World Class Test Equipment

2013/2014

IEC/EN 61243-3
DIN VDE 0682-401

Testing, Measuring and


Safety Instruments
BENNING World Class Test Equipment
2
The new generation of DUSPOL® voltage testers
safe voltage testing up to 1000 V
The international standard for voltage testers
IEC/EN 61243-3 (DIN VDE 0682-401):2011 increases
safety for work under voltage
Your work as an expert requires safe testing. Therefore, you The new generation of DUSPOL® voltage testers exceeds the
should not make any compromises concerning safety! demands of the standards concerning both the protection cat-
Voltage testers which are used on electrical systems of up to egory for housings (IP 65) and overvoltage protection (CAT IV
1000 V have to comply with the standard IEC/EN 61243-3 600 V). The nominal voltage range has been increased to a
(DIN VDE 0682-401):2011. The standard creates uniform minimum of 1000 V AC/DC in order to ensure safe testing of
testing and safety criteria on an international level and re- increased system voltages of industrial applications, photo-
markably which concentrates on user safety. voltaic systems and wind power plants as well as of hybrid
automotive engineering.

AC
1000 V D
1000 VC 1000 VC V C
AC/D AC/D 1200

CAT IV 600 V CAT IV 600 V CAT IV 600 V


DUSPOL analog
®
DUSPOL expert
®
DUSPOL® digital

All DUSPOL® voltage testers are equipped with a direct display


DUSPOL® voltage testers
system without loading the test point. In case of need, a load
circuit can be connected via a push-button which suppresses The original!
inductive and capacitive reactive voltages. Thus, it is possible Product safety at the highest level:
to clearly distinguish between high-energy and low-energy • safe voltage testing up to 1000 V AC/DC
electric circuits. • direct display without actuating a push-button
(high-impedance testing)
A vibrating motor can be activated additionally. The vibrating
• load connection via push-button
power of this motor increases proportionally to the applied volt-
Stand-by case
(low-impedance testing)
age. This is an additional indication of voltage being applied.
010911 • battery-independent voltage indication
(see page 18)
from 50 V AC/DC on
®
The DUSPOL voltage testers underlines once again the
BENNING expertise in the field of testing, measuring and • vibration alert in the test handle
safety technology. With a DUSPOL® voltage tester you ac- • robust round housing with rubberized gripping
quire an innovative product which has been tested and ap- surface for outdoor use (protection category IP 65)
proved by the independent VDE Test and Certification • tested and approved in compliance with the current
Institute. DIN EN 61243-3 (VDE 0682-401):2011 standard
BENNING World Class Test Equipment
3
DUSPOL® voltage testers – the testers with the VDE mark of conformity
safe, reliable and powerful
The new generation of DUSPOL® voltage testers
• safe voltage testing up to 1000 V AC/DC Additionally for DUSPOL® digital:
• load connection with vibration alert • voltage testing up to 1000 V AC TRUE RMS/1200 V DC
• intentional tripping of a 30 mA RCD • TRUE RMS measuring method
• phase sequence test in a three-phase mains • low-volt range: 1.0 V to 11.9 V
• single-pole external conductor test (phase) • frequency indication up to 1000 Hz
• resistance measurement up to 300 kΩ
Additionally for DUSPOL® expert, DUSPOL® digital:
• conducting-state voltage measurement of diodes
• acoustic continuity test with loud test buzzer and visual
• automatic LC display illumination by means of a light sensor
indication by means of yellow LED
• measuring point illumination by means of white
high-power LED
phase-sequence test
• phase sequence test by means of green LED (left/right) (counter-clockwise/clockwise)
• detector for non-contact localization of cable breaks on
exposed and live lines single-pole phase test:
“R” symbol for AC voltage

measuring point
illumination

acoustic and optical


continuity test

frequency indication

voltage indication
1 – 1000 V AC TRUE RMS
1 – 1200 V DC
resistance measurement and
diode test with conducting-
state voltage indication
LC display with
background lighting

sensor of non-contact
cable break detector

CAT IV
load connection
via push buttons

600 V vibrating alert


in the test handle
tested and housing with
approved protection against
dust and water jets

IEC/EN 61243-3
(DIN VDE 0682-401)
:2011 standard

Voltage and Continuity Tester


DUSPOL® analog DUSPOL® expert DUSPOL® digital PROFIPOL®
indication plunger system (illuminated)/LED LED LED/LCD (illuminated) LED
indication steps 12 – 1000 V AC/DC 12 – 1000 V AC/DC 1.0 – 1000 V AC/1200 V DC 6 – 400 V AC/DC
frequency range – – 1 – 1000 Hz –
acoustic and visual buzzer + yellow LED buzzer + yellow LED
– –
continuity test 0 – 100 kΩ 0 – 100 kΩ
diode test conducting-state/
– 0.3 – 2.0 V –
non-conducting direction
resistance measuring range – – 0.1 kΩ – 300 kΩ –
phase-sequence test LCD (“R” symbol) green LEDs (right/left) green LEDs (right/left) –
single-pole outer conductor test LCD (“R” symbol) red “lightning” LED red “lightning” LED –
polarity test LED (+/-) LED (+/-) LCD (+/-) LED (+/-)
cable break detector – yellow LED (flashing) yellow LED (flashing) –
load connection IS = 600 mA (1000 V) IS = 550 mA (1000 V) IS = 550 mA (1000 V)

via push button 30 mA RCD trip 30 mA RCD trip 30 mA RCD trip
vibrating alarm yes yes yes –
measuring point illumination – white LED white LED –
protection class IP 65 IP 65 IP 65 IP 65
item no. 050261 050262 050263 020022 PROFIPOL®
BENNING World Class Test Equipment
4
Digital Multimeter BENNING MM P3, MM 1-1 – MM 1-3, MM 1 – MM 4
reliable and precise in each and every situation
BENNING MM P3 BENNING MM 1-1, MM 1-2 and MM 1-3
Pocket-Size Digital Multimeter Digital Multimeters with Volt Sensor Function
• top-class functionality and design • the integrated Volt sensor signalises phase voltages by
• even smaller and narrower with lower weight (only 130 g) means of an acoustic signal and a red LED signal
• minimum dimensions: 132 x 86 x 19 mm • it localizes cable breaks and defective lamps in exposed
• for all-purpose use with leather case and measuring leads cables (cable reel, light chains) via the feeding side of the
phase

volt sensor
volt sensor volt sensor

MM P3

MM 1-3
MM 1-1 MM 1-2

BENNING MM 1, MM 2, MM 3 and MM 4
Digital Multimeter
Technology that inspires, Quality that convinces
• basic measuring for current, voltage, resistance, continuity,
diode, capacity and frequency
• automatic and/or manual measuring range selection
• safe current measuring up to 300 A AC via attachable cur-
MM 1 rent clamp adapter (MM 4)

MM 2 MM 3

Digital Multimeter
BENNING BENNING BENNING BENNING BENNING BENNING BENNING
MM P3 MM 1-1 MM 1-2 MM 1-3 MM 1 MM 2 MM 3
indicating range 5000 2000 2000 2000 3200 2000 2000
basic accuracy 0.6 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 %
AC voltage 0.1 mV – 600 V 0.1 mV – 750 V 0.1 mV – 750 V 0.1 mV – 750 V 1 mV – 600 V 0.1 mV – 750 V 0.1 mV – 600 V
DC voltage 0.1 mV – 600 V 0.1 mV – 1000 V 0.1 mV – 1000 V 0.1 mV – 1000 V 0.1 mV – 600 V 0.1 mV – 1000 V 0.1 mV – 600 V
AC current – – 1 mA – 10 A 1 mA – 10 A – 0.1 µA – 20 A 0.1 µA – 20 A
DC current – – 1 mA – 10 A 1 mA – 10 A 0.1 µA – 3.2 mA 0.1 µA – 20 A 0.1 µA – 20 A
resistance 0.1 Ω – 40 MΩ 0.1 Ω – 20 MΩ 0.1 Ω – 20 MΩ 0.1 Ω – 20 MΩ 0.1 Ω – 32 MΩ 0.1 Ω – 20 MΩ 0.1 Ω – 20 MΩ
continuity/diode yes/yes yes/yes yes/yes yes/yes yes/yes yes/yes yes/yes
frequency 1 mHz – 5 MHz – 1 Hz – 20 MHz 1 Hz – 20 MHz – – 1 Hz – 200 kHz
capacity 10 pF – 100 µF – 1 pF – 2 mF 1 pF – 2 mF – – 1 pF – 200 µF
temperature – – – -20 °C up to +800 °C – – –
volt sensor – yes yes yes – – –
interface – – – – – – –
software – – – – – – –
memory HOLD HOLD HOLD, MAX/MIN HOLD, MAX/MIN HOLD – –
Data Log function – – – – – – –
measuring method RMS RMS RMS RMS RMS RMS RMS
measuring category CAT III 300 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 300 V
MM 4
item no. 044084 044081 044082 044083 044027 044028 044029
BENNING World Class Test Equipment
5
Digital Multimeter BENNING 7-1 – MM 11
safety and functional diversity without any compromises
BENNING MM 7-1 BENNING MM 9, MM 10
Digital Multimeter offering highest safety Digital Multimeter of the highest measuring
for industrial applications category CAT IV
• TRUE RMS measuring method for precise measuring • highest measuring category CAT IV 600 V allows measure-
results even for non-sinusoidal signal characteristics ments direct at the source of the low-voltage installation
• highest measuring category CAT IV 600 V for highest safety • precise due to TRUE RMS measuring method
• AutoV function for automatic AC/DC voltage detection and • transmitting measuring results via optical USB interface
low input impedance (LoZ) to suppress capacitively/induc- • delivery including software BENNING PC-Win MM 10
tively induced voltages
• integrated Volt sensor for non-contact signalling of phase
voltages and cable breaks in lines USB
• LC display with bargraph indication and background lighting

volt sensor

USB

CAT IV 600 V CAT IV 600 V


TRUE RMS TRUE RMS
MM 9 MM 10

BENNING MM 11
Precision Digital Multimeter
with extraordinary features of performance
• highest measuring accuracy of 0.06 % due to TRUE RMS
measuring method and 20000 digit resolution
• an ideal measuring device for recording of measuring processes
• large memory capacity of 1000 storage locations and TRUE RMS
40000 storage locations for Data Log functions MM 11
CAT IV 600 V
• transmitting measuring results via optical USB interface
TRUE RMS • delivery including software BENNING PC-Win MM 11
MM 7-1

Digital Multimeter BENNING PC-Win MM 10/MM 11


BENNING BENNING BENNING BENNING BENNING Software for logging and analysis
MM 4 MM 7-1 MM 9 MM 10 MM 11 • software for reading and logging of measurement series
indicating range 4200 6000 6000 6000 20000 • visualisation of measurement series via line diagram and table
basic accuracy 0.5 % 0.08 % 0.5 % 0.5 % 0.06 %
AC voltage 1 mV – 600 V 10 µV – 1000 V 0.1 mV – 750 V 0.1 mV – 750 V 1 µV – 750 V
• scanning rate variable from 0.5 sec. up to 10 min.
DC voltage 1 mV – 600 V 10 µV – 1000 V 0.1 mV – 1000 V 0.1 mV – 1000 V 1 µV – 1000 V • storage of measurement series as text file
AC current 0.1 A – 300 A 10 µA – 10 A 1 mA – 10 A 1 mA – 10 A 1 µA – 10 A
DC current – 10 µA – 10 A 0.1 µA – 10 A 0.1 µA – 10 A 1 µA – 10 A
resistance 0.1 Ω – 42 MΩ 0.1 Ω – 40 MΩ 0.1 Ω – 60 MΩ 0.1 Ω – 60 MΩ 10 mΩ – 2 GΩ
continuity/diode yes/yes yes/yes yes/yes yes/yes yes/yes
frequency – 0.01 Hz – 100 kHz 1 Hz – 60 MHz 1 Hz – 60 MHz 0.01 Hz – 1 MHz
capacity – 1 nF – 10 mF 1 pF – 6 mF 1 pF – 6 mF 1 pF – 40 mF
temperature – -40 °C up to +400 °C – – -200 °C up to +1200 °C
volt sensor – yes – – –
interface – – – USB USB
Software PC-Win MM 10/MM 11
software – – – PC–Win MM 10 PC–Win MM 11
memory HOLD HOLD, MAX/MIN HOLD, MAX/MIN HOLD, MAX/MIN 1000 memory locations
Data Log function – – – – 40000 memory locations
measuring method RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS
measuring category CAT III 300 V CAT IV 600 V CAT IV 600 V CAT IV 600 V CAT III 600 V All Digital Multimeters
item no. 044073 044085 044078 044079 044080 including protective case,
safety leads and battery set.
BENNING World Class Test Equipment
6
Digital Current Clamp Multimeter
BENNING CM 1-1 – CM 1-3, CM 2, CM 3, CC 1 – CC 3
BENNING CM 1-1, CM 1-2 and CM 1-3 BENNING CM 2 and CM 3
Digital Current Clamp Multimeter for AC current Digital Current Clamp Multimeter for
Innovative technology, practical design AC/DC current
• safe current measuring up to 400 A AC • safe and non-contact measuring of high currents
• measuring inputs for voltage, resistance, continuity and • DC and AC current measuring up to 600 A AC/DC
diode test • measurement of low currents (automotive, photovoltaics,
• integrated volt sensor signalises phase voltages by means industry) (CM 2)
of an acoustic signal and a red LED signal (CM 1-3) • measuring inputs for voltage, resistance and continuity
• it localizes cable breaks and defective lamps in exposed test (CM 2)
cables (cable reel, light chains) via the feeding side of the • precise due to TRUE RMS measuring method (CM 2)
phase (CM 1-3)

volt sensor

Our !
er
best sell

TRUE RMS CM 3
CM 1-2
CAT IV 600 V CM 2
CM 1-1
CM 1-3
BENNING CC 1, CC 2 and CC 3
AC and AC/DC current clamp adapters
• safe AC current measuring up to 200 A/400 A
• connection via 4 mm safety measuring leads

output: 1 mV AC per output: 1 mA AC per output: 1 mV/10 mV AC/DC


1 A AC 1 A AC per 1 A AC/DC

suitable for BENNING ... suitable for BENNING ... suitable for BENNING ...
MM 1-1/1-2/1-3, IT 120 B, MM 1-2/1-3, PV 1-1, MM 1-1/1-2/1-3,
MM 2/3/7-1/9/10/11 MM 2/3/7-1/9/10/11 MM 2/3/7-1/9/10/11
CC 1 CC 2 CC 3

