Air-Cooled Screw Chillers RTAF 300-1600 KW: The Best Bundled in One. Our Best
Air-Cooled Screw Chillers RTAF 300-1600 KW: The Best Bundled in One. Our Best
Air-Cooled Screw Chillers RTAF 300-1600 KW: The Best Bundled in One. Our Best
RTAF 300-1600 kW
The best bundled in one.
Our best.
1
Trane Sintesis
The best bundled in one. Our best.
The best buildings demand the best in HVAC. We have combined the best efficiency and
performance in one system. Trane Sintesis provides leading temperature control in the
most demanding applications. Exceptional efficiency keeps your operating costs low.
Smart but easy to use controls ensure you get the best out of your system day after day,
year after year.
Quiet
Operating noise is a significant intrusion into a sensitive building environment. The Sintesis range is simply the quietest
system on the market. No compromise in operational efficiency has been made in providing a choice of three levels of
noise attenuation.
Reliable
With equipment as critical as an HVAC system, quality is non-negotiable. At Trane we manufacture and design the core
components and put our systems through extremely demanding performance and reliability tests. As a result, we have
the confidence to offer exceptional warranty cover of up to ten years.
Smart
The Trane Sintesis range is the smartest solution on the HVAC market. It has the capability to provide all-year cooling
in ambients from -18°C up to 55°C. It is ideally suited to industrial applications and is Ecodesign 2016 compliant.
Operation could not be easier thanks to smart controls and a user-friendly touchscreen interface. And connectivity with
Modbus, BACnet®, LonTalk® and Trane BMS is simple with the Smart Com interface.
3
Trane Proprietary Technology*
provides the innovative solution your building needs
* Connectivity
• Full interoperability via SmartCom interface Lontalk®,
BACnet® and Modbus
• Full remote control capability via our Trane BMS
* Trane Compressor
• Direct drive, two screws helical rotary design
• Infinite capacity modulation via the slide valve
• Trane legendary reliability
5
The Total Package
Quality, performance and reliability
Trane solutions optimize indoor environments with a broad portfolio of energy efficient heating, ventilating and air
conditioning systems, building services, parts support and advanced controls.
To ensure your equipment continues to work at its optimum, throughout the life of the building, Trane provides a full range
of service solutions, combined with in-house expertise and an extensive support network.
Smart Reliable
7
Outstanding energy efficiency
Exceptional efficiency means less energy consumed and lower electricity bills.
Choose from five efficiency versions:
Standard Efficiency: SE
• EER > 2.85
• ESEER > 3.84
High Efficiency: HE
• EER > 3.00
• ESEER > 3.82
Extra Efficiency: XE
• EER > 3.03
• ESEER > 4.11
High Seasonal Short: HSS
• Adaptive Frequency Drive, inverter technology
• ESEER up to 4.55
• EER up to 3.16
High Seasonal Efficiency: HSE
• Adaptive Frequency Drive, inverter technology
• ESEER up to 4.77
• EER up to 3.29
- Compressor enclosure
- Refrigerant line insulation
- EC fans with top diffusers * The lowest noise rating on the market.
Sound levels
104
102
100
Sound power level - Lw in dB(A)
98 RTAF XE SN
96
94 RTAF XE LN
92
90 RTAF XE XLN
88
86
200 400 600 800 1000 1200 1400
(1) At evaporator water temperature: 12°C / 7°C - Condenser air temperature 35°C according to EN14511:2013
(2) Rated condition without pump package
(1) At evaporator water temperature : 12°C / 7°C - Condenser air temperature 35°C according to EN14511:2013
(2) Rated condition without pump package
11
HSE/HSS
Trane Adaptive Frequency Drive
60000
50000
40000
30000
20000
10000
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
6
Unit effiency (EER)
0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Chiller load (%)
EER RTAF 145 SE-SN
EER RTAF 145 HSE-SN
SE/HE/XE
R134a
HSE/HSS ODP = 0
RTAF HSE-SN / HSE-LN High Seasonal Efficiency - Standard and Low Noise
RTAF 090 RTAF 105 RTAF 125 RTAF 145 RTAF 155 RTAF 175 RTAF 190 RTAF 205
Eurovent performances (1)
HSE /HSS
HSE HSE HSE HSE HSE HSE HSE HSE
Net cooling capacity (kW) 330 383 452 534 576 638 695 755
EER 3.26 3.17 3.11 3.19 3.10 3.07 3.10 3.07
ESEER 4.42 4.37 4.55 4.71 4.61 4.53 4.53 4.53
