1.2
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK401, 4x M5x75
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete types see pilot valves.
xxØ00 = plug
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CP*.
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Press. sequ. valve 1) S06Mxxx4x
Adaptor plate NG10-NG06 2) without PADA1007/A-B/B-A
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ0.9 M6xØ1.1 M6xØ1.2 M6xØ1.3 M8xØ1.4 M8xØ1.5
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 4) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01*
Poppet orifice a 1/16NPT x Ø00
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK443, 4x M5x45
1)
Shown orifice Ø and springs are recommendations. Complete types see pilot valves.
2) Included O-rings and mounting bolts.
xxØ00 = closed bottom NG16 - NG50, plug NG63
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CE*.
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Preload valve 1) DSBA100xP07x
Adaptor plate NG10-NG06 2) without PADA1007/A-B/B-A
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 4) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot BK443, 4x M5x45
1)
Shown orifice Ø and springs are recommendations. Complete type see pilot valves.
2) Included O-rings and mounting bolts.
xxØ00 = closed bottom NG16 - NG50, plug NG63
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CE*.
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Pressure valve 1) R06Mxxx4x
Preload valve 1) DSBA100xZ07x
Adaptor plate NG10-NG06 2) without PADA1007/A-B/B-A
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 4) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1482
1)
Shown orifice Ø and springs are recommendations. Complete type see examples pilot valve.
2) Included O-rings and mounting bolts.
xxØ00 = closed bottom NG16 - NG50, plug NG63
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CE*.
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Prop. press. valve 1) RE06MxW2V1KW*
Preload valve 2) DSBA100xZ07x
Adaptor plate NG10-NG06 3) without PADA1007/A-B/B-A
Cover 4) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 5) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1482
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Pressure Valves“, series RE06M*W.
2) Complete type see pilot valves.
xxØ00 = closed bottom NG16 - NG50, plug NG63
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CE*.
Examples pressure.INDD CM 16.04.15
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
4/2 DC valve 1) D1VW076K*
Press. valve 2) ZUDB1ATxZ07x
Preload valve 2) DSBA100xZ07x
Adaptor plate NG10-NG06 3) without PADA1007/A-B/B-A
Cover 4) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 5) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1473
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter “Directional Control Valves“, series D1VW.
2) Complete type see pilot valves.
xxØ00 = closed bottom NG16 - NG50, plug NG63
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CE*.
Examples pressure.INDD CM 16.04.15
8
Adaptor plates see chapter 12
Type
Description NG16 NG25 NG32 NG40 NG50 NG63
Prop. press. valve 1) RE06MxW2V1KW*
Press. valve 2) ZUDB1ATxZ07x
Preload valve 2) DSBA100xZ07x
Adaptor plate NG10-NG06 3) without PADA1007/A-B/B-A
Cover 4) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA*
Cover orifice M5xØ1.1 M5xØ1.3 M5xØ1.4 M5xØ1.5 M6xØ1.6 M6xØ1.7
Cover orifice M5xØ00 M6xØ00
Cover orifice M5xØ99 M6xØ99 M8xØ99
Cover orifice M5xØ1.3 M6xØ1.5 M6xØ1.7 M6xØ1.8 M8xØ2.0 M8xØ2.2
Cartridge 5) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01*
Poppet orifice a 1/16NPT x Ø0.9 1/16NPT x Ø1.1 1/16NPT x Ø1.2 1/16NPT x Ø1.3 1/16NPT x Ø1.4 1/16NPT x Ø1.5
Spring 1.6 bar, type S
Volume reduction 45036578 45036579 45036580 45036581 45036582 45036583
Bolt kit cover BK414, 4x M8x40 BK391, 4x M12x50 BK415, 4x M16x55 BK416, 4x M20x70 BK417, 4x M20x75 BK418, 4x M30x100
Bolt kit pilot TK1473
1) Complete type see chapter “Pressure Valves“, series RE06M*W.
Shown orifice Ø and springs are recommendations.
2) Complete type see pilot valves.
xxØ00 = closed bottom NG16 - NG50, plug NG63
3) Included O-rings and mounting bolts.
xxØ99 = open 4) Complete type see ordering code C*C.
5) Complete type see ordering code CE*.
Examples pressure.INDD CM 16.04.15
Features
• Cavity and mounting pattern according to ISO 7368
• 4 different springs
• 8 sizes NG16 to NG100
X Z1 Z2 Y
Ordering code
C1DB 101 E 0 99 00
Seal Check Cover Slip-in Nominal Design Closing
valve valve size series spring
Code Seal Code Spring
omit NBR L 0.1 bar
V FPM N 0.5 bar
Code
16
Nominal size
NG16
S
T
1.6 bar
2.5 bar 8
25 NG25 U 4.0 bar
32 NG32
40 NG40
50 NG50
63 NG63
80 NG80
100 NG100
Technical data
General
Design 2-way cartridge valve, according to ISO 7368
Nominal size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Actuation hydraulical
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 150
Weight [kg] 1.2 2.5 3.9 7 11.4 21.8 45 74
Hydraulics
Flow direction See symbols
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal pressure [bar] 350
Flow [l/min] 250 450 900 1300 1800 3600 5250 8000
Opening pressure, spring [bar] L = 0.1; N = 0.5; S = 1.6; U = 4.0
C1DB UK.INDD CM 16.04.15
Performance curves
Dimensions
/ØB
NG L B d1 d2 t2
16 36 65 32 25 56
25 45 85 45 34 72
L
32 50 102 60 45 85
40 60 125 75 55 105
X Y
50 70 140 90 68 122
63 85 180 120 90 155
t2
8 Ød2
Ød1
Springs
Ordering number
Spring type
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
L (0.1 bar) 45051368 45051375 45051376 45051382 45051384 45051388 45051395 45051400
N (0.5 bar) 45051369 45051374 45051377 45051381 45051385 45051389 45051396 45051401
S (1.6 bar) 45051370 45051372 45051378 45051380 45051386 45051390 45051397 45051402
U (4.0 bar) 45051371 45051373 45051379 45051383 45051387 45051391 45051398 45051403
Function
When no pressure is applied to the X-port, the flow from
B to A is blocked, because the pressure in B is also ef-
fective on top of the poppet.
Pressurizing the X-port relieves the area on top of the
poppet to the drain port and allows flow from B to A. The
seat design of the SVLB valve series provides leak-free
separation of port A and B in the closed position.
Features
• Pilot operated check valve
• Cavity and mounting pattern acc. to ISO 7368
• Dampening poppet optional
• 5 sizes NG16 to NG50
Ordering code
SVL B 10 6 E
Seal Hydr. Slip-in Design Poppet Pilot Slip-in Valve Closing Design series
operated mounting style type control cartridge size spring (not required
check acc. to ratio valve for ordering)
valve ISO 7368 6:1
Code Seal Code Spring
omit NBR N 0.5 bar
V FPM S 1.6 bar
T 2.5 bar
Code Poppet type U 4.0 bar
4 04
8 1) 08 Code Size
16 NG16
25 NG25
1) With damping nose. 32 NG32
40 NG40
50 NG50
Technical data
General
Nominal size NG16 NG25 NG32 NG40 NG50
Interface Slip-in mounting acc. ISO 7368
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 2.3 3.2 4.6 7.8 12.0
Hydraulics
8 Max. operating pressure
Nominal flow
[bar] 350
[l/min] 250 450 900 1300 1800
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [C°] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Size 16 25 32 40 50
H 84 88 93 103 138
b1 79* 85 102 125 140
d1H7 32 45 60 75 90
d2H7 25 34 45 55 68
t2+0.1 56 72 85 105 122
Bges. 99 94 103 125 140
* Width 65 mm.
a B
Type
Description
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Cover 1) C016AA* C025AA* C032AA* C040AA* C050AA* C063AA* C080AA* C100AA*
Cover orifice 1 1/16xØ0.8 1/16xØ1.0 1/16xØ1.2 1/8xØ1.5 1/8xØ1.8 1/8xØ2.0 1/8xØ2.2 1/8xØ2.5
Cartridge 2) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01* CE080C01* CE100C01*
Poppet orifice a 1/16xØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130
1)
Shown orifice Ø and springs are recommendations. Complete type see ordering code C*A.
2) Complete type see ordering code CE*.
xxØ00 = closed bottom NG16 - NG50, plug NG63 - NG100
xxØ99 = open
a B
Type
Description
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Cover 1) C016B** C025B** C032B** C040B** C050B** C063B** C080B** C100B**
Cover orifice 1 M6xØ0.8 M6xØ1.0 1/16xØ1.2 1/16xØ1.5 1/16xØ1.8 1/8xØ2.0 1/8xØ2.2 1/8xØ2.5
Cartridge 2) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01* CE080C01* CE100C01*
Poppet orifice a 1/16xØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130
1)
Shown orifice Ø and springs are recommendations. Complete type see ordering code C*B.
2) Complete type see ordering code CE*.
xxØ00 = closed bottom NG16 - NG50, plug NG63 - NG100
xxØ99 = open
Examples-2way.INDD CM 16.04.15
a B
Type
Description
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Cover 1) C016AA* C025AA* C032AA* C040AA* C050AA* C063AA* C080AA* C100AA*
Cover orifice 1 1/16xØ0.8 1/16xØ1.0 1/16xØ1.2 1/8xØ1.5 1/8xØ1.8 1/8xØ2.0 1/8xØ2.2 1/8xØ2.5
Cartridge 2) CE016C08* CE025C08* CE032C08* CE040C08* CE050C08* CE063C08* CE080C08* CE100C08*
Poppet orifice a 1/16xØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130
1)
Shown orifice Ø and springs are recommendations. Complete type see ordering code C*A.
2) Complete type see ordering code CE*.
xxØ00 = plug
xxØ99 = open
a B
Type
Description
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Cover 1) C016B* C025B* C032B* C040B* C050B* C063B* C080B* C100B*
Cover orifice 1 M6xØ0.8 M6xØ1.0 1/16xØ1.2 1/16xØ1.5 1/16xØ1.8 1/8xØ2.0 1/8xØ2.2 1/8xØ2.5
Cartridge 2) CE016C08* CE025C08* CE032C08* CE040C08* CE050C08* CE063C08* CE080C08* CE100C08*
Poppet orifice a 1/16xØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130
1)
Shown orifice Ø and springs are recommendations. Complete type see ordering code C*B.
2) Complete type see ordering code CE*.
xxØ00 = plug
xxØ99 = open
Examples-2way.INDD CM 16.04.15
P A B T
P A B T P A B T P A B T
3 1 2 4 3 2 1 4 3 2 1 4
X Z1 Z2 Y X Z2 Z1 Y X Z2 Z1 Y
a B a B a B
A A A
NG16 - 40 with NG50 - 63 with NG50 - 100 with
pilot NG06 pilot NG06 pilot NG10
Type
Description Pilot NG06 Pilot NG10
NG16 NG25 NG32 NG40 NG50 NG63 NG50 NG63 NG80 NG100
4/2-DC valve 1) D1VW20B* D3W20H*
Adaptor plate 2) without PADA1007/A-B/B-A without
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA* C050CA* C063CA* C080CA* C100CA*
Cover orifice 1 M5xØ0.8 M5xØ1.0 M5xØ1.2 M5xØ1.5 M6xØ1.8 M6xØ2.0 M6xØ1.8 M6xØ2.0 1/16xØ2.2 1/16xØ2.5
Cover orifice 2 M5xØ00 M6xØ00 1/16xØ00
Cover orifice 3 M5xØ1.0 M6xØ1.2 M6xØ1.5 M6xØ1.8 M8xØ2.0 M8xØ2.2 M8xØ2.0 M8xØ2.2 M10x1xØ2.5 M10x1xØ3.0
Cover orifice 4 M5xØ99 M6xØ99 M8xØ99C M10x1xØ99
Cartridge 4) CE016C04* CE025C04* CE032C04* CE040C04* CE050C04* CE063C04* CE050C04* CE063C04* CE080C04* CE100C04*
Poppet orifice a 1/16NPTxØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509 BK419 BK420
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130 8x M24x120 8x M30x140
Bolt kit pilot BK375 4x M5x30 BK385 4x M6x40
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter "Directional Control Valves", series D1VW, D3W.
2) NG10-NG06 inclusive O-rings and mounting bolts.
xxØ00 = closed bottom NG16 - NG50, plug NG63 - NG100
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CE*.
Examples-2way.INDD CM 16.04.15
2-way seat valve with pilot and dampening poppet, normally closed, flow A Û B
Type
Description Pilot NG06 Pilot NG10
NG16 NG25 NG32 NG40 NG50 NG63 NG50 NG63 NG80 NG100
4/2-DC valve 1) D1VW20B* D3W20H*
Adaptor plate 2) without PADA1007/A-B/B-A without
Cover 3) C016CA* C025CA* C032CA* C040CA* C050CA* C063CA* C050CA* C063CA* C080CA* C100CA*
Cover orifice 1 M5xØ0.8 M5xØ1.0 M5xØ1.2 M5xØ1.5 M6xØ1.8 M6xØ2.0 M6xØ1.8 M6xØ2.0 1/16xØ2.2 1/16xØ2.5
Cover orifice 2 M5xØ00 M6xØ00 1/16xØ00
Cover orifice 3 M5xØ1.0 M6xØ1.2 M6xØ1.5 M6xØ1.8 M8xØ2.0 M8xØ2.2 M8xØ2.0 M8xØ2.2 M10x1xØ2.5M10x1xØ3.0
Cover orifice 4 M5xØ99 M6xØ99 M8xØ99C M10x1xØ99
Cartridge 4) CE016C08* CE025C08* CE032C08* CE040C08* CE050C08* CE063C08* CE050C08* CE063C08* CE080C08* CE100C08*
Poppet orifice a 1/16NPTxØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509 BK419 BK420
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130 8x M24x120 8x M30x140
Bolt kit pilot BK375 4x M5x30 BK385 4x M6x40
1)
Shown orifice Ø and springs are recommendations. Complete type see chapter "Directional Control Valves", series D1VW, D3W.
2) NG10-NG06 inclusive O-rings and mounting bolts.
xxØ00 = plug
3) Complete type see ordering code C*C.
xxØ99 = open 4) Complete type see ordering code CE*.
Examples-2way.INDD CM 16.04.15
a B
Type
Description
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Cover 1) C016AA* C025AA* C032AA* C040AA* C050AA* C063AA* C080AA* C100AA*
Cover orifice 1 M5xØ99 M6xØ99 1/16xØ99
Cartridge 2) CE016C01* CE025C01* CE032C01* CE040C01* CE050C01* CE063C01* CE080C01* CE100C01*
Poppet orifice a 1/16NPTxØ00
Spring 1.6 bar, type S
BK414 BK391 BK415 BK416 BK417 BK418 BK419 BK509
Bolt kit cover
4x M8x40 4x M12x50 4x M16x55 4x M20x70 4x M20x75 4x M30x100 8x M24x120 8x M30x130
1)
Shown orifice Ø and springs are recommendations. Complete type see ordering code C*A.
2) Complete type see ordering code CE*.
xxØ00 = closed bottom NG16 - NG50, plug NG63 - NG100
xxØ99 = open
Examples-2way.INDD CM 16.04.15
Features C10C3E
• Cover to mount a directional control valve (on the side)
for cover 3 X
• Cavity and mounting pattern acc. to ISO 7368
• Monitored closed position
Code S
• Inductive switch CE conform with seal
• Optional with poppet sealing between pilot flow C and
port B.
• 8 sizes, NG16 up to NG100
C10C1E
Ordering code
C 10 C E
1 2 3 4
Poppet shape Cover Nominal Nominal opening Seal Design
60/40 size pressure spring series
(not required
2/2-way Ind. monitoring Slip-in Poppet Orifice for ordering)
valve hydraulic
operation
cartridge
ISO 7368
seal
8
Code Cover Nominal opening Code Seal
Code
1 without pilot valve interface pressure spring N NBR
3 1) with pilot valve interface L 0.1 bar V FPM
N 0.5 bar
Code Nominal size S 1.6 bar Code Orifice
016 NG16 T 2.5 bar no orifice
ohne
025 NG25 U 4.0 bar (2-4 cover 1)
032 NG32 00 Plug
040 NG40 open, without
99
orifice
050 NG50
063 NG63
Cover 3
080 NG80
100 NG100 P
A
S 2) with
T
G
G B
1 3
T
Please order female connector M12x1 separately 1 2 4
B B
1) The DC valve is not included in the delivery.
We recommend the following pilot valves: D1VW020BN*W or D1VW020HN*W,
A A
depending on the required functionality and plug location.
2) Only with spring S, T and U.
Technical data
General
Design 2-way slip-in cartridge valves ISO 7368
Size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Operation hydraulic
Ambient temperature [C°] -20...+60
MTTFD value [years] 150
Weight [kg] 1.5 2.7 4.3 7.4 12 23 53 89
Hydraulic
Max. operating pressure [bar] 350
Nominal flow ∆p 5 bar [l/min] 230 400 800 1250 1625 3400 5000 7500
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [C°] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Control volume at max. stroke [cm³] 2.03 6.45 12.21 20.32 39.40 94.56 950 1300
Control surface (surface C = 100 %) A/B [%] approx. 60 / 40 related on surface C
Opening pressure
flow direction A—>B [bar] Spring: L = 0.2; N = 0.9; S = 2.7; T = 4.0; U = 6.6
flow direction B—>A [bar] Spring: L = 0.3; N = 1.3; S = 4.0; T = 6.3; U = 10.0
Electrical (Inductive switch) See position control
Cover Orifice NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
C10C1E No.: 1 1/16 NPT 1/16 NPT 1/16 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
C10C3E No.: 1, 2, 3, 4 M5 M6 M6 M6 M8 M8 1/8 NPT 1/8 NPT
Inlet orifice Ø 0.8 Ø 1.2 Ø 1.5 Ø 2.0 Ø 2.5 Ø 3.0 Ø 3.0 Ø 3.0
Depending on function, plugs must be used (code00).
Dimensions C10C1E
NG16 to NG63 1) NG80 to NG100 1)
29.5
H
h1
h2
X
t2
Ød2
Ød1 8
Cavity and mounting pattern acc. to ISO 7368
NG H h h2 b1 d1 d2 t +0.1
16 107 36 28 65 32 25 56
25 116 45 32.5 85 45 34 72
32 122 50 32 102 60 45 85 The space necessary to remove the M12x1 female connector is at
40 131 60 40 125 75 55 105 least 22 mm.
50 141 70 45 140 90 68 122
63 156 85 55 180 120 90 155
80 195 105 80 250 145 110 205
100 210 120 89 300 180 135 245
Dimensions C10C3E
NG16 to NG50 1) NG63 1)
Pilot valve interface NG06. Pilot valve interface NG10.
4
M12-DIN 580
b2
No defined position for
female connector. 3.5 b1 3.5
29.5
3.5 b1 3.5
29.5
No defined position
for female connector.
b2
b2
H
H
A
P
h1
h3
B
h2
h1
h2
h3
Z2 Z1
X Y Z2 Z1
t2
8
t2
Ød2
Ød1
Ød2
Ød1
Cavity and mounting pattern acc. to ISO 7368 Cavity and mounting pattern acc. to ISO 7368
NG H h1 h2 h3 b1 b2 d1 d2 t2
16 156 85 76 72 65 15.5 31 25 56
25 156 85 70 72 85 15.5 45 34 72
32 156 85 56 72 102 15.5 60 45 85
40 156 85 50 72 125 15.5 75 55 105
50 156 85 60 72 140 15.5 90 68 122 The space necessary to remove the M12x1
63 181 110 75 91 180 21.5 120 90 155 female connector is at least 22 mm.
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
1) Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Dimensions C10C3E
NG80 to NG100 1)
Pilot valve interface NG10.
b3
H
T
A
h1
P
h3
h2
B
T
Y
Z2 Z1
8
t2
Ød2
Ød1
NG H h1 h2 h3 b1 b2 b3 d1 d2 t2
80 212.5 120 94 91 250 119 21.5 145 110 205
100 212.5 120 85 91 300 144 21.5 180 135 245
Seal and bolt kits
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
1) Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG16 to NG63
Supply voltage [VDC] 24
Tolernace supply voltage [%] ±20
Ripple supply voltage [%] ≤10
Polarity protection [V] 300
Current consumption without load [mA] ≤20
Switching hysteresis [mm] <0.06
Max. output current per channel, ohmic [mA] 250
Ambient temperature [°C] -20 … +60
Protection IP65 acc. EN 60529
CE conform 1) EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6 1) / ENV 50140 / ENV 50204
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
1
US
DC st
1 + US 19.2...28.8 V
2 1 2 Out B: normally open
DC
OSZ.
AC
4
Out
DC
3 0V 2
3 4 4 Out A: normally closed
Out neg.
3
GND
Please order plug M12x1 separately (see accessories directional control valves, plug M12x1; order no.: 5004109)
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG80 to NG100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C]0...+50
Supply voltage US / ripple [V]10...30 / 10 %
Current consumption without load [mA] ≤ 10
Max. output current per channel, ohmic [mA] 200
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V]≤2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1
Wiring min. [mm²] 3 x 0.14 braid shield recommended
Wiring length max. [m] 50 recommended
1 + US 10...30 V
2 Out A: not connected
3 0V
4 Out A: normally closed
8
Definition
Start position monitored:
The switching point of the inductive switch is within the
overlap of the poppet.