Digital Current Clamp Multimeter/Current Clamp Adapter


BENNING BENNING BENNING BENNING BENNING BENNING BENNING BENNING
CC 1 CC 2 CC 3 CM 1-1 CM 1-2 CM 1-3 CM 2 CM 3
indicating range – – – 2000 2000 2000 4000 2000
basic accuracy 1.9 % 1%–3% 1%–2% 2% 1% 1% 0.5 % 1.9 %
AC voltage – – – – 0.1 V – 600 V 0.1 V – 750 V 1 mV – 600 V –
DC voltage – – – – 0.1 V – 600 V 0.1 V – 1000 V 0.1 mV – 600 V –
AC current 1 A – 400 A 0.5 A – 200 A 0.2 A – 300 A 10 mA – 400 A 0.1 A – 400 A 0.1 A – 200 A 100 mA – 300 A 0.1 A – 600 A
DC current – – 0.2 A – 300 A – – – 10 mA – 300 A 0.1 A – 600 A
resistance – – – – 0.1 Ω – 20 MΩ 0.1 Ω – 20 MΩ 0.1 Ω – 40 MΩ –
continuity/diode –/– –/– –/– –/– yes/– yes/yes yes/– –/–
frequency – – – – – – – –
effective power – – – – – – – –
power factor (cos φ) – – – – – – – –
temperature – – – – – – –
volt sensor – – – – – yes – –
memory – – – HOLD, MAX HOLD HOLD HOLD, MAX HOLD
measuring method – – – RMS RMS RMS TRUE RMS RMS
max. clamp opening 30 mm 21 mm 25 mm 30 mm 30 mm 16 mm 25 mm 38 mm
measuring category CAT III 300 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V CAT III 300 V CAT III 300 V
item no. 044037 044110 044038 044061 044062 044063 044035 044031
BENNING World Class Test Equipment
7
Digital Current Clamp Multimeter
BENNING CM 4 – CM 9
BENNING CM 4, CM 6, CM 7 BENNING CM 8
Digital Current Clamp Multimeter of the highest Power Current-Clamp Multimeter
measuring category Power analysis for single-phase and
• precise due to TRUE RMS measuring method three-phase mains
• safe current measuring up to 1000 A AC/DC • TRUE-RMS measurements up to 1000 V, 600 A AC/DC
• highest measuring category CAT IV 600 V offering optimum • effective power measurements up to 600 kW
safety • calculation of the power factor cos φ
• indication of the load type (inductive, capacitive)
EST- • bipolar phase sequence test in three-phase mains
AUTOTtion • measuring inputs for voltage, resistance, continuity, diode,
func
frequency and temperature
• measurement of inrush currents (motors etc.)

BENNING CM 9
TRUE RMS Leakage Current Clamp with a Resolution of 1 µA
The alternative solution for insulation measurements
• measurement of leakage currents and differential currents
in electrical systems (VDE 0100) and devices (VDE 0701- TRUE RMS
0702, BGV A3, BetrSichV ( = German Health and Safety at CM 8
Work Regulations)) (CM 4 fig. similar)
• highest resolution of 1 µA in the 6 mA measuring range
• measurement without switch-off during normal operation
of the system/device, the perfect solution for preventive
maintenance
• precise and reproducible measuring results up to 100 A
• optimum screening against external magnetic fields

Differential current measurement method with BENNING CM 9


CAT IV 600 V CAT IV 600 V
TRUE RMS TRUE RMS
CM 5-1 CM 7
(CM 6 fig. similar)

BENNING CM 5-1 ✔ ✔
Digital Current-Clamp Multimeter L
0 mA
FI/RCD
0 mA

0 mA
N
• automatic selection of the correct measuring function for TRUE PE
RMS voltage/current (AC/DC), resistance, continuity and diode test ✘
25 mA

0 mA

25 mA
• safe and easy operation – measuring errors due to incorrect
measuring range selection are excluded
• short response time due to 5 scanning values per second
• voltage measurement with low input impedance (LoZ) to ✘
25 mA
suppress capacitively/inductively induced voltages

Digital Current Clamp Multimeter


BENNING BENNING BENNING BENNING BENNING BENNING Leakage
CM 4 CM 5-1 CM 6 CM 7 CM 8 CM 9 TRUE RMS
indicating range 4000 9999 4000 4000 6000 6000
CM 9
basic accuracy 0.7 % 0.9 % 0.7 % 0.7 % 0.7 % 1%
AC voltage 0.1 V – 600 V 1.3 V – 750 V 0.1 V – 750 V 0.1 V – 750 V 10 mV – 1000 V –
DC voltage 0.1 V – 600 V 0.7 V – 1000 V 0.1 V – 1000 V 0.1 V – 1000 V 10 mV – 1000 V –
AC current 0.1 A – 600 A 0.9 A – 600 A 0.1 A – 1000 A 0.1 A – 1000 A 0.1 A – 600 A 1 µA – 100 A
DC current – 0.9 A – 600 A – 0.1 A – 1000 A 0.1 A – 600 A –
resistance 0.1 Ω – 400 Ω 1 Ω – 10 kΩ 0.1 Ω – 400 Ω 0.1 Ω – 400 Ω 0.1 Ω – 20 kΩ –
continuity/diode yes/– yes/yes yes/– yes/– yes/yes –/–
frequency 1 Hz – 400 Hz – 1 Hz – 400 Hz 1 Hz – 400 Hz 0.1 Hz – 4 kHz –
effective power – – – – 1 W – 600 kW –
power factor (cos φ) – – – – ± 0.00 – 1.00 –
temperature – – – – -50 °C up to +1000 °C –
volt sensor – – – – – –
memory HOLD, MAX/MIN HOLD, MAX/MIN HOLD, MAX/MIN HOLD, MAX/MIN
HOLD HOLD, PEAK
PEAK PEAK PEAK, ZERO PEAK, INRUSH
measuring method RMS TRUE RMS RMS TRUE RMS TRUE RMS TRUE RMS
max. clamp opening 37 mm 35 mm 53 mm 53 mm 40 mm 40 mm
measuring category CAT III 600 V CAT IV 600 V CAT IV 600 V CAT IV 600 V CAT III 600 V CAT III 300 V
item no. 044056 044066 044058 044059 044064 044065

differential current measurement method


BENNING World Class Test Equipment
8
BENNING ST 710 Appliance Tester (VDE 0701-0702)
mobile and network-independent testing of electrical appliances
BENNING ST 710 Features BENNING ST 710
Battery-operated Appliance Tester for • automatic testing procedure for devices of class I (key 1),
mobile testing of electrical devices class II/III (key 2) and line test (key 3)
• testing in compliance with DIN VDE 0701-0702 (EN 62638), • testing of cable reels, multiple distributors and device
BGV A3, BetrSichV (German Health and Safety at Work connecting cables with rubber connector
Regulations), ÖVE/ÖNORM E 8701, NEN 3140 • measuring result with “pass/fail” information
• easy - operation by means of three keys • limiting values preset in compliance with DIN VDE standard
• quick - complete testing within 10 seconds • indication of correct function key in case of incorrect oper-
• mobile - testing can be made network-independently ation and if the test sample is not switched on
• sufficient battery capacity (6 x 1.5 V, mignon, AA, IEC LR6)
Application for > 2500 test samples
Safety-related testing of electrical devices/work equipment • three-phase test objects can be tested by means of
such as e.g. electrical devices/tools with ON/OFF switch, optional measuring adapter
motorized equipment, lamps, cable reels, multiple distributors
and household appliances. The protective conductor current/ Measuring functions
contact current is measured by means of the alternative • protective conductor resistance with a testing current of
leakage current measurement method. 200 mA DC and automatic polarity reversal
• insulating resistance with a testing voltage of 500 V DC
• protective conductor current and contact current by means
of alternative leakage current measurement method
• voltage measurement on external shock-proof socket (L-N,
L-PE, N-PE)
TRUE RMS

cates for are


test certifi
Forms for f electrical devices”
“Testing o r download free of
available fowww.benning.de!
charge at

Shock-proof socket onto 16 A/32 A CEE coupling onto Leakage


shock-proof plug for CM 9 CEE plug, 5-pin, for CM 9
CM 9

Differential current measurement method with BENNING CM 9

Test badges
operating conditions)
(test sample under

indication= ID IPE

ID = IPE + IL
IL Leakage current e.g. via
the water conduits and
ST 710 capacity of the washing
©

050309: with socket of type E (B/F/CZ/SK/PL) machine to earth


050315: with socket of type CH (CH)

