Nothing Special   »   [go: up one dir, main page]

TDS 01ofg V08 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

HZ Geral 01OFG

PRODUCT APPLICATION
Halogen free flame retardant thermoplastic compound to be used as tight and semitight buffer fibre
cables. This compound combines excellent mechanical properties, -20 to +90ºC and high fire resistance,
with excellent processing conditions. Low shrinkage and good extralength fibre. Good gel and chemical
resistance.

PHYSICAL PROPERTIES UNIT VALUE TOLERANCE TEST METHOD


Density (23±2 ºC) g/cm3 1,44 ± 0,02 ISO 1183 A
Hardness (23±2 ºC) shore D/15s 56 ±2 ISO 868
Tensile strenght (23±2 ºC) M Pa 14 Typical value CEI 60811-1-1
Elongation at break (23±2 ºC) % 170 Typical value CEI 60811-1-1
Elongation after aging % variation 30 max. MI (100ºC - 168h)
Tensile strenght after aging % variation 30 max. MI (100ºC - 168h)
Melt flow index (21,6 Kg/150ºC) g/10' 9 ±3 ISO 1133
Conductivity microS.mm-1 0,8 Typical value EN 50267-2-2
Water Absortion (10d at 70ºC) mg/cm² 0,3 max. CEI 60811-1-3
Pellet Length mm 2,8 max. MI
Heat deformation test (6h, 80ºC) % variation 5 max. Internal method

FLAMMABILITY UNIT VALUE TOLERANCE TEST METHOD


Limiting Oxygen Index % 33 Typical value ASTM D 2863
Halogen Content % 0 Typical value CEI 60754-1
pH pH 4,5 min. EN 50267-2-2

CHEMICAL RESISTANCE UNIT VALUE TOLERANCE TEST METHOD


TS after immersion in oil (IRM 902) % variation -12 max. Oil(IRM 902) - 70ºC-4h
Elong. after immersion in oil (IRM902) % variation -5 max. Oil(IRM 902) - 70ºC-4h

The typical values reported in the table have obtained from measurements made in pressed plates, on extruded samples or pellets.

Color: Natural

Packing: The compound can be supplied in bags of aluminum or polyethylene (of 20 or 25 kg), in big bags (of 750 the 2000 kg).

Storage: The product must be stored at room temperature between 10 and 50ºC and relative humidity less then 70%.
The container must be kept tightly closed to prevent moisture absorption or contamination.
The container must be kept in a dry cool and well ventilated place. Avoid direct sun light and direct heat exposure.
Maximum recommended storage time in the original package and without being open: 9 months from the delivery date. We
recomend always to dry the compound before use.

CABOPOL - Polymer Compounds, S.A. Telf. +351 244 498 151 Nº 5106
Apartado 39 EC Porto de Mós Fax: +351 244 481 970 Version 08
2481-917, Porto de Mós, Portugal cabopol@mekkin.pt Date 11/06/2019

MOD.CTC/05
PROCESSING GUIDE
Extrusion line L/D 24D-25D
Color masterbatch PE, EVA base
Wire section (sqm)
Tooling Pressure DDR 1,6; lip diameter +1,5/1 mm core.
Semi-pressure or a tube DDR 1,5 - 2; DRB=1
Die diameter Die same diameter as outer or -0,2mm
Screw design compression ratio Low compression 1.1,5 with flat end trnsport. High compression also
possible need adjust temperature profile increase temperature.
Screw cooling Not mandatory, if possible 120ºC
Copper heating (ºC) Not mandatory or 80ºC- 100ºC
Pre-dry material before extrusion Not mandatory if time after production < 3 months
Moisture level (ppm) < 600
Cooling Water Ambient water cooling
Screen packs 40, 60 mesh or free flow open ring
Extruder Z1(°C) 130-140
Extruder Z2(°C) 140-150
Extruder Z3(°C) 155
Extruder Z4(°C) 160
Neck Z5(°C) 160
Head Z6(°C) 165-170
Die Z7(°C) 175
Melt temperature (°C) 155-165
Speed extrusion (m/min) 300m/min D 3,0 mm;100m/min D 20mm
Surface If not smooth with die droll, use flame to improve
Notes Screw design halogen free - low compression; control temperature as better
as possible but not mandatory. Adjust temperatures base on L/D and
number of zones. Porosity come for the shear or moisture control melt not to
pass 175ºC.

Disclaimer
Once removed from its original package, the material shall be used immediately. Cabopol, SA assumes no responsibility for any non-
conformities of the material resulting from its incorrect storage and/or handling.

All values expressed in this data sheet were obtained under controlled conditions according to our knowledge and are valid only for those same
conditions. Therefore, the information contained in this document is believed to be accurate and reliable. However, no warranty, expressed or
implied, is given as to the suitability, accuracy, reliability or completeness of the information made available. The information provided herein
does not hold Cabopol liable for damages or penalties resulting from following our suggestions or recommendations, and it is the responsibility
of the user to ensure of the conformity of the material to the intended application and to the specific regulations that apply to each case.

This document contains confidential and / or privileged information. If you are not the intended recipient or the person authorized to receive this
document, you should not use, copy or disclose any information contained therein or take any action based on this information.

CABOPOL - Polymer Compounds, S.A. Telf. +351 244 498 151 Nº 5106
Apartado 39 EC Porto de Mós Fax: +351 244 481 970 Version 08
2481-917, Porto de Mós, Portugal cabopol@mekkin.pt Date 11/06/2019

MOD.CTC/05

You might also like