After the signal of the inductive switch has changed, the
poppet leaves the safety overlapping position.
Features
• Active pilot operated 2/2-way cartridge valves
• Cavity and mounting pattern according to ISO 7368
(except for size NG125)
• Flow direction B to A and A to B
• 8 sizes NG25 up to NG125
• Position monitoring optional
• Stroke limiter optional
TDW040 optional
position control
8 Code 2
Pilot with
cover plate
A B
A B
P
P
B
B A X Y
A
X Y Orifice plate
Sinus poppet
TDW E W 9 C 2 N J W
2/2-way Slip-in Sinus Flow Seal Pilot direct Omit for valves P A B
cartridge cartridge poppet direction NBR operated without Recommended
valve DC pilot B→A DC valve orifice
A→B
Connector as per
EN175 301-803
Nominal Design Nominal Pilot oil Position Solenoid Options
size flow (supply external, control voltage DC valve
100 % drain external) DC valve
24 V =
Code Options
Code Pilot
0 Standard
with DC valve,
1 without manual
normally open T
override
with cover plate
2 X = closing
Y = opening
with DC valve,
9
normally closed
General
Design 2-way slip-in cartridge valve according to ISO 7368 (except for size NG125)
Nominal size DIN NG25 NG32 NG40 NG50 NG63 NG80 NG100 NG125
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 8 10 12 23 49 102 154 193
Hydraulic
Max. operating pressure [bar] Ports A, B, X up to 350, port Y: max. 210 (350 bar with cover plate)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -25...+70
Viscosity permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 5 bar [l/min] 420 850 1500 1900 3600 4500 8000 11500
Recommended max. flow [l/min] 800 2000 3000 4500 8000 13000 20000 29000
Flow direction B to A / A to B
Pilot pressure [bar] must be as high as system pressure
Overlap (for poppet code 8) [mm] 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code J
Supply voltage [V] 24 V =
Tolerance supply voltage [%] ±10
Current consumption hold [A] 1.29
Current consumption in rush [A] 1.29
Power consumption hold 31 W
Power consumption in rush 31 W
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W).
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
8 With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG25 to NG63
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] 0...+60
Supply voltage US / ripple [V] 18...42 / 10 %
Current consumption without load [mA] ≤ 30
Max. output current per channel, ohmic [mA] 400
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V] ≤ 1.1
Max. output drop at 0.4 A [V] ≤ 1.6
EMC EN50081-1 / EN50082-2
Max. tolerance ambient field strength [A/m] <1200
Min. distance to next AC solenoid [m] >0.1
Interface M12x1
Wiring min. [mm²] 5 x 0.25 braid shield recommended
Wiring length max. [m] 50 recommended
1 + US 18...42 V
2 Out B: normally open
3 0V
4 Out A: normally closed
5 Earth ground
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG80 to NG125
Protection class
Ambient temperature [°C]
IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
0...+60
8
Supply voltage US / ripple [V]10...30 / 10 %
Current consumption without load [mA] ≤ 10
Max. output current per channel, ohmic [mA] 200
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V]≤2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1
Wiring min. [mm²] 3 x 0.14 braid shield recommended
Wiring length max. [m] 50 recommended
1 + US 10...30 V
2 Out A: not connected
3 0V
4 Out A: normally closed
Control surfaces
The 1:1 standard poppet (Code 1) is pressure balanced. The overlapped poppet (Code
B 8) shows smaller areas AA respectively AB.
E.g. for NG100
A
ANom = 7854 mm2 = 600 %
AB = AA ASt = 1307 mm2 = 100 %
AA=AB = 157 mm2 = 12 %
Dimensions
NG25
NG Bolt kit
NBR FPM
25 BK504 4x M12x100 ISO 4762-12.9 108 Nm SK-TDW025EN30 SK-TDW025EV30
NG32
NG40
NG Bolt kit
NBR FPM
32 BK529 4 x M16x100 ISO 4762-12.9 264 Nm SK-TDW032EN30 SK-TDW032EV30
40 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TDW040EN30 SK-TDW040EV30
NG50
NG Bolt kit
NBR FPM
50 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TDW050EN30 SK-TDW050EV30
NG63
NG Bolt kit
NBR FPM
63 BK518 4 x M30x160 ISO 4762-12.9 1775 Nm SK-TDW063EN30 SK-TDW063EV30
TDW UK.indd CM 16.04.15
NG80
NG Bolt kit
NBR FPM
80 BK530 8x M24x160 ISO 4762-12.9 890 Nm SK-TDW080EN30 SK-TDW080EV30
NG100
NG Bolt kit
NBR FPM
100 BK531 8x M30x150 ISO 4762-12.9 1775 Nm SK-TDW100EN30 SK-TDW100EV30
NG125
NG Bolt kit
NBR FPM
125 BK537 8x M36x180 ISO 4762-12.9 3100 Nm SK-TDW125EN30 SK-TDW125EV30
Code: ISO 7368-B*-*-2-A/B Code: ISO 7368-B*-*-2-A (except for size NG125)
NG25 to NG63 NG80 to NG125
Location pin t10 Thread depth t6 Location pin t10 Thread depth t6
m4
35°
45
°
d7
d6
d7
m3
22,5°
d5
X Y X Y
m1
b1
b1
d5
m1
d6
m1
m2 m2
b1
d1
15° Required surface finish:
1 2
t7
1 = √ Rmax16, 2 = √ Rmax8
t5
2
t4
t1
t2
d2 15°
d4
1
8
t8
t3
8
Ordering code
TDA E W 0 2 W
2-way Nominal Slip-in valve Design Poppet Nominal Flow Piloting Seal Solenoid Plug socket Design
proportional size DIN ISO shape flow direction voltage without series
throttle valve 7368 plug (not required
for ordering)
General
Design 2-way proportional throttle valves, slip-in cartridge according to ISO 7368
Nominal size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 3.1 4.3 5.8 9.2 15 33 63 87
Extracting tool see accessories
Hydraulics
Max. operating pressure [bar] Ports A, B and X up to 350, port Y: max. 10
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 10 bar [l/min] 220 500 950 1400 2300 4000 6000 9500
Flow direction see ordering code
Pilot pressure, min. [bar] > 25 % of system pressure
Min. operating pressure [bar] Port A → B approx. 10; Port B → A approx. 15
Pilot oil supply Depending on flow direction A or B using X or external X
drain External using port Y max. 10 bar
Pilot oil at p = 100 bar [l/min] Port X → Y <1.5
Opening point At 30 % of nominal current
Manufacturing tolerance [%] ±5 of Qnom
Static/dynamic
Response time at px=50 bar [ms] 20 25 30 35 45 55 65 80
Hysteresis [%] < 3
Repeatabiltity [%] < 1
Electrical (proportional solenoid)
Duty ratio 100 % ED
Protection class
Solenoid Code
IP65 according to EN 60529 (with correctly mounted plug-in connector)
L X
8
at size 16-50 63-100 16-50 63-100
Solenoid voltage [V] 6 16
Nominal current (100 % ED) [A] 2.6 1.05
Nominal resistance [Ohm] 2.2 2.5 11.3 14
Power amplifier, recommended PCD 00A-400
Solenoid connection Connector as per EN 175301-803
The pilot pressure in X-line must be at least 25 % (NG16-40) or 45 % (NG50-100) of the pressure in the draining-off
line of the cartridge to make sure that the main poppet closes safely without malfunction.
2000
NG50
1500
1000 NG40
500
NG32
0
0 10 20 30 40 50 60 70 80 90 100
Current A [%]
8000
NG100
6000
8 4000
NG80
2000
NG63
0
0 10 20 30 40 50 60 70 80 90 100
Current A [%]
( QQactual )
2
Dpactual = • Dpnominal
nominal
Poppet stroke / time curve
Size 16 25 32 40 50 63 80 100
H 168 177 182 192 202 304 324 339
b1 65 85 102 125 140 180 Ø250 Ø300
d1H7 32 45 60 75 90 120 145 180
d2H7 25 34 45 55 68 90 110 135
t2+0.1 56 72 85 105 122 155 205 245
Characteristic curve
Ordering code
TEA E W 0 9 2 W
2-way Prop. Nominal Cartridge Design Spool Flow Flow Pilot oil Seals Prop. Plug Solenoid Design
throttle size valve form code direction guide solenoid socket voltage series
valve with ISO 7368 voltage without (not required
shut-off plug for ordering)
function
Code Nominal size Code Solenoid
032 NG32 J 24 V= / 1.25 A
040 NG40 U 1) 98 V= / 0.31 A
050 NG50 G 1) 205 V= / 0.15 A
063 NG63
080 NG80 Proportional
Code
solenoid voltage
100 NG100
L 6 VDC
Code Flow direction X 16 VDC
A A to B
Code Seal
B B to A
N NBR
V FPM
1) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
Technical data
General
Design 2-way Proportional throttle valve, slip-in cartridge according to ISO 7368
Nominal size NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value
Weight
[years] 75
[kg] 9 13 22 38 62 85 8
Extracting tools See accessories
Hydraulics
Max. operating pressure [bar] Ports A, B and X up to 350, port Y max. 10
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow ∆p = 10 bar [l/min] 950 1400 2300 4000 6000 9500
Pilot pressure, min. [bar] > 25 % of system pressure
Pilot oil supply Depending on flow direction A or B using X or external X
Pilot oil at p = 100 bar [l/min] Port X → Y <1.5
Opening point At 30 % of nominal current
Manufacturing tolerance [%] ±5 of Qnom
Static/dynamic
Response time at px = 50 bar [ms] 30 35 45 55 65 80
Hysteresis [%] < 3
Repeatability [%] < 1
Electrical (proportional solenoid)
Duty ratio 100 % ED
Protection class IP65 according to EN 60529 (with correctly mounted plug-in connector)
Solenoid Code L X
at size 16-50 63-100 16-50 63-100
Solenoid voltage [V] 6 16
Nominal current (100 % ED) [A] 2.6 1.05
Nominal resistance [Ohm] 2.2 2.5 11.3 14
Power amplifier, recommended PCD 00A-400, Connector as per EN 175301-803
Solenoid connection pilot valve 4/2 flow control valve
Type D1VW Type D3DW
TEA UK.INDD CM 16.04.15
Size 32 40 50 63 80 100
H 250 260 270 312 337 352
b1 102 125 140 180 Ø 250 Ø 300
d1H7 60 75 90 120 145 180
d2H7 45 55 68 90 110 135
t2+0.1 85 105 122 155 205 245
B2total 106 118 125 158 193 218
B3total 205 216 224 255 290 315
Function
The 2-way high-response valves TDP have a 2-stage
design consisting of a DFplus pilot valve and a main stage
with poppet and LVDT.
With the DFplus pilot valve the TDP achieves extremely TDP032
fast response times: from 10.5 ms (NG25) up to 46 ms
(NG125) with an accuracy of <0.1 % of the nominal flow. Features
The pilot valve actively controls the poppet - independent
of the pressure conditions in the main ports. • Active pilot operated 2-way high-response valve
It is basically required that the pilot pressure is at the • Cavity and mounting pattern according to ISO 7368
level of the system pressure. At low system pressure the (except for size NG125)
pilot pressure should be min. 140 bar, when high valve • Fast step response
dynamics are desired. • Flow direction B to A and A to B
The integrated electronics in the pilot of the TDP has • Completely mounted and adapted unit with integrated
two control loops for the main poppet and the pilot spool. electronics
• 8 sizes NG25 up to NG125
TDP040
Function symbol
SP
BTA
XX
X Y
Ordering code
TDP E 9 C 2 0
2-way high- Nominal Slip-in Performance Flow Nominal Flow Pilot Seal Command Standard Design
response size cartridge charac- flow direction oil signal electronics series
valve teristic B→A (supply ex- (not required
A → B ternal, drain for ordering)
external)
Code Performance
VCD® dynamics especially for Code Flow characteristic
D
closed loop applications 7 progressive
VCD® dynamics especially for 9 linear
H
controlled applications
1) HFC fluids suitable
The DFplus pilot valve is also available with EtherCAT Please order connector separately
interface, see chapter 3, D*FP and D*1FP with EtherCAT. Angle female connector must be used for NG25 to NG50.
8 Dp = 5 bar
Linear (code 9)
Progressive (code 7)
(for TDL replacement)
Opening point factory set to 3 % Flow at different ∆p Qactual = Qnominal • ∆ pactual / ∆ pnominal
General
Design Proportional throttle valve, slip-in cartridge according to ISO 7368 (except for size NG125)
Nominal size DIN NG25 NG32 NG40 NG50 NG63 NG80 NG100 NG125
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 75
Weight [kg] 11 13 15 26 52 105 157 193
Vibration resistance [g] 10 sinus 5...2000 Hz acc. IEC 68-2-6
30 random noise 20...2000 Hz acc. IEC 68-2-36
15 shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports A, B, X and SP up to 350, XX observe accumulator pressure rating;
port Y: max. 35
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity recommended [cSt] / [mm²/s] 30 ... 80
permitted [cSt] / [mm²/s] 20 ... 400
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 5 bar (linear) [l/min] 420 850 1500 1900 3600 4500 8000 11500
Recommended max. flow (linear) [l/min] 800 2000 3000 4500 8000 13000 20000 29000
Nominal flow at ∆p = 5 bar (progressive) [l/min] 380 750 1300 1700 3200 3900 6800 9200
Recommended max. flow (progressive) [l/min] 700 1750 1600 4000 7000 11250 17000 23000
Flow direction B to A / A to B
Pilot pressure [bar] must be as high as system pressure
Pilot oil supply external via X
drain external via Y
Leakage in pilot valve at 100 bar [ml/min] <400
Pilot valve size NG06 NG10
Max. pilot flow at 140 bar pilot pr. [l/min] 23 30 40 40 70 80 100 100
Static/dynamic
(for optimal dynamics see installation recommendation)
Step response at pilot press. >140 bar [ms] 10.5 12 14 20 17 23 28 46
Frequency response at pilot press. >140 bar
Amplitude -3 dB; 10 % ±5 % [Hz] 95 80 74 66 52 46 41 23
Hysteresis
Phase -90°; 10 % +5 % [Hz] 85
[%] < 0.1
63 59 52 56 51 47 45
8
Sensitivity [%] < 0.05
Temperature drift [%/K] < 0.025
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage / ripple [V] DC 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 A medium lag
Input signal Voltage [V] 0...+10, ripple < 0,01 % eff., surge free
Impedance [kOhm] 100
Current [mA] 0...+20, ripple <0,01 % eff., surge free
Impedance [Ohm] 250
Current [mA] 4...20, ripple <0,01 % eff., surge free
<3,6 mA = disable, , >3,8 mA = enble on according to NAMUR NE43
Impedance [Ohm] 250
Differential input max. [V] 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Enable signal [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] 0...+10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. EN 175201-804
Wiring min. [mm²] 7 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply
is to be switched off by a suitable switching element with sufficient reliability.
Installation recommendations
The maximum pilot flow is given in the technical data. At insufficient pilot oil supply – e.g. because of long distances
and/or small diameters – an accumulator can be connected to port XX. See selection guide for correct dimensions.
Selection guide
Max. operating pressure Recommended precharge
Size Capacity [l] Product type Accu port XX
[bar] pressure [bar]
NG40 0.162 ADE016-25R 250 126 G 1/2
NG50 0.243 ADE032-21R 210 126 G 1/2
NG63 0.405 ADE050-21R 210 126 G 3/4
NG80 0.647 ADE075-21R 210 126 G 3/4
NG100 0.944 ADE100-21R 210 126 G 3/4
NG125 on request G1
PG13.5
ID no. 5004072
NG25
224
174
P
96
76
67
71
Note:
Accu port XX and
147 85 Ø34 suction port SP
~277 Ø45 non-existent
NG32
NG Bolt kit -
NBR FPM
25 BK504 4 x M12x100 ISO 4762-12.9 108 Nm SK-TDP025EN30 SK-TDP025EV30
32 BK529 4 x M16x100 ISO 4762-12.9 264 Nm SK-TDP032EN30 SK-TDP032EV30
NG40
NG50
NG Bolt kit -
NBR FPM
40 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TDP040EN30 SK-TDP040EV30
50 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TDP050EN30 SK-TDP050EV30
NG63
NG Bolt kit -
NBR FPM
63 BK518 4 x M30x160 ISO 4762-12.9 1775 Nm SK-TDP063EN30 SK-TDP063EV30
NG80
NG Bolt kit -
NBR FPM
80 BK530 8x M24x160 ISO 4762-12.9 890 Nm SK-TDP080EN30 SK-TDP080EV30
NG100
NG Bolt kit -
NBR FPM
100 BK531 8x M30x150 ISO 4762-12.9 1775 Nm SK-TDP100EN30 SK-TDP100EV30
NG125
NG Bolt kit -
NBR FPM
125 BK537 8x M36x180 ISO 4762 3100 Nm SK-TDP125EN30 SK-TDP125EV30
Code: ISO 7368-B*-*-2-A/B Code: ISO 7368-B*-*-2-A (except for size NG125)
NG25 to NG63 NG80 to NG125
Location pin t10 Thread depth t6 Location pin t10 Thread depth t6
m4
35°
45
d7 °
d6
d7
m3
22,5°
d5
X Y X Y
m1
b1
b1
d5
m1
d6
m1
m2 m2
b1
d1
15° Required surface finish:
1 2
t7
1 = √ Rmax16, 2 = √ Rmax8
t5
2
t4
t1
t2
15°
8
d2
d4
1
t8
t3
Features
• Active pilot operated 2-way high-response valve with
shut-off valve
• Flow directions A-B and B-A
• Cavity and mounting pattern according to ISO 7368
(except for size NG125) TEP040
• Fast step responses
• Completely mounted and adapted unit with integrated
electronics
• 8 sizes NG25 up to NG125
• Shut-off function
TEP040
SP
BTA
XX
Function symbol
X Y
Ordering code
TEP E 9 9 C 2 J
2-way high- Slip-in Sinus Flow Seal Accessories Design
response valve cartridge poppet direction series
with LVDT B→A (not required
A→B for ordering)
Nominal Performance Nominal Pilot oil Command Solenoid
size flow (supply external, signal check valve
drain external) 24 V= / 1.25 A
Code Nominal size
025 NG25 Accessories
032 NG32 Code
shut-off valve
040 NG40 0 without position control
050 NG50 7 with position control
063 NG63
080 NG80 Code Command signal
100 NG100 B 0...+10 V
125 NG125 E 0...+20 mA
S 4...+20 mA
Code Performance
VCD® dynamics especially for Code Seal
D
closed loop applications N NBR
VCD® dynamics especially for V FPM
H
controlled applications H for HFC fluid
The DFplus pilot valve is also available with EtherCAT Please order connector separately
interface, see chapter 3, D*FP and D*1FP with EtherCAT. Angle female connector must be used for NG25 to NG50.
Performance curves
Characteristic flow/signal line
Opening point factory set to 3 % Flow at different ∆p Qactual = Qnominal • ∆ pactual / ∆ pnominal
Characteristic curve measured with HLP46 at 50 °C.
TEP UK.indd CM 16.04.15
General
Design Proportional throttle valve, slip-in cartridge according to ISO 7368 (except for size NG125)
Nominal size DIN NG25 NG32 NG40 NG50 NG63 NG80 NG100 NG125
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 75
Weight [kg] 11 13 15 26 52 105 157 193
Vibration resistance [g] 10 sinus 5...2000 Hz acc. IEC 68-2-6
30 random noise 20...2000 Hz acc. IEC 68-2-36
15 shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports A, B, X and SP up to 350; XX observe accumulator pressure rating;
port Y: max. 35
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity recommended [cSt] / [mm²/s] 30 ... 80
permitted [cSt] / [mm²/s] 20 ... 400
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p= 5 bar [l/min] 420 850 1500 1900 3600 4500 8000 11500
Recommended max. flow [l/min] 800 2000 3000 4500 8000 13000 20000 29000
Flow direction B to A / A to B
Pilot pressure [bar] must be as high as system pressure
Pilot oil supply external via X
drain external via Y
Leakage in pilot valve at 100 bar [ml/min] <400
Pilot valve size NG06 NG10
Max. pilot flow at 140 bar pilot pr. [l/min] 23 30 40 40 70 80 100 100
Static/dynamic
(for optimal dynamics see installation recommendation)
Step response at pilot press. >140 bar [ms] 10.5 12 14 20 17 23 28 46
Frequency response at pilot press. >140 bar
Amplitude -3 dB; 10 % ±5 % [Hz] 95 80 74 66 52 46 41 23
Phase -90°; 10 % +5 % [Hz] 85 63 59 52 56 51 47 45
8 Hysteresis
Sensitivity
[%] < 0.1
[%] < 0.05
Temperature drift [%/K] < 0.025
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage / ripple [V] DC 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 A medium lag
Input signal Voltage [V] 0...+10, ripple < 0.01 % eff., surge free
Impedance [kOhm] 100
Current [mA] 0...+20, ripple <0.01 % eff., surge free
Impedance [Ohm] 250
Current [mA] 4...20, ripple <0.01 % eff., surge free
<3.6 mA = disable, >3.8 mA = enable on according to NAMUR NE43
Impedance [Ohm] 250
Differential input max. [V] 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Enable signal [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] 0...+10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. EN 175201-804
Wiring min. [mm²] 7 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply
is to be switched off by a suitable switching element with sufficient reliability.