BENNING ST 710 Optional accessories for


Battery-operated Appliance Tester BENNING ST 710/ST 720/ST 750 A
BENNING test badges “next test” (300 pieces)
ST 710 item no. 756212
indication graphic display measuring adapters for three-phase loads (passive)
protective conductor resistance 0.05 Ω – 20 Ω (see page 9) item no. 044122/044123
insulation resistance leakage Current Clamp BENNING CM 9 for the measurement of
0.1 MΩ – 20 MΩ differential current, protective conductor current and load current of
(500 V DC)
protective conductor current/ single-phase and three-phase loads
contact current by means of (see page 7) item no. 044065
0.1 mA – 20 mA measuring adapters for leakage current clamp BENNING CM 9
alternative leakage current
measurement method single-phase, conductors led through individually and with double insulation
line test RPE, RISO, short–circuit test and continuity test of shock-proof socket/shock-proof plug item no. 044131
phase conductor (L) and neutral conductor (N) three-phase, conductors led through individually and with double insulation
voltage 50 V – 270 V 16 A CEE coupling-CEE plug, 5–pin item no. 044127
scope of delivery carrying case, test cable with alligator 32 A CEE coupling-CEE plug, 5–pin item no. 044128
See page 18 + 19 for further accessories
Scope of delivery BENNING ST 710 clip, appliance cable, battery set
item no. 050308
BENNING World Class Test Equipment
9
BENNING ST 720 Appliance Tester (VDE 0701-0702)
testing of electrical appliances under operating conditions
BENNING ST 720 Measuring functions
Mains-operated and battery-operated Appliance • protective conductor resistance with a testing current of
Tester for mobile testing of electrical devices 200 mA DC and automatic polarity reversal
• testing in compliance with DIN VDE 0701-0702 (EN 62638), • insulating resistance with a testing voltage of 250 V/500 V DC
BGV A3, BetrSichV (German Health and Safety at Work Re- • mains operating mode: protective conductor current/contact
gulations), ÖVE/ÖNORM E 8701, NEN 3140 current by means of differential current/direct measurement
• quick – testing within a few seconds method with automatic mains pole reversal
• all-in-one – appliance tester and RCD tester in one single device • battery operating mode: protective conductor current/contact cur-
• unique – testing of single-phase and three-phase devices rent by means of alternative leakage current measurement method
under operating conditions • tripping time measurement of RCDs with 30 mA
• voltage measurement on external shock-proof socket
Application (L-N, L-PE, N-PE)
Testing of devices with mains voltage-dependent swit- • active testing of three-phase devices under operating con-
ching elements/mains-supply units/relays such as con- ditions by means of optional measuring adapters (item no.
trolled devices/tools, devices of information and communica- 044140/044141)
tion technology as well as of devices which can be tested
nt
completely with mains voltage only.
• differe
ntial curreethod
In mains operating mode, the protective conductor en t m
measurem CDs with 30 mA
current/contact current is measured by means of the required of R se loads
• testing of three-pha 50 V
differential current/direct measurement method.
e te s ti ng 2
• activ ge of
• ISO te
sting volta
Features BENNING ST 720
• mains operating mode for tests under operating conditions
• battery operating mode for mobile testing
• automatic testing procedure for devices of class I (key 1),
class II/III (key 2) and line test (key 1)
• reduction of the ISO testing voltage to 250 V/ 500 V for
devices with overvoltage arresters/electronic devices 16 A/32 A CEE 5-pin, active,
• testing of RCDs with 30 mA for ST 720
• measuring result with “pass/fail” information
• limiting values preset in compliance with DIN VDE standard
• indication of correct function key in case of incorrect ope-
ration, overload and if the test sample is not switched on
16 A/32 A CEE coupling, 5-pin onto shock-proof
• sufficient battery capacity (6 x 1.5 V, mignon, AA, IEC LR6) plug (passive) for ST 710/ST 720/ST 750 A
for > 2500 test samples

16 A/32 A CEE coupling, 3-pin onto shock-proof


BENNING ST 720 plug for ST 710/ST 720/ST 750 A
Mains-operated and battery-operated Appliance Tester
BENNING Shock-proof 4 mm plug for
ST 720 devices without shock-proof
indication graphic display plug for ST 710/ST 720
protective conductor resistance 0.05 Ω – 20 Ω ST 720
insulation resistance 050313: with socket of type E (B/F/CZ/SK/PL)
0.1 MΩ – 20 MΩ
(250 V/500 V DC)
protective conductor current/
contact current by means of
Optional accessories for
- differential current
BENNING ST 720
0.25 mA – 20 mA measuring adapters for three-phase loads (active)
measurement method
- alternative leakage current for measuring RPE, and IPE under operating conditions
0.25 mA – 20 mA
measurement method 16 A CEE 5-pin active item no. 044140
- direct measurement method 0.1 mA – 2 mA 32 A CEE 5-pin active item no. 044141
line test RPE, RISO, short-circuit test and continuity test of
phase conductor (L) and neutral conductor (N) BENNING ST 710/ST 720/ST 750 A
testing current of RCD 30 mA measuring adapters for three-phase loads (passive)
tripping time 10 ms – 500 ms for measurement of RPE, RISO and IEA
protective conductor current of 16 A CEE coupling, 5-pin - shock-proof plug item no. 044122
three-phase test objects under 0.25 mA – 10 mA 32 A CEE coupling, 5-pin - shock-proof plug item no. 044123
operating conditions (optional) measuring adapters for single-phase loads
voltage 50 V – 270 V for measurement of RPE, RISO and IEA
scope of delivery carrying case, test cable with 16 A CEE coupling, 3-pin - shock-proof plug item no. 044143
alligator clip, mains connection cable, 32 A CEE coupling, 3-pin - shock-proof plug item no. 044144
appliance cable, battery set shock-proof 4 mm plug for devices without Scope of delivery BENNING ST 720
item no. 050312 shock-proof plug item no. 044142
See page 18 + 19 for further accessories
BENNING World Class Test Equipment
10
BENNING ST 750 A Appliance Tester (VDE 0701-0702, VDE 0751)
testing of electrical appliances and medical electrical devices
BENNING ST 750 A
AddIn for Mebedo
test software Appliance Tester for testing electrical appliances
ELEKTROmanager and medical electrical devices
and fundamed • testing according to
- DIN VDE 0701-0702 (EN 62638): testing of electrical appliances/equipment
ted
- DIN VDE 0751-1 (EN 62353): testing of medical electrical
tte r y-operain case
devices, such as hospital bed
Ba terface ge
user in tation chan
- German Health and Safety at Work Regulation s r e
• innovative - indication and operation via colour LCD touchscreen
of test power failu
and
• powerful - 2 GB memory card for more than 100000 tests
• all in one - one appliance tester for all VDE tests

Features
• automatic and auto-configurable testing procedures
• complete test sample/customer database can be stored on SD
card and thus is directly available at the place of inspection
• management of large test sample inventories with more
than 100000 storable device tests per 2 GB SD card
• direct entry via touchscreen and external keyboard/mouse
• measuring result with “pass/fail” indication and acoustic
warning signal, if the test has been failed
• help function and schematic connecting diagrams
• separate 4 mm test sockets and IEC connector ST 750 A
• 3 x USB interface for PC, external keyboard and RFID reader/writer
• 1 x RS 232 interface for barcode scanner, printer and SD card slot
• free firmware update possible via SD card/USB stick