Eurovent efficiency class cooling A A A A A B A B
Sound power level (standard
(dBA) 94 94 95 96 97 97 98 98
noise)
Sound power level (low noise) (dBA) 91 91 92 93 94 94 95 95
Dimensions
Unit length (mm) 5645 5645 5645 6770 6770 6770 7895 7895
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2526 2526 2526 2526 2526 2526 2526 2526
XLN
Weights (2)
Operating weight (kg) 3705 3765 3945 4450 4760 4915 5405 5520
RTAF 245 RTAF 250 RTAF 280 RTAF 310 RTAF 350 RTAF 380 RTAF 410 RTAF 450
Eurovent performances (1) HSE HSE HSE HSE HSE HSE HSE HSE
Net cooling capacity (kW) 875 882 999 1118 1243 1369 1473 1586
EER 2.85 3.03 3.04 3.04 3.03 3.04 2.97 2.84
ESEER 4.29 4.40 4.43 4.46 4.59 4.62 4.56 4.41
Eurovent efficiency class cooling C B B B B B B C
Sound power level (standard
(dBA) 104 99 100 101 101 102 102 109
noise)
Sound power level (low noise) (dBA) 101 97 98 99 99 99 100 107
Dimensions
Unit length (mm) 7895 9390 10135 11260 12385 13510 13510 13510
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2526 2526 2526 2526 2526 2526 2526 2526
Weights (2)
Operating weight (kg) 5520 7099 7599 8099 9399 9699 9899 9899
RTAF 245 RTAF 250 RTAF 280 RTAF 310 RTAF 350 RTAF 380 RTAF 410 RTAF 450
Eurovent performances (1) HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN
Net cooling capacity (kW) 875 882 999 1117 1243 1369 1472 1585
EER 2.88 3.06 3.08 3.07 3.06 3.08 3.00 2.86
ESEER 4.36 4.51 4.51 4.53 4.66 4.69 4.63 4.51
Eurovent efficiency class cooling C B B B B B B C
Sound power level (dBA) 97 93 94 95 95 95 95 103
Dimensions
Unit length (mm) 7895 9390 10135 11260 12385 13510 13510 13510
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2672 2672 2672 2672 2672 2672 2672 2672
Weights (2)
Operating weight (kg) 5660 7099 7599 8099 9399 9699 9899 9899
(1) At evaporator water temperature : 12°C / 7°C - Condenser air temperature 35°C according to EN14511:2013
(2) Rated condition without pump package
13
R134a
ODP = 0
RTAF HSS-SN / HSS-LN High Seasonal Short - Standard and Low Noise
RTAF 090 RTAF 105 RTAF 125 RTAF 145 RTAF 155 RTAF 175 RTAF 190
Eurovent performances (1) HSS HSS HSS HSS HSS HSS HSS
Net cooling capacity (kW) 330 378 445 529 571 621 681
EER 3.11 3.03 2.94 3.08 2.98 2.90 2.98
ESEER 4.24 4.17 4.33 4.44 4.38 4.38 4.40
Eurovent efficiency class cooling A B B B B C B
Sound power level (standard noise) (dBA) 95 95 95 96 96 97 97
Sound power level (low noise) (dBA) 92 92 92 93 93 94 94
Dimensions
Unit length (mm) 4520 4520 4520 5645 5645 5645 6770
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2526 2526 2526 2526 2526 2526 2526
Weights (2)
Operating weight (kg) 3421 3472 3629 4149 4450 4575 5110
RTAF 205 RTAF 250 RTAF 280 RTAF 310 RTAF 350 RTAF 380 RTAF 410
Eurovent performances (1) HSS HSS HSS HSS HSS HSS HSS
Net cooling capacity (kW) 736 866 979 1077 1200 1330 1450
EER 2.92 2.92 2.92 2.81 2.82 2.87 2.88
ESEER 4.39 4.37 4.27 4.23 4.40 4.45 4.49
Eurovent efficiency class cooling B B B C C C C
Sound power level (standard noise) (dBA) 97 99 100 101 101 102 102
Sound power level (low noise) (dBA) 94 97 98 99 99 99 100
Dimensions
Unit length (mm) 6770 8265 9390 9390 10135 11260 12385
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2526 2526 2526 2526 2526 2526 2526
Weights (2)
Operating weight (kg) 5218 6700 7300 7500 8500 9000 9400
RTAF 190 RTAF 205 RTAF 250 RTAF 280 RTAF 310 RTAF 350 RTAF 380 RTAF 410
Eurovent performances (1) HSS-XLN HSS-XLN HSS-XLN HSS-XLN HSS-XLN HSS-XLN HSS-XLN HSS-XLN
Net cooling capacity (kW) 681 735 866 979 1076 1199 1329 1450
EER 3.01 2.95 2.94 2.94 2.83 2.84 2.89 2.90
ESEER 4.48 4.46 4.44 4.34 4.30 4.48 4.53 4.55
Eurovent efficiency class cooling B B B B C C C C
Sound power level (dBA) 91 91 93 94 94 94 95 95
Dimensions
Unit length (mm) 6770 6770 8265 9390 9390 10135 11260 12385
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2526 2526 2672 2672 2672 2672 2672 2672
Weights (2)
Operating weight (kg) 5230 5338 6799 7399 7599 8599 9099 9499
(1) At evaporator water temperature : 12°C / 7°C - Condenser air temperature 35°C according to EN14511:2013
(2) Rated condition without pump package
15
SE/HE/XE
RTAF 250 RTAF 280 RTAF 310 RTAF 350 RTAF 380 RTAF 410
Eurovent performances (1) SE-XLN SE-XLN SE-XLN SE-XLN SE-XLN SE-XLN
Net cooling capacity (kW) 860 973 1075 1195 1324 1447