Installation recommendations
The maximum pilot flow is given in the technical data. At insufficient pilot oil supply - e.g. because of long distances
and/or small diameters - an accumulator can be connected to port XX. See selection guide for correct dimensions.
Selection guide
Size Capacity [l] Product type Pressure rating [bar] Accu port XX
NG40 0.162 ADE016-25R 126 G 1/2
NG50 0.243 ADE032-21R 126 G 1/2
NG63 0.405 ADE050-21R 126 G 3/4
NG80 0.647 ADE075-21R 126 G 3/4
NG100 0.944 ADE100-21R 126 G 3/4
NG125 on request G1
PG13.5
ID no. 5004072
1 Us 18...42 V
2 Out B: normally open
3 0V
4 Out A: normally closed
8 5 Earth ground
NG25
NG32
NG Bolt kit -
NBR FPM
25 BK504 4 x M12x100 ISO 4762-12.9 108 Nm SK-TEP025EN30 SK-TEP025EV30
32 BK529 4 x M16x100 ISO 4762-12.9 264 Nm SK-TEP032EN30 SK-TEP032EV30
NG40
NG50
NG Bolt kit -
NBR FPM
40 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TEP040EN30 SK-TEP040EV30
50 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TEP050EN30 SK-TEP050EV30
NG63
NG Bolt kit -
NBR FPM
63 BK518 4x M30x160 ISO 4762-12.9 1775 Nm SK-TEP063EN30 SK-TEP063EV30
NG80
NG Bolt kit -
NBR FPM
80 BK530 8x M24x160 ISO 4762-12.9 890 Nm SK-TEP080EN30 SK-TEP080EV30
NG100
NG Bolt kit -
NBR FPM
100 BK531 8x M30x150 ISO 4762-12.9 1775 Nm SK-TEP100EN30 SK-TEP100EV30
NG125
NG Bolt kit -
NBR FPM
125 BK537 8x M36x180 ISO 4762-12.9 3100 Nm SK-TEP125EN30 SK-TEP125EV30
Code: ISO 7368-B*-*-2-A/B Code: ISO 7368-B*-*-2-A (except for size NG125)
NG25 to NG63 NG80 to NG125
Location pin t10 Thread depth t6 Location pin t10 Thread depth t6
m4
35°
45
d7 °
d6
d7
m3
22,5°
d5
X Y X Y
m1
b1
b1
d5
m1
d6
m1
m2 m2
b1
d1
15° Required surface finish:
1 2
t7
1 = √ Rmax16, 2 = √ Rmax8
t5
2
t4
t1
t2
15°
8
d2
d4
1
t8
t3
Function
TPQ has a 2-stage design consisting of a DFplus pilot
valve and a main stage with spool and LVDT.
With the DFplus pilot valve the TPQ achieves extremely
TPQ 040
fast response times: from 7 ms (NG25) up to 20 ms
(NG80) with an accuracy of <0.1 % of the nominal flow.
The pilot valve actively controls the spool – independent Features
of the pressure conditions in the main ports. • Active pilot operated 3-way high-response valve
It is basically required that the pilot pressure is at the • Cavity according to Parker house norm
level of the system pressure. At low system pressure the • Fast step response
pilot pressure should be min. 140 bar, when high valve • Flow direction A to T and P to A
dynamics are desired. • Completely mounted adapted unit with integrated
The integrated electronics in the pilot of the TPQ has two electronics
control loops for the main cone and the pilot spool. • 6 sizes NG25 up to NG80
TPQ 040 P
Function symbol
Fail safe position spool type P
BTA
XX
X Y
Ordering code
TPQ W H 2 5 2 0
3-way high- Nominal Parker Closed loop, Linear Nominal Spool Pilot oil Seal Input Standard Design
response size Slip-in VCD® per- spool flow type supply ex- signal electronics series
valve with cartridge formance, ternal, drain (not required
LVDT integrated external for ordering)
electronics
Code Nominal size Code Signal range
025 NG25 B 0...±10 V
032 NG32 E 0...±20 mA
040 NG40 S 4...+20 mA
050 NG50
063 NG63
080 NG80 Code Seal
N NBR
Zerolap V FPM
Spool type H for HFC fluid
Code Input signal Fail save
- 0 +
A
P P→A
P T
A
T A→T
P T
The DFplus pilot valve is also available with EtherCAT Please order connector separately
interface, see chapter 3, D*FP and D*1FP with EtherCAT. Angle female connector must be used for NG25 to NG50.
Performance curves
Characteristic flow/signal line
General
Design Proportional throttle valve, slip-in cartridge
Nominal size DIN NG25 NG32 NG40 NG50 NG63 NG80
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTFD value 1) [years] 75
Weight [kg] 11 13 15 26 52 105
Vibration resistance [g] 10 sinus 5...2000 Hz acc. IEC 68-2-6
30 random noise 20...2000 Hz acc. IEC 68-2-36
15 shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports A, P, T, X up to 350, XX 2) observe accumulator pressure rating; port Y: max. 35
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity recommended [cSt]/[mm²/s] 30...80
permitted [cSt]/[mm²/s] 20...400
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 5 bar [l/min] 200 320 550 800 1450 2700
Recommended max. flow [l/min] 500 1000 1600 2250 3500 6500
Nominal overlap [%] < 1.5
Flow direction A to T or P to A
Pilot pressure [bar] must be as high as system pressure
Pilot oil supply external via X
drain external via Y
Leakage in pilot valve at 100 bar [ml/min] < 400
Leakage in main stage at 100 bar [l/min] NG32 to 63 <2.5; NG80 <4.0
Pilot valve size NG06 NG10
Max. pilot flow at 140 bar pilot press. [l/min] 25 25 25 25 50 60
Static/dynamic
(for optimal dynamics see installation recommendation)
Step response at pilot press. >140 bar [ms] 7 11 11 18 19 20
Frequency response at pilot press. >140 bar
8
Amplitude -3 dB; ±5 % [Hz] 210 105 70 45 35 30
Phase -90°; ±5 % [Hz] 170 125 110 95 75 70
Hysteresis [%] < 0.1
Sensitivity [%] < 0.05
Temperature drift of center position [%/K] < 0.025
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage / ripple [V] DC 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 A medium lag
Input signal Voltage [V] +10...0...-10, ripple < 0,01 % eff., surge free
Impedance [kOhm] 100
Current [mA] 20...0...-20, ripple <0,01 % eff., surge free
Impedance [Ohm] 250
Current [mA] 4...12...20, ripple <0,01 % eff., surge free
<3,6 mA = disable, , >3,8 mA = enble on according to NAMUR NE43
Impedance [Ohm] 250
Differential input max. [V] 30 for terminal D and E against PE (terminal G),
[V] 11 for terminal D and E against 0V (terminal B)
Diagnostic signal [V] 0...±10 rated max. 5 mA
Enable signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. EN 175201-804
Wiring min. [mm2] 7x1.0 (AWG16) overall braid shield
Wiring length [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply
is to be switched off by a suitable switching element with sufficient reliability.
2) Accu port XX: Please contact Parker for installation recommendation.
PG13.5
ID no. 5004072
ID no. 5005160
NG25
NG32
NG Bolt kit -
NBR FPM
25 BK504 4x M12x100 ISO 4762-12.9 108 Nm SK-TPQ025EN30 SK-TPQ025EV30
32 BK529 4x M16x100 ISO 4762-12.9 264 Nm SK-TPQ032EN30 SK-TPQ032EV30
TPQ UK.INDD CM 16.04.15
NG40
NG50
NG Bolt kit -
NBR FPM
40 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TPQ040EN30 SK-TPQ040EV30
50 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TPQ050EN30 SK-TPQ050EV30
TPQ UK.INDD CM 16.04.15
NG63
NG Bolt kit -
NBR FPM
63 BK518 4x M30x160 ISO 4762-12.9 1775 Nm SK-TPQ063EN30 SK-TPQ063EV30
NG80
NG Bolt kit -
NBR FPM
80 BK530 8x M24x160 ISO 4762-12.9 517 Nm SK-TPQ080EN30 SK-TPQ080EV30
TPQ UK.INDD CM 16.04.15
√ Rmax25, 1 = √ Rmax8
+3
Size m1 ±0.2 m2 ±0.2 m3 ±0.2 m4 ±0.2 t1 +1 t2 ±0.2 t3 ±0.2 t4 t5 t6 t7 ±0.2 t8 ±0.2 t9 t10 t11 t12
25 58 33 29 16 103 89 +0.3 56 11.5 15 17 78 43.5 2.5x15° 2.5x15° 10 35
32 70 41 35 17 100 85 43 13.5 16 18 71 28.5 2.5x15° 2.5x15° 10 35
40 85 50 42.5 23 125 105 54 15 18 21 88 34 3x15° 3x15° 10 45
50 100 58 50 30 165 143 83 18 18 21 122 53 4x15° 3x15° 10 45
63 125 75 62.5 38 195 165 83.5 25 29.5 33 138.5 50 4x15° 4x15° 10 65
80 200 – – – 245 215 123 25 27 60 181 87 5x15° 5x15° 10 50
SAE61
SAE62
2-port
3-port
DIN / ISO ¾ 1 1¼ 1½
content09.INDD CM 03.03.15
Features
• Pilot operated with manual adjustment R5V 2-port R5V 3-port
• R5V with 2-port body
- 3 sizes (SAE ¾", 1", 1¼")
- SAE61 flange
• R5V with 3-port body
- 4 sizes (SAE ¾", 1", 1¼", 1½")
- SAE61 and SAE62 flange
• 3 pressure stages
• 3 adjustment modes
- Hand knob external drain internal drain
- Acorn nut with lead seal
- Cylinder lock R5V 2-port R5V 3-port
• With optional vent function
R5V A
Pressure Nominal SAE Pilot Pressure Adjust- Pilot Switching Solenoid Design Seals Design Options
relief valve size Interface ports stages ment oil type voltage series
(not required
for ordering)
9
240 V / 60 Hz
1 up to 105 bar
3 up to 210 bar
5 3) up to 350 bar
Code Switching type
Standard w/o
omit
vent function
Code Adjustment Solenoid not activ.
09
1 Hand knob unpress. circulation
Acorn nut Solenoid activated
3 11
with lead seal unpress. circulation
4 Cylinder lock
Pilot oil
Code Drain line
Further options on request 2 internal
6 external from Y1-port
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼") 12 (1½")
Mounting Flanged according to SAE61 and SAE62
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight R5V 2-port [kg] 4.0 4.6 5.9 —
R5V 3-port [kg] 3.6 4.6 5.2 8.0
Hydraulic
Max. operating pressure [bar]
SAE61 Ports A, B 350 350 280 210
Port Y1 30 30 30 30
SAE62 Ports A, B 350 350 350 350
Port Y1 30 30 30 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
[V] 120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70/70 VA 70/70 VA
in rush [W] 32.7 31 31.9 28.2 280/290 VA 280/290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
9
p/Q performance curve Minimum pressure curve
SAE61
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
NG B1 H1 H2 H3 H4 L1 L2 L3 d1 d2
06 60 131.6 37 47.6 90 24.6 22.2 152 19 10.5
08 60 137.6 45 52.4 96 26.5 26.2 171 25 10.5
10 75 150.6 48 58.7 109 34.0 30.2 179 32 12.5
Port size
Port Function
R5V06 R5V08 R5V10
A Pressure ¾" SAE61 1" SAE61 1¼" SAE61
B Tank ¾" SAE61 1" SAE61 1¼" SAE61
Y1 External drain G¼" G¼" G¼"
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
SAE61
9 NG
06
B1
60
B2
22.2
H1
119
H2
29.5
H3
22.2
H4
81
H5
41
H6
47.6
L1
50.3
L2
47.6
L3
63
L4
60
L5 d1
152 19
d2
10.5
d3
19
d4 (option 152)
3/8”-16 UNC (M10)
t1
20
08 60 26.2 141 30.5 26.2 103 47 52.4 55.8 52.4 65 62 149 25 10.5 25 3/8”-16 UNC (M10) 23
10 75 30.2 151 37.5 30.2 113 65 58.7 57.8 58.7 61 68 150.5 32 12.5 30 7/16”-14 UNC (M12) 22
12 80 35.7 178 72 35.7 140 73 69.8 37.3 69.8 92.5 59.2 171.2 38 13.5 38 1/2”-13 UNC (M12) 27
SAE62
NG B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 d4 (option 152) t1
06 60 23.8 119 29.5 23.8 81 41 50.8 50.3 50.8 63 60 152 19 10.5 19 3/8”-16 UNC (M10) 20
08 60 27.8 141 30.5 27.8 103 47 57.2 55.8 57.2 65 62 149 25 12.5 25 7/16”-14 UNC (M10)1) 22
10 75 31.8 151 37.5 31.8 113 65 66.7 57.8 66.7 61 68 150.5 32 13.5 30 1/2”-13 UNC (M12) 24
12 80 36.5 178 72 36.5 140 73 79.4 37.3 79.4 92.5 59.2 171.2 38 17 38 5/8”-11 UNC (M16) 33
Port size
Port Function
R5V06 R5V08 R5V10 R5V12
A (2) Pressure ¾" SAE61/62 1" SAE61/62 1¼" SAE61/62 1½" SAE61/62
B Tank ¾" SAE61/62 1" SAE61/62 1¼" SAE61/62 1½" SAE61/62
X1 External pilot port 2) G¼" G¼" G¼" G¼"
Y1 External drain G¼" G¼" G¼" G¼"
M Pressure gauge G¼" G¼" G¼" G¼"
1) T-port SAE61.
2) Closed when supplied.
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
A A A A
Z Z
A A Z Z
X Y X Y
X Y X Y
11
Y Y1
B B Y1
B B
A A A A
Z Z
A A Z Z
X Y X Y
X Y X Y
09
Y Y1
B B Y1
B B
Features
• Pilot operated unloading valve
• 3-port body with SAE61 flange
• 4 sizes (SAE ¾", 1", 1¼", 1½")
• 3 pressure stages
• 3 adjustment modes
- Hand knob
- Acorn nut with lead seal
- Cylinder lock
R5U 3-port internal drain R5U 3-port external drain
• With optional vent function
R5U 9 A
Pressure Nominal SAE61 3-port body Pressure Adjust- Pilot oil Switching Solenoid Design Seals Options
unloading size interface M, Y1, X = G¼" stages ment type voltage series
valve
Code Options
Code Port size Vent function
008 3)
with slow unloading
06 SAE ¾"
3-port body
08 SAE 1" 152
with metric threads
10 SAE 1¼"
12 SAE 1½"
Code Seals
1 NBR
SAE61
5 FPM
Code Size Max. pressure [bar]
3 12 210
4 10 280 Code Solenoid voltage
5 06/08 350 Standard w/o
omit
vent function
G0R 12 V=
Pressure Pressure G0Q 24 V=
Code
stages [bar] differential
GAR 2) 98 V=
1 up to 105 28 %
GAG 2) 205 V=
3 up to 210 28 %
110 V / 50 Hz
5 1) up to 350 15 % W30
120 V / 60 Hz
230 V / 50 Hz
W31
Code Adjustment 240 V / 60 Hz
1 Hand knob
3 Acorn nut with lead seal Code Switching type
4 Cylinder lock omit Standard w/o vent function
Solenoid not activ.
09
unpress. circulation
11
Solenoid activated
unpress. circulation 9
Further options on request Pilot oil
Code Pilot Drain
External via
4 External
port X1 or X2
External via
5 Internal
port X1 or X2
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼") 12 (1½")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 3.6 4.6 5.2 8.0
Hydraulic
Max. operating pressure [bar]
Ports A, B, X 350 350 280 210
Ports Y, Y1 30 30 30 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
[V] 120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70/70 VA 70/70 VA
in rush [W] 32.7 31 31.9 28.2 280/290 VA 280/290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
9
p/Q performance curve Minimum pressure curve
Dimensions R5U
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
NG B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 d4 t1 d5 L6 H7 H8
06 60 22.2 119 29.5 22.2 81 41 47.6 50.3 47.6 63 60 152 19 10.5 19 3/8”-16 UNC 20 3.0 – – –
08 60 26.2 141 30.5 26.2 103 47 52.4 55.8 52.4 65 62 149 25 10.5 25 3/8”-16 UNC 23 3.0 – – –
10 75 30.2 151 37.5 30.2 113 65 58.7 57.8 58.7 61 68 150.5 32 12.5 30 7/16”-14 UNC 22 3.0 – – –
12 80 35.7 178 35.5 35.7 140 73 69.8 37.3 69.8 92.5 59.2 171.2 38 13.5 38 1/2”-13 UNC 27 3.0 22.4 27.2 72
Port size
Port Function
R5U06 R5U08 R5U10 R5U12
A (2) Pressure ¾" SAE61 1" SAE61 1¼" SAE61 1½" SAE61
B Tank ¾" SAE61 1" SAE61 1¼" SAE61 1½" SAE61
X1 External pilot port 1) G¼" G¼" G¼" G¼"
Y1 External drain G¼" G¼" G¼" G¼"
M Pressure gauge G¼" G¼" G¼" G¼"
1) Closed when supplied.
R5U UK.INDD CM 16.03.15
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
A A A A
Z Z
X Y X Y
11 X1 X1
or or
X2 B Y X2 B Y1
A A A A
Z Z
X Y X Y
09 X1 X1
or or
X2 B Y X2 B Y1
Features
• Pilot operated with manual adjustment
• 3-port body with SAE61 flange
• 3 sizes (SAE ¾", 1", 1¼")
• 3 pressure stages
• 2 adjustment modes
- Hand knob
- Acorn nut with lead seal
• Optional with vent function (on request)
Ordering code
R5S 9 6 A 152
Pressure Nominal SAE61 3-port Pressure Adjust- External Design Seals 3-port body
sequence size interface body stages ment drain from series with metric
valve (Y1, M = G¼") Y1 port threads
9 Technical data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 3.6 4.6 5.2
Hydraulic
Max. operating pressure [bar]
Ports A, B 350 350 280
Ports Y, Y1 30 30 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
P1 = setting pressure
P2 = operating pressure
Time and pressure underlap depend on the characteristics of the specific system.
9
SAE61
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
NG B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 d4 (option 152) t1
06 60 22.2 119 29.5 22.2 81 41 47.6 50.3 47.6 63 60 152 19 10.5 19 3/8”-16 UNC (M10) 20
08 60 26.2 141 30.5 26.2 103 47 52.4 55.8 52.4 65 62 149 25 10.5 25 3/8”-16 UNC (M10) 23
10 75 30.2 151 37.5 30.2 113 65 58.7 57.8 58.7 61 68 150.5 32 12.5 30 7/16”-14 UNC (M12) 22
Port size
Port Function
R5S06 R5S08 R5S10
A (2) Pressure ¾" SAE61 1" SAE61 1¼" SAE61
B Secondary port ¾" SAE61 1" SAE61 1¼" SAE61
X1 External pilot port 1) G¼" G¼" G¼"
Y1 External drain G¼" G¼" G¼"
M Pressure gauge G¼" G¼" G¼"
1) Closed when supplied.
R5S UK.INDD CM 16.04.15
Features
• Pilot operated with manual adjustment
• Normally closed to avoid unintended motion
• 2-port body with SAE61 flange
• 3 sizes (SAE ¾", 1", 1¼")
• 3 pressure stages
• 3 adjustment modes
- Hand knob
- Acorn nut with lead seal
- Cylinder lock
• With optional vent function
• Flow direction B ® A
R5R 8 6 A
Pressure Nominal SAE61 2-port Pressure Adjust- External Switching Solenoid Design Seals Options
reducing size Interface body stages ment drain from type voltage series
valve (X1, Y1 = G¼") Y1 port
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 4.0 4.6 5.9
Hydraulic
Max. operating pressure [bar]
Ports A, B, X1 350 350 280
Port Y1 30 30 30
Flow direction B®A
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 500
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical
Duty ratio 100% ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
[V] 120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [W] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [W] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [ms] 32.7 31 31.9 28.2 70/70 VA 70/70 VA
in rush 32.7 31 31.9 28.2 280/290 VA 280/290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
30
Pressure p [bar]
25
20
15
10
5
0 50 100 150
Flow Q [l/min]
30
Pressure p [bar]
25
20
15
10
5
80
Pressure p [bar]
70
60
50
40
30
20
10
R5R
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
NG B1 H1 H2 H3 H4 L1 L2 L3 d1 d2
06 60 131.6 37 47.6 90 24.6 22.2 152 19 10.5
08 60 137.6 45 52.4 96 26.5 26.2 171 25 10.5
10 75 150.6 48 58.7 109 34.0 30.2 179 32 12.5
Port size
Port Function
R5R06 R5R08 R5R10
B Inlet pressure ¾" SAE61 1" SAE61 1¼" SAE61
A Reduced outlet pressure ¾" SAE61 1" SAE61 1¼" SAE61
Y1 External drain G¼" G¼" G¼"
X1 Pressure gauge G¼" G¼" G¼"
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
Z
B
X Y
11
X1 Y1
A
Z
B
X Y
09
X1 Y1
A
Features
• Continuous adjustment by proportional solenoid
R5V*P2 2-port R5V*P2 3-port
• R5V with 2-port body
- 3 sizes (SAE ¾", 1", 1¼")
- SAE61 flange
• R5V with 3-port body
- 4 sizes (SAE ¾", 1", 1¼", 1½")
- SAE61 and SAE62 flange
• 3 pressure stages
• With mechanical maximum pressure adjustment
R5V P2 G0R A
Proportional Nominal SAE Pilot Pressure Adjust- Pilot Propor- Solenoid Design Seals Design Options
pressure size interface ports stages ment oil tional voltage 12 V series
relief valve pressure 2.1 A 4) (not required
control for ordering)
General
Size 06 (¾") 08 (1") 10 (1¼") 12 (1½")
Mounting Flanged according to SAE61 (size 12 = SAE62)
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight R5V 2-port [kg] 5.8 6.4 7.7 —
R5V 3-port [kg] 5.4 6.4 7.0 9.8
Hydraulic
Max. operating pressure [bar]
SAE61 Ports A, B 350 350 280 210
Port Y1 30 30 30 30
SAE62 Ports A, B 350 350 350 350
Port Y1 30 30 30 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
Viscosity recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (proportional solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R
Supply voltage [V] 12 V =
Max. current [A] 2.1
Coil resistance at 20 °C [Ohm] 4.28
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
9
Minimum pressure curve 1)
R5V06*P2 R5V08*P2 R5V10*P2
1) The performance curves are measured with external drain. For internal drain the tank pressure has to be added to curve.
