NS-200F Series Manual
NS-200F Series Manual
NS-200F Series Manual
Introduction:
The NS-200F series is an Ethernet (10/100Base-TX) to
Fiber Optic (100Base-FX) converter. The Ethernet
supports 10/100M auto-negotiation feature and auto
MDI/MDI-X function.
Features:
• Automatic MDI/MDI-X crossover for plug-and-play
• Each port supports both 10/100 Mbps speed auto negotiation
• Store-and-forward architecture
• Full duplex IEEE 802.3x and half duplex backpressure flow control
• Supports +10 ~ +30 VDC voltage
• Supports operating temperatures from 0 ℃ ~ +70 ℃
• DIN-Rail mount for industrial usage
Specifications:
Technology
Standards IEEE802.3, 802.3u, 802.3x
Processing Type Store & forward wire speed switching
MAC Addresses 1024
Memory Bandwidth 1.4 Gbps
Interface
10/100BaseT(X) auto negotiation speed, F/H duplex mode,
RJ-45 Port
and auto MDI/MDI-X connection
Fiber Port 100 Base-FX
LED Indicators 10/100M, Link/Act, Full duplex/Half duplex(Fiber Port)
Ethernet Isolation 1500 Vrms 1 minute
Frame Ground for EMS Protection Yes
Multi mode fiber cables: 50/125, 62.5/125 or 100/140 μm
Distance: 2 km, (62.5/125 μm recommended) for full duplex
Wavelength: 1300 or 1310nm
Multi Mode
Min. TX Output: -20 dBm
Max. TX Output: -14 dBm
RX Sensitivity: -34 to -31 dBm
Single-mode fiber cables: 8.3/125, 8.7/125, 9/125 or 10/125
μm
Distance: 15 km, (9/125 μm recommended) for full duplex
Single Mode
Wavelength: 1300 or 1310nm
Min. TX Output: - 15 dBm
Max. TX Output: -8 dBm
RX Sensitivity: -36 to -31 dBm
NS-200F Series User’s Manual (Version 1.5, Nov/2009) --------------- 1
Ethernet: 2-pair UTP/STP Cat.3,4,5, EIA/TIA-568 100-ohm
Ethernet Transmission distance
Fast Ethernet: 2-pair UTP/STP Cat. 5, EIA/TIA-568 100-ohm
Power
Input Voltage Range +10 ~ +30 VDC (Non-isolation)
Power consumption 0.12A@24 VDC, +/- 5% arrowed with 100M Full duplex\
LED Indicator Yes
Protection Power reverse polarity protection
Frame Ground for EMS Protection Yes
Mechanical
Case Plastic (Flammability UL 94V-0)
Dimensions (W x H x D) 33mm x 107mm x 85mm
Installation DIN-Rail
Environmental
Operating Temperature 0°C ~ +70°C
Storage Temperature -20 ~ +85°C
Ambient Relative Humidity 10% ~ 90% HR, non-condensing
LED functions:
Standard RJ45 female connectors are provided. A standard RJ45 plug cable is necessary
to connect your device to the unit since switch that supports auto crossover. Figure1
shows the LED indicator functions. The module includes an internal.
Figure1:
NS-200FC/NS-200FCS NS-200FT
Application Note:
Figure2 shows common media conversion system network topologies. This figure is a
simple end-to-end configuration; it is easy way to verify proper operation of the media
converter(s), assuming that the Network Interface Cards (NIC’s) or Ethernet ports in each
PC/workstation end link partner are properly configured.
Checking Power:
Since the NS-200F Series consumes 2.9W Max, ensure that your power supply is able to
meets this demand. The Input voltage range is between +10 and +30VDC.
External power supply is connected using the removable terminal block as shown below:
Full-duplex ( Default)
Transmission Distance: 2 km
DIP –Switch
Half-duplex
Transmission Distance: 412m
DIP –Switch
Dimensions: