Kyowa EDX 200A Catalog
Kyowa EDX 200A Catalog
Kyowa EDX 200A Catalog
EDX-200A-1
EDX-200A-2H
EDX-200A-4H EDX-200A-4T
Except EDX-200A-4T and EDX-200A-4T-0
3-57
Dual Mode High-speed sampling (Expressed as Sf)
1-2-5 series 1 Hz to 100 k Hz
2n series 2 Hz to 65536 Hz
Low-speed sampling (Expressed as "Ss")
1-2-5 series The division frequencies from
high-speed sampling, and Ss ≤ Sf/4
Interval Measurement
Automatically recording functions based upon
previously-set interval conditions
Combination with measured mode when in
dual sampling
High-speed sampling channel Low-speed sampling channel
Manual Manual
3
-58
2n series The division frequencies from Manual
Trigger
high-speed sampling, and Ss ≤ Sf/4 Interval
Acquisition Channels Interval Interval
MEASURING INSTRUMENTS
Normal Mode Max. 32 channels, 320 k/I (I is the integer part of the Recording Start/Stop PC, operation switch (panel screen),
set sampling frequency.) or using dedicated remote control
Dual Mode Max. 64 channels, 320 k/I (I is the integer part of the Balance Adjustment Operation Strain input channel balance adjustment
set sampling frequency.) is performed using PC, operation switch
Using CAN-41A EDX-200A-4H Max. 24 + Channels of CAN data (panel screen), or dedicated remote
EDX-200A-2H Max. 8 + Channels of CAN data control
EDX-200A-1 Channels of CAN data Recording Data Format Kyowa standard file format KS2
EDX-200A-4T Max. 24 + Channels of CAN data Analysis using optional Data Analysis Software
Digital Filter Butterworth filter (IIR) DAS-200A is possible.
Type of filter: LPF, HPF Data Collection Online using PC, or offline direct reading from
Order of a filter: 1 to 8 CF card to PC
Amplitude ratio at cutoff point: -3dB TEDS Only when using online control from a PC
Attenuation: -6 x N dB/oct. (N is filtering times ) Supported conditioner cards: CDV-40B (-F),
Simultaneously use with built-in LPF possible. DPM-42B (-F), DPM-42B-I (-F), CCA-40A (-F),
Application on CAN data not possible. CDV-44AS, CDA-44AS, CDA-45AS, CVM-41A
Data Recording CF cards, 128 MB to 16 GB (Kyowa recommended items) Power Supply EDX-200A-4H: 10 to 36 VDC
Maximum data file size (Available for data acquisition): EDX-200A-2H: 10 to 36 VDC
4 GB for 1-time measurement EDX-200A-1: 10 to 33 VDC
1 GB for repetitive measurement, 2 times or more EDX-200A-4t: 10 to 36 VDC
Display Channel status display LED: Connector type: RM12BRD-4PH (Hirose)
EDX-200A-2H: 16; EDX-200A-4H/4T: 32; EDX-200A-1: 8 Use DC power supply or AC adapter
Unit status display LED: (Optional accessory)
EDX-200A-2H/4H/4T: 7; EDX-200A-1: 4 Current Consumption EDX-200A-2H: Approx. 1.6 A
Unit status display organic EL monitor: (12 VDC with 2 CDV-40B)
EDX-200A-2H/4H/4T: 1; EDX-200A-1: 0 EDX-200A-4H: Approx. 2.6 A
Operating Switch (12 VDC with 4 CDV-40B)
UP, DOWN :Status display organic EL monitor display switching EDX-200A-4T: Approx. 2.6 A
REC/PAUSE :Start/pause data recording. (12 VDC with 4 CDV-40B)
STOP :Stop data recording. EDX-200A-1: Approx.1.0 A
BAL. :Implement balance (Balance adjustment) (12 VDC with 1 CDV-40B)
LOAD :Read and configure conditions from CF card Operating Temperature 0 to 50°C (EDX-200A-4T: -20 to 65°C)
OPT. :Execute arbitrary configured functions Operating Humidity 20 to 90%RH (Non-condensing)
ID :EDX identifier configuration Storage Temperature -20 to 60°C (EDX-200A-4T: -30 to 70°C)
POWER :Power switch Vibration Resistant
USB/LAN :Communications I/F, switchable 49.0 m/s2 (5 G), 5 to 55 Hz 1 cycle 1 min., each axis 15 cycles (Non-operating)
*No UP, DOWN and ID switches for EDX-200A-1 29.4 m/s2 (3 G), 5 to 55 Hz 1 cycle 1 min., each axis 15 cycles (Operating)
External Control Connector CONT IN, CONT OUT Impact Resistant 196.1 m/s2 (20 G)/11 ms, 294.2 m/s2 for EDX-200A-1
(Remote control, for synchronous operation) Dimensions (Excluding protrusions)
*No CONT OUT for EDX-200A-1 EDX-200A-4H: 165 W × 132.5 H ×255 D mm