R5V*P2 2-port
9
SAE61
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
Prop. section P2 * S26-58473-0 S26-58473-5
NG B1 H1 H2 H3 H4 H5 L1 L2 L3 d1 d2
06 60 175 37 47.6 90 137 24.6 22.2 174 19 10.5
08 60 181 45 52.4 96 143 26.5 26.2 193.6 25 10.5
10 75 194 48 58.7 109 156 34.0 30.2 201 32 12.5
Port size
Port Function
R5V06 R5V08 R5V10
A Pressure ¾" SAE61 1" SAE61 1¼" SAE61
B Tank ¾" SAE61 1" SAE61 1¼" SAE61
Y1 External drain G¼" G¼" G¼"
* Please combine seal kit of one size with seal kit of Prop. section P2 for complete seal kit.
R5V*P2 3-port
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
Prop. section P2 * S26-58473-0 S26-58473-5
9
SAE61
NG B1 B2 H1 H2 H3 H4 H5 H6 H7 L1 L2 L3 L4 L5 d1 d2 d3 d4 (option 152) t1
06 60 22.2 166 29.5 22.2 81 41 47.6 128 50.3 47.6 63 60 174.6 19 10.5 19 3/8”-16 UNC (M10) 20
08 60 26.2 188 30.5 26.2 103 47 52.4 150 55.8 52.4 65 62 177 25 10.5 25 3/8”-16 UNC (M10) 23
10 75 30.2 198 37.5 30.2 113 65 58.7 160 57.8 58.7 61 68 179.1 32 12.5 30 7/16”-14 UNC (M12) 22
12 80 35.7 225 72 35.7 140 73 69.8 187 37.3 69.8 92.5 59.2 186.8 38 13.5 38 1/2”-13 UNC (M12) 27
SAE62
NG B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 d4 (option 152) t1
06 60 23.8 119 29.5 23.8 81 41 50.8 50.3 50.8 63 60 152 19 10.5 19 3/8”-16 UNF (M10) 20
08 60 27.8 141 30.5 27.8 103 47 57.2 55.8 57.2 65 62 149 25 12.5 25 7/16”-14 UNC (M10)1) 22
10 75 31.8 151 37.5 31.8 113 65 66.7 57.8 66.7 61 68 150.5 32 13.5 30 1/2”-13 UNC (M12) 24
12 80 36.5 178 72 36.5 140 73 79.4 37.3 79.4 92.5 59.2 171.2 38 17 38 5/8”-11 UNC (M16) 33
Port size
Port Function
R5V06 R5V08 R5V10 R5V12
A (2) Pressure ¾" SAE61/62 1" SAE61/62 1¼" SAE61/62 1½" SAE61/62
B Tank ¾" SAE61/62 1" SAE61/62 1¼" SAE61/62 1½" SAE61/62
Y1 External drain G¼" G¼" G¼" G¼"
M Pressure gauge G¼" G¼" G¼" G¼"
* Please combine seal kit of one size with seal kit of Prop. section P2 for complete seal kit.
1) T-port SAE61.
Features
• Continuous adjustment by proportional solenoid
• 2-port body with SAE61 flange
• 3 sizes (SAE ¾", 1", 1¼")
• 3 pressure stages
• With mechanical maximum pressure adjustment
Ordering code
R5R 8 6 P2 G0R A
9
Pressure Nominal SAE61 Body Pressure Adjust- External Propor- Solenoid Design Seals Options
reducing size interface 2-port stages ment drain from tional voltage 12 V series
valve (X1, Y1 = G¼") Y1-port pressure 2.1 A
control
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 5.8 6.4 7.7
Hydraulic
Max. operating pressure Ports A, B, X1 [bar] 350 350 280
Port Y1 [bar] 30 30 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 500
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (proportional solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R
Supply voltage [V] 12 V =
Max. current [A] 2.1
Coil resistance at 20 °C [Ohm] 4.28
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
9
Reduced pressure pA vs. flow Q
R5R10*P2 1) Minimum pressure curve
80
Pressure p [bar]
70
60
50
40
30
20
10
9
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
Prop. section P2 * S26-58473-0 S26-58473-5
NG B1 H1 H2 H3 H4 H5 L1 L2 L3 d1 d2
06 60 175 37 47.6 90 137 24.6 22.2 174 19 10.5
08 60 181 45 52.4 96 143 26.5 26.2 193.6 25 10.5
10 75 194 48 58.7 109 156 34.0 30.2 201 32 12.5
Port size
Port Function
R5R06 R5R08 R5R10
B Inlet pressure ¾" SAE61 1" SAE61 1¼" SAE61
A Reduced outlet pressure ¾" SAE61 1" SAE61 1¼" SAE61
Y1 External drain G¼" G¼" G¼"
X1 Pressure gauge G¼" G¼" G¼"
* Please combine seal kit of one size with seal kit of Prop. section P2 for complete seal kit.
R5RP2 UK.INDD CM 03.03.15
Features
• Leak-free seat valve design
• 2- and 3-port bodies
• SAE61 flange
• Numerous pilot options
• 4 sizes, SAE ¾", 1", 1 ¼", 1 ½"
• 6 poppet types
D5S 2-port D5S 3-port
D5S B
Seat Nominal Body Pilot body Pilot Sleeve Spool Spring Switching Solenoid Design Seals Options
valve size configuration cap type type voltage series
BK
and position control 3) with amplifier
VV01 code 12 and shuttle valve code CA
open bore closed bore orifice Ø 1.2 and position control 3) with amplifier
VV01 code 10 and shuttle valve code DA
BN
and position control 3) with amplifier
Code Sleeve
VV01 code 12 and shuttle valve code DA
1 AA = 95 %, AB = 5 % BQ
and position control 3) with amplifier
3 AA = 60 %, AB = 40 %
BC VV01 code 10 and position control 3) with amplifier
BE VV01 code 12 and position control 3) with amplifier
Code Size Poppet type Sleeve BA Position control 3) with amplifier
06, With closed bottom and 15° chamfer Position control 3) with amplifier
1 1 BF
08,10,12 (pZ max. = pA +20 bar) and shuttle valve code CA
06 With 0.8 dia. orifice at the bottom and 15°chamfer 1 Position control 3) with amplifier
2 BL
08, 10 With 1.2 dia. orifice at the bottom and 15°chamfer 1 and shuttle valve code DA
06,
4 With closed bottom and 45° chamfer 1, 3
08,10,12 Spring (approx. cracking pressure [bar])
A 2) 08, 10, 12 Safety spool (for end position control only) 3 Sleeve Code 1 Sleeve Code 3
Code
B 2) 08, 10, 12 Throttle spool, 10° chamfer 3 A -> B A -> B B -> A
C 2) 08, 10, 12 Throttle spool, 3° chamfer 3 D5S06 D5S08/12 D5S06 D5S08/12 D5S06 D5S08/12
1 2.8 3.5 6.5 6.5 9.5 11.0
2 0.5 0.5 1.0 1.0 1.5 1.7
3 0.3 0.3 0.6 0.6 0.9 1.0
4 2.2 2.2 4.0 3.5 5.5 6.0
1) D5S 3-port only.
2)
5 — 9.0 — 16.0 — 28.0
Springs 2, 3 and 6 only. 6 1.2 1.2 2.0 2.2 3.0 3.8
3) Position control for D5S08/10 only. Spring 2 or 4. Spool A and sleeve 3.
4) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply. 7 3.0 — 8.0 — 12.0 —
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼") 12 (1½")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight D5S 2-port [kg] 3.6 4.1 5.4 —
D5S 3-port [kg] 3.4 4.4 5.0 7.8
Hydraulic
Max. operating pressure [bar]
SAE61 Ports A, B 350 350 280 210
Port Y1 30 30 30 30
Nominal flow [l/min] 180 360 600 800
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
Supply voltage [V] 12 V = 24 V = 98 V = 205 V = 110 at 50 Hz 230 at 50 Hz
120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
in rush [W] 32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Z1
Z1 VV01 Z1 VV01 Z1 VV01
AZ de-energized: closed
X1 AZ AZ
B Z Y
AB AA AB AB
A A AA AA
A B A B
Z1
Selection of cartridges
Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet B/C
Z Z Z Z Z Z
B B B B B B
A A A A A A
1 : 1.05 1 : 1.05 1 : 1.05 1 : 1.67 1 : 1.67 1 : 1.67
AA = 0.95 AC AA = 0.95 AC AA = 0.95 AC AA = 0.6 AC AA = 0.6 AC AA = 0.6 AC
AB = 0.05 AC AB = 0.05 AC AB = 0.05 AC AB = 0.4 AC AB = 0.4 AC AB = 0.4 AC
15° chamfer 15° chamfer 45° chamfer 45° chamfer 45° chamfer 45° chamfer
orifice safety spool throttle spool
D5S UK.INDD CM 16.04.15
D5S 2-port
Seat entry Annular entry
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
NG l1 l2 l3 b1 h1 h2 h3 h4 d1 d2
06 77 101.0 22.2 60 37 47.6 90 127.6 19 10.5
08 94 120.5 26.2 60 45 52.4 96 133.6 25 10.5
10 94 128.0 30.2 75 48 58.7 109 146.6 32 12.5
Port size
Ports Function
D5S06 D5S08 D5S10
A Inlet or outlet ¾" SAE61 1" SAE61 1¼" SAE61
B Outlet or inlet ¾" SAE61 1" SAE61 1¼" SAE61
X1 External pilot port G¼" G¼" G¼"
Y1 External pilot drain G¼" G¼" G¼"
D5S 3-port
9 Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
NG l1 l2 l3 l4 b1 b2 h1 h2 h3 h4 h5 h6 d1 t1 d2 d3
06 49 47.6 56 63 22.2 60 41 47.6 29.5 22.2 82 119 3/8" UNC 20 19 10.5
08 55 52.4 58 65 26.2 60 47 52.4 30.5 26.2 103 141 3/8" UNC 23 25 10.5
10 57 58.7 64 61 30.2 75 65 58.7 37.5 30.2 113 150 7/16" UNC 22 30 12.5
12 37 69.8 55 93 35.7 80 73 69.8 72 35.7 140 178 1/2" UNC 27 38 13.5
Port size
Ports Function
D5S06 D5S08 D5S10 D5S12
A (2x) Inlet or outlet ¾" SAE61 1" SAE61 1¼" SAE61 1½" SAE61
B Outlet or inlet ¾" SAE61 1" SAE61 1¼" SAE61 1½" SAE61
X1 1) External pilot port G¼" G¼" G¼" G¼"
Y1 External pilot drain G¼" G¼" G¼" G¼"
M Pressure gauge G¼" G¼" G¼" G¼"
Example: pilot oil external from X1, pilot drain internal out of B
Function
Solenoid de-energized:
pilot oil from X1 to Z blocks the connection
from A to B or B to A.
Solenoid energized:
pilot pressure from X1 is blocked in the VV01.
The oil in Z is internally drained to port B. Al-
lowing flow from A to B, while B to A remains
blocked.
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
VV01
Code CB
9
or CD
shuttle valve
(pilot oil from A and B)
Z1
X1 B
body version
series D5S 3-Port
A A
Y1
X-Y
cap
X Z Y
VV01
Code DB
or DD
shuttle valve 1)
Z1
X1 B
body version
Shuttle valve only in connection with vent valve VV01.
series D5S 3-Port
A A
D5S 2-port
Seat entry Annular entry
9
D5S 3-port with with solenoid valve VV01 and shuttle valve
9
Seat entry Annular entry
Features
• Spool type proportional throttle valve
• SAE61 flange
• Maximum flow 380 l/min
• 3 sizes, SAE 3/4“, 1“, 1 1/4“
• Load compensated flow in combination with
R5A/R5P
Ordering Code
F5C 4 3 X 0 C
Proportional Nomi- Pilot flow SAE61 Pilot Spool Proportional Pilot Acces- Design Seals Design Options
throttle valve nal size and interface ports type solenoid connection sories series
response G¼" 16 V/1.05 A (not required
for ordering)
9
Pilot connection explanation
B A A
A B1 A B
X2
X2
X1
X1 Y1
Y1
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
Weight [kg] 3.9 4.1 5.8
Hydraulic
Max. operating pressure
Ports A, B, X1, X2, X3 [bar] 350 300 280
Ports Y1, Y2 [bar] 70
Max. pressure drop (from A to B) [bar] 21
Nominal flow [l/min] 95 190 380
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage [V] 16
Current consumption [A] 1.05
Resistance [Ohm] 11.3
Response time [ms] see ordering code
Characteristic curves
M3
Internal pilot pressure connection (X1)
(for use with R5A - 2-port compensator)
Optional external
pilot pressure
connection (X3)
X1 out (B)
d3
b1
11
h5 in (A)
External pilot drain (Y2)
200 36
36 4.1
d3
d2 3
h4
h6
9
3
3-port compensator)
h2
d1
l1
62.1
Seal kits
NG NBR FPM
06 / 08 / 10 S26-58484-0 S26-58484-5
l1 b1 h1 h2 h3 h4 h5 h6 d1 d2 d3
F5C06 47.6 60 68.2 26 22.2 103.2 183 20.8 19 10.5 G¼"
F5C08 52.4 60 73.6 29 26.2 108.6 187 24.3 25 10.5 G¼"
F5C10 58.7 75 83.5 36.5 30.2 118.5 198 29.3 32 12.5 G¼"
Features
• Seated type 2-way pressure compensator
• SAE61 flange
• 8.4 bar control pressure Pilot connection on
• 3 sizes, SAE 3/4“, 1“, 1 1/4“ inlet flange to link
with F5C valve.
• Load compensated flow in combination with F5C
X1
A (B1)
Ordering code 9
R5A 4 1 01 B
SAE 61 interface
Max. pressure
Code Size
[bar]
4 10 280
5 06/08 350
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 3.6 4.3 5.6
Hydraulic
Max. operating pressure Ports A, B, X1 [bar] 350 350 280
Control pressure [bar] 8.4
Nominal flow [l/min] 90 300 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Dimensions
Seal kits
NG NBR FPM
06 S16-91458-0 S16-91458-5
08 S16-91457-0 S16-91457-5
10 S16-91456-0 S16-91456-5
l1 l2 l3 b1 h1 h2 h3 h4 d1 d2
R5A06 22.2 77 101 60 37 47.6 90 128 19 10.5
R5A08 26.2 94 120.5 60 45 52.4 96 134 25 10.5
R5A10 30.2 94 128 75 48 58.7 109 147 32 12.5
R5A UK.INDD CM 16.04.15
Features
• Seated type 3-way pressure compensator
• SAE61 flange
• 8.4 bar control pressure
• Pressure relief function (optionally proportional)
• With optional vent function
• 3 sizes, SAE 3/4“, 1“, 1 1/4“
• Load compensated flow in combination with F5C
R5P
R5P A
3-port Nominal SAE 61 Pilot Pressure Adjust- Pilot Switching Solenoid Design Seals Options
compensator size Interface ports stages ment connection type voltage series
9
unpressure circulation
Code Adjustment
1 Hand knob
Acorn nut with Code Pilot connection
3
lead seal internal PD
2
internal PP 4)
external PD 3)
6
internal PP 4)
1) Y1 port is used in combination with F5C, when the F5C should be drained through the R5P (internal or external drain).
2) R5P10-4*5 up to 280 bar.
3) Through port Y1.1.
4) PP through port X1 in outlet flange.
5) To be used in combination with rectifier plugs at 120 VAC/230 VAC power supply.
6) Further seals on request.
R5P*P2
R5P P2 G0R A
3-port Nominal SAE 61 Pilot Pressure Adjust- Pilot Propor- Solenoid Design Seals Options
compensator size Interface ports stages ment connection tional voltage 12 V series
pressure 2.1 A
control
Code Adjustment
1 Hand knob
Code Pilot ports Port Y1 1)
Acorn nut with
9 plugged 3
G¼" lead seal
P open
1) Y1 port is used in combination with F5C, when the F5C should be drained through the R5P (internal or external drain).
2) R5P10-4*5 up to 280 bar.
3) Through port Y1.1.
4) PP through port X1 in outlet flange.
5) Further seals on request.
R5P
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight R5P [kg] 3.7 4.4 5.3
R5P with VV01 [kg] 5.4 6.1 7.0
Hydraulic
Max. operating pressure Ports A, B [bar] 350 350 280
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid) R5P with VV01
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
in rush [W] 32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
R5P*P2
9 General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE61
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 5.5 6.2 7.1
Hydraulic
Max. operating pressure Ports A, B [bar] 350 350 280
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (proportional solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R
Supply voltage [V] 12 V =
Max. current [A] 2.1
Coil resistance at 20 °C [Ohm] 4.28
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
R5P UK.INDD CM 16.04.15
R5P
9
Seal kits
NG NBR FPM
06 S16-91461-0 S16-91461-5
08 S16-91460-0 S16-91460-5
10 S16-91459-0 S16-91459-5
l1 l2 l3 l4 l5 l6 b1 b2 h1 h2 h3 h4 h5 h6 d1 d2 d3
R5P06 47.6 63 56 148 1 49 60 20 119 81.6 29.5 22.2 41.6 20.8 19 10.5 3/8" UNC
R5P08 52.4 65 58 144.6 5 54.5 60 23 142 103 30.5 26.2 48.6 24.3 25 10.5 3/8" UNC
R5P10 58.7 61 64 146.6 3 56.5 75 22 149 113 37.5 30.2 64.1 29.3 32 12.5 7/16" UNC
Ports
Port size
Port Function
R5P06 R5P08 R5P10
A Inlet/outlet ¾" 1" 1¼"
B2 Tank ¾" 1" 1¼"
X2 Internal pilot pressure M3 M3 M3
X2.2 External pilot pressure G¼" G¼" G¼"
Y1 Internal pilot drain M3 M3 M3
Y1.1 External pilot drain G¼" G¼" G¼"
M Pressure gauge G¼" G¼" G¼"
R5P UK.INDD CM 16.04.15
R5P*P2
Note:
On initial start up and after long shut down
periods bleed air from this plug.
9
NBR FPM
Prop. section P2 S26-58473-0 S26-58473-5
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
9
Code Internal drain External drain
A A A A
Z Z
X Y X Y
11
B X B X Y
A A A A
Z Z
X Y X Y
09
B X B X Y
Features
• Direct operated check valve
• SAE61 and SAE62 flange
• 4 sizes (SAE ¾", 1", 1¼", 1½")
• 3 springs
• 5 options for body sealing
Ordering Code
C5V B
9 08
10
SAE 1"
SAE 1¼"
019 1)
M14 mounting
screws
12 SAE 1½"
Code Seals
Code Flange 1 NBR
3 SAE61 5 FPM
6 SAE62
General
Size 06 (¾") 08 (1") 10 (1¼") 12 (1½")
Mounting 2-port inline flange (SAE61 and 62)
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 0.6 0.9 1.3 1.8
Hydraulic
Max. operating pressure SAE61 [bar] 350 350 280 210
SAE62 [bar] 420 420 420 420
Nominal flow [l/min] 100 200 400 750
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
C5V06
C5V08
C5V10
C5V12
Seal kits
9
NG NBR FPM
06 S26-75409-0 S26-75409-5
08 S26-75410-0 S26-75410-5
10 S26-75411-0 S26-75411-5
12 S26-75412-0 S26-75412-5
Features
• Pilot operated check valve
• 2-port body with SAE61 flange
• 3 sizes (SAE ¾", 1", 1¼")
• 4 opening ratios
• Optional with position control
Y1 (must be connected)
X1
Ordering code
C5P 8 A
9 Pilot operated Nominal SAE61 Pilot Opening Cracking Design Seals Options
check valve size interface ports ratio pressure series
X1 and
Y1=G¼"
Code Options
omit Standard
Code Nominal size
Position control
06 ¾" 013
with protection
08 1"
10 1¼"
Code Seals
1 NBR
SAE61 5 FPM
Code Max. pressure Size
4 280 bar 10 (SAE61)
5 350 bar 06/08 (SAE61) Flow Flow
Code Size
A®B B®A
06 1.0 bar 1.5 bar
2
Code Opening ratio Code Opening ratio 1) 08/10 1.0 bar 1.7 bar
1 1:1 E 1:1 06 4.0 bar 5.5 bar
4
3 3:1 F 3:1 08/10 3.5 bar 6.0 bar
8 8:1 G 8:1 06 2.0 bar 3.0 bar
6
9 10 : 1 H 10 : 1 08/10 2.2 bar 3.8 bar
1) Position control incl. amplifier for C5P08/10 only.