Measuring functions
• protective conductor resistance with 200 mA DC and a testing
current of 10 A AC
• insulating resistance with a testing voltage of 50 V to 500 V (adjustable)
• protective conductor current/contact current via differential
current measurement method, alternative leakage current
by
measurement method or direct measurement a t ion
• functional test with indication of leakage current, mains voltage, A p plic s cr e e n!
load current, effective power, apparent power and measuring time touch
• testing of device connecting cables and extension cables
• testing of three-phase loads by means of optional measuring adapters Touchscreen
• additionally for VDE 0751-1: device leakage current, leakage
current of application part type B, type BF and type CF
TRUE RMS
BENNING ST 750 A Order recommendation
Appliance Tester (VDE 0701-0702, VDE 0751) • appliance tester BENNING ST 750 A item no. 050320
BENNING • software BENNING PC-Win ST 750 item no. 047001
ST 750 A
• barcode scanner item no. 009369
display 5.7“ colour LCD touchscreen, ¼ VGA
protective conductor resistance 1 mΩ – 20 Ω • barcode labels (1000 pieces) item no. 756301
insulation resistance 0.1 MΩ – 100 MΩ • test badges “next test”
protective conductor current/ (300 pieces) (see page 8) item no. 756212
contact current via differential
current measurement method,
0.05 mA – 25 mA
Leakage alternative leakage current
measurement method or Optional accessories for BENNING ST 750 A
CM 9 direct measurement measuring adapters for three-phase loads (passive)
device leakage current and for measurement of RPE, RISO and IEA
Active testing of leakage current of the applied part 0.05 mA – 25 mA 16 A CEE coupling, 5-pin - shock-proof plug item no. 044122
three-phase loads by for medical electrical devices 32 A CEE coupling, 5-pin - shock-proof plug item no. 044123
means of test procedures line test RPE, RISO, IPE, short-circuit test and continuity test Leakage Current Clamp BENNING CM 9 for measurement of diffe-
with BENNING CM 9
differential current clamp of phase conductor (L) and neutral conductor (N) rential current, protective conductor current, load current of loads
and measuring adapter voltage/current 1 V - 360 V/0.1 A - 16 A (see pages 7/8) item no. 044065
effective power/apparent power 20 W - 4000 W measuring adapters for leakage current clamp BENNING CM 9
interface 3 x USB, 1 x RS 232 single-phase, conductors led through individually and with double insulation
dimensions/weight 405 x 330 x 165 mm/approx. 6 kg shock-proof socket/shock-proof plug item no. 044131
scope of delivery tester in waterproof (IP 67), break-proof case, three-phase, conductors led through individually and with double insulation
test cable with alligator clip, appliance 16 A CEE-CEE, 5-pin item no. 044127
cable, input stylus, 2 GB SD card 32 A CEE-CEE, 5-pin item no. 044128
044127/044128 item no. 050310 See pages 18 and 19 for further accessories
BENNING World Class Test Equipment
11
BENNING PC-Win ST 750 documentation software
helpful accessories for efficient testing
Software Portable log printer BENNING PT 1
BENNING PC-Win ST 750 with Bluetooth®
• professional PC software for the management and docu- • the perfect solution for printing test records rapidly on site
mentation of recorded measuring values • high printing speed due to direct thermal printing process
• explicit database structure with customer, department, test • data transmission via Bluetooth® or RS232 interface
sample and test result including the test date • power supply by means of rechargeable NiMH battery pack
• easily creating and copying customers and test samples • width/length of thermographic paper rolls: 58 mm/13 m
Software PC-Win ST 750 • printing of the test results as single log and serial log • included in delivery: 6 V battery pack, mains supply BENNING PT 1 printer
• bidirectional data transmission PC BENNING ST 750 A unit, belt clip, wall fastening, Bluetooth® dongle for
• import and export function of existing test sample and cus- BENNING ST 750, 2 rolls of thermographic paper and
tomer databases via MS Excel® RS232 cable
• free software update to the latest version available per
download

Roll of thermographic
paper
Test sample identification via Compact
barcode scanner/labels industrial keyboard
Barcode label • particularly suited for repetitive testing and identification of • high-quality functional keyboard with integrated trackball
large test sample inventories in offices, administrations etc. for comfortable input of test sample/customer data on site
• highly adhesive PVC barcode labels with barcode and con- • compact keyboard dimensions for
secutive numbering (reels of 1000 pieces) safe transport in the BENNING
• barcode scanner with RS 232 interface supports all ST 750 A appliance tester
conventional barcodes such as UPC/EAN/JAN, Code 39, • data transmission via Bluetooth® or
Code 128 etc. USB interface
• increased protection against dust
and splash water

industrial keyboard

Test sample identification via


Barcode scanner
RFID reader/writer or transponder
• test sample identification via radio frequency (“Radio Frequency
Identification”) without visual contact or direct contact of the
transponder
• RFID technology stores the test sample data/measuring values Tag-type Ring clip
transponder transponder
directly onto a memory chip (transponder) on the test sample
• particularly suited for rough industrial environments
• tag-type transponder for attachment by means of cable ties
• ring clip transponder for attachment to the mains supply line
• epoxy resin transponder (self-adhesive) for attachment into Self-adhesive epoxy
the housing or onto the surface of the housing resin transponder
• transponder frequency: HF 13.56 MHz; memory depth:10 kbit RFID reader/writer

Optional accessories for BENNING ST 750 A


software BENNING PC-Win ST 750 industrial keyboard
on CD-ROM incl. USB cable item no. 047001 with USB interface item no. 044154
barcode scanner RFID reader/writer
with RS 232 interface item no. 009369 with USB interface item no. 009370
barcode labels with consecutive numeric representation RFID transponder, tag-type, height/width: 43 x 34 mm
(1000 pieces) item no. 756301 (100 pieces) item no. 044139
printer BENNING PT 1 RFID transponder, ring clip, inside diameter: 7.5 mm
with Bluetooth® and RS 232 interface item no. 044150 (100 pieces) item no. 044138
roll of thermographic paper RFID transponder, self-adhesive, diameter/height: 17 mm/2.5 mm
(20 pieces) item no. 044151 (100 pieces) item no. 044137
See pages 18 and 19 for further accessories
BENNING World Class Test Equipment
12
Safety Instruments BENNING IT 101, IT 110 and IT 120 B
testing of electrical systems in compliance with the standards
BENNING IT 101 BENNING IT 110, BENNING IT 120 B
Insulation and Resistance Measuring Device Installation Testers
• measurement of insulating resistance and calculation of For safety tests on electrical systems
the resulting leakage current according to DIN VDE 0100 and IEC 60364
• testing voltages of 50 V, 100 V, 250 V, 500 V and 1000 V Multifunctional installation testers for complete testing and
• selectable limiting values for ISO measurement, green LED efficient troubleshooting of electrical systems
for “PASS”, red LED for testing voltage/external voltage • measurement of the protective conductor line and of the
• resistance measurement with a testing current of 200 mA equipotential bonding line with a testing current of 200 mA
for testing protective conductor connections • measurement of the insulation resistance with testing volt-
• measurement of polarization index (PI) and dielectric ages of 100 V, 250 V, 500 V and 1000 V
absorption rate (DAR) • line impedance and loop impedance measurement (optional
• switchable probe tip for triggering the measuring process without tripping of the RCD) with calculation of the short-
• internal memory for 100 measuring values per measuring function circuit current (PFC/PSC)
• TRUE RMS voltage measurement with low-pass filter • complete testing of RCDs with nominal fault currents of
• including case, switchable probe tip, silicone measuring 10/30/100/300/500/1000 mA
leads, magnetic hook, alligator clips, rubber protective • measurement of contact voltage (without tripping), tripping
frame and batteries time and tripping current (ramp test) of residual current
operated device (RCD)
• phase-sequence testing in three-phase mains
• voltage measurement up to 500 V and online voltage moni-
toring