Interfaces USB (USB2.0 High Speed) 1 port EDX-200A-2H: 120 W × 132.5 H ×255 D mm
Connector configuration: Series B receptacle EDX-200A-4T: 185.2 W × 142.8 H ×255D mm
LAN (10/100BASE-T) 2 ports EDX-200A-1: 148 W × 53 H × 257 D mm
Data Recorders/Analyzers
(However, LAN OUT is for synchronous operation) Weight (Approx. kg) EDX-200A-4H: 2.1 (2.6 with 4 CDV-40B)
Connector configuration: RJ45 modular jack EDX-200A-2H: 1.8 (2.0 with 2 CDV-40B)
Note: No LAN OUT for EDX-200A-1 EDX-200A-4T: 3.7 (4.2 with 4 CDV-40B)
Synchronous Operation With synchronous cable (N-95) connection, EDX-200A-1: 0.9 (1.1 with 1 CDV-40B)
number of units with synchronous operation: 8 EMC Directive EN61326-1 (Class A) (*Excluding EDX-200A-4T)
With LAN cable connection, number of units with RoHS Directive EN50581 (*Excluding EDX-200A-4T)
synchronous operation: 8
Standard Accessories
*No synchronous operation for EDX-200A-1
Setting Conditions DC power cable P-76 (1.8 m)
USB cable N-38 (1 m)
Online: From the PC via LAN or USB port Ground wire P-72 (5 m)
Offline: By reading from the CF card which has measuring conditions. CF card (1 GB) inserted in the slot
Written with the data acquisition software DCS-100A Fuses (8 A for 4-slot model, 5 A for 2-slot model)
Saving Conditions Recording of conditioner configuration conditions Dummy panel
and measurement conditions within the EDX built- in Installed on the free slots before shipment
EDX-200A-4H: 3 pcs
nonvolatile memory. Immediate start of data collection EDX-200A-2H: 1pc
using the previously configured measurement EDX-200A-4T: None
conditions after power-on is possible. EDX accessory bag
Measuring Modes Manual measurement/trigger measurement/ Dynamic data acquisition software DCS-100A (DVD)
interval measurement Instruction manual (In English & Japanese, in the above DVD)
Manual Measurement Data recording is manually started or stopped Optional Accessories
when data is recorded to a preset number of EDX-200A AC adapter 4H, 4T: UEA360-1540 (For U.S.A.: SPU61A-106 15 V)
measured data. EDX-200A AC adapter 2H, -1: UIA345-12 (For U.S.A.: UNI345-1238)
Manual mode allows recording of voice memo Fixing adapter
during data recording. EDX dummy panel EDX1P-DUMMY
Trigger Measurement Data recording is automatically started when Remote control unit RCU-42A
Battery unit for instantaneous power failure EDB-41B
the preset trigger condition is satisfied. Monitor unit EMON-20A
*No CAN data of CAN-41A is used as Synchronous cables N-95
the trigger condition. N-128
3-58
3
-59
Simplified configuration of the EDX-200A
MEASURING INSTRUMENTS
Data analysis
software
DAS-200A
Strain/voltage/acceleration
PC measurement card
LAN
cable CVM-41A
(Option)
or
USB
cable
(1 m, provided)
Dynamic data
acquisition
software Strain/voltage
measurement card
DCS-100A
CDV-40B(-F)
Video record/
Numeric operation GPS data acquisition
(Option) (Option)
DCS-101A DCS-104A
Data Recorders/Analyzers
Monitor unit
Remote control
unit Dynamic strain
EMON-20A measurement card
EDX-200A DPM-42B(-F)
RCU-42A
(For EDX-5000A, too)
3-59
3
-60
MEASURING INSTRUMENTS
Options for input
CVM Strain-gage
input cable transducers
For voltage/ Input
piezoelectric (Load cell, pressure/
(BNC connector) acceleration/
Bridge box torque transducer, etc.)
U-121,U-122,
U-123
FV-1A Voltage Input
DBS-120B-8
CVM integrated
DBS-350B-8
input cable
Bridge box
Strain gages Input
DBV-120A-8
N-121 DBV-350A-8
Strain-gage
CDV integrated transducers
Voltage input box Input
input cable (Load cell, pressure/
acceleration/
torque transducer, etc.)
VI-8A
Piezoelectric
N-105 acceleration Input
For voltage/ sensors
piezoelectric
Data Recorders/Analyzers
(BNC connector)
Input cable
(8 channels)
Bridge box
U-38 to 48 (Connector type) Strain-gage
transducers
Input
(Load cell, pressure/
DPM integrated acceleration/
input cable torque transducer, etc.)