C5P UK.INDD CM 09.04.15
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting 2-port inline flange (SAE61)
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 3.9 4.4 5.7
Hydraulic
Max. operating pressure Ports A, B [bar] 350 350 280
Port Y1 [bar] 30 30 30
Nominal flow [l/min] 180 360 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
177.5
67.3 40.5
US
U (V)
L signal 9
2.2
Y1
X1 Cap 0 stroke
38
PNP contact
brown +
Position Cover US
47
control Code DC
013 blue
Cable 2 m lg. 0V
-
(l) black
Body
C5P
B RL (relais)
p/Q-performance curves
C5P06
C5P08
C5P10
NG
Seal kits
NBR FPM
9
06 S26-59404-0 S26-59404-5
08 S26-59405-0 S26-59405-5
10 S26-59406-0 S26-59406-5
Dimensions
Type L1 L2 L3 L4 L5 B1 H1 H2 H3 H4 D1 D2
C5P06 22.2 95.8 119.8 137 67.3 60 37 47.6 90 128 19 10.5
C5P08 26.2 112.9 139.4 137 67.3 60 45 52.4 96 134 25 10.5
C5P10 30.2 112.9 146.9 137 67.3 75 48 58.7 109 147 32 12.5
Ports
Port size
Port Function
C5P06 C5P08 C5P10
A Inlet or outlet ¾" SAE61 1" SAE61 1¼" SAE61
B Outlet or inlet ¾" SAE61 1" SAE61 1¼" SAE61
X1 External pilot port G¼" G¼" G¼"
Y1 External pilot drain G¼" G¼" G¼"
access09.INDD CM 16.04.15
Inlet flange
Inlet flange
Port size Order no. 1)
D1 L1 L2 L3 LA LB LX LY T2
SAE61
G¾” PCFF33GSU 19 36 18 19 49 66 22.3 47.6 3/8” UNC
G1” PCFF34GSU 25 38 18 19 53 71 26.2 52.4 3/8” UNC
G1¼” PCFF35GSU 31 41 21 22 69 80 30.2 58.7 7/16” UNC
G1½” PCFF36GSU 38 44 25 24 77 94 35.7 69.9 1/2” UNC
SAE62
G¾” PCFF63GSU 19 36 19 22 53 71 23.8 50.8 3/8” UNC
G1” PCFF64GSU 25 44 24 24 69 80 27.8 57.2 7/16” UNC
G1¼” PCFF65GSU 31 44 27 25 77 94 31.8 66.6 1/2” UNC
G1½” PCFF66GSU 38 51 30 28 89 106 36.5 79.3 5/8” UNC
SAE62
G¾” PFF63GSU 19 36 19 18 53 71 23.8 50.8 10.5 3/8” x 1 1/2 UNC
G1” PFF64GSU 25 44 24 20 69 80 27,8 57,2 11.5 7/16” x 1 1/2 UNC
G1¼” PFF65GSU 31 44 27 22 77 94 31.8 66.6 15.0 1/2” x 1 3/4 UNC
G1½” PFF66GSU 38 51 30 24 89 106 36.5 79.3 17.0 5/8” x 2 1/4 UNC
access09.INDD CM 16.04.15
34.2
Ø30.5
access09.INDD CM 16.04.15
DIN / ISO ⅛ ¼
L-port
⅜
T-port
½ ¾ 1 1¼ 1½ 2
Pressure valves,
manual operation
R4V Pressure relief function • • • • • • 10-2
R4R Pressure reducing function • • • • • • 10-8
Pressure valves,
proportional operation
R4V*P2 Pressure relief function • • • • • • 10-14
R4R*P2 Pressure reducing function • • • • • • 10-19
Directional seat valves
D4S In-line mounted • • • • • • 10-24
Flow valves
MV / 9MV Throttle valve, with handle • • • • • • 10-33
N / 9N Throttle valve, with knob • • • • • • 10-35
F / 9F Throttle check valve, with knob • • • • • • • • • 10-37
PCM / 9PCM Flow control valve, with knob • • • • • 10-39
Check valves
C / 9C Direct operated • • • • • • 10-41
CP / 9CP Pilot operated • • 10-43
RH Pilot operated • • • • 10-45
Accessories
Plug-in connectors 10-48
10
content10.indd CM 18.02.15
Features
R4V10 L-body
• Pilot operated with manual adjustment
• 2 interfaces:
- L-body (R4V06-G¾", R4V10-G1¼")
- T-body (R4V03-G½", R4V06-G1")
• 3 pressure stages
• 3 adjustment modes
- Hand knob
- Acorn nut with lead seal
- Cylinder lock
• With optional vent function
R4V06 L-body
10
R4V 5 A
Pressure Nominal Max. Body Pressure Adjust- Drain Switching Solenoid Design Seal Design Options
relief valve size pressure stages ment line type voltage series
350 bar (not required
for ordering)
1) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
R4V
General
Design T-body L-body
Size 03 (½") 06 (1") 06 (¾") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 3.2 6.6 3.3 5.6
Hydraulic
Max. operating pressure [bar] Ports A and X up to 350; Ports B and Y 30 bar
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20…+70 (NBR: -25…+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
Viscosity recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
10 Viscosity permitted
Viscosity recommended
[cSt] / [mm2/s] 20...400
[cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
[V] 120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70/70 VA 70/70 VA
in rush [W] 32.7 31 31.9 28.2 280/290 VA 280/290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Dimensions
T-body
10
1) The performance curves are measured with external drain. For internal drain the tank pressure has to be added to curve.
L-body
Seal kits
NG NBR FPM
03 S26-58507-0 S26-58507-5
10 06
10
S26-58475-0
S26-58508-0
S26-58475-5
S26-58508-5
NG Body B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 H7 H8 L1 L2 L3
03 T-body 85 – – – 27.5 21 59.5 97.5 – – – – 53 92 –
06 T-body 136 – – – 38 28 93 131 – – – – 66.5 117.5 –
06 L-body – 81 76 43 – – – – 23 51 81 119 – – 49
10 L-body – 120.7 85.8 77.8 – – – – 38.1 50.8 96 134 – – 49.8
Port size
Ports Function
R4V03 T-body R4V06 L-body R4V06 T-body R4V10 L-body
A pressure (inlet) G½ " G¾ " G1 " G1¼ "
B tank (outlet) G½ " G¾ " G1 " G1¼ "
X 1) external remote control or vent connection G¼ " G¼ " G¼ " G¼ "
Y1 2) external drain G¼ " G¼ " G¼ " G¼ "
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
10
Z Z
A A
X Y X Y
11
X Y X Y1
B B
Z Z
A A
X Y X Y
09
X Y X Y1
B B
Features
• Pilot operated with manual adjustment R4R10 L-body
• Normally closed to avoid undesired motion
• 2 interfaces
- L-body (R4R06-G¾", R4R10-G1¼")
- T-body (R4R03-G½", R4R06-G1")
• 3 pressure stages
• 3 adjustment modes
- Hand knob
- Acorn nut with lead seal
- Cylinder lock
• With optional vent function
R4R06 L-body
10
R4R 5 2 B
Pressure Nominal Max. Body Pressure Adjust- Drain line Switching Solenoid Design Seal Options
reducing size pressure stages ment ext. from type voltage series
valve 350 bar pilot head
(Y1)
10
1) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
R4R
General
Design T-body L-body
Size 03 (½") 06 (1") 06 (¾") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 3.2 3.3 5.6 6.6
Hydraulic
Max. operating pressure [bar] Ports A, B and X: 350; Port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt]/[mm2/s] 20...400
Viscosity recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
10 Viscosity permitted
Viscosity recommended
[cSt] / [mm2/s] 20...400
[cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
[V] 120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
in rush [W] 32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
30
Pressure p [bar]
25
20
15
10
5
0 50 100 150
Flow Q [l/min]
30
Pressure p [bar]
25
20
15
10
5
80 10
Pressure p [bar]
70
60
50
40
30
20
10
T-body L-body
Seal kits
NG NBR FPM
10 03
06
S26-58507-0 S26-58507-5
S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
NG Body B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 L1 L2 L3
03 T-body 85 – – – 27.5 59.5 97.5 – – – 53 92 –
06 T-body 136 – – – 38 93 131 – – – 66.5 117.5 –
06 L-body – 81 76 43 – – – 51 81 119 – – 49
10 L-body – 120.7 85.8 77.8 – – – 50.8 96 134 – – 49.8
Port size
Ports Function
R4V03 T-body R4V06 L-body R4V06 T-body R4V10 L-body
B pressure (inlet) G½ " G¾ " G1 " G1¼ "
A pressure (outlet) G½ " G¾ " G1 " G1¼ "
X1 external remote control or vent connection G¼ " G¼ " G¼ " G¼ "
Y1 external drain G¼ " G¼ " G¼ " G¼ "
51.8
X1 Y1
70
15
143 max.
60.3
38.6
X1 Y1
Pilot valve
Seal kits
NBR FPM
85
AC solenoid
S26-35237-0 S26-35237-5
Main valve
10
B
X Y
11
X Y1
A
Z
B
X Y
09
X Y1
A
Features
• Continuous adjustment by proportional solenoid R4V10*P2 L-body
• 2 interfaces
- L-body (R4V06-G¾", R4V10-G1¼")
- T-body (R4V03-G½", R4V06-G1")
• 3 pressure stages
• With mechanical maximum pressure adjustment
R4V06*P2 L-body
10
Ordering code
R4V 5 P2 G0R A
Proportional Size Max. Body Pressure Adjust- Drain Proportional Solenoid Design Seal Design Options
pressure pressure stages ment line pressure voltage series
relief valve 350 bar control 12 V= 1) (not required
for ordering)
10
MTTFD value [years] 75
Weight [kg] 5.0 5.1 7.4 8.4
Hydraulic
Max. operating pressure [bar] Ports A and X up to 350; Ports B and Y 30 bar
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 20...400
Viscosity recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999), 18/16/13
Electrical (prop. solenoid)
Duty ratio [%] 100
Nominal voltage [V] 12 =
Max. current [A] 2.3
Coil resistance [Ohm] 4 at 20 °C
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Power amplifier PCD00A-400
R4VP2 UK.indd CM 18.02.15
1) The performance curves are measured with external drain. For internal drain the tank pressure has to be added to curve.
T-body
Seal kits
NG NBR FPM
03
06
S26-58507-0
S26-58475-0
S26-58507-5
S26-58475-5 10
Prop. section P2* S26-58473-0 S26-58473-5
NG Body B1 H1 H2 H3 H4 H5 L1 L2
03 T-body 85 27.5 21 59.5 144.5 106.5 53 92
06 T-body 136 38 28 93 178 140 66.5 117.5
Port size
Ports Function
R4V03*P2 T-body R4V06*P2 T-body
A pressure (inlet) G½ " G1 "
B tank (outlet) G½ " G1 "
X 1) ext. remote control or vent connection G¼ " G¼ "
Y1 2) external drain G¼ " G¼ "
* Please combine seal kit of one size with seal kit of prop. section for complete seal kit.
1) Closed when supplied.
2) Port Y1 is only available at drain line (code 2) external from the pilot head.
L-body
Seal kits
NG NBR FPM
10 06
10
S26-58475-0
S26-58508-0
S26-58475-5
S26-58508-5
Prop. section P2* S26-58473-0 S26-58473-5
NG Body B2 B3 H6 H7 H8 H9 H10 L3
06 L-body 81 76 23 51 81 166 128 49
10 L-body 120.7 85.8 38.1 50.8 96 181 143 49.8
Port size
Ports Function
R4V06 L-body R4V10 L-body
A pressure (inlet) G¾ " G1¼ "
B tank (outlet) G¾ " G1¼ "
X 1) ext. remote control or vent connection G¼ " G¼ "
Y1 2) external drain G¼ " G¼ "
* Please combine seal kit of one size with seal kit of prop. section for complete seal kit.
1) Closed when supplied.
2) Port Y1 is only available at drain line (code 2) external from the pilot head.
Features
• Continuous adjustment by proportional solenoid
R4R10*P2 L-body
• Normally closed to avoid undesired motion
• 2 interfaces
- L-body (R4R06-G¾", R4R10-G1¼")
- T-body (R4R03-G½", R4R06-G1")
• 3 pressure stages
• With mechanical maximum pressure adjustment
R4R06*P2 L-body
Ordering code
R4R 5 2 P2 G0R B
10
Pressure Nominal Max. Body Pressure Adjust- Drain Proportional Solenoid Design Seal Options
reducing size pressure stages ment line ext. pressure voltage series
valve 350 bar from pilot control 12 V=
head (Y1)
Technical data
General
Design T-body L-body
Size 03 (½") 06 (1") 06 (¾") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight [kg] 5.0 5.1 7.4 8.4
Hydraulic
Max. operating pressure [bar] Ports A, B and X up to 350; Port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999) 18/16/13
Electrical (prop. solenoid)
Duty ratio [%] 100
Nominal voltage [V] 12 =
Max. current [A] 2.3
Coil resistance [Ohm] 4 at 20 °C
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Power amplifier PCD00A-400
Command/pressure curve
10
70
60
50
40
30
20
10
1)
Measured at 350 bar primary pressure pB.
T-body
10 NG
Seal kits
NBR FPM
03 S26-58507-0 S26-58507-5
06 S26-58475-0 S26-58475-5
Prop. section P2* S26-58473-0 S26-58473-5
NG Body B1 H1 H2 H3 H4 L1 L2
03 T-body 85 27.5 59.5 144.5 106.5 53 92
06 T-body 136 38 93 178 140 66.5 117.5
Port size
Ports Function
R4V03*P2 T-body R4V06*P2 T-body
B pressure (inlet) G½ " G1 "
A pressure (outlet) G½ " G1 "
X1 1) ext. remote control or vent connection G¼ " G¼ "
Y1 external drain G¼ " G¼ "
* Please combine seal kit of one size with seal kit of prop. section for complete seal kit.
1)
Closed when supplied.
L-body
NG
Seal kits
NBR FPM
10
06 S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
Prop. section P2* S26-58473-0 S26-58473-5
NG Body B2 B3 H6 H7 H8 H9 L3
06 L-body 81 76 51 81 166 128 49
10 L-body 120.7 85.8 50.8 96 181 143 49.8
Port size
Ports Function
R4V06*P2 L-body R4V10*P2 L-body
B pressure (inlet) G¾ " G1¼ "
A pressure (outlet) G¾ " G1¼ "
X1 1) ext. remote control or vent connection G¼ " G¼ "
Y1 external drain G¼ " G¼ "
* Please combine seal kit of one size with seal kit of prop. section for complete seal kit.
1)
Closed when supplied.
Features
• Leak-free seat valve design
• 2 body designs
- L-body (2-port)
- T-body (3-port)
• Numerous pilot options
• 4 port sizes
- G ½", G 1" for T-body
- G ¾", G 1 ¼" for L-body
• 6 poppet types
D4S06 L-body
10
D4S B
Seat Nominal Body Pilot Cap Sleeve Spool Spring Switching Solenoid Design Seals Options
valve size connection version type type voltage series
10
With 0.8 dia. orifice at the bottom and VV01 code 10 and shuttle valve code DA and
03 1 BN
15° chamfer position control 2) with amplifier
2 VV01 code 12 and shuttle valve code DA and
With 1.2 dia. orifice at the bottom and
06, 10 1 BQ
15° chamfer position control 2) with amplifier
4 03, 06,10 With closed bottom and 45° chamfer 1, 3 BC VV01 code 10 and position control 2) with amplifier
A1) 06, 10 Safety spool (for position control only) 3 BE VV01 code 12 and position control 2) with amplifier
B1) 06, 10 Throttle spool, 10° chamfer 3 BA Position control 2) with amplifier
C1) 06, 10 Throttle spool, 3° chamfer 3 Position control 2) with amplifier and
BF
shuttle valve code CA
Position control 2) with amplifier and
BL
shuttle valve code DA
Technical data
General
Design T-body L-body
Size 03 (½") 06 (1") 06 (¾") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight D4S T-body [kg] 3.2 6.6 — —
D4S L-body [kg] — — 3.3 5.6
Hydraulic
Max. operating pressure [bar] Ports A, B up to 350; Port Y 140 (with VV01)
Nominal flow [l/min] 180 360 360 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
[V] 110 at 50 Hz 230 at 50 Hz
Supply voltage 12 V = 24 V = 98 V = 205 V =
[V] 120 at 60 Hz 240 at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70/70 VA 70/70 VA
in rush [W] 32.7 31 31.9 28.2 280/290 VA 280/290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
10
X-Y
X-Y
X Z Y
X Z Y
AZ
AZ
B
AA AB X1 B
X A-X AA AB
A-X A A
A
with vent valve VV01
Y1
Y1
X-Y
X-Y
X Z Y
X Z Y
VV01
VV01
AZ
AZ
B
AA AB X1 B
X A-X AA AB
A-X A A
A
D4S UK.indd CM 17.04.15
Selection of cartridges
Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet B/C
Seal kits
NG NBR FPM
03 S26-58507-0 S26-58507-5
10 06
10
S26-58475-0 S26-58475-5
S26-58508-0 S26-58508-5
Size L1 L2 B1 H1 H2 H3 H4
03 (T-body) 53 92 85 27.5 21 59.5 97.5
06 (T-body) 66.5 117.5 136 38 28 93 131
Size L3 B2 B3 B4 H5 H6 H7 H8
06 (L-body) 49 81 76 43 23 51 81 119
10 (L-body) 49.8 120.7 85.6 77.8 38.1 50.8 96 134
Port size
Ports Function
D4S03 T-body D4S06 L-body D4S06 T-body D4S10 L-body
A inlet or outlet G½" G¾" G1" G1¼"
B outlet or inlet G½" G¾" G1" G1¼"
X1 external pilot port G¼"
Y1 external drain 1) G¼"
1)
With VV01 only
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
10
70
Wire cross section [mm2] 3 x 0.5
86 without VV01
133 with VV01
Vent valve
VV01
Position Cover
47
control Code
013
Cable 2 m lg.
Body D4S
150
10
Note:
Stroke limiter not for use with D4S03, VV01, shuttle valve and positon control.
