Berridge Shop Drawing Guidelines Checklist
Berridge Shop Drawing Guidelines Checklist
Berridge Shop Drawing Guidelines Checklist
Name and location of project and name ROOF PLAN Vinyl weatherseal
of roofing installer printed on every page
Substructure, open framing purlins,
INSTALLATION INSTRUCTIONS Roof plan shows all roof slopes solid sheathing
Written instructions for the general Berridge panel system(s) called out Underlayment type called out and
handling and installation of panels, on roof plan locations shown
flashing, underlayment and fasteners
(Berridge has produced such Roof plan shows all roof penetrations Additional layers of underlayment
instructions for its roofing systems (plumbing stacks etc.) required at eave, valley, gable, etc.
and with a degree of modification can refer to Berridge typical details
be tailored to meet the requirements of Detail section cuts called out for every
individual projects) detail Flashings and counter flashings
The panel and underlayment requirements will be determined during the Berridge Manufacturing Co.
review of the Architectural drawings. Please refer to these requirements during your production of shop
drawings. Submit (2) sets of shop drawings along with an Application Form for a Berridge Watertightness
Warranty for review and approval.
Shop drawings must show the relationship between the roof panel, panel clips/rib, flashings, fasteners,
underlayment, caulking, penetrations the building, and all areas of the roof.
Technical, Submittals, Procedures, Inspectors, & Training: Pricing, Sales, or Credit Inquiries:
BMC Houston - WTW Department BMC San Antonio - Sales Department
Phone: (800) 231-8127 Phone: (800) 669-0009
Local: (713) 223-4971 Local: (210) 650-3050
Fax: (713) 236-9422 Fax: (210) 650-0379
Email: BMCWatertightDept@Berridge.com Email: Sales@Berridge.com