Bridge box
(Integrated)
N-104
DBS-120B-8
DBS-350B-8
3-60
3
-61
●DCS-100A software for EDX-200A section
(Not included with EDX-200A-4H-0, EDX-200A-2H-0)
*For details of DCS-100A, see page 4-3.
Controllable Units
Interfaces
Data Storage
Max. 8 (Max. 256 channels)
LAN, USB
Measured data is saved to CF card in the EDX
Measurement Conditions for Saving Data in CF Card
Sampling Frequencies 1 Hz to 100 kHz
Data File Size
(1-2-5 series, 2n series, or external clock)
(Depends on the number of measuring channels.
Dual sampling supports)
Max. 4 GB
and/or data folder in the PC in KS2 format. Measuring Modes Manual, manual (Data points preset), interval,
Channel Conditions Measurement ON/OFF, mode, range, analog trigger, external trigger, and composite
LPF, HPF, balance ON/OFF, CAL range, trigger
MEASURING INSTRUMENTS
CAL ON/OFF, calibration coefficient, offset, units, Manual Measurement Measurement is made from a press of the REC
CH name, measuring range, decimal point, button to a press of the STOP button or to
rated capacity, rated output, chk.val.(Up), completion of recording to the preset number
chk.val. (Down), internal calibration ON/OFF, of measurements.
offset ON/OFF, digital filter, sampling frequency Interval Measurement Measurement is made automatically at preset
(Select dual sampling high-speed, low-speed, intervals from the preset starting time.
high-speed + low-speed) Trigger Measurement Start/stop recording based upon specified
(Selection of arbitrary display items possible) trigger conditions. (The trigger standard values
Applicable Optional Cards are set absolute triggers.)
Functions CAN Data Interval Point Zero GPS Data DIO Setting End Trigger Settable
Acquisition Measurement Measurement Acquisition *3
Cards *1 (GPS in sync) (Manual)*1, *2 *1, *2 Delay For both start/stop, max. 262144 data points/
*1, *2
channel
ECAN-40A Yes Yes
(Depending on the number of measuring channels)
ETIM-40A Yes Yes Yes Yes
Analog Trigger
EGPC-40A Yes Yes Yes Yes Yes
Trigger Channels Any channel
*1: When data is saved in CF card
*2: When the card is installed in host EDX Trigger Level Sets in physical quantity.
*3: When control signals are from a remote control unit Trigger Slope Up, down
A. Data is saved in the CF card. External Trigger
B. If synchronous operation, only host EDX is settable.
Trigger Slope Up, down
CAN Data Acquisition Max. 512 channels/unit of CAN data is possible. Composite Trigger Conditions
(CAN data is saved to CF card in the EDX-200A.) Trigger Source Selects from analog channels (Host EDX any
Point Zero Manual Measurement 4 channels), external trigger, and manual trigger
In multiple units of EDX-200A, allows acquisition AND or OR Logic is possible.
to be started at zero second (0 ms) based on clock Trigger Level Sets in physical quantity.
data of GPS satellite. Trigger Slope Up, down
GSP Synchronous Interval Measurement Repetition Acquisition In long-term data acquisition, a specified
Allows multiple units of EDX-200A to be started amount of data (or time) is saved in KS2 file .
acquisition based on clock data of GPS satellite. *Workable in manual mode (Data points preset).
GPS Data Acquisition Monitors and records GPS data such as latitude, Measuring Conditions for Saving Data in Hard Disk of PC
longitude, direction of movement, speed Sampling Frequencies 1 Hz to 100 kHz (1-2-5 series, 2n series,
GPS data is saved to CF card in EDX-200A as or external clock)
NMEA format. Data File Size Capacity of the hard disk
DIO Settings Measurement Mode Manual, manual (Data points preset), interval,
I/O Points Max. 8 and analog trigger
I/O Settings Sets every bit of digital input, digital output, Static Measurement Every time the DCS-100A starts recording data,
and remote-control input. the DCS-100A additionally saves the moving-
averaged measured data in a single CSV format
file in manual and interval modes.
Repetition Acquisition In long-term data acquisition, a specified
Data Recorders/Analyzers
3-61
3
-62
■Dimensions (Handle grip in blue)
MEASURING INSTRUMENTS
EDX-200A-4H (255)
(165)
(132.5)
(138.5)
(148.6)
(140.1)
(265) (173)
(255)
EDX-200A-2H
(120)
(132.5)
(138.5)
(148.6)
(140.1)
(265) (128)
255
EDX-200A-4T
185.2
Data Recorders/Analyzers
(160.1)
142.8
(265)
257
EDX-200A-1
148
(54.4)
53
(265.8) (156)
EDX-200A
Recommended
products for Data Analysis Software
DAS-200A
combination
→ 4-9
3-62