10
∆p/Q curves
∆p
All characteristic curves measured with HLP46 at 50 °C. Flow rate Q [l/min] = Kv · γ
2)
Only for size 400
Technical data
Max. pressure [bar] Flow [l/min] Max. cross.sect. Kv factor valve
Size Weight [kg]
steel brass ∆p 10 bar [cm²] ∆p 10 bar open
200 350 140 11 0.07 3.5 0.13
400 350 140 25 0.14 6.3 0.31
600 350 140 65 0.37 18.5 0.54
800 350 140 105 0.55 27.5 0.95
1200 350 – 160 0.90 45.7 1.58
1600 210 – 190 1.10 54.6 1.9
Size and needle type
200-2 7
200-3 2
400-2 11
MV-9MV UK.indd CM 18.02.15
10
Size R* H H3 H2 H1 B ØD1 L ØD SW
2 ⅛ 27 72 67 20.6 16 15 27 45 15.7
4 ¼ 36 90 85 27.7 21 20 38 51 22.1
6 ⅜ 42 111 103 34.8 26 23 45 64 25.4
8 ½ 55 134 121 42.7 32 29 53 83 31.8
12 ¾ 59 147 133 41.1 38 36 64 98 41.2
∆p
Flow rate Q [l/min] = Kv · γ
Specifications
Operating temperature -40 °C to +121 °C
Ordering code
N
Thread Needle Thread Body Needle Clamping Seal
type valve size screw
10
1200 3/4 Code Needle
1600 1 Standard 2-stage
omit
needle
Code Body Micro-fine hollow
4 1)
needle with slot
S Steel
B Brass
1)
Only for sizes 200 to 600
p/Q curves
Dimensions
Hexagon adjusting
knob, standard for
size 1600
10
Size R* Threads H3 H2 H1 B L1 L ØD SW
200 ⅛ 39 35 8 16 16 38 19 –
400 ¼ 46 40 10.5 21 25 51 21 –
600 ⅜ 55 49 13 26 32 64 25 –
800 ½ 69 61 16 32 33 67 30 –
1200 ¾ 86 71 19 38 41 83 35 –
1600 1 124 107 22.5 45 54 108 – 47.8
* G or NPTF
∆p
Flow rate Q [l/min] = Kv · γ
Specifications
Return check poppet
0.4 bar
Nominal cracking pressure
Operating temperature -40 °C to +121 °C
Ordering code
F
Thread Throttle Thread Body Needle Clamping Seal
type check size screw
valve
Code Thread Code Seal
omit NPTF omit NBR
9 BSPP V FPM
Technical data
Pressure [bar] Max. flow Throttle surface Throttle v. open Weight [kg]
Size
Steel Brass [l/min ∆p10bar] [cm²] Kv factor Steel Brass
200 350 140 11 0.066 3.3 0.13 0.13
400 350 140 25 0.13 6.3 0.23 0.23
600 350 140 40 0.22 11.2 0.31 0.31
800 350 140 50 0.28 14 0.67 0.68
1200 210 140 120 0.70 35.4 1.17 1.18
1600 210 35 250 1.48 75 2.31 2.32
2000 210 – 250 1.48 75 3.67 –
2400 210 – 250 1.48 75 4.62 –
3200 210 – 250 1.48 75 7.78 –
F-9F UK.indd CM 11.02.15
Controlled flow vs. pressure drop needle fully open Free flow vs. pressure drop needle fully open
Dimensions
Hexagon adjusting
knob, standard for
sizes 1600 to 3200
10
Size R* H3 H2 H1 B L1 L ØD SW T
200 ⅛ 39 35 8 16 36 51 19 - 9
400 ¼ 46 40 10.5 21 43 67 21 - 13
600 ⅜ 55 49 13 26 45 70 25 - 13
800 ½ 69 61 16 32 57 87 30 - 16
1200 ¾ 86 71 19 38 65 99 35 - 17
1600 1 124 107 22.5 45 83 127 - 47.8 20
2000 1¼ 130 114 29 58 99 143 - - 21.5
2400 1½ 137 120 35 70 114 143 - - 23.5
3200 2 146 130 44.5 89 134 165 - - 25
* Pipe thread G or NPTF
PCCM
Technical data
Max. Flow control Check valve
Weight
Size press. Q* ∆p Qmax ∆p [kg]
[bar] [l/min] [bar] [l/min] [bar]
400 210 1 - 10 7 20 3 0.82
600 210 2 - 25 7 30 3 1.05
800 210 6 - 60 11 75 8 1.68
1200 210 10 - 100 11 130 8 3.64
1600 210 19 - 190 11 250 10 6.59
Ordering code
PC M S
Thread Press. Design Thread Steel Clamping Seal
comp. flow Design
type size body screw series
control
valve (not required
for ordering)
Code Design
Without check
Code Clamping screw
Hexagon
10
omit valve omit socket
With check With knurled
C valve F knob
T 1) Tamper-proof
Code Size
400 1/4
600 3/8
800 1/2
1200 3/4
1600 1
Dimensions
10
Hexagon ad-
justing knob,
standard for
size 1600
Size R* H3 H2 B L1 B1 L2 ØD SW
400 ¼ 69 64 35 16 18 92 21 -
600 ⅜ 80 74 38 18 19 106 25 -
800 ½ 103 95 44 22 22 125 30 -
1200 ¾ 128 116 57 28 29 149 35 -
1600 1 175 158 70 33 35 176 - 47.8
* Pipe thread G or NPTF
PCM-9PCM UK.indd CM 18.02.15
Technical data
Size 200 400 600 800 1200 1600
steel [bar] 350 350 350 350 350 210
Max. operating pressure
brass [bar] 140 140 140 140 140 34
Pressure drop ∆p [bar] 10 10 10 10 1 1
Flow Q [l/min] 40 65 110 155 112 160
Ordering code
C
Thread
type
Pipe
mounting
Port size Body Opening
pressure 10
Code Thread Code Pressure [bar]
omit NPTF omit 0.35
9 BSPP 65 4.5
Dimensions
10
Technical data
Size 600 1200
Max. operating pressure [bar] 210 210
Max. pilot pressure [bar] 210 70
Flow Qmax at ∆p 2.7 bar [l/min] 30 95
Nominal size 3/8 3/4
Weight [kg] 4 7
Pilot ratios
Poppet 1 stage Poppet 2 stage
Surface ratio 5 : 1 (pilot Surface ratio 40 : 1 (pilot
spool-poppet surface) for spool decompression pin
quick response time with- surface) for low shock or
out decompression. oscillation performance
from decompression.
Ordering code
CP S M 10
Thread Check Port Steel Pilot Steel Seal
type valve, pilot size body ratio poppet
operated
Dimensions
10
Size A, B L3 B1 B2 H1 H L4 L7 H4 L L1 H2 H3 L6 L5 Ød W
9CP600S G3/8 53.3 50.8 25.4 38.1 76.2 25.4 76.2 10.4 120.7 10.7 9.4 66.5 9.4 111 9.1 -
9CP1200S G3/4 63.5 63.5 31.8 50.8 101.6 31.8 91.2 10.7 152.4 11.43 11.2 90.4 11.2 141.2 10.7 7.9
10
Ordering code
RH
Check valve, Flow Pre-
hydr. pilot discharging
operated
RH UK.indd CM 11.11.14
Technical data
General
Code RH 1 2 3 / 3V 4 / 4V
Pipe connections DIN ISO 228/1 A, B G¼ G⅜ G½ G¾
DIN ISO 228/1 Z G¼ G¼ G¼ G¼
Mounting Freely suspended in the pipeline
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 150
Weight [kg] 0.4 0.4 0.6 1.3
Hydraulic
Max. operating pressure [bar] 700 700 500 500
Flow approx. [l/min] 15 35 55 100
Pilot flow volume [cm³] 0.15 0.22 0.4 1
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity permitted [cSt]/[mm2/s] 20...400
recommended [cSt]/[mm2/s] 30...80
Pilot pressure pSt for pilot operation of the main valve Pilot pressure pSt for pilot operation of pre-discharging
(pB = 0 bar)
50
Pressure pST [bar]
40
RH3V
30
RH4V
20
10
RH UK.indd CM 11.11.14
Performance ∆p/Q curves (valid for flow polarity B to A and pilot operated direction A to B)
10
Port 1)
Type L a b SW
A, B Z
RH 1 G¼ G¼ 84 31.5 27 24
RH 2 G⅜ G¼ 90 32 28.5 27
RH 3 V G½ G¼ 100 36.5 31 32
RH 4 V G¾ G¼ 126 45 35.5 41
1) As per DIN 228/1, suitable for pipe connections with thread studs form B as per DIN 3852 page 2.
RH UK.indd CM 11.11.14
34.2
Ø30.5
1)
EN 175301-803 (new) corresponding with DIN 43650 (old).
10
access10.indd CM 17.04.15
D*FP, D*1FP
RE06M*W
VMY, VBY
TDA, TEA
TDP, TPQ
R5V, R5R
RE06M*T
RE*E*W
RE*E*T
DUR*L
PRPM
Amplifiers for proportional valves
PWD00 For valves w/o position transducer • 11-2
For valves with position transducer
PWDXX • • • • • • • • • 11-6
or valves in closed loop systems
For up to 2 single solenoid valves
PCD00 • • • • • • • • 11-10
w/o transducer
Electronics for command signal processing
Min/max adjustment, 6 command channels,
PZD00 • • • • • • • 11-14
6+1 ramps
Axis controller
For position, pressure and speed control
PID00 • • • • • • • 11-18
in closed loop systems
Multifunctional axis controller for basic and
Compax3F • • • 11-22
high end applications
Compax3F
Terminal strips, cables, PIOs 11-36
Accessories
Accessories
Test unit for items
EX-M05 11-40
with integrated electronics
11
Content11.indd RH 17.04.2015
Features
The described electronic unit combines all necessary
functions for the optimal operation of proportional direc-
tional control valves without position sensor (series D*FB,
D*1FB). The most important features are:
• Digital circuit design
• Four parameterizable command channels
• Constant current control
• Differential input stage
• Status output
• Four-quadrant ramp function
• Enable input for solenoid driver
• Status indicator
• Parametering by serial interface RS232C
• Connection by disconnectable terminals
• Compatible to the relevant European EMC standards
• Comfortable PC user software, free of charge:
www.parker.com/euro_hcd - see "Support", or directly
at www.parker.com/propxd.
Ordering code
PWD 00 A 400
Electronic module Universal Amplifier Design
directional control min/max adjustment series
Technical data
General
Model Module package for snap-on mounting on EN 50022 rail
Package material Polycarbonate
Inflammability class V0 acc. UL 94
Installation position unrestricted
Ambient temperature range [°C] -20...+60
Protection class IP 20 acc. EN 60529
MTTFD value [years] 150
Weight [g] 160
Electrical
Duty ratio [%] 100
Supply voltage [VDC] 18...30, ripple < 5 % eff., surge free 1)
Current consumption max. [A] 2.2
Pre-fusing [A] 2.5, medium lag
Command signal [V] +10...0...-10, ripple < 0.01 % eff., surge free, Ri = 150 kOhm
Input signal resolution [%] 0.025
Differential input voltage max. [V] 30 for terminals 5 und 6 against PE (terminal 8)
Enable signal [V] 0...4.0: Off / 9.0...30: On / Ri = 30 kOhm
Command channel signal [V] 0...4.0: Off / 9.0...30: On / Ri = 30 kOhm
Status signal [V] 0...0.5: Off / Us: On / rated max. 15 mA
Adjustment ranges
Min [%] 0...50
Max [%] 50...100
Ramp [s]
0...32.5
Zero offset [%] +100...-100
Current [A]0.8 / 1.3 / 1.8 / 2.7 / 3.5
Interface RS 232C, DSub 9p. male for null modem cable
EMC EN 50081-2, EN 50082-2
Connection Screw terminals 0.2...2.5 mm², disconnectable
Cable specification [mm²] 1.5 overall braid shield for supply voltage and solenoids (AWG16)
[mm²] 0.5 overall braid shield for sensor and signal (AWG20)
Cable length [m] 50
Block diagram
11
1) If solenoids with a nominal voltage of 24 V are connected, the supply voltage has to be raised to 29 V.
Dimensions
11
11
Ordering code
PWD XX A 40
11
Electronic Closed loop Amplifier Technology Design
module control min/max adjustment function series
proportional universal accel/decel ramps (not required
valves command input for ordering)
Code Function
0 Standard
Linearization
1
option
Technical data
General
Model Module package for snap-on mounting on EN 50022 rail
Package material Polycarbonate
Inflammability class V0 acc. UL 94
Installation position unrestricted
Ambient temperature range [°C] -20...+60
Protection class IP 20 acc. EN 60529
MTTFD value [years] 150
Weight [g] 160
Electrical
Duty ratio [%] 100
Supply voltage [VDC] 18...30, ripple < 5 % eff., surge free
Switch-on current typ. [A] 22 for 0.2 ms
Current consumption max. [A] 2.0
Pre-fusing [A] 2.5, medium lag
Command signal options [V] +10...0...-10, ripple <0.01 % eff., surge free, Ri = 100 kOhm
[mA] +20...0...-20, ripple <0.01 % eff., surge free, Ri = 200 Ohm
[mA] 4...12...20, ripple <0.01 % eff., surge free, Ri = 200 Ohm
<3.6 mA = solenoid output off,
>3.8 mA = solenoid output on (acc. NAMUR NE43)
Input signal resolution [%] 0.025
Differential input voltage max. [V] 30 for terminals 5 and 6 against PE (terminal 8)
[V] 11 for terminals 5 and 6 against 0V (terminal 2)
Sensor supply [V] 18...30 (Us), max. current <100 mA
Enable signal [V] 0...2.5: Off / 5...30: On / Ri = 100 kOhm
Status signal [V] 0...0.5: Off / Us: On / rated max. 15 mA
Monitor signal [V] +10...0...-10, rated max. 5 mA, signal resolution 0.4 %
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [s] 0...32.5
Zero offset [%] +100...-100
Current [A] 1.3 / 2.7 / 3.5
Initial current [%] 0...25
Interface RS 232C, DSub 9p. male for null modem cable
EMC EN 61000-6-2
Connection Screw terminals 0.2...2.5 mm², disconnectable
Cable specification [mm²] 1.5 overall braid shield for supply voltage and solenoids (AWG16)
[mm²] 0.5 overall braid shield for sensor and signal (AWG20)
Cable length [m] 50
Options
Technology function Code1 Software adjustable transfer function with 10 compensation points for
linearization of valve behaviour
Block diagram
11
Dimensions
11
11
Features
The described electronic unit combines all necessary
functions for the optimal operation of two proportional
pressure/flow control valves (series R*R, R*V, RE*E*W,
RE06M*W, DUR, PRPM, VBY, VMY, TDA, TEA).
The most important features are:
• Digital circuit design
• Two independent operable amplifiers
• Four parameterizable command channels
• Constant current control
• Two input stages 0...10 V
• Status output
• Two up/down ramp functions
• Enable input for solenoid driver
• Status indicator
• Parametering by serial interface RS232C
• Connection by disconnectable terminals
• Compatible to the relevant European EMC standards
• Comfortable PC user software, free of charge:
www.parker.com/euro_hcd - see "Support", or directly
at www.parker.com/propxd.
Ordering code
PCD 00 A 400
11 Electronic Without 2 Amplifiers Design
module position control min/max adjustment series
pressure/flow universal accel/decel ramps (not required
valves command inputs for ordering)
4 command channels
Technical data
General
Model Module package for snap-on mounting on EN 50022 rail
Package material Polycarbonate
Inflammability class V0 acc. UL 94
Installation position unrestricted
Ambient temperature range [°C] -20...+60
Protection class IP 20 acc. EN 60529
MTTFD value [years] 150
Weight [g] 160
Electrical
Duty ratio [%] 100
Supply voltage [VDC] 18...30, ripple < 5 % eff., surge free 1)
Current consumption max. [A] 5.0
Pre-fusing [A] 6.3, medium lag
Command signal [V] 0...+10, ripple < 0.01 % eff., surge free, Ri = 150 kOhm
Input signal resolution [%] 0.025
Differential input voltage max. [V] 30 for terminals 5 und 6 against PE (terminal 8)
Enable signal [V] 0...4.0: Off / 9.0...30: On / Ri = 30 kOhm
Command channel signal [V] 0...4.0: Off / 9.0...30: On / Ri = 30 kOhm
Status signal [V] 0...0.5: Off / Us: On / rated max. 15 mA
Adjustment ranges
Min [%] 0...50
Max [%] 50...100
Ramp [s]
0...32.5
Current [A]0.8 / 1.3 / 1.8 / 2.7 / 3.5
Interface RS 232C, DSub 9p. male for null modem cable
EMC EN 50081-2, EN 50082-2
Connection Screw terminals 0.2...2.5 mm², disconnectable
[mm²] 1.5 overall braid shield for supply voltage and solenoids (AWG16)
Cable specification
[mm²] 0.5 overall braid shield for sensor and signal (AWG20)
Cable length [m] 50
Block diagram
11
1) If solenoids with a nominal voltage of 24 V are connected, the supply voltage has to be raised to 29 V.
Dimensions
11
11
Features
• Digital circuit design
• Six parameterizable command channels with optional
additive or priority dependent signal processing
• Output stage with different signal options
• Input stage with different signal options
• Status output
• Four-quadrant ramp function
• Reference output for potentiometer supply
• Status indicator
• Parametering by serial interface RS232C
• Connection by disconnectable terminals
• Compatible to the relevant European EMC standards
• Optional technology function "linearization"
• Comfortable PC user software, free of charge:
www.parker.com/euro_hcd - see "Support", or directly
at www.parker.com/propxd.
Ordering code
PZD 00 A 40
11 Electronic
module
auxiliary
Universal 6 Command
channels
command input
Technology
function
Design
series
(not required
function accel/decel ramps for ordering)
Code Function
0 Standard
Linearization
1
option
Technical data
General
Model Module package for snap-on mounting on EN 50022 rail
Package material Polycarbonate
Inflammability class V0 acc. UL 94
Installation position unrestricted
Amb. temperature range [°C] -20...+60
Protection class IP 20 acc. EN 60529
MTTFD value [years] 150
Weight [g] 160
Electrical
Duty ratio [%] 100
Supply voltage [VDC] 18...30, ripple < 5 % eff., surge free
Current consumption max. [mA] 100
Pre-fusing [mA] 500 medium lag
Command signal options [V] +10...0...-10, ripple <0.01 % eff., surge free, Ri = 100 kOhm
[mA] +20...0...-20, ripple <0.01 % eff., surge free, Ri = 200 Ohm
[mA] 4...12...20, ripple <0.01 % eff., surge free, Ri = 200 Ohm
<3.6 mA = output signal 0 V / 0 mA / 12 mA acc. to output option
>3.8 mA = output signal on (acc. NAMUR NE43)
Input signal resolution [%] 0.025
Differential input max. [V] 30 for terminals 5 und 6 against PE (terminal 8)
Command channel signal [V] 0...1.0: Off / 5...30: On / Ri = 100 kOhm
Status signal [V] 0...0.5: Off / Us: On / rated max. 15 mA
Output signal options [V] +10...0...-10, rated max. 15 mA
[mA] +20...0...-20, Ro < 500 Ohm
[mA] 4...12...20, Ro < 500 Ohm
Output signal resolution [%] 0.025
Reference output [V] +10 / -10, 2 %, rated max. 15 mA
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Cmd channels [%] +100...-100
Ramp [s] 0...32.5
Zero offset [%] +100...-100
Interface RS 232C, DSub 9p. male for null modem cable
EMC EN 50081-2, EN 50082-2
Connection Screw terminals 0.2...2.5 mm², disconnectable
Cable specification [mm²] 0.5 overall braid shield (AWG20)
Cable length [m] 50
Options
Technology function Code1 Software adjustable transfer function with 10 compensation points for
linearization of valve behaviour
Block diagram
11
Dimensions
11
11
Features
The described electronic unit combines all necessary
functions for the optimal operation of closed loop controls.
The most important features are:
• Extended PID controls
• Speed control with position feedback
• Differential input stage with different signal options
• Output stage with different output options
• Four-quadrant ramp function
• Status indicator
• Digital circuit design
• Parametering by serial interface RS232C
• Connection by disconnectable terminals
• Compatible to the relevant European EMC standards
• Optional technology function "linearization"
• Comfortable PC user software, free of charge:
www.parker.com/euro_hcd - see "Support", or directly
at www.parker.com/propxd.
Ordering code
PID 00 A 40
11
Electronic Universal Min/Max Technology Design
module adjustment function series
closed loop accel/decel ramps (not required
control command input for ordering)
Code Function
0 Standard
Linearization
1
option
Technical data
General
Model Module package for snap-on mounting on EN 50022 rail
Package material Polycarbonate
Inflammability class V0 acc. UL 94
Installation position unrestricted
Ambient temperature range [°C] -20...+60
Protection class IP 20 acc. EN 60529
MTTFD value [years] 150
Weight [g] 160
Electrical
Duty ratio [%] 100
Supply voltage [VDC] 18...30, ripple < 5 % eff., surge free
Current consumption max. [mA] 100
Pre-fusing [mA] 500
Command signal options [V] +10...0...-10, ripple <0.01 % eff., surge free, Ri = 100 kOhm
[mA] +20...0...-20, ripple <0.01 % eff., surge free, Ri = 200 Ohm
[mA] 4...12...20, ripple <0.01 % eff., surge free, Ri = 200 Ohm
<3.6 mA = solenoid output off,
>3.8 mA = solenoid output on (acc. NAMUR NE43)
Input signal resolution [%] 0.025
Differential input voltage max. [V] 30 for terminals 5 und 6 against PE (terminal 8)
Enable signal [V] 0...1: Off / 5...30: On / Ri = 100 kOhm
Status signal [V] 0...0.5: Off / Us: On / rated max. 15 mA
Monitor signal [V] +10...0...-10, rated max. 5 mA, signal resolution 0.4 %
Output signal options [V] +10...0...-10, rated max. 15 mA
[mA] +20...0...-20, Ro < 500 Ohm
[mA] +50...0...-50, Ro < 200 Ohm
[mA] 4...12...20, Ro < 500 Ohm
Output signal resolution [%] 0.025
Potentiometer supply [V] +10...0...-10 2 %, rated max. 15 mA
Sensor supply [V] 18...30 (Us), rated max. 100 mA
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [s] 0...32.5
Zero offset [%] +100...-100
Interface RS 232C, DSub 9pole male for null modem cable
EMC EN 50081-2, EN 50082-2
Connection Screw terminals 0.2...2.5 mm², disconnectable
Cable specification [mm²] 0.5 overall braid shield (AWG20)
Cable length [m] 50
Options
Technology function Code1 Software adjustable transfer function with 10 compensation points for
linearization of valve behaviour
Block diagram
11
Dimensions
11
11
Attention:
For application support and customized software,
please contact your local Parker representative.