IT 110

BENNING IT 110
Installation Tester
CAT IV 600 V
BENNING
TRUE RMS IT 110
IT 101 BENNING TA 5 display graphic display (illuminated)
low-impedance resistance 0.01 Ω – 2000 Ω
insulation resistance 1 kΩ – 1000 MΩ
BENNING IT 101
line impedance (L-N/L) 0.01 Ω – 2000 Ω
Insulation and Resistance Measuring Device
loop impedance (L-PE) 0.01 Ω – 2000 Ω
BENNING short-circuit current 0.01 A – 24.4 kA
IT 101 RCD testing tripping time, tripping current,
indicating range 4000 digits (illumination) type AC, A contact voltage
low-impedance resistance 0.01 Ω – 40 Ω phase sequence yes
insulation resistance 1 kΩ – 20 GΩ voltage, frequency 1 V – 500 V, 45 Hz – 65 Hz
resistance 0.01 Ω – 40 kΩ item no. 044100
voltage 0.1 V – 600 V AC/DC TRUE RMS
supplementary function leakage current, polarization index (PI),
dielectric absorption rate (DAR), automatic Optional accessories for
discharge function, null balance of the BENNING IT 101/IT 110/IT 120 B
measuring leads 40 m measurement cable BENNING TA 5 with practical winder, strap,
measured value memory 500 measuring results for the measurement of protective and bonding conductors,
measuring category CAT IV 600 V connection: Ø 4 mm safety test
Scope of delivery BENNING IT 101 item no. 044033 item no. 044039
BENNING World Class Test Equipment
13
BENNING IT 110, IT 120 B Installation Testers
the perfect solution for efficient testing
Features Logging software with Test Log according to ZVEH
BENNING IT 110, BENNING IT 120 B BENNING PC-Win IT 120 B
• all measuring functions can be selected directly by means • PC software for reading the stored test data
of a rotary switch • creation of test logs with handover and status report
• switchable probe tip for releasing the measuring process according to ZVEH
• graphic display and help function with connecting diagram • structuring and export function of the test data
• complete measuring result with measuring parameters,
limiting value and symbols for PASS/FAIL
• current supply by means of 6 NiMH storage batteries (AA)
with charger

Additional functions
BENNING IT 120 B
in addition to the BENNING IT 110 :
• testing of universal current-sensitive RCDs of type B
• current measurement (TRUE RMS) by means of current Test log to
g
clamp adapter (optional) accordin
• illumination measurement by means of lux sensor (optional) ZVEH
• earthing measurement by means of three-wire measuring
method (optionally with earthing set)
• integrated measured value memory for 500 measurements
• USB and RS 232 interface
• BENNING PC-Win IT 120 B software included in delivery

Scope of delivery of the BENNING IT 120 B

AddIn for Mebedo


test software
ELEKTROmanager
and fundamed

INFORMATION:
RCDs of type B are increa-
singly used for multi-phase
equipment of power elec-
tronics. In case of a fault, BENNING CC 2
these devices also detect
smooth DC fault currents
rsal
of unive IT 120 B and high-frequency AC fault
Testing ensitive
s
current- type B currents.
RC Ds o f

BENNING IT 120 B Scope of delivery of the installation testers


Installation Testers BENNING BENNING
BENNING IT 110 IT 120 B
IT 120 B tester incl. carrying case / carrying strap x x
display graphic display (illuminated) switchable probe tip x x
low-impedance resistance 0.01 Ω – 2000 Ω test cable with shock-proof plug x x
insulation resistance 1 kΩ – 1000 MΩ universal test cable, 3 x L = 1.5 m x x
line impedance (L-N/L) 0.01 Ω – 2000 Ω 3 x test probe, 3 x crocodile clips x x
loop impedance (L-PE) 0.01 Ω – 2000 Ω charger with 6 NiMH storage batteries (AA) x x BENNING luxmeter
short-circuit current 0.01 A – 24.4 kA PC software BENNING PC-Win IT 120 B x type B
RCD testing tripping time, tripping current, USB and RS 232 cable x
type AC, A, B contact voltage
phase sequence yes
voltage, frequency 1 V – 500 V, 45 Hz – 65 Hz Optional accessories for BENNING IT 120 B
earth resistance 0.01 Ω – 2000 Ω current clamp adapter BENNING CC 2
current (TRUE RMS) 0.1 mA – 20 A (by means of the clamp) 0.5 A – 20 A AC (200 A AC) item no. 044110
luminous intensity 0.01 lux – 20 klux (by means of sensor) illumination sensor BENNING luxmeter type B
measured value memory 500 measuring results Accuracy: 5 % item no. 044111
interfaces USB, RS 232 earthing set consisting of 2 earth rods and 3 test cables
incl. software BENNING PC-Win IT 120 B (2 x L = 20 m, 1 x L = 4.5 m) item no. 044113
item no. 044102

Earthing set
BENNING World Class Test Equipment
14
BENNNG PV 1-1 installation tester for photovoltaic systems
Commissioning tests and periodic inspection of PV systems
BENNING PV 1-1 Application
PV installation tester for testing For commissioning tests and periodic inspection of grid-con-
grid-connected PV systems nected PV systems according to VDE 0126-23. Meets all
• tests in compliance with VDE 0126-23 (DIN EN 62446) requirements necessary for system documentation of the
standard DC side. Ideal for troubleshooting, maintenance work and
• easy – operation by means of keys with AUTO test procedure performance evaluation of PV systems.
• quick – testing within a few seconds only
• safe – contacting by means of PV connectors Features of the BENNING PV 1-1
• easy and safe operation by means of keys
• automatic test procedure for polarity, open-circuit voltage,
short-circuit current and insulating resistance
• RISO measurement with “PASS/FAIL” indication
• memory of measured values for 200 PV strings
• integrated real-time clock with date/time stamp for each
measurement
• USB interface and download software for the preparation of
test certificates in MS Excel®
• safe contacting even during energy supply of the PV system
• direct connection by means of MC4 and “Sunclix” connectors
Measured values transmitted
via wireless connection
Measuring functions
• continuity test of the protective conductor and of the
equipotential bonding conductor with a testing current of
200 mA
• polarity test of the DC current cables
• open-circuit voltage for each PV string of up to 1000 VDC
• short-circuit current for each PV string of up to 15 ADC
• insulating resistance with a testing voltage of 250 V, 500 V
and 1000 VDC
• DC string current and AC current by means of BENNING CC 3
current measuring clamp up to 40 A AC/DC (optional)

Radio interface “Wireless SUN Link”


• wireless connection to the insolation and temperature
measurement instrument BENNING SUN 2 (optional)
• direct display of the insolation value in W/m2
• storage of the electric quantities to be measured consider-
ing the insolation and the module/ambient temperature in
real time

BENNING PV 1-1
Installation tester for photovoltaic systems
BENNING
PV 1-1
display graphic display (illuminated)
protective conductor
0.05 Ω – 199 Ω
resistance
insulating resistance 0.2 MΩ – 199 MΩ BENNING CC 3 BENNING TA 5
open-circuit voltage
5 V to 1000 V DC
with polarity
short-circuit current 0.5 A to 15 A DC
DC string current/ 0.2 A to 40 A DC/AC
AC current (by means of BENNING CC 3) Optional accessories for
insolation 100 to 1250 W/m2 BENNING PV 1-1
(by means of BENNING SUN 2) Current clamp adapter BENNING CC 3 for AC/DC current measurement
PV module/ambient -30 °C to +125 °C 0.2 to 300 A AC/DC item no. 044038
temperature (by means of BENNING SUN 2) Measuring line BENNING TA 5 for protective conductor measurement
voltage via 4 mm sockets 30 to 440 V AC/DC Line length: 40 m item no. 044039
Interface/radio interface 1 x USB/433 MHz signal
dimensions/weight 270 x 115 x 55 mm/2.6 kg
scope of delivery carrying case, measuring lines,
BENNING PV 1-1 alligator clips, MC4 and “Sunclix”
scope of delivery PV measuring lines, batteries, USB cable,
download software on CD-ROM
item no. 050421
BENNING World Class Test Equipment
15
Insolation and temperature measuring instrument BENNING SUN 2
with digital compass and inclinometer
BENNING SUN 2 Measuring functions
Insolation and temperature measuring instrument • insolation measurement in W/m2 or BTU/h/ft2
for PV systems and solar thermal systems • dual-channel temperature sensor for measuring the module
Ideal for the planning, commissioning tests and periodic temperature and the ambient temperature
inspection of grid-connected PV systems according to • digital compass for determining the cardinal direction
VDE 0126-23 as well as for testing solar thermal systems. • inclinometer for determining the module/roof pitch

Features of the BENNING SUN 2


• universal 4-in-1 measuring instrument for all testing and
maintenance work as well as for economic efficiency analysis
• temperature-compensated PV reference cell for precise in-
solation measurement
• precise temperature measurement by means of high-preci-
sion sensors
• data logger for 5000 data records, including insolation and
module/ambient temperature
• integrated real-time clock with date/time stamp
• USB interface and download software for the preparation of
test certificates in MS Excel®
• data logger with energy-saving stand-by mode
• shock-absorbing protective rubber holster

