Nothing Special   »   [go: up one dir, main page]

Fire Alarm Control Panel: Product Overview

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

RE-102 / 104

Fire Alarm Control Panel

Product Overview
RE-102/104 is a right blend of affordability design, user friendly, latest technology and quality for fire alarm panels.
While implementing the latest in microprocessor technology for conventional panels ease to operate along with
clear visible indications come at an advantage for the end user. These are stand alone panels with 2 & 4 zones
versions. It has the optional facility for zone wise sounder / relay contacts.

Special Features:
?
Ravel Indian Manufacturer, International standard.
Switch Mode Power Supply.
?
Modular Construction, Serviceable.
?
Surface Mount Technology.
?
Battery polarity & deep discharge protection.
?

Features:
As per IS -2189 Standard.
?
Standby battery backup with built in charging.
?
Fire / Fault status in unambiguous colored LED indication.
?
Switch Mode Power Supply.
?
Tactile Keypad for easy panel operation.
?
System on indication.
?
Main, Standby status indication.
?
Low Battery visual warning with audible tone.
?
Relay output for actuators for Fire and Fault.
?
Lamp Test facility
?
Zone wise one man walk Test Facility.
?
Zone wise Isolation facility with loop voltage cut off.
?
Compatible to all type of Conventional Detectors.
?
Optional Zone Wise Sounder / Zone Wise Contact.
?
Electrical Specification:
Primary Power Common Relays
Type : Form C
120 - 220VAC , 50 Hz No of Relays :3
Standby Power Relay Contact Rating : 2Amps @ 30 VDC,
2Amps @ 30VAC.
24V D.C (2 Nos of 12v, 7Ah Sealed Lead acid Power Factor : 0.6
battery).
Operating Condition Initiating Device Circuits (Zone Circuit)
All zones are Class B wiring
Operating Temperature 0 - 49° C/32-120° F. Normal Operating Voltage : Nominal 24 VDC
Alarm Current : 15 - 35mA
Relative Humidity 93 ± 2% RH (non- Short Circuit Current : 42mA Maximum
condensing) at 32 ±2° C/90 ±3° F. Loop resistance : 50 ohms Maximum
End-Of-Line Resistor : 4.7K, 1/4watt
Charging Circuit Standby Current : 6.8mA
Charging Voltage 28.2V, ±0.5V (2.4mA for Detectors)
Charging Current 0.5 A (Max.).

Notification Appliance Circuits


Class B wiring
Operating Nominal Voltage: 24VDC
Current for NACs : 1Amps
End-Of-Line Resistor : 4K7, 1/4 watt

Mounting Detail:
ø19
290
30
30

Note:- All Dimensions are in MM


185
35

175

Mechanical Specification:
Dimensions : (350W X 250H X 100D)
Color : Red / White
Construction : 18 Gauge (1.22mm) CRCA sheet with powder-coated Finish
IP Rating : IP50
Cable Entry : 11xø19mm Knockout in top of the cabinet
Wiring Diagram:

Initiating Device Circuit


IDC’s are 1 to 4, Class B StyleC
End of Line - 4K7 1/4W

Ordering Information:

MODEL DESCRIPTION
RE-102-W 2 ZONE Fire Alarm Panel
RE-102-R 2 ZONE Fire Alarm Panel
RE-104-R 4 ZONE Fire Alarm Panel
RE-104-W 4 ZONE Fire Alarm Panel

Note:
R- Red Color
W-White Color

Compatible Devices:

MODELS DESCRIPTION
RE-316S-2L Photoelectric Smoke detector with base.
RE-316H-2L Heat detector with base.
RE-316SH-2L Photoelectric & Heat detector with base

India: United Kingdom:


RAVEL ELECTRONICS PVT LTD., RAVEL ELECTRONICS LTD.,
(An ISO 9001 Company) Unit 11, Chancel Industrial Estate, Newhall street,
150A, Electronics Industrial Estate, Perungudi, Chennai - 96 .India. Willenhall WV13 1NX, West Midlands, United Kingdom.
E-Mail: marketing@ravelfire.com; Web : www.ravelfire.com E-mail: info@ravelfire.co.uk ;Web: www.ravelfire.co.uk