C3 F001 D2 F12
Function Motion control with motion profils. Suitable for position and force/pressure control
Housing / protection class closed metal housing, isolation according to VDE 0160 / IP 20
Supply voltage [VDC] 21...27, ripple <1VSS
Current requirements [A] 0,8 for the device, digital outputs 100 mA each
Supported feedback-systems • Analog 0..20 mA, 4..20 mA, ±10 V
• Start-Stop-Interface
• SSI-Interface
• EnDat2.2-Interface
• 1VSS (max. 400 kHz) Interface, 13.5 Bit / Distance coding
• TTL (RS422) (max. 5 MHz), internal post-quadrature resolution
Set point generator • Jerk-limited ramps
• Travel data in increments, mm, inches or variable by scale factor
• Specification of speed, acceleration, delay and jerk factor
• Force/pressure inputs in N, psi, etc. variable by scale factor
Monitoring functions • Power/auxiliary supply range
• Following error monitoring
• Hard- and software switches
Inputs and Outputs • 8 control inputs: 24 VDC / 10 kOhm
• 4 control outputs Active HIGH / short-circuit protected / 24 V / 100 mA
• 4 analog current input (14 Bit)
• 2 analog voltage input (14 Bit)
• 4 analog outputs (16 Bit, current or voltage) switchable in pairs
RS232 / RS485 (switchable)
RS232: • 115200 Baud
• Word length 8 bits, 1 start bit, 1 stop bit
• Hardware handshake XON, XOFF
RS485 (2 or 4-wire): • 9600, 19200, 38400, 57600 or 115200 Baud
• Word length 7/8 Bit, 1 Start-, 1 Stop bit
• Parity (switchable) even/odd
Bus systems • Profibus DP V0-V2 (I20), 12 Mbit/s, PROFIdrive-Profil Drive technology
• CANopen (CiADS402) (I21)
• DeviceNet (l22)
• PowerLink (l30)
• EtherCAT (I31)
• Profinet (I32)
CE compliance • EMC interference emission/limit values for industrial utilization according to EN61 800-3 first
environment (commercial and residential area), class A via integrated mains filter for up to 10m
cable length, otherwise with external mains filter
• EMC immunity/limit values for industrial utilization according to EN61 800-3
Insulation requirements • Protection class I according to EN 50178 (VDE 0160 part 1)
• Contact protection: according to DIN VDE 0106, part 100
• Overvoltage: Voltage class III according to HD 625 (VDE 0110-1)
• Degree of contamination 2 according to HD 625 (VDE 0110 part 1) and EN 50178 (VDE 0160 part 1)
Environmental conditions
General environmental conditions acc. • Climate (temperature / humidity / barometric pressure)
to EN 60 721-3-1 to 3-3 • Class 3K3
Permissible ambient temperature • Operation: 0 to +45 °C class 3K3
• Storage: -25 to +70 °C class 2K3
Tolerated humidity:
• Transport: -25 to +70 °C class 2K3
• Operation: <= 85 % class 2K3
11
non condensing • Storage: <= 95 % class 3K3 (relative humidity)
• Transport: <= 95 % class 2K3
Elevation of operating site: • Please inquire for greater elevations
<=1000 m above sea level for 100 % • Protection class IP20 according EN 60 529
load ratings
EMC directives and harmonised EC norms • EC low voltage directive 73/23/EEC and RL 93/68/EEC: EN 50 178, General industrial safety
norm Equipping electric power systems with electronic operating equipment
HD 625, general electrical safety. Insulation principles for electrical operating equipment EN 60
204-1, Machinery norm, partly applied
• EC-EMC directive 89/336/EEC: EN 61 800-3, EMC norm Product standard for variable speed
drives EN 50 081-2 ... 50 082-2, EN 61 000-4-2 ...61 000-4-5
UL-Certification USL according to UL508 (listed) / CNL according to C22.2 No: 142-M1987 (listed)
Certified: E-File-No: E198563
Weight [kg] 2.0
Application example
Dimensions
40
17,5
222
216
236
11
150
23
6
130 65 7,5
80 155 80
• Compax3 ServoManager
- Intuitively understandable user interface
- Wizard technology
- Online help
- Oscilloscope function
- Optimized co-ordination of complete mechatronic
systems
• Valve and Drive manager
- All technical data of Parker valves, cylinders and drives
available
- Additionally support through the Compax3F Hydrau-
lics-Manager by configuration of user defined valves ActiveX plug-in for Integration with the Office envi-
and drives. roment
Software download, free of charge: • Office and industrial environments are constantly grow-
www.compax3.com ing closer together.
Operator Panels • The use of ActiveX technology allows simple integration
Control equipment for all text and graphics applications into Office application.
in industrial environments, from two-line displays to touch-
panels using field busses:
- Profibus DP
- CANopen
- DeviceNET
- Interbus-S
For further information please refer to POP: "Parker Op-
erator Panels". Download: www.parker-eme.com/pop.
In addition to drivers for Compax3/Compax3 powerPLmC,
drivers for other PLC products can be integrated on re- 11
quest.
11
Control
a) General
• 2 control loops for each axis for combined position and
force/pressure control
x = Standard
O = Optional
* on request
11
Dynamic positioning
A new motion profile can be selected during a positioning
sequence - a smooth transition takes place.
11
Stop movement
The Stop set interrupts the current motion set
11
Function T40
• Technology functions of the T30 version fully integrated
and available
• Master position acquisition
• Mark synchronization
• Cam switching mechanism
Cam switching mechanism
• Coupling and decoupling function
• 36 cams with individual profiles
• Cam profiles
• 4 fast cams (125 µs per cam) standard: 500 µs
• Cam memory
• 32 serial cams, 16 ms/cam cycle (0.5 ms/cam)
• Cam creation with CamDesigner
• Delay-time compensated cams: Compax3 can advance
the cam to compensate for delays in switching ele-
Master position acquisition ments.
• Acquisition by incremental encoder
• Acquisition by the HEDA real-time bus
• Virtual Master:
A second axis in the IEC program can be used to program
a motion profile, which serves as a master for one or
several axes.
11
Cam profiles
• Up to 20 cam segments can be produced by:
• Virtually random cam links (forwards and backwards)
• Freely programmable event-controlled cam branches
• Scalable cam segments and complete cam profiles
11
11
Cam generation with the integrated CamEditor
• Structured text
C := A AND NOT B
• Function plan
11
Project management
Saving an entire project (source file) including symbols
and comments to make service calls easier, because
there is no need for any project data on the device itself
Professional development tool CoDeSys
• Archiving projects as ZIP files
CoDeSys is a development environment for programming
• Creating user-specific libraries that can be reused as
that saves a significant amount of time as applications
tested sections of programs
are created.
- These libraries can be protected
• One of the most powerful development environments
available, established world-wide - Examples include winders, synchronization compo-
nents etc.
• Universal programming platform for various devices
• Various user levels make it possible to lock sections of
• Visual elements
the program with passwords
• Library management for user-defined applications
• Depending on the task at hand, users can select from
• Context-sensitive help wizard among 5 IEC languages plus CFC. These languages
• Data exchange between devices from different manu- can also be mixed
facturers
• Complete online functionality
• Sophisticated technological features
• Standard function modules deposited
. . . and all this free of charge
11
11
11 1)
Length code
Length code 1 (Example: SSK01/09: Length 25 m)
Length [m] 1.0 2.5 5.0 7.5 10.0 12.5 15 20 25 30 50
Code 01 02 03 04 05 06 07 08 09 10 14
2) Length code for SSK28
Length code 2 (Example: SSK28/22: Length 3 m)
Length [m] 0.25 0.5 1.0 3.0 5.0 10.0
Code 20 21 01 22 03 05
3) Length code for SSK27
Length A: Cable or connection from POP with one Compax3 (POP - 1.Compax3), variable length according to length code1)
(Example: SSK27/01/01: Length 1.0 m)
Length B: Cable or connection from POP with more than one Compax3 (nn > 01) (1.Compax3 - 2.Compax3 - …), length between Compax
connectors is fixed to 50 cm, variable length A from POP with first Compax according to length code1)
(Example: SSK27/03/01: Length 1.0 m)
4) Colours according to DESINA
11
Ordering code
EX 00 M05 10
Test unit Design
series
Technical data
Design Lockable rugged box, polypropylene (break proof)
Supply voltage [V] 85...260, 50...60 Hz
Power consumption [VA] max. 160
Current consumption max. [A] 1.3 at 230 V
Main input fuse [A] 3.15 time lag
Required main supply fuse [A] 16
Protection class IP40
EMC EN 61000-6-2
Valve supply [V] 24 (±5 %)
Command voltage [V] 0...±10 (±1 %), 0...10, 0...±20 mA, 0...20 mA, 4...12...20 mA, 4...20 mA
Valve central connection
Diagnostic output 0...±10 V / 0...±20 mA
11 Measurement terminals
Enable signal [V] 7.5 (±10 %)
For multimeter with Ri min = 10 kOhm
Display digits 4
Display
Resolution 10 mV / 10 mA ; 1 digit
Unit site Cable inlet connector IEC320
Main cord Main site CEE 7/7 plug
Cable length [m] 2
Valve cords A - control valves B - DC valves
Unit site Connector Amphenol SV70 DIN 40040 acc. EN175301-803
Valve site Connector 6+PE acc. EN175201-804 M12x1 as per IEC61076-2-101
Cable length [m] 3
Ambient temperature [°C] 0...40
Weight [kg] 3.9
Dimensions [mm] L 305 x B 270 x H 144
Operator panel
Front
Terminal readout
ValveMaster Voltage and Current signal
Terminal Value unit
CMD
1
A B C D E F G
Test jacks
ext. CMD
Rear
Wiring configuration
Plug EN 175301-803
85 - 260 V
11
ValveMaster
Terminal Value unit
CMD
1
A B C D E F G
11
DIN / ISO 06 10 16 25 32 40 50 63 80
Subplates
SPD Subplates, BSPP threads, DC valves • • • • 12-2
A Subplates, metric threads, DC valves • • 12-7
SPP Subplates, BSPP threads, pressure valves, DIN / ISO • • • 12-8
A102 Subplates for pressure valves, styles VB and VM • 12-11
MSP Multi-station manifold, DC valves • • 12-12
Cover, sandwich and adaptor plates
Symbols 12-19
PADA Sandwich and adaptor plates • • 12-21
H06 Sandwich plates • 12-22
CS06 Sandwich and cover plates • 12-26
D51* Cover plates • • 12-28
CB Cartridge manifold block • • • • • • • 12-30
Plates for regenerative- and hybrid circuits, series D3DW, D3FB/FP, D31NW/FB/FC/FP
Intro 12-32
A10 Adaptor plates size 10 • 12-34
H10 Sandwich plates size 10 • 12-36
Accessories for manifolds and systems
BK Bolt kits 12-38
TK Tie rod kits 12-39
Pressure gauge valves
WM Pressure gauge selector valve 12-40
Pressure switches
PSB Pressure switches 12-42
SCPSD Electronic pressure switch 12-47
Pressure intensifiers
SD500 Pressure intensifiers 12-53
12
content12.INDD CM 19.02.15
Ordering code
SPD 22 B 910 P, A, B and T = G ¼
SPD 23 B 910 P, A, B and T = G ⅜
12
Ordering code
SPD 24 B 910 P, A, B and T = G ½
Ordering code
SPD 23 BA 910 P, A, B and T = G ⅜
23.5
P
P
A B B T
115
46
54.5
92
T A
50.5
55
22.9
ø11
11.5
12.4 54 20 35.5
12
102 33 11.5 79.4
G 1/2
Ordering code
SPD 34 B 920 P, A, B and T = G ½
Ordering code
P, A, B and T = G ¾
SPD 316 B 960
X and Y = G ¼
12
Ordering code
SPD 36 B 920 P, A, B and T = G ¾
Ordering code
P, A, B and T = G ¾
SPD 46 B 910
X and Y = G ¼
15.9
X
P T
8
T P X
53
62
69.8
69.8
120
ø15
A B Y
Y
B A
ø9
25.1
25.1
42 50.5 12 160
185 60
G1
P
G 1/4
Y
12
Ordering code
P, A, B and T = G 1
SPD 48 B 910
X and Y = G ¼
Ordering code
P, A, B and T = G 1
SPD 48 BA 910
X and Y = G ¼
12
Ordering code
P, A, B and T = G 1½
SPD 612 B 930
X and Y = G ½
Order. code
P, A, B and T = M18x1.5
A 064 M
as per ISO 6149
12
Order. code
P, A, B and T = M22x1.5
A 104 M
as per ISO 6149
A UK.INDD CM 02.09.13
Valve size DIN NG10, ISO 6264-06-07-*-97, DIN 24340 form D / ISO 5781-06-07-0-00
Ordering code
A, B = G ¾
SPP 3M6B 910
X, Y = G ¼
Valve size DIN NG25, ISO 6264-08-11-*-97, DIN 24340 form D / ISO 5781-08-10-0-00
12
Ordering code
A, B = G 1
SPP 6M8B 910
X, Y = G ¼
Valve size DIN NG32, ISO 6264-10-15-*-97, DIN 24340 form D / ISO 5781-10-13-0-00
Ordering code
A, B = G 1½
SPP 10M12B 910
X, Y = G ¼
12
Ordering code
P, T = G ¾
SPP 3R6B 910
X=G¼
Ordering code
P, T = G 1¼
SPP 6R10B 910
X=G¼
12
Ordering code
A, B = G 1½
SPP 10R12B 910
X=G¼
Ordering code
A, B, Y = G ¾
A102 R3/4-OD1
X=¼
12
Features
• Very low pressure drop due to large drilling parameters
• P- and T-ports on both faces
• Also available with gauge ports G¼
• Separation in P or T channel optional - please consult A B A B
P P
your distributor
T T
P A B T P A B T
PA A B PB PA A B PB
P P
T T
P A B T P A B T
Ordering code
MSP B 9
Multiple Stations Nominal Port size BSPP Port Metric Design Gauge
subplate, size Port thread location fastening series port
standard screws
Technical data
Interface DIN 24340, Form A, CETOP, ISO
Mounting position unrestricted (valve axis preferably horizontal)
Working pressure [bar] max. 350
MSP*D23 B910*
* ( ) only MSP*D23B910C
MSP*D23 BA910
12 Code
Nominal
size
Stations
L1
[mm]
L2
[mm]
L3
[mm] P, T
Port
A, B
Gauge
port
Weight
[kg]
MSP1 D23 BA910 1 70 54 58 2.0
MSP2 D23 BA910 2 120 104 108 3.5
MSP3 D23 BA910 3 170 154 158 5.0
MSP4 D23 BA910 NG06 4 220 204 208 6.6
G½ G⅜ —
MSP5 D23 BA910 CETOP 03 5 270 254 258 8.1
MSP6 D23 BA910 6 320 304 308 9.6
MSP7 D23 BA910 7 370 354 358 11.2
MSP8 D23 BA910 8 420 404 408 12.7
MSP*D23 BA910C
Code
Nominal
size
Stations
L1
[mm]
L2
[mm] P, T
Port
A, B
Gauge port
Weight
[kg] 12
MSP1 D23 BA910C 1 70 54 3.4
MSP2 D23 BA910C 2 120 104 5.8
MSP3 D23 BA910C 3 170 154 8.4
MSP4 D23 BA910C NG06 4 220 204 10.6
G½ G⅜ G¼
MSP5 D23 BA910C CETOP 03 5 270 254 13.0
MSP6 D23 BA910C 6 320 304 15.7
MSP7 D23 BA910C 7 370 354 18.2
MSP8 D23 BA910C 8 420 404 20.6
MSP*D34 B930*
* ( ) only MSP*D34B930C
MSP*D34 BA930
Code
Nominal
size
Stations
L1
[mm]
L2
[mm] P
Port
T A, B
Gauge port
Weight
[kg] 12
MSP1 D34 BA930 1 80 56 5.1
MSP2 D34 BA930 2 160 136 10.6
MSP3 D34 BA930 3 240 216 16.0
MSP4 D34 BA930 NG10 4 320 296 21.5
G¾ G1 G½ —
MSP5 D34 BA930 CETOP 05 5 400 376 26.9
MSP6 D34 BA930 6 480 456 32.5
MSP7 D34 BA930 7 560 536 37.7
MSP8 D34 BA930 8 640 616 43.4
MSP*D34 BA930C
12 Code
Nominal
size
Stations
L1
[mm]
L2
[mm] P
Port
T A, B
Gauge port
Weight
[kg]
MSP1 D34 BA930C 1 80 56 5.1
MSP2 D34 BA930C 2 160 136 10.4
MSP3 D34 BA930C 3 240 216 15.8
MSP4 D34 BA930C NG10 4 320 296 21.2
G¾ G1 G½ G¼
MSP5 D34 BA930C CETOP 05 5 400 376 26.5
MSP6 D34 BA930C 6 480 456 31.9
MSP7 D34 BA930C 7 560 536 37.2
MSP8 D34 BA930C 8 640 616 42.6
P A B T Valve side
P T H06-1044 NG06 30
G1/4 G1/4
P A B T Manifold side
P A B T Valve side
A B
H06-1039 NG06 30
G1/4 G1/4
P A B T Manifold side
P A B T Valve side
P
H06-504 NG06 30
G3/8
P A B T Manifold side
P A B T Valve side
T
H06-711 NG06 30
G3/8
P A B T Manifold side
P A B T Valve side
M
H06-1274 NG06 30
G1/4
P A B T Manifold side
P A B T Valve side
12
P A B T Manifold side
H06-1040 NG06 30
P A B T Valve side
P A B T Manifold side
symbols12.INDD CM 02.09.13
H06DO-1291 NG06 10
P A B T Manifold side
12
symbols12.INDD CM 02.09.13
Adaptor plate PADA 1007-AA-BB, CETOP 05/03, nominal size NG10 to NG06
T T
T
B A
2x M8
46
31
70
T T
A B
P
ø11
ø7
19.5
12
27.75 17 21 54
96 25
PADA1007-AA-BB
4x M6x25
CETOP 03/05 BK 408 13.2 Nm ±15 %
ISO 4762-12.9
(O-rings included in delivery)
Adaptor plate PADA 1007/A-B/B-A, CETOP 03/05, nominal size NG10 to NG06
T T
2x M8
T
31
70
T
46
ø11
A B
ø7
A B
P
19.5
12
27.75 17 21 54
96 25
Manifold side
(O-rings included in delivery)
P A B T
H06.INDD CM 08.12.14
H06-504
T T
A B B A
46
23
21
P
P P
37.5 15
30 70
H06-711
T T
A B B A
46
23
23
T
P P
37.5 15
30 70
H06.INDD CM 08.12.14
Manifold side
(O-rings included in delivery)
P A B T
A B
H06-1040
P A B T Manifold side
CETOP 03
P A B T (O-rings and O-ring plate
Valve side
included in delivery)
P A B T Manifold side
H06.INDD CM 08.12.14
T T
A B B A
45
22.5
P P
30
10 60
Manifold side
(O-rings included in delivery)
P A B T
Meter-out
Meter-out
O-ring plate
A B Meter-in
Meter-in
O-ring plate
12
T T
48
P
S
A B A B B A
24
24
P P
61.5
70 1.3 95 56.5
H06.INDD CM 08.12.14
All ports on valve side and manifold side can be equipped with orifices or plugs (1/16 NPT).
For orifice kits see "Accessories" in chapter 8.
Symbol Ordering code
CS06040N
CETOP 03
(O-rings and O-ring plate
included in delivery)
CS06082N
39
1.3
1/16” NPT
B A
31
45
P
7
12
76
All ports on manifold side can be equipped with orifices or plugs (1/16 NPT).
For orifice kits see "Accessories" in chapter 8.
Symbol Ordering code Bolt Kit Bolt dimensions Torque
CS06082N
CETOP 03 4x M5x50
BK 300 7.6 Nm ±15 %
(O-rings and O-ring plate ISO 4762-12.9
included in delivery)
All ports on manifold side can be equipped with orifices or plugs (1/16 NPT).
For orifice kits see "Accessories" in chapter 8.
Symbol Ordering code Bolt Kit Bolt dimensions Torque
CS06080N
CETOP 03 4x M5x50
BK 300 7.6 Nm ±15 %
(O-rings and O-ring plate ISO 4762-12.9
included in delivery)
12
O-ring plate
B A
48
31
Ø5.4
Ø10
P
8.5
12 7.25 40.5
55
1.3 17
25
D51.INDD CM 02.09.13
O-ring plate
B A
Ø11.1
71
46
T T
Ø7.1
12.5
89 25.6
12
D51.INDD CM 02.09.13
cartridge cover.
A
The wide range of Parker slip-in cartridge valves allows
1 + 2 plug or orifice possible.
to design solutions for all hydraulic requirements.
Features
2
• Flanges SAE61 or SAE62 respectively CETOP square X or Y X or Y
flanges 2
1
• 2 options for pilot oil supply and drain
B
• 7 sizes 1
= orifice/plug
= port
A
Ordering code
CB A 1 10 W
12 Technical data
Mounting interface ISO 7368-B*-*-2-A/B
Mounting position unrestricted
Max. operating pressure [bar] 138 to 420 (depending on pmax of flanges)
Flanges SAE61 (3000 PSI series), SAE62 (6000 PSI series) ISO 6162,
CETOP-square flange (400 bar series)
CB.INDD CM 19.02.15
E
R
A
M2
B
B H
4) 2) I R
NG16 to NG63
0
G
D
L
Q
S
M1
2
P N M2
1) 3) 5)
Orifice thread
Port 1 and 2
Weight [kg]
Ordering code A B C D E G H I K L N O P Q Port A and B 1 and 2
CB 016 A 1 34 10 W 350 105 80 105 38.5 34 38.5 45 13 13.5 75.5 10 10 85 85 1" SAE61 G1/4 M5 6
CB 016 A 1 64 10 W 420 105 80 105 38.5 34 38.5 45 13 13.5 75.5 10 10 85 85 1" SAE62 G1/4 M5 6
CB 025 A 1 35 10 W 280 125 100 125 50 43 50 55 15 17 94.5 10 10 105 105 1-¼" SAE61 G1/4 M6 11
CB 025 A 1 65 10 W 420 125 100 125 50 43 50 55 15 17 94.5 10 10 105 105 1-¼" SAE62 G1/4 M6 11
CB 032 A 1 36 10 W
CB 032 A 1 66 10 W
210
420
125
125
125
125
145
145
72.5
72.5
51
51
72.5
72.5
55
55
15
15
31.5
31.5
125
125
15
15
15
15
95
95
115
115
1-½" SAE61
1-½" SAE62
G1/4
G1/4
M6
M6
16
16
12
CB 040 A 1 38 10 W 210 145 145 170 85 65 85 70 20 35 150 15 15 115 140 2" SAE61 G3/8 M8 25
CB 040 A 1 68 10 W 420 145 145 170 85 65 85 70 20 35 150 15 15 115 140 2" SAE62 G3/8 M8 25
CB 050 A 1 310 10 W 172 155 155 190 95 70 95 70 20 37 170 15 15 125 160 2-½" SAE61 G3/8 M8 32
CB 050 A 1 68 10 W 420 155 155 190 95 70 95 70 20 37 170 15 15 125 160 2" SAE62 G3/8 M8 32
CB 063 A 1 312 10 W 138 192 192 240 120 86.5 120 86.5 20 45 220 15 15 165 210 3" SAE61 G3/8 M8 63
CB 063 A 1 70 10 W 400 192 192 240 120 86.5 120 86.5 20 45 220 15 15 162 210 3-½" PN 400 G3/8 M8 63
CB 080 A 1 80 10 W 400 270 270 270 135 120 135 120 20 35 250 15 15 240 240 4" PN 400 G3/8 M8 139
Cartridge manifold blocks are supplied with a set of plugs and orifices.