Radio interface – “Wireless SUN Link”


• wireless transmission of insolation, module temperature
and ambient temperature including date/time stamp to the
BENNING PV 1-1

Insolation, angle of inclination


and compass bearing

Wireless transmission of measuring data Insolation, PV module/ambient temperature


(alternatively import of measuring data by means of date/time stamp)

BENNING SUN 2
Insolation and temperature measuring instrument s
ort form
BENNING Test rep of PV systems”
ation
SUN 2
“Examin ee under
display graphic display fr
nning.de
insolation 100 to 1250 W/m2 www.be
PV module/ambient
-30 °C to +125 °C
temperature
compass bearing
0° to 360°
(orientation)
angle of inclination
0° to 80°
measurement
real-time clock date/time stamp
measured value memory 5000 data records for insolation
and temperature
interface/radio range 1 x USB/approx. 30 m for unobstructed
view conditions
dimensions/weight 150 x 80 x 33 mm/350 g
scope of delivery case, protective rubber holster,
module/ambient temperature sensor,
battery set, USB cable,
download software on CD-ROM BENNING SUN 2
item no. 050420 scope of delivery
BENNING World Class Test Equipment
16
Demonstration case for practice-oriented application
of testers, measuring instruments and safety instruments
BENNING DB 1 BENNING DB 2
Demonstration case for testing and measuring Demonstration case for practice-oriented application
primary quantities of electrical engineering and training concerning VDE 0100 installation testers
tion
r informa
For furthe r website
visit ou ing.de
n
www.ben

particularly suited for teaching and portable case for simulation of electrical
education purposes, training courses systems conforming to standards
and product presentations according to DIN VDE 0100/105

Demonstration case Demonstration case


BENNING DB 1 BENNING DB 2
power supply 230 V, 50/60 Hz mains connection power supply 230 V, 50/60 Hz mains connection
dimensions/weight 405 x 330 x 160 mm, approx. 6 kg dimensions/weight 450 x 330 x 110 mm, approx. 4.5 kg
scope of delivery case with mains connection cable scope of delivery case with mains connection cable
item no. 044132 item no. 044133

Recommendation for the workshop equipment for enterprises of electrical engineer-craft


according ZVEH and VDEW guidelines (Electricity Association)
Required test and Tester/meter Single unit Single unit/device combination Single unit/device combination
measurement complying with standard version I version II version III
Two-pole voltage tester DIN VDE 0682-401 DUSPOL® analog DUSPOL® expert DUSPOL® digital
IEC/EN 61243-3 item no. 050261 item no. 050262 item no. 050263
Voltage (min. 600 V) and DIN VDE 0411-1 MM 2 MM 1-3 + CC 1 MM 7-1 + CC 1
current meter (min. 15 A) IEC/EN 61010-1 item no. 044028 item no. 044084 + 044037 item no. 044085 + 044037
Clip-on ammeter DIN VDE 0411-1 CM 2 CM 5-1 CM 8
(min. 300 A) IEC/EN 61010-1 item no. 044035 item no. 044066 item no. 044064
Insulation tester DIN VDE 0413-2 IT 101
IEC/EN 61557-2 item no. 044033
Loop ohmmeter DIN VDE 0413-3

IEC/EN 61557-3
Ohmmeter DIN VDE 0413-3 IT 101 IT 110 IT 120 B
IEC/EN 61557-4 item no. 044033 item no. 044100 item no. 044102
FI/RCD-meter DIN VDE 0413-6

IEC/EN 61557-6
Phase sequence indicator DIN VDE 0413-7 TRITEST ®
IEC/EN 61557-7 item no. 020050
Instrument for testing
DIN VDE 0404-1 ST 710 ST 720 ST 750 A
electrical equipment
DIN VDE 0404-2 item no. 050308 item no. 050312 item no. 050320
(DIN VDE 0701-0702, 0751-1)

Additional recommendation ZVEH


Grounding gauge DIN VDE 0413-6 Earthing set for IT 120 B
– –
IEC/EN 61557-6 item no. 044113
Continuity tester DIN VDE 0413-7 DUTEST ®
IEC/EN 61557-7 item no. 050155
Light meter lux meter Luxmeter type B for IT 120 B
– – –
item no. 044111

Additional recommendation of BENNING


Differential current clamp for DIN VDE 0411-1
CM 9 CM 9 CM 9
error current determination in IEC/EN 61010-1
item no. 044065 item no. 044065 item no. 044065
electric equipment and systems DIN VDE 0404-4
BENNING World Class Test Equipment
17
Voltage and Continuity Tester
Phase-Sequence Indicator
PROFIPOL® DUTEST ® TRITEST ® control
Voltage Testers for universal applications Continuity and line tester Phase-sequence indicator for testing
• indicating DC and AC voltage within the • reliable detection of faulty wiring, contact- the phase sequence in three-phase
range of 6 – 400 V ing errors and cable interruptions mains
• indicating steps 6, 12, 50, 120, 230, 400 V • quick localization of defective fuses, lamps, • indication of clockwise and anti-clockwise
• polarity test for DC voltage lines and short-circuits phase sequence
• shock-proof housing made of rugged high- • indication of high-impedance (0 – 90 kΩ) • indication of phase voltages (L1, L2, L3) by
pressure PE material and low-impedance (0 – 900 Ω) resistances means of high-contrast LEDs
• compact dimensions and increased grip • acoustic indication by means of loud testing • voltage range: 400 – 690 V (50 – 60 Hz)
• dustproof and waterproof, protection buzzer • bright LED pocket lamp function
category IP 65 • visual indication by means of high-contrast • including safety probe tips and alligator clip
light-emitting diodes (LED)
• powerful torch function
• protected against external voltages of up to 400 V

PROFIPOL® DUTEST ® TRITEST ® control


item no. 020022 item no. 050155 item no. 020050

TRITEST ® easy
Non-contact phase/phase sequence
tester
• phase sequence testing in three-phase
mains
• phase testing on sockets and distribution
boxes
• testing with regard to phase balance
• testing insulated lines (cable reel, chains of
lights) of cable breaks
• indication via red/green probe tip and Phase sequence testing Testing of cable breaks
green = clockwise
buzzer
• ON/OFF push-button with automatic
switch-off
• voltage range: 200 V – 1000 V AC
• break-proof ABS housing and easy operation
CAT IV 600 V
• incl. Batteries and pen clip
TRITEST ® easy
item no. 020051
BENNING World Class Test Equipment
18
Accessories for BENNING testers and measuring instruments
safe – functional – indispensable
Hard-top case for testers and measuring instruments DUSPOL® stand-by case
item no. 711020 item no. 010911
High-quality hard-top case with foam insert and three com- Practical stand-by case with Velcro fastener and belt loop
partments for professional storage of testers and measuring made of hard-wearing nylon fabric suitable for DUSPOL®
instruments. digital, DUSPOL® expert and DUSPOL® analog.
Compartment dimensions: approx. 110 x 300 x 50 mm, Dimensions: 330 x 100 x 60 mm
Case dimensions: approx. 450 x 380 x 110 mm

BENNING TA 1
item no. 044124
Ø 4 mm safety crocodile clips, two pieces, red/black,
professional equipment, CAT III 1000 V

BENNING TA 2
item no. 044125
set of Ø 4 mm safety measuring leads, six pieces,
red/black, professional equipment, consisting of:
• safety measuring leads (silicone), CAT III 1000 V
• safety test probes (4 mm measuring tip), CAT II 1000 V
• safety crocodile clips, CAT III 1000 V

BENNING TA 3
item no. 044126
set of Ø 4 mm safety measuring leads, eight pieces,
red/black, professional equipment, CAT III 1000 V,
consisting of:
• safety measuring leads (silicone)
• safety test probes (slender measuring tip)
• safety claw clamps
• safety crocodile clips