EER 3.02 3.01 2.90 2.90 2.94 2.95
ESEER 4.26 4.25 4.23 4.36 4.45 4.44
Eurovent efficiency class cooling B B B C B B
Sound power level (dBA) 93 94 94 94 95 95
Dimensions
Unit length (mm) 8265 9390 9390 10135 11260 12385
Unit width (mm) 2200 2200 2200 2200 2200 2200
Unit height (mm) 2672 2672 2672 2672 2672 2672
Weights (2)
Operating weight (kg) 6599 7199 7399 8399 8999 9299
(1) At evaporator water temperature: 12°C / 7°C - Condenser air temperature 35°C according to EN14511:2013
(2) Rated condition without pump package
RTAF 245 RTAF 250 RTAF 280 RTAF 310 RTAF 350 RTAF 380 RTAF 410 RTAF 450
Eurovent performances (1) HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN HSE-XLN
Net cooling capacity (kW) 875 882 999 1117 1243 1369 1472 1585
EER 2.88 3.06 3.08 3.07 3.06 3.08 3.00 2.86
ESEER 4.36 4.51 4.51 4.53 4.66 4.69 4.63 4.51
Eurovent efficiency class cooling C B B B B B B C
Sound power level (dBA) 97 93 94 95 95 95 95 103
Dimensions
Unit length (mm) 7895 9390 10135 11260 12385 13510 13510 13510
Unit width (mm) 2200 2200 2200 2200 2200 2200 2200 2200
Unit height (mm) 2672 2672 2672 2672 2672 2672 2672 2672
Weights (2)
Operating weight (kg) 5660 7099 7599 8099 9399 9699 9899 9899
(1) At evaporator water temperature: 12°C / 7°C - Condenser air temperature 35°C according to EN14511:2013
(2) Rated condition without pump package
17
The Future of F-Gases
The fluorinated refrigerants phase-down, as defined in the new EU F-Gas
Regulation, is a step-by-step approach where the quantities of HFCs expressed
in CO2 equivalent that are placed on the market are gradually reduced. As a
result of the phase-down, HFC consumption will be reduced by 79% by 2030.
This is an unprecedented reduction and means that industry and users need
to make, over time, the transition to refrigerants with a lower global warming
potential.
HFC consumption
100%
93%
90%
80%
70%
63%
60%
50% 45%
40%
31%
30%
24% 21%
20%
10%
0%
2015 2016 2018 2021 2024 2027 2030
Baseline value (100%) is the annual average of total quantity of CO2 equivalents placed on the EU market from 2009 to 2012.
• High efficiency operation – To deliver lower operating • Low GWP refrigerant option – Sintesis chillers are
costs, Sintesis chillers are optimized for both full- and designed to operate with either R-134a or DuPont™
part-load performance. Opteon® XP10 (R-513A), a next-generation refrigerant
with a 55 percent lower GWP than R-134a.
• Lower refrigerant charge – The CHIL evaporator
and microchannel condenser reduce the amount of • Reduced risk of refrigerant leaks – The microchannel
refrigerant required by up to 40 percent compared to design used in Sintesis chillers eliminates brazed U-bend
earlier designs, making it even easier to earn a point connections and their potential for refrigerant leaks,
under the LEED® Energy and Atmosphere (EA) Credit for helping maintain peak chiller efficiency and reliability.
Enhanced Refrigerant Management.
What is GWP?
GWP is the global warming impact relative to the impact of the
same quantity of carbon dioxide over a 100 year period.
Example:
CO2 : GWP = 1
R134a: GWP = 1430
R513A: GWP = 631 (55% below R134a)
19
Range Description
a model for every application
Factory mounted options This is available all year-round, in all regions no matter
• Hydraulic kit with dual pumps how hot or cold it gets.
• Smart flow control • Standard ambient option: from -10°C to 46°C
• Partial heat recovery • High ambient option: right up to 55°C
• Total heat recovery • Low ambient option: right down to -18°C
• Free-cooling
Trane® is a brand of Ingersoll Rand®. Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sus-
tainable and efficient environments. Our people and our family of brands—including Ingersoll Rand®, Trane®,
Thermo King® and Club Car® — work together to enhance the quality and comfort of air in homes and buildings; transport
and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed
to a world of sustainable progress and enduring results.
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.
Trane bvba, Lenneke Marelaan 6, 1932 Sint-Stevens-Woluwe, Belgium, ON 0888.048.262 - RPR Brussels
We are committed to using environmentally conscious print practices that reduce waste. © 2015 Trane – All rights reserved
RTAF-SLB001-GB June 2015