CB.INDD CM 19.02.15
D31FPR*
Features
X P A B T1 T2 Y
• To be used in combination with the above-mentioned H10-1662
(Sandwich plate)
valves. See also series D31NWR in chapter 2 and A10-1664
series D3FB, D3FP, D31FB, D31FC and D31FP in (Adaptor plate)
X P A B T Y
chapter 3
• Port T1 is used as single tank port. Port T2 is sepa-
rated from port T1 by the elimination of the tank bridge
and is used for regeneration into the A port
Hybrid function
• The circuit conception can be integrated into the
manifold block as well Example D31FBR31
a 0 b
X P A B T1 T2 Y
H10-1666L
(Sandwich plate)
A10-1665L
(Adaptor plate)
X P A B T Y
12
General
Actuation Solenoid (only A10-1665L and H10-1666L)
Size DIN NG10 / CETOP 05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position unrestricted
Ambient temperature [°C] -25...+60, -20...+60 (D*FBR), -20...+50 (D*FPR)
MTTFD value [years] 150
A10-1664 A10-1665L H10-1662 H10-1666L
Weight [kg] 11.9 14.4 2.8 4.9
Hydraulic
Max. operating pressure [bar] 350
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70), -20...+60 (NBR: -25...+60) (D*FBR*, D*FPR*, D31FCR*)
Viscosity permitted [cSt] / [mm²/s] 2.8...400 (20...400 D*FBR, D*FPR)
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
A10* H10*
Flow max. [l/min] 150 250
Regeneration B-A [l/min] see diagram
Regeneration B-T [l/min] 75 75
Electrical characteristics
Duty ratio 100 %
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage [V] 24
Tolerance supply voltage [%] ±10
Current consumption [A] 1.21
Power consumption [W] 29
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
A B A B A B
T P 12
T P T P
Energy saving A-regeneration and switchable hybrid version for NG10 valves
45
75
T
A
T1
P A
150
135
P
117
B M6 x 12
87
T2
70
48
B
33
15
35 10 28
71 33.6 70
95 110
120
75
86
X
M8 x 14
Ø9 45
Ø15
12
Symbol Ordering code Port
X P A B T1 T2 Y Valve side
A, T = G1
A10-1664
B, P = G¾
CETOP 05
X, Y = G¼
X P A B T Y
75
turnable
T
A
X
T1
P
A
P
150
135
B
117
B M6 x 12
87
T2
223
70
Y
48
33
15
35 10 28
71 33.6 70
110 110
6.5 120
75
101
M8 x 14
Ø9 45
Ø15
12
Symbol Ordering code Port
X P A B T1 T2 Y Valve side
A, T = G1
A10-1665L
B, P = G¾ NBR: SK-A10-1665
CETOP 05
X, Y = G¼
X P A B T Y
Sandwich plate H10-1662, mounting interface acc. DIN 24340-A10, CETOP 05 / NG10 for A-regeneration
P-A,
B-A
15
P-B
10
A-T
0
0 15 30 45 60 75 90 105 120 135 150
Flow [l/min]
Dimensions
12
P P
Y X
X A B Y B A
70
T1 T2 T2 T1
29
112 50
12
Sandwich plate H10-1666L, mounting interface acc. DIN 24340-A10, CETOP 05 / NG10 for hybrid function
P-B
10
0
0 15 30 45 60 75 90 105 120 135 150
Flow [l/min]
Dimensions 198
Y Y
T2
B B
125
P P
A A
T1 T
X
29
70 14
74
90
turnable
12
BK bolt kits
Socket head cap screws as per ISO 4762-12.9
Ordering Ordering
Description Description
code code
BK 399 Bolt kit M5x25 BK 527 Bolt kit M20x80
BK 375 Bolt kit M5x30 BK 534 Bolt kit M20x90
BK 443 Bolt kit M5x45 BK 386 Bolt kit M20x90 6 pcs.
BK 300 Bolt kit M5x50 BK 481 Bolt kit M20x110
BK 380 Bolt kit M5x60 2 pcs. BK 513 Bolt kit M20x120
BK 421 Bolt kit M5x65 BK 514 Bolt kit M20x150
BK 400 Bolt kit M5x70 BK 515 Bolt kit M20x160
BK 401 Bolt kit M5x75 BK 419 Bolt kit M24x120 8 pcs.
BK 402 Bolt kit M5x80 BK 516 Bolt kit M24x150 8 pcs.
BK 444 Bolt kit M5x85 BK 530 Bolt kit M24x160 8 pcs.
BK 403 Bolt kit M5x90 BK 418 Bolt kit M30x100
BK 468 Bolt kit M5x95 BK 536 Bolt kit M30x120
BK 404 Bolt kit M5x100 BK 509 Bolt kit M30x130 8 pcs.
BK 466 Bolt kit M5x100 2 pcs.
BK 420 Bolt kit M30x140 8 pcs.
BK 405 Bolt kit M5x110
BK 520 Bolt kit M30x150
BK 406 Bolt kit M5x115
BK 531 Bolt kit M30x150 8 pcs.
BK 424 Bolt kit M5x130
BK 518 Bolt kit M30x160
BK 408 Bolt kit M6x25
BK 519 Bolt kit M30x180
BK 385 Bolt kit M6x40
BK 310 Bolt kit M6x55 If no other specification is indicated, 1 bolt kit contains 4 screws.
BK 422 Bolt kit M6x75
BK 412 Bolt kit M6x90 Thread length
BK 508 Bolt kit M6x100
Threads M5 M6 M10 M12
BK 311 Bolt kit M6x105
BK 528 Bolt kit M6x110 Thread length 1.5 x Ø thread
BK 414 Bolt kit M8x40
BK 441 Bolt kit M8x50 Note
BK 533 Bolt kit M8x90
The torque for bolt kits or tie rod kits is according to valve
BK 538 Bolt kit M8x95
BK 510 Bolt kit M8x100 type/product. Consult product chapters.
BK 505 Bolt kit M10x35
BK 388 Bolt kit M10x40 Torque for plugs
BK 485 Bolt kit M10x45 (Specifications ±15 %) 1)
BK 506 Bolt kit M10x45 6 pcs.
BK 389 Bolt kit M10x50 Metric [Nm] BSPP [Nm] UNF [Nm]
BK 390 Bolt kit M10x50 6 pcs. M10 x 1 15 1/8 15 5/16 6.9
BK 320 Bolt kit M10x60 4 pcs. / M6x55 2 pcs.
M12 x 1.5 25 1/4 25 3/8 6.9
BK 484 Bolt kit M10x65
BK 539 Bolt kit M10x95 M14 x 1.5 25 3/8 40 7/16 25
BK 521 Bolt kit M10x120 4 pcs. / M6x120 2 pcs. M18 x 1.5 40 1/2 60 1/2 25
BK 494 Bolt kit M12x45 M20 x 1.5 50 3/4 90 9/16 40
BK 391 Bolt kit M12x50 M22 x 1.5 60 1 140 3/4 40
BK 486 Bolt kit M12x70 M24 x 1.5 65 1 1/4 240 7/8 60
BK 525 Bolt kit M12x75
M27 x 2 90 1 1/2 300 1 1/16 90
BK 360 Bolt kit M12x75 6 pcs.
BK 532 Bolt kit M12x90 M33 x 2 140 2 550 1 3/16 140
BK 504 Bolt kit M12x100 M42 x 2 240 1 5/16 240
12
BK 522 Bolt kit M12x140 6 pcs. M48 x 2 300 1 5/8 300
BK 460 Bolt kit M12x145 6 pcs. 1)
BK 415 Bolt kit M16x55 The tightening torques refer to counter material steel, cast iron and SG
iron by usage of impact wrenchs (with torsion bar) and impulse tools.
BK 366 Bolt kit M16x70
The plugs have to be screwed in slightly oiled in bodys respectively
BK 526 Bolt kit M16x80
blocks.
BK 511 Bolt kit M16x90
For aluminium plugs the specified torque above has to be reduced to
BK 529 Bolt kit M16x100 one third.
BK 487 Bolt kit M16x110 For aluminium blocks should be used 75 % of specified above.
BK 512 Bolt kit M16x150
BK 507 Bolt kit M18x75
BK 416 Bolt kit M20x70
BK 417 Bolt kit M20x75
access12.INDD CM 17.04.15
Ordering code
WM A
Pressure gauge Measuring Design Design
selector valve points series
(not required
for ordering)
Code Measuring
5 5 points
10 10 points
Technical data
General
Mounting position unrestricted
Ambient temperature [°C] -20...+60
Mounting panel mounted
Connections G⅛
12 Operation
Seals
by hand
Fluorocarbon
Measuring position selection by turning handle
Weight [kg] 1.8
Hydraulic
Max. operating pressure [bar] 315
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20…+70
Viscosity range, permitted [cSt]/[mm²/s] 20...400
recommended [cSt]/[mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Max. pressure in drain port Le [bar] 1.0
WM UK.INDD CM 17.04.15
WM5A*
Shifted view
WM10A*
Mounting opening
12
WM UK.INDD CM 17.04.15
Function
The spring loaded piston is hydraulically dampened. The
PSB provides a very accurate hysteresis between the
switching points (see diagram).
The required operating pressure is adjusted by the set-
screw. Unauthorised adjustments can be prevented by
the optional cylinder lock. The electric element is a micro
switch with snap-action contact. Three terminals permit
application as "On", "Off" or "Changeover" switch.
The electrical connection is made with a 3-pole plug-in
connector to EN 175301-803 with ground.
Note
For inductive DC loads a spark discharger should be used
to increase service life.
Features
• Flange or pipe mounting
• 4 pressure ranges
• Can be used as opener or closer
• Cylinder lock optional
Ordering code
PSB
12 Code Adjustment
Code
A
Seal
NBR
A Hexagon socket 1 FPM
S Knob with scale
Code Connection
Flange
F1
(front face)
Fitting
V1
(front face, tube Ø6)
Technical data
General
Symbol DIN 24340
Design Plunger type switch
Mounting PSB*F1* flange (front face)
PSB*V1 pipe mounting
Mounting position unrestricted
Ambient temperature [°C] -20 ... +60
MTTFD value [years] 150
Weight [kg] 1.0
Hydraulic
Operating pressure [bar] to 315
Actuating pressure difference see diagram
Duty cycle max. 1/s
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Filtration ISO 4406 (1999); 18/16/13
Electrical connection Plug-in connector to EN 175301-803
Insulation IP65 as per EN 60529 (with correctly mounted plug-in connector)
Contact load carrying capacity 5 A at 250 VAC; 1 A at 50 VDC; 0.2 A at 250 VDC
Plug EN 175301-803
Description Threaded cable joint Ordering code
Plug EN 175301-803, design type AF, protection class IP65 PG11 HR 21500157
Plug with LED, 12...230 V AC/DC, protection class IP65 PG11 HR 21502321
12
PSB160 PSB250
X = switching differential
Electrical connections
12
PSB*F1*
86
31
40 Z
15.5
20
5.5 52
15.5 124.5
31 159.5
20 176.7
40
31
15.5
Mounting
M5 Z pattern
31
15.5
″ 6.8
PSB*V1*
12
Technical Data
Switch code Ordering code Nominal size Function
H06PSB-994 06
Pressure switch connection to A or B or A and B:
Connections not used are closed by plug.
H10PSB-996 10
H06PSB-993 06
Pressure switch connection to P (left or right mounting
is possible). Connection not used is closed by plug.
H10PSB-995 10
Dimensions NG06
Dimensions NG10
12
• Compact
• Rugged
• Reliable
• Easy operation
• Long-term stability
• Excellent interference resistance
• Metal housing
• High protection class
• Many variants
• Rotatable
• Analogue output
• Password
• MPa, bar, psi
Everything in view
• Chamfered display
• Digital display
• Large
• Luminescent
• Display
• psi/bar/Mpa
• Actual pressure Thread
• Minimum pressure
• Internal thread
• Maximum pressure
• External thread
• Switching points
Easy to operate
• 3 large keys
• Display of units
Rugged
• Metal housing
Programming module
• Watertight
• Can be set with
• High interference resistance
ControllerWIN
• Vibration resistant
software
• Shockproof
12
Pressure range
-1...4 -1…10 -1...16 0…60 0…100 0…250 0…400 0…600
Pn (bar)
Overload pressure
10 20 40 120 200 500 800 1200
Pmax (bar)
Burst pressure
12 25 50 550 800 1200 1700 2200
Pburst (bar)
SCPSD-xxx-04-x6 SCPSD-xxx-04-x7
1 switching output; 2 switching outputs;
DIN EN 175301-803 form A (formerly DIN43650) M12x1; 4-pole
SCPSD-xxx-14-x7 SCPSD-xxx-14-x5
1 switching output; 2 switching outputs;
1 analogue output; 1 analogue output;
M12x1; 4-pole M12x1; 5-pole
High and low pressure High pressure (from 60 bar) Low pressure (up to 16 bar)
DMS/ceramic DMS Ceramic
12
SCPSD-100-04-27
Pressure range
Pressure range 100 bar
004; 010; 016; 060; 100; 160, 400; 600 bar
2 switching outputs
G ¼ BSPP internal thread
1 switching output; without analogue output SCPSD - xxx - 04 - x 6 M12 plug-in connector
DIN EN 175301-803 form A
(formerly DIN 43650) plug-in connector
SCPSD-60-14-27
2 switching outputs; without analogue output SCPSD - xxx - 04 - x 7 Pressure range 60 bar
M12x1 plug-in connector; 4-pole 1 switching output
1 analogue output
G ¼ BSPP internal thread
1 switching output; with analogue output SCPSD - xxx - 14 - x 7 M12 plug-in connector
M12x1 plug-in connector; 4-pole
Accessories
PC programming kit SCSD-PRG-KIT
Fixing clamp SCSD-S27
Reducing adaptor M22x1.5 SCA-¼-M22x1.5-ED
Reducing adaptor G ½ BSPP SCA-¼-ED-½-ED
Damping adaptor SCA-1/X-EDX-1/X-D
Flange adaptor for mechanical pressure switch SCAF-¼-40
Cable length in m
02 2 m
05 5 m
10 10 m
12 Plug-in connector
45 M12 cable socket; straight
55 M12 cable socket; 90° angled
56 DIN EN 175301-803 form A plug connector
(formerly DIN 43650)
Separate plugs
M12 cable socket; straight SCK-145
M12 cable socket; 90° angled SCK-155
DIN EN 175301-803 Form A plug connector
SCK-006
(formerly DIN 43650)
Features
mechanism switches the directional slide valve to the
• Mounting pattern NG06, DIN 24 340 Design A, CETOP, crossed switching position, and the intensifier piston
ISO pumps oil from the piston rod area into the high pressure
• Check valve attachable to bottom flange section. The process repeats itself until the pressure ratio
• High pressure up to 500 bar corresponding to the surface ratio has lead to a balance
• Volume flow formed with low pulsation of force on the intensifier piston.
• Compact design The pressure intensifier switches itself off and immedi-
ately on again when the high pressure (e.g. due to ex-
Design ternal leakage) begins to drop (pay attention to the flow
Main functional parts of the pressure intensifier: characteristic ). The switching speed of the slide valve is
piston, rocker mechanism, slide valve with lock, dependent on the operating speed of the intensifier piston.
4 check valves which separate the high pressure section
from the low pressure section, check valve in the tank port Note
to partition of the tank section from the primary pressure. • To avoid exceeding the admissible maximum pressure, a
pressure relief or pressure control valve must be fitted on
Function the primary side (pressure setting, max. 125 bar / 1 : 4,
After the high pressure section is filled with oil, (e.g. ex- max. 250 bar / 1 : 2 or max. 83 bar / 1 : 6).
tension of a clamping cylinder), the pressure intensifier • There must be no pressure peak on the primary side
begins operation: The low pressure moves the intensifier when operating in the maximum pressure range.
piston because of the surface ratio and compresses the • It is recommended to mount a 10µm filter on the pri-
oil column in the high pressure section. mary side to ensure damage-free operation.
At the end of the intensifier’s piston stroke, the rocker
Ordering code
SD 500 06 V
12
intensifier pressure cation (pressure intensifier) FPM series
500 bar ratio Interface DIN 24 340 (not required
(max. pressure) Design A, CETOP, ISO for ordering)
Intensification
Code
ratio
A 1:4
B 1:2
C 1:6
Technical data
General
Symbol DIN 24 300
Design Piston and poppet valve in body
Mounting type NG06, DIN 24 340, design A, CETOP, ISO
Ports Subplate
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 3.0 kg
Hydraulic
Max. operating pressure
Port A [bar] 500,
Port P, B, T [bar] 125 (ratio 1:4), 250 (ratio 1:2)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] +10...+70
Viscosity, permitted [cSt] / [mm2/s] 20 ... 400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow see performance curve
Intensification ratio pP : pA = 1 : 4, 1 : 2, 1 : 6
Flow volume QP : QA = 4 : 1, 2: 1, 6 : 1
Stroke volume [cm3] 3 (per double stroke)
Operating Hydraulic-mechanic automatic control
Accessories
Type Description Number
Seals
9.25 x 1.78 3
SD 500*06V
10.82 x 1.78 1
M5 x 75 ISO 4762-12.9 4
12
Surface finish
4x M5x75
BK401 9.0 Nm
ISO 4762-12.9
Flow characteristics
p [bar] 125 500
100 400
75 300
50 200
25 100
0
0 0,3 0,7 1 1,3 1,7 2 2,3 2,7 (1 : 6)
0 0,5 1 1,5 2 2,5 3 3,5 4 (1 : 4)
0 1 2 3 4 5 6 7 8 (1 : 2)
primary secondary Q [l/min]
Approximate values of the compression time for compressing a filled volume to target pressure (1 : 4)
12
Design
The check valve plate is equipped with a hydraulic, pilot
Accessories
operated check valve.
Type Description Number
Opening ratio: Main valve 2.5 : 1
Seals
Pilot ratio 10 : 1 H06SDV 9.25 x 1.78 4
M5x115 ISO 4762-12.9 4
Seals are included in delivery.
Technical data Mounting screws are not included in delivery.
General
Design Spring loaded ball seat valve
Characteristic curve
Mounting type Flange
Mounting position any
Pilot operated check valve
Ambient temp. [°C] -20...+60
Weight [kg] 1.3
Hydraulic
Operating pressure
range
Port A [bar] max. 500,
Port P, B, T [bar] max. 125 / 1:4 and 250 / 1:2
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] +10...+70
Viscosity, perm. [cSt] / [mm2/s] 20...400
recom. [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow see characteristic curve
Pilot ratio Main valve 2.5:1, pre-discharge 10:1
Opening pressure [bar] approx. 0.5 Curve measured with HLP46 at 50 °C.
Dimensions
12
Surface finish
4x M5x115
BK406 9.0 Nm
ISO 4762-12.9
Design Accessories
The check valve plate is equipped with a hydraulic, pilot Type Description Number
operated check valve. Seals
Opening ratio: Main valve 2.5 : 1 12.24 x 1.78 4
H10SDV
M5x75 ISO 4762-12.9 4
Pilot ratio 10 : 1
M6x50 ISO 4762-12.9 4
Seals are included in delivery.
Technical data Mounting screws are not included in delivery.
General
Design Spring loaded ball seat valve
Characteristic curve
Mounting type Flange
Mounting position any
Pilot operated check valve
Ambient temp. [°C] -20...+60
Weight [kg] 2.3
Hydraulic
Operating pressure range
Port A [bar] max. 500,
Port P, B, T [bar] max. 125 / 1:4 and 250 / 1:2
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] +10...+70
Viscosity, perm. [cSt] / [mm2/s] 20...400
recom. [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow see characteristic curve
Pilot ratio Main valve 2.5:1, pre-discharge 10:1
Opening pressure [bar] approx. 0.5
Curve measured with HLP46 at 50 °C.
Dimensions
12
Surface finish
4x M5x75
9.0 Nm
BK490 4x M6x50
18.0 Nm
ISO 4762-12.9
SD500 UK.INDD CM 19.02.15
12
12
12
© 2015 Parker Hannifin Corporation. All rights reserved. Catalogue HY11-3500/UK, 2.5M, 05/2015, LB