BENNING TA 4 Ø 4 mm safety measuring leads


item no. 044120 with 2 mm measuring tip item no. 044146
magnetic holder for Multimeter and Ø 4 mm safety measuring leads 2 pieces,
BENNING IT 101, 3 pieces, consisting of: red/black, L = 1.40 m, with 2 mm
• magnetic holder measuring tip CAT IV 600 V/
• adapter and belt, for attachment of CAT III 1000 V (with protective caps),
BENNING Multimeters to switching CAT II 1000 V (without protective caps)
cabinets, machine and system parts

Ø 4 mm safety measuring leads


with 4 mm measuring tip item no. 044145
Ø 4 mm safety measuring leads 2 pieces,
BENNING TA 5 red/black, L = 1.40 m, with 4 mm
item no. 044039 measuring tip CAT IV 600 V/
40 m measurement cable with practical winder, strap, for the CAT III 1000 V (with protective caps),
measurement of protective and bonding conductors, CAT II 1000 V (without protective caps)
Connection: Ø 4 mm safety test

Set of safety measuring leads for BENNING MM 4 Temperature probe (type K)


item no. 044119 item no. 044121
set of Ø 4 mm safety measuring leads, 3 pieces, insertion probe (V4A steel tube) for flexible substances,
consisting of: liquids, gases and air, measuring range:
• safety measuring leads with 2 mm measuring tip -196 °C to +800 °C, suitable for BENNING MM 1-3, MM 7-1,
• 2 measuring probes with 2 mm measuring tip MM 11 and CM 8 digital measuring instruments
BENNING World Class Test Equipment
19
Measuring adapters for BENNING ST 710/ST 720/ST 750 A
appliance testers and BENNING CM 9 leakage current clamp
Measuring adapters for BENNING ST 710/ST 720/ST 750 A

Measuring adapters for single-phase loads (passive)


for measuring RPE, RISO and IEA, CEE coupling (3-pin) with
shock-proof plug
16 A CEE (3-pin) item no. 044143
32 A CEE (3-pin) item no. 044144 for ST 710/720/750 A

Measuring adapters for three-phase loads (passive)


for measuring RPE, RISO and IEA, CEE coupling (5-pin) with
shock-proof plug
16 A CEE (5-pin) item no. 044122
32 A CEE (5-pin) item no. 044123 for ST 710/720/750 A

Measuring adapter for single-phase and three-phase


loads (passive)
for measuring RPE, RISO and IEA, triple CEE coupling with
shock-proof plug
Triple CEE coupling: 16 A CEE (5-pin), 32 A CEE (5-pin),
16 A CEE (3-pin) item no. 044147
for ST 710/720/750 A

Measuring adapter for BENNING ST 710/ST 720


Shock-proof plug with 4 mm plug for appliances without
shock-proof plug
item no. 044142

for ST 710/720

Measuring adapters for BENNING ST 720 (active)


Measuring adapters for three-phase loads for measuring
RPE and IPE (direct measurement method) by means of current
transformer, CEE (5-pin) with shock-proof plug
16 A CEE (5-pin) item no. 044140
32 A CEE (5-pin) item no. 044141
for ST 720

Measuring adapters for BENNING CM 9 leakage current


clamp (active)
for measuring the differential/protective conductor/load current,
conductors led through individually, with double insulation
Single-phase,
for CM 9
shock-proof plug/coupling item no. 044131

Three-phase,
16 A CEE (5-pin) item no. 044127
32 A CEE (5-pin) item no. 044128
for CM 9

BENNING CM 9 leakage current clamp


for measuring the differential/protective conductor/load current
(test sample working)

of single-phase and three-phase loads (1 µA to 100 A AC)


(see page 7)
item no. 044065

indication= ID IPE
TRUE RMS ID = IPE + IL
IL Leakage current e.g. via
the water conduit and
capacity of the washing
©

machine to earth
BENNING World Class Test Equipment
20
Professional VDE seminars
Service hotline with 24h service
VDE 0701-0702 seminar VDE 0100 seminar
Testing of electrical appliances/equipment Testing of electrical installations of up to 1000 V
Features: Features:
The seminar addresses qualified electricians, competent The seminar addresses qualified electricians who have to do
persons as well as electrotechnically trained persons who have the testing and its documentation of electrical installations of
to do the testing and its documentation according to the DIN up to 1000 V according to the DIN VDE 0100 standard.
VDE 0701-0702 standard for repaired or modified electrical The participants of the seminar will be given an intensive
devices or the repetitive testing of electrical devices. training in order to be able to do this inspection independently
The participants of the seminar will be given an intensive and according to regulations considering the optimum use of
training in order to be able to do this inspection according to the BENNING IT 101/IT 110/IT 120 B testers as well as of the
regulations considering the optimum use of the BENNING BENNING PC-Win IT 120 B logging software. At the end of the
ST 710/ST 720/ST 750 A testers as well as of the BENNING seminar, the participants will get a certificate of attendance.
PC-Win ST 750 logging software. At the end of the seminar,
the participants will get a certificate of attendance. Content:
Regulations, definitions, measurements (insulation, continuity
Content: of the protective conductor, loop impedance/line impedance,
Regulations, definitions, measurements (continuity of the pro- short-circuit current, FI/RCD testing, earthing, rotary field,
tective conductor, insulation, protective conductor current/con- voltage, frequency), management of measuring data and docu-
tact current), test sample management and documentation mentation according to ZVEH.
according to ZVEH.
Seminar venue: BENNING GmbH & Co. KG,
VDE 0126-23 seminar Robert-Bosch-Straße 20, 46397 Bocholt
Testing of grid-connected photovoltaic systems Seminar dates: to be agreed upon
Features: Seminar fee: We are happy to make you an offer:
The seminar is intended for qualified electricians who have to phone +49 (0) 28 71/93 - 470
carry out commissioning tests and periodic inspection of grid- Duration: 4 or 6.5 hours
connected photovoltaic systems in compliance with the Scope of services: Intensive training in small groups of up
VDE 0126-23 standard. The participants of the seminar will be to 6 persons, training material, certifi-
given an intensive training in order to be able to do this inspec- cate of attendance and refreshments
tion according to regulations considering the optimum use of during the seminar
the photovoltaic tester BENNING PV 1-1 as well as of the inso- We are pleased to send you our directions and to recommend to
lation and temperature measuring instrument BENNING SUN 2. you hotels in direct vicinity of the seminar venue.

Content:

Printed on non-chlorine bleached paper.


Regulations, testing of the AC side, testing of the DC side (po-
larity test, open-circuit voltage, short-circuit current, insulating free
e
2 4 h s e r v ic
resistance and operating current measurement for each PV
string of the PV generator) as well as minimum requirements
ne:
for system documentation in compliance with VDE 0126-23. Service Hotli - 555
/93
+49 (0) 28 71
Testing, measuring and safety instruments 784331.32 GB 01/2014 paus Design & Medien, Bocholt Subject to technical changes.

The whole range of testers from one supplier


Developing safe and practical testing and measuring instru-
ments which comply with the relevant standards is an
integral part of BENNING’s product philosophy for more than
65 years now. Today, BENNING offers a comprehensive prod-
uct range of high-quality testing, measuring and safety
Factory II, Robert-Bosch-Straße 20, D-46397 Bocholt devices the quality requirements of which are orientated
according to the demands of professional users. With the
generation of DUSPOL® voltage testers and with the measur-
ing and safety devices, BENNING sets pioneer standards
Your distributor: worldwide concerning safety, functionality and design.

BENNING Elektrotechnik und Elektronik GmbH & Co.KG


Münsterstraße 135-137 • D-46397 Bocholt
Tel.: + 49 / (0) 2871 / 93-420 • Fax: + 49 / (0) 2871 / 93-429
www.benning.de • E-Mail: duspol@benning.